Case study
Segment is consisting of: 1 vessel and 5 pipes
Vessel
23-VG02A
WT mm
60
LL mm
1000
WL mm
0
OD WT Length UTS mm mm mm Material MPa Phase 168,3 7,11 8846 CS_235LT 420 Gass 406,4 12,7 2107 Duplex_22Cr 730 Gass 168,3 7,11 1953 CS_360LT 545 Liquid 323,8 9,53 25589 SS_6Mo 620 Liquid 219,3 3,76 5000 CS_360LT 545 Gass
MT CA Insulation layer Peak heat load Backgrond heat load % mm 1st layer mm 2nd layer mm Mantel mm kW/m2 kW/m2 12,5 0 Foamglas 20 Carbowool 50 SS 0,7 350 100 12,5 3 350 100 12,5 3 350 100 12,5 0 350 100 12,5 0 350 100
Operational conditions
Inventory conditions
Temperature 47 C Pressure 38 bar g
Fluid composition
C1 C2 C3 H2O C4 IC4 C10 C8 C5 IC5 C6 0.75868 0.100594 0.0577988 0.05 0.015507 0.00523613 0.00352432 0.00342362 0.00241668 0.00231598 0.000503474
Outside exposure
Outside conditions
Temperature 10 C Outside emissivity 0,85 Back pressure 0 bar g
Heat load
Peak heat load 350 kW/m2 Background heat load 100 kW/m2
Valves
PSV
type: trapezium characteristic
Equivalent opening 54 mm
Contraction factor 0,84 Location 1 0 Set pressure (opening) 42 bar g Full open pressure 44 bar g Reset pressure 30 bar g
Type of PSV
Petrell as Olav Tryggvasonsgt. 40 NO-7011 Trondheim Phone: (+47) 73 80 55 00 Fax: (+47) 73 80 55 01 E-mail: petrell.petrell.no www.petrell.no www.vessfire.com