Time Delay
(ns/ft)
Dielectric Type
Solid Polyethylene (PE)
Foam Polyethylene (FE)
Foam Polystyrene (FS)
Air Space Polyethylene (ASP)
Solid Teflon (ST)
Air Space Teflon (AST)
1.54
1.27
1.12
1.15-1.21
1.46
1.13-1.20
Propagation
Velocity
(% of c)
65.9
80.0
91.0
84-88
69.4
85-90
MIL-W-17
/2-RG6
/2-RG6
/6-RG11
/6-RG11
/6-RG12
/6-RG12
/15-RG22
/15-RG22
/16-RG23
/16-RG24
/24-RG34
/24-RG34
/64-RG35
/64-RG35
/28-RG58
/28-RG58
Dielectric
Type
Z0()
50.0
52.5
50.0
76.0
75.0
52.0
52.0
51.0
51.0
50.0
52.0
52.0
75.0
75.0
75.0
75.0
52.0
95.0
95.0
125.0
125.0
71.0
75.0
71.0
75.0
53.5
53.5
52.0
53.5
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
Capacitance
(pF/ft)
30.8
28.5
30.8
20.0
20.6
29.6
29.6
30.2
30.2
30.8
29.6
29.6
20.6
20.6
20.6
20.6
29.6
16.3
16.3
12.0
12.0
21.7
20.6
21.7
20.6
28.8
28.8
29.6
28.8
O.D.
(in.)
0.226
0.332
0.328
0.332
0.332
0.405
0.405
0.420
0.420
0.420
0.463
0.463
0.405
0.405
0.463
0.463
0.870
0.405
0.420
0.650
0.708
0.625
0.630
0.928
0.928
0.200
0.195
0.195
0.195
dB/100 ft
@400 MHz
11.7
7.0
6.5
7.4
6.5
6.0
6.0
5.9
6.1
6.1
6.0
6.0
5.7
5.2
5.7
5.2
2.8
10.5
10.5
5.2
5.2
5.3
5.3
2.8
2.8
11.7
11.7
13.2
14.0
Vmax
(rms)
1,900
3,000
3,000
2,700
2,700
4,000
5,000
4,000
4,000
5,000
4,000
5,000
4,000
5,000
4,000
5,000
11,000
1,000
1,000
3,000
3,000
5,200
6,500
10,000
10,000
1,900
1,900
1,900
1,900
Shield
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
RG-58C
RG-59/A
RG-59B
RG-62/A/B
RG-63/A/B
RG-65/A
RG-71/A/B
RG-79/A/B
RG-83
RG-88
RG-108/A
RG-111/A
RG-114/A
RG-119
RG-120
RG-122
RG-130
RG-131
RG-133/A
RG-141/A
RG-142/A/B
RG-144
RG-164
RG-165
RG-166
RG-174
RG-177
RG-178/A/B
RG-179
RG-179A/B
RG-180
RG-180A/B
RG-210
RG-211/A
RG-212
RG-213
RG-214
RG-215
RG-216
RG-217
RG-218
RG-219
RG-223
RG-302
RG-303
RG-304
RG-307/A
RG-316
RG-391
RG-392
/28-RG58
/29-RG59
/29-RG59
/30-RG62
/31-RG63
/34-RG65
/90-RG71
/31-RG79
/45-RG108
/15-RG111
/47-RG114
/52-RG119
/52-RG120
/54-RG122
/56-RG130
/56-RG131
/100-RG133
/60-RG142
/62-RG144
/64-RG164
/65-RG165
/65-RG166
/67-RG177
/93-RG178
/94-RG179
/94-RG179
/95-RG180
/95-RG180
/97-RG210
/72-RG211
/73-RG212
/74-RG213
/75-RG214
/74-RG215
/77-RG216
/78-RG217
/79-RG218
/79-RG219
/84-RG223
/110-RG302
/111-RG303
/112-RG304
/116-RG307
/113-RG316
/126-RG391
/126-RG392
50.0
73.0
75.0
93.0
125.0
950.0
93.0
125.0
35.0
48.0
78.0
95.0
185.0
50.0
50.0
50.0
95.0
95.0
95.0
50.0
50.0
75.0
75.0
50.0
50.0
50.0
50.0
50.0
70.0
75.0
93.0
95.0
93.0
50.0
50.0
50.0
50.0
50.0
75.0
50.0
50.0
50.0
50.0
75.0
50.0
50.0
75.0
50.0
72.0
72.0
PE
PE
PE
ASP
ASP
ASP
ASP
ASP
PE
PE
PE
ASP
ST
ST
PE
PE
PE
PE
ST
ST
ST
PE
ST
ST
PE
ST
ST
ST
ST
ST
ASP
ST
PE
PE
PE
PE
PE
PE
PE
PE
PE
ST
ST
ST
80
ST
30.8
21.1
20.6
13.5
10.0
44.0
13.5
10.0
44.0
50.0
19.7
16.3
6.5
29.4
29.4
30.8
17.0
17.0
16.3
29.4
29.4
19.5
20.6
29.4
29.4
30.5
30.8
29.4
20.9
19.5
15.4
15.4
13.5
29.4
29.4
30.8
30.8
30.8
20.6
30.8
30.8
30.8
19.8
19.5
29.4
29.4
16.9
29.4
23.0
23.0
0.195
0.242
0.242
0.242
0.405
0.405
0.245
0.436
0.405
0.515
0.235
0.478
0.405
0.465
0.523
0.160
0.625
0.683
0.405
0.190
0.195
0.410
0.870
0.410
0.460
0.110
0.895
0.072
0.100
0.100
0.140
0.140
0.242
0.730
0.332
0.405
0.425
0.463
0.425
0.545
0.870
0.928
0.211
0.201
0.170
0.280
0.270
0.102
0.405
0.475
14.0
10.5
9.0
8.0
5.5
16 @5MHz
8.0
5.5
9.0
0.7 @1MHz
2.8 @10MHz
10.5
8.5
3.8
3.8
18.0
8.8
8.8
5.7
9.0
9.0
4.5
2.8
5.0
5.0
14.7
2.8
29.0
21.0
21.0
17.0
17.0
8.0
2.3
6.5
5.5
5.5
5.5
5.2
4.3
2.5
2.5
8.8
8.0
9.0
6.0
7.5
20.0
15.0
15.0
1,900
2,300
2,300
750
1,000
1,000
750
1,000
2,000
10,000
1,000
1,000
1,000
6,000
6,000
1,900
3,000
3,000
4,000
1,900
1,900
5,000
10,000
5,000
5,000
11,000
1,000
1,200
1,200
1,500
1,500
750
7,000
3,000
5,000
5,000
5,000
5,000
7,000
11,000
11,000
1,900
2,300
1,900
3,000
1,000
1,200
5,000
5,000
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
Dbl Braid
Braid
Braid
Braid
Braid
Braid
Dbl Braid
Braid
Braid
Braid
Braid
Braid
Braid
Braid
RG-393
RG-400
RG-401
RG-402
RG-403
RG-405
9914 (Belden)
/127-RG393
/128-RG400
/129-RG401
/130-RG402
/131-RG403
/133-RG405
50.0
50.0
50.0
50.0
50.0
50.0
50.0
ST
ST
ST
ST
ST
ST
29.4
29.4
29.4
29.4
29.4
29.4
26.0
0.390
0.195
0.250
0.141
0.116
0.086
0.405
5.0
9.6
4.6
7.2
29.0
13.0
10.0
5,000
1,900
3,000
2,500
2,500
1,500
------
Braid
Braid
Cu. S-R
Cu. S-R
Braid
Cu. S-R
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
shield
s
max
comments
attenuation
@ 750 MHz
75
1.0 mm
PF
0.75
0.185
4.7
0.270
6.86
double
television,satellite
05.65dB/100 ft
75
PF
0.298
7.57
quad
05.65dB/100 ft
[1
5]
75
1.30 mm
PF
0.225
5.72
0.320
8.13
double
television,satellite
04.57dB/100 ft
RG-8/U
50
2.17 mm
PE
RG-8X
50
1.0 mm
PF
0.75
0.285
7.2
0.405
10.3
0.185
4.7
0.242
6.1
double
05.967
dB/100 ft
[16]
10.946
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
shield
s
max
comments
attenuation
@ 750 MHz
characteristics of RG-8U
dB/100 ft
[16]
in a diameter similar to
RG-6.
RG-9/U
51
RG-11/U
75
RG-56/U
48
PE
1.63 mm
PE
0.66
0.285
7.2
1.4859 m
0.420
10.7
0.412
10.5
[17]
underground conduit
[18]
03.65dB/100 ft
Used for
radiocommunication
and amateur radio, thin
RG-58/U
50
0.81 mm
PE
0.66
0.116
2.9
0.195
5.0
single
Ethernet (10BASE2)
and NIMelectronics,
Loss 1.056 dB/meter @
2.4 GHz. Common.
[19]
13.104
dB/100 ft
[16]
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
shield
s
max
comments
attenuation
@ 750 MHz
Used to
carry baseband video
in closed-circuit
television, previously
RG-59/U
75
0.81 mm
PE
0.66
0.146
3.7
0.242
6.1
single
[20]
75
0.50 mm
PE
0.85
3.0
5.4
single
video observation
systems, and other. PVC
jacket.
75
0.80 mm
PE
0.82 +/-2
0.181
4.6
0.256
6.5
double
monitoring system,
CCTV feeder lines,
wiring between the
camera and control unit
09.708
dB/100 ft
[16]
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
shield
s
max
comments
attenuation
@ 750 MHz
50
1.024 mm
PE
0.425
10.8
single
92
PF
0.84
0.242
6.1
single
automotive radio
antennas.
RG-62A
93
RG-142
50
RG-174/U
50
ASP
7x0.16 m
m
PE
0.242
0.66
0.059
1.5
0.100
[21]
6.1
single
4.95
double
RG-142.pdf
2.55
single
23.565
dB/100 ft
[16]
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
shield
s
max
comments
attenuation
@ 750 MHz
70.1 mm
RG-178/U
50
(Ag-plated
Cu-clad
PTFE
0.69
0.033
0.84
0.071
1.8
single
PTFE
0.67
0.063
1.6
0.098
2.5
single
Steel)
70.1 mm
RG-179/U
75
(Ag-plated
[24]
VGA RGBHV
Cu)
0.0120 in
RG180B/U
95
(Ag-plated
Cu-clad
steel)
single Ag
PTFE
0.102
2.59
0.145
3.68
covered
Cu
VGA RGBHV
[22]
42.7 dB/100 ft
[23]
@ 900 MHz
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
shield
s
max
comments
attenuation
@ 750 MHz
For radiocommunication
RG-213/U
50
70.0296
in Cu
0.66
0.285
7.2
0.405
10.3
single
RG-214/U
50
70.0296
in
PE
0.66
0.285
7.2
0.425
10.8
double
05.967
dB/100 ft
[16]
[25]
[26]
06.702
dB/100 ft
[16]
50
0.195 in
Cu
PE
0.66
0.660
16.76
(0.680?)
(17.27?)
22
single
(2.5dB/100' @
400 MHz), 11kV
02.834
dB/100 ft
[16]
dielectric withstand.
Silver-plated
RG-223/U
50
0.88 mm
PE
0.66
0.0815
2.07
0.212
5.4
double
11.461
dB/100 ft
[16]
impedanc
type
core
ohms
RG-316/U
RG-400/U
50
50
7x0.0067
in
19x0.20m
m
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
max
shield
comments
attenuation
@ 750 MHz
0.695
0.060
1.5
0.098
2.6
single
connectors
in NIMelectronics;
PTFE
2.95
4.95
double
[27]
[28]
22.452
dB/100 ft
[16]
12.566
dB/100 ft
[16]
50
19 x
0.28 mm
0.79
5.4
frequency for
radiocommunication
and amateur radio
50
frequency for
0.82
radiocommunication
and amateur radio
LMR-100
50
2.79
low loss
communications, 1.36
20.725
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
max
shield
comments
attenuation
@ 750 MHz
dB/100 ft
[16]
low loss
communications, 0.620
LMR-195
50
4.95
dB/meter @
2.4 GHz LMR195specs.
10.125
dB/100 ft
[16]
LMR-200
HDF-200
50
CFD-200
LMR-240
50
LMR-400
HDF-400
CFD-400
1.12 mm
Cu
1.42 mm
Cu
low loss
PF
0.83
0.116
2.95
0.195
4.95
0.84
0.150
3.81
0.240
6.1
(Cu-clad
Al)
double
low loss
PF
0.85
0.285
7.24
0.405
10.29
09.035
dB/100 ft
communications, 0.223
[30]
[16]
06.877
dB/100 ft
[29]
8X
2.74 mm
50
communications, 0.554
[16]
03.544
dB/100 ft
[16]
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
shield
s
4.47 mm
LMR-600
50
(Cu-clad
LMR-900
LMR-1200
LMR-1700
QR-320
50
50
50
75
(BC tube)
8.86 mm
(BC tube)
13.39 mm
(BC tube)
1.80 mm
comments
PF
0.87
0.455
11.56
0.590
14.99
communications, 0.144
dB/meter @ 2.4 GHz
low loss
PF
0.87
0.680
17.27
0.870
22.10
communications, 0.098
dB/meter @ 2.4 GHz
low loss
PF
0.88
0.920
23.37
1.200
30.48
communications, 0.075
dB/meter @ 2.4 GHz
low loss
PF
0.89
1.350
34.29
1.670
42.42
communications, 0.056
dB/meter @ 2.4 GHz
PF
0.395
10.03
single
attenuation
@ 750 MHz
low loss
Al)
6.65 mm
max
02.264
dB/100 ft
[16]
01.537
dB/100 ft
[16]
01.143
dB/100 ft
[16]
0.844
dB/100 ft
[16]
03.34dB/100 ft
impedanc
type
core
ohms
Dielectri
Dielectri
Dielectri
Dielectri
c Type
c VF
c in
c mm
OD
in
shield
s
max
comments
attenuation
@ 750 MHz
applications
QR-540
75
3.15 mm
PF
0.610
15.49
single
01.85dB/100 ft
QR-715
75
4.22 mm
PF
0.785
19.94
single
01.49dB/100 ft
QR-860
75
5.16 mm
PF
0.960
24.38
single
01.24dB/100 ft
QR-1125
75
6.68 mm
PF
1.225
31.12
single
01.01dB/100 ft
Conductor
Dia.
Over
Ins.
Braid Shield
Inner
Outer
Nom.
O.D.
Jacket
Material
Nom.
Imped.
Nominal
Capacitance
Nominal
Attenuation
ohm
pF/m
dB/km
No./mm
MTRL
mm
No./mm
No./mm
mm
RG-5/U
1/1.29
BC
4.7
16/9/0.16
16/9/0.16
8.4
PVC
52.5
93.5
85
RG-7/U
1/0.914
BC
6.35
24/7/0.18
9.4
PVC
94.5
41
66
RG-8/U
7/0.724
BC
7.24
24/8/0.18
10.3
PVC
52
96.8
69
RG-8A/U
7/0.724
BC
7.24
24/8/0.18
10.3
NC.PVC
52
96.8
69
RG-11/U
7/0.404
TC
7.24
24/8/0.18
10.3
PVC
75
67.3
76
RG-11A/U
7/0.404
TC
7.24
24/8/0.18
10.3
NC.PVC
75
67.3
76
RG-13/U
7/0.404
TC
7.11
24/9/0.16
24/8/0.16
10.7
PVC
74
67.3
76
RG-13A/U
7/0.404
TC
7.11
24/9/0.16
24/8/0.16
10.7
NC.PVC
74
67.3
76
RG-14/U
1/2.59
BC
9.4
24/10/0.18
24/8/0.18
13.8
PVC
52
96.8
46
RG-14A/U
1/2.59
BC
9.4
24/10/0.18
24/8/0.18
13.8
NC.PVC
52
96.8
46
RG-15/U
1/1.45
CCS
9.4
24/10/0.18
24/8/0.18
13.8
PVC
76
65.6
49
RG-17/U
1/1.478
BC
17.3
24/14/0.26
22.1
PVC
52
96.8
28
RG-17A/U
1/4.78
BC
17.3
24/14/0.26
22.1
NC.PVC
52
96.8
28
RG-19/U
1/6.35
BC
23.1
36/12/0.26
28.5
PVC
52
96.8
22
RG-19A/U
1/6.35
BC
23.1
36/12/0.26
28.5
NC.PVC
52
96.8
22
RG-22/U
7/0.386*2C
BC
7.24
24/8/0.18
10.3
PVC
95
52.5
118
RG-22A/U
7/0.386*2C
BC
7.24
24/8/0.16
24/8/0.16
10.7
PVC
95
52.5
118
RG-22B/U
7/0.386*2C
BC
7.24
24/8/0.16
24/8/0.16
10.7
NC.PVC
95
52.5
118
RG-29/U
1/0.813
BC
2.95
16/7/0.127
4.7
PE
53.52.5
93.5
138
RG-34/U
7/0.724
BC
11.6
24/9/0.16
15.9
PVC
713
70.5
46
RG-34B/U
7/0.632
BC
11.7
24/10/0.18
16
NC.PVC
753
67
48
RG-54A/U
7/0.385
BC
4.52
16/9/0.16
6.1
PE
582.5
85.8
187
HG-55/U
1/0.813
BC
2.9
16/7/0.127
16/7/0.127
PE
53.52.5
93.6
138
RG-58/U
1/0.813
BC
2.95
16/7/0.127
4.95
PVC
53.52.5
93.5
138
RG-58A/U
19/0.18
TC
2.95
16/7/0.127
4.95
PVC
502
93.5
174
RG-58C/U
19/0.18
TC
2.95
16/7/0.127
4.95
NC.PVC
502
93.5
174
RG-59/U
1/0.643
CCS
3.71
16/7/0.16
6.15
PVC
733
68.9
125
RG-59A/U
1/0.643
CCS
3.71
16/7/0.16
6.15
NC.PVC
733
68.9
125
RG-59B/U
1/0.584
CCS
3.71
16/7/0.16
6.15
NC.PVC
753
68.9
112
RG-62/U
1/0.643
CCS
3.71
16/7/0.16
6.15
PVC
93
44.3
102
RG-62A/U
1/0.643
CCS
3.71
16/7/0.16
6.15
NC.PVC
935
44.3
102
RG-63/U
1/0.643
CCS
7.24
24/8/0.18
10.3
PVC
125
32.8
66
RG-63B/U
1/0.643
CCS
7.24
24/8/0.18
10.3
NC.PVC
1256
32.8
66
RG-71/U
1/0.643
CCS
3.71
16/7/0.16
16/9/0.127
6.4
PE
93
44.3
102
RG-89/U
1/0.643
CCS
7.24
16/12/0.18
16
PVC
125
32.8
66
RG-108/U
7/0.32*2C
TC
1.84
16/6/0.127
6.2
NC.PVC
786.5
74.3
RG-108A/U
7/0.32*2C
TC
2.01
16/6/0.127
5.97
NC.PVC
787
74.3
RG-122/U
27/0.127
TC
2.44
16/6/0.127
4.06
NC.PVC
502
105
195
RG-130/U
7/0.724*2C
BC
12
24/8/0.26
15.9
PVC
955
56
99
RG-133A/U
1/0.645
BC
7.2
24/8/0.18
10.3
NC.PVC
95
53
76
RG-164/U
1/2.65
BC
17.3
24/14/0.26
22.1
NC.PVC
753
67
30
RG-213/U
7/0.752
BC
7.24
24/8/0.18
10.3
NC.PVC
502
100
69
RG-216/U
7/0.404
TC
7.24
24/9/0.16
24/8/0.16
10.8
NC.PVC
753
67
88
RG-217/U
1/2.69
BC
9.4
24/10/0.18
24/8/0.18
13.8
NC.PVC
502
100
50
COAX TYPE
CHARACTERISTIC
OUTSIDE
VELOCITY
ATTEN
ATTEN
IMPEDANCE
DIAMETER
FACTOR
@ 100 MHZ
@ 1000 MHZ
RG5/U
52.5
8.4
0.66
1.0
3.8
RG6A/U
75
8.4
0.66
1.0
3.7
RG9/U
51.0
10.7
0.66
0.66
2.4
RG10A/U
50
12.1
0.66
0.66
2.6
RG11A/U
75
10.3
0.66
0.76
2.6
RG12A/U
75
12.1
0.66
0.76
2.6
RG20A/U
50
30.4
0.66
0.22
1.2
RG22
95
10.7
0.75
1.5
RG23
125
24.0
0.52
2.0
RG24
125
25.5
0.52
2.0
RG34
75
16.0
0.46
1.8
RG58C/U
50
5.0
0.66
1.8
7.6
RG59B/U
75
6.1
0.66
1.2
4.6
RG62A/U
93
6.1
0.84
0.9
2.8
RG63
125
10.3
0.6
2.1
RG79
125
12.1
0.6
2.1
RG108
78
6.0
1.1
3.8
RG111
95
12.1
0.75
2.6
RG114
185
10.3
1.1
3.8
RG119
50
11.8
0.5
1.8
RG120
50
13.3
0.5
1.8
RG122
50
4.1
1.7
5.5
COMMENTS
COAX TYPE
CHARACTERISTIC
OUTSIDE
VELOCITY
ATTEN
ATTEN
COMMENTS
IMPEDANCE
DIAMETER
FACTOR
@ 100 MHZ
@ 1000 MHZ
RG213/U
50
10.3
0.66
0.62
2.6
Polythene dielectric
RG214/U
50
10.8
0.66
0.76
2.9
RG223/U
50
5.5
0.66
1.58
5.4
UR43
50
0.66
1.3
4.46
UR57
75
10.2
0.66
0.63
2.3
Similar to RG11A/U
UR67
50
10.3
0.66
0.66
2.52
Similar to RG213/U
UR74
51
22.1
0.66
0.33
1.4
UR76
51
0.66
1.7
7.3
UR77
75
22.1
0.66
0.33
1.4
UR79
50
21.7
0.96
0.17
0.6
UR90
75
6.1
0.66
1.2
4.1
Similar to RG58C/U
Similar to RG59B/U
Electrical Characteristics:
Maximum frequencies are those as referenced on individual slant sheets of the MIL-C-17 specification. No values are given for unswept constructions
as the specification recommends these cables should not be used above 400 MHz. All figures referenced above are nominal unless otherwise specified.
Attenuation (dB/100ft) @
M17 Number Impedance Capacitance Max Voltage 100 MHz 400 MHz 1 GHz 2.4 GHz 5 GHz 10 GHz Max Frequency
(ohms) (pF/ft) Typ / Max Typ / Max Typ / Max Typ / Max Typ / Max Typ / Max (GHz)
M17/60-RG142 50 +/- 2 29.4 1900 4.0 / 5.5 8.1 / 11.7 13.4 / 19.2 21.3 / 30.4 33.3 / 48.7 - 17.4
M17/76-RG217 50 +/- 2 30.8 7000 1.5 / 1.6 3.5 / 3.7 6.7 / 7.0 - - - 3.0
M17/93-RG178 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0
M17/93-00001 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0
M17/94-RG179 75 +/- 3 19.4 1200 8.0 / 9.2 15.5 / 21.0 26.7 / 30.7 - - - M17/95-RG180 95 +/- 5 17.4 1500 5.7 / 6.6 11.7 / 17.4 19.2 / 23.0 - - - M17/110-RG302 75 +/- 3 19.4 2300 - 7.2 / 8.0 - - - - M17/111-RG303 50 +/- 2 29.4 1900 3.5 / 3.9 7.2 / 8.0 13.5 / 15.0 - - - M17/112-RG304 50 +/- 2 29.4 3000 2.4 / 2.7 5.8 / 6.4 10.0 / 11.1 - - - 8.0
M17/113-RG316 50 +/- 2 29.4 1200 7.6 / 11.0 16.0 / 21.0 26.2 / 38.0 41.2 / 55.4 - - 3.0
M17/127-RG393 50 +/- 2 29.4 2500 2.3 / 2.5 4.4 / 5.0 7.7 / 9.2 12.4 / 14.2 21.3 / 26.8 30.1 / 37.9 11.0
M17/128-RG400 50 +/- 2 29.4 1900 4.3 / 4.5 8.6 / 10.5 14.1 / 18.1 22.6 / 30.2 35.6 / 52.1 61.6 / 78.0 12.4
M17/131-RG403 50 +/- 2 29.4 1000 - 33.3 / 37.0 - - - - 10.0
M17/152-00001 50 +/- 2 29.4 1200 8.1 / 11.5 17.8 / 24.0 29.6 / 40.0 43.1 / 58.3 100.0 /110.0 153.0/170.0 12.4
M17/158-00001 50 +/- 2 29.4 1900 - 8.1 / 9.5 - - - M17/165-00001 50 +/- 2 29.4 7000 - 3.5 / 3.7 - - - M17/169-00001 50 +/- 2 29.4 1000 - 27.2 / 29.0 - - - - M17/170-00001 50 +/- 2 29.4 1900 - 7.7 / 8.6 - - - - M17/172-00001 50 +/- 2 29.4 1200 - 15.5 / 21.0 - - - - M17/174-00001 50 +/- 2 29.4 2500 - 4.4 / 5.0 - - - - M17/175-00001 50 +/- 2 29.4 1900 - 8.6 /10.5 - - - - M17/176-00001 77 +/- 7 19.0 1000 - - - - - - PTFE Tape Wrap Jacketed RG Cables
RG 187 A/U 75 +/- 3 19.4 1200 - 15.5 / 21.0 - - - RG 188 A/U 50 +/- 2 29.4 1200 7.6 / 11.0 16.0 / 21.0 26.2 / 38.0 41.2 / 55.4 - - 3.0
RG 195 A/U 95 +/- 5 17.4 1500 - 11.7 / 17.4 - - - RG 196 A/U 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0
50 Ohm
RG-8
RG-8*
RG-8A
RG-9*
RG-58
RG-58A
RG-58A*
RG-58C
RG-141#
RG-174
RG-223#
9913
72 Ohm
RG-11
RG-11A
RG-59
RG-59*
RG-59B
CONDUCTOR
INSULATION
SHIELD
Cover
JACKET
Material Diameter
7/19
7/19
7/21
7/21
Solid
19/33
7/28
19/33
Solid
7/34
Solid
Solid
0.108
0.108
0.085
0.86
0.32
0.35
0.37
0.35
0.037
0.019
0.035
0.108
FP
FP
PE
PE
PE
PE
PE
PE
TF
PE
PE
FP
0.285
0.285
0.285
0.280
0.116
0.116
0.114
0.116
0.116
0.060
0.116
0.285
97%
*96%
97%
*96%
95%
96%
*96%
96%
#96%
88%
#*97%
100%
PE
PE
NC
NC
PV
PV
PV
NC
FG
PV
NC
PV
0.405
0.480
0.405
0.420
0.193
0.195
0.240
0.195
0.190
0.101
0.212
0.405
Solid
7/26
Solid
Solid
Solid
0.064
0.048
0.023
0.032
0.023
FP
PE
PE
FP
PE
0.285
0.285
0.146
0.143
0.146
95%
97%
95%
*96%
95%
PV
PV
PV
PE
NC
0.405
0.405
0.146
0.315
0.242
17
21
21
17
21
0.4db
0.7db
1.1db
1.0db
1.1db
Catalog
No.
RG/U
No.
Nom.
Imp.
Type
Dielect.
Mat.
Cap.
Jacket
Size (in)
and
Type of
Inner
Cond.
Overall
Diameter
Shield
N/A
Waveguide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Waveguide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.226
in
5.74
mm
N/A
PVC-I
2
BC
0.226
in
5.74
mm
0.0320 BC
0.332
in
8.43
mm
0.0508 BC
0.328
in
8.33
0.0508 S
N/A
Waveguide
N/A
N/A
N/A
N/A
5074
Coax
Cable
50
30.0
pF/ft
98.4
pF/m
5075
Coax
Cable
52.5
28.5
pF/ft
93.5
pF/m
PE
PVC-I
2
BC
5A
5075A
Coax
Cable
50
30.8
pF/ft
101
PE
PVC-II
2S
PE
5B*
5075B
Coax
Cable
pF/m
mm
50
30.8
pF/ft
101
pF/m
2S
0.338
in
8.59
mm
0.0508 S
PVC-II
BCS
0.332
in
8.43
mm
0.0285
CW
PVC-IIA
BCS
0.332
in
8.43
mm
0.0285
CW
BC
0.370
in
9.40
mm
0.0359 BC
0.405
in
10.3
mm
7/21 BC
PE
5076
Coax
Cable
75
22.0
pF/ft
72.2
pF/m
6A*
5076A
Coax
Cable
75
22.0
pF/ft
72.2
pF/m
PE
Air
space
PE
5077
Coax
Cable
95
12.5
pF/ft
41.0
pF/m
5078
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
8A*
5078A
Coax
Cable
52
29.5
pF/ft
PE
PVC-IIA
PVC-I
PE
PVC-I
BC
PE
PVC-IIA
BC
0.405
in
7/21 BC
96.8
pF/m
5079
Coax
Cable
50
30.0
pF/ft
98.4
pF/m
9A
5079A
Coax
Cable
50
30.0
pF/ft
98.4
pF/m
9B*
5079B
Coax
Cable
50
30.0
pF/ft
98.4
pF/m
10
50710
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
10A*
50710A
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
10.3
mm
PE
PE
PVC-II
PVC-II
PE
PVC-IIA
PE
PVC-II
w/armor
PE
PVC-IIA
w/armor
BCS
0.420
in
10.7
mm
7/21 S
2S
0.420
in
10.7
mm
7/21 S
2S
0.420
in
10.7
mm
7/21 S
BC
0.475
in
12.1
mm
7/21 BC
BC
0.475
in
12.1
mm
7/21 BC
11
50711
Coax
Cable
75
22.0
pF/ft
72.2
pF/m
11A*
50711A
Coax
Cable
75
22.0
pF/ft
72.2
pF/m
12
50712
Coax
Cable
75
20.5
pF/ft
67.3
pF/m
12A*
50712A
Coax
Cable
75
20.5
pF/ft
67.3
pF/m
13
50713
Coax
Cable
74
20.5
pF/ft
67.3
pF/m
13A*
50713A
Coax
Cable
74
20.5
pF/ft
67.3
pF/m
PE
PE
BC
0.405
in
10.3
mm
7/26 TC
BC
0.405
in
10.3
mm
7/26 TC
BC
0.475
in
12.1
mm
7/26 TC
BC
0.475
in
12.1
mm
7/26 TC
PVC-I
2
BC
0.420
in
10.7
mm
7/26 TC
PVC-IIA
2
BC
0.420
in
10.7
mm
7/26 TC
PVC-I
PVC-IIA
PE
PVC-II
w/armor
PE
PVC-IIA
w/armor
PE
PE
14
50714
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
14A*
50714A
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
PE
PE
PVC-II
2
BC
0.545
in
13.8
mm
PVC-IIA
2
BC
0.545
in
13.8
mm
0.1020 BC
2
BC
0.545
in
13.8
mm
0.0571
CW
BC
0.630
in
16.0
mm
0.125 BC
tube
0.188 BC
0.188 BC
15
50715
Coax
Cable
76
20.0
pF/ft
65.6
pF/m
16
50716
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
17
50717
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
PE
PVC-II
BC
0.879
in
22.3
mm
17A*
50717A
Coax
Cable
52
29.5
pF/ft
96.8
PE
PVC-IIA
BC
0.870
in
22.1
PE
PE
PVC-I
PVC-I
0.1020 BC
17B
50717B
Coax
Cable
pF/m
mm
52
29.5
pF/ft
96.8
pF/m
2S
0.940
in
23.9
mm
0.188 BC
BC
0.945
in
24.0
mm
0.188 BC
BC
0.945
in
24.0
mm
0.188 BC
BC
1.120
in
28.4
mm
0.250 BC
1.120
in
28.4
mm
0.250 BC
18
50718
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
18A*
50718A
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
19
50719
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
19A*
50719A
Coax
Cable
52
29.5
pF/ft
96.8
pF/m
20
50720
Coax
Cable
52
29.5
pF/ft
PE
PVC-IIA
PE
PVC-IA
w/armor
PE
PVC-IIA
w/armor
PE
PVC-II
PE
PVC-IIA
BC
PE
PVC-II
w/armor
BC
1.195
in
0.250 BC
96.8
pF/m
20A*
50720A
Coax
Cable
52
29.6
pF/ft
97.1
pF/m
21
50721
Coax
Cable
53
29.0
pF/ft
95.1
pF/m
21A*
50721A
Coax
Cable
53
29.0
pF/ft
95.1
pF/m
22
50722
Coax
Cable
95
18.4
pF/ft
60.4
pF/m
22A
50722A
Coax
Cable
95
16.3
pF/ft
53.5
pF/m
30.4
mm
PE
PE
PE
PE
PE
BC
1.178
in
29.92
mm
0.250 BC
2S
0.332
in
8.43
mm
0.0508 N
PVC-IIA
2S
0.332
in
8.43
mm
0.0508 N
PVC-IIA
2
TC
0.420
in
10.7
mm
2 cond.
7/0.0152
BC
PVC-IIA
2
TC
0.420
in
10.7
mm
2 cond.
7/0.0152
BC
PVC-IIA
w/armor
PVC-II
22B*
23
23A*
50722B
50723
50723A
Coax
Cable
Coax
Cable
Coax
Cable
95
125
125
16.3
pF/ft
53.5
pF/m
13.0
pF/ft
42.7
pF/m
13.0
pF/ft
42.7
pF/m
PE
PE
PE
PVC-IIA
PVC-I
PVC-IIA
2
TC
0.420
in
10.7
mm
2 cond.
7/0.0152
BC
2
BC
0.650
x
0.945
in
16.5 x
24.0
mm
2 cond.
7/21 BC
2
BC
0.650
x
0.945
in
16.5 x
24.0
mm
2 cond.
7/21 BC
2 cond.
7/21 BC
2 cond.
24
50724
Coax
Cable
125
13.0
pF/ft
42.7
pF/m
PE
PVC-I
w/armor
2
BC
0.735
x
1.034
in
18.7 x
26.3
mm
24A*
507-
Coax
125
13.0
pF/ft
PE
PVC-IIA
0.735
x
24A
Cable
25*
50725
Coax
Cable
48
50.0
pF/ft
164
pF/m
25A*
50725A
Coax
Cable
48
50.0
pF/ft
164
pF/m
26*
50726
Coax
Cable
48
50.0
pF/ft
164
pF/m
48
50.0
pF/ft
164
pF/m
26A*
50726A
Coax
Cable
42.7
pF/m
w/armor
BC
1.034
in
18.7 x
26.3
mm
7/21 BC
Rubber
RubberIV
2
TC
0.505
in
12.8
mm
19/0.0117
TC
Rubber
RubberIV
2
TC
0.505
in
12.8
mm
19/0.0117
TC
Rubber
RubberIV
w/armor
TC
0.525
in
13.3
mm
19/0.0117
TC
Rubber
RubberIV
w/armor
TC
0.505
in
12.8
mm
19/0.0117
TC
50727
27
Catal
og
No.
RG/
U
No.
27A*
28
Coax
Cable
Nom.
Imp.
Type
507-27A
507-28
48
Coax
Cable
Coax
Cable
50.0
pF/ft
164
pF/m
Cap
.
Rubber
Dielect
. Mat.
48
50.0
pF/ft
164
pF/m
50
50.0
pF/ft
164
pF/m
PVC-II
Jacket
Rubb
er
Rubb
er
0.675
in
17.1
mm
TC
RubberIV
w/armor
RubberIV
Siz
e
(in)
and
Typ
e of
Inn
er
Co
nd.
Overa
ll
Diam
eter
Shield
19/0.0185
TC
TC
0.6
70
in
17.
0
mm
19/0.0
185
TC
TC
GS
0.8
05
in
20.
4
mm
19/0.0
185
TC
28A
28B*
29
30
507-28A
507-28B
507-29
507-30
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
50
50.0
pF/ft
164
pF/m
48
50.0
pF/ft
164
pF/m
53.5
28.5
pF/ft
93.5
pF/m
50
27.0
pF/ft
88.6
pF/m
Rubb
er
Rubb
er
PE
Copo
.
RubberIV
w/armor
RubberIV
PE-III
PVC-I
TC
0.8
05
in
20.
4
mm
19/0.0
185
TC
TC
GS
0.7
50
ma
x.
in
19.
1
ma
x.
mm
19/0.0
185
TC
TC
0.1
84
in
4.6
7
mm
0.032
0 BC
BC
0.2
50
in
6.3
5
7/26
BC
mm
31
32
33
34
507-31
507-32
507-33
507-34
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
51
31.0
pF/ft
102
pF/m
51
29.0
pF/ft
95.1
pF/m
51
30.0
pF/ft
98.4
pF/m
71
21.5
pF/ft
70.5
pF/m
Copo
.
Copo
.
PE
PE
PVC-I
PVC-I
w/armor
Lead
PVC-I
BC
0.4
05
in
10.
3
mm
7/21
BC
BC
0.4
65
in
11.
8
mm
7/21
BC
Non
e
0.4
70
in
11.
9
mm
0.101
9 BC
BC
0.6
25
in
15.
9
mm
7/21
BC
34A
34B*
35
507-34A
507-34B
507-35
Coax
Cable
Coax
Cable
Coax
Cable
71
75
21.5
pF/ft
70.5
pF/m
21.5
pF/ft
70.5
pF/m
PE
PE
PVC-IIA
PVC-IIA
BC
0.6
30
in
16.
0
mm
7/0.02
49 BC
BC
0.6
30
in
16.
0
mm
7/.024
9 BC
BC
0.9
45
in
24.
0
mm
0.114
4 BC
0.104
5 BC
75
22.0
pF/ft
72.2
pF/m
22.0
pF/ft
72.2
pF/m
PE
PVC-IIA
w/armor
BC
0.9
45
in
24.
0
mm
22.0
pF/ft
72.2
PE
PVC-IIA
w/armor
BC
0.9
45
ma
35A
507-35A
Coax
Cable
75
35B*
507-35B
Coax
Cable
75
PE
PVC-II
w/armor
0.104
5 BC
pF/m
36
37
507-36
507-37
Coax
Cable
Coax
Cable
x.
in
24.
0
ma
x.
mm
BC
1.1
80
in
29.
97
mm
0.162
0 BC
TC
0.2
10
in
5.3
3
mm
0.032
0 TC
0.045
3 TC
0.025
3
69
22.0
pF/ft
72.2
pF/m
52.5
38.0
pF/ft
125
pF/m
Rubb
er-C
PE-III
2
TC
0.3
12
in
7.9
2
mm
Rubb
PE-III
0.3
12
38
507-38
Coax
Cable
52.5
38.0
pF/ft
125
pF/m
39
507-39
Coax
72.5
28.6
pF/ft
PE
Rubb
er-C
PVC-I
PE-III
Cable
40
41
42
43
507-40
507-41
507-42
507-43
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
93.8
pF/m
72.5
28.0
pF/ft
91.9
pF/m
67.5
27.6
pF/ft
90.6
pF/m
78.6
20.0
pF/ft
65.6
pF/m
95
17.6
pF/ft
57.7
pF/m
er-C
Rubb
er-C
Rubb
er-C
PE
Rubb
er-B
TC
RubberIV
RubberIV
PVC-II
PVC-I
in
7.9
2
mm
TCW
2
TC
0.4
20
in
10.
7
mm
0.025
3
TCW
TC
0.4
25
in
10.
8
mm
16/30
TC
2S
0.3
42
in
8.6
9
mm
0.028
5N
BC
0.6
17
in
15.
7
2
cond.
7/21
BC
mm
507-44
Stub
support
ed
coaxial
N/A
N/A
N/A
N/A
N/A
N/A
N/A
507-45
Stub
support
ed
coaxial
N/A
N/A
N/A
N/A
N/A
N/A
N/A
507-46
Stub
support
ed
coaxial
N/A
N/A
N/A
N/A
N/A
N/A
N/A
47
507-47
Stub
support
ed
coaxial
N/A
N/A
N/A
N/A
N/A
N/A
N/A
48
507-48
Waveg
uide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
49
507-49
Waveg
uide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
44
45
46
50
507-50
Waveg
uide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
51
507-51
Waveg
uide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
52
507-52
Waveg
uide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
53
507-53
Waveg
uide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
58
27.0
pF/ft
88.6
pF/m
BC
0.2
75
in
7.0
mm
7/26
BC
58
26.5
pF/ft
86.9
pF/m
TC
0.2
50
in
6.4
mm
7/.015
2 BC
53.5
28.5
pF/ft
93.5
pF/m
2
TC
0.2
00
in
5.1
mm
0.320
BC
54
54A
55
507-54
507-54A
507-55
Coax
Cable
Coax
Cable
Coax
Cable
PE
PE
PE
PVC-I
PE-III
PE-III
55A
55B*
56
57
507-55A
507-55B
507-56
507-57
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
50
28.5
pF/ft
93.5
pF/m
53
28.5
pF/ft
93.5
pF/m
48
50.0
pF/ft
164
pF/m
95
17.0
pF/ft
55.8
pF/m
PE
PE
Rubb
er-C
PE
PVC-IIA
PE-III
PVC-I
PVC-I
2S
0.2
00
in
5.1
mm
0.035
S
2
TC
0.2
00
ma
x.
in
5.0
8
ma
x.
mm
0.032
S
2
BC
0.5
35
in
13.
6
mm
19/.01
17 BC
TC
0.6
25
in
15.
9
mm
2
cond.
7/21
BC
57A*
58
58A
58B
58C*
507-57A
507-58
507-58A
Coax
Cable
Coax
Cable
Coax
Cable
507-58B
Coax
Cable
507-
Coax
95
17.0
pF/ft
55.8
pF/m
53.5
28.5
pF/ft
93.5
pF/m
50
32.2
pF/ft
106
pF/m
53.5
28.5
pF/ft
93.5
pF/m
50
32.2
pF/ft
PE
PE
PE
PVC-IIA
PVC-I
PVC-I
TC
0.6
25
in
15.
9
mm
2
cond.
7/21
BC
TC
0.1
95
in
4.9
5
mm
0.032
0 BC
TC
0.1
95
in
4.9
5
mm
19/33
TC
0.1
95
in
4.9
5
mm
0.032
0 BC
0.1
95
19/33
PE
PVC-IIA
TC
PE
PVC-IIA
TC
58C
59
59A
59B*
60
507-59
507-59A
507-59B
507-60
Cable
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
106
pF/m
73
22.0
pF/ft
72.2
pF/m
75
22.0
pF/ft
72.2
pF/m
75
22.0
pF/ft
72.2
pF/m
50
39.0
pF/ft
128
pF/m
in
4.9
5
mm
PE
PE
PE
Rubb
er
PVC-II
PVC-IIA
PVC-IIA
RubberIV
TC
BC
0.2
42
in
6.1
5
mm
0.022
6 CW
BC
0.2
42
in
6.1
5
mm
0.022
6 CW
BC
0.2
42
in
6.1
5
mm
0.022
6 CW
BC
0.4
25
in
10.
8
0.050
8
strand
ed BC
mm
61
507-61
Catal
og
No.
RG
/U
No.
62
62
A*
Special
500
ohm
line
No
m.
Im
p.
Ty
pe
50762
50762A
Coax
Cable
Coax
Cable
N/A
Diele
ct.
Mat.
Ca
p.
N/A
Jac
ket
93
14.
5
pF/
ft
47.
6
pF/
m
Air
spac
e PE
93
14.
5
pF/
ft
47.
6
Air
spac
e PE
N/A
PVCIIA
Size
(in)
and
Typ
e of
Inne
r
Con
d.
Overa
ll
Diam
eter
Shie
ld
PVCIIA
N/A
BC
0.2
42
in
6.1
5
mm
0.0253
CW
BC
0.2
42
in
6.1
5
0.0253
CW
N/A
N/A
N/A
pF/
m
62
B
63
63
A
50762B
50763
50763A
Coax
Cable
Coax
Cable
Coax
Cable
93
14.
5
pF/
ft
47.
6
pF/
m
12
5
11.
0
pF/
ft
36.
1
pF/
m
12
5
11.
0
pF/
ft
36.
1
pF/
m
mm
Air
spac
e PE
Air
spac
e PE
Air
spac
e PE
PVCIIA
PVCIIA
PVCIIA
BC
0.2
42
in
6.1
5
mm
7/32
CW
BC
0.4
05
in
10.
3
mm
0.0253
CW
BC
0.4
05
in
10.
3
mm
0.0253
BC
63
B*
64*
64
A*
65
50763B
50764
50764A
50765
12
5
11.
0
pF/
ft
36.
1
pF/
m
48
50.
0
pF/
ft
16
4
pF/
m
Coax
Cable
48
50.
0
pF/
ft
16
4
pF/
m
Coax
Cable
95
0
Coax
Cable
Coax
Cable
44.
0
pF/
ft
14
Air
spac
e PE
Rubb
er-IV
Rubb
er-IV
PE
PVCIIA
Rubb
er-IV
Rubb
er-IV
PVCI
BC
0.4
05
in
10.
3
mm
0.0253
CW
2
TC
0.4
95
in
12.
6
mm
19/0.0
117
TC
2
TC
0.4
75
in
12.
1
mm
19/0.0
117
TC
BC
0.4
05
in
10.
3
0.0080
Forme
xF
4
pF/
m
mm
65
A*
50765A
Coax
Cable
95
0
44.
0
pF/
ft
14
4
pF/
m
66
50766
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
67
50767
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
68
50768
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
69
50769
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
70
50770
Not
assigne
d
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
PE
PVCIIA
BC
0.4
05
in
10.
3
mm
0.0080
Forme
xF
71
71
A
71
B*
50771
50771A
50771B
Coax
Cable
Coax
Cable
Coax
Cable
93
13.
5
pF/
ft
44.
3
pF/
m
93
13.
5
pF/
ft
44.
3
pF/
m
93
14.
5
ma
x.
pF/
ft
47.
6
ma
x.
pF/
m
Air
spac
e PE
Air
spac
e PE
Air
spac
e PE
PVCI
PE-III
PEIIIA
2
TC
0.2
45
in
6.2
2
mm
0.0253
CW
2
TC
0.2
45
in
6.2
2
mm
0.0253
CW
2
TC
0.2
50
ma
x.
in
6.3
5
ma
x.
mm
0.0253
CW
72
73
74
74
A*
50772
50773
50774
50774A
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
15
0
7.8
pF/
ft
26
pF/
m
25
61.
8
pF/
ft
20
3
pF/
m
52
29.
6
pF/
ft
97.
1
pF/
m
52
29.
6
pF/
ft
97.
1
pF/
Air
spac
e PE
PE
PE
PE
PVCI
None
PVCII
w/ar
mor
PVCIIA
w/ar
mor
BC
0.6
30
in
16.
0
mm
0.0253
CW
2
BC
0.1
75
in
4.4
5
mm
0.0320
BC
2
BC
0.6
03
in
15.
3
mm
0.1020
BC
2
BC
0.6
03
in
15.
3
mm
0.1020
BC
75
50775
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
76
50776
Stub
support
ed
coaxial
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
48
50.
0
pF/
ft
16
4
pF/
m
2
TC
0.4
50
in
11.
4
mm
19/0.0
117
TC
Rubb
er
PVCIIA
TC
0.4
20
in
10.
7
mm
19/0.0
117
TC
Air
spac
PVCI
BC
0.4
75
0.0253
77
A
50777A
Coax
Cable
78
A
50778A
Coax
Cable
48
50.
0
pF/
ft
16
4
pF/
m
79
507-
Coax
12
5
11.
0
Rubb
er
PVCIIA
79
79
A
79
B*
50779A
50779B
Cable
Coax
Cable
Coax
Cable
pF/
ft
36.
1
pF/
m
12
5
11.
0
ma
x.
pF/
ft
36.
1
ma
x.
pF/
m
12
5
11.
0
ma
x.
pF/
ft
36.
1
ma
x.
pF/
m
e PE
w/ar
mor
Air
spac
e PE
PVCI
w/ar
mor
Air
spac
e PE
PVCIIA
w/ar
mor
in
12.
1
mm
CW
BC
0.4
75
in
12.
1
mm
0.0253
CW
BC
0.4
75
in
12.
1
mm
0.0253
CW
80
81*
82*
83
50780
50781
50782
50783
Bead
support
ed
coaxial
Coax
Cable
Coax
Cable
Coax
Cable
N/
A
N/
A
50
37.
0
pF/
ft
12
1
pF/
m
50
36.
0
pF/
ft
11
8
pF/
m
35
44.
0
pF/
ft
14
4
pF/
N/A
Mag.
Ox.
Mag.
Ox.
PE
N/A
None
None
PVCI
N/A
N/A
N/A
BC
Tub
e
0.3
25
in
8.2
6
mm
0.0625
BC
BC
Tub
e
0.7
50
in
19.
1
mm
0.1250
BC
BC
0.4
05
in
10.
3
mm
0.1020
BC
84
A*
85
A*
86*
50784A
50785A
50786
Coax
Cable
Coax
Cable
Coax
Cable
75
21.
5
pF/
ft
70.
5
pF/
m
75
21.
5
pF/
ft
70.
5
pF/
m
20
0
7.8
pF/
ft
26
pF/
m
PE
PVCIIA
w/lea
d
PE
PVCIIA
w/lea
d
PE
None
BC
1.0
00
in
25.
40
mm
0.1045
BC
BC
1.5
65
in
39.
75
mm
0.1045
BC
Non
e
0.6
50
x
0.3
00
in
16.
5x
7.6
2
mm
2
cond.
7/21
BC
87
87
A*
50787
50787A
Coax
Cable
Coax
Cable
50
29.
5
pF/
ft
96.
8
pF/
m
50
29.
5
pF/
ft
96.
8
pF/
m
Rubb
er
PVCI
4
TC
0.5
15
ma
x.
in
13.
1
ma
x.
mm
Rubb
PVC-
0.5
15
88*
50788
Coax
Cable
48
50.
0
pF/
ft
16
4
pF/
m
88
507-
Coax
48
50.
0
TFE
TFE
FG-V
FG-V
BC
&S
0.4
25
in
10.
8
mm
7/20 S
2S
0.4
25
in
10.
8
mm
7/20 S
19/0.0
117
TC
19/0.0
117
A*
88
B
89
90
88A
50788B
50789
50790
Cable
Coax
Cable
Coax
Cable
Coax
Cable
pF/
ft
16
4
pF/
m
48
50.
0
pF/
ft
16
4
pF/
m
12
5
10.
0
pF/
ft
32.
8
pF/
m
50
30.
8
pF/
ft
10
er
Rubb
er
Air
spac
e PE
PE
IIA
TC
ma
x.
in
13.
1
ma
x.
mm
TC
4
TC
0.5
65
in
14.
4
mm
19/0.0
117
TC
PVCI
BC
0.6
32
in
16.
1
mm
0.0253
CW
PVCIIA
2
TC
1
GS
0.4
25
in
10.
8
7/24 S
Rubb
er-IV
1
pF/
m
mm
91
50791
Waveg
uide
N/
A
N/
A
N/A
92
50792
Coax
Cable
46
N/
A
SS
TFE
50
29.
0
pF/
ft
95.
1
pF/
m
50
29.
0
pF/
ft
95.
1
pF/
m
93
94*
50793
50794
Coax
Cable
Coax
Cable
TFE
tape
TFE
tape
N/A
N/A
N/A
N/A
None
BC
Tub
e
N/A
0.375
BC
BC
0.7
10
in
18.
0
mm
19/18
BC
2
BC
0.4
45
in
11.
3
mm
19/23
S
FG-V
FG-V
94
A
50794A
Coax
Cable
50
29.
0
pF/
ft
95.
1
pF/
m
95
50795
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
96
50796
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
Catal
og
No.
RG/
U
No.
97
FG-V
Nom.
Imp.
Type
507-97
TFE
tape
Wavegu
ide
Ca
p.
N/
A
2
BC
0.5
00
in
12.
7
mm
19/22
S
Dielec
t. Mat.
N/A
N/A
Overa
ll
Diam
eter
Shiel
d
Jacket
N/A
Siz
e
(in)
and
Typ
e of
Inn
er
Con
d.
N/A
N/A
N/A
98
507-98
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
99
507-99
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
35
44.0
pF/ft
144
pF/m
BC
0.2
42
in
6.1
5
mm
19/0.0
147
BC
TC
0.5
88
in
14.
9
mm
0.0641
BC
TC
1.0
88
in
27.
64
mm
2
cond.
0.0808
BC
100
101
102
507-100
507-101
507-102
Coax
Cable
Coax
Cable
Coax
Cable
75
14
0
N/A
N/A
PE
Rubbe
r
Rubbe
r
PVC-I
103
507-103
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
104
507-104
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
105
507-105
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
106
507-106
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
107
507-107
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
78
24.5
pF/ft
80.4
pF/m
TC
0.2
35
in
5.9
7
mm
2
cond.
7/28
TC
108
507-108
Coax
Cable
PE
XL
polyolefi
n
PE
XL
polyolefi
n
TC
0.2
35
in
5.9
7
mm
108A*
507108A
Coax
Cable
78
24.5
pF/ft
80.4
pF/m
109
507-109
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
110
507-110
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
2
TC
0.4
90
in
12.
4
mm
2
cond.
7/0.01
52 BC
2
TC
0.4
90
in
12.
4
mm
2
cond.
7/0.01
52 BC
111
111A*
507-111
507111A
Coax
Cable
Coax
Cable
95
95
18.4
pF/ft
60.4
pF/m
18.4
pF/ft
60.4
pF/m
PE
PE
PVC-II
w/armor
PVC-IIA
w/armor
2
cond.
7/28
TC
112
507-112
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
113
507-113
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
18
5
6.8
pF/ft
22
pF/m
BC
0.4
05
in
10.
3
mm
0.0070
CW
BC
0.4
05
in
10.
3
mm
0.0070
CW
2S
0.4
15
in
10.
5
7/21 S
114
114A*
115*
507-114
507114A
507-115
Coax
Cable
Coax
Cable
Coax
Cable
18
5
6.8
pF/ft
22
pF/m
50
32.0
pF/ft
105
pF/m
Air
space
PE
Air
space
PE
TFE
tape
PVC-IIA
PVC-IIA
FG-V
mm
115A*
116*
117*
117A*
507115A
507-116
507-117
507117A
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
50
50
32.0
pF/ft
105
pF/m
29.5
pF/ft
96.8
pF/m
50
29.5
pF/ft
96.8
pF/m
50
29.5
pF/ft
96.8
pF/m
TFE
tape
TFE
TFE
TFE
FG-V
FG-V
w/armor
FG-V
FG-V
2S
0.4
15
in
10.
5
mm
7/21 S
2S
0.4
75
in
12.
1
mm
7/20 S
BC
0.7
30
in
18.
5
mm
0.188
BC
BC
0.7
30
in
18.
5
0.188
BC
mm
118*
118A*
119*
120*
507-118
507118A
507-119
507-120
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
50
50
29.0
pF/ft
95.1
pF/m
29.0
pF/ft
95.1
pF/m
50
29.3
pF/ft
96.1
pF/m
50
29.3
pF/ft
96.1
pF/m
TFE
TFE
TFE
TFE
FG-V
w/armor
FG-V
w/armor
FG-V
FG-V
w/armor
BC
0.7
80
in
19.
8
mm
0.188
BC
BC
0.7
80
in
19.
8
mm
0.188
BC
2
BC
0.4
65
in
11.
8
mm
0.102
BC
2
BC
0.5
23
in
13.
3
0.102
BC
mm
121
507-121
Wavegu
ide
122*
507-122
Coax
Cable
123
507-123
Not
assigne
d
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
27/36
TC
50
30.8
pF/ft
101
pF/m
PE
PVC-IIA
TC
0.1
60
in
4.0
6
mm
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
TFE
tape
FG-V
TC
0.2
40
in
6.1
0
mm
0.0253
TCW
Air
space
PVC-IIA
BC
0.6
00
in
124
507-124
Coax
Cable
73
20.3
pF/ft
66.6
pF/m
125
507-125
Coax
Cable
15
0
7.8
pF/ft
26
0.0159
CW
126*
507-126
Coax
Cable
pF/m
50
29.0
pF/ft
95.1
pF/m
PE
TFE
15.
2
mm
FG-V
HR
0.2
80
in
7.1
1
mm
7/24
HR
0.644
BC
128
507-128
Coax
Cable
50
N/A
SS
TFE
None
BC
Tub
e
1.6
25
in
41.
28
mm
129
507-129
Flexible
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
95
17.0
pF/ft
55.8
pF/m
TC
0.6
25
in
15.
9
2
cond.
7/21
BC
130*
507-130
Coax
Cable
PE
PVC-I
mm
131*
507-131
Coax
Cable
132
507-132
Wavegu
ide
133
133A*
507-133
507133A
Coax
Cable
Coax
Cable
95
17.0
pF/ft
55.8
pF/m
N/
A
N/A
95
16.2
pF/ft
53.1
pF/m
95
16.2
pF/ft
53.1
pF/m
PE
PVC-I
w/armor
TC
0.7
10
in
18.
0
mm
N/A
N/A
N/A
N/A
N/A
BC
0.4
05
in
10.
3
mm
0.0285
BC
BC
0.4
05
in
10.
3
mm
0.0253
BC
PE
PE
PVC-I
PVC-IIA
2
cond.
7/21
BC
Bras
s
0.4
50
in
11.
4
mm
0.0126
BC
134
507-134
Coax
Cable
18
5
6.5
pF/ft
21
pF/m
135
507-135
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
136
507-136
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
137
507-137
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
138
507-138
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
139
507-139
Wavegu
ide
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
140*
507-140
Coax
75
21.0
pF/ft
TFE
FG-V
0.2
33
0.0250
SS
TFE
None
Cable
Catal
og
No.
RG
/U
No.
141
141
A*
No
m.
Imp
.
Ty
pe
507141
507141
A
Coax
Cable
Coax
Cable
68.9
pF/m
Diele
ct.
Mat.
Ca
p.
50
29.
4
pF/
ft
96.
5
pF/
m
50
29.
4
pF/
ft
96.
5
in
5.9
2
mm
Jack
et
TFE
TFE
Overa
ll
Diame
ter
Shie
ld
FG-V
FG-V
Siz
e
(in)
and
Typ
e of
Inn
er
Con
d.
0.1
90
in
4.8
3
mm
0.03
59
SCC
S
0.1
90
in
4.8
3
mm
0.03
90
SCC
S
SCCS
pF/
m
142
142
A*
142
B*
507142
507142
A
507142
B
Coax
Cable
Coax
Cable
Coax
Cable
50
29.
3
pF/
ft
96.
1
pF/
m
50
29.
3
pF/
ft
96.
1
pF/
m
50
29.
3
pF/
ft
96.
1
pF/
m
TFE
TFE
TFE
FEPIX
FEPIX
FEPIX
2S
0.1
95
in
4.9
5
mm
0.03
70
SCC
S
2S
0.1
95
in
4.9
5
mm
0.03
70
SCC
S
2S
0.1
95
in
4.9
5
mm
0.03
70
SCC
S
143
143
A*
144
*
507143
507143
A
507144
Coax
Cable
Coax
Cable
Coax
Cable
50
29.
4
pF/
ft
96.
5
pF/
m
50
29.
4
pF/
ft
96.
5
pF/
m
75
22.
0
pF/
ft
72.
2
pF/
m
TFE
TFE
TFE
FG-V
FG-V
FG-V
2S
0.3
25
in
8.2
6
mm
0.05
70
SCC
S
2S
0.3
25
in
8.2
6
mm
0.05
90
SCC
S
0.4
10
in
10.
4
mm
7/25
SCC
S
145
146
507145
507146
Coax
Cable
Coax
Cable
75
14.
6
pF/
ft
47.
9
pF/
m
19
0
6.0
pF/
ft
20
pF/
m
29.
5
pF/
ft
96.
8
pF/
m
147
507147
Coax
Cable
52
148
507148
Coax
Cable
52
29.
5
pF/
ft
Air
space
PE
Lead
-tar
Air
space
TFE
FG-V
PE
PVCI
w/ar
mor
PE
PVCI
w/ar
mor
BC
Tube
N/A
2
con
d.
0.07
20
BC
BC
0.3
75
in
9.5
3
mm
0.00
70
CW
BC
1.9
38
in
49.
23
mm
0.25
0
BC
BC
0.8
00
in
20.
7/21
BC
96.
8
pF/
m
149
*
150
*
151
*
507149
507150
507151
Coax
Cable
Coax
Cable
Coax
Cable
75
20.
5
pF/
ft
67.
3
pF/
m
75
20.
5
pF/
ft
67.
3
pF/
m
50
N/
A
3
mm
PE
PE
N/A
PVCIIA
PVCIIA
w/ar
mor
None
BC
0.4
05
in
10.
3
mm
7/26
TC
BC
0.4
75
in
12.
1
mm
7/26
TC
BC
Tube
0.3
75
in
9.5
3
mm
0.12
5
BC
tube
152
*
153
*
154
155
507152
507153
507154
507155
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
50
50
50
50
N/
A
N/
A
N/
A
N/
A
N/A
N/A
N/A
N/A
None
None
None
None
BC
Tube
6.1
25
in
156
mm
2.60
BC
tube
BC
Tube
1.6
25
in
41.
28
mm
0.66
4
BC
tube
BC
Tube
3.1
25
in
79.
38
mm
1.31
5
BC
tube
BC
Tube
0.8
75
in
22.
2
mm
0.34
1
BC
tube
156
*
157
*
158
*
507156
507157
507158
Coax
Cable
Coax
Cable
Coax
Cable
50
32.
8
pF/
ft
10
8
pF/
m
50
38.
0
pF/
ft
12
5
pF/
m
25
78.
0
pF/
ft
25
6
pF/
m
PE &
conduc
tive PE
PE &
conduc
tive PE
PE &
conduc
tive PE
PVCIIA
PVCIIA
PVCIIA
TC,
GS,
TC
0.5
40
in
13.
7
mm
7/21
TC
TC,
GS,
TC
0.7
25
in
18.
4
mm
19/2
4
TC
TC,
GS,
TC
0.7
25
in
18.
4
mm
37/2
1
TC
159
160
160
A
507159
507160
507160
A
Coax
Cable
Coax
Cable
Coax
Cable
50
29.
0
pF/
ft
95.
1
pF/
m
12
5
12.
0
pF/
ft
39.
4
pF/
m
12
5
12.
0
pF/
ft
39.
4
pF/
m
TFE
tape
PE
PE
FG-V
PVCI
PVCI
BC
BC
0.1
95
in
5.0
mm
0.03
20 S
1.0
55
in
26.
80
mm
2
con
d.
19/2
7
TC
2
con
d.
19/2
7
BC
1.0
55
in
26.
80
mm
2
con
d.
19/2
7
TC
2
con
d.
19/2
7
BC
161
507161
Coax
Cable
70
20.
9
pF/
ft
68.
6
pF/
m
TFE
nylon
0.0
82
in
2.1
mm
7/38
SCB
3.0
65
in
77.
85
mm
0.15
6
BC
tube
162
507162
Coax
Cable
17
5
N/
A
SS
TFE
None
BC
Tube
163
507163
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
75
22.
0
pF/
ft
72.
BC
0.8
70
in
22.
1
0.10
45
BC
164
*
507164
Coax
Cable
PE
PVCIIA
2
pF/
m
165
*
507165
Coax
Cable
mm
50
29.
3
pF/
ft
96.
1
pF/
m
TFE
FG-V
w/ar
mor
0.4
70
in
11.
9
mm
TFE
FG-V
0.4
10
in
10.
4
mm
7/20
S
7/20
S
166
*
507166
Coax
Cable
50
29.
3
pF/
ft
96.
1
pF/
m
167
507167
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
168
507168
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
169
507169
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
170
507170
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
171
507171
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
172
507172
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
173
507173
Waveg
uide
N/
A
N/
A
N/A
N/A
N/A
N/A
N/A
50
32.
2
pF/
ft
10
6
pF/
m
TC
0.1
10
in
2.7
9
mm
7/34
CW
174
*
507174
Coax
Cable
PE
PVCIIA
174
A*
175
507174
A
Coax
Cable
50
30.
8
pF/
ft
10
1
pF/
m
507175
Bead
support
ed
coaxial
line
N/
A
N/
A
49.
0
pF/
ft
16
1
pF/
m
176
*
507176
Coax
Cable
22
40
177
*
507177
Coax
Cable
50
32.
2
pF/
ft
PE
PVCIIA
N/A
N/A
PE
PVCI
PE
PVCIIA
TC
0.1
00
in
2.5
4
mm
7/34
CW
N/A
N/A
N/A
BC
0.4
05
in
10.
3
mm
0.13
5
BC
helix
2S
0.8
95
in
22.
0.19
5
BC
10
6
pF/
m
178
507178
Coax
Cable
7
mm
0.0
79
ma
x.
in
2.0
1
ma
x.
mm
7/38
SC
W
7/38
SC
W
7/38
SC
50
32.
0
pF/
ft
10
5
pF/
m
TFE
FEPIX
0.0
75
ma
x.
in
1.9
1
ma
x.
mm
TFE
FEPIX
0.0
75
178
A*
507178
A
Coax
Cable
50
32.
0
pF/
ft
10
5
pF/
m
178
B*
507178
Coax
Cable
50
32.
0
TFE
FEPIX
179
179
A*
507179
507179
A
pF/
ft
10
5
pF/
m
Coax
Cable
Coax
Cable
75
23.
0
pF/
ft
75.
5
pF/
m
75
23.
0
pF/
ft
75.
5
pF/
m
ma
x.
in
1.9
1
ma
x.
mm
TFE
TFE
FEPIX
FEPIX
0.1
00
ma
x.
in
2.5
4
ma
x.
mm
7/38
SCC
S
0.1
05
ma
x.
in
2.6
7
ma
x.
mm
7/38
SCC
S
179
B*
180
507179
B
507180
Coax
Cable
Coax
Cable
75
95
23.
0
pF/
ft
75.
5
pF/
m
15.
4
pF/
ft
50.
5
pF/
m
TFE
TFE
FEPIX
FEPIX
0.1
05
ma
x.
in
2.6
7
ma
x.
mm
7/38
SCC
S
0.1
41
ma
x.
in
3.5
8
ma
x.
mm
7/38
SCC
S
Catal
og
No.
RG/
U
No.
180A*
180B*
Nom.
Imp.
Type
507180A
507180B
Coax
Cable
Coax
Cable
Ca
p.
95
95
Dielect
. Mat.
15.4
pF/ft
50.5
pF/m
15.4
pF/ft
50.5
pF/m
Jacket
TFE
TFE
Overa
ll
Diam
eter
Shield
FEP-IX
FEP-IX
Siz
e
(in)
and
Typ
e of
Inn
er
Co
nd.
0.1
45
ma
x.
in
3.6
8
ma
x.
mm
0.1
45
ma
x.
in
3.6
8
ma
x.
7/38
SCCS
7/38
SCCS
mm
181*
182
183
184
507181
507182
Coax
Cable
Coax
Cable
507183
Coax
Cable
507-
Waveg
125
125
each
12.0
pF/ft
39.4
pF/m
12.0
each
pF/ft
39.4
each
pF/m
PE
PE
PVC-IIA
PVC-IIA
0.6
40
in
16.
3
mm
2
cond.
7/26
BC
2 BC
1.0
55
in
26.
8
mm
2
cond.
19/0.0
142
BC 2
cond.
19/0.0
066
TC
0.0251
BC
N/A
BC
50
23.0
pF/ft
75.5
pF/m
PS
helix
None
AL
Tube
0.7
50
in
19.
1
mm
N/A
N/A
N/A
N/A
N/A
N/A
184
185
186
187
507185
507186
507187
uide
Coax
Cable
Coax
Cable
Coax
Cable
2000
1000
75
N/A
N/A
19.5
pF/ft
64.0
pF/m
Air
spac
e PE
SS
PE
TFE
PVC-IIA
PVC-IIA
TFE
Magn
et
wire
0.2
82
in
7.1
6
mm
0.0031
RIM
helix
Magn
et
wire
0.4
05
in
10.
3
mm
0.0080
TFE
Magne
t wire
helix
0.1
10
ma
x.
in
2.7
9
ma
x.
mm
7/38
SCCS
187A*
188*
188A*
507187A
507188
507188A
Coax
Cable
Coax
Cable
Coax
Cable
75
50
50
19.5
pF/ft
64.0
pF/m
29.0
pF/ft
95.1
pF/m
29.0
pF/ft
95.1
pF/m
TFE
TFE
TFE
TFE
TFE
TFE
0.1
10
ma
x.
in
2.7
9
ma
x.
mm
7/38
SCCS
0.1
10
ma
x.
in
2.7
9
ma
x.
mm
7/0.00
67
SCCS
0.1
10
ma
x.
in
2.7
9
ma
x.
7/0.00
67
SCCS
mm
189
190*
191*
192
507189
507190
507191
507192
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
50
50
23.0
pF/ft
75.5
pF/m
50.0
pF/ft
164
pF/m
PS
helix
Rubb
er
25
85.0
pF/ft
279
pF/m
Rubb
er
12.5
175.0
pF/ft
574.1
pF/m
Butyl
rubb
er
2S
0.8
75
in
22.
2
mm
0.251
BC
TC,
GS,
TC
0.7
00
in
17.
8
mm
19/0.0
117
TC
Neoprene
VIII
TC,
GS,
TC
1.4
60
in
37.
1
mm
TC
braid
0.485
Rubber
TC,
GS,
GS
2.1
65
in
55.
0
PE-IIIA
Neoprene
VIII
TC
braid
GS
tube
mm
193
194
195*
507193
507194
507195
Coax
Cable
Coax
Cable
Coax
Cable
12.5
12.5
95
159.0
pF/ft
521.7
pF/m
159.0
pF/ft
521.7
pF/m
15.0
pF/ft
49.2
pF/m
Silico
ne
rubb
er
Silico
ne
rubb
er
TFE
Rubber
Rubber
w/AL
armour
TFE
TC,
GS,
GS
2.1
65
in
55.
0
mm
TC
braid
GW
tube
TC,
GS,
GS
2.0
1
ma
x.
in
51.
1
ma
x.
mm
TC
braid
GW
tube
0.1
55
ma
x.
in
3.9
4
ma
x.
7/38
SCCS
mm
195A*
196*
196A*
507195A
507196
507196A
Coax
Cable
Coax
Cable
Coax
Cable
95
15.0
pF/ft
49.2
pF/m
50
28.5
pF/ft
93.5
pF/m
50
28.5
pF/ft
93.5
pF/m
TFE
TFE
TFE
TFE
TFE
TFE
0.1
55
ma
x.
in
3.9
4
ma
x.
mm
7/38
SCCS
0.0
80
ma
x.
in
2.0
3
ma
x.
mm
7/38
SCCS
0.0
80
ma
x.
in
7/38
SCCS
2.0
3
ma
x.
mm
197
198
199
507197
507198
507199
Coax
Cable
Coax
Cable
Coax
Cable
50
22.0
pF/ft
72.2
pF/m
70
16.0
pF/ft
52.5
pF/m
70
16.0
pF/ft
52.5
pF/m
PS
helix
PS
helix
PS
helix
None
PE
PE
AL
Tube
0.8
75
in
22.
2
mm
0.300
BC
AL
Tube
0.6
00
in
15.
2
mm
0.114
BC
AL
Tube
1.0
15
in
25.
8
mm
0.209
BC
AL
Tube
1.7
65
in
44.
8
mm
0.403
BC
200
507200
Coax
Cable
70
16.0
pF/ft
52.5
pF/m
201
507201
Rigid
wavegu
ide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
202
507202
Rigid
wavegu
ide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
203
507203
Rigid
wavegu
ide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
204
507204
Rigid
wavegu
ide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
205
507205
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Rigid
wavegu
PS
helix
PE
ide
206
507206
Rigid
wavegu
ide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
207
507207
Rigid
wavegu
ide
N/A
N/A
N/A
N/A
N/A
N/A
N/A
208
507208
Rigid
wavegu
ide
N/A
N/A
N/A
N/A
N/A
N/A
19/0.0
38 S
2S
0.7
50
ma
x.
in
19.
1
ma
x.
mm
19/0.0
378
SC
209*
507209
Coax
Cable
50
26.5
pF/ft
86.9
pF/m
Air
spac
e
TFE
Silicone
rubber &
FG
210*
211*
211A*
212*
507210
507211
507211A
507212
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
93
14.5
pF/ft
47.6
pF/m
50
29.3
pF/ft
96.1
pF/m
50
29.4
pF/ft
96.5
pF/m
50
30.8
pF/ft
101
pF/m
Air
spac
e
TFE
TFE
TFE
PE
FG-V
FG-V
FG-V
PVC-IIA
0.2
42
in
6.1
5
mm
0.0253
BC
BC
0.7
30
in
18.
5
mm
0.190
BC
BC
0.7
30
in
18.
5
mm
0.190
BC
2S
0.3
32
in
8.4
mm
0.0556
SC
213*
214*
215*
216*
507213
507214
507215
507216
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
50
30.8
pF/ft
101
pF/m
50
32.2
pF/ft
106
pF/m
50
30.8
pF/ft
101
pF/m
75
22.0
pF/ft
72.2
pF/m
PE
PE
PE
PE
PVC-IIA
PVC-IIA
PVC-IIA w/
armor
PVC-IIA
BC
0.4
05
in
10.
3
mm
7/0.02
96 BC
2S
0.4
25
in
10.
8
mm
7/0.02
96 SC
BC
0.4
75
in
12.
1
mm
7/0.02
96 BC
2 BC
0.4
25
in
10.
8
mm
7/26
TC
217*
218*
507217
507218
Coax
Cable
Coax
Cable
219*
507219
Coax
Cable
220*
507220
Coax
Cable
50
32.2
pF/ft
106
pF/m
50
32.2
pF/ft
106
pF/m
50
32.2
pF/ft
106
pF/m
50
30.8
pF/ft
101
pF/m
PE
PE
PE
PE
PVC-IIA
PVC-IIA
PVC-IIA w/
armor
PVC-IIA
2 BC
0.5
45
in
13.
8
mm
0.106
BC
BC
0.8
70
in
22.
1
mm
0.195
BC
BC
0.9
45
ma
x.
in
24.
0
ma
x.
mm
0.195
BC
BC
1.1
20
in
28.
0.260
BC
4
mm
221*
222*
223*
507221
507222
507223
Coax
Cable
Coax
Cable
Coax
Cable
50
30.8
pF/ft
101
pF/m
50
30.8
pF/ft
101
pF/m
50
30.8
pF/ft
101
pF/m
PE
PE
PE
PVC-IIA w/
armor
PVC-IIA
PVC-IIA
BC
1.1
95
in
30.
4
mm
0.260
BC
2S
0.3
32
in
8.4
mm
0.0556
resista
nce
2S
0.2
12
in
5.4
mm
0.035
S
Catal
og
No.
RG
/U
No.
224
*
225
*
No
m.
Im
p.
Ty
pe
507224
507225
Coa
x
Cab
le
Coa
x
Cab
le
Diele
ct.
Mat.
Ca
p.
50
30.
8
pF/f
t
101
pF/
m
50
29.
4
pF/f
t
96.
5
pF/
m
Jac
ket
PE
TFE
Overa
ll
Diam
eter
Shi
eld
PVCIIA w/
armo
r
FG-V
Size
(in)
and
Type
of
Inner
Cond.
2
BC
0.6
15
ma
x.
in
15.
6
ma
x.
mm
0.106
BC
2S
0.4
30
in
10.
9
mm
7/0.03
12 S
226
*
227
*
228
*
507226
507227
507228
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
50
29.
4
pF/f
t
96.
5
pF/
m
50
29.
4
pF/f
t
96.
5
pF/
m
50
29.
4
pF/f
t
96.
5
pF/
m
Tape
d
TFE
TFE
TFE
FG-V
FG-V
w/
armo
r
FG-V
w/
armo
r
2
BC
0.5
00
in
12.
7
mm
19/0.0
254 S
2S
0.4
90
ma
x.
in
12.
4
ma
x.
mm
7/0.03
12 S
BC
0.7
95
ma
x.
in
20.
2
ma
x.
mm
0.190
BC
228
A*
229
230
*
507228
A
507229
507230
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
50
29.
4
pF/f
t
96.
5
pF/
m
50
29.
4
pF/f
t
96.
5
pF/
m
25
100
.0
pF/f
t
328
.1
pF/
m
TFE
TFE
Rub
ber
FG-V
w/
armo
r
FG-V
Rubb
er-IV
BC
0.7
95
ma
x.
in
20.
2
ma
x.
mm
0.190
BC
0.4
60
in
11.
7
mm
7/20 S
TC,
GS,
GS
0.7
40
in
18.
8
mm
37/21
TC
231
231
A
232
507231
507231
A
507232
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
50
25.
0
pF/f
t
82.
0
pF/
m
50
25.
0
pF/f
t
82.
0
pF/
m
50
22.
0
pF/f
t
72.
2
pF/
m
PE
foam
PE
foam
PE
helix
None
None
PEIIIA
Al
tube
0.5
00
in
12.
7
mm
0.162
BC
tube
Al
tube
0.5
00
in
12.
7
mm
0.162
BC
Al
tube
1.0
15
in
25.
78
mm
0.300
BC
233
234
235
*
507233
507234
507235
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
50
22.
0
pF/f
t
72.
2
pF/
m
50
22.
0
pF/f
t
72.
2
pF/
m
50
29.
5
pF/f
t
96.
8
pF/
m
PS
helix
PS
helix
TFE
tape
PEIIIA
PEIIIA
Silico
ne
rubb
er
Al
tube
1.7
65
in
44.
83
mm
BC
tube
Al
tube
3.2
95
in
83.
69
mm
BC
tube
2S
0.4
70
ma
x.
in
11.
9
ma
x.
mm
7/21 S
236
507236
Coa
x
Cab
le
50
24.
0
pF/f
t
78.
7
pF/
m
50
24.
0
pF/f
t
78.
7
pF/
m
PS
helix
PEIIIA
Al
tube
0.6
00
in
15.
2
mm
PS
helix
None
Al
tube
0.5
00
in
12.
7
mm
0.162
BC
0.162
BC
237
507237
Coa
x
Cab
le
238
507238
Coa
x
Cab
le
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
507239
Coa
x
Cab
le
N/
A
N/A
N/A
N/A
N/A
N/A
N/A
239
240
507240
Coa
x
Cab
le
50
22.
0
pF/f
t
72.
2
pF/
m
241
507241
Coa
x
Cab
le
N/
A
N/A
PS
helix
None
Al
tube
3.1
25
in
79.
38
mm
N/A
N/A
N/A
N/A
242
243
507242
Coa
x
Cab
le
50
22.
0
pF/f
t
72.
2
pF/
m
507243
Coa
x
Cab
le
N/
A
N/A
PS
helix
None
N/A
N/A
Al
tube
1.6
25
in
41.
28
mm
BC
tube
N/A
N/A
N/A
BC
tube
N/A
244
245
507244
507245
Coa
x
Cab
le
Coa
x
Cab
le
75
15.
5
pF/f
t
50.
9
pF/
m
75
15.
5
pF/f
t
50.
9
pF/
m
PS
helix
None
Al
tube
0.8
75
in
22.
23
mm
PS
helix
PEIIIA
Al
tube
1.0
15
246
507246
Coa
x
Cab
le
75
15.
5
pF/f
t
50.
9
pF/
m
247
507247
Coa
x
75
15.
5
PS
helix
PS
helix
None
PEIIIA
Al
tube
0.5
00
in
12.
70
mm
0.102
BC
Al
tube
0.6
00
in
15.
24
mm
0.102
BC
0.188
BC
0.188
BC
Cab
le
248
507248
Coa
x
Cab
le
249
507249
Coa
x
Cab
le
250
507250
Coa
x
Cab
le
pF/f
t
50.
9
pF/
m
75
15.
0
pF/f
t
49.
2
pF/
m
75
15.
0
pF/f
t
49.
2
pF/
m
75
15.
0
pF/f
t
in
25.
78
mm
PS
helix
PS
helix
PS
helix
Al
tube
1.6
25
in
41.
28
mm
0.370
BC
PEIIIA
Al
tube
1.7
65
in
44.
83
mm
0.370
BC
None
Al
tube
None
3.1
25
in
79.
0.732
BC
49.
2
pF/
m
251
252
253
507251
Coa
x
Cab
le
507252
Coa
x
Cab
le
507253
Coa
x
Cab
le
75
15.
0
pF/f
t
49.
2
pF/
m
75
24.
4
pF/f
t
80.
1
pF/
m
75
24.
4
pF/f
t
80.
1
38
mm
PS
helix
PE
tube
PE
tube
PEIIIA
None
PE
Al
tube
3.2
95
in
83.
69
mm
0.732
BC
Al
tube
0.5
30
in
13.
46
mm
0.167
BC
Al
tube
0.6
35
ma
x.
in
16.
0.167
BC
pF/
m
254
507254
Coa
x
Cab
le
255
507255
Coa
x
Cab
le
256
507256
Coa
x
Cab
le
50
24.
4
pF/f
t
80.
1
pF/
m
50
24.
4
pF/f
t
80.
1
pF/
m
50
23.
5
pF/f
t
1
ma
x.
mm
PE
tube
PE
tube
TFE
tube
Al
tube
1.1
00
ma
x.
in
27.
94
ma
x.
mm
0.311
BC
None
Al
tube
0.9
53
in
24.
21
mm
0.311
BC
None
Al
tube
PE
0.9
53
in
24.
S tube
77.
1
pF/
m
257
507257
Coa
x
Cab
le
50
24.
4
pF/f
t
80.
1
pF/
m
24.
4
pF/f
t
80.
1
pF/
m
258
507258
Coa
x
Cab
le
50
259
507259
Coa
x
Cab
le
50
23.
5
pF/f
t
21
mm
PS
tube
PE
tube
TFE
tube
Al
tube
1.7
86
in
45.
36
mm
BC
tube
PE
Al
tube
1.9
36
ma
x.
in
49.
17
ma
x.
mm
BC
tube
None
Al
tube
None
0.3
90
in
9.9
0.115
BC
77.
1
pF/
m
260
261
262
507260
507261
507262
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
50
23.
5
pF/f
t
77.
1
pF/
m
50
23.
5
pF/f
t
77.
1
pF/
m
50
23.
5
pF/f
t
77.
1
1
mm
PE
tube
PE
tube
PE
tube
PEIIIA
None
PE
Al
tube
0.4
50
in
11.
4
mm
0.115
BC
Al
tube
3.3
70
in
85.
60
mm
BC
tube
Al
tube
3.5
20
in
89.
41
mm
BC
tube
pF/
m
263
264
264
A
507263
507264
507264
A
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
50
21.
5
pF/f
t
70.
5
pF/
m
40
38.
0
pF/f
t
125
pF/
m
40
38.
0
pF/f
t
125
pF/
m
Air
spac
e
TFE
PE
PE
None
Al
tube
0.5
00
in
12.
7
mm
PVCIIA
2
BC
2
TC
0.7
50
in
19.
1
mm
4x
19/27
BC
2
BC
2
TC
0.7
50
in
19.
1
mm
4x
19/27
BC
PU
0.172
BC
264
B
264
C
265
507264
B
507264
C
507265
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
40
42.
0
ma
x.
pF/f
t
138
ma
x.
pF/
m
40
42.
0
ma
x.
pF/f
t
138
ma
x.
pF/
m
50
22.
3
pF/f
t
73.
2
pF/
PE
PE
PS
helix
PU
2
BC
2
TC
0.7
50
in
19.
1
mm
4x
19/27
BC
PU
2
BC
2
TC
0.7
50
in
19.
1
mm
2 x 13
BC 2 x
13 TC
CC
S
tube
2.0
70
in
52.
58
mm
BC
tube
PEIIIA
266
*
267
268
507266
507267
507268
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
15
30
53.
0
pF/f
t
174
pF/
m
50
22.
2
pF/f
t
72.
8
pF/
m
50
23.
0
pF/f
t
75.
5
pF/
m
PE
PS
helix
PS
helix
PVCI
PE-III
None
BC
0.4
00
in
10.
2
mm
0.144
BC
helix
CC
S
tube
1.1
90
in
30.
23
mm
BC
tube
BC
Tub
e
0.5
00
in
12.
7
mm
0.160
BC
507
269
269
Coax
Cable
22.2
pF/ft
72.8
pF/m
50
PS
helix
1.0
05
in
25.
53
mm
BC
Tube
None
BC
tub
e
BC
Tub
e
1.8
30
in
46.
48
mm
BC
tube
270
507-270
Coax
Cable
50
22.3
pF/ft
73.2
pF/m
271
507-271
Waveguid
e
N/A
N/A
N/A
N/A
N/A
N/A
N/A
272
507-272
Waveguid
e
N/A
N/A
N/A
N/A
N/A
N/A
N/A
273
507-273
Waveguid
e
N/A
N/A
N/A
N/A
N/A
N/A
N/A
274
507-274
Waveguid
e
N/A
N/A
N/A
N/A
N/A
N/A
N/A
275
507-275
Waveguid
e
N/A
N/A
N/A
N/A
N/A
N/A
N/A
276
507-276
Waveguid
e
N/A
N/A
N/A
N/A
N/A
N/A
N/A
277
507-277
Waveguid
e
N/A
N/A
N/A
N/A
N/A
N/A
N/A
PS helix
None
278
279*
280*
281
282
507-278
507-279
507-280
507-281
507-282
Waveguid
e
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
283
507-283
Coax
Cable
284A
507284A
Coax
Cable
N/A
N/A
75
17.0
pF/ft
55.8
pF/m
50
25.4
pF/ft
83.3
pF/m
50
25.4
pF/ft
83.3
pF/m
54.6
28.2
pF/ft
92.5
pF/m
N/A
Air
space
TFE
Taped
TFE
Taped
TFE
Irradiate
d PE
N/A
FG-V
FEP-IX
SR & braid
FEP
N/A
N/A
N/A
0.1
45
in
3.6
8
mm
19/36
SCCS
2S
0.4
80
in
12.
2
mm
0.1144
BC
2S
0.7
50
in
19.
1
mm
19/0.0
378 S
2S
0.2
00
in
5.0
8
mm
0.0253
S
19/0.1
77 S
0.220
BC
46
50.0
pF/ft
164
pF/m
Rubber
Rubber-IV
2S
0.4
75
ma
x. in
12.
1
ma
x.
mm
75
15.0
pF/ft
PE helix
None
BC
Tub
1.0
05
49.2
pF/m
285A
286
287
288
507285A
507-286
507-287
507-288
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
in
25.
53
mm
BC
Tub
e
1.0
05
in
25.
53
mm
0.1140
BC
BC
Tub
e
1.8
30
in
46.
48
mm
BC
tube
BC
Tub
e
1.8
30
in
46.
48
mm
0.197
BC
CCS
tube
3.7
50
in
95.
25
mm
BC
tube
CCS
tube
N/A
100
13.0
pF/ft
42.7
pF/m
75
15.1
pF/ft
49.5
pF/m
100
13.5
pF/ft
44.3
pF/m
50
21.6
pF/ft
70.9
pF/m
PE helix
None
CCS
tube
3.7
50
in
95.
25
mm
N/A
N/A
N/A
N/A
289
507-289
Coax
Cable
75
14.7
pF/ft
48.2
pF/m
290
507-290
Waveguid
e
N/A
N/A
TFE
helix
PE helix
PE helix
PE helix
None
None
None
None
291
292
293
293A
294
294A
295
507-291
507-292
507-293
507293A
507-294
507294A
507-295
Waveguid
e
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
N/A
N/A
75
15.1
pF/ft
49.5
pF/m
50
30.8
pF/ft
101
pF/m
50
30.8
pF/ft
101
pF/m
95
16.3
pF/ft
53.5
pF/m
95
16.3
pF/ft
53.5
pF/m
50
30.8
pF/ft
101
pF/m
N/A
PE helix
PE
PE
PE
PE
PE
N/A
PE FC
PE-IIIA
PE-IIIA
PE-IIIA
PE-IIIA
PE-IIIA
N/A
N/A
N/A
BC
Tub
e
1.8
30
in
46.
48
mm
BC
tube
0.5
45
in
13.
8
mm
0.106
BC
0.5
45
in
13.
8
mm
0.106
BC
TC
0.6
30
in
16.
0
mm
0.0808
BC
0.0808
TC
0.6
30
in
16.
0
mm
0.0808
BC
0.0808
TC
0.8
95
in
22.
7
0.195
BC
mm
296*
297
298
301*
507-296
507-297
507-298
507-301
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
302*
507-302
Coax
Cable
303*
507-303
Coax
Cable
50
36.4
pF/ft
119
pF/m
50
21.4
pF/ft
70.2
pF/m
N/A
N/A
50
32.0
pF/ft
105
pF/m
Silicone
rubber
TFE
helix
PE
TFE
Neoprene
None
PE foam
FEP-IX
1.1
90
in
30.
23
mm
37/0.0
336 S
BC
Tub
e
1.0
05
in
25.
53
mm
BC
tube
Non
e
0.6
50
in
16.
5
mm
7/24
CCS
HR
0.2
45
in
6.2
2
mm
7/0.02
03 HR
0.025
SCCS
0.039
SCCS
75
19.5
pF/ft
64.0
pF/m
TFE
FEP-IX
0.2
06
ma
x. in
5.2
3
ma
x.
mm
50
29.4
pF/ft
96.5
TFE
FEP-IX
0.1
70
in
pF/m
304*
305
306A
307A*
507-304
507-305
507306A
507307A
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
50
29.4
pF/ft
96.5
pF/m
75
19.5
pF/ft
64.0
pF/m
75
16.9
pF/ft
55.4
pF/m
4.3
2
mm
TFE
FEP
PE foam
FEP-IX
PE-IIIA
PE-IIIA
2S
0.2
80
in
7.1
1
mm
0.059
SCCS
BC
Tub
e
1.9
90
in
50.
55
mm
BC
tube
AL
Tub
e
1.0
15
in
25.
78
mm
0.173
BC
2S
0.2
70
ma
x. in
6.8
6
ma
x.
mm
19/0.0
058 S
7/0.00
67
SCCS
2 cond.
75
16.7
pF/ft
54.8
pF/m
TFE
FEP-IX
0.0
98
in
2.4
9
mm
FEP
Neoprene
TC
0.7
316*
507-316
Coax
Cable
50
29.4
pF/ft
96.5
pF/m
317
507-317
Coax
95
15.4
PE foam
PE-IIIA
Cable
318
319
321
322
507-318
507-319
507-321
507-322
Coax
Cable
Coax
Cable
Coax
Cable
Coax
Cable
pF/ft
50.5
pF/m
10
in
18.
0
mm
7/0.02
9 BC
BC
Tub
e
1.1
00
in
27.
94
mm
BC
tube
O.D.
0.3580
I.D.
0.2870
BC
Tub
e
1.9
70
in
50.
04
mm
BC
tube
O.D.
0.6880
I.D.
0.5880
BC
Tub
e
2.8
50
in
72.
39
mm
BC
tube
BC
Tub
e
3.0
40
in
77.
22
mm
BC
tube
BC
tube
BC
tube
50
22.2
pF/ft
72.8
pF/m
50
22.3
pF/ft
73.2
pF/m
50
21.7
pF/ft
71.2
pF/m
50
21.7
pF/ft
71.2
pF/m
PE foam
PE FC
BC
Tub
e
1.0
60
in
26.
92
mm
PE foam
None
BC
Tub
0.9
80
323
507-323
Coax
Cable
50
25.6
pF/ft
84.0
pF/m
324
507-324
Coax
Cable
50
25.6
pF/ft
PE helix
SS PS
SS PE
SS PE
PE-IIIA
PE-IIIA
None
PE FC
84.0
pF/m
325
326
327
32
8*
50
732
8
Coax
Cable
507-325
Coax
Cable
507-326
507-327
Coax
Cable
Coa
x
Cab
le
85.
0
pF/f
t
278
.9
pF/
25
50
50
50
Rubbe
re
26.3
pF/ft
86.3
pF/m
26.3
pF/ft
86.3
pF/m
26.3
pF/ft
86.3
pF/m
Neopren
e
PE
spline
PU
PE
spline
PU
PE
spline
TC,
GS,
TC
PU
1.4
60
in
37.
08
mm
TC
braid
in
24.
9
mm
2
SC
strip
0.4
65
ma
x. in
11.
8
ma
x.
mm
19/0.0
200
SCCA
2
SC
strip
0.7
79
ma
x. in
19.
8
ma
x.
mm
19/0.0
400
SCCA
2
SC
strip
1.1
8
ma
x. in
30.
0
ma
x.
mm
19/0.0
640
SCCA
32
9*
33
0
33
1
50
732
9
50
733
0
50
733
1
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
33
2
50
733
2
Coa
x
Cab
le
33
3
50
733
3
Coa
x
Cab
le
50
50.
0
pF/
ft
164
pF/
m
50
25.
0
pF/
ft
82.
0
pF/
m
50
25.
0
pF/
ft
82.
0
pF/
m
50
25.
0
pF/
ft
82.
0
pF/
m
50
25.
0
pF/
ft
82.
0
Rubb
er
PE
foam
PE
foam
PE
foam
PE
foam
Neopren
e
None
PE-IIIA
None
PE-IIIA
TC,
GS,
TC
0.7
00
in
17.
8
mm
19/0.01
17 TC
SC
0.2
42
in
6.1
5
mm
SC
Al
tub
e
0.6
25
in
15.
9
mm
0.162
BC
Al
tub
e
0.8
75
in
22.
2
mm
0.288
BC
Al
tub
e
1.0
52
max
. in
26.
72
0.288
BC
pF/
m
33
4
33
5
33
6
50
733
4
50
733
5
50
733
6
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
max
.
mm
75
17.
0
pF/
ft
55.
8
pF/
m
75
17.
0
pF/
ft
55.
8
pF/
m
75
16.
5
pF/
ft
54.
1
pF/
m
PE
foam
PE-IIIA
Al
tub
e
0.8
25
in
21.
0
mm
PE
foam
PE-IIIA
BC
Tub
e
0.6
20
in
36
0
50
736
0
Coa
x
Cab
le
50
25.
0
pF/
ft
82.
0
pF/
m
36
6
50
736
Coa
x
Cab
50
26.
6
pF/
PE
foam
PE
foam
PE
foam
None
PE-IIIA
None
Al
tub
e
0.5
00
in
12.
7
mm
0.098
BC
Al
tub
e
0.6
25
in
15.
9
mm
0.098
BC
Al
tub
e
0.8
75
in
22.
2
mm
0.173
BC
0.243
BC
0.160
BC
36
7
36
9
50
736
7
50
736
9
le
Coa
x
Cab
le
Coa
x
Cab
le
ft
87.
3
pF/
m
50
21.
7
pF/
ft
71.
2
pF/
m
50
23.
5
pF/
ft
77.
1
pF/
m
50
24.
0
pF/
ft
78.
7
pF/
m
15.
7
mm
PE
helix
PE
tubes
PE-IIIA
PE-IIIA
BC
Tub
e
5.2
00
in
132
.1
mm
BC
tube
Al
tub
e
0.4
70
in
11.
9
mm
0.177
BC
Al
tub
e
0.3
90
in
9.9
1
mm
0.177
BC
0.0508
BC
0.0285
BC
37
0
50
737
0
Coa
x
Cab
le
37
3
50
737
3
Coa
x
Cab
le
N/
A
N/A
PE
PE foam
No
ne
0.6
50
in
16.
5
mm
37
4
50
737
Coa
x
Cab
N/
A
N/A
PE
PE foam
No
ne
0.6
50
in
PE
tubes
None
37
6
37
7
50
737
6
50
737
7
le
Coa
x
Cab
le
Coa
x
Cab
le
16.
5
mm
50
26.
0
pF/
ft
85.
3
pF/
m
50
24.
0
pF/
ft
78.
7
pF/
m
PE
helix
PE-IIIA
Al
tub
e
2.0
00
in
50.
8
mm
N/A
N/A
N/A
N/A
N/A
No
ne
0.6
50
in
16.
5
mm
2 cond.
0.0403
37
8
50
737
8
Coa
x
Cab
le
50
22.
1
pF/
ft
72.
5
pF/
m
38
2
50
738
2
Rigi
d
Line
N/
A
N/A
38
3
50
738
3
Coa
x
Cab
le
10
0
N/A
PE
foam
TFE
tubes
PE
PE-IIIA
None
PE foam
Al
tub
e
1.0
60
in
26.
9
mm
0.312
BC
tube
Al
tub
e
0.5
30
in
13.
5
mm
0.165
S tube
BC
tube
38
4
50
738
4
Coa
x
Cab
le
38
5
50
738
5
Coa
x
Cab
le
38
6
50
738
6
Coa
x
Cab
le
38
8
50
738
8
Coa
x
Cab
le
50
30.
8
pF/
ft
101
pF/
m
50
25.
4
pF/
ft
83.
3
pF/
m
PE
SS
TFE
PE foam
Optional
Flat
BC
0.6
50
in
16.
5
mm
0.16
BC
AL
Tub
e
0.6
60
in
16.
8
mm
0.153
S
No
ne
0.6
50
in
16.
5
mm
0.0508
CCS
0.5
45
in
13.
8
mm
0.1020
BC
0.250
BC AL
7/26
TC
N/
A
N/A
50
30.
8
pF/
ft
101
pF/
m
PE
PE-IIIA
2S
0.8
75
in
22.
2
mm
C PE
& PE
PVC-IIA
TC
0.4
05
38
9
50
738
9
Coa
x
Cab
le
50
22.
8
pF/
ft
74.
8
pF/
m
39
1*
50
7-
Coa
x
72
23.
0
PE
PE
PE foam
PE-IIIA
39
1
39
2*
39
3*
40
0*
40
1*
50
739
2
50
739
3
50
740
0
50
740
1
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
pF/
ft
75.
5
pF/
m
72
23.
0
pF/
ft
75.
5
pF/
m
50
29.
4
pF/
ft
96.
5
pF/
m
50
29.
4
pF/
ft
96.
5
pF/
m
50
29.
4
pF/
ft
96.
5
pF/
m
in
10.
3
mm
C PE
& PE
TFE
TFE
TFE
PVC-IIA
FEP-IX
FEP-IX
None
TC
0.4
75
in
12.
1
mm
7/26
TC
2S
0.3
90
in
9.9
mm
7/0.031
2S
2S
0.1
95
in
4.9
5
mm
19/0.00
77 S
BC
Tub
e
0.2
50
in
6.3
5
mm
0.0641
S
40
2*
40
3*
40
4*
40
5*
50
740
2
50
740
3
50
740
4
50
740
5
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
Coa
x
Cab
le
50
29.
4
pF/
ft
96.
5
pF/
m
50
29.
4
pF/
ft
96.
5
pF/
m
50
31.
5
pF/
ft
103
pF/
m
50
29.
4
pF/
ft
96.
5
pF/
m
TFE
TFE
TFE
TFE
None
FEP-IX
FEP-IX
None
BC
Tub
e
0.1
41
in
3.5
8
mm
0.0360
SCCS
2S
0.1
04
in
2.6
4
mm
7/38
SCCS
0.0
75
max
. in
0.1
91
max
.
mm
7/38
SCCS
BC
Tub
e
0.0
86
in
2.1
8
mm
0.0201
SCCS
Specifications
Image
RG213
Impedance: 50 ohms
RG214
Impedance: 50 ohms
LMR400
Impedance: 50 ohms
9913
Impedance: 50 ohms
RG8X
RG58U
Impedance: 50 ohms
Attenuation: 2.5 dB per 100 ft at 30 MHz and less
While not a coax cable, it seemed appropriate to include a reference to Ladder Line on this page as well
Ladder
Line
Attenuation: NA