Coaxial Cable Specifications

Time Delay
(ns/ft)

Dielectric Type
Solid Polyethylene (PE)
Foam Polyethylene (FE)
Foam Polystyrene (FS)
Air Space Polyethylene (ASP)
Solid Teflon (ST)
Air Space Teflon (AST)

1.54
1.27
1.12
1.15-1.21
1.46
1.13-1.20

Propagation
Velocity
(% of c)
65.9
80.0
91.0
84-88
69.4
85-90

Properties for popular coaxial cables are listed below.


c = speed of light in vacuum
Type (/U)
RG-4
RG-5
RG-5A/B
RG-6
RG-6A
RG-8
RG-8A
RG-9
RG-9A
RG-9B
RG-10
RG-10A
RG-11
RG-11A
RG-12
RG-12A
RG-17A
RG-22
RG-22A/B
RG-23/A
RG-24/A
RG-34
RG-34A
RG-35
RG-35A/B
RG-55B
RG-58
RG-58A
RG-58B

MIL-W-17

/2-RG6
/2-RG6

/6-RG11
/6-RG11
/6-RG12
/6-RG12
/15-RG22
/15-RG22
/16-RG23
/16-RG24
/24-RG34
/24-RG34
/64-RG35
/64-RG35
/28-RG58
/28-RG58

Dielectric
Type

Z0()
50.0
52.5
50.0
76.0
75.0
52.0
52.0
51.0
51.0
50.0
52.0
52.0
75.0
75.0
75.0
75.0
52.0
95.0
95.0
125.0
125.0
71.0
75.0
71.0
75.0
53.5
53.5
52.0
53.5

PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE

Capacitance
(pF/ft)
30.8
28.5
30.8
20.0
20.6
29.6
29.6
30.2
30.2
30.8
29.6
29.6
20.6
20.6
20.6
20.6
29.6
16.3
16.3
12.0
12.0
21.7
20.6
21.7
20.6
28.8
28.8
29.6
28.8

O.D.
(in.)
0.226
0.332
0.328
0.332
0.332
0.405
0.405
0.420
0.420
0.420
0.463
0.463
0.405
0.405
0.463
0.463
0.870
0.405
0.420
0.650
0.708
0.625
0.630
0.928
0.928
0.200
0.195
0.195
0.195

dB/100 ft
@400 MHz
11.7
7.0
6.5
7.4
6.5
6.0
6.0
5.9
6.1
6.1
6.0
6.0
5.7
5.2
5.7
5.2
2.8
10.5
10.5
5.2
5.2
5.3
5.3
2.8
2.8
11.7
11.7
13.2
14.0

Vmax
(rms)
1,900
3,000
3,000
2,700
2,700
4,000
5,000
4,000
4,000
5,000
4,000
5,000
4,000
5,000
4,000
5,000
11,000
1,000
1,000
3,000
3,000
5,200
6,500
10,000
10,000
1,900
1,900
1,900
1,900

Shield
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid

RG-58C
RG-59/A
RG-59B
RG-62/A/B
RG-63/A/B
RG-65/A
RG-71/A/B
RG-79/A/B
RG-83
RG-88
RG-108/A
RG-111/A
RG-114/A
RG-119
RG-120
RG-122
RG-130
RG-131
RG-133/A
RG-141/A
RG-142/A/B
RG-144
RG-164
RG-165
RG-166
RG-174
RG-177
RG-178/A/B
RG-179
RG-179A/B
RG-180
RG-180A/B
RG-210
RG-211/A
RG-212
RG-213
RG-214
RG-215
RG-216
RG-217
RG-218
RG-219
RG-223
RG-302
RG-303
RG-304
RG-307/A
RG-316
RG-391
RG-392

/28-RG58
/29-RG59
/29-RG59
/30-RG62
/31-RG63
/34-RG65
/90-RG71
/31-RG79

/45-RG108
/15-RG111
/47-RG114
/52-RG119
/52-RG120
/54-RG122
/56-RG130
/56-RG131
/100-RG133
/60-RG142
/62-RG144
/64-RG164
/65-RG165
/65-RG166
/67-RG177
/93-RG178
/94-RG179
/94-RG179
/95-RG180
/95-RG180
/97-RG210
/72-RG211
/73-RG212
/74-RG213
/75-RG214
/74-RG215
/77-RG216
/78-RG217
/79-RG218
/79-RG219
/84-RG223
/110-RG302
/111-RG303
/112-RG304
/116-RG307
/113-RG316
/126-RG391
/126-RG392

50.0
73.0
75.0
93.0
125.0
950.0
93.0
125.0
35.0
48.0
78.0
95.0
185.0
50.0
50.0
50.0
95.0
95.0
95.0
50.0
50.0
75.0
75.0
50.0
50.0
50.0
50.0
50.0
70.0
75.0
93.0
95.0
93.0
50.0
50.0
50.0
50.0
50.0
75.0
50.0
50.0
50.0
50.0
75.0
50.0
50.0
75.0
50.0
72.0
72.0

PE
PE
PE
ASP
ASP
ASP
ASP
ASP
PE
PE
PE
ASP
ST
ST
PE
PE
PE
PE
ST
ST
ST
PE
ST
ST
PE
ST
ST
ST
ST
ST
ASP
ST
PE
PE
PE
PE
PE
PE
PE
PE
PE
ST
ST
ST
80
ST

30.8
21.1
20.6
13.5
10.0
44.0
13.5
10.0
44.0
50.0
19.7
16.3
6.5
29.4
29.4
30.8
17.0
17.0
16.3
29.4
29.4
19.5
20.6
29.4
29.4
30.5
30.8
29.4
20.9
19.5
15.4
15.4
13.5
29.4
29.4
30.8
30.8
30.8
20.6
30.8
30.8
30.8
19.8
19.5
29.4
29.4
16.9
29.4
23.0
23.0

0.195
0.242
0.242
0.242
0.405
0.405
0.245
0.436
0.405
0.515
0.235
0.478
0.405
0.465
0.523
0.160
0.625
0.683
0.405
0.190
0.195
0.410
0.870
0.410
0.460
0.110
0.895
0.072
0.100
0.100
0.140
0.140
0.242
0.730
0.332
0.405
0.425
0.463
0.425
0.545
0.870
0.928
0.211
0.201
0.170
0.280
0.270
0.102
0.405
0.475

14.0
10.5
9.0
8.0
5.5
16 @5MHz
8.0
5.5
9.0
0.7 @1MHz
2.8 @10MHz
10.5
8.5
3.8
3.8
18.0
8.8
8.8
5.7
9.0
9.0
4.5
2.8
5.0
5.0
14.7
2.8
29.0
21.0
21.0
17.0
17.0
8.0
2.3
6.5
5.5
5.5
5.5
5.2
4.3
2.5
2.5
8.8
8.0
9.0
6.0
7.5
20.0
15.0
15.0

1,900
2,300
2,300
750
1,000
1,000
750
1,000
2,000
10,000
1,000
1,000
1,000
6,000
6,000
1,900
3,000
3,000
4,000
1,900
1,900
5,000
10,000
5,000
5,000
11,000
1,000
1,200
1,200
1,500
1,500
750
7,000
3,000
5,000
5,000
5,000
5,000
7,000
11,000
11,000
1,900
2,300
1,900
3,000
1,000
1,200
5,000
5,000

Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Dbl Braid
Braid
Braid
Braid
Braid
Braid
Dbl Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid

RG-393
RG-400
RG-401
RG-402
RG-403
RG-405
9914 (Belden)

/127-RG393
/128-RG400
/129-RG401
/130-RG402
/131-RG403
/133-RG405

50.0
50.0
50.0
50.0
50.0
50.0
50.0

ST
ST
ST
ST
ST
ST

29.4
29.4
29.4
29.4
29.4
29.4
26.0

0.390
0.195
0.250
0.141
0.116
0.086
0.405

5.0
9.6
4.6
7.2
29.0
13.0
10.0

Common Coaxial Cables

5,000
1,900
3,000
2,500
2,500
1,500
------

Braid
Braid
Cu. S-R
Cu. S-R
Braid
Cu. S-R

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

shield
s

max
comments

attenuation
@ 750 MHz

Low loss at high


frequency for cable
RG-6/U

75

1.0 mm

PF

0.75

0.185

4.7

0.270

6.86

double

television,satellite

05.65dB/100 ft

television and cable


modems

This is "quad shield RGRG-6/UQ

75

PF

0.298

7.57

quad

6". It has four layers


ofshielding; regular RG-

05.65dB/100 ft

[1

5]

6 has only one or two

Low loss at high


frequency for cable
RG-7

75

1.30 mm

PF

0.225

5.72

0.320

8.13

double

television,satellite

04.57dB/100 ft

television and cable


modems

RG-8/U

50

2.17 mm

PE

RG-8X

50

1.0 mm

PF

0.75

0.285

7.2

0.405

10.3

0.185

4.7

0.242

6.1

Amateur radio; Thicknet


(10BASE5) is similar

double

A thinner version, with


the electrical

05.967
dB/100 ft

[16]

10.946

Common Coaxial Cables

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

shield
s

max
comments

attenuation
@ 750 MHz

characteristics of RG-8U

dB/100 ft

[16]

in a diameter similar to
RG-6.

RG-9/U

51

RG-11/U

75

RG-56/U

48

PE

1.63 mm

PE

0.66

0.285

7.2

1.4859 m

0.420

10.7

0.412

10.5

[17]

Triple/Qua Used for long drops and


d

underground conduit

[18]

03.65dB/100 ft

0.535 13.589 Dual/Quad Cable TV installations

Used for
radiocommunication
and amateur radio, thin
RG-58/U

50

0.81 mm

PE

0.66

0.116

2.9

0.195

5.0

single

Ethernet (10BASE2)
and NIMelectronics,
Loss 1.056 dB/meter @
2.4 GHz. Common.

[19]

13.104
dB/100 ft

[16]

Common Coaxial Cables

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

shield
s

max
comments

attenuation
@ 750 MHz

Used to
carry baseband video
in closed-circuit
television, previously
RG-59/U

75

0.81 mm

PE

0.66

0.146

3.7

0.242

6.1

single

used for cable television.


In general, it has poor
shielding but will carry
an HQ HD signal or
video over short
distances.

[20]

Used to carry television,


3C-2V

75

0.50 mm

PE

0.85

3.0

5.4

single

video observation
systems, and other. PVC
jacket.

Used for interior lines for


5C-2V

75

0.80 mm

PE

0.82 +/-2

0.181

4.6

0.256

6.5

double

monitoring system,
CCTV feeder lines,
wiring between the
camera and control unit

09.708
dB/100 ft

[16]

Common Coaxial Cables

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

shield
s

max
comments

attenuation
@ 750 MHz

and video signal


transmission. PVC
jacket.

Used for high-definition


RG-60/U

50

1.024 mm

PE

0.425

10.8

single

cable TV and highspeed cable Internet.

Used for ARCNET and


RG-62/U

92

PF

0.84

0.242

6.1

single

automotive radio
antennas.

RG-62A

93

RG-142

50

RG-174/U

50

ASP

7x0.16 m
m

PE

0.242

0.66

0.059

1.5

0.100

[21]

6.1

single

Used for NIM electronics

4.95

double

RG-142.pdf

2.55

single

Common for wifi pigtails:


more flexible but higher

23.565
dB/100 ft

[16]

Common Coaxial Cables

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

shield
s

max
comments

attenuation
@ 750 MHz

loss than RG58; used


with LEMO 00
connectors
in NIM electronics.

70.1 mm
RG-178/U

50

(Ag-plated
Cu-clad

PTFE

0.69

0.033

0.84

0.071

1.8

single

PTFE

0.67

0.063

1.6

0.098

2.5

single

Used for high-frequency


signal transmission.

Steel)

70.1 mm
RG-179/U

75

(Ag-plated

[24]

VGA RGBHV

Cu)

0.0120 in
RG180B/U

95

(Ag-plated
Cu-clad
steel)

single Ag
PTFE

0.102

2.59

0.145

3.68

covered
Cu

VGA RGBHV

[22]

42.7 dB/100 ft
[23]

@ 900 MHz

Common Coaxial Cables

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

shield
s

max
comments

attenuation
@ 750 MHz

For radiocommunication
RG-213/U

50

70.0296
in Cu

and amateur radio, EMC


PE

0.66

0.285

7.2

0.405

10.3

single

test antenna cables.


Typically lower loss than
RG58. Common.

RG-214/U

50

70.0296
in

PE

0.66

0.285

7.2

0.425

10.8

double

05.967
dB/100 ft

[16]

[25]

Used for high-frequency


signal transmission.

[26]

06.702
dB/100 ft

[16]

Large diameter, not very


RG-218

50

0.195 in
Cu

PE

0.66

0.660

16.76

(0.680?)

(17.27?)

flexible, low loss


0.870

22

single

(2.5dB/100' @
400 MHz), 11kV

02.834
dB/100 ft

[16]

dielectric withstand.

Silver-plated
RG-223/U

50

0.88 mm

PE

0.66

0.0815

2.07

0.212

5.4

double

shields. Sample RG-223


Datasheet

11.461
dB/100 ft

[16]

Common Coaxial Cables

impedanc
type

core

ohms

RG-316/U

RG-400/U

50

50

7x0.0067
in

19x0.20m
m

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

max

shield

comments

attenuation
@ 750 MHz

used with LEMO 00


PTFE

0.695

0.060

1.5

0.098

2.6

single

connectors
in NIMelectronics;

PTFE

2.95

4.95

double

[27]

[28]

22.452
dB/100 ft

[16]

12.566
dB/100 ft

[16]

lower loss at high


H155

50

19 x
0.28 mm

0.79

5.4

frequency for
radiocommunication
and amateur radio

low loss at high


H500

50

frequency for

0.82

radiocommunication
and amateur radio

LMR-100

50

2.79

low loss
communications, 1.36

20.725

Common Coaxial Cables

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

max

shield

comments

attenuation
@ 750 MHz

dB/meter @ 2.4 GHz

dB/100 ft

[16]

low loss
communications, 0.620
LMR-195

50

4.95

dB/meter @
2.4 GHz LMR195specs.

10.125
dB/100 ft

[16]

pdf

LMR-200
HDF-200

50

CFD-200

LMR-240

50

LMR-400
HDF-400
CFD-400

1.12 mm
Cu

1.42 mm
Cu

low loss
PF

0.83

0.116

2.95

0.195

4.95

dB/meter @ 2.4 GHz

Amateur radio, low loss


PF

0.84

0.150

3.81

0.240

6.1

(Cu-clad
Al)

double

replacement for RG-

low loss
PF

0.85

0.285

7.24

0.405

10.29

09.035
dB/100 ft

communications, 0.223
[30]

dB/meter @ 2.4 GHz

[16]

06.877
dB/100 ft

[29]

8X

2.74 mm
50

communications, 0.554

[16]

03.544
dB/100 ft

[16]

Common Coaxial Cables

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

shield
s

4.47 mm
LMR-600

50

(Cu-clad

LMR-900

LMR-1200

LMR-1700

QR-320

50

50

50

75

(BC tube)

8.86 mm
(BC tube)

13.39 mm
(BC tube)

1.80 mm

comments

PF

0.87

0.455

11.56

0.590

14.99

communications, 0.144
dB/meter @ 2.4 GHz

low loss
PF

0.87

0.680

17.27

0.870

22.10

communications, 0.098
dB/meter @ 2.4 GHz

low loss
PF

0.88

0.920

23.37

1.200

30.48

communications, 0.075
dB/meter @ 2.4 GHz

low loss
PF

0.89

1.350

34.29

1.670

42.42

communications, 0.056
dB/meter @ 2.4 GHz

PF

0.395

10.03

single

attenuation
@ 750 MHz

low loss

Al)

6.65 mm

max

Low loss line, which


replaced RG-11 in most

02.264
dB/100 ft

[16]

01.537
dB/100 ft

[16]

01.143
dB/100 ft

[16]

0.844
dB/100 ft

[16]

03.34dB/100 ft

Common Coaxial Cables

impedanc
type

core

ohms

Dielectri

Dielectri

Dielectri

Dielectri

c Type

c VF

c in

c mm

OD

in

shield
s

max
comments

attenuation
@ 750 MHz

applications

QR-540

75

3.15 mm

PF

0.610

15.49

single

Low loss hard line

01.85dB/100 ft

QR-715

75

4.22 mm

PF

0.785

19.94

single

Low loss hard line

01.49dB/100 ft

QR-860

75

5.16 mm

PF

0.960

24.38

single

Low loss hard line

01.24dB/100 ft

QR-1125

75

6.68 mm

PF

1.225

31.12

single

Low loss hard line

01.01dB/100 ft

RG Cable type Specifications


Type

Conductor

Dia.
Over
Ins.

Braid Shield
Inner

Outer

Nom.
O.D.

Jacket
Material

Nom.
Imped.

Nominal
Capacitance

Nominal
Attenuation

ohm

pF/m

dB/km

No./mm

MTRL

mm

No./mm

No./mm

mm

RG-5/U

1/1.29

BC

4.7

16/9/0.16

16/9/0.16

8.4

PVC

52.5

93.5

85

RG-7/U

1/0.914

BC

6.35

24/7/0.18

9.4

PVC

94.5

41

66

RG-8/U

7/0.724

BC

7.24

24/8/0.18

10.3

PVC

52

96.8

69

RG-8A/U

7/0.724

BC

7.24

24/8/0.18

10.3

NC.PVC

52

96.8

69

RG-11/U

7/0.404

TC

7.24

24/8/0.18

10.3

PVC

75

67.3

76

RG-11A/U

7/0.404

TC

7.24

24/8/0.18

10.3

NC.PVC

75

67.3

76

RG-13/U

7/0.404

TC

7.11

24/9/0.16

24/8/0.16

10.7

PVC

74

67.3

76

RG-13A/U

7/0.404

TC

7.11

24/9/0.16

24/8/0.16

10.7

NC.PVC

74

67.3

76

RG-14/U

1/2.59

BC

9.4

24/10/0.18

24/8/0.18

13.8

PVC

52

96.8

46

RG-14A/U

1/2.59

BC

9.4

24/10/0.18

24/8/0.18

13.8

NC.PVC

52

96.8

46

RG-15/U

1/1.45

CCS

9.4

24/10/0.18

24/8/0.18

13.8

PVC

76

65.6

49

RG-17/U

1/1.478

BC

17.3

24/14/0.26

22.1

PVC

52

96.8

28

RG-17A/U

1/4.78

BC

17.3

24/14/0.26

22.1

NC.PVC

52

96.8

28

RG-19/U

1/6.35

BC

23.1

36/12/0.26

28.5

PVC

52

96.8

22

RG-19A/U

1/6.35

BC

23.1

36/12/0.26

28.5

NC.PVC

52

96.8

22

RG-22/U

7/0.386*2C

BC

7.24

24/8/0.18

10.3

PVC

95

52.5

118

RG-22A/U

7/0.386*2C

BC

7.24

24/8/0.16

24/8/0.16

10.7

PVC

95

52.5

118

RG-22B/U

7/0.386*2C

BC

7.24

24/8/0.16

24/8/0.16

10.7

NC.PVC

95

52.5

118

RG-29/U

1/0.813

BC

2.95

16/7/0.127

4.7

PE

53.52.5

93.5

138

RG-34/U

7/0.724

BC

11.6

24/9/0.16

15.9

PVC

713

70.5

46

RG-34B/U

7/0.632

BC

11.7

24/10/0.18

16

NC.PVC

753

67

48

RG-54A/U

7/0.385

BC

4.52

16/9/0.16

6.1

PE

582.5

85.8

187

HG-55/U

1/0.813

BC

2.9

16/7/0.127

16/7/0.127

PE

53.52.5

93.6

138

RG-58/U

1/0.813

BC

2.95

16/7/0.127

4.95

PVC

53.52.5

93.5

138

RG-58A/U

19/0.18

TC

2.95

16/7/0.127

4.95

PVC

502

93.5

174

RG-58C/U

19/0.18

TC

2.95

16/7/0.127

4.95

NC.PVC

502

93.5

174

RG-59/U

1/0.643

CCS

3.71

16/7/0.16

6.15

PVC

733

68.9

125

RG-59A/U

1/0.643

CCS

3.71

16/7/0.16

6.15

NC.PVC

733

68.9

125

RG-59B/U

1/0.584

CCS

3.71

16/7/0.16

6.15

NC.PVC

753

68.9

112

RG-62/U

1/0.643

CCS

3.71

16/7/0.16

6.15

PVC

93

44.3

102

RG-62A/U

1/0.643

CCS

3.71

16/7/0.16

6.15

NC.PVC

935

44.3

102

RG-63/U

1/0.643

CCS

7.24

24/8/0.18

10.3

PVC

125

32.8

66

RG-63B/U

1/0.643

CCS

7.24

24/8/0.18

10.3

NC.PVC

1256

32.8

66

RG-71/U

1/0.643

CCS

3.71

16/7/0.16

16/9/0.127

6.4

PE

93

44.3

102

RG-89/U

1/0.643

CCS

7.24

16/12/0.18

16

PVC

125

32.8

66

RG-108/U

7/0.32*2C

TC

1.84

16/6/0.127

6.2

NC.PVC

786.5

74.3

RG-108A/U

7/0.32*2C

TC

2.01

16/6/0.127

5.97

NC.PVC

787

74.3

RG-122/U

27/0.127

TC

2.44

16/6/0.127

4.06

NC.PVC

502

105

195

RG-130/U

7/0.724*2C

BC

12

24/8/0.26

15.9

PVC

955

56

99

RG-133A/U

1/0.645

BC

7.2

24/8/0.18

10.3

NC.PVC

95

53

76

RG-164/U

1/2.65

BC

17.3

24/14/0.26

22.1

NC.PVC

753

67

30

RG-213/U

7/0.752

BC

7.24

24/8/0.18

10.3

NC.PVC

502

100

69

RG-216/U

7/0.404

TC

7.24

24/9/0.16

24/8/0.16

10.8

NC.PVC

753

67

88

RG-217/U

1/2.69

BC

9.4

24/10/0.18

24/8/0.18

13.8

NC.PVC

502

100

50

COAX TYPE

CHARACTERISTIC

OUTSIDE

VELOCITY

ATTEN

ATTEN

IMPEDANCE

DIAMETER

FACTOR

@ 100 MHZ

@ 1000 MHZ

RG5/U

52.5

8.4

0.66

1.0

3.8

RG6A/U

75

8.4

0.66

1.0

3.7

RG9/U

51.0

10.7

0.66

0.66

2.4

RG10A/U

50

12.1

0.66

0.66

2.6

RG11A/U

75

10.3

0.66

0.76

2.6

RG12A/U

75

12.1

0.66

0.76

2.6

RG20A/U

50

30.4

0.66

0.22

1.2

RG22

95

10.7

0.75

1.5

RG23

125

24.0

0.52

2.0

RG24

125

25.5

0.52

2.0

RG34

75

16.0

0.46

1.8

RG58C/U

50

5.0

0.66

1.8

7.6

RG59B/U

75

6.1

0.66

1.2

4.6

RG62A/U

93

6.1

0.84

0.9

2.8

RG63

125

10.3

0.6

2.1

RG79

125

12.1

0.6

2.1

RG108

78

6.0

1.1

3.8

RG111

95

12.1

0.75

2.6

RG114

185

10.3

1.1

3.8

RG119

50

11.8

0.5

1.8

RG120

50

13.3

0.5

1.8

RG122

50

4.1

1.7

5.5

COMMENTS

COAX TYPE

CHARACTERISTIC

OUTSIDE

VELOCITY

ATTEN

ATTEN

COMMENTS

IMPEDANCE

DIAMETER

FACTOR

@ 100 MHZ

@ 1000 MHZ

RG213/U

50

10.3

0.66

0.62

2.6

Polythene dielectric

RG214/U

50

10.8

0.66

0.76

2.9

Double screened, silver plated


copper wire

RG223/U

50

5.5

0.66

1.58

5.4

UR43

50

0.66

1.3

4.46

UR57

75

10.2

0.66

0.63

2.3

Similar to RG11A/U

UR67

50

10.3

0.66

0.66

2.52

Similar to RG213/U

UR74

51

22.1

0.66

0.33

1.4

UR76

51

0.66

1.7

7.3

UR77

75

22.1

0.66

0.33

1.4

UR79

50

21.7

0.96

0.17

0.6

UR90

75

6.1

0.66

1.2

4.1

Similar to RG58C/U

Similar to RG59B/U

Electrical Characteristics:
Maximum frequencies are those as referenced on individual slant sheets of the MIL-C-17 specification. No values are given for unswept constructions
as the specification recommends these cables should not be used above 400 MHz. All figures referenced above are nominal unless otherwise specified.

Attenuation (dB/100ft) @
M17 Number Impedance Capacitance Max Voltage 100 MHz 400 MHz 1 GHz 2.4 GHz 5 GHz 10 GHz Max Frequency
(ohms) (pF/ft) Typ / Max Typ / Max Typ / Max Typ / Max Typ / Max Typ / Max (GHz)
M17/60-RG142 50 +/- 2 29.4 1900 4.0 / 5.5 8.1 / 11.7 13.4 / 19.2 21.3 / 30.4 33.3 / 48.7 - 17.4
M17/76-RG217 50 +/- 2 30.8 7000 1.5 / 1.6 3.5 / 3.7 6.7 / 7.0 - - - 3.0
M17/93-RG178 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0
M17/93-00001 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0
M17/94-RG179 75 +/- 3 19.4 1200 8.0 / 9.2 15.5 / 21.0 26.7 / 30.7 - - - M17/95-RG180 95 +/- 5 17.4 1500 5.7 / 6.6 11.7 / 17.4 19.2 / 23.0 - - - M17/110-RG302 75 +/- 3 19.4 2300 - 7.2 / 8.0 - - - - M17/111-RG303 50 +/- 2 29.4 1900 3.5 / 3.9 7.2 / 8.0 13.5 / 15.0 - - - M17/112-RG304 50 +/- 2 29.4 3000 2.4 / 2.7 5.8 / 6.4 10.0 / 11.1 - - - 8.0
M17/113-RG316 50 +/- 2 29.4 1200 7.6 / 11.0 16.0 / 21.0 26.2 / 38.0 41.2 / 55.4 - - 3.0
M17/127-RG393 50 +/- 2 29.4 2500 2.3 / 2.5 4.4 / 5.0 7.7 / 9.2 12.4 / 14.2 21.3 / 26.8 30.1 / 37.9 11.0
M17/128-RG400 50 +/- 2 29.4 1900 4.3 / 4.5 8.6 / 10.5 14.1 / 18.1 22.6 / 30.2 35.6 / 52.1 61.6 / 78.0 12.4
M17/131-RG403 50 +/- 2 29.4 1000 - 33.3 / 37.0 - - - - 10.0
M17/152-00001 50 +/- 2 29.4 1200 8.1 / 11.5 17.8 / 24.0 29.6 / 40.0 43.1 / 58.3 100.0 /110.0 153.0/170.0 12.4
M17/158-00001 50 +/- 2 29.4 1900 - 8.1 / 9.5 - - - M17/165-00001 50 +/- 2 29.4 7000 - 3.5 / 3.7 - - - M17/169-00001 50 +/- 2 29.4 1000 - 27.2 / 29.0 - - - - M17/170-00001 50 +/- 2 29.4 1900 - 7.7 / 8.6 - - - - M17/172-00001 50 +/- 2 29.4 1200 - 15.5 / 21.0 - - - - M17/174-00001 50 +/- 2 29.4 2500 - 4.4 / 5.0 - - - - M17/175-00001 50 +/- 2 29.4 1900 - 8.6 /10.5 - - - - M17/176-00001 77 +/- 7 19.0 1000 - - - - - - PTFE Tape Wrap Jacketed RG Cables
RG 187 A/U 75 +/- 3 19.4 1200 - 15.5 / 21.0 - - - RG 188 A/U 50 +/- 2 29.4 1200 7.6 / 11.0 16.0 / 21.0 26.2 / 38.0 41.2 / 55.4 - - 3.0
RG 195 A/U 95 +/- 5 17.4 1500 - 11.7 / 17.4 - - - RG 196 A/U 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0

COAXIAL CABLE SPECIFICATIONS


MAJOR TYPES
DATA SHEET COMPILED BY PAUL HARDEN NA5N
COAX
TYPE

50 Ohm
RG-8
RG-8*
RG-8A
RG-9*
RG-58
RG-58A
RG-58A*
RG-58C
RG-141#
RG-174
RG-223#
9913
72 Ohm
RG-11
RG-11A
RG-59
RG-59*
RG-59B

CONDUCTOR

INSULATION

Strands Diameter Material Diameter

SHIELD
Cover

JACKET

Material Diameter

7/19
7/19
7/21
7/21
Solid
19/33
7/28
19/33
Solid
7/34
Solid
Solid

0.108
0.108
0.085
0.86
0.32
0.35
0.37
0.35
0.037
0.019
0.035
0.108

FP
FP
PE
PE
PE
PE
PE
PE
TF
PE
PE
FP

0.285
0.285
0.285
0.280
0.116
0.116
0.114
0.116
0.116
0.060
0.116
0.285

97%
*96%
97%
*96%
95%
96%
*96%
96%
#96%
88%
#*97%
100%

PE
PE
NC
NC
PV
PV
PV
NC
FG
PV
NC
PV

0.405
0.480
0.405
0.420
0.193
0.195
0.240
0.195
0.190
0.101
0.212
0.405

Solid
7/26
Solid
Solid
Solid

0.064
0.048
0.023
0.032
0.023

FP
PE
PE
FP
PE

0.285
0.285
0.146
0.143
0.146

95%
97%
95%
*96%
95%

PV
PV
PV
PE
NC

0.405
0.405
0.146
0.315
0.242

Velocity Factor pf/ft. Atten/100ft


.
0.78
26
0.5db
0.78
26
0.5db
0.66
30
0.5db
0.66
30
0.6db
0.66
29
1.2
0.66
31
1.4db
0.66
31
1.5db
0.66
31
1.4db
0.70
29
1.1db
0.66
31
3.3db
0.66
31
1.2db
0.84
24
0.4db
0.78
0.66
0.66
0.78
0.66

17
21
21
17
21

0.4db
0.7db
1.1db
1.0db
1.1db

* = Double shielded Coax


1.
2.
3.
4.
5.
6.
7.

# = Silver plated centre conductor and shield

1. Centre conductor is copper or tinned copper except where indicated by #


2. Insulation dielectric Codes PE: Polyethylene FP: Foam Polyethylene TF: High Temperature Teflon
3. Jacket Material Codes PE: Polyethylene PV: PVC NC: Non-contaminating FG: Fiberglass
4. VF = Velocity factor of coax (eg 0.66 = 66%)
5. pf/ft = Capacitance (in pf) per foot
6. Attenuation/100ft = coax attenuation per 100ft at 10Mhz
7. Diameters for centre conductor, insulation and jacket are used for selecting proper connector (BNC,
PL259, etc)

Catalog
No.

RG/U
No.

Nom.
Imp.

Type

Dielect.
Mat.

Cap.

Jacket

Size (in)
and
Type of
Inner
Cond.

Overall
Diameter

Shield

N/A

Waveguide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Waveguide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

0.226
in
5.74
mm

N/A

PVC-I

2
BC

0.226
in
5.74
mm

0.0320 BC

0.332
in
8.43
mm

0.0508 BC

0.328
in
8.33

0.0508 S

N/A

Waveguide

N/A

N/A

N/A

N/A

5074

Coax
Cable

50

30.0
pF/ft
98.4
pF/m

5075

Coax
Cable

52.5

28.5
pF/ft
93.5
pF/m

PE

PVC-I

2
BC

5A

5075A

Coax
Cable

50

30.8
pF/ft
101

PE

PVC-II

2S

PE

5B*

5075B

Coax
Cable

pF/m

mm

50

30.8
pF/ft
101
pF/m

2S

0.338
in
8.59
mm

0.0508 S

PVC-II

BCS

0.332
in
8.43
mm

0.0285
CW

PVC-IIA

BCS

0.332
in
8.43
mm

0.0285
CW

BC

0.370
in
9.40
mm

0.0359 BC

0.405
in
10.3
mm

7/21 BC

PE

5076

Coax
Cable

75

22.0
pF/ft
72.2
pF/m

6A*

5076A

Coax
Cable

75

22.0
pF/ft
72.2
pF/m

PE

Air
space
PE

5077

Coax
Cable

95

12.5
pF/ft
41.0
pF/m

5078

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

8A*

5078A

Coax
Cable

52

29.5
pF/ft

PE

PVC-IIA

PVC-I

PE

PVC-I

BC

PE

PVC-IIA

BC

0.405
in

7/21 BC

96.8
pF/m

5079

Coax
Cable

50

30.0
pF/ft
98.4
pF/m

9A

5079A

Coax
Cable

50

30.0
pF/ft
98.4
pF/m

9B*

5079B

Coax
Cable

50

30.0
pF/ft
98.4
pF/m

10

50710

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

10A*

50710A

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

10.3
mm

PE

PE

PVC-II

PVC-II

PE

PVC-IIA

PE

PVC-II
w/armor

PE

PVC-IIA
w/armor

BCS

0.420
in
10.7
mm

7/21 S

2S

0.420
in
10.7
mm

7/21 S

2S

0.420
in
10.7
mm

7/21 S

BC

0.475
in
12.1
mm

7/21 BC

BC

0.475
in
12.1
mm

7/21 BC

11

50711

Coax
Cable

75

22.0
pF/ft
72.2
pF/m

11A*

50711A

Coax
Cable

75

22.0
pF/ft
72.2
pF/m

12

50712

Coax
Cable

75

20.5
pF/ft
67.3
pF/m

12A*

50712A

Coax
Cable

75

20.5
pF/ft
67.3
pF/m

13

50713

Coax
Cable

74

20.5
pF/ft
67.3
pF/m

13A*

50713A

Coax
Cable

74

20.5
pF/ft
67.3
pF/m

PE

PE

BC

0.405
in
10.3
mm

7/26 TC

BC

0.405
in
10.3
mm

7/26 TC

BC

0.475
in
12.1
mm

7/26 TC

BC

0.475
in
12.1
mm

7/26 TC

PVC-I

2
BC

0.420
in
10.7
mm

7/26 TC

PVC-IIA

2
BC

0.420
in
10.7
mm

7/26 TC

PVC-I

PVC-IIA

PE

PVC-II
w/armor

PE

PVC-IIA
w/armor

PE

PE

14

50714

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

14A*

50714A

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

PE

PE

PVC-II

2
BC

0.545
in
13.8
mm

PVC-IIA

2
BC

0.545
in
13.8
mm

0.1020 BC

2
BC

0.545
in
13.8
mm

0.0571
CW

BC

0.630
in
16.0
mm

0.125 BC
tube

0.188 BC

0.188 BC

15

50715

Coax
Cable

76

20.0
pF/ft
65.6
pF/m

16

50716

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

17

50717

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

PE

PVC-II

BC

0.879
in
22.3
mm

17A*

50717A

Coax
Cable

52

29.5
pF/ft
96.8

PE

PVC-IIA

BC

0.870
in
22.1

PE

PE

PVC-I

PVC-I

0.1020 BC

17B

50717B

Coax
Cable

pF/m

mm

52

29.5
pF/ft
96.8
pF/m

2S

0.940
in
23.9
mm

0.188 BC

BC

0.945
in
24.0
mm

0.188 BC

BC

0.945
in
24.0
mm

0.188 BC

BC

1.120
in
28.4
mm

0.250 BC

1.120
in
28.4
mm

0.250 BC

18

50718

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

18A*

50718A

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

19

50719

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

19A*

50719A

Coax
Cable

52

29.5
pF/ft
96.8
pF/m

20

50720

Coax
Cable

52

29.5
pF/ft

PE

PVC-IIA

PE

PVC-IA
w/armor

PE

PVC-IIA
w/armor

PE

PVC-II

PE

PVC-IIA

BC

PE

PVC-II
w/armor

BC

1.195
in

0.250 BC

96.8
pF/m

20A*

50720A

Coax
Cable

52

29.6
pF/ft
97.1
pF/m

21

50721

Coax
Cable

53

29.0
pF/ft
95.1
pF/m

21A*

50721A

Coax
Cable

53

29.0
pF/ft
95.1
pF/m

22

50722

Coax
Cable

95

18.4
pF/ft
60.4
pF/m

22A

50722A

Coax
Cable

95

16.3
pF/ft
53.5
pF/m

30.4
mm

PE

PE

PE

PE

PE

BC

1.178
in
29.92
mm

0.250 BC

2S

0.332
in
8.43
mm

0.0508 N

PVC-IIA

2S

0.332
in
8.43
mm

0.0508 N

PVC-IIA

2
TC

0.420
in
10.7
mm

2 cond.
7/0.0152
BC

PVC-IIA

2
TC

0.420
in
10.7
mm

2 cond.
7/0.0152
BC

PVC-IIA
w/armor

PVC-II

22B*

23

23A*

50722B

50723

50723A

Coax
Cable

Coax
Cable

Coax
Cable

95

125

125

16.3
pF/ft
53.5
pF/m

13.0
pF/ft
42.7
pF/m

13.0
pF/ft
42.7
pF/m

PE

PE

PE

PVC-IIA

PVC-I

PVC-IIA

2
TC

0.420
in
10.7
mm

2 cond.
7/0.0152
BC

2
BC

0.650
x
0.945
in
16.5 x
24.0
mm

2 cond.
7/21 BC

2
BC

0.650
x
0.945
in
16.5 x
24.0
mm

2 cond.
7/21 BC

2 cond.
7/21 BC

2 cond.

24

50724

Coax
Cable

125

13.0
pF/ft
42.7
pF/m

PE

PVC-I
w/armor

2
BC

0.735
x
1.034
in
18.7 x
26.3
mm

24A*

507-

Coax

125

13.0
pF/ft

PE

PVC-IIA

0.735
x

24A

Cable

25*

50725

Coax
Cable

48

50.0
pF/ft
164
pF/m

25A*

50725A

Coax
Cable

48

50.0
pF/ft
164
pF/m

26*

50726

Coax
Cable

48

50.0
pF/ft
164
pF/m

48

50.0
pF/ft
164
pF/m

26A*

50726A

Coax
Cable

42.7
pF/m

w/armor

BC

1.034
in
18.7 x
26.3
mm

7/21 BC

Rubber

RubberIV

2
TC

0.505
in
12.8
mm

19/0.0117
TC

Rubber

RubberIV

2
TC

0.505
in
12.8
mm

19/0.0117
TC

Rubber

RubberIV
w/armor

TC

0.525
in
13.3
mm

19/0.0117
TC

Rubber

RubberIV
w/armor

TC

0.505
in
12.8
mm

19/0.0117
TC

50727

27

Catal
og
No.

RG/
U
No.

27A*

28

Coax
Cable

Nom.
Imp.

Type

507-27A

507-28

48

Coax
Cable

Coax
Cable

50.0
pF/ft
164
pF/m

Cap
.

Rubber

Dielect
. Mat.

48

50.0
pF/ft
164
pF/m

50

50.0
pF/ft
164
pF/m

PVC-II

Jacket

Rubb
er

Rubb
er

0.675
in
17.1
mm

TC

RubberIV
w/armor

RubberIV

Siz
e
(in)
and
Typ
e of
Inn
er
Co
nd.

Overa
ll
Diam
eter

Shield

19/0.0185
TC

TC

0.6
70
in
17.
0
mm

19/0.0
185
TC

TC
GS

0.8
05
in
20.
4
mm

19/0.0
185
TC

28A

28B*

29

30

507-28A

507-28B

507-29

507-30

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

50

50.0
pF/ft
164
pF/m

48

50.0
pF/ft
164
pF/m

53.5

28.5
pF/ft
93.5
pF/m

50

27.0
pF/ft
88.6
pF/m

Rubb
er

Rubb
er

PE

Copo
.

RubberIV
w/armor

RubberIV

PE-III

PVC-I

TC

0.8
05
in
20.
4
mm

19/0.0
185
TC

TC
GS

0.7
50
ma
x.
in
19.
1
ma
x.
mm

19/0.0
185
TC

TC

0.1
84
in
4.6
7
mm

0.032
0 BC

BC

0.2
50
in
6.3
5

7/26
BC

mm

31

32

33

34

507-31

507-32

507-33

507-34

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

51

31.0
pF/ft
102
pF/m

51

29.0
pF/ft
95.1
pF/m

51

30.0
pF/ft
98.4
pF/m

71

21.5
pF/ft
70.5
pF/m

Copo
.

Copo
.

PE

PE

PVC-I

PVC-I
w/armor

Lead

PVC-I

BC

0.4
05
in
10.
3
mm

7/21
BC

BC

0.4
65
in
11.
8
mm

7/21
BC

Non
e

0.4
70
in
11.
9
mm

0.101
9 BC

BC

0.6
25
in
15.
9
mm

7/21
BC

34A

34B*

35

507-34A

507-34B

507-35

Coax
Cable

Coax
Cable

Coax
Cable

71

75

21.5
pF/ft
70.5
pF/m

21.5
pF/ft
70.5
pF/m

PE

PE

PVC-IIA

PVC-IIA

BC

0.6
30
in
16.
0
mm

7/0.02
49 BC

BC

0.6
30
in
16.
0
mm

7/.024
9 BC

BC

0.9
45
in
24.
0
mm

0.114
4 BC

0.104
5 BC

75

22.0
pF/ft
72.2
pF/m

22.0
pF/ft
72.2
pF/m

PE

PVC-IIA
w/armor

BC

0.9
45
in
24.
0
mm

22.0
pF/ft
72.2

PE

PVC-IIA
w/armor

BC

0.9
45
ma

35A

507-35A

Coax
Cable

75

35B*

507-35B

Coax
Cable

75

PE

PVC-II
w/armor

0.104
5 BC

pF/m

36

37

507-36

507-37

Coax
Cable

Coax
Cable

x.
in
24.
0
ma
x.
mm

BC

1.1
80
in
29.
97
mm

0.162
0 BC

TC

0.2
10
in
5.3
3
mm

0.032
0 TC

0.045
3 TC

0.025
3

69

22.0
pF/ft
72.2
pF/m

52.5

38.0
pF/ft
125
pF/m

Rubb
er-C

PE-III

2
TC

0.3
12
in
7.9
2
mm

Rubb

PE-III

0.3
12

38

507-38

Coax
Cable

52.5

38.0
pF/ft
125
pF/m

39

507-39

Coax

72.5

28.6
pF/ft

PE

Rubb
er-C

PVC-I

PE-III

Cable

40

41

42

43

507-40

507-41

507-42

507-43

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

93.8
pF/m

72.5

28.0
pF/ft
91.9
pF/m

67.5

27.6
pF/ft
90.6
pF/m

78.6

20.0
pF/ft
65.6
pF/m

95

17.6
pF/ft
57.7
pF/m

er-C

Rubb
er-C

Rubb
er-C

PE

Rubb
er-B

TC

RubberIV

RubberIV

PVC-II

PVC-I

in
7.9
2
mm

TCW

2
TC

0.4
20
in
10.
7
mm

0.025
3
TCW

TC

0.4
25
in
10.
8
mm

16/30
TC

2S

0.3
42
in
8.6
9
mm

0.028
5N

BC

0.6
17
in
15.
7

2
cond.
7/21
BC

mm

507-44

Stub
support
ed
coaxial

N/A

N/A

N/A

N/A

N/A

N/A

N/A

507-45

Stub
support
ed
coaxial

N/A

N/A

N/A

N/A

N/A

N/A

N/A

507-46

Stub
support
ed
coaxial

N/A

N/A

N/A

N/A

N/A

N/A

N/A

47

507-47

Stub
support
ed
coaxial

N/A

N/A

N/A

N/A

N/A

N/A

N/A

48

507-48

Waveg
uide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

49

507-49

Waveg
uide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

44

45

46

50

507-50

Waveg
uide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

51

507-51

Waveg
uide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

52

507-52

Waveg
uide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

53

507-53

Waveg
uide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

58

27.0
pF/ft
88.6
pF/m

BC

0.2
75
in
7.0
mm

7/26
BC

58

26.5
pF/ft
86.9
pF/m

TC

0.2
50
in
6.4
mm

7/.015
2 BC

53.5

28.5
pF/ft
93.5
pF/m

2
TC

0.2
00
in
5.1
mm

0.320
BC

54

54A

55

507-54

507-54A

507-55

Coax
Cable

Coax
Cable

Coax
Cable

PE

PE

PE

PVC-I

PE-III

PE-III

55A

55B*

56

57

507-55A

507-55B

507-56

507-57

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

50

28.5
pF/ft
93.5
pF/m

53

28.5
pF/ft
93.5
pF/m

48

50.0
pF/ft
164
pF/m

95

17.0
pF/ft
55.8
pF/m

PE

PE

Rubb
er-C

PE

PVC-IIA

PE-III

PVC-I

PVC-I

2S

0.2
00
in
5.1
mm

0.035
S

2
TC

0.2
00
ma
x.
in
5.0
8
ma
x.
mm

0.032
S

2
BC

0.5
35
in
13.
6
mm

19/.01
17 BC

TC

0.6
25
in
15.
9
mm

2
cond.
7/21
BC

57A*

58

58A

58B

58C*

507-57A

507-58

507-58A

Coax
Cable

Coax
Cable

Coax
Cable

507-58B

Coax
Cable

507-

Coax

95

17.0
pF/ft
55.8
pF/m

53.5

28.5
pF/ft
93.5
pF/m

50

32.2
pF/ft
106
pF/m

53.5

28.5
pF/ft
93.5
pF/m

50

32.2
pF/ft

PE

PE

PE

PVC-IIA

PVC-I

PVC-I

TC

0.6
25
in
15.
9
mm

2
cond.
7/21
BC

TC

0.1
95
in
4.9
5
mm

0.032
0 BC

TC

0.1
95
in
4.9
5
mm

19/33
TC

0.1
95
in
4.9
5
mm

0.032
0 BC

0.1
95

19/33

PE

PVC-IIA

TC

PE

PVC-IIA

TC

58C

59

59A

59B*

60

507-59

507-59A

507-59B

507-60

Cable

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

106
pF/m

73

22.0
pF/ft
72.2
pF/m

75

22.0
pF/ft
72.2
pF/m

75

22.0
pF/ft
72.2
pF/m

50

39.0
pF/ft
128
pF/m

in
4.9
5
mm

PE

PE

PE

Rubb
er

PVC-II

PVC-IIA

PVC-IIA

RubberIV

TC

BC

0.2
42
in
6.1
5
mm

0.022
6 CW

BC

0.2
42
in
6.1
5
mm

0.022
6 CW

BC

0.2
42
in
6.1
5
mm

0.022
6 CW

BC

0.4
25
in
10.
8

0.050
8
strand
ed BC

mm

61

507-61

Catal
og
No.

RG
/U
No.

62

62
A*

Special
500
ohm
line

No
m.
Im
p.

Ty
pe

50762

50762A

Coax
Cable

Coax
Cable

N/A

Diele
ct.
Mat.

Ca
p.

N/A

Jac
ket

93

14.
5
pF/
ft
47.
6
pF/
m

Air
spac
e PE

93

14.
5
pF/
ft
47.
6

Air
spac
e PE

N/A

PVCIIA

Size
(in)
and
Typ
e of
Inne
r
Con
d.

Overa
ll
Diam
eter

Shie
ld

PVCIIA

N/A

BC

0.2
42
in
6.1
5
mm

0.0253
CW

BC

0.2
42
in
6.1
5

0.0253
CW

N/A

N/A

N/A

pF/
m

62
B

63

63
A

50762B

50763

50763A

Coax
Cable

Coax
Cable

Coax
Cable

93

14.
5
pF/
ft
47.
6
pF/
m

12
5

11.
0
pF/
ft
36.
1
pF/
m

12
5

11.
0
pF/
ft
36.
1
pF/
m

mm

Air
spac
e PE

Air
spac
e PE

Air
spac
e PE

PVCIIA

PVCIIA

PVCIIA

BC

0.2
42
in
6.1
5
mm

7/32
CW

BC

0.4
05
in
10.
3
mm

0.0253
CW

BC

0.4
05
in
10.
3
mm

0.0253
BC

63
B*

64*

64
A*

65

50763B

50764

50764A

50765

12
5

11.
0
pF/
ft
36.
1
pF/
m

48

50.
0
pF/
ft
16
4
pF/
m

Coax
Cable

48

50.
0
pF/
ft
16
4
pF/
m

Coax
Cable

95
0

Coax
Cable

Coax
Cable

44.
0
pF/
ft
14

Air
spac
e PE

Rubb
er-IV

Rubb
er-IV

PE

PVCIIA

Rubb
er-IV

Rubb
er-IV

PVCI

BC

0.4
05
in
10.
3
mm

0.0253
CW

2
TC

0.4
95
in
12.
6
mm

19/0.0
117
TC

2
TC

0.4
75
in
12.
1
mm

19/0.0
117
TC

BC

0.4
05
in
10.
3

0.0080
Forme
xF

4
pF/
m

mm

65
A*

50765A

Coax
Cable

95
0

44.
0
pF/
ft
14
4
pF/
m

66

50766

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

67

50767

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

68

50768

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

69

50769

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

70

50770

Not
assigne
d

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

PE

PVCIIA

BC

0.4
05
in
10.
3
mm

0.0080
Forme
xF

71

71
A

71
B*

50771

50771A

50771B

Coax
Cable

Coax
Cable

Coax
Cable

93

13.
5
pF/
ft
44.
3
pF/
m

93

13.
5
pF/
ft
44.
3
pF/
m

93

14.
5
ma
x.
pF/
ft
47.
6
ma
x.
pF/
m

Air
spac
e PE

Air
spac
e PE

Air
spac
e PE

PVCI

PE-III

PEIIIA

2
TC

0.2
45
in
6.2
2
mm

0.0253
CW

2
TC

0.2
45
in
6.2
2
mm

0.0253
CW

2
TC

0.2
50
ma
x.
in
6.3
5
ma
x.
mm

0.0253
CW

72

73

74

74
A*

50772

50773

50774

50774A

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

15
0

7.8
pF/
ft
26
pF/
m

25

61.
8
pF/
ft
20
3
pF/
m

52

29.
6
pF/
ft
97.
1
pF/
m

52

29.
6
pF/
ft
97.
1
pF/

Air
spac
e PE

PE

PE

PE

PVCI

None

PVCII
w/ar
mor

PVCIIA
w/ar
mor

BC

0.6
30
in
16.
0
mm

0.0253
CW

2
BC

0.1
75
in
4.4
5
mm

0.0320
BC

2
BC

0.6
03
in
15.
3
mm

0.1020
BC

2
BC

0.6
03
in
15.
3
mm

0.1020
BC

75

50775

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

76

50776

Stub
support
ed
coaxial

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

48

50.
0
pF/
ft
16
4
pF/
m

2
TC

0.4
50
in
11.
4
mm

19/0.0
117
TC

Rubb
er

PVCIIA

TC

0.4
20
in
10.
7
mm

19/0.0
117
TC

Air
spac

PVCI

BC

0.4
75

0.0253

77
A

50777A

Coax
Cable

78
A

50778A

Coax
Cable

48

50.
0
pF/
ft
16
4
pF/
m

79

507-

Coax

12
5

11.
0

Rubb
er

PVCIIA

79

79
A

79
B*

50779A

50779B

Cable

Coax
Cable

Coax
Cable

pF/
ft
36.
1
pF/
m

12
5

11.
0
ma
x.
pF/
ft
36.
1
ma
x.
pF/
m

12
5

11.
0
ma
x.
pF/
ft
36.
1
ma
x.
pF/
m

e PE

w/ar
mor

Air
spac
e PE

PVCI
w/ar
mor

Air
spac
e PE

PVCIIA
w/ar
mor

in
12.
1
mm

CW

BC

0.4
75
in
12.
1
mm

0.0253
CW

BC

0.4
75
in
12.
1
mm

0.0253
CW

80

81*

82*

83

50780

50781

50782

50783

Bead
support
ed
coaxial

Coax
Cable

Coax
Cable

Coax
Cable

N/
A

N/
A

50

37.
0
pF/
ft
12
1
pF/
m

50

36.
0
pF/
ft
11
8
pF/
m

35

44.
0
pF/
ft
14
4
pF/

N/A

Mag.
Ox.

Mag.
Ox.

PE

N/A

None

None

PVCI

N/A

N/A

N/A

BC
Tub
e

0.3
25
in
8.2
6
mm

0.0625
BC

BC
Tub
e

0.7
50
in
19.
1
mm

0.1250
BC

BC

0.4
05
in
10.
3
mm

0.1020
BC

84
A*

85
A*

86*

50784A

50785A

50786

Coax
Cable

Coax
Cable

Coax
Cable

75

21.
5
pF/
ft
70.
5
pF/
m

75

21.
5
pF/
ft
70.
5
pF/
m

20
0

7.8
pF/
ft
26
pF/
m

PE

PVCIIA
w/lea
d

PE

PVCIIA
w/lea
d

PE

None

BC

1.0
00
in
25.
40
mm

0.1045
BC

BC

1.5
65
in
39.
75
mm

0.1045
BC

Non
e

0.6
50
x
0.3
00
in
16.
5x
7.6
2
mm

2
cond.
7/21
BC

87

87
A*

50787

50787A

Coax
Cable

Coax
Cable

50

29.
5
pF/
ft
96.
8
pF/
m

50

29.
5
pF/
ft
96.
8
pF/
m

Rubb
er

PVCI

4
TC

0.5
15
ma
x.
in
13.
1
ma
x.
mm

Rubb

PVC-

0.5
15

88*

50788

Coax
Cable

48

50.
0
pF/
ft
16
4
pF/
m

88

507-

Coax

48

50.
0

TFE

TFE

FG-V

FG-V

BC
&S

0.4
25
in
10.
8
mm

7/20 S

2S

0.4
25
in
10.
8
mm

7/20 S

19/0.0
117
TC

19/0.0
117

A*

88
B

89

90

88A

50788B

50789

50790

Cable

Coax
Cable

Coax
Cable

Coax
Cable

pF/
ft
16
4
pF/
m

48

50.
0
pF/
ft
16
4
pF/
m

12
5

10.
0
pF/
ft
32.
8
pF/
m

50

30.
8
pF/
ft
10

er

Rubb
er

Air
spac
e PE

PE

IIA

TC

ma
x.
in
13.
1
ma
x.
mm

TC

4
TC

0.5
65
in
14.
4
mm

19/0.0
117
TC

PVCI

BC

0.6
32
in
16.
1
mm

0.0253
CW

PVCIIA

2
TC
1
GS

0.4
25
in
10.
8

7/24 S

Rubb
er-IV

1
pF/
m

mm

91

50791

Waveg
uide

N/
A

N/
A

N/A

92

50792

Coax
Cable

46

N/
A

SS
TFE

50

29.
0
pF/
ft
95.
1
pF/
m

50

29.
0
pF/
ft
95.
1
pF/
m

93

94*

50793

50794

Coax
Cable

Coax
Cable

TFE
tape

TFE
tape

N/A

N/A

N/A

N/A

None

BC
Tub
e

N/A

0.375
BC

BC

0.7
10
in
18.
0
mm

19/18
BC

2
BC

0.4
45
in
11.
3
mm

19/23
S

FG-V

FG-V

94
A

50794A

Coax
Cable

50

29.
0
pF/
ft
95.
1
pF/
m

95

50795

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

96

50796

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

Catal
og
No.

RG/
U
No.

97

FG-V

Nom.
Imp.

Type

507-97

TFE
tape

Wavegu
ide

Ca
p.

N/
A

2
BC

0.5
00
in
12.
7
mm

19/22
S

Dielec
t. Mat.

N/A

N/A

Overa
ll
Diam
eter

Shiel
d

Jacket

N/A

Siz
e
(in)
and
Typ
e of
Inn
er
Con
d.

N/A

N/A

N/A

98

507-98

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

99

507-99

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

35

44.0
pF/ft
144
pF/m

BC

0.2
42
in
6.1
5
mm

19/0.0
147
BC

TC

0.5
88
in
14.
9
mm

0.0641
BC

TC

1.0
88
in
27.
64
mm

2
cond.
0.0808
BC

100

101

102

507-100

507-101

507-102

Coax
Cable

Coax
Cable

Coax
Cable

75

14
0

N/A

N/A

PE

Rubbe
r

Rubbe
r

PVC-I

103

507-103

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

104

507-104

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

105

507-105

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

106

507-106

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

107

507-107

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

78

24.5
pF/ft
80.4
pF/m

TC

0.2
35
in
5.9
7
mm

2
cond.
7/28
TC

108

507-108

Coax
Cable

PE

XL
polyolefi
n

PE

XL
polyolefi
n

TC

0.2
35
in
5.9
7
mm

108A*

507108A

Coax
Cable

78

24.5
pF/ft
80.4
pF/m

109

507-109

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

110

507-110

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

2
TC

0.4
90
in
12.
4
mm

2
cond.
7/0.01
52 BC

2
TC

0.4
90
in
12.
4
mm

2
cond.
7/0.01
52 BC

111

111A*

507-111

507111A

Coax
Cable

Coax
Cable

95

95

18.4
pF/ft
60.4
pF/m

18.4
pF/ft
60.4
pF/m

PE

PE

PVC-II
w/armor

PVC-IIA
w/armor

2
cond.
7/28
TC

112

507-112

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

113

507-113

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

18
5

6.8
pF/ft
22
pF/m

BC

0.4
05
in
10.
3
mm

0.0070
CW

BC

0.4
05
in
10.
3
mm

0.0070
CW

2S

0.4
15
in
10.
5

7/21 S

114

114A*

115*

507-114

507114A

507-115

Coax
Cable

Coax
Cable

Coax
Cable

18
5

6.8
pF/ft
22
pF/m

50

32.0
pF/ft
105
pF/m

Air
space
PE

Air
space
PE

TFE
tape

PVC-IIA

PVC-IIA

FG-V

mm

115A*

116*

117*

117A*

507115A

507-116

507-117

507117A

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

50

50

32.0
pF/ft
105
pF/m

29.5
pF/ft
96.8
pF/m

50

29.5
pF/ft
96.8
pF/m

50

29.5
pF/ft
96.8
pF/m

TFE
tape

TFE

TFE

TFE

FG-V

FG-V
w/armor

FG-V

FG-V

2S

0.4
15
in
10.
5
mm

7/21 S

2S

0.4
75
in
12.
1
mm

7/20 S

BC

0.7
30
in
18.
5
mm

0.188
BC

BC

0.7
30
in
18.
5

0.188
BC

mm

118*

118A*

119*

120*

507-118

507118A

507-119

507-120

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

50

50

29.0
pF/ft
95.1
pF/m

29.0
pF/ft
95.1
pF/m

50

29.3
pF/ft
96.1
pF/m

50

29.3
pF/ft
96.1
pF/m

TFE

TFE

TFE

TFE

FG-V
w/armor

FG-V
w/armor

FG-V

FG-V
w/armor

BC

0.7
80
in
19.
8
mm

0.188
BC

BC

0.7
80
in
19.
8
mm

0.188
BC

2
BC

0.4
65
in
11.
8
mm

0.102
BC

2
BC

0.5
23
in
13.
3

0.102
BC

mm

121

507-121

Wavegu
ide

122*

507-122

Coax
Cable

123

507-123

Not
assigne
d

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

27/36
TC

50

30.8
pF/ft
101
pF/m

PE

PVC-IIA

TC

0.1
60
in
4.0
6
mm

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

TFE
tape

FG-V

TC

0.2
40
in
6.1
0
mm

0.0253
TCW

Air
space

PVC-IIA

BC

0.6
00
in

124

507-124

Coax
Cable

73

20.3
pF/ft
66.6
pF/m

125

507-125

Coax
Cable

15
0

7.8
pF/ft
26

0.0159
CW

126*

507-126

Coax
Cable

pF/m

50

29.0
pF/ft
95.1
pF/m

PE

TFE

15.
2
mm

FG-V

HR

0.2
80
in
7.1
1
mm

7/24
HR

0.644
BC

128

507-128

Coax
Cable

50

N/A

SS
TFE

None

BC
Tub
e

1.6
25
in
41.
28
mm

129

507-129

Flexible
Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

95

17.0
pF/ft
55.8
pF/m

TC

0.6
25
in
15.
9

2
cond.
7/21
BC

130*

507-130

Coax
Cable

PE

PVC-I

mm

131*

507-131

Coax
Cable

132

507-132

Wavegu
ide

133

133A*

507-133

507133A

Coax
Cable

Coax
Cable

95

17.0
pF/ft
55.8
pF/m

N/
A

N/A

95

16.2
pF/ft
53.1
pF/m

95

16.2
pF/ft
53.1
pF/m

PE

PVC-I
w/armor

TC

0.7
10
in
18.
0
mm

N/A

N/A

N/A

N/A

N/A

BC

0.4
05
in
10.
3
mm

0.0285
BC

BC

0.4
05
in
10.
3
mm

0.0253
BC

PE

PE

PVC-I

PVC-IIA

2
cond.
7/21
BC

Bras
s

0.4
50
in
11.
4
mm

0.0126
BC

134

507-134

Coax
Cable

18
5

6.5
pF/ft
21
pF/m

135

507-135

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

136

507-136

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

137

507-137

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

138

507-138

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

139

507-139

Wavegu
ide

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

140*

507-140

Coax

75

21.0
pF/ft

TFE

FG-V

0.2
33

0.0250

SS
TFE

None

Cable

Catal
og
No.

RG
/U
No.

141

141
A*

No
m.
Imp
.

Ty
pe

507141

507141
A

Coax
Cable

Coax
Cable

68.9
pF/m

Diele
ct.
Mat.

Ca
p.

50

29.
4
pF/
ft
96.
5
pF/
m

50

29.
4
pF/
ft
96.
5

in
5.9
2
mm

Jack
et

TFE

TFE

Overa
ll
Diame
ter

Shie
ld

FG-V

FG-V

Siz
e
(in)
and
Typ
e of
Inn
er
Con
d.

0.1
90
in
4.8
3
mm

0.03
59
SCC
S

0.1
90
in
4.8
3
mm

0.03
90
SCC
S

SCCS

pF/
m

142

142
A*

142
B*

507142

507142
A

507142
B

Coax
Cable

Coax
Cable

Coax
Cable

50

29.
3
pF/
ft
96.
1
pF/
m

50

29.
3
pF/
ft
96.
1
pF/
m

50

29.
3
pF/
ft
96.
1
pF/
m

TFE

TFE

TFE

FEPIX

FEPIX

FEPIX

2S

0.1
95
in
4.9
5
mm

0.03
70
SCC
S

2S

0.1
95
in
4.9
5
mm

0.03
70
SCC
S

2S

0.1
95
in
4.9
5
mm

0.03
70
SCC
S

143

143
A*

144
*

507143

507143
A

507144

Coax
Cable

Coax
Cable

Coax
Cable

50

29.
4
pF/
ft
96.
5
pF/
m

50

29.
4
pF/
ft
96.
5
pF/
m

75

22.
0
pF/
ft
72.
2
pF/
m

TFE

TFE

TFE

FG-V

FG-V

FG-V

2S

0.3
25
in
8.2
6
mm

0.05
70
SCC
S

2S

0.3
25
in
8.2
6
mm

0.05
90
SCC
S

0.4
10
in
10.
4
mm

7/25
SCC
S

145

146

507145

507146

Coax
Cable

Coax
Cable

75

14.
6
pF/
ft
47.
9
pF/
m

19
0

6.0
pF/
ft
20
pF/
m

29.
5
pF/
ft
96.
8
pF/
m

147

507147

Coax
Cable

52

148

507148

Coax
Cable

52

29.
5
pF/
ft

Air
space
PE

Lead
-tar

Air
space
TFE

FG-V

PE

PVCI
w/ar
mor

PE

PVCI
w/ar
mor

BC
Tube

N/A

2
con
d.
0.07
20
BC

BC

0.3
75
in
9.5
3
mm

0.00
70
CW

BC

1.9
38
in
49.
23
mm

0.25
0
BC

BC

0.8
00
in
20.

7/21
BC

96.
8
pF/
m

149
*

150
*

151
*

507149

507150

507151

Coax
Cable

Coax
Cable

Coax
Cable

75

20.
5
pF/
ft
67.
3
pF/
m

75

20.
5
pF/
ft
67.
3
pF/
m

50

N/
A

3
mm

PE

PE

N/A

PVCIIA

PVCIIA
w/ar
mor

None

BC

0.4
05
in
10.
3
mm

7/26
TC

BC

0.4
75
in
12.
1
mm

7/26
TC

BC
Tube

0.3
75
in
9.5
3
mm

0.12
5
BC
tube

152
*

153
*

154

155

507152

507153

507154

507155

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

50

50

50

50

N/
A

N/
A

N/
A

N/
A

N/A

N/A

N/A

N/A

None

None

None

None

BC
Tube

6.1
25
in
156
mm

2.60
BC
tube

BC
Tube

1.6
25
in
41.
28
mm

0.66
4
BC
tube

BC
Tube

3.1
25
in
79.
38
mm

1.31
5
BC
tube

BC
Tube

0.8
75
in
22.
2
mm

0.34
1
BC
tube

156
*

157
*

158
*

507156

507157

507158

Coax
Cable

Coax
Cable

Coax
Cable

50

32.
8
pF/
ft
10
8
pF/
m

50

38.
0
pF/
ft
12
5
pF/
m

25

78.
0
pF/
ft
25
6
pF/
m

PE &
conduc
tive PE

PE &
conduc
tive PE

PE &
conduc
tive PE

PVCIIA

PVCIIA

PVCIIA

TC,
GS,
TC

0.5
40
in
13.
7
mm

7/21
TC

TC,
GS,
TC

0.7
25
in
18.
4
mm

19/2
4
TC

TC,
GS,
TC

0.7
25
in
18.
4
mm

37/2
1
TC

159

160

160
A

507159

507160

507160
A

Coax
Cable

Coax
Cable

Coax
Cable

50

29.
0
pF/
ft
95.
1
pF/
m

12
5

12.
0
pF/
ft
39.
4
pF/
m

12
5

12.
0
pF/
ft
39.
4
pF/
m

TFE
tape

PE

PE

FG-V

PVCI

PVCI

BC

BC

0.1
95
in
5.0
mm

0.03
20 S

1.0
55
in
26.
80
mm

2
con
d.
19/2
7
TC
2
con
d.
19/2
7
BC

1.0
55
in
26.
80
mm

2
con
d.
19/2
7
TC
2
con
d.

19/2
7
BC

161

507161

Coax
Cable

70

20.
9
pF/
ft
68.
6
pF/
m

TFE

nylon

0.0
82
in
2.1
mm

7/38
SCB

3.0
65
in
77.
85
mm

0.15
6
BC
tube

162

507162

Coax
Cable

17
5

N/
A

SS
TFE

None

BC
Tube

163

507163

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

75

22.
0
pF/
ft
72.

BC

0.8
70
in
22.
1

0.10
45
BC

164
*

507164

Coax
Cable

PE

PVCIIA

2
pF/
m

165
*

507165

Coax
Cable

mm

50

29.
3
pF/
ft
96.
1
pF/
m

TFE

FG-V
w/ar
mor

0.4
70
in
11.
9
mm

TFE

FG-V

0.4
10
in
10.
4
mm

7/20
S

7/20
S

166
*

507166

Coax
Cable

50

29.
3
pF/
ft
96.
1
pF/
m

167

507167

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

168

507168

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

169

507169

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

170

507170

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

171

507171

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

172

507172

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

173

507173

Waveg
uide

N/
A

N/
A

N/A

N/A

N/A

N/A

N/A

50

32.
2
pF/
ft
10
6
pF/
m

TC

0.1
10
in
2.7
9
mm

7/34
CW

174
*

507174

Coax
Cable

PE

PVCIIA

174
A*

175

507174
A

Coax
Cable

50

30.
8
pF/
ft
10
1
pF/
m

507175

Bead
support
ed
coaxial
line

N/
A

N/
A

49.
0
pF/
ft
16
1
pF/
m

176
*

507176

Coax
Cable

22
40

177
*

507177

Coax
Cable

50

32.
2
pF/
ft

PE

PVCIIA

N/A

N/A

PE

PVCI

PE

PVCIIA

TC

0.1
00
in
2.5
4
mm

7/34
CW

N/A

N/A

N/A

BC

0.4
05
in
10.
3
mm

0.13
5
BC
helix

2S

0.8
95
in
22.

0.19
5
BC

10
6
pF/
m

178

507178

Coax
Cable

7
mm

0.0
79
ma
x.
in
2.0
1
ma
x.
mm

7/38
SC
W

7/38
SC
W

7/38
SC

50

32.
0
pF/
ft
10
5
pF/
m

TFE

FEPIX

0.0
75
ma
x.
in
1.9
1
ma
x.
mm

TFE

FEPIX

0.0
75

178
A*

507178
A

Coax
Cable

50

32.
0
pF/
ft
10
5
pF/
m

178
B*

507178

Coax
Cable

50

32.
0

TFE

FEPIX

179

179
A*

507179

507179
A

pF/
ft
10
5
pF/
m

Coax
Cable

Coax
Cable

75

23.
0
pF/
ft
75.
5
pF/
m

75

23.
0
pF/
ft
75.
5
pF/
m

ma
x.
in
1.9
1
ma
x.
mm

TFE

TFE

FEPIX

FEPIX

0.1
00
ma
x.
in
2.5
4
ma
x.
mm

7/38
SCC
S

0.1
05
ma
x.
in
2.6
7
ma
x.
mm

7/38
SCC
S

179
B*

180

507179
B

507180

Coax
Cable

Coax
Cable

75

95

23.
0
pF/
ft
75.
5
pF/
m

15.
4
pF/
ft
50.
5
pF/
m

TFE

TFE

FEPIX

FEPIX

0.1
05
ma
x.
in
2.6
7
ma
x.
mm

7/38
SCC
S

0.1
41
ma
x.
in
3.5
8
ma
x.
mm

7/38
SCC
S

Catal
og
No.

RG/
U
No.

180A*

180B*

Nom.
Imp.

Type

507180A

507180B

Coax
Cable

Coax
Cable

Ca
p.

95

95

Dielect
. Mat.

15.4
pF/ft
50.5
pF/m

15.4
pF/ft
50.5
pF/m

Jacket

TFE

TFE

Overa
ll
Diam
eter

Shield

FEP-IX

FEP-IX

Siz
e
(in)
and
Typ
e of
Inn
er
Co
nd.

0.1
45
ma
x.
in
3.6
8
ma
x.
mm

0.1
45
ma
x.
in
3.6
8
ma
x.

7/38
SCCS

7/38
SCCS

mm

181*

182

183

184

507181

507182

Coax
Cable

Coax
Cable

507183

Coax
Cable

507-

Waveg

125

125
each

12.0
pF/ft
39.4
pF/m

12.0
each
pF/ft
39.4
each
pF/m

PE

PE

PVC-IIA

PVC-IIA

0.6
40
in
16.
3
mm

2
cond.
7/26
BC

2 BC

1.0
55
in
26.
8
mm

2
cond.
19/0.0
142
BC 2
cond.
19/0.0
066
TC

0.0251
BC

N/A

BC

50

23.0
pF/ft
75.5
pF/m

PS
helix

None

AL
Tube

0.7
50
in
19.
1
mm

N/A

N/A

N/A

N/A

N/A

N/A

184

185

186

187

507185

507186

507187

uide

Coax
Cable

Coax
Cable

Coax
Cable

2000

1000

75

N/A

N/A

19.5
pF/ft
64.0
pF/m

Air
spac
e PE

SS
PE

TFE

PVC-IIA

PVC-IIA

TFE

Magn
et
wire

0.2
82
in
7.1
6
mm

0.0031
RIM
helix

Magn
et
wire

0.4
05
in
10.
3
mm

0.0080
TFE
Magne
t wire
helix

0.1
10
ma
x.
in
2.7
9
ma
x.
mm

7/38
SCCS

187A*

188*

188A*

507187A

507188

507188A

Coax
Cable

Coax
Cable

Coax
Cable

75

50

50

19.5
pF/ft
64.0
pF/m

29.0
pF/ft
95.1
pF/m

29.0
pF/ft
95.1
pF/m

TFE

TFE

TFE

TFE

TFE

TFE

0.1
10
ma
x.
in
2.7
9
ma
x.
mm

7/38
SCCS

0.1
10
ma
x.
in
2.7
9
ma
x.
mm

7/0.00
67
SCCS

0.1
10
ma
x.
in
2.7
9
ma
x.

7/0.00
67
SCCS

mm

189

190*

191*

192

507189

507190

507191

507192

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

50

50

23.0
pF/ft
75.5
pF/m

50.0
pF/ft
164
pF/m

PS
helix

Rubb
er

25

85.0
pF/ft
279
pF/m

Rubb
er

12.5

175.0
pF/ft
574.1
pF/m

Butyl
rubb
er

2S

0.8
75
in
22.
2
mm

0.251
BC

TC,
GS,
TC

0.7
00
in
17.
8
mm

19/0.0
117
TC

Neoprene
VIII

TC,
GS,
TC

1.4
60
in
37.
1
mm

TC
braid
0.485

Rubber

TC,
GS,
GS

2.1
65
in
55.
0

PE-IIIA

Neoprene
VIII

TC
braid
GS
tube

mm

193

194

195*

507193

507194

507195

Coax
Cable

Coax
Cable

Coax
Cable

12.5

12.5

95

159.0
pF/ft
521.7
pF/m

159.0
pF/ft
521.7
pF/m

15.0
pF/ft
49.2
pF/m

Silico
ne
rubb
er

Silico
ne
rubb
er

TFE

Rubber

Rubber
w/AL
armour

TFE

TC,
GS,
GS

2.1
65
in
55.
0
mm

TC
braid
GW
tube

TC,
GS,
GS

2.0
1
ma
x.
in
51.
1
ma
x.
mm

TC
braid
GW
tube

0.1
55
ma
x.
in
3.9
4
ma
x.

7/38
SCCS

mm

195A*

196*

196A*

507195A

507196

507196A

Coax
Cable

Coax
Cable

Coax
Cable

95

15.0
pF/ft
49.2
pF/m

50

28.5
pF/ft
93.5
pF/m

50

28.5
pF/ft
93.5
pF/m

TFE

TFE

TFE

TFE

TFE

TFE

0.1
55
ma
x.
in
3.9
4
ma
x.
mm

7/38
SCCS

0.0
80
ma
x.
in
2.0
3
ma
x.
mm

7/38
SCCS

0.0
80
ma
x.
in

7/38
SCCS

2.0
3
ma
x.
mm

197

198

199

507197

507198

507199

Coax
Cable

Coax
Cable

Coax
Cable

50

22.0
pF/ft
72.2
pF/m

70

16.0
pF/ft
52.5
pF/m

70

16.0
pF/ft
52.5
pF/m

PS
helix

PS
helix

PS
helix

None

PE

PE

AL
Tube

0.8
75
in
22.
2
mm

0.300
BC

AL
Tube

0.6
00
in
15.
2
mm

0.114
BC

AL
Tube

1.0
15
in
25.
8
mm

0.209
BC

AL
Tube

1.7
65
in
44.
8
mm

0.403
BC

200

507200

Coax
Cable

70

16.0
pF/ft
52.5
pF/m

201

507201

Rigid
wavegu
ide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

202

507202

Rigid
wavegu
ide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

203

507203

Rigid
wavegu
ide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

204

507204

Rigid
wavegu
ide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

205

507205

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Rigid
wavegu

PS
helix

PE

ide

206

507206

Rigid
wavegu
ide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

207

507207

Rigid
wavegu
ide

N/A

N/A

N/A

N/A

N/A

N/A

N/A

208

507208

Rigid
wavegu
ide

N/A

N/A

N/A

N/A

N/A

N/A

19/0.0
38 S

2S

0.7
50
ma
x.
in
19.
1
ma
x.
mm

19/0.0
378
SC

209*

507209

Coax
Cable

50

26.5
pF/ft
86.9
pF/m

Air
spac
e
TFE

Silicone
rubber &
FG

210*

211*

211A*

212*

507210

507211

507211A

507212

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

93

14.5
pF/ft
47.6
pF/m

50

29.3
pF/ft
96.1
pF/m

50

29.4
pF/ft
96.5
pF/m

50

30.8
pF/ft
101
pF/m

Air
spac
e
TFE

TFE

TFE

PE

FG-V

FG-V

FG-V

PVC-IIA

0.2
42
in
6.1
5
mm

0.0253
BC

BC

0.7
30
in
18.
5
mm

0.190
BC

BC

0.7
30
in
18.
5
mm

0.190
BC

2S

0.3
32
in
8.4
mm

0.0556
SC

213*

214*

215*

216*

507213

507214

507215

507216

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

50

30.8
pF/ft
101
pF/m

50

32.2
pF/ft
106
pF/m

50

30.8
pF/ft
101
pF/m

75

22.0
pF/ft
72.2
pF/m

PE

PE

PE

PE

PVC-IIA

PVC-IIA

PVC-IIA w/
armor

PVC-IIA

BC

0.4
05
in
10.
3
mm

7/0.02
96 BC

2S

0.4
25
in
10.
8
mm

7/0.02
96 SC

BC

0.4
75
in
12.
1
mm

7/0.02
96 BC

2 BC

0.4
25
in
10.
8
mm

7/26
TC

217*

218*

507217

507218

Coax
Cable

Coax
Cable

219*

507219

Coax
Cable

220*

507220

Coax
Cable

50

32.2
pF/ft
106
pF/m

50

32.2
pF/ft
106
pF/m

50

32.2
pF/ft
106
pF/m

50

30.8
pF/ft
101
pF/m

PE

PE

PE

PE

PVC-IIA

PVC-IIA

PVC-IIA w/
armor

PVC-IIA

2 BC

0.5
45
in
13.
8
mm

0.106
BC

BC

0.8
70
in
22.
1
mm

0.195
BC

BC

0.9
45
ma
x.
in
24.
0
ma
x.
mm

0.195
BC

BC

1.1
20
in
28.

0.260
BC

4
mm

221*

222*

223*

507221

507222

507223

Coax
Cable

Coax
Cable

Coax
Cable

50

30.8
pF/ft
101
pF/m

50

30.8
pF/ft
101
pF/m

50

30.8
pF/ft
101
pF/m

PE

PE

PE

PVC-IIA w/
armor

PVC-IIA

PVC-IIA

BC

1.1
95
in
30.
4
mm

0.260
BC

2S

0.3
32
in
8.4
mm

0.0556
resista
nce

2S

0.2
12
in
5.4
mm

0.035
S

Catal
og
No.

RG
/U
No.

224
*

225
*

No
m.
Im
p.

Ty
pe

507224

507225

Coa
x
Cab
le

Coa
x
Cab
le

Diele
ct.
Mat.

Ca
p.

50

30.
8
pF/f
t
101
pF/
m

50

29.
4
pF/f
t
96.
5
pF/
m

Jac
ket

PE

TFE

Overa
ll
Diam
eter

Shi
eld

PVCIIA w/
armo
r

FG-V

Size
(in)
and
Type
of
Inner
Cond.

2
BC

0.6
15
ma
x.
in
15.
6
ma
x.
mm

0.106
BC

2S

0.4
30
in
10.
9
mm

7/0.03
12 S

226
*

227
*

228
*

507226

507227

507228

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

50

29.
4
pF/f
t
96.
5
pF/
m

50

29.
4
pF/f
t
96.
5
pF/
m

50

29.
4
pF/f
t
96.
5
pF/
m

Tape
d
TFE

TFE

TFE

FG-V

FG-V
w/
armo
r

FG-V
w/
armo
r

2
BC

0.5
00
in
12.
7
mm

19/0.0
254 S

2S

0.4
90
ma
x.
in
12.
4
ma
x.
mm

7/0.03
12 S

BC

0.7
95
ma
x.
in
20.
2
ma
x.
mm

0.190
BC

228
A*

229

230
*

507228
A

507229

507230

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

50

29.
4
pF/f
t
96.
5
pF/
m

50

29.
4
pF/f
t
96.
5
pF/
m

25

100
.0
pF/f
t
328
.1
pF/
m

TFE

TFE

Rub
ber

FG-V
w/
armo
r

FG-V

Rubb
er-IV

BC

0.7
95
ma
x.
in
20.
2
ma
x.
mm

0.190
BC

0.4
60
in
11.
7
mm

7/20 S

TC,
GS,
GS

0.7
40
in
18.
8
mm

37/21
TC

231

231
A

232

507231

507231
A

507232

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

50

25.
0
pF/f
t
82.
0
pF/
m

50

25.
0
pF/f
t
82.
0
pF/
m

50

22.
0
pF/f
t
72.
2
pF/
m

PE
foam

PE
foam

PE
helix

None

None

PEIIIA

Al
tube

0.5
00
in
12.
7
mm

0.162
BC
tube

Al
tube

0.5
00
in
12.
7
mm

0.162
BC

Al
tube

1.0
15
in
25.
78
mm

0.300
BC

233

234

235
*

507233

507234

507235

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

50

22.
0
pF/f
t
72.
2
pF/
m

50

22.
0
pF/f
t
72.
2
pF/
m

50

29.
5
pF/f
t
96.
8
pF/
m

PS
helix

PS
helix

TFE
tape

PEIIIA

PEIIIA

Silico
ne
rubb
er

Al
tube

1.7
65
in
44.
83
mm

BC
tube

Al
tube

3.2
95
in
83.
69
mm

BC
tube

2S

0.4
70
ma
x.
in
11.
9
ma
x.
mm

7/21 S

236

507236

Coa
x
Cab
le

50

24.
0
pF/f
t
78.
7
pF/
m

50

24.
0
pF/f
t
78.
7
pF/
m

PS
helix

PEIIIA

Al
tube

0.6
00
in
15.
2
mm

PS
helix

None

Al
tube

0.5
00
in
12.
7
mm

0.162
BC

0.162
BC

237

507237

Coa
x
Cab
le

238

507238

Coa
x
Cab
le

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

507239

Coa
x
Cab
le

N/
A

N/A

N/A

N/A

N/A

N/A

N/A

239

240

507240

Coa
x
Cab
le

50

22.
0
pF/f
t
72.
2
pF/
m

241

507241

Coa
x
Cab
le

N/
A

N/A

PS
helix

None

Al
tube

3.1
25
in
79.
38
mm

N/A

N/A

N/A

N/A

242

243

507242

Coa
x
Cab
le

50

22.
0
pF/f
t
72.
2
pF/
m

507243

Coa
x
Cab
le

N/
A

N/A

PS
helix

None

N/A

N/A

Al
tube

1.6
25
in
41.
28
mm

BC
tube

N/A

N/A

N/A

BC
tube

N/A

244

245

507244

507245

Coa
x
Cab
le

Coa
x
Cab
le

75

15.
5
pF/f
t
50.
9
pF/
m

75

15.
5
pF/f
t
50.
9
pF/
m

PS
helix

None

Al
tube

0.8
75
in
22.
23
mm

PS
helix

PEIIIA

Al
tube

1.0
15

246

507246

Coa
x
Cab
le

75

15.
5
pF/f
t
50.
9
pF/
m

247

507247

Coa
x

75

15.
5

PS
helix

PS
helix

None

PEIIIA

Al
tube

0.5
00
in
12.
70
mm

0.102
BC

Al
tube

0.6
00
in
15.
24
mm

0.102
BC

0.188
BC

0.188
BC

Cab
le

248

507248

Coa
x
Cab
le

249

507249

Coa
x
Cab
le

250

507250

Coa
x
Cab
le

pF/f
t
50.
9
pF/
m

75

15.
0
pF/f
t
49.
2
pF/
m

75

15.
0
pF/f
t
49.
2
pF/
m

75

15.
0
pF/f
t

in
25.
78
mm

PS
helix

PS
helix

PS
helix

Al
tube

1.6
25
in
41.
28
mm

0.370
BC

PEIIIA

Al
tube

1.7
65
in
44.
83
mm

0.370
BC

None

Al
tube

None

3.1
25
in
79.

0.732
BC

49.
2
pF/
m

251

252

253

507251

Coa
x
Cab
le

507252

Coa
x
Cab
le

507253

Coa
x
Cab
le

75

15.
0
pF/f
t
49.
2
pF/
m

75

24.
4
pF/f
t
80.
1
pF/
m

75

24.
4
pF/f
t
80.
1

38
mm

PS
helix

PE
tube

PE
tube

PEIIIA

None

PE

Al
tube

3.2
95
in
83.
69
mm

0.732
BC

Al
tube

0.5
30
in
13.
46
mm

0.167
BC

Al
tube

0.6
35
ma
x.
in
16.

0.167
BC

pF/
m

254

507254

Coa
x
Cab
le

255

507255

Coa
x
Cab
le

256

507256

Coa
x
Cab
le

50

24.
4
pF/f
t
80.
1
pF/
m

50

24.
4
pF/f
t
80.
1
pF/
m

50

23.
5
pF/f
t

1
ma
x.
mm

PE
tube

PE
tube

TFE
tube

Al
tube

1.1
00
ma
x.
in
27.
94
ma
x.
mm

0.311
BC

None

Al
tube

0.9
53
in
24.
21
mm

0.311
BC

None

Al
tube

PE

0.9
53
in
24.

S tube

77.
1
pF/
m

257

507257

Coa
x
Cab
le

50

24.
4
pF/f
t
80.
1
pF/
m

24.
4
pF/f
t
80.
1
pF/
m

258

507258

Coa
x
Cab
le

50

259

507259

Coa
x
Cab
le

50

23.
5
pF/f
t

21
mm

PS
tube

PE
tube

TFE
tube

Al
tube

1.7
86
in
45.
36
mm

BC
tube

PE

Al
tube

1.9
36
ma
x.
in
49.
17
ma
x.
mm

BC
tube

None

Al
tube

None

0.3
90
in
9.9

0.115
BC

77.
1
pF/
m

260

261

262

507260

507261

507262

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

50

23.
5
pF/f
t
77.
1
pF/
m

50

23.
5
pF/f
t
77.
1
pF/
m

50

23.
5
pF/f
t
77.
1

1
mm

PE
tube

PE
tube

PE
tube

PEIIIA

None

PE

Al
tube

0.4
50
in
11.
4
mm

0.115
BC

Al
tube

3.3
70
in
85.
60
mm

BC
tube

Al
tube

3.5
20
in
89.
41
mm

BC
tube

pF/
m

263

264

264
A

507263

507264

507264
A

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

50

21.
5
pF/f
t
70.
5
pF/
m

40

38.
0
pF/f
t
125
pF/
m

40

38.
0
pF/f
t
125
pF/
m

Air
spac
e
TFE

PE

PE

None

Al
tube

0.5
00
in
12.
7
mm

PVCIIA

2
BC
2
TC

0.7
50
in
19.
1
mm

4x
19/27
BC

2
BC
2
TC

0.7
50
in
19.
1
mm

4x
19/27
BC

PU

0.172
BC

264
B

264
C

265

507264
B

507264
C

507265

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

40

42.
0
ma
x.
pF/f
t
138
ma
x.
pF/
m

40

42.
0
ma
x.
pF/f
t
138
ma
x.
pF/
m

50

22.
3
pF/f
t
73.
2
pF/

PE

PE

PS
helix

PU

2
BC
2
TC

0.7
50
in
19.
1
mm

4x
19/27
BC

PU

2
BC
2
TC

0.7
50
in
19.
1
mm

2 x 13
BC 2 x
13 TC

CC
S
tube

2.0
70
in
52.
58
mm

BC
tube

PEIIIA

266
*

267

268

507266

507267

507268

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

15
30

53.
0
pF/f
t
174
pF/
m

50

22.
2
pF/f
t
72.
8
pF/
m

50

23.
0
pF/f
t
75.
5
pF/
m

PE

PS
helix

PS
helix

PVCI

PE-III

None

BC

0.4
00
in
10.
2
mm

0.144
BC
helix

CC
S
tube

1.1
90
in
30.
23
mm

BC
tube

BC
Tub
e

0.5
00
in
12.
7
mm

0.160
BC

507
269

269

Coax
Cable

22.2
pF/ft
72.8
pF/m

50

PS
helix

1.0
05
in
25.
53
mm

BC
Tube

None

BC
tub
e

BC
Tub
e

1.8
30
in
46.
48
mm

BC
tube

270

507-270

Coax
Cable

50

22.3
pF/ft
73.2
pF/m

271

507-271

Waveguid
e

N/A

N/A

N/A

N/A

N/A

N/A

N/A

272

507-272

Waveguid
e

N/A

N/A

N/A

N/A

N/A

N/A

N/A

273

507-273

Waveguid
e

N/A

N/A

N/A

N/A

N/A

N/A

N/A

274

507-274

Waveguid
e

N/A

N/A

N/A

N/A

N/A

N/A

N/A

275

507-275

Waveguid
e

N/A

N/A

N/A

N/A

N/A

N/A

N/A

276

507-276

Waveguid
e

N/A

N/A

N/A

N/A

N/A

N/A

N/A

277

507-277

Waveguid
e

N/A

N/A

N/A

N/A

N/A

N/A

N/A

PS helix

None

278

279*

280*

281

282

507-278

507-279

507-280

507-281

507-282

Waveguid
e

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

283

507-283

Coax
Cable

284A

507284A

Coax
Cable

N/A

N/A

75

17.0
pF/ft
55.8
pF/m

50

25.4
pF/ft
83.3
pF/m

50

25.4
pF/ft
83.3
pF/m

54.6

28.2
pF/ft
92.5
pF/m

N/A

Air
space
TFE

Taped
TFE

Taped
TFE

Irradiate
d PE

N/A

FG-V

FEP-IX

SR & braid

FEP

N/A

N/A

N/A

0.1
45
in
3.6
8
mm

19/36
SCCS

2S

0.4
80
in
12.
2
mm

0.1144
BC

2S

0.7
50
in
19.
1
mm

19/0.0
378 S

2S

0.2
00
in
5.0
8
mm

0.0253
S

19/0.1
77 S

0.220
BC

46

50.0
pF/ft
164
pF/m

Rubber

Rubber-IV

2S

0.4
75
ma
x. in
12.
1
ma
x.
mm

75

15.0
pF/ft

PE helix

None

BC
Tub

1.0
05

49.2
pF/m

285A

286

287

288

507285A

507-286

507-287

507-288

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

in
25.
53
mm

BC
Tub
e

1.0
05
in
25.
53
mm

0.1140
BC

BC
Tub
e

1.8
30
in
46.
48
mm

BC
tube

BC
Tub
e

1.8
30
in
46.
48
mm

0.197
BC

CCS
tube

3.7
50
in
95.
25
mm

BC
tube

CCS
tube

N/A

100

13.0
pF/ft
42.7
pF/m

75

15.1
pF/ft
49.5
pF/m

100

13.5
pF/ft
44.3
pF/m

50

21.6
pF/ft
70.9
pF/m

PE helix

None

CCS
tube

3.7
50
in
95.
25
mm

N/A

N/A

N/A

N/A

289

507-289

Coax
Cable

75

14.7
pF/ft
48.2
pF/m

290

507-290

Waveguid
e

N/A

N/A

TFE
helix

PE helix

PE helix

PE helix

None

None

None

None

291

292

293

293A

294

294A

295

507-291

507-292

507-293

507293A

507-294

507294A

507-295

Waveguid
e

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

N/A

N/A

75

15.1
pF/ft
49.5
pF/m

50

30.8
pF/ft
101
pF/m

50

30.8
pF/ft
101
pF/m

95

16.3
pF/ft
53.5
pF/m

95

16.3
pF/ft
53.5
pF/m

50

30.8
pF/ft
101
pF/m

N/A

PE helix

PE

PE

PE

PE

PE

N/A

PE FC

PE-IIIA

PE-IIIA

PE-IIIA

PE-IIIA

PE-IIIA

N/A

N/A

N/A

BC
Tub
e

1.8
30
in
46.
48
mm

BC
tube

0.5
45
in
13.
8
mm

0.106
BC

0.5
45
in
13.
8
mm

0.106
BC

TC

0.6
30
in
16.
0
mm

0.0808
BC
0.0808
TC

0.6
30
in
16.
0
mm

0.0808
BC
0.0808
TC

0.8
95
in
22.
7

0.195
BC

mm

296*

297

298

301*

507-296

507-297

507-298

507-301

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

302*

507-302

Coax
Cable

303*

507-303

Coax
Cable

50

36.4
pF/ft
119
pF/m

50

21.4
pF/ft
70.2
pF/m

N/A

N/A

50

32.0
pF/ft
105
pF/m

Silicone
rubber

TFE
helix

PE

TFE

Neoprene

None

PE foam

FEP-IX

1.1
90
in
30.
23
mm

37/0.0
336 S

BC
Tub
e

1.0
05
in
25.
53
mm

BC
tube

Non
e

0.6
50
in
16.
5
mm

7/24
CCS

HR

0.2
45
in
6.2
2
mm

7/0.02
03 HR

0.025
SCCS

0.039
SCCS

75

19.5
pF/ft
64.0
pF/m

TFE

FEP-IX

0.2
06
ma
x. in
5.2
3
ma
x.
mm

50

29.4
pF/ft
96.5

TFE

FEP-IX

0.1
70
in

pF/m

304*

305

306A

307A*

507-304

507-305

507306A

507307A

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

50

29.4
pF/ft
96.5
pF/m

75

19.5
pF/ft
64.0
pF/m

75

16.9
pF/ft
55.4
pF/m

4.3
2
mm

TFE

FEP

PE foam

FEP-IX

PE-IIIA

PE-IIIA

2S

0.2
80
in
7.1
1
mm

0.059
SCCS

BC
Tub
e

1.9
90
in
50.
55
mm

BC
tube

AL
Tub
e

1.0
15
in
25.
78
mm

0.173
BC

2S

0.2
70
ma
x. in
6.8
6
ma
x.
mm

19/0.0
058 S

7/0.00
67
SCCS

2 cond.

75

16.7
pF/ft
54.8
pF/m

TFE

FEP-IX

0.0
98
in
2.4
9
mm

FEP

Neoprene

TC

0.7

316*

507-316

Coax
Cable

50

29.4
pF/ft
96.5
pF/m

317

507-317

Coax

95

15.4

PE foam

PE-IIIA

Cable

318

319

321

322

507-318

507-319

507-321

507-322

Coax
Cable

Coax
Cable

Coax
Cable

Coax
Cable

pF/ft
50.5
pF/m

10
in
18.
0
mm

7/0.02
9 BC

BC
Tub
e

1.1
00
in
27.
94
mm

BC
tube
O.D.
0.3580
I.D.
0.2870

BC
Tub
e

1.9
70
in
50.
04
mm

BC
tube
O.D.
0.6880
I.D.
0.5880

BC
Tub
e

2.8
50
in
72.
39
mm

BC
tube

BC
Tub
e

3.0
40
in
77.
22
mm

BC
tube

BC
tube

BC
tube

50

22.2
pF/ft
72.8
pF/m

50

22.3
pF/ft
73.2
pF/m

50

21.7
pF/ft
71.2
pF/m

50

21.7
pF/ft
71.2
pF/m

PE foam

PE FC

BC
Tub
e

1.0
60
in
26.
92
mm

PE foam

None

BC
Tub

0.9
80

323

507-323

Coax
Cable

50

25.6
pF/ft
84.0
pF/m

324

507-324

Coax
Cable

50

25.6
pF/ft

PE helix

SS PS

SS PE

SS PE

PE-IIIA

PE-IIIA

None

PE FC

84.0
pF/m

325

326

327

32
8*

50
732
8

Coax
Cable

507-325

Coax
Cable

507-326

507-327

Coax
Cable

Coa
x
Cab
le

85.
0
pF/f
t
278
.9
pF/

25

50

50

50

Rubbe
re

26.3
pF/ft
86.3
pF/m

26.3
pF/ft
86.3
pF/m

26.3
pF/ft
86.3
pF/m

Neopren
e

PE
spline

PU

PE
spline

PU

PE
spline

TC,
GS,
TC

PU

1.4
60
in
37.
08
mm

TC
braid

in
24.
9
mm

2
SC
strip

0.4
65
ma
x. in
11.
8
ma
x.
mm

19/0.0
200
SCCA

2
SC
strip

0.7
79
ma
x. in
19.
8
ma
x.
mm

19/0.0
400
SCCA

2
SC
strip

1.1
8
ma
x. in
30.
0
ma
x.
mm

19/0.0
640
SCCA

32
9*

33
0

33
1

50
732
9

50
733
0

50
733
1

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

33
2

50
733
2

Coa
x
Cab
le

33
3

50
733
3

Coa
x
Cab
le

50

50.
0
pF/
ft
164
pF/
m

50

25.
0
pF/
ft
82.
0
pF/
m

50

25.
0
pF/
ft
82.
0
pF/
m

50

25.
0
pF/
ft
82.
0
pF/
m

50

25.
0
pF/
ft
82.
0

Rubb
er

PE
foam

PE
foam

PE
foam

PE
foam

Neopren
e

None

PE-IIIA

None

PE-IIIA

TC,
GS,
TC

0.7
00
in
17.
8
mm

19/0.01
17 TC

SC

0.2
42
in
6.1
5
mm

SC

Al
tub
e

0.6
25
in
15.
9
mm

0.162
BC

Al
tub
e

0.8
75
in
22.
2
mm

0.288
BC

Al
tub
e

1.0
52
max
. in
26.
72

0.288
BC

pF/
m

33
4

33
5

33
6

50
733
4

50
733
5

50
733
6

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

max
.
mm

75

17.
0
pF/
ft
55.
8
pF/
m

75

17.
0
pF/
ft
55.
8
pF/
m

75

16.
5
pF/
ft
54.
1
pF/
m

PE
foam

PE-IIIA

Al
tub
e

0.8
25
in
21.
0
mm

PE
foam

PE-IIIA

BC
Tub
e

0.6
20
in

36
0

50
736
0

Coa
x
Cab
le

50

25.
0
pF/
ft
82.
0
pF/
m

36
6

50
736

Coa
x
Cab

50

26.
6
pF/

PE
foam

PE
foam

PE
foam

None

PE-IIIA

None

Al
tub
e

0.5
00
in
12.
7
mm

0.098
BC

Al
tub
e

0.6
25
in
15.
9
mm

0.098
BC

Al
tub
e

0.8
75
in
22.
2
mm

0.173
BC

0.243
BC

0.160
BC

36
7

36
9

50
736
7

50
736
9

le

Coa
x
Cab
le

Coa
x
Cab
le

ft
87.
3
pF/
m

50

21.
7
pF/
ft
71.
2
pF/
m

50

23.
5
pF/
ft
77.
1
pF/
m

50

24.
0
pF/
ft
78.
7
pF/
m

15.
7
mm

PE
helix

PE
tubes

PE-IIIA

PE-IIIA

BC
Tub
e

5.2
00
in
132
.1
mm

BC
tube

Al
tub
e

0.4
70
in
11.
9
mm

0.177
BC

Al
tub
e

0.3
90
in
9.9
1
mm

0.177
BC

0.0508
BC

0.0285
BC

37
0

50
737
0

Coa
x
Cab
le

37
3

50
737
3

Coa
x
Cab
le

N/
A

N/A

PE

PE foam

No
ne

0.6
50
in
16.
5
mm

37
4

50
737

Coa
x
Cab

N/
A

N/A

PE

PE foam

No
ne

0.6
50
in

PE
tubes

None

37
6

37
7

50
737
6

50
737
7

le

Coa
x
Cab
le

Coa
x
Cab
le

16.
5
mm

50

26.
0
pF/
ft
85.
3
pF/
m

50

24.
0
pF/
ft
78.
7
pF/
m

PE
helix

PE-IIIA

Al
tub
e

2.0
00
in
50.
8
mm

N/A

N/A

N/A

N/A

N/A

No
ne

0.6
50
in
16.
5
mm

2 cond.
0.0403

37
8

50
737
8

Coa
x
Cab
le

50

22.
1
pF/
ft
72.
5
pF/
m

38
2

50
738
2

Rigi
d
Line

N/
A

N/A

38
3

50
738
3

Coa
x
Cab
le

10
0

N/A

PE
foam

TFE
tubes

PE

PE-IIIA

None

PE foam

Al
tub
e

1.0
60
in
26.
9
mm

0.312
BC
tube

Al
tub
e

0.5
30
in
13.
5
mm

0.165
S tube

BC
tube

38
4

50
738
4

Coa
x
Cab
le

38
5

50
738
5

Coa
x
Cab
le

38
6

50
738
6

Coa
x
Cab
le

38
8

50
738
8

Coa
x
Cab
le

50

30.
8
pF/
ft
101
pF/
m

50

25.
4
pF/
ft
83.
3
pF/
m

PE

SS
TFE

PE foam

Optional

Flat
BC

0.6
50
in
16.
5
mm

0.16
BC

AL
Tub
e

0.6
60
in
16.
8
mm

0.153
S

No
ne

0.6
50
in
16.
5
mm

0.0508
CCS

0.5
45
in
13.
8
mm

0.1020
BC

0.250
BC AL

7/26
TC

N/
A

N/A

50

30.
8
pF/
ft
101
pF/
m

PE

PE-IIIA

2S

0.8
75
in
22.
2
mm

C PE
& PE

PVC-IIA

TC

0.4
05

38
9

50
738
9

Coa
x
Cab
le

50

22.
8
pF/
ft
74.
8
pF/
m

39
1*

50
7-

Coa
x

72

23.
0

PE

PE

PE foam

PE-IIIA

39
1

39
2*

39
3*

40
0*

40
1*

50
739
2

50
739
3

50
740
0

50
740
1

Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

pF/
ft
75.
5
pF/
m

72

23.
0
pF/
ft
75.
5
pF/
m

50

29.
4
pF/
ft
96.
5
pF/
m

50

29.
4
pF/
ft
96.
5
pF/
m

50

29.
4
pF/
ft
96.
5
pF/
m

in
10.
3
mm

C PE
& PE

TFE

TFE

TFE

PVC-IIA

FEP-IX

FEP-IX

None

TC

0.4
75
in
12.
1
mm

7/26
TC

2S

0.3
90
in
9.9
mm

7/0.031
2S

2S

0.1
95
in
4.9
5
mm

19/0.00
77 S

BC
Tub
e

0.2
50
in
6.3
5
mm

0.0641
S

40
2*

40
3*

40
4*

40
5*

50
740
2

50
740
3

50
740
4

50
740
5

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

Coa
x
Cab
le

50

29.
4
pF/
ft
96.
5
pF/
m

50

29.
4
pF/
ft
96.
5
pF/
m

50

31.
5
pF/
ft
103
pF/
m

50

29.
4
pF/
ft
96.
5
pF/
m

TFE

TFE

TFE

TFE

None

FEP-IX

FEP-IX

None

BC
Tub
e

0.1
41
in
3.5
8
mm

0.0360
SCCS

2S

0.1
04
in
2.6
4
mm

7/38
SCCS

0.0
75
max
. in
0.1
91
max
.
mm

7/38
SCCS

BC
Tub
e

0.0
86
in
2.1
8
mm

0.0201
SCCS

Coax Cable Specifications


Type

Specifications

Image

A low loss cable with a non-contaminating jacket

RG213

Impedance: 50 ohms

Power Handling: 1800


watts 30 MHz and less

Attenuation: 1.2 dB per 100 ft at 30 MHz and less

RG214

A low loss cable with double braid and noncontaminating jacket

Impedance: 50 ohms

Power Handling: 1800


watts 30 MHz and less

Attenuation: 1.2 dB per 100 ft at 30 MHz and less


This coax cable provides excellent performance for high
power HF needs or VHF/UHF applications. Because of its
solid center conductor, it is rather stiff -- but there is a
more flexible version, it's called LMR-400 Ultra-flex.

LMR400
Impedance: 50 ohms

Power Handling: 2100


watts 30 MHz and less

Attenuation: 0.7 dB per 100 ft at 30 MHz and less


This coax cable provides excellent performance for high
power HF needs or VHF/UHF applications. Because of its
solid center conductor, it is rather stiff

9913
Impedance: 50 ohms

Power Handling: 2200


watts 30 MHz and less

Attenuation: 0.8 dB per 100 ft at 30 MHz and less

RG8X

A very flexible cable suitable for HF transmit


applications where an amplifier is not used.
Impedance: 50 ohms

Attenuation: 2.0 dB per 100 ft at 30 MHz and less


This economically priced coax cable is suitable for HF
applications where high power and long runs are not
required.

RG58U
Impedance: 50 ohms
Attenuation: 2.5 dB per 100 ft at 30 MHz and less
While not a coax cable, it seemed appropriate to include a reference to Ladder Line on this page as well

Ladder
Line

There are three common versions of this 450 ohm


'windowed' line: 18 AWG, solid copper-clad steel (30%)
conductors, poly-clad; 16 AWG, 19 strand copper-clad
steel conductors, poly-clad and 18 AWG, 16 strand
copper-clad steel conductors, poly-clad.

Impedance: 450 ohms

Attenuation: NA

Power Handling: 1500


watts at 30 MHz and less
for the 18 AWG and the16
AWG variety