Daikin units comply with the European regulations that guarantee the safety of the product.
Daikin Europe NV is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
VRV Commercial Hydronic Guarantee VRV Residential Long Life Europe Hydronic Long Life Residential Reliability Guarantee Residential Quality Commercial Industrial Environment Hydronic Quality Long Life Guarantee Safety Europe Long Life VRV Environment Quality Residential Commercial Residential Accurate
Safety
Daikin Europe NV is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products.
Environment Residentia
Reliability
1999
Guarantee Commercial
Safety
Hydronic
Environment
Quality
Commercial
Safety
Long Life
Residential
Hydronic
Commercial Residential
Environment
Commercia
Commerc Europe
Quality
Reliability
Residential Reliability
Commercial
Residential VRV
Environment
VRV
To consult the explanation of the pictogrammes, please open the flap of this catalogue.
Infrared remote control Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance. Wired remote control Wired remote control to start, stop and regulate the air conditioner from a distance. Centralised control Centralised control to start, stop and regulate several air conditioners from one central point.
Auto-swing Possibility to select automatic moving of the air discharge louvre, for uniform air flow and temperature distribution.
Draught prevention When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired. Auto-restart The unit restarts automatically at the original settings after power. Auto cooling-heating changeover Automatically selects cooling or heating mode to achieve the set temperature (heat pump types only). Dry programme Allows humidity levels to be reduced without variations in room temperature. Fan only The air conditioner can be used as fan, blowing air without cooling or heating. Auto fan speed Automatically selects the necessary fan speed to reach or maintain the set temperature. Fan speed steps Allows to select up to the given number of fan speed. Timer Allows to preset the air conditioner to start/stop at a specified time. 24 Hour timer Timer can be set to start cooling/heating anytime during a 24-hours period. Night set mode Saves energy, by preventing overcooling or overheating during night time. Ceiling soiling prevention A special function prevents air blowing out too long in horizontal position, to prevent ceiling stains. Self-diagnosis Simplifies maintenance by indicating system faults or operating anomalies. Scroll compressor Silent, reliable Daikin compressor used in medium sized outdoor units. Energy efficiency Daikin air conditioners are energy efficient and economical. Whisper quiet Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet of the neighbourhood. Double thermostat function Controls the temperature via a sensor on the air conditioner or via a sensor on the remote control. Air filter Removes airborne dust particles to ensure a steady supply of clean air. Air purification filter Removes airborne dust particles and prevents the propagation of bacteria and viruses to ensure a steady supply of clean air. Drain pump kit Facilitates condensation draining from the indoor unit. Twin/triple/double twin application 2, 3 or 4 indoor units can be connected to only 1 outdoor unit even if they have different capacities. All indoor units operate within the same mode (cooling or heating) from one remote control. Multi model application Up to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode. Powerful mode If the temperature in the room is too high/low, it can be cooled down/heated quickly by selecting the powerful mode. After the powerful mode is turned off, the unit returns to the preset mode. Movement sensor The sensor detects whether someone is in the room. When the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room. Comfortable sleeping mode Increased comfort function that follows a specific temperature fluctuation rhythm.
Power supply
T1 = 3~, 220V, 50Hz V1 = 1~, 230V, 50Hz VE = 1~, 230V, 50Hz W1 = 3N~, 400V, 50Hz Y1 = 3~, 400V, 50Hz
Measuring conditions
COOLING ONLY
1) nominal cooling capacities are based on: indoor temperature outdoor temperature refrigerant piping length level difference 27CDB/19CWB (UAT: 19.5CWB/FWHC: 19.4CWB) 35CDB 7.5m - 8/5m VRV 0m
HEAT PUMP
1) nominal cooling capacities are based on: indoor temperature outdoor temperature refrigerant piping length level difference 2) nominal heating capacities are based on: indoor temperature outdoor temperature refrigerant piping length level difference 27CDB/19CWB (UATY: 19.5CWB) 35CDB/24CWB 7.5m - 8/5m VRV 0m 20CDB/12CWB (UATY: 21CDB) 7CDB/6CWB 7.5m - 8/5m VRV 0m
F oreword
MIGHTY OAKS FROM LITTLE ACORNS GROW In 1972, Daikin Industries Ltd, established its European headquarters in Ostend, Belgium in answer to the rapidly growing European demand for high quality air conditioning. Perceived at first, simply as an assembly centre for Japanese manufactured equipment, the nascent plant - occupying a mere 5,000 m2 - soon evolved into a supply base for a Europe wide distribution network. Since those early years, Daikin Europe has benefited from continuous investment on the part of its parent company and now enjoys a position of pre eminence among the largest and best known names in European air conditioning. The companys record of spectacular growth in both turnover and production capacity is to be envied among engineering manufacturers in general and the air conditioning sector in particular. Widely recognised as the most advanced air conditioning production facility in Europe, the Ostend plant is responsible for well over 80% of Daikin Europe products and occupies a site approaching 150,000 m2.
CHILLERS:
EUWA-HD(Z) / EUWA*-KA(X) / EUWA*-LZ / EUWAC-FA: EUWY-HD: EUW-KX: EUW(H)-FA/FB: EUWL*-KX: Fan coils: evaporator: 12C/7C; evaporator: 12C/7C; condenser: 40C/45C; evaporator: 12C/7C; evaporator: 12.5C/7C; evaporator: 12.5C/7C; cooling: heating: FWHC: cooling: heating: ambient: 35C ambient: 35C ambient: 7CDB/6CWB condenser: 30C/35C (cooling); 40C/45C (heating) condenser: 29,5C/35C (cooling); 39.5C/45C (heating) condensing temperature: 40OC ambient 27CDB/19CWB entering water temperature 7C ambient 20CDB entering water temperature 50C ambient 26.7CDB/19CWB entering water temperature 7.2C ambient 20CDB entering water temperature 60C
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks). The sound power level is an absolute value indicating the power which a sound source generates. For more detailed information please consult our technical databooks. 78 3
3 4 7
3. Hi-VRV
The complete air conditioning system Variable Refrigerant Volume VRV Inverter heat pump series VRV Heat recover y series VRV Plus series using R-407C VRV Plus series using R-22 VRV Indoor units Heat Recovery Ventilation Daikin Air Conditioning Management System Hi-VRV Selection programme 44 46 46 47 48 New 49 50 57 New 58 59
10 11 12 13 14 15 16 17 18 19
New
New
T able of contents
4. HYDRONIC SYSTEMS
CHILLERS Power & precision Air Cooled EUWA/Y EUWA-HZ EUWA* EUWA*-KX EUWA*-LZ EUWAC HYDRAULIC MODULE EHMC FAN COIL UNITS FWV(M)/FWH(M)/FWHC 72 71 61 62 63 64 65 66 67 Water Cooled /Remote Condenser EUW(H) EUW(L)*-KX DICN Daikin Integrated Chiller Network
68 69
70
OUTDOOR UNITS Pair application - cooling only Pair application - heat pump Pair application - Inverter controlled Sky air application - Inverter controlled Condensing units ER/ERC Multi model application - possible indoor units Multi model application Multi model application - Inverter controlled Twin/triple/double twin application
4
35 36 37 38 39 40 41 42 43
5. CONDENSING UNITS
ER POWER SUPPLY & MEASURING CONDITIONS 77 78
5
D aikin Europe
THE PRODUCTS
Daikin Europe designs and produces an extensive range of hi tech air conditioning equipment, including air and water cooled chillers, packaged air conditioners, splits and multi splits, VRV and Sky Air systems for commercial, industrial and residential comfort cooling and process applications. Around 95% of production is exported via the companys distribution network to countries stretching from Scandinavia to Africa.
DAIKIN QUALITY
Daikins much envied quality levels, stem quite simply from the close attention paid to design, production and testing procedures as well as post sales support. To this end, every bought in component is carefully selected and rigorously tested to verify its contribution to product quality and reliability.
TRAINING
The continual application of leading edge technology to air conditioning has considerable bearing on the likely future shape and direction of the European market and only a thorough understanding of new generation Daikin products and systems will enable their full commercial potential to be realised. Training has long been accepted as a cornerstone of the companys sales development and customer support programmes and is vital if a broader understanding of the present and future impact of air conditioning is to be achieved.
1
STYLISH AND ELEGANT
Daikin residential air conditioning is the modern, economic and efficient way to switch on to springtime - in the living room, dining room, kitchen or bedroom, night and day, throughout the year. Daikin air conditioning units are easy to install, easy to use, ultra reliable, quiet running and come in an elegant and up to date range of wall, floor and ceiling mounted indoor models. Also, the incorporation of inverter control enables Daikin to bring air conditioning technology of the future to the residential market today. Inverter control cuts start up time and energy consumption by almost a third, alters unit output to suit outdoor conditions, improves performance relative to power input, ensures a more even room temperature and eliminates power surges and stop/start cycles.
optional
FTY
optional
FT(Y)18/25(22)/35G
FT 5 steps
FT25-35GZV1NB
p.40
5 steps
p.40
FT(Y)40G
WA L L M O U N T E D U N I T
FT(Y)-G
FT-GZ
FT45GZV1NB
WA L L M O U N T E D U N I T
lightweight and compact efficient and even horizontal and vertical air distribution air purification and deodorizing filter easily washable front panel
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit HxWxD H/L H/L H see page kW kW mm kg m3/min dB(A) dB(A) 35
FT18GV1B
1.8 0.55 7 7.3/4.7 36/26 51 RE-GA7V1
FT25GV1B
2.45 0.86 250x750x180 7 6.6/4.2 36/26 51
FT35GV1B
3.30/3.35 1.27 7 7.8/5.5 39/31 54
FT40GV1B
4.15 1.58 298x790x189 9 8.6/6.0 41/32 55 RE-GA7V1
FT45GV1B
5.25
FT60GV1B
6.35
RE-GA7V1/R-DC7V11 RE-GA7V1/R-DC7V11
optimised for use with R-407C swing compressor lightweight and compact automatic airflow director ensures uniform airflow and temperature distribution optimised unit in new and smaller casing powerful mode can be selected for rapid cooling washable front panel energy efficient
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions Weight Air flow rate (H/L) Sound pressure level (H/L) cooling heating HxWxD cooling heating cooling heating kW kW kW kW mm kg m3/min m3/min dB(A) dB(A) dB(A) 36
FTY18GV1B
1.85 1.85 0.59 0.52 7 7.1/4.5 6.6/4.8 36/26 35/26 51 REY-GA7V1
FTY22GV1B
2.55/2.40 3.20/2.65 1.10/0.86 1.14/0.78 250x750x180 7 6.6/4.2 7.3/4.8 36/26 35/26
FTY35GV1B
3.50/3.25 4.10/3.60 1.44/1.19 1.50/1.22 7 7.8/5.5 8.0/5.9 39/31 38/30
FTY40GV1B
3.9 4.7 1.63 1.62 298x790x189 9 8.6/6.0 9.7/7.6 40/33 41/33 55 REY-GA7V1
FTY45GV1B FTY60GV1B
4.9 5.55 2.06 1.90 298x1,050x190 12 11.8/9.5 14.9/10.0 43/36 44/34 58 RY-DB7V1 12 13.3/9.8 15.5/11.1 46/38 45/34 61 RY-FA7V1 6.0 7.15 2.43 2.4 Refrigerant: R-407C Power supply: V1: 1~, 230V, 50 Hz
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit HxWxD H/L H/L H see page kW kW mm kg m3/min dB(A) dB(A) 35
FT25GZV1NB
2.4 0.84 250x750x180 7 6.6/4.2 36/26 51 R-GZ7V11
FT35GZV1NB
3.45 1.24 7 7.8/5.5 39/31 55 R-GZ7V11
FT45GZV1NB
5.1 2.10 (V11)/2.0(W11) 298x1,050x190 12 11.8/9.1 43/36 58 R-GZ7V11/W11
11
51 54 RY-DB7V1/REY-GA7V1 RY-DA7V1/REY-GA7V1
optional
FTX only
optional
FTX only
New
WA L L M O U N T E D INVERTER CONTROLLED UNIT
p. 43
FTK only
5 steps
p. 43
FTK only
5 steps
FTX/FTK-JA
FTX/FTK-H
consumes 30% less power than noninverter models achieves set temperature more quickly diffuser and flexible louvre improves air distribution easily washable front panel air purification and deodorizing filter supersilent operation movement sensor:
An infrared sensor on the unit automatically detects the presence of any occupant in the room within 5m. As long as the room remains occupied, the unit functions normally but will switch to economy mode 20 minutes after the occupant leaves. This important new feature prevents energy wastage in empty rooms and cuts power consumption by 30% in heating mode and 20% in cooling mode. Air conditioning will start up again as soon as anybody enters an empty room, establishing all round comfort in virtually no time at all. The sensor can be positioned vertically or horizontally, on either the left or right of the unit.
consumes 30% less power than noninverter models achieves set temperature more quickly the indoor units are equipped with an automatic vertical airflow director diffuser and flexible louvre improves air distribution easily washable front panel air purification and deodorizing filter supersilent operation
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz Pair/Multi Pair/Multi Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz
CO/HP
Cooling capacity (1) Heating capacity (1) Nominal input (1) Dimensions Weight Air flow rate (H/L) Sound pressure level (H/L) Sound power level (H) Outdoor unit
12
FTK25JAV1NB
min.-nom.-max kW min.-nom.-max kW cooling heating HxWxD cooling heating cooling heating cooling heating see page kW kW mm kg m3/min m3/min dBA dBA dBA dBA 37 1.3 ~ 2.5 ~ 3.0 0.43 ~ 0.94 ~ 1.25 -
FTK35JAV1NB
1.4 ~ 3.5 ~ 3.8 0.47 ~ 1.35 ~ 1.72 -
FTX25JAV1NB
1.3 ~ 2.5 ~ 3.0 1.3 ~ 3.4 ~ 4.0 0.35 ~ 0.98 ~ 1.35 0.35 ~ 1.13 ~ 1.35
FTX35JAV1NB
1.4 ~ 3.43 ~ 3.8 1.4 ~ 4.1 ~ 5.1 0.5 ~ 1.43 ~ 1.72 0.4 ~ 1.38 ~ 1.9 7.5 7.4/4.7 8.4/5.9 39/27 39/27 55 55 RX-JV1NB Sound pressure level (H/L) Sound power level Outdoor unit
Multi
Multi
CO/HP
Cooling capacity (1) Heating capacity (1) Nominal input Dimensions Weight Air flow rate (H/L) cooling heating cooling heating H see page min.-nom.-max kW min.-nom.-max kW cooling heating HxWxD kW kW mm kg m3/min m3/min dBA dBA dBA 37
FTK50HV1NB
* * -
FTK60HV1NB
* * -
FTX50HV1NB
* * * *
FTX60HV1NB
* * * *
273x784x185 7.5 7.1/4.9 38/26 54 RK-JV1NB 7.5 7.4/4.7 39/27 55 RK-JV1NB 7.5 7.1/4.6 8.4/5.7 38/26 38/26 54 54 RX-JV1NB
273x784x185
(1) Units should be selected on nominal capacity. Maximum capacity is limited to peak periods.
*Capacity and nominal input depend on the combinations between outdoor unit and indoor units. (1) Units should be selected on nominal capacity. Maximum capacity is limited to peak periods.
optional
optional
5 steps
CDK
optional
p.43
FTX-JZ
CDK/CDX-HA
optimised for use with R-407C swing compressor highly energy efficient - consumes 30% less energy super silent operation compact washable and easily removable front panel
highly energy efficient consumes 30% less energy lightweight and compact only suction and discharge grilles are visible blends unobtrusively into any interior decor extremely quiet in operation both indoors and outdoors
CDK25HAV1NB
* * 23 13.0/11.0 39/36 55
CDK35HAV1NB
* *
CDK50HAV1NB
* *
CDK60HAV1NB
* * 24 14.5/11.5 44/41 60
260x900x580 23 13.0/11.0 39/36 55 4MK90HV1NB Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz 24 13.0/11.0 42/39 58
HEAT PUMP
Cooling capacity (1) Heating capacity (1) Nominal input (1) Dimensions Weight Air flow rate (H/L) Sound pressure level (H/L) min.-nom.-max kW min.-nom.-max kW cooling heating HxWxD cooling heating cooling heating kW kW mm kg m3/min m3/min dB(A) dB(A)
FTX25JZV1NB
1.5 ~ 2.6 ~ 3.1 1.5 ~ 3.6 ~ 4.6 0.5 ~ 1.0 ~ 1.3 0.46~ 1.21 ~ 1.53 273x784x185 7.5 7.1/5.2 8.4/5.9 38/30 38/30 55 RXT25JZV1NB
FTX35JZV1NB
1.5 ~ 3.45 ~ 3.6 1.5 ~ 4.2 ~ 4.8 0.5 ~ 1.5 ~ 1.55 0.46 ~ 1.52 ~ 1.76 7.5 7.4/5.2 8.7/5.9 39/31 39/31 55 RXT35JZV1NB
CDX25HAV1NB
* * * 23 13.0/11.0 39/36 40/36 55/56
CDX35HAV1NB
* * *
CDX50HAV1NB
* * *
CDX60HAV1NB
* * * 24 14.5/11.5 44/41 44/40 60/60
Sound power level (H) cooling/heating dB(A) 37 Outdoor unit see page (1) Units should be selected on nominal capacity. Maximum capacity is limited to peak periods.
14
Sound power level (H) cooling/heating dBA 42 Outdoor unit see page
* Capacity and nominal input depend on the combinations between outdoor unit and indoor units.
15
FVY/FCVY
FV only
optional
FVY
optional
5 steps
FVY only
p.40
FV only
F L O O R S TA N D I N G U N I T
FV(Y)/FCVY-D
FVXT-G
F L O O R S TA N D I N G INVERTER
can be installed against a wall or recessed compact design horizontal and/or vertical air distribution remote control (FVY/FCVY) or wired remote control (FV)
consumes 30% less power than non-inverter models PAM (Pulse Amplitude Modulation) inverter technology lightweight and compact can be installed against a wall or recessed dual air discharge blow for better air distribution washable air suction grille air purification filter
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit H/L H/L H see page HxWxD kW kW mm kg m3/min dB(A) dB(A) 35
FV25D7V1
2.38 0.91 19 9.3/6.5 39/31 47 R-DC7V11
FV35D7V1
3.48 1.37 600x750x205 19 9.3/6.5 40/32 48 R-DC7V11
FV45D7V1
5.13 2.23 19 11.0/8.7 43/37 51 R-DC7V11/W11
FV60D7V1
6.35 2.35 600x870x205 22 12.5/11.2 46/40 54 R-FA7V1/W1 Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz
HEAT PUMP
Cooling capacity (1) Heating capacity (1) Nominal input (1) Dimensions Weight Air flow rate (H/L) Sound pressure level (H/L) min.-nom.-max kW min.-nom.-max kW cooling kW heating HxWxD cooling heating cooling heating kW mm kg m3/min m3/min dB(A) dB(A) * * * *
FVXT40GV1NB
0.9 - 4.0 - 4.5 0.9 - 6.0 - 7.5 0.19 - 1.26 - 1.46 0.19 - 1.86 - 2.81 600x650x195 13 9.6 - 7.1 12.5 - 8.7 41/34 43/34 53 RXT40GV1NB
FVXT50GV1NB
0.9 - 5.0 - 5.2 0.9 - 6.6 - 7.7 0.19 - 2.08 - 2.11 0.19 - 2.35 - 3.05 13 10.8 - 7.7 13.2 - 9.4 44/36 45/36 56 RXT50GV1NB
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions Weight Air flow rate (H/L) Sound pressure level (H/L) cooling heating HxWxD cooling heating cooling heating kW kW kW kW mm kg m3/min m3/min dB(A) dB(A)
FVY223D7V1
2.4 3.2 1.09 1.17
FVY353D7V1
3.6 4.1 1.48 1.50
600x750x205 19 9.0/6.3 10/7.4 38/30 39/30 46/47 RY-DB7V1 19 9.3/6.5 10.3/7.4 40/31 41/30 48/49 RY-DA7V1
Sound power level (H) cooling/heating dB(A) 36/41 Outdoor unit see page
16
Sound power level (H) cooling/heating dB(A) 37 Outdoor unit see page (1) Units should be selected on nominal capacity. Maximum capacity is limited to peak periods.
* Capacity and nominal input depend on the combinations between outdoor unit and indoor units. ** FCVY-D is not within the scope of the Eurovent certification programme.
17
FHEYB
FHEB
optional
FLY only
p.40
2 steps
p.40
FL only
5 steps
FHE(Y)B-BA/GZ
FL(Y)-G
compact suction and discharge grilles only are visible rear or bottom air suction drain pan on left or right ideal for use in hotel bedrooms the air duct between the indoor unit and discharge grille can be up to 0.5m long forced ON/OFF function: energy saving and comfort increasing feature
lightweight can be fitted on either ceiling or lower part of wall (e.g. beneath a window) powerful mode ensures a quick adaptation to temperature variations automatic airflow director ensures uniform airflow and temperature distribution
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound power level Outdoor unit HxWxD H/L H/L see page kW kW mm kg m3/min dB(A) dB(A) 35
FHEB18BA7V1
1.7 0.54 230x652x502 17 6.5/5.2 34/28 53/49 RE-GA7V1
FHEB25GZ7V1*
2.4/2.4 0.88/0.88 17 6.5/5.2 35/28 55/49 RE-GA7V1 (R-22) / R-GZ7V1 (R-407C)
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit HxWxD H/L H/L H see page kW kW mm kg m3/min dB(A) dB(A) 35
FL25GV1NB
2.45 0.86 16 7.5/6.0 37/31 50 R-DC7V11/RE-GA7V1
FL35GV1NB
3.35/3.30 1.27
FL40GV1NB
4.15 1.63 490x1,050x200 17 6.5/5.1 39/33 52 R-DC7V11/RE-GA7V1
FL45GV1NB
5.25 2.13(V11)/2.02(W11) 17 10.7/6.1 47/36 59 R-DC7V11/W11
*FHEB25GZ7V1 can be used in combination with an R-22 or R-407C outdoor unit. Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions Weight Air flow rate (H/L) Sound pressure level (H/L) cooling heating HxWxD cooling heating cooling heating kW kW kW kW mm kg m3/min m3/min dB(A) dB(A)
FHEYB18BA7V1
1.8 1.85 0.62 0.58 230x652x502 17 6.5/5.2 6.95/5.2 34/28 34/29 53/53 REY-GA7V1
FHEYB22BA7V1
2.2 2.5 0.88 0.82 17 6.5/5.2 6.95/5.2 35/28 35/29 55/55 REY-GA7V1
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions Weight Air flow rate (H/L) Sound pressure level (H/L) Sound power level Outdoor unit cooling heating cooling heating H see page cooling heating HxWXD kW kW kW kW mm kg m3/min m3/min dB(A) dB(A) dB(A) 36
FLY22GV1NB
2.55/2.4 3.2/2.65 1.16/0.87 1.14/0.79 17 7.6/6.0 9.2/7.4 37/31 37/31 50 RY-DB7V1/REY-GA7V1
FLY35GV1NB
3.5/3.25 4.1/3.6 1.47/1.23 1.5/1.23
FLY40GV1NB
3.9 4.7 1.63 1.62
FLY45GV1NB
4.9 5.55 2.06 1.90 18 10.7/6.3 11.5/6.9 47/37 47/36 59 RY-DB7V1
19
490x1,050x200 17 8.7/6.6 10.0/8.0 38/32 39/33 51 RY-DA7V1/REY-GA7V1 18 7.0/5.2 7.8/5.7 40/34 40/34 52 REY-GA7V1
Sound power level (H) cooling/heating dB(A) 36 Outdoor unit see page
18
2
COMFORT AND FLEXIBILITY
In offices, hotels, shops, restaurants and many other commercial premises, high levels of personal comfort and satisfaction achieved by the application of Daikin air conditioning, enhance the environment and help set the scene for increased business prosperity - economically, efficiently and discreetly. User friendly, quiet running, ultra reliable and easy to control, Daikin air conditioning adds that cool, fresh, relaxing extra something to the indoor climate, providing the perfect platform for commercial success. Available in a wide range of modern, stylish wall, floor and ceiling mounted models, Daikin air conditioning is designed to harmonise with any interior decor and fits rooms of any shape or size.
21
optional
optional
FHY only
heat pump
optional
optional
FHY only
heat pump
2 steps
FH 35 ~60 p.40
2 steps
FH only p.40
FH(Y)-FJ
FH(Y)-GZ
the ideal solution for shops, restaurants or offices without false ceilings leaves maximum floor and wall space for furniture, decoration and fittings. air flow distribution pattern can be adapted to suit ceiling heights up to 3.8m without loss of capacity.
leaves maximum floor and wall space for furniture, decoration and fittings extremely quiet in operation both indoors and outdoors automatic airflow director ensures uniform airflow and temperature distribution (FHY only) air flow distribution for ceiling heights up to 3.8m without loss of capacity
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit HxWxD H/L H/L H see page kW kW mm kg m3/min dB(A) dB(A) 35
FH35FJ7V1
4.05 1.3
FH45FJ7V1
5.35 2.11
FH60FJ7V1
6.5 2.42 30 18/14 40/35 56 R-FA7V1/W1
FH71FJ7V1
7.4 3.0(V1)/2.8(W1)
FH100FJ7V1 FH125FJ7V1
10.3 3.7(V1)/3.4(W1) 238x1,300x695 37 26/20 43/38 59 R-FJ7V1/W1 12.4 4.50 238x1,590x695 45 33/25 44/39 61 R-FJ7W1
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit HxWxD H/L H/L H see page kW kW mm kg m3/min dB(A) dB(A) 35
FH35GZ7V1
3.75 1.32
FH45GZ7V1
5.18 2.16/2.06
FH71GZ7V1
7.1 2.90/2.86/2.86 188x1,300x600 30 18/14 40/35 56 R-GZ7V1/W1/T1
FH100GZ7V1
9.7 3.69/3.47/3.47 238x1,300x695 37 26/20 43/38 59 R-GZ7V1/W1/T1
FH125GZ7V1
12.3 4.76 238x1,590x695 45 33/25 44/39 61 R-GZ7W1/T1
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit
22
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit cooling heating HxWxD H/L H/L H see page kW kW kW kW mm kg m3/min dB(A) dB(A) 36
FHY35GZ7V1
3.6 4.1 1.51 1.46
FHY45GZ7V1
4.9 5.5 2.04 1.91
FHY71GZ7V1
7.1 8.2 2.97(V1)/2.93(W1) 3.02(V1)/2.98(W1) 188x1,300x600 30 18/14 40/35 56 RY-GAZ7V1/W1
FHY100GZ7V1
10 11.2 4.04(V1)/3.84(W1) 4.02(V1)/3.85(W1) 238x1,300x695 37 26/20 43/38 59 RY-GAZ7V1/W1
FHY125GZ7V1
12.2 14.7 4.85 4.92 238x1,590x695 45 33/25 44/39 60 RY-GAZ7W1
23
optional
optional
optional
heat pump
optional
optional
heat pump
2 steps
2 steps
FHYK 35 ~ 71 p.43
FHK 35 ~ 60 p.40
4 - W AY B L O W C E I L I N G SUSPENDED CASSETTE
FUY-FJ
FH(Y)K-FJ
ideal for refurbishment leaves maximum floor and wall space for furniture, decoration air can be discharged in any of four directions air flow distribution for ceiling heights up to 3.5m no ceiling staining possibility to shut off one or two flaps for easy installation in corners extremely quiet in operation both indoor and outdoors air purification filter, drain pan and heat exchanger fin are mildew proof and have anti-bacterial treatment
perfect for applications in shops, restaurants or offices with false ceilings leaves maximum floor and wall space for furniture, decoration and fittings air flow distribution pattern can be adapted to suit ceiling heights up to 3.8 m without loss of capacity
COOLING ONLY
Cooling capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit unit decor. panel unit decor. panel H/L H/L H see page kW kW mm mm kg kg m3/min dB(A) dB(A) 35
FHK35FJV1
4.05 1.28 215x1,110x710 70x1,240x800 30 8.5 12/9 39/33 50 R-DC7V11
FHK45FJV1
5.35 2.11
FHK60FJV1
6.5 2.42
FHYK71FJV1
7.4 3.0(V1)/2.8(W1)
215x1,310x710 70x1,440x800 31 8.5 12/10 39/34 50 R-DC7V11/W11 33 9.5 17/14 41/36 52 R-FA7V1/W1 33 9.5 17/14 41/36 52 R-FJ7V1/W1
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz
FHYK35FJV1
kW cooling heating unit decor. panel unit decor. panel H/L H/L H see page kW kW kW mm mm kg kg m3/min dB(A) dB(A) 36 30 8.5 12/9 39/33 50 RY-DA7V1 4.1 4.35 1.5 1.39
FHYK45FJV1
4.8 5.8 2.05 1.90
FHYK60FJV1
6.15 7.15 2.51 2.4
FHYK71FJV1
7.3 8.7 3.1(V1)/3.0(W1) 3.1(V1)/3.0(W1)
FUY71FJV1
kW kW kW kW mm kg cooling/heating m3/min cooling dBA heating H see page dBA dBA 35/36 heating HxWxD 7.3 3.1/2.9 165x895x895 25 19/14 40/35 56 R-FJ7V1/W1
FUY100FJV1 FUY125FJV1
9.9 3.7/3.4 230x895x895 31 29/21 43/38 59 R-FJ7V1/W1 31 32/23 44/39 60 R-FJ7W1 12.3 4.5 -
FUY71FJV1
7.3 8.7 3.2/3.1 3.1/3.0 165x895x895 25 19/14 40/35 40/35 56 RY-FJ7V1/W1
FUY100FJV1 FUY125FJV1
10.0 12.2 4.0/3.8 3.8/3.6 230x895x895 31 29/21 43/38 43/38 59 RY-FJ7V1/W1 31 32/23 44/39 44/39 60 RY-FJ7W1 12.8 15.3 4.6 4.7
Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit
215x1,110x710 70x1,240x800 31 8.5 12/10 39/34 50 RY-DB7V1 33 9.5 17/14 41/36 52 RY-FA7V1
optional
optional
optional
heat pump
optional
optional
optional
FHYC 35 ~ 125
heat pump
2 steps
FHC35~60 p.40
2 steps
FHC35~60 p.40
4 - W AY B L O W C E I L I N G MOUNTED CASSETTE
FH(Y)C-BJ
FH(Y)C-BZ
4 - W AY B L O W C E I L I N G MOUNTED CASSETTE
fits flush into each ceiling air can be discharged in any of four directions possibility to shut off one or two flaps for easy installation in corners air flow distribution for ceiling heights up to 4.2m without loss of capacity
compact and lightweight unit with mimimum operating sound levels choice of 8 air flow distribution patterns air flow distribution for ceiling heights up to 4.2m without loss of capacity
COOLING ONLY
Cooling capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit unit decor. panel unit decor. panel H/L H/L H/L see page kW kW mm mm kg kg m3/min dB(A) dB(A) 35
FHC35BJV1
3.9 1.36
FHC45BJV1
5.2 2.15
FHC60BJV1
6.5 2.42
FHYC71BJV1
7.3 3.0(V1)/2.8(W1)
FHYC100BJV1 FHYC125BJV1
10.2 3.7(V1)/3.4(W1) 288x840x840 12.3 4.5
COOLING ONLY
Cooling capacity Nominal input Dimensions HxWxD unit decor. panel unit decor. panel H/L H/L H/L see page kW kW mm mm kg kg m3/min dBA dBA 35
FHC35BZV1
3.80 1.36
FHC45BZV1
5.2 2.20/2.10 230x840x840
FHYC71BZV1
7.1 2.99/2.96/2.96 40x950x950
FHYC100BZV1
10.0 3.77/3.56/3.56
FHYC125BZV1
12.3 4.76
230x840x840 40x950x950 23 5 14/10 31/27 47/43 R-DC7V11 23 5 15/11 31/27 47/43 R-DC7V11/W11 23 5 18/14 33/28 49/44 R-FA7V1/W1 23 5 18/14 33/28 49/44 R-FJ7V1/W1 27 5 28/21 37/32
288x840x840 23 5 18/14 33/28 49/44 R-GZ7V1/W1/T1 27 5 28/21 37/32 52/47 R-GZ7V1/W1/T1 27 5 31/24 40/35 55/50 R-GZ7W1/T1
Weight Air flow rate Sound press. level Sound power level Outdoor unit
52/47 R-FJ7V1/W1
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit
26
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound press. level Sound power level Outdoor unit cooling heating unit decor. panel unit decor. panel H/L H/L H/L see page kW kW kW kW mm mm kg kg m3/min dBA dBA 36
FHYC35BZV1
3.60 4.10 1.51 1.46
FHYC45BZV1
4.9 5.5 2.04 1.91 230x840x840 23 5 15/11 31/27 47/43 RY-EAZ7V1
FHYC71BZV1
7.1 8.2 3.0/2.96 2.97/2.93 40x950x950
FHYC100BZV1
10.0 11.6 4.11/3.89 4.03/3.86
FHYC125BZV1
12.2 14.6 4.89 4.99
288x840x840 23 5 18/14 33/28 49/44 RY-GZ7V1/W1 27 5 28/21 37/32 52/47 RY-GZ7V1/W1 27 5 31/24 40/35 55/50 RY-GZ7W1
27
optional
optional
heat pump
optional
optional
heat pump
FHB 35 ~ 60 p.40
2 steps
2 steps
FH(Y)B-FK
FH(Y)B-GZ
particularly suitable for restaurants, open-plan offices, apartments, entrance halls and irregularly shaped rooms movable air discharge grilles ensure uniform room temperatures the maximum external static pressure (ESP) is 9mmH2O
lightweight and compact blends unobtrusively with any interior decor extremely quiet in operation both indoors and outdoors the position of the individual air discharge grilles can be altered, enabling a uniform temperature, even in irregularly shaped rooms
COOLING ONLY
Cooling capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit unit decor. panel unit decor. panel H/L H/L H see page kW kW mm mm kg kg m3/min dB(A) dB(A) 35
COOLING ONLY
Cooling capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit unit decor. panel unit decor. panel H/L H/L H see page kW kW mm mm kg kg m3/min dB(A) dB(A) 35
FHB35GZ7V1
3.70 1.40
FHB45GZ7V1
4.90 2.23/2.13
FHYB71GZ7V1
7.1 2.96/2.93/2.93 300x1,000x800 55x1,100x500
FHYB100GZ7V1 FHYB125GZ7V1
10.0 3.70/3.54/3.54 300x1,400x800 55x1,500x500 51 6.5 27/20 36/31 62 R-GZ7V1/W1/T1 52 6.5 35/24 38/32 63 R-GZ7W1/T1 12.3 4.79
300x700x800 55x880x500 30 3.5 11.5/9.0 33/29 52 R-GZ7V11 31 3.5 14.0/10.0 33/29 53 R-GZ7V11/W11
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit
28
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit cooling heating unit decor. panel unit decor. panel H/L H/L H see page kW kW kW kW mm mm kg kg m3/min dB(A) dB(A) 36
FHYB35GZ7V1
3.60 4.10 1.64 1.46
FHYB45GZ7V1
4.9 5.5 2.09 1.97
FHYB71GZ7V1
7.1 8.2 2.97/2.93 3.03/2.96 300x1,000x800 55x1,100x500 41 4.5 19/14 34/30 60 RY-GZ7V1/W1
FHYB100GZ7V1 FHYB125GZ7V1
10.0 11.2 4.04/3.87 4.02/3.93 300x1,400x800 55x1,500x500 51 6.5 27/20 36/31 62 RY-GZ7V1/W1 52 6.5 35/24 38/32 63 RY-GZ7W1
29
300x700x800 55x880x500 30 3.5 11.5/9.0 33/29 52 RY-EAZ7V1 31 3.5 14.0/10.0 33/29 53 RY-EAZ7V1
optional
optional
optional
optional
optional
heat pump
2 steps
2 steps
FHYB-F
FAY-FJ
WA L L M O U N T E D U N I T
incorporates SUPER INVERTER technology achieves set temperature more quickly consumes up to 40% less energy than non-inverter models on an annual basis blends unobtrusively into any interior dcor particularly suitable for restaurants, open-plan offices, apartments, entrance halls and irregularly shaped rooms movable air discharge grilles ensure uniform room temperatures the maximum external static pressure (ESP) is 9mmH2O leaves maximum floor and wall space for furniture, decoration and fittings
designed to allow maximum use of floor space modern, space saving configuration even air distribution via automatic movable louvre that can also be fixed at any desired angle
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level H/L H/L H see page HxWxD kW kW mm kg m3/min dB(A) dB(A) 35
FAY71FJV1
7.4 3.1(V1)/2.9(W1) 360x1,570x200 26 19/16 41/37 57 R-FJ7V1/W1
FAY100FJV1
9.9 3.7(V1)/3.4(W1) 360x1,690x200 27 24/20 45/41 61 R-FJ7V1/W1
Outdoor unit
HEAT PUMP
Cooling capacity (1) Heating capacity (1) Nominal input (1) Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level Outdoor unit
30
FHYB71FV1
kW cooling heating unit decor. panel unit decor. panel H/L H/L H see page kW kW kW mm mm kg kg m3/min dB(A) dB(A) 38 5.7-7.1-8.0 5.4-8.0-9.0 3.5 3.3 300x1,000x800 55x1,100x500 41 4.5 19/14 42/36 * RZY71LV1
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit cooling heating HxWxD H/L H/L H see page kW kW kW kW mm kg m3/min dB(A) dB(A) 36
FAY71FJV1
7.3 8.3 3(V1)/2.9(W1) 3(V1)/2.9(W1) 360x1,570x200 26 19/16 42/38 57 RY-FJ7V1/W1
FAY100FJV1
10.3 12.0 3.8(V1)/3.6(W1) 4.1(V1)/3.9(W1) 360x1,690x200 27 24/20 45/41 61 RY-FJ7V1/W1
31
* Sound power levels were not available at the time of publication. (1) Units should be selected on nominal capacity. Maximum capacity is limited to peak periods.
optional
option
optional
FDY-F
UAT(Y)
PA C K A G E D U N I T S
extremely compact the maximum external static pressure (ESP) ranges from 15 till 25 mmH2O only air suction & discharge grilles are visible optimum air distribution
provides comfort conditions for large areas such as department stores or warehouses distributes supply and return air via ducts, ensuring optimum air distribution only inlet and discharge grilles are visible
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Air flow rate Sound pressure level Sound power level Outdoor unit HxWxD M M M see page kW kW mm kg m3/min dB(A) dB(A) 35
FDY125F7V1
12.4 5.1 350x1,400x662 57 45 44 78 R-FJ7W1
FDY200F7V1
20 8.1 450x1,400x900 84 72 45 83 R-F7W1
FDY250F7V1
24.2 9.4 86 90 47 83 R-F7W1
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Nominal air flow Sound pressure level Sound power level H/L H HxWxD kW kW mm kg m3/min dB(A) dB(A)
UAT12JY1
30.9 9.9 1,000x1,175x1,450 340 95 72 *
UAT22JAY1
59.3 21.2 1,300x1,965x1,760 660 200 80 *
UAT30HY1
97.1 31.4 1,755x2,860x1,340 1080 295 79 *
Refrigerant: R-22 Power supply: Y1: 3~, 400V, 50 Hz Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz
FDY125F7V1
kW kW cooling heating HxWxD M M M see page kW kW mm kg m3/min dB(A) dB(A) 36 12.4 13.4 5.1 4.5 350x1,400x662 57 45 44 78 RY-FJ7W1
FDY200F7V1
19.5 23.4 7.9 6.8 450x1,400x900 84 72 45 83 RY-F7W1
FDY250F7V1
25 27 9.4 8.1 86 90 47 83 RY-F7W1
Cooling capacity Heating capacity Nominal input Dimensions Weight Nominal air flow (indoor fan) Sound pressure level H/L Sound power level H
1,490x690x1,750 1,270x1,600x1,280 1,270x1,600x1,280 1,490x1,600x1,280 1,270x1,980x1,980 1,270x1,980x1,980 1,490x1,980x1,980 230 326 329 344 650 656 686 52 62 * 68 63 * 68 63 * 83 64 * 136 66 * 136 66 * 166 67 *
33
Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. They are fitted with either rotary or scroll compressor, renowned for low noise and high energy efficiency. A special acryl precoated fin for anti-corrosion treatment on the heat exchanger ensures greater resistance against severe weather conditions.
RE18-25-35-40 R25-35-45
R(E)
R60
R100/125
R200/250
PA I R A P P L I C AT I O N C O O L I N G O N LY
O utdoor units
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
R71FJ7V1/W1 R100FJ7V1/W1
860x830x320 77(V1)/74(W1) 48 62 -15~46 1,215x830x320 100(V1)/95(W1) 51 64 -15~46
R125FJ7W1
1,215x880x320 97 51 65 -15~46
R200F7W1
1,220x1,290x700 169 56 77 -5~46
R250F7W1
1,440x1,290x700 191 57 78 -5~46
Refrigerant: R-407C Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
R25GZ7V11
32 44 58 -15~46
REY18-22-35 RY22
RY200/250
RY100/125
RY60FA7
PA I R A P P L I C AT I O N H E AT P U M P
R(E)Y
RK-J/RX-J/RXT-JZ
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50Hz / W1: 3N~, 400V, 50Hz
Sound pressure level (H) cool./heat. Sound power level (H) cool./heat. Operation range cooling heating
Inverter Control: S TA R T- U P T I M E The use of integrated inverter control ensures REDUCED BY 1/3 maximum comfort and efficiency Short start up cycle Inverter control enables the required room temperature to be achieved quicker than with non inverter units, standard in fact, start up time is reduced by one third. heat pump system 30 % less power consumption The inverter controlled air conditioning detects changes small temperature difference in room or outdoor conditions and adjusts the indoor inverter heat pump system temperature to compensate within seconds. Rapid response reduces power consumption to 30% lower than that of non inverter systems. Whisper quiet Inverter controlled air conditioners, like all Daikin systems, are extremely quiet in operation. Only the extraordinary pleasure of the indoor environment betrays their existence. In case of RXT40-50G the use of the PAM (Pulse Amplitude Modulation) inverter technology results in better cooling and heating performances and lower energy consumption.
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50Hz / W1: 3N~, 400V, 50Hz
RY71FJ7V1/W1 RY100FJ7V1/W1
860x830x320 81/78 48/50 61 -5~46 -10~15 1,215x830x320 101/96 51/53 64 -5~46 -10~15
RY125FJ7W1
1,215x880x320 102 51/53 64 -5~46 -10~15
RY200F7W1
1,220x1,290x700 170 58/59 79/80 0~46 -10~15
RY250F7W1
1,440x1,290x700 195 58/59 79/80 0~46 -10~15
CO/HP
Dimensions Weight Sound pressure level (H) cool/heat Sound power level (H) cool/heat Standard oper. range cooling heating HxWxD mm kg dBA dBA CDB CWB
RK25JV1NB
33 46/59 10~46 -
RK35JV1NB
35 47/60 10~46 -
RX25JV1NB
33 46/47 59/60
550x695x265
550x695x265
10~46 -10~15
Refrigerant: R-407C Power supply: V1: 1~, 230V, 50Hz / W1: 3N~, 400V, 50Hz
RY35EAZ7V1
mm kg dBA dBA CDB CWB 660x880x350 50 46/48 59/60 -5~46 -10~15.5
RY45EAZ7V1
660x880x350 57 47/48 60/61 -5~46 -10~15.5
RY71GZ7V1/W1
860x830x320 81/78 50/52 62/-5~46 -10~15
RY100GZ7V1/W1
1,215x830x320 101/96 53/56 65/-5~46 -10~15
RY125GZ7W1
1,215x880x320 102 53/56 65/-5~46 -10~15
HEAT PUMP
Dimensions Weight HxWxD mm kg dBA dBA CDB CWB
RXT25JZV1NB RXT35JZV1NB
550x695x245 36 46/48 61/63 10~43 -10~15
37
HxWxD
Sound pressure level (H) cool/heat Sound power level (H) cool/heat Standard oper. range cooling heating
47/49 62/64
RZY
ER/ERC
ER
ERC
CONDENSING UNITS
increased comfort thanks to the air flow adjustment grille. The grille can be altered in 4 directions according to how it is installed the outdoor unit operates very quietly the outdoor unit can easily be mounted on a roof or terrace or placed against an outside wall possible indoor units are FHYB71FV1 (see p.30) and FHYC71BJV1 (see p.26)
Room temperatures fluctuate constantly, depending on the number of people present in an office or shop, or on the amount of office equipment in use at any one time. Besides these indoor fluctuations there are variations in day and night outdoor temperatures as well. The Super Inverter controlled unit closely monitors these variations and maintains the room temperature at the most comfortable level. In this way the Super Inverter drastically saves on power consumption creating an ideal climate in shops and offices.
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz / T1=3~,220V, 50Hz
ER5DAW1/T1
1,179x922x373 130 58 71 0~43 -15~43
ER8DAW1/T1
1,254x1,390x373 185 59 72 0~43 -15~43
ER10DAW1/T1
1,560x1,390x373 210 60 73 0~43 -15~43
Longer business hours mean longer operating periods for the air conditioning and in contrast with Super Inverter controlled equipment, this results in increased power consumption on non inverter units. The application of inverter technology reduces unit power consumption by keeping temperatures constant, thus additional business hours do not necessarily lead to higher costs.
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz
Dimensions Weight Sound pressure level Sound power level Standard oper. range Optional oper. range
Refrigerant: R-22 Power supply: T1: 3~, 220V, 50 Hz / W1: 3N~, 400V, 50 Hz
HEAT PUMP
Dimensions Weight HxWxD mm kg
RZY71LV1
860x830x320 91 51/53 * -5 ~ 50 -15 ~ 15.5
ERC
Dimensions Weight Sound pressure level Sound power level Standard oper. range Optional oper. range HxWxD mm kg dBA dBA CDB CDB
ERC3CBW1/T1
1,100x675x605 105 54 * 0~43 -10~43
ERC5CBW1/T1
1,345x795x605 160 58 * 0~43 -10~43
ERC8CBW1/T1
1,290x1,125x605 215 59 * 0~43 -10~43
ERC10CBW1/T1
1,395x1,275x605 250 60 * 0~43 -10~43
39
Sound pressure level(H) cooling/heating dB(A) Sound power level H dB(A) Operation range
38
cooling heating
CDB CWB
M U LT I M O D E L A P P L I C AT I O N - P O S S I B L E I N D O O R U N I T S
MA(E)/M(E)Y
M U LT I M O D E L A P P L I C AT I O N
Notes: Multi units are certified by Eurovent for combinations up to two indoor units.
18
X X
25
X X X X
35
X X X X X X X
40
X
45
X X X X X X X
60
X X X X X X
Refrigerant: R-22/R-407C Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
25
X X
35
X X X X
45
X X X X
COOLING ONLY
Max. nr. of indoor units Maximum capacity Maximum nominal input Dimensions Weight Sound pressure level Sound power level Operation range HxWxD H standard optional kW kW mm kg dBA dBA CDB CWB
18
X X
22
X X X X
35
X X X
40
X
45
X X X
60
X
(ambient temperature)
Refrigerant: R-22 Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
HEAT PUMP
Max. nr. of indoor units Maximum capacity cooling heating Maximum nominal input cooling heating Dimensions Weight Sound pressure level H/L Sound power level HxWxD cooling heating cooling heating cooling kW kW kW kW mm kg dBA dBA dBA dBA CDB CWB
MEY32GA7V1
2 3.95 3.8 1.38 1.06 660x880x350 50 46 47 58 60 20~43 -10~15.5
MY56DA7V1
3 5.8 5.95 2.19 2.25 660x880x350 72 46 49 59 62 -5~46 -10~15.5
MY90CJ7V1/W1
5 8.45 9.43 3.12 2.49 865x880x350 96/95 56 57 68 69/70 -5~46 -7~15.5
41
25
X X
35
X X
50
X X
60
X X
25
X X
35
X X
50
X X
60
X X Operation range
FTX CDX
Note: The power consumption mentioned in the table above is the TOTAL power consumption, i.e. based on the combination with FT(Y)...GV1B indoor unit(s).
M U LT I M O D E L A P P L I C AT I O N INVERTER CONTROLLED
2MX/3MX/4MX/4MK
OUTDOOR UNITS FOR TWIN, TRIPLE AND D O U B L E T W I N A P P L I C AT I O N
Multi model application, inverter controlled Wall mounted and concealed ceiling, inverter controlled units can be installed in multi model application. Combination with non-inverter indoor units is not possible. Multi inverter controlled outdoor units can be placed on top of each other*, thereby saving installation space. An optional fixing plate between the 2 outdoor units is necessary.
* 3MX68HV1NB/2MX52HV1NB units only
It is possible to connect 2,3 or 4 indoor units to a single outdoor unit. The indoor units may be of different types (e.g. ceiling mounted 4-way blow cassette, wall mounted, ...) and even different capacities (e.g. 45 and 60 class). All indoor units are operated together within the same mode (cooling or heating) from one remote control. This allows equal air distribution, even in larger, irregularly shaped rooms. For specifications of outdoor units, see pages 35 (cooling only) and 36 (heat pump). The total capacities (outdoor base) for simultaneous operation are the same as for the pair applications. example: R200 + FHY71 + FAY71 + FHYB71 = R200 + FDY200 = 20.0 kW
TWIN
out in in in
TRIPLE
out in in
DOUBLE TWIN
out in in in in
SYSTEM LAY-OUT
*
35
HP/CO
Max. nr. of indoor units Maximum capacity (min.-nom.-max.) (min.-nom.-max.) Dimensions Weight Sound pressure level H Sound power level cooling heating H cooling heating heating HxWxD kW kW kW kW mm kg dBA dBA dBA CDB CWB
2MX52HV1NB
2 3.60 ~ 5.20 ~ 5.34 4.56 ~ 6.10 ~ 7.80 1.09 ~ 2.10 ~ 2.30 1.20 ~ 1.74 ~ 2.57 660x790x330 61 45 46 * 21~43 -10~15
3MX68HV1NB
3 3.90 ~ 6.80 ~ 7.24 1.20 ~ 2.47 ~ 2.81 4.60 ~ 8.60 ~ 9.45 1.11 ~ 2.61 ~ 3.07 750x790x300 69 47 48 * 21~43 -10~15
4MX80HV1NB
4 4.37 ~ 8 ~ 9.13 5.83 ~ 9.6 ~ 10.63 1.29 ~ 2.59 ~ 3.76
4MK90HV1NB
4
71
71
OUTDOOR UNIT
35
(KHR79BA7)
100
*
45 45
100 60 35
100
*
71 35
100 35
*
35
45
(KHR79BA7)
125 60 60
(KHR79BA7)
125 45
(KHR79BA7)
(KHR86HA7)
125 45 45
*
71
*
45
(KHR79BA7)
200 100 100
(KHR79BA7)
200 71 125 71
(KHR86HA7)
200 71 71 60 200 60 60 45 200 71 71 45 200 45 100 45 200 45 45 45
(KHR102BA7)
250 125 125
(KHR102BA7)
(KHR127HA7)
250 45 100 100
(KHR127HA7)
250 60 60 125
(KHR127HA7)
(KHR127HA7)
(2xKHR79BA7+KHR102BA7)
250 60 60 60 60
(KHR102BA7)
(KHR127HA7)
(KHR127HA7)
(2xKHR79BA7+KHR102BA7)
Note 1 : Possible indoor types R-22: FHYC35-125 - FUY71-125 - FHYK35-71 - FAY71/100 - FHY35-60 - FHY71-125 - FH71-125 - FHYB35-125 - FDY125 Note 2 : Combinations marked with * are also available with the ozone-friendly refrigerant R-407C. Possible indoor types are FHYC - FHY - FHYB 35-71. Replace refnet kits with KHRP79BA7 and KHRP86HA7. Note 3 : Between brackets the required refnet kits are mentioned necessary to install the combination.
43
3
THE COMPLETE AIR CONDITIONING SYSTEM
Hi-VRV
Rising energy and general building services running costs have led end users to expect far more than just cooling and heating from their air conditioning. A truly complete and acceptable system therefore, must be energy efficient, economic to run, easy to install, flexible, reliable and user friendly. Fresh air must also be supplied without increasing energy consumption and central management and control facilities have gained in importance, particularly for medium to large sized buildings. The Daikin Hi-VRV system meets all these requirements:
Air Conditioning
VRV
HRV
DACMS
Ventilation
Management
VRV air conditioning can be found in offices, restaurants, theatres, hospitals, universities, museums, shops - in short, in any location where the provision of a balanced, pleasant working environment can improve the lifestyle and comfort of the individual.
45
VA R I A B L E R E F R I G E R A N T V O L U M E
VRV
Modular design enables Daikin VRV outdoor units to be joined together in rows with an outstanding degree of uniformity. The design of the outdoor units is sufficiently compact to allow them to be taken up to the top of a building in a commercial elevator, overcoming site transportation problems.
The VRV system is available in inverter driven cooling only, heat pump and heat recovery format, each designed to provide efficient and flexible comfort cooling and/or heating in a wide range of public and private commercial premises. An electronic expansion valve continually adjusts the flow of refrigerant to respond to the load requirements of the indoor units, enabling the system to maintain temperatures at a virtually constant and comfortable level without the fluctuations typical of ON/OFF control systems. The ability to control each conditioned zone keeps VRV system running costs to an absolute minimum. Furthermore, only those areas calling for air conditioning need to be cooled or heated and the system can be shut down completely in unoccupied rooms.
VRV Inverter series for either cooling or heating The system links up to 16 smart, stylish indoor units with a single outdoor unit, enabling cooling or heating to be supplied from the same refrigeration circuit. Inverter controlled
VRV heat recovery series for simultaneous cooling and heating The system combines 16 indoor units and one outdoor unit, with remarkable savings in energy consumption. Heat recovery is achieved by diverting exhaust heat from indoor units in cooling mode to those areas requiring heating.
Inverter controlled
Refrigerant: R-22/R-407C Power supply: Y1:3~, 400V, 50 Hz
RSEY8KLY1
22.4 25.0 9.43 8.48 1,220x1,280x690 250 150 57 -5 ~ 43 -15 ~ 15.5
RSEY10KLY1
28.0 31.5 11.8 10.5 1,440x1,280x690 275 170 57 -5 ~ 43 -15 ~ 15.5
RSEYP8KJY1
22.4 25.0 9.43 8.66 1,220x1,280x690 247 150 57 -5 ~ 43 -15 ~ 15.5
RSEYP10KJY1
28.0 31.5 11.8 11.0 1,440x1,280x690 273 170 57 -5 ~ 43 -15 ~ 15.5
47
cooling heating
New
main unit
sub unit
RSXYP20KJY1
VRV Plus using R-407C Available in heat pump format The latest addition to the VRV Plus series is the heat pump version using R-407C refrigerant. This new line-up from 16HP up to 30HP consists of 2 outdoor components, main & sub unit. Up to 32 indoor units can be connected to 1 single refrigerant circuit.
VRV Plus using R-22 Available in heat pump and heat recovery format. Daikin VRV PLUS is a high capacity system for installations between 16 and 30hp (3 times the standard VRV capacity) and is the first available refrigerant flow system able to operate as many as 30 indoor units on a single refrigerant circuit. The use of Daikin 'super wiring' reduces installation costs by integrating the control and communication wiring into a single circuit.
function unit constant speed type inverter type
RXY20K
Refrigerant: R-22 Power supply: W1: 3N~,400V, 50 Hz Inverter type Constant speed type
Power supply: V1: 1~, 230V, 50 Hz Function unit 27.4 1,280x400x690 80/64 -5 ~ 43 -15 ~ 15.5 1,280x500x690 96/76 -5 ~ 43 -15 ~ 15.5
RXY8K7W1
21.9 21.9 1,220x1,280x690 220 58 -5 ~ 43 -15 ~ 15.5
RXY10K7W1
27.4 27.4 1,440x1,280x690 240 58 -5 ~ 43 -15 ~ 15.5
RNY8K7W1
21.9 21.9 1,220x1,280x690 220 58 -5 ~ 43 -15 ~ 15.5
Cooling capacity Heating capacity Dimensions Weight Sound pressure level Operation range Refrigerant: R-407C Power supply: Y1:3~, 400V, 50 Hz cooling heating HxWxD
RSXYP28KJY1
RSXYP16KJY1
main unit sub unit RXEP8KJY1 43.8 43.8 15.7 14.2 1,440 1,280 690 360 320 60 -5 ~ 43 -15 ~ 15.5 1,220 1,280 690 95
RSXYP18KJY1
main unit RXYP10KJY1 49.3 49.3 18.1 15.5 1,440 1,280 690 365 320 60 -5 ~ 43 -15 ~ 15.5 1,220 1,280 690 95 sub unit RXEP8KJY1
RSXYP20KJY1
main unit RXYP10KJY1 54.7 54.7 20.2 16.9 1,440 1,280 690 365 340 60 -5 ~ 43 -15 ~ 15.5 1,440 1,280 690 105 sub unit RXEP10KJY1
RXYP8KJY1
RXY16K
16 43.8 43.8 16.5 13.5 200-520 1 1 1
RXY18K
18 49.3 49.3 19.1 14.8 225-585 1
RXY20K
20 54.7 54.7 21.3 16.1 250-650 1
RXY24K
24 65.7 65.7 26.3 20.4 300-780 1 1
RXY26K
26 71.2 71.2 28.3 20.9 325-845 1 1 2
RXY28K
28 76.1 76.1 30.2 22.8 350-910 1 1 1 1
RXY30K
30 82.1 82.1 32.8 25.8 375-975 1 1 2
Indoor Unit Connectable Capacity Function unit heat pump (L Unit) Function unit heat pump (L Unit) Inverter outdoor unit Inverter outdoor unit Constant speed type outdoor unit Constant speed type outdoor unit
1 1
1 2 1
RSXYP24KJY1
main unit sub unit RXEP8KJY1 65.7 65.7 25.0 21.4 1,450 2,580 690 620 490 62 -5 ~ 43 -15 ~ 15.5 1,220 1,280 690 95
RSXYP26KJY1
main unit sub unit RXYP16KJY1 RXEP10KJY1 71.2 71.2 26.9 21.9 1,450 2,580 690 620 510 62 -5 ~ 43 -15 ~ 15.5 1,440 1,280 690 105
RSXYP28KJY1
main unit sub unit RXYP20KJY1 RXEP8KJY1 76.1 76.1 28.7 23.9 1,450 2,580 690 630 490 62 -5 ~ 43 -15 ~ 15.5 1,220 1,280 690 95
RSXYP30KJY1
main unit sub unit RXYP20KJY1 RXEP10KJY1 82.1 82.1 31.2 27.1 1,450 2,580 690 630 510 62 -5 ~ 43 -15 ~ 15.5
49
RXYP16KJY1
HEAT RECOVERY
Equivalent HP Cooling Capacity Heating Capacity Nominal input cooling HP kW kW kW kW BR2KJV1 BR3KJV1 RXY8K7W1 RXY10K7W1 RNY8K7W1 RNY10K7W1
REY16K
16 43.8 43.8 16.5 13.5 200-520 1 1
REY18K
18 49.3 49.3 19.1 14.8 225-585 1
REY20K
20 54.7 54.7 21.3 16.1 250-650 1
REY24K
24 65.7 65.7 26.3 20.4 300-780 1 1
REY26K
26 71.2 71.2 28.3 20.9 325-845 1 1
REY28K
28 76.1 76.1 30.2 22.8 350-910 1 1 1 1
REY30K
30 82.1 82.1 32.8 25.8 375-975 1 1 2
heating Indoor Unit Connectable Capacity Function unit heat rec. (R Unit) Function unit heat rec. (R Unit) Inverter outdoor unit Inverter outdoor unit Constant speed type outdoor unit Constant speed type outdoor unit
1 1 1
1 2 1
VRV indoor units, available in 10 different models and 60 different size combinations (58 combinations with ozonefriendly refrigerant R-407C), can meet virtually any site installation requirement.
optional
optional
FXYC
optional
Indoor units
FXYF(P) 4-way blow ceiling mounted cassette FXYC(P) 2-way blow ceiling mounted cassette
Refrigerant: R-22 Power supply: V1: 1~, 50Hz, 230V Refrigerant: R-22 Power supply: V1: 1~, 50Hz, 230V
FXYC-K7V1 FXYF-K7V1
Inverter CO/HP Heat recovery VRV Plus Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling heating unit decor. panel unit decor. panel H/L H/L W W mm mm kg kg m3/min dBA 25 6.5 10/7.8 31/29 25 6.5 10/7.8 31/29
20
cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling W heating W mm mm kg kg m3/min dBA 26 8 7/5 33/25 unit decor. panel unit decor. panel H/L H/L 2.2 2.5 2.2 2.2 77 44
25
2.8 3.2 2.7 2.7 92 59 305x780x600 53x1,030x680 26 8 9/6.5 35/30
32
3.6 4.0 3.4 3.4 92 59
40
4.5 5.0 4.4 4.4 130 97
50
5.6 6.3 5.5 5.5 130 97
63
7.1 8.0 6.8 6.8 153 120 305x1,180x600 53x1,430x680 35 9.5 15/12 36/31
80
9.0 10.0 8.8 8.8 209 176
125
14.0 16.0 13.7 13.7 256 223
20
2.2 2.5 2.2 2.2 140 107
25
2.8 3.2 2.7 2.7 140 107
32
3.6 4.0 3.4 3.4 140 107
40
4.5 5.0 4.4 4.4 140 107
50
5.6 6.3 5.5 5.5 140 107
63
7.1 8.0 6.8 6.8 161 128
80
9.0 10.0 8.8 8.8 204 171
100
11.2 12.5 10.9 10.9 204 171 280x1,230x840 50x1,340x950 34 9.5 28/19 40/34
125
14.0 16.0 13.7 13.7 238 205
Inverter CO/HP Heat recovery VRV Plus Nominal input Dimensions (HxWxD) Weight
240x840x840 50x950x950 25 25 6.5 13/10 35/30 6.5 14/10 35/30 25 6.5 16/11 36/31 25 6.5 19/14 37/32 34 9.5 28/19 40/34
305x995x600 53x1,245x680 26 8 9/6.5 35/30 31 8.5 12/9 36/30 32 8.5 12/9 36/30
Refrigerant: R-407C Power supply: V1: 1~, 50Hz, 230V Refrigerant: R-407C Power supply: VE: 1~, 50Hz, 230V
FXYCP-K7V1 FXYFP-KVE
Inverter CO/HP Heat recovery VRV Plus (1) Nominal input (1) Dimensions (HxWxD) Weight Air flow rate Sound pressure level
50
20
2.2 2.5 2.2 2.5 77 44
25
2.8 3.2 2.8 3.2 92 59 305x780x600 53x1,030x680 26 8 9/6.5 35/29 50
32
3.6 4.0 3.6 4.0 92 59
40
4.5 5.0 4.5 5.0 130
50
5.6 6.3 5.6 6.3 130
63
7.1 8.0 7.1 8.0 161 126 305x1,180x600 53x1,430x680 35 9.5 16.5/13 38/33 52
80
9.0 10.0 9.0 10.0 209
125
14.0 16.0 14.0 16.0 256
32
cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling W heating unit decor. panel unit decor. panel H/L H/L (220V) W mm mm kg kg m3/min dBA 24 5 13/10 30/27 3.6 4.0 3.6 4.0 158 120
40
4.5 5.0 4.5 5.0 158 120 230x840x840
50
5.6 6.3 5.6 6.3 158 120
63
7.1 8.0 7.1 8.0 178 140 40x950x950
80
9.0 10.0 9.0 10.0 178 140
100
11.2 12.5 11.2 12.5 238 200 288x840x840
125
14.0 16.0 14.0 16.0 278 240
Inverter CO/HP Heat recovery VRV Plus (1) Nominal input (1) Dimensions (HxWxD) Weight
cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling heating unit decor. panel unit decor. panel H/L H/L W W mm mm kg kg m3/min dBA dBA
24 5 14/10 31/27
24 5 16/11 32/27
24 5 18/14 33/28
28 5 28/20 37/31
28 5 28/21 39/32
28 5 33/24 44/35 Air flow rate Sound pressure level Sound power level
26 8 7/5 33/28 45
26 8 9/6.5 35/29 50
FXYK-KJV1/FXYKP-KV1
Inverter CO/HP Heat recovery VRV Plus (1) Nominal input (1) Dimensions (HxWxD) Weight Air flow rate Sound pressure level cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling W heating unit decor. panel unit decor. panel H/L H/L W mm mm kg kg m3/min dBA
25
2.8 3.2 2.7 2.7 66 46
32
3.6 4.0 3.4 3.4 66 46 215x1,110x710 70x1,240x800
40
4.5 5.0 4.4 4.4 80 56
63
7.1 8.0 6.8 6.8 105 85 215x1,310x710 70x1,440x800
25
2.8 3.2 2.8 3.2 66 46
32
3.6 4.0 3.6 4.0 66 46 215x1,110x710 70x1,240x800
40
4.5 5.0 4.5 5.0 80 56
63
7.1 8.0 7.1 8.0 105 85 215x1,310x710 70x1,440x800
Refrigerant: R-22 Power supply: V1: 1~, 50Hz, 230V/VE: 1~, 50Hz, 230V
FXYM-KJV1/VE*
Inverter CO/HP Heat recovery VRV Plus Nominal input Dimensions Weight Air flow rate Sound pressure level H/L H/L (220V) cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling heating HxWxD W W mm kg m3/min dBA
40
4.5 5.0 4.4 4.4 211 211 44 14/11.5 39/35
50
5.6 6.3 5.5 5.5 211 211 390x720x690 44 14/11.5 39/35
63
7.1 8.0 6.8 6.8 284 284 45 18/15 41/37
80
9.0 10.0 8.8 8.8 411 411 62 29/23 43/39
100
11.2 12.5 10.9 10.9 411 411 390x1,110x690 63 29/23 43/39
125
14.0 16.0 13.7 13.7 619 619 65 36/29 45/42
200*
22.4 25.0 22.4 25.0 1,294
250*
28.0 31.5 28.0 31.5 1,465
1,294 1,465 470x1,380x1,100 137 58/50 48/45 137 72/62 48/45 Refrigerant: R-22 / R407-C Power supply: V1: 1~, 50Hz, 230V
FXYB(P) concealed ceiling unit (small)
FXYB-K7V1/FXYBP-K7V1 FXYMP-KV1
Inverter CO/HP Heat recovery VRV Plus (1) Nominal input (1) Dimensions Weight Air flow rate Sound pressure level
52
20
2.2 2.5 2.2 2.2 50 50 230x652x502 17 6.7/5.2 37/32 -
25
2.8 3.2 2.7 2.7 50 50 17 7.4/5.8 37/32 -
20
2.2 2.5 2.2 2.5 50 50 230x652x502 17 6.7/5.2 37/32 50
25
2.8 3.2 2.8 3.2 50 50 17 7.4/5.8 37/32 50
53
40
4.5 5.0 4.5 5.0 211 211 44 14/11.5 39/35
50
5.6 6.3 5.6 6.3 211 211 390x720x690 44 14/11.5 39/35
63
7.1 8.0 7.1 8.0 281 281 45 19.5/16 42/38
80
9.0 10.0 9.0 10.0 411 411 62 29/23 43/39
100
11.2 12.5 11.2 12.5 411 411 390x1,110x690 63 29/23 43/39
125
14.0 16.0 14.0 16.0 619 619 65 36/29 45/42
200
22.4 25.0 22.4 25.0 1,294 1,294 137 58/50 48/45
250
28.0 31.5 28.0 31.5 1,465 1,465 137 72/62 48/45
cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling heating HxWxD H/L H/L (220V) W W mm kg m3/min dBA
Inverter CO/HP Heat recovery VRV Plus (1) Nominal input (1) Dimensions Weight Air flow rate Sound pressure level Sound power level
cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling W heating HxWxD H/L H/L W mm kg m3/min dBA dBA
470x1,380x1,100
FXYA-KJV1/FXYAP-KV1
Inverter CO/HP Heat recovery VRV Plus (1) Nominal input (1) Dimensions Weight Air flow rate Sound pressure level cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling W heating HxWxD H/L H/L W mm kg m3/min dBA
25
2.8 3.2 2.7 2.7 26 26
32
3.6 4.0 3.4 3.4 28 28 360x1,050x200 21
40
4.5 5.0 4.4 4.4 36 36
50
5.6 6.3 5.5 5.5 35 35
63
7.1 8.0 6.8 6.8 44 44
25
2.8 3.2 2.8 3.2 26 26
32
3.6 4.0 3.6 4.0 28 28 360x1,050x200 21
40
4.5 5.0 4.5 5.0 36 36
50
5.6 6.3 5.6 6.3 35 35
63
7.1 8.0 7.1 8.0 44 44
7/6 34/31
8/6.5 35/32
9/7 37/33
FXYS-KA7V1
Inverter CO/HP Heat recovery VRV Plus Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling W heating unit decor. panel unit decor. panel H/L H/L W mm mm kg kg m3/min dBA
20
2.2 2.5 2.2 2.2 110 90
25
2.8 3.2 2.7 2.7 110 90 300x550x800 55x650x500
32
3.6 4.0 3.4 3.4 110 90
40
4.5 5.0 4.4 4.4 127 107
50
5.6 6.3 5.5 5.5 140 120
63
7.1 8.0 6.8 6.8 184 164 300x1,000x800 55x1,100x500 41 4.5 19/14 34/30
80
9.0 10.0 8.8 8.8 216 196
100
11.2 12.5 10.9 10.9 216 196 300x1,400x800 55x1,500x500
125
14.0 16.0 13.7 13.7 290 270
300x700x800 55x800x500 30 3 9/6.5 32/28 30 3.5 11.5/9 33/29 31 3.5 14/10 33/29
30 3 9/6.5 32/28
30 3 9/6.5 32/28
FXYSP-KA7V1
Inverter CO/HP Heat recovery VRV Plus (1) Nominal input (1) Dimensions (HxWxD) Weight Air flow rate Sound pressure level Sound power level
54
20
2.2 2.5 2.2 2.5 110 90
25
2.8 3.2 2.8 3.2 110 90 300x550x800 55x650x500
32
3.6 4.0 3.6 4.0 114 94
40
4.5 5.0 4.5 5.0 127 107
50
5.6 6.3 5.6 6.3 143 123
63
7.1 8.0 7.1 8.0 189 169 300x1,000x800 55x1,100x500 41 4.5 21/15.5 35/30 56
80
9.0 10.0 9.0 10.0 216 196
100
11.2 12.5 11.2 12.5 246 226 300x1,400x800 55x1,500x500
125
14.0 16.0 14.0 16.0 321 301 Nominal input (1) 52 6.5 38/28 40/35 65 Dimensions Weight Air flow rate Sound pressure level Sound power level H/L H/L
cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling W heating unit decor. panel unit decor. panel H/L H/L W mm mm kg kg m3/min dBA dBA
FXYH-K7V1/FXYHP-K7V1
Inverter CO/HP Heat recovery VRV Plus (1) cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling heating HxWxD W W mm kg m3/min dBA dBA
32
3.6 4.0 3.4 3.4 101 101 188x1,100x600 27 13/10 38/33 -
63
7.1 8.0 6.8 6.8 114 114 188x1,300x600 31 18/14 40/35 -
100
11.2 12.5 10.9 10.9 190 190 238x1,300x695 38 26/20 43/38 -
32
3.6 4.0 3.6 4.0 101 101 188x1,100x600 27 13/10 38/33 56
63
7.1 8.0 7.1 8.0 114 114 188x1,300x600 31 19/15 42/37 61
100
11.2 12.5 11.2 12.5 190 190 238x1,300x695 38 27/21 45/40 63
55
300x700x800 55x800x500 30 3 9.5/7 33/28 51 30 3.5 11.5/9 33/29 56 31 3.5 15/11 35/31 58
30 3 9/6.5 32/28 50
30 3 9/6.5 32/28 50
Refrigerant: R-22/R-407C Power supply: VE: 1~, 50Hz, 230V/V1: 1~, 50Hz, 230V
FXYLM-KJVE/FXYLMP-KV1
Inverter CO/HP Heat recovery VRV Plus (1) R-22/R-407C Nominal input (1) Dimensions Weight Air flow rate Sound pressure level cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling W heating HxWxD H/L H/L (220V) W mm kg m3/min dBA
20
2.2 2.5 2.2/2.2 2.2/2.5 49 49 610x930x220 19 7/6 35/32
25
2.8 3.2 2.7/2.8 2.7/3.2 49 49 19 7/6 35/32
32
3.6 4.0 3.4/3.6 3.4/4.0 90 90 610x1,070x220 23 8/6 35/32
40
4.5 5.0 4.4/4.5 4.4/5.0 90 90 23 11/8.5 38/33
50
5.6 6.3 5.5/5.6 5.5/6.3 110 110 610x1,350x220 27 14/11 39/34
63
7.1 8.0 6.8/7.1 6.8/8.0 110 110 27 16/12 40/35
New
HRV
Clean outdoor air Total heat exchanged foul air
H E AT R E C O V E RY V E N T I L AT I O N
FXYL-KJVE
Inverter CO/HP Heat recovery VRV Plus Nominal input Dimensions Weight Air flow rate Sound pressure level cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling heating HxWxD H/L H/L (220V) W W mm kg m3/min dBA
20
2.2 2.5 2.2 2.2 49 49 600x1,000x222 25 7/6 35/32
25
2.8 3.2 2.7 2.7 49 49 25 7/6 35/32
32
3.6 4.0 3.4 3.4 90 90 600x1,140x222 30 8/6 35/32
40
4.5 5.0 4.4 4.4 90 90 30 11/8.5 38/33
50
5.6 6.3 5.5 5.5 110 110 600x1,420x222 36 14/11 39/34
63
7.1 8.0 6.8 6.8 110 110 36 16/12 40/35
The Daikin heat recovery ventilation system modulates the temperature and humidity of incoming fresh air to match indoor conditions. A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or heating load placed on the air conditioning system to be reduced significantly. HRV units can be controlled individually or integral with the air conditioning system (Daikin VRV or Sky Air series).
Power supply: VE: 1~, 50Hz, 230V Refrigerant: R-407C Power supply: V1: 1~, 50Hz, 230V
FXYLP-KV1
Inverter CO/HP Heat recovery VRV Plus (1) Nominal input (1) Dimensions Weight Air flow rate Sound pressure level
56
20
cooling capacity kW heating capacity kW cooling capacity kW heating capacity kW cooling heating HxWxD H/L H/L (220V) W W mm kg m3/min dBA 25 7/6 35/32 2.2 2.5 2.2 2.5 49 49 600x1,000x222
25
2.8 3.2 2.8 3.2 49 49 25 7/6 35/32
32
3.6 4.0 3.6 4.0 90 90 600x1,140x222 30 8/6 35/32
40
4.5 5.0 4.5 5.0 90 90 30 11/8.5 38/33
50
5.6 6.3 5.6 6.3 110 110 600x1,420x222 36 14/11 39/34
63
7.1 8.0 7.1 8.0 110 110 36 16/12 40/35
VAM-FJVE
Air flow rate Sound pressure level (max.) (1) External static pressure (max.) Temperature exchange efficiency Enthalpy exchange efficiency (%) Dimensions H W D Weight Duct diameter m3/h dBA Pa % cooling heating mm mm mm kg mm
150
150 27/28.5 69 74 58 64 269 760 509 24 100
250
250 28/29 64 72 58 64 269 760 509 24 150
350
350 32/34 98 75 61 65 285 812 800 33 150
500
500 33/34.5 98 74 58 62 285 812 800 33 200
650
650 34.5/35.5 93 74 58 63 348 988 852 48 200
800
800 36/37 137 74 60 65 348 988 852 48 250
1000
1,000 36/37 157 75 61 66 348 988 1,140 61 250
1500
1,500 39.5/41.5 137 75 61 66 710 1,498 852 132 350
2000
2,000 40/42.5 137 75 61 66 710 1,498 1,140 158 350
57
DACMS is a centralized control and management system for medium and large sized buildings. Designed for use with Windows95, Windows98 and WindowsNT it offers precise control of VRV systems and associated heat recovery ventilation units, fans and even lighting, from a personal computer and can monitor up to 1,024 indoor units from a single PC.
New
DACMS
Hi-VRV
SELECTION PROGRAMME
DACMS can be integrated into a general building management system, both to control the air conditioning (monitoring energy consumption, indoor temperatures etc) and also to provide a wide range of custom designed management and service functions. It can, for example, be used to limit energy consumption, indicate filter replacement needs or calculate optimum start up periods.
Windows95, Windows98 and WindowsNT are registered trademarks of Microsoft corporation.
A simple to use, Daikin Hi-VRV air conditioning computerised selection programme, designed for use with Windows95, Windows98 and WindowsNT systems, enables consulting engineers, design and build contractors, property developers and architects etc. to plan a Daikin air conditioning project on a step by step basis, complete with detailed drawings, bills of quantities and costs. The programme thus enables VRV air conditioning systems to be engineered precisely and economically (without oversizing units), thereby ensuring optimum operating cycles and maximum energy efficiency.
Windows95, Windows98 and WindowsNT are registered trademarks of Microsoft corporation.
58
59
4
POWER & PRECISION
H ydronic systems
Precise environmental control is vital in many industrial and commercial applications. Daikin offers an outstanding range of powerful air cooled, water cooled and condenserless chiller systems that will maintain ideal conditions in even the largest premises. Daikin water chillers are of advanced design, compact and easy to install and maintain. They prove flexible and effective in multiple process cooling applications in for example, fish farms, wine cellars, maritime transport, agricultural, pharmaceutical or industrial processes. When combined with air handling units or Daikin fan coil units of course, they are ideal for air conditioning offices, hotels, restaurants and even domestic premises. Matched and flexible equipment/refrigerant combinations enable Daikin to offer a complete range of chillers, genuinely optimised for use with R-134a and R-407C and possessing the same quality and performance levels as comparable R-22 models. All chiller components -evaporator, condenser, dryer, oil etc - have been specially selected for use with either R-407C or R-134a refrigerants. The end result is a range of hi tech, high performance units, indicated by published EUROVENT data to be among the most energy efficient of their type on the market. Advanced technology allied unsurpassed product reliability and quality, make Daikin chillers the first choice for professionals.
61
CHILLERS
air cooled
EUWA/Y
EUWA-HZ
CHILLERS
air cooled
low operating sound level low energy consumption extremely compact Daikin scroll compressor electronic controller wide operating range easy to install and maintain anti-corrosion treated plate type heat exchangers available in cooling only (EUWA) and heat pump format (EUWY)
optimised for use with R-407C special Daikin R-407C scroll compressors high energy efficiency ratio low pressure drops low sound level low direct on line start up current small footprint standard operating range from -5C to 43C ambient temperature
Refrigerant : R-22 Power supply: W1 = 3N~, 50Hz, 400V; T1 = 3~, 50Hz, 230V.
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Sound power/pressure level HxWxD kW kW mm kg dB(A)
Refrigerant : R-407C Power supply: W1 = 3N~, 50Hz, 400V; T1 = 3~, 50Hz, 230V. (except for 12HP)
COOLING ONLY
Cooling capacity Nominal input Dimensions HxWxD Weight Sound power/pressure level kW kW mm kg dB(A)
EUWA5HDZ
10.1 4.2 1,444x645x700 135 69/56
EUWA8HDZ
17.7 7.2 1,220x1,290x700 200 78/61
EUWA10HDZ
22.7 8.5 1,444x1,290x700 230 78/61
EUWA12HDZ
26.5 10.6 1,444x1,290x700 233 78/61
HEAT PUMP
Cooling capacity Heating capacity Nominal input Dimensions Weight Sound power/pressure level
62
Refrigerant : R-407C Power supply: W1 = 3N~, 50Hz, 400V; T1 = 3~, 50Hz, 230V. (except for 25,35HP)
COOLING ONLY
Cooling capacity Nominal input Dimensions HxWxD Weight Sound power/pressure level kW kW mm kg dB(A)
EUWA15HDZ
32.8 12.7 1,535x1,930x700 375 78/62
EUWA20HDZ
45.4 17.0 1,535x2,575x700 510 81/64
EUWA25HDZ
53.0 21.2 1,535x2,575x700 510 81/64
EUWA30HDZ
68.1 25.5 1,535x3,865x700 780 83/67
EUWA35HDZ
79.5 31.8 1,535x3,865x700 780 83/67
63
CHILLERS
air cooled
EUWA*
EUWA*-KX
EUWA* 40 - 60 KAX
CHILLERS
air cooled
low operating sound level single screw compressor high energy efficiency ratio operating range from -15C to 43C available in 6 models with nominal cooling capacities from 101 to 300 kW units with special pressure vessel approval are available on request
EUWA* 40 - 60 KA
optimised for use with R-134a special Daikin single screw compressor high EER low noise option available BMS connection possible evaporators located in the middle of the unit 2 switchboxes (high and low voltage) new compressor housing victaulic joints for plate heat exchangers pre mounted 5 inch piping for easier field piping operations (from 160hp on)
Refrigerant : R-134a Power supply: Y1 = 3~, 50Hz, 400V; T1 = 3~, 50Hz, 230V (only EUWA*40-120K(A)X)
COOLING ONLY
Cooling capacity Nominal input kW kW HxWxD mm kg dB(A)
EUWA*40KAX
111 39.1 1,391 91/-
EUWA*50KAX
140 53.7 2,135x3,980x1,110 1,600 97/-
EUWA*60KAX
166 64 1,705 95/-
EUWA*80KAX
211 79
EUWA*100KAX
276 110
EUWA* 80 - 120 KA
Dimensions
Weight Sound power/pressure level Refrigerant : R-22 Power supply: Y1: 3~, 50 Hz, 400V / T1: 3~, 50Hz, 230V
Refrigerant : R-134a Power supply: Y1 = 3~, 50Hz, 400V; T1 = 3~, 50Hz, 230V (only EUWA*40-120K(A)X)
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight HxWxD kW kW mm kg dB(A)
EUWA*40KA
101 38.5 1,205 88/-
EUWA*50KA
129 52.7 2,135x3,980x1,110 1,345 92/-
EUWA*60KA
161 59.0 1,530 94/-
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight Sound power/pressure level HxWxD kW kW mm kg dB(A)
EUWA*120KAX
316 130 2,156x3,980x2,210 3,260 98/-
EUWA*160KX
400 164 5,400 99/-
EUWA*180KX
438 178 2,156x5,906x2,265 5,450 100/-
EUWA*200KX
475 191 5,500 100/65
* =T(Germany - TV), K(Finland - TTK), M(France - SdM), B(Italy - ISPESL), Q(Poland-UDT), D(The Netherlands - RLK law), S(Sweden - AB-Staten) according to corresponding pressure vessel approval.
* =T(Germany - TV), K(Finland - TTK), M(France - SdM), B(Italy - ISPESL), Q(Poland-UDT), D(The Netherlands - RLK law), S(Sweden - AB-Staten) according to corresponding pressure vessel approval.
CHILLERS
air cooled
EUWA*-LZ
EUWAC
CHILLERS
air cooled
Daikin single screw compressor all components optimised for use with R-407C refrigerant electronic DDC control modular format standard operating range down to -15C ambient high quality, standard anti-corrosion treated components moisture indicator as standard victaulic joints as standard chilled water temperatures down to 4C (down to -10C with ZL option and glycol) optional BMS and DICN connection available double refrigeration circuits (from 160hp on) pre-mounted, 5 inch piping for easier field connection
EUWA*40 - 60LZ
EUWA*80 - 120LZ
Refrigerant : R-407C Power supply: Y1 = 3~, 50Hz, 400V
centrifugal fan cooling only application nom. cooling capacities ranging from 11.5 to 23.0 kW available in 3 standard sizes specially designed for inside installation
COOLING ONLY
Cooling capacity Nominal input Dimensions HxWxD Weight Sound power/pressure level kW kW mm kg dB(A)
EUWA*60LZ
155 66 1,637 96/-
EUWA*80LZ (1)
205 87
EUWA*100LZ (1)
269 112
2,165x4,280x2,238 2,833 95/3,152 96/Refrigerant : R-22 Power supply: W1 = 3N~, 50Hz, 380/415V; T1 = 3~, 50Hz, 220V. Refrigerant : R-407C Power supply: Y1 = 3~, 50Hz, 400V
EUWAC5FA
kW kW mmH2O mm kg dB(A) 11.5 5.2 10 1,345x795x605 175 -/53
EUWAC8FA
18.8 9.0 15 1,290x1,125x605 230 -/59
EUWAC10FA
23.0 11.1 15 1,395x1,175x605 270 -/60
67
EUWA*120LZ (1)
kW 310 135 2,165x4,280x2,238 3,404 97/kW mm kg dB(A)
EUWA*160LZ
419 171 5,002 100/-
EUWA*180LZ
479 202 2,165x5,906x2,238 5,044 101/-
EUWA*200LZ
539 232 5,086 102/-
Cooling capacity Nominal input Maximum external static pressure Dimensions HxWxD Weight Sound power/pressure level
HxWxD
* =T (Germany - TV), K(Finland - TTK), M(France - SdM), B(Italy - ISPESL), Q(Poland - UDT), D(The Netherlands - RLK law), S(Sweden - AB-Staten) according to corresponding pressure vessel approval. / (1) Preliminary info
EUWL*40-100KX
CHILLERS CHILLERS
water cooled
EUW(H)
EUW(L)*-KX
the most compact unit in the market optimised design for use with R-134a special Daikin screw compressor high EER electronic controller control on cold and hot side voltage free contacts (for alarms etc) LWE control lead lag switch victaulic joints as standard totally independent twin circuits (from 120hp on) condenserless units available throughout the range
EUW*120-200KX
Refrigerant : R-134a Power supply: T1 = 3~, 50Hz, 230V/ Y1 = 3~, 50Hz, 4000V
EUW(L)*40KX
Cooling capacity (EUW) kW kW kW kW kW kW mm kg kg dB(A) 120 119 149 30.0 30.5 35.1 990 882 90/-
EUW(L)*60KX
190 188 237 48.6 49.4 57.2
EUW(L)*80KX
249 246 313 66.1 67.2 75.5
EUW(L)*100KX
290 287 362 74.0 75.3 87.3 1,680 1,410 98/-
for indoor (or outdoor) installation available in cooling only (EUW) and heating only (EUWH) models units with special pressure vessel approval are available on request hermetic reciprocating compressor
Cooling capacity (EUWL) Heating capacity (EUW) Power input (EUW) Cooling Power input (EUWL) Power input (EUW) Dimensions Weight (EUW) Weight (EUWL) Sound power/pressure level Cooling Heating HxWxD
Refrigerant : R-134a Power supply: T1= 3~,50Hz, 230V / Y1 = 3~, 50Hz, 400V
Refrigerant : R-22 Power supply: T1=3~, 50Hz, 230V ; Y1 = 3~, 50Hz, 400V
EUW(L)*120KX
Cooling capacity (EUW) Cooling capacity (EUWL) Heating capacity (EUW) Power input (EUW) Power input (EUWL) Power input (EUW) Dimensions Weight (EUW) Weight (EUWL) Sound power/pressure level Cooling Cooling Heating HxWxD kW kW kW kW kW kW mm kg kg dB(A) 380 376 474 97.2 98.9 114 2,640 2,200 99/-
EUW(L)*140KX
439 434 551 115 117 133 2,960 2,470 99/-
EUW(L)*160KX
498 493 626 132 134 151 2,000x2,672x898 3,280 2,740 99/-
EUW(L)*180KX
539 533 675 140 143 163 3,320 2,780 100/-
EUW(L)*200KX
580 574 724 148 151 175 3,360 2,820 101/69
EUW(H)5FB
kW kW cooling heating HxWxD kW kW mm kg dB(A) 13.2 16.1 3.9 4.4 700x904x604 150 -/50
EUW(H)8FA
20.4 24.2 5.8 6.5 800x1,104x754 200 -/51
EUW(H)10FA
26.8 32.0 7.6 8.5 800x1,104x754 215 -/51
EUW(H)15F
49.4 56.6 12.3 13.6 1,155x1,092x448 285 -/56
EUW(H)20F
59.6 68.9 15.3 16.9 1,155x1,092x448 306 -/59
* =T(Germany - TV), K(Finland - TTK), M(France - SdM), B(Italy - ISPESL), Q(Poland-UDT), D(The Netherlands - RLK law), S(Sweden - AB-Staten) according to corresponding pressure vessel approval.
D.I.C.N
models R-407C
EUWAT(B,D,K,Q,M,S)40,50,60,80,100,120,160,180,200LZY1
EHMC
3 models available 100 l tank for all sizes (even for 35 H.P. chiller) freeze up protection low and high static pump (option) specially designed for Daikin EUWA5-30HD, EUWA5-35HDZ and EUWY5-30HD water chillers standard drain kit (for indoor use) standard dual pressure ports (before & behind the pump)
HYDRAULIC MODULE
models R-22
EUWAT(B,M,D)40,50,60KAY1/T1 EUWAT(B,M,D)80,100,120KAY1/T1
models R-134a
EUWAT(B,D,K,Q,M,S)40,50,60,80,100,120KAXY1/T1 EUWAT(B,D,K,Q,M,S)160,180,200KXY1 EUWT(B,D,K,Q,M,S)40,60,80,100,120KXY1/T1 EUWT(B,D,K,Q,M,S)160,180,200KXY1/T1
Daikin chillers with DDC control can be equipped with DICN which allows the simultaneous operation of up to 4 chillers as if they were a single unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control and is also useful for back up purposes, ensuring that the necessary amount of cooling is available and guaranteeing reliable operation of the chiller plant. This function enables a Daikin 2MW chiller plant to be operated via a single controller.
EHMC10-15-30 AV1010
EHMC
Nominal flow Nominal static height Nominal input Dimensions Weight Sound power/pressure level Operation range (airside/waterside)
70
EHMC10AV1010
l/min mH2O HxWxD W mm kg dB(A) 62 17/34 (1) 630/1,050 (1) 99 63/52
EHMC15AV1010
88 15/27 (1) 650/1,070 (1) 1,284x635x688 102 63/52 -10C to +43C /-10C to +55C
EHMC30AV1010
187 10/27 (1) 1,070/2,090 (1) 105 63/52
71
FWV-BA6V1 / FWV-BAF6V1
Cooling capacity (2-/4-pipe) Heating capacity (2-/4-pipe) Nominal input Dimensions Weight (2-/4-pipe) H/L HxWxD kW kW W mm kg l/s dB(A) dB(A)
1
1.31 / 1.29 1.77 / 1.90 38/20
2
1.98 / 1.95 2.55 / 2.49 66/27
3
2.90 / 2.86 3.64 / 3.68 60/29 560x985x228 26.1 / 27.4 95.9 / 93.9 34/19 48/33
4
3.89 / 3.83 4.88 / 4.74 84/36
6
4.60 / 4.54 6.35 / 6.05 111/54
8
6.29 / 6.20 8.03 / 8.07 180/87
10
7.84 / 7.73 10.1 / 10.2 242/111
560x775x228 20.1 / 21.2 20.6 / 21.7 52.9 / 51.9 33/20 47/34 68.7 / 67.4 40/23 54/37
560x1195x228 31.8 / 33.5 31.8 / 33.5 133.1 / 130.4 38/23 52/37 171.7 / 168.3 46/32 60/46
560x1405x253 40.8 / 43.1 40.8 / 43.1 224.6 / 220.1 48/35 62/49 278.9 / 273.4 53/40 67/54
FA N C O I L U N I T S
FWV(M)/FWH(M)/FWHC
5 different models, several capacity versions low sound level fashionable design wide range of options to be combined with water chiller or boiler washable air filter
Air flow rate (2-/4-pipe) M Sound pressure level Sound power level H/L H/L
FWVM-BA6V1 / FWVM-BAF6V1
Cooling capacity (2-/4-pipe) Heating capacity (2-/4-pipe) Nominal input Dimensions Weight (2-/4-pipe) Air flow rate (2-/4-pipe) M Sound pressure level H/L Sound power level H/L H/L HxWxD kW kW W mm kg l/s dB(A) dB(A)
1
1.31 / 1.29 1.77 / 1.90
2
1.98 / 1.95 2.55 / 2.49
3
2.90 / 2.86 3.64 / 3.68 60/29 535x708x223 19.5 / 20.8 95.9 / 93.9 37/22 48/33
4
3.89 / 3.83 4.88 / 4.74
6
4.60 / 4.54 6.35 / 6.05
8
6.29 / 6.20 8.03 / 8.07
10
7.84 / 7.73 10.1 / 10.2
38/20 66/27 535x498x223 14.6 / 15.7 52.9 / 51.9 36/23 47/34 15.1 / 16.2 68.7 / 67.4 43/26 54/37
84/36 111/54 535x918x223 23.8 / 25.5 133.1 / 130.4 42/26 52/37 24.6 / 26.3 171.7 / 168.3 49/35 60/46
180/87 242/111 535x1,128x248 31.8 / 34.1 224.6 / 220.1 51/38 62/49 31.8 / 34.1 278.9 / 273.4 56/43 67/54
FWH-BA6V1 / FWH-BAF6V1
Cooling capacity (2-/4-pipe) Heating capacity (2-/4-pipe) Nominal input H/L Dimensions HxWxD Weight (2-/4-pipe) Air flow rate (2-/4-pipe) M Sound pressure level Sound power level H/L H/L kW kW W mm kg l/s dB(A) dB(A)
1
1.31 / 1.29 1.77 / 1.90 38/20 20.9 / 22 52.9 / 51.9 33/20 47/34
2
1.98 / 1.95 2.55 / 2.49 66/27 22.1 / 23.2 68.7 / 67.4 40/23 54/37
3
2.90 / 2.86 3.64 / 3.68 60/29 228x985x560 27.7 / 29 95.9 / 93.9 34/19 48/33
4
3.89 / 3.83 4.88 / 4.74 84/36 33.3 / 35 133.1 / 130.4 38/23 52/37
6
4.60 / 4.54 6.35 / 6.05 111/54 33.3 / 35 171.7 / 168.3 46/32 60/46
8
6.29 / 6.20 8.03 / 8.07 180/87 42.3 / 44.6 224.6 / 220.1 48/35 62/49
10
7.84 / 7.73 10.1 / 10.2 242/111 43.1 / 45.4 278.9 / 273.4 53/40 67/54
228x775x560
228x1,195x560
253x1,405x560
FWHM-BA6V1 / FWHM-BAF6V1
Cooling capacity (2-/4-pipe) Heating capacity (2-/4-pipe) Nominal input Dimensions Weight (2-/4-pipe) Sound pressure level Sound power level
72
1
1.31 / 1.29 1.77 / 1.90 38/20
2
1.98 / 1.95 2.55 / 2.49 66/27
3
2.90 / 2.86 3.64 / 3.68 60/29 223x916x535 20.4 / 21.7 95.9 / 93.9 34/19 48/33
4
3.89 / 3.83 4.88 / 4.74 84/36
6
4.60 / 4.54 6.35 / 6.05 111/54
8
6.29 / 6.20 8.03 / 8.07 180/87
10
7.84 / 7.73 10.1 / 10.2 242/111
H/L HxWxD
223x706x535 15.3 / 16.4 16.1 / 17.2 52.9 / 51.9 33/20 47/34 68.7 / 67.4 40/23 54/37
223x1,126x535 24.8 / 26.5 25.1 / 26.7 133.1 / 130.4 38/23 52/37 171.7 / 168.3 46/32 60/46
248x1,336x535 33.3 / 35.6 33.3 / 35.6 224.6 / 220.1 48/35 62/49 278.9 / 273.4 53/40 67/54
73
Daikin Chiller
S E L E C T I O N S O F T WA R E
Purpose designed, user friendly and powerful, this facility simplifies and speeds up the selection of Daikin chillers. The built-in programme enables the most suitable selection to be made according to cooling/heating capacity and specified design conditions. Extensive print outs are available. The Daikin chiller selection programme runs under Windows95, Windows98 and WindowsNT, without specific computer requirements. Daikin chillers are equipped with a user friendly electronic controller, complete with electronic sensors to monitor and provide information on water inlet and outlet temperatures and air/coil temperatures. The controller also incorporates a number of safety devices, timer functions, an adjustable thermostat function etc. The selection software covers a complete database of all chiller units, which includes specifications, wiring diagrams, piping diagrams, technical data, options and installation space.
2-PIPE SYSTEM
Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level unit decor. panel unit decor. panel H H/L kW kW W mm mm kg kg l/s dBA
FWHC2B
1.96 3.58 48 449x591x550 48x855x550 16 4 101.7 30/19
FWHC3B
2.58 4.79 71 449x721x550 48x985x550 19 5 141.7 32/21
FWHC4B
3.71 6.80 85 449x871x550 48x1,135x550 23 7 188.3 32/21
FWHC6B
5.36 9.79 112 449x1,181x550 48x1,445x550 32 8 283.3 33/22
FWHC8B
7.22 13.52 172 449x1,491x550 48x1,755x550 39 11 376.7 36/26
FWHC12B
9.32 17.6 207 449x1,951x550 48x2,215x550 50 13 566.7 38.5/27
4-PIPE SYSTEM
Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Air flow rate Sound pressure level
74
FWHC2BF
kW kW W mm mm kg kg l/s dBA 2.26 2.50 44 449x591x550 48x855x550 18 4 101.7 30/19
FWHC3BF
2.85 3.22 64 449x721x550 48x985x550 21 5 141.7 32/21
FWHC4BF
3.63 4.14 68 449x871x550 48x1,135x550 26 7 183.3 32/21
FWHC6BF
4.47 5.31 99 449x1,181x550 48x1,445x550 36 8 271.7 33/22
FWHC8BF
6.38 8.02 129 449x1,491x550 48x1,755x550 44 11 350 36/26
FWHC12BF
7.85 10.86 219 449x1,951x550 48x2,215x550 57 13 511.7 38.5/27
75
EPC99.09DEngOK
31/03/00
12:21
Page 78
5
CONDENSING UNITS
ER
split type condensing unit slim and compact easy to install and maintain indoor or outdoor installation
CONDENSING UNIT
COOLING ONLY
Cooling capacity Nominal input Dimensions Weight HxWxD kW kW mm kg dB(A)
ER3DA
8.3 3.0 796 x 922 x 373 85 67/54
ER5DA
13.0 4.5 1,179 x 922 x 373 130 71/58
ER8DA
22.2 7.1 1,254 x 1,390 x 373 185 72/59
ER10DA
26.6 9.5 1,560 x 1,390 x 373 210 73/60
77