Anda di halaman 1dari 97

SERVICE MANUAL

MODEL :

SM-100
EDITION
1 nd 2 rd 3 th 4
st

Month December March February February

Year 2004 2006 2007 2009

SHANGHAI TERAOKA ELECTRONIC CO., LTD


TECHNICAL SUPPORT DEPARTMENT
1rd Floor of 2nd Building, Jia Yuan Business Center, 51# Long Wu Road, Shanghai China 200232. TEL : +86-21-6408-5151 FAX : +86-21-6408-3468
EMAIL ADDRESS :steservice@digi-scale.com

Table of Content
1. GENERAL INFORMATION
........................................................................1

1.1 Overall View


...................................................................................................................................... ............. 1

1.2 Display Panel.........................................................................................................................


......................... 3

1.3 Key Panel.........................................................................................................................


.................................. 3

1.4 Thermal Printer Head


............................................................................................................................ 9

1.5 Features
...................................................................................................................................... .......................10

1.6 Specification ........................................................................................................


..........................................11

1.7 Label Type


...................................................................................................................................... ................12

2. Initial Setup
.......................................................................................................... ........13

2.1 Setup
...................................................................................................................................... ..............................13

2.2 Location of Switches and Connectors .................................................................................. 15

2.3 Memory Initialisation..........................................................................................................


.................. 15

2.4 Default Specification Setting


......................................................................................................... 16

3. Calibration .................................................................................
....................................18

3.1 Calibration Operation


.......................................................................................................................... 18

3.2 Exit Calibration .............................................................................................................


.............................19

4. Software Setting
....................................................................................................... 20

4.1 Software Version Upgrade


.............................................................................................................. 20

4.2 Specification Setting


..............................................................................................................................32

5. Adjustment................................................................................
................................... 34

5.1. Peer Sensor Voltage and Label Sensor Sensitivity Adjustment....................34 5.2. Adjustment of Printing Position............................................................................................... 37 5.3. Voltage Checkpoint
..............................................................................................................................38

6. Interface
.......................................................................................................... ............... 39

6.1. PC Interface .................................................................................................................


................................39

6.2. Scale Ethernet Address


..................................................................................................................... 40

6.3. Scale IP Address


...................................................................................................................................... 41

6.4. Connection Method


.............................................................................................................................42

6.5. Wire Configuration


...............................................................................................................................44

7. Miscellaneous
.......................................................................................................... .. 46

7.1. Mode Change


...................................................................................................................................... .......46

7.2. Span Switch Status.......................................................................................................................


..........46

7.3. Clear All PLU Data ...........................................................................................................................


....46

7.4. Thermal Head Usage .......................................................................................................................


.... 47

7.5. IP ADDRESS
...................................................................................................................................... ......47

7.6. SERVER IP ADDRESS................................................................................................................


.. 47

7.7. SUBNET MASK


....................................................................................................................................4 7

7.8. MAC ADDRESS ................................................................................................................


....................48

7.9. SERIAL NO
...................................................................................................................................... .........48

8.0. ASCII CHARACTER ..........................................................................................................


.............. 49

8. Appendix
.......................................................................................................... .................

A. SpecificationList_V200 B. FlexibleL Barcode Setting Guide C. Traceability Setting Guide D. Nutrition Setting Guide E. PC-FL1 Operation Guide F. Circuit

9. Error Message......................................................... .................

SM 100

GENERAL

1.

GENERAL

1.1 OVERALL VIEW


Bench Type

Pole Type

Elevated Type

1 1

SM 100
Bench-CS Type

GENERAL

Pole-CS Type

Hand Type

SM 100 1.2 DISPLAY PANEL


25 digits 19 segments TN type LCD

GENERAL

32 202 full dot Matrix Green LCD

1.3

KEY PANEL

Preset Keys Type ------ B/P 32 Preset keys:

40Preset Keys:

SM 100
56 Preset Keys Type ------ PCS(New), PCS+ (New)

GENERAL

74 Preset Keys Type ------ EV, PCS(Old)

76 Preset Keys Type (Hanging)

SM 100
ON/OFF KEY

GENERAL

Turn display "ON" or "OFF". PRESET KEY

P1 ~ P40 (B/P) P1 ~ P74 (EV) P1~P32(BCS) P1~P56(PCS) P1~P76(H)


NUMERIC KEYS

Set up or call either unit price and tare value.

0~9
TARE KEY

Enter numeric data.

Set or Clear Tare value. Select "NO" in S and Z Mode. Item test print in S Mode. CLEAR KEY

C
RE-ZERO KEY

For Back space or Clear numeric value. Select "YES" in S and Z Mode.

Reset weight to ZERO. PREPACK KEY Switch Manual mode and Pre-pack mode alternatively. (The mode status will be indicated in the P and M indicator.) P - PRE-PACK MODE M - MANUAL MODE

AUTO
CHANGE KEY

Calculate the Changed Amount. Escape the Programming screen without saving data in S Mode.

MULTIPLLE KEY

Register the number of Non-Weight products. Select programming item such as PLU data, Shop Name in S Mode. Select Report Type in X Mode. Select Data Transaction Type in Z Mode.

CLERK KEY

V1~V4
VOID KEY

Accumulate the Total Price.

PLU KEY

Correct the sales data.

PLU
FEED KEY

Call up PLU data in R Mode. Store the programmed data in S Mode.

Feed Label or Receipt paper PRINT KEY

Print out Label or Receipt.

Note: BCS or PCS stands for the scale with cassette.

MODE SELECT KEY Five Modes can be selected using this key. Indicator R - REGISTRATION MODE (All the sales transactions are performed.) Indicator X - CHECK MODE (Printing out and sales report.) Indicator S - PROGRAM MODE (Programming preset data, such as products, data, shop name, etc.) Indicator Z - TOTAL MODE (Clear sales data stored.) Indicator X (Blink) - Password Setting Mode (Set PASS WORD for X, S, Z mode, set PASSWORD for PASSWORD MODE when all indicators(R, X, S, Z) blink)

Decrease/Increase Specification Count key

, <<,>>

Decrease/Increase Only used when Setting SPEC 141 & 142

Select parameter data such as SPEC data. Move cursor left or right.

1.4 Thermal Printer Head Max Printing With: 56mm

1.5

FEATURES
Digital printing scale consists of electronic cash registers function and label printing function. High-speed, high reliability thermal head printer. Easy paper handing achieved special designed mechanism. Built-in clock automatically updates data and time. Quick response to weight changes. Capacity and Resoultion 3kg 6kg 1/3000S, 12kg 15kg 1/3000S, 1/3000 1/3000M, 1/7500S 12lb 1/3000S, 1/3000 1/3000M, 1/7500S 15lb 1/3000S, 1/3000M, 1/6000S 30kg 1/3000S, 1/3000M, 1/6000S 30lb 1/3000S, 1/3000M, 1/6000S 60lb 1/3000S, 1/3000M, 1/6000S 1/3000 60kg

Capacity

Resolution

1/3000

1/3000M, 1/6000S

Capacity

3lb 1/3000S,

6lb

Resolution

1/3000M 1/6000S

Internal count: 1/90000. Calibrating by software. Customer and operator display (optional customer pole display). SM-100: 25 digits x 19 segments TN type LCD with back-light for numeric digit and character display. SM-100+: 32 x 202 full dot Martix Green LCD display. membrane keys a. b. c. d. ON/OFF key 10 Numeric keys, to key in numeric data. Preset keys, to preset PLU or function into the key. 16 Operational keys, to perform various functional operations.

18 data files, Department, Main Group, PLU, etc. Various reports, PLU daily report, Sales daily report,24 hours daily report, etc. Ethernet function. Optional wireless Ethernet bridge. RS232C interface for data communicate and barcode scanner connection. Optional cash drawer. Compact housing. 9

SM 100 1.6 SPECIFICATION

GENERAL

1.6.1 Display
SM-100 25 digits 19 segment TN type LCD with back-light for numeric digit and character display. Tare weight display : 4 digits. Weight display Unit price display Total price display : 5 digits. : 6 digits. : 7 digits.

SM-100+ 32 x 202 full dot Martix Green LCD display. Tare weight display Weight display Unit price display Total price display : 4 digits. : 5 digits. : 6 digits. : 7 digits.

1.6.2 Operating Conditions


Power Source Operating Temperature Operating Humidity Power Consumption : AC 110V,220V(+10%,-15%), 50~60Hz. : -10 C ~ +40 C. : 15% ~ 85% RH. : 70 W.

1.6.3 Dimensions
Platter size Bench, Pole and Elevated : 386(W) x 270(D) mm. Bench-CS and Pole-CS Hanging a) b) c) d) e) f) : 359(W) x 277(D) mm. : 274(d) x 35(h) mm.

Overall size Bench Pole Elevated Bench-CS Pole-CS Hand : 386(W) x 415(D) x 127(H) mm. : 386(W) x 478(D) x 480(H) mm. : 386(W) x 416(D) x 550(H) mm. : 380(W) x 360(D) x 162(H) mm. : 380(W) x 380(D) x 509(H) mm. : 340(W) x 310(D) x 544(H) mm.

10

SM 100 1.7 LABEL TYPE

GENERAL

The label diameter range is from 40 to 105 mm.

Note: Labels must be winding outwards (on top backing paper) and not inwards (under backing paper) within the core (see diagram above). If labels are wound wrongly, printing problem may result. We do not recommend the use of varnish labels.

Label Type T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 S A B C F1 F99

Dimension (mm) 28 X 56 31 X 56 34 X 56 40 X 56 43 X 56 46 X 56 49 X 56 55 X 56 37 X 56 40 X 56 43 X 56 49 X 56 28 X 37 46 X 37 46 X 37 62 X 37 Free Format

1 11

SM 100

INITIAL SETUP

2.
2.1

INITIAL SETUP
SETUP

Indication of Assemble

1 13

SM 100 Bubble Adjustment

INITIAL SETUP

Bubble

Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the centre as shown above.

1 14

SM 100 2.2 LOCATION OF SWITCHES AND CONNECTORS

I INITIAL SETUP

Power Switch Fuse Holder Cash Drawer Port RS232 Port Ethernet Port

Span Switch

2.3

MEMORY INITIALISATION

To clear all memory.


OPERATION DISPLAY PT Z1.0 [Rezero]+[2][3][0] [] [] [] [*] [C] or [T] Z1.0 kg RESET CLEAR CLEAR CLEAR CLEAR CLEAR RESET /kg SALES PLU VENDER REPORT MEMORY MEMORY SALES DAILY FILE DATA FILES DATA Y-C N-T DAILY Z mode. Lamp Z turns on. PLU file. Vender transaction data. Report files. All files in memory. [C] to clear file data,[T] to quit. Return to Z mode. REMARK

15

SM 100 2.4 DEFAULT SPECIFICATION SETTING Default SPEC setting of individual country. (Please turn on the span switch before proceed this process.) Country Set
OPERATION DISPLAY PT
Z1.0 [Rezero]+[8][8][2][2] [>>] [*] [C] [X] [*] [X] [*] [X] [*] [C] Z1.0 LOAD

INITIAL SETUP

kg
RESET SPEC SPEC DEFAULT SCALE SCALE SCALE SCALE SCALE SCALE CLEAR RESET

/kg
SALES 2-STD 3-CN SPEC TYPE TYPE CAP. CAP. RES. RES. MEMORY SALES

DAILY COUNTRY COUNTRY Y-C N-T POLE BENCH 3KG 6KG 1/3000S 1/3000M Y-C N-T DAILY

REMARK
Z mode.Lamp Z turns on. Set country setting. [>>],[<<] or [X] to select country.[*] to update country setting. [C] to load default SPEC setting,[T] to skip. Set scale type. [X],[] to select type,[*] to update type setting. Set scale capacity. [X],[ ] to select capacity,[*] to update capacity setting. Set resolution. [X],[ ] to select resolution,[*] to update resolution setting. [C] to clear memory,[T] to skip. Return to Z mode.

Note 1: For the first using of SM-100,Please take this operation for initialization. Note 2: Enter a number that represent a country in the country list (refer to the table below) to

initialise and country set.

SM 100
COUNTRY LIST
No. Country Code 0 AA 1 U1 2 STD 3 CN 4 HK 5 TW 6 EX 7 KE 8 AR 9 SF 10 CS 11 GC 12 TU 13 CV 14 HG 15 PL 16 UR 17 AS 18 DM 19 FL 20 NW 21 SD 22 PG 23 UK 24 IL 25 IL (LB) 26 CA 27 CA (LB) 28 AG 29 MX 30 BZ 31 CE 32 EA 33 JD 34 LN 35 IRN 36 CR 37 TL 38 EC 39 NL 40 BG Country Japan U.S.A. Standard China Hong Kong Taiwan Export Korea Australia And New Zealand South Africa Cyprus Greece Turkey Czech Republic Hungary Poland Russia Austria Denmark Finland Norway Sweden Portugal United Kingdom Ireland (Kg) Ireland (Lb) Canada (Kg) Canada (Lb) Argentina Mexico Brazil Chile Egypt Jordan Lebanon Iran Canary Islands Thailand European Community Netherlands Belgium No. Country Code 41 SA 42 IC 43 IE 44 CB 45 KY 46 IR 47 VY 48 MS 49 SN 50 VZ 51 CO 52 MA 53 FR 54 WG 55 BL 56 BW 57 CP 58 LS 59 MU 60 MW 61 MZ 62 NM 63 RE 64 SH 65 SW 66 WZ 67 ZW 68 AE 69 TT 70 UD 71 LV 72 CVS 73 SK 74 SV 75 UA 76 KZ 77 IT 78 SZ 79 ID 80 CD

INITIAL SETUP

Country Saudi Arabs Iceland Indonesia Cuba Kenya Israel Slovenia Malaysia Spain Venezuela Croatia Macedonian France Germany Bulgaria Botswans Comores Lesotho Mauritius Malawi Mozambique Namibia Reunion Seychelles Swaziland Zimbabwe Zambia U.A.E Trinidad and Tobago Uganda Latvia Slovakia Sri Lanka Slovenia Ukraine Kazakhstan Italy Switzerland India New Caledonia

17

SM100

CALIBRATION

3.

CALIBRATION

Prior to Calibration, please refer that the specification indicating weight capacity, minimum graduation, and load cell sensitivity are correctly set. Caution: z It can only work when SPAN SWITCH is on (ENABLE). Before Calibrating, please enter Z mode.

3.1 CALIBRATION OPERATION


DISPLAY PT Z1.0 kg RESET CAL 00 -----CAL SP -----Z1.0 RESET SALES DAILY Calibrating Span. Go back to Z mode. Lamp Z always light. /kg SALES DAILY SPAN Enter

OPERATION

REMARK SWITCH [8][7][1][5] is on while

Press SPAN SWITCH [Rezero]+[8][7][1][5] Ensure no weight on platter,[*] After storing the zero Point IR count Put full capacity weight on platter.[*] After calibration

(ENABLE). depressing [Rezero]. Calibrating zero point.

18

SM100 3.2 EXIT CALIBRATION


DISPLAY PT Z1.0 kg RESET CAL 00 Z1.0 RESET CAL 00 -----CAL SP Z1.0 RESET SALES DAILY SALES DAILY /kg SALES DAILY SPAN Enter

CALIBRATION

OPERATION

REMARK SWITCH [8][7][1][5] is while

Press SPAN SWITCH [Rezero]+[8][7][1][5] [T] [Rezero]+[8][7][1][5] [*] After storing the zero Point IR count [T]

on(ENABLE). depressing [Rezero]. Escape to Z mode. Lamp Z always light The IR count will be taken as the zero point IR count. Calibrating Span. Escape to Z mode. Lamp Z always light.

19

SM 100

SOFTWARE SETTING

4
4.1

SOFTWARE SETTING
SOFTWARE VERSION UPGRADE

Update Method Introduction


SM-100 use flash RAM instead of EPROM for the main program storage of the scale. Before the boot program Version 1.10, we just have one method to update the scales software: PC to scale via RS232 interface. After the boot program Version 1.10 (including V1.10), we add a new method to update the scales software: update the scale by ethernet. So you can choose either method between these two ones to update your scale. Now we will set two parts to introduce the steps of these two updating methods.

Update Steps Introduction I. Ethernet Update Method


1. Cable & Connection There are also two ways to connect the PC and the scale in updating the scale by ethernet. 1) PC to Scale

Crossing Twisted Cable PC Sm-100

2) Connect by Hub
Normal Twisted Cable Normal Twisted Cable

PC

HUB

Sm-100

20

These two twisted cable obey the EIT/TIA 568 standard. 1 2 3 4 5 6 7 8 T568A line series Green &White Green Orange & White Blue Blue & White Orange Brown & White Brown 1 2 3 4 5 6 7 8 T568B line series Orange & White Orange Green &White Blue Blue & White Green Brown & White Brown

crossing twisted cable: one end with T568A line series, another with T568B line series normal twisted cable: two ends both with T568B line series 2. PC Setting & Programmer Version We use Mini Programmer (Version 2.00) as the tool to update the scale. As it needs a default visual IP address for the PC by this kind of update method, You must set your PCs IP address within the range of 10.10.10.1-----10.10.10.240, before you start the software to update the scale. If you dont set the IP address like this, you can see an alarm window as Pic. 1 when you start Mini Programmer.

Pic. 1 3. Updating Steps 1) How to start ethernet updating? A. Turn on the switch on the bottom of the scale. B. Power off the scale by pressing On/Off Key. C. After that, press and hold [Re-Zero] and [Preset 22], then start the scale by pressing the On/Off Key. D. The screen will display the version of the current boot program for two seconds. E. Only in new versions(version of the boot program newer than 1.10), you can choose 2-ethernet. 2) Display on the scales screen A. If you choose 2 and the scales connection is correct, it will display waiting for connect. B. Then the message on the scales screen is getting IP address. C. After this, it will display 001 scale ready update. D. You cant stop it unless you press On/Off key. If you want to continue updating. You also dont need to press any key on the scale until Mini Programmer begin to run.

3) How to upload the scale by Mini Programmer? A. Select SM-100 and press ok

B. Set the port

Select ethernet and press OK

C. Download boot program and update the scale Select menu File->Load File To Programmer Buffer

Open the source file of boot program (e.g. sm100bv100.hex)

You can see a speed mode select window here.

Select menu Flash->Program

Notice: The message 001 scale ready update must be displayed on the screen of the scale before pressing the run button.

After the transmission has completed, select menu File->Clear Buffer.

Notice: 1.If the boot program of this version is already in the scale, you dont need to upload it again, skip it and upload the main program. 2.If the scale is updated from 1.xx to 2.xx,firstly you must update the boot program of the version. D. Download main program file You must power off the scale and start the ethernet upload method again when you have finished a program uploading. The steps of uploading the main program file is also like uploading the boot program file. The file you need to open is like Pic. 2

Pic. 2

E. Download word-stock file The steps of uploading the word-stock file is also like uploading the boot program file. The file you need to open is like Pic. 3

Pic. 3 F. Download const text file The steps of uploading the const text file is also like uploading the boot program. The file you need to open is like Pic. 4

Pic. 4 G. Exit Mini Programmer Note: please update the scale according to sequence above.

RS232C Method
4. Cable Connection 3 Pins are used for data transmission between PC and SM-100 9 Pin D-Sub Female Connectors for this cable:

PC Serial Port 9 Pin D-Sub (Female)

SM-100 RS-232C 9 Pin D-Sub (Female)

Pin 1 2 3 4 5 6-9

Signal N.C. RXD TXD N.C. GND GND

Signal N.C. RXD TXD N.C. GND N.C.

Pin 1 2 3 4 5 6-9

5. Update Steps 1) How to start RS232C updating A. Turn on the switch on the bottom of the scale. B. Power off the scale by pressing the On/Off Key. C. After that press and hold [Re-Zero] & [Preset 22], then start the scale by press ing the On/Off Key. D. It will display the version of the current boot program for two seconds.

E.

If the scale boot version is newer than 1.10, it will display a updating method choice like 1-RS232 2-ETHERNET on the screen. you can press Numeric 1 to choose 1-RS232C. If the boot version is older than 1.10, the scale will not display the choice. F. Then the Scale will display PROGRAM. You cant stop it, unless you press Tare or On/Off Key. 2) Start Mini Programmer 1. Select SM-100 and press Ok

2.

Set the Port:

Select RS232 and press OK

3.

Download the boot program and update the scale Select menu File->Load File To Programmer Buffer

Open the source file of the boot program (e.g. sm100bv100.hex)

Select menu Flash->Program

Notice: The message 001 scale ready update must be displayed on the scale before pressing the run button.

After the transmission has completed, select menu File->Clear Buffer.

Notice: If the boot program of this version is already in the scale, you dont need to upload it again, skip it and upload the main program.

4. Download main program file You must power off the scale and start the ethernet upload method again when you have finished a program uploading. The steps of uploading the main program file is also like uploading the boot program file. The file you need to open is like Pic. 2

Pic. 2 5. Download word-stock file The steps of uploading the word-stock file is also like uploading the boot program file. The file you need to open is like Pic. 3

Pic. 3 6. Download const text file The steps of uploading the const text file is also like uploading the boot program. The file you need to open is like Pic. 4

Pic. 4 7. Exit Mini Programmer

4.2

SPECIFICATION SETTING Before Specification setting, please press the mode button to enter Z mode. The detail specification list , please see the appendix. Customer SPEC Setting

4.2.1

To change setting of the Customer SPEC if there are some SPEC setting in it need to be alter.
OPERATION DISPLAY PT Z1.0 kg RESET /kg SALES XXX (setting) DAILY XXX (former) Z mode. Lamp Z turns on. Enter [1][4][1] while [Rezero]. XXX:SPEC data [ ]key only increase specification count, it does not update SPEC data. []key only decrease specification count, it does not update SPEC data. It goes to a designed specification count. (000~441 is enabled) [>>] key select SPEC data. Move cursor right. [<<] key select SPEC data. Move cursor left. depressing REMARK

[Rezero]+[1][4][1]

SPEC 000

[]

SPEC 001

XXX

XXX

[]

SPEC 000

XXX

XXX

[1][7] [X] [>>] [<<] [1] [*] [C] [PLU] * Note 1 Z1.0

SPEC 000 SPEC 017 SPEC 017 SPEC 017 SPEC 017 SPEC 018 SPEC 018 RESET

017 XXX XXX XXX 001 XXX 000 SALES

XXX XXX XXX XXX XXX XXX XXX DAILY

Clear the enter data. Store the updated specification and escape to Z mode.

* Remark:

The Weight in the display window will display the SPEC number. The Unit Price window will display the new value setting entered. The Total Price window will display the old value setting. The selection you have made will be highlighted in the dot matrix display. Please use [] to increase spec count, [] to decrease spec count, [*] to store a new value and [PLU] to save spec setting.

4.2.2

Weight & Measurement SPEC Setting

To change the setting of the Weight & Measurement SPEC if there are some SPEC need to alter. (Please turn on the span switch when using this process)
OPERATION Press SPAN SWITCH [Rezero]+[1][4][2] DISPLAY PT Z1.0 kg RESET /kg SALES XXX (setting) DAILY XXX (former) REMARK

SPAN SWITCH is on(ENABLE). Enter [1][4][2] while [Rezero]. XXX:SPEC data [ ]key only increase specification count, it does not update SPEC data. []key only decrease specification count, it does not update SPEC data. It goes to a designed specification count. (600~709 is enabled) [>>] key select SPEC data. Move cursor right. [<<] key select SPEC data. Move cursor left. [*] key to update specification, increase specification count. Clear the enter data. Store the updated specification and escape to Z mode. depressing

SPEC 600

[]

SPEC 601

XXX

XXX

[]

SPEC 600

XXX

XXX

[6][1][5] [X] [>>] [<<] [1] [*] [2] [C] [PLU] * Note 1 Z1.0

SPEC 600 SPEC 615 SPEC 615 SPEC 615 SPEC 615 SPEC 616 SPEC 616 SPEC 616 RESET

615 XXX XXX XXX 001 XXX 002 000 SALES

XXX XXX XXX XXX XXX XXX XXX XXX DAILY

Note 1: If press [T] key, it does not store the updated specification and escape to Z mode.

* Remark:

The Weight in the display window will display the SPEC number. The Unit Price window will display the new value setting entered. The Total Price window will display the old value setting. The selection you have made will be highlighted in the dot matrix display. Please use [] to increase spec count, [] to decrease spec count,
[*] to store a new value and [PLU] to save spec setting.

SM100

ADJUSTMENT E

5.
5.1

ADJUSTMENT
PEEL SENSOR VOLTAGE AND LABEL SENSOR SENSITIVITY ADJUSTMENT

Label Sensor

LOCATION OF PEEL AND LABEL SENSOR

SM100
5.1.1 Peel Sensor Voltage

ADJUSTMENT

To set the peel sensor voltage if the peel sensor is not working normally in some situations like temperature and humidity change.
OPERATION DISPLAY PT Z1.0 kg RESET /kg SALES DAILY Z mode. Lamp Z turns on. Enter [5][1][5] while depressing [Rezero]. /kg window displays label paper peel sensor voltage, window displays new setting value. [T] Z1.0 RESET SALES DAILY [T] key to exit. REMARK

[Rezero]+[5][1][5]

PEEL

PFD

0.5

0.0

5.1.2

Label Sensor Sensitivity

Adjust here for sensor

When the label came out three or more when feeding or printing, the sensitivity of the sensor need to be adjusted to sense the gap between the label better. There is a variable resistor near the sensor. Adjust it to increase or decrease the sensitivity. Clockwise is to increase the sensitivity and anti-clockwise is to decrease the sensitivity.

SM100
OPERATION DISPLAY PT Z1.0 kg RESET /kg SALES DAILY

ADJUSTMENT
REMARK Z mode. Lamp Z turns on. Enter [5][1][6] while depressing [Rezero]. /kg window

[Rezero]+[5][1][6]

GAP

PFD

2.0

3.1

displays label paper gap sensor voltage, window displays new setting

[T]

Z1.0

RESET

SALES

DAILY

value. [T] key to exit.

SM100 5.2 ADJUSTMENT OF PRINTING POSITION


DISPLAY PT Z1.0 kg RESET /kg SALES DAILY Z mode.

ADJUSTMENT

This function is used to adjust the print position on label.


OPERATION REMARK

Lamp Z turns on. Enter [5][1][4] while depressing [Rezero]. /kg window display old setting, window display new setting. To move up the point position on

[Rezero]+[5][1][4]

ADJ

PFD

[1][0]

ADJ

PFD

10

label, enter the new value by numeric key (Ex. 10 dots). If you want to move down the print position, please enter the new value by numeric key (Ex. 10dots), and then press [] key.

[1][0][]

ADJ

PFD

10

[PLU] [T]

0.000 Z1.0

0.000 RESET

0.00 SALES

0.00 DAILY

Save the feed setting. If you want to exit without saves the setting, press [T] key to exit.

PRINTING TOO HIGH (ADJUST DOWNWARD)

CORRECT POSITION

PRINTING TOO LOW (ADJUST UPWARD)

SM100 5.3 VOLTAGE CHECKPOINT

ADJUSTMENT

There are several voltage checkpoints on the PCB boards. Below are some reference voltage points that are commonly use. VOLTAGE POINT VCC VTH VBB HVcc VOLTAGE 3.3 V 24 V 3V 5V PURPOSE Provide voltage for most of the IC Provide voltage mainly to the thermal head Provide backup voltage for the RAM IC

The tolerance of all the voltage is about 5% except VTH is +2% and -5%

SM100

INTERFACE

6.
6.1

INTERFACE
PC INTERFACE

SM 100 can be connect to PC through Ethernet interface and RS232C. See below for the connection method. CONFIGURATION OF PC ETHERNET CARD Window version client driver Any Ethernet cards can be used for PC running the Window version client driver Windows 98 My Computer Control Panel NetworkTCP/IP of Ethernet card (Select Properties) IP address : 192.168.1.XXX ------ XXX - can be any number. But preferable 100 to 255. Submask : 255.255.255.0 Above IP address is use as a standard address to use for SM 100 Ethernet communication. If whatever reason, the IP address had to be change, it may do so. But the scale IP address had to be change at the SM 100 scale also so that they are within the same network. Eg. If the computer IP address is 192.168.1.XXX, the SM 100 scale IP address has to be change to 192.168.1.XXX. The last three digits of the IP address should not be similar within the computer and scales at all time. As can see the first three set of number of the IP address of the computer and scale must be the same.

39

SM100

INTERFACE

Before setting the SPEC setting of the scale, please check below.

6.2

SCALE ETHERNET ADDRESS

The main board have a Scale Ethernet Address that is set during production. This address is a hardware setting for Ethernet communication. But when changing a new main board, the new main board did not have any this address. If the scale is using Ethernet communication, a Scale Ethernet Address is needed apart from software IP address. Please take note that the Scale Ethernet Address can only input once after saving. Please view and note down the Scale Ethernet Address of the old main board before changing the new main board. Below procedure is to view and input the Scale Ethernet Address. Please turn on the span switch before proceed. KEY TO PRESS
PT kg

DISPLAY /kg SALES . Daily .

OPERATION

Go to Z mode [REZERO] + [0][6][1][2]

Z1.0 ETHER

RESET NET

[0][0][0][6][C][0] [0][0][0][0][2] [4] [PLU] [T] Power off the scale * IMPORTANT :

ETHER Z1.0 Z1.0

NET RESET RESET

0006C SALES SALES

0000024 Daily Daily

At Z mode Viewing of Ethernet address For new main board, it can act as input of the address if the address shown .. Else it would not let you to input. For input only. Enter Ethernet address e.g. 0006C 0000024 Save address and escape to Z mode. After saving it will not be able to input again. Escape to Z mode without saving. Turn off the power and do the memory clear process.

Please take note that this is a one time setting. It cannot be change after setting it. Please check the old address and input accordingly. As same internal Ethernet address in a network may conflict during communication.

6.3

SCALE IP ADDRESS
40

SM100

INTERFACE

This is to set the IP address for PC communication using Ethernet for specific IP address. It should not be confused with the Scale Ethernet Address as above. The Scale Ethernet Address is mainly for hardware and Scale IP Address is for software. The software when communicating to the scale must specify the same IP address on the scale else it will give error. The default is 192.168.000.000 where the last three digit will change when SPEC 135 change. Please turn on the span switch before proceed. KEY TO PRESS
PT kg

DISPLAY /kg SALES . 192168 Daily .

OPERATION

Go to Z mode [REZERO] + [0][4][1][6] [1][9][2][1][6][8] [0][0][1][0][1][6]

Z1.0 SCALE SCALE

RESET IP IP

001016

[PLU] [T]

Z1.0 Z1.0

RESET RESET

SALES SALES

Daily Daily

At Z mode Input or viewing of IP address Enter IP address e.g. 192.168.001.016 ( The last 3 digits cannot be input as it will change when SPEC 135 change) Save address and escape to Z mode Escape to Z mode without saving.

41

SM100 6.4 CONNECTION METHOD

INTERFACE

6.4.1 RS232C Interface with PC PC Scale

Com 1 / Com 2

RS232C Port

* Note : Only 1 scale can be connect in this method. SPEC setting on scale : SPEC 48 SPEC 51
0 1 1200 2400

Scale number (For 4 line / RS232C port) Baud rate for SIO (RS232C port)
2 3 4800 9600 4 5 19200 38400

Enter number between 1 to 999,999

6
0 0 0

76800 Data length for SIO (For RS232C port)


1 1 1 8 bit Odd 2 bits 2 Even 7 bit None 1 bit

SPEC 52 SPEC 53 SPEC 54

Parity for SIO (For RS232C port) Stop bit for SIO (For RS232C port)

6.4.2 Ethernet Connection (Ethernet Interface)


42

SM100

INTERFACE

Scale #1

Scale #2

Scale #3

Scale #4

Scale #5

PC HUB

SPEC setting on scale : SPEC 49


0 1 2

CLIENT / SERVER INTERFACE


3 4 Not used 4 lines, RS485 (For future use)

No interface Ethernet - Coaxial Cable Ethernet - Twisted Cable

SPEC 50
0 1

CLIENT / SERVER
2 Back-up server

Client Server / Workstation

SPEC 135

PORT NUMBER

* Enter number from 1 to 254

43

SM100 6.5 WIRE CONFIGURATION

INTERFACE

6.5.1 Ethernet Wire - Straight Cable and Crossover Cable Straight cable is for Client / Server connection. Crossover cable is for Hub to Hub connection. (Some models of the hub do not need crossover cable for hub to hub connection. Please refer to the hub operation manual if in doubt) Telephone Modular Plug (Category 5) -

Preferable type : CABLE TYPE Cable type :

CviLux CJP3 / CviLux CJP4 (with insert bar)

4 pair 100MHz Cat.5 AWG 24 or 26 UTP / FTP / STP. Cat. 5 AWG 24 or 26 FTP / Cat. 5 AWG 24 or 26 STP (Recommended for CISPR 22B conformance)

Preferable type :

PIN CONFIGURATION 1 SM 100 8 Solder to braid wire of the Ethernet wire if using plug without insert bar 1 SM 100 8 Solder the braid wire of the Ethernet wire if using plug with insert bar 1 CROSSOVER CONNECTION HUB
PIN SIGNAL 1 TX+ 2 TX3 RX+ 6 RX5,7,8 N.A.

8 HUB 1

8 HUB

STRAIGHT CONNECTION SCALE


PIN SIGNAL 1 TX+ 2 TX3 RX+ 6 RX5,7,8 N.A.

HUB
SIGNAL PIN TX+ 1 TX2 RX+ 3 RX6 N.A. 5,7,8

HUB
SIGNAL PIN TX+ 3 TX6 RX+ 1 RX2 N.A. 5,7,8

44

SM100 6.5.2 RS232C Wire PC (9 PIN) TO SCALE RS232C PORT

INTERFACE

RS232C Port9 Pin RS-232

PC COM Port9 Pin PC Not used TXD RXD Not used GND Not used Not used Not used Not used Pin 1 2 3 4 5 6 7 8 9

Pin 1 2 3 4 5 6 7 8 9

Not used RXD TXD DTR GND DSR DTR DSR Not used

6.5.3 Cash Drawer Connector


SM-100 uses normal phone mike plug to connect cash drawer and the scale.
1 pin 4 pin 1 pin 4 pin

Plug in the scale Pin Output 1 Not used. 2 +8V 3 GDD 4 Not used.

Connector of Cash Drawer Input Pin Not used 1 Voltage + 2 GDD 3 Not used 4

45

SM 100

MISCELLANEOUS

7.
7.1

MISCELLANEOUS
MODE CHANGE

To toggle between R, X, S, Z and Password mode.


OPERATION DISPLAY PT 0.000 [MODE],[MODE] (within 3 seconds) [MODE] [MODE] [MODE] [MODE] 0.000 S1 Z1.0 RESET PWD X 0.000 PLU SALES 0 0.00 kg 0.000 /kg 0.00 0.00 XMODE FILE DAILY SET 0.00 REMARK Weight mode.Lamp R turns on. Enter X mode.Lamp X turns on. Enter S mode.Lamp S turns on. Enter Z mode.Lamp Z turns on. Enter Password Set mode.Lamp X flicker Back to Weight mode.Lamp R turns on.

** The X mark on the X, S, Z and R mean the indicator light is on. When in Passwomode, indicator light will be blinking.

the

7.2

SPAN SWITCH STATUS


DISPLAY PT Z1.0 kg RESET STE16 Z1.0 RESET /kg SALES VX.XX SALES DAILY S-OFF DAILY Z mode. Lamp Z turns on. Enter [2][8][4] while depressing [Rezero]. Exit after 3 seconds.

To check the status of the span switch.


OPERATION REMARK

Go to Z mode [Rezero]+[2][8][4]

7.3

CLEAR ALL PLU DATA


DISPLAY PT Z1.0 kg RESET CLEAR CLEAR Z1.0 RESET /kg SALES PLU PLU SALES DAILY FILE Y--C N--T DAILY Z mode. Lamp Z turns on. Enter [2][3][0] while depressing [Rezero]. Enter C for Yes, Enter T for No.. Back to Z mode

To clear all the PLU data only, the span switch status must be on.
OPERATION REMARK

Go to Z mode [Rezero]+[2][3][0] * C(T)

7.4

THERMAL HEAD USAGE


46

SM 100

MISCELLANEOUS

To check how many time the thermal head had been printing.
OPERATION DISPLAY PT Z1.0 kg RESET PRINTER Z1.0 RESET /kg SALES USAGE SALES DAILY 5 DAILY Z mode. Lamp Z turns on. Display thermal printer usage condition(meter). [T] key to exit. REMARK

Go to Z mode
[Rezero]+[0][8][2][3] [T]

7.5

IP ADDRESS

To check and modify the scale IP address.


OPERATION DISPLAY PT Z1.0 SCALE SCALE kg RESET IP IP /kg SALES 19216800 19200910 DAILY 0000 0000 ---------Z mode. Lamp Z turns on. Display the scale IP address. Modify the IP address. Save the new IP address. Press [T] key to exit. REMARK

Go to Z mode
[Rezero]+[0][4][1][6] [1][9][2][0][0] [9][1][0] [0] [#]

7.6

SERVER IP ADDRESS

To check and modify the server IP address.


OPERATION DISPLAY PT Z1.0 SERVER SCALE kg RESET IP IP /kg SALES 25525525 19200910 DAILY 5000 0000 ---------Z mode. Lamp Z turns on. Display the server IP address. Modify the server IP address. Save the new IP address. Press [T] key to exit. REMARK

Go to Z mode
[Rezero]+[0][4][1]7] [1][9][2][0][0] [9][1][0] [0] [#]

7.7

SUBNET MASK
47

SM 100 To check and modify the subnet mask.


OPERATION DISPLAY PT Z1.0 SERVER SCALE kg RESET IP IP /kg SALES 25525525 19200910 DAILY 5000 0000 ----------

MISCELLANEOUS

REMARK Z mode. Lamp Z turns on. Display the server IP address. Modify the server IP address. Save the new IP address. Press [T] key to exit.

Go to Z mode
[Rezero]+[0][4][1]8] [1][9][2][0][0] [9][1][0] [0] [#]

7.8

MAC ADDRESS

To check the MAC address. Please turn on the span switch before proceed.
OPERATION DISPLAY PT kg /kg DAILY Z mode. Lamp Z turns on. Display the MAC address. Press [T] key to exit. REMARK

Go to Z mode

Z1.0
ETHERN ET Z1.0

RESET

SALES

[Rezero]+[0][6][1]2] [T]

0006C071 RESET SALES

96BE DAILY

7.9

SERIAL NO

To check the serial NO..


OPERATION DISPLAY PT Z1.0 kg RESET SCALE Z1.0 RESET /kg SALES S/N SALES DAILY 05386686 DAILY Z mode. Lamp Z turns on. Display the serial NO.. Press [T] key to exit. REMARK

Go to Z mode
[Rezero]+[1][1][1] [T]

8.0 ASCII CHARACTER Below are the common use of characters of ASCII code in HEX value. Please enter the hex value when entering commodity name, advertisement, shop name, clerk name, special message, ingredient, text etc. when using the SM-100.
A B C D E F G
48

SM 100
41 N 4E a 61 n 6E 0 30 $ 24 > 3E 42 O 4F b 62 o 6F 1 31 % 25 = 3D 43 P 50 c 63 p 70 2 32 ^ 5D / 2F 44 Q 51 d 64 q 71 3 33 & 26 ? 3F 45 R 52 e 65 r 72 4 34 * 2A 2E 46 47 48 S T U 53 54 55 f g h 66 67 68 s t u 73 74 75 5 6 7 35 36 37 : ( ) 28 29 3A Space , 2C 20 49 V 56 i 69 v 76 8 38 ; 3B 4A W 57 j 6A w 77 9 39 " 22 4B X 58 k 6B x 78 ! 21 ' 27

MISCELLANEOUS
4C Y 59 l 6C y 79 @ 40 + 2B 4D Z 5A m 6D z 7A # 23 < 3C

49

Specification List

SM-100 V2.00

26 December, 2006

TITLE REVISION NO. ISSUED DATE


Rev. No. 0

: : :

SM-100 SPECIFICATION LIST 0 17 August, 2004


Modification Details Software Version 1.00

First Release

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

1 of 32

Specification List SPEC NO.

SM-100 V2.00

26 December, 2006

SPECIFICATION DESCRIPTION

SM-100

CUSTOMER SPECIFICATION [REZERO] + [1][4][1]


00 Item Barcode 0 F1F2 CCCCC XCD XXXX CD 1 F2 CCCCCC XCD XXXX CD 2 F1F2 CCCCC 0 XXXX CD 3 F1F2 CCCCCC XXXX CD 4 F1F2 CCCCC XXXXX CD 5 F2 CCCCCC XXXXX CD 6 F2 CCCCC XXXXXX CD 7 F1F2 CCCCCCCCCC CD #1 8 F1F2 CCCC XXXXXX CD 9 F1F2 CCCCC CD #2 10 F2 CC XXXX CD #3 11 No Barcode 12 F1X2 CCCCC XCD XXXX CD Right Side Data of Item Barcode 0 Quantity 1 Price 2 Weight 3 User Programmable # Right Side Price Data of Item Barcode 0 Price before Tax 9 13 14 15 16 17 18 19 20 F1X2 CCCCCC XXXX CD F1F2 CCCC XCD XXXXX CD F2 CCCCC XCD XXXXX CD F1F2 CCC XXXXXXX CD F1F2 CC XXXXXXXX CD CCC WWWW PPPPP CD No Barcode F1F2 CCCCC PCD XXXX CD
All are 13 digits non-PLU barcode unless otherwise stated. #1 13 digits PLU barcode #2 8 digits PLU barcode #3 8 digits non-PLU barcode

01

9 4 5 6 7 1 Original Price Weight / Quantity Unit Price Unit Price after discount Price after Tax
# Related to SPEC153.

02 03 04 05 06 07

9
Effective when SPEC1 = 1

08

09 10 11

Flag Data F1 and F2 for 13 Digits Non-PLU Barcode Enter value from range 0 to 99 Flag Data F1 and F2 for 13 Digits PLU Barcode Enter value from range 0 to 99 Flag Data F2 for 8 Digit Non-PLU Barcode Enter value from range 0 to 9 Flag Data F1 and F2 for 8 Digit PLU Barcode Enter value from range 0 to 99 Total Barcode 0 F1F2 CCCCC XCD XXXX CD 12 F1X2 CCCCC XCD XXXX CD 1 F2 CCCCCC XCD XXXX CD 13 F1X2 CCCCCC XXXX CD 2 F1F2 CCCCC 0 XXXX CD 14 F1F2 CCCC XCD XXXXX CD 3 F1F2 CCCCCC XXXX CD 15 F2 CCCCC XCD XXXXX CD 4 F1F2 CCCCC XXXXX CD 16 F1F2 CCC XXXXXXX CD 5 F2 CCCCCC XXXXX CD 17 F1F2 CC XXXXXXXX CD 6 F2 CCCCC XXXXXX CD 18 CCC WWWW PPPPP CD 7 F1F2 CCCCCCCCCC CD #1 19 No Barcode 8 F1F2 CCCC XXXXXX CD 20 F1F2 CCCC PCD XXXX CD 9 F1F2 CCCC CD #2 10 F2 CC XXXX CD #3 11 No Barcode Left Side Data of Total Label 0 Scale No. 3 Clerk No. 1 Last Accumulated Item Code 4 Fixed No. 2 Receipt No. Fixed Data for Left Side Data of Total Barcode Enter value from range 0 to 9 999 999 999 Flag Data F0, F1 and F2 for Total Barcode Enter value from range 0 to 999 Right Side Data of Total Barcode 0 Quantity 2 Weight 1 Price Total Barcode Print on Receipt 0 No 1 Yes Print Readable Character of F1 for Item and Total Barcode (for EAN only) 0 No Print 1 Print Printing Position for Advertisement Message 0 First Line 2 Above 1 Below 3 Not Used Turnover Printing for Advertisement Message 0 No 1 Yes

9 9 9 9 9
All are 13 digits non-PLU barcode unless otherwise stated. #1 13 digits PLU barcode #2 8 digits PLU barcode #3 8 digits non-PLU barcode

9 9 9

12 13 14 15 2
nd

9 8

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

2 of 32

Specification List 16

SM-100 V2.00 9

26 December, 2006

17 18 19

20 21 22 23 24

25

26 27 28 29 30 31 32

Exit from Change Mode within Specified Interval 0 No 3 10 sec 1 3 sec 4 15 sec 2 6 sec Order of the Month, Day and Year for Print 0 MM/DD/YY 2 YY/MM/DD 1 DD/MM/YY 3 Not Used 1 or 2 Line(s) Commodity Name on Receipt 0 2 Lines 2 No Print 1 1 Line Label Printing by Clerk Key 0 No Print 2 Print without Accumulated 1 Print with Accumulation Total Label Printing 0 No Print 1 Print Printing Operator Name on Receipt and Label 0 Code 1 Name Receipt Paper Width 0 60 mm 2 50 mm 1 40 mm Manual Price Entry for Printing or Accumulating 0 Allow 1 Inhibit Default Label Format for Item Printing 0 T1 (A) 12 S (T7) 1 T2 (B) 13 A (T8) 2 T3 (C) 14 B (T9) 3 T4 (U2) 15 C (T10) 4 T5 (U3) 16 F1 (F1) 5 T6 (U4) 17 F2 (F2) 6 T7 (U5) 18 F3 (F3) 7 T8 (U6) 19 F4 (F4) 8 T9 (U7) 20 F5 (F5) 9 T10 (U8) 21 F6 (F6) 10 T11 (T5) 22 F7 (F7) 11 T12 (T6) 23 F8 (F8) Default Label Format for Total Printing 0 T1 (A) 12 S (T7) 1 T2 (B) 13 A (T8) 2 T3 (C) 14 B (T9) 3 T4 (U2) 15 C (T10) 4 T5 (U3) 16 F1 (F1) 5 T6 (U4) 17 F2 (F2) 6 T7 (U5) 18 F3 (F3) 7 T8 (U6) 19 F4 (F4) 8 T9 (U7) 20 F5 (F5) 9 T10 (U8) 21 F6 (F6) 10 T11 (T5) 22 F7 (F7) 11 T12 (T6) 23 F8 (F8) Shop Name Printing on Label 0 No Print 1 Print Forced Tare Function 0 Disable 1 Enable Peel Sensor Function in Prepack Mode 0 Disable 1 Enable Continuous Print for Label in Prepack Mode 0 Inhibit 1 Allow Selection of CDV 0 Inhibit 1 Allow CDV Type 0 CDV 1 Tear-off CDV Modulus 0 Modulus 10 1 Modulus 11 On Spot Correction 0 Allow Search Correction 0 Allow Move Back Correction 0 Allow

9 9 8

9 9
Formats in ( ) are for U1 and CA only. F1 to F8 are Free Format.

9
Formats in ( ) are for U1 and CA only. F1 to F8 are Free Format.

9 9 9 9 8
For SF only.

8
For SF only.

8
For SF only. Effective when SPEC30 and 31 = 1.

33 34 35

9 1 1 1 Inhibit 8 Inhibit 9 Inhibit 3 of 32

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

Specification List 36 Past Sales Data Correction 0 Allow 37 Label Print Density 0 Low 1 Mid 38 Receipt Print Density 0 Low 1 Mid 39 40 41 42 43 44 45 46 47 48 49

SM-100 V2.00 1 2 3 2 3 Inhibit 9 High-mid High 9 High-mid High 9

26 December, 2006

Calling of PLU 0 Manual 2 Time-out 1 Auto PLU Digits for Auto PLU Calling/Time-out Calling 0 3 Digits / 0.5 sec 2 5 Digits / 1.5 sec 1 4 Digits / 1.0 sec 3 6 Digits / 2.0 sec Unit Price of Weigh PLU Can Use for Price of Non-weigh PLU and Vice Versa 0 Allow 1 Inhibit Unit Price Override 0 Allow 1 Inhibit Main Usage for Commodity Name, Shop Name and Special Message 0 Receipt 1 Label Tare Override 0 Allow 1 Inhibit Item Printing 0 Allow 1 Inhibit Default Data of Printing Shop Name Number for Label Enter value from range 0 to 32 Default Data of Printing Shop Name Number for Receipt Enter value from range 0 to 32 Setting of Scale Number Enter value from range 0 to 999 999 Type of Client / Server Interface 0 No Interface 3 Not Used 1 Ethernet (Coaxial Cable) 4 4-Lines (RS-485) 2 Ethernet (Twisted Pairs) Setting of Client / Server 0 Client 2 Backup Server 1 Server / Workstation

Related to SPEC40.

9
Effective when SPEC39 = 1.

9
Effective when SPEC643 = 0.

9 9
Always set to 0 for SM200.

9 9 9 9 9 9
Related SPECs for Ethernet I/F are SPEC50, 135, 214.

50

9
Related SPECs for S/C setting are SPEC61, 150, 163, 165, 187, 194, 208, 229, 252, 253, 254, 255, 265, 276.

51

Baud Rate of SIO (RS-232C Port) 0 1 200 bps 1 2 400 bps 2 4 800 bps 3 9 600 bps Data Length of SIO (RS-232C Port) 0 7 Bits Parity Bit of SIO (RS-232C Port) 0 None 1 Odd Stop Bit of SIO (RS-232C Port) 0 1 Bit

9 4 5 6 19 200 bps 38 400 bps 76 800 bps


Apply to both RS-232C and RS-485 ports setting for SM-300. Related SPECs are SPEC48, 52, 53, 54, 60, 134.

52

9 1 8 Bits
Apply to both RS-232C and RS-485 ports setting for SM-300.

53

9 2 Even
Apply to both RS-232C and RS-485 ports setting for SM-300.

54

9 1 2 Bits
Apply to both RS-232C and RS-485 ports setting for SM-300.

55

56 57

58

Baud Rate of Multi-drop SIO (RS-485 / 4-Lines Port) 0 1 200 bos 3 9 600 bps 1 2 400 bps 4 19 200 bps 2 4 800 bps 5 38 400 bps Data Length of Multi-drop SIO (RS-485 / 4-Lines Port) 0 7 Bits 1 8 Bits Parity Bit of Multi-drop SIO (RS-485 / 4-Lines Port) 0 None 2 Even 1 Odd Stop Bit of Multi-drop SIO (RS-485 / 4-Lines Port) 0 1 Bit 1 2 Bits

8
Related SPECS are SPEC48, 56, 57, 58, 59, 134.

8 8

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

4 of 32

Specification List SM-100 V2.00 59 Multi-drop SIO (RS-485 / 4-Lines Port) Select Job 0 No Operation 2 Pick N Pay #2 1 FIS 3000 #1 60 SIO (RS-232C Port) Select Job 0 No Operation 1 FIS 30000 #1 2 FL-1

26 December, 2006 8
#1 Either SPEC59 or 60 can be selected at any one time. #2 For SF only.

8 3 4 5 Point N Shop Barcode Scanning Video Control #2


Apply for both RS-232C and RS-485 ports setting for SM-300. #1 Refer to SPEC59s comments #1. #2 For SM-300 only

61 62 63 64 65

Floating Clerk 0 Inhibit 1 Allow Receipt Free Format 0 Disable 1 Enable SM-90 and DI-10 RS-232C Communication 0 No 1 Yes Enable Password Mode 0 Allow 2 Allow Multi Password 1 Inhibit Report Printing in Daily and Term Transaction Clear 0 Inhibit 1 Allow

8 8
Exclude AA.

8 9

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

5 of 32

Specification List SM-100 V2.00 66 Pack Quantity Function Key Enable 0 Allow 1 Inhibit 67 Advertisement Function Key Enable 0 Allow 1 Inhibit 68 Fixed Total Price Discount Function Key Enable 0 Allow 1 Inhibit 69 Total Price Percentage Discount Function Key Enable 0 Allow 1 Inhibit 70 Fixed Unit Price Function Key Enable 0 Allow 1 Inhibit 71 Fixed Unit Price Percentage Function Key Enable 0 Allow 1 Inhibit 72 Pack Date Function Key Enable 0 Allow 1 Inhibit 73 Minus Pack Date Function Key Enable 0 Allow 1 Inhibit 74 Sell by Date Function Key Enable 0 Allow 1 Inhibit 75 Unit Symbol Function Key Enable 0 Allow 1 Inhibit 76 Quantity Set Function Key Enable 0 Allow 1 Inhibit 77 Price Change Function Key Enable 0 Allow 1 Inhibit 78 Refund Item Function Key Enable 0 Allow 1 Inhibit 79 Shop Name Function Key Enable 0 Allow 1 Inhibit 80 Logo Function Key Enable 0 Allow 1 Inhibit 81 Print Select Function Key Enable 0 Allow 1 Inhibit 82 Print of Place of Production on Label 0 Inhibit 1 Allow 83 Selection of Markdown 0 No Markdown 2 Total Price Markdown 1 Unit Price Markdown 3 Unit and Total Price Markdown 84 Sub-total Function Key Enable 0 Allow 1 Inhibit 85 Grand Total Function Key Enable 0 Allow 1 Inhibit 86 Label Sensor Gap Value Enter value range from 0 to 255 87 Label Type 0 Gap 1 No Gap 88 Sell by Date Title Print out 0 Inhibit 1 Allow 89 ASCII Code Entry in S Mode 0 Inhibit 1 Allow 90 91 92 Sub-total Markdown 0 No Markdown 1 Printer Speed for Receipt 0 Slow 2 1 Normal Printer Speed for Label 0 Slow 2 1 Normal Printer Strode 0 Single 2 1 Double Print Second Receipt 0 No Print 3 1 Continuous Print 4 2 1 sec Delay Position of Currency Symbol (on Label) 0 Before Price 1 Receipt Printing with Dual Copy 0 Inhibit 1 Advertisement Message on All Label 0 Inhibit 1 Manual Print in Prepack Mode for Weigh Item Markdown

26 December, 2006 9 9 9 9 9 9 9 9 9

9 9 9 9 9 9

9 9 8 9 8
For AA only.

8
For AA only.

9 9 High 9 High 8 Not Used 9 3 sec Delay User Select 9 After Price 8 Allow 9 Allow 9 6 of 32

93

94 95 96 97 2
nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

Specification List SM-100 V2.00 0 Inhibit 1 Allow 98 Quantity and Unit Symbol Print Out for Non-weigh Item in Manual Mode 0 Allow 1 Inhibit 99 Unit Print Out for Non-weigh Item in Manual Mode 0 Inhibit 1 Allow 100 Discount in PLU Programming 0 Allow 1 Inhibit 101 Zero Suppress for Date and Time 0 Disable 1 Enable 102 Discount Presentation in Receipt 0 Discounted Unit Price and 1 Original Unit Price and Price Original Price 103 Unit Price Assignment Function Key for PLU 0 Enable 1 Disable 104 Discount Price Rounding Method 0 Rounding 2 Cut Up 1 Cut Down 105 Fixed Total Price Markdown Function Key Enable 0 Allow 1 Inhibit 106 Total Price Percentage Markdown Function Key Enable 0 Allow 1 Inhibit 107 Fixed Unit Price Markdown Function Key Enable 0 Allow 1 Inhibit 108 Fixed Unit Price Percentage Markdown Function Key Enable 0 Allow 1 Inhibit 109 Source of Sell by Date 0 Real Time Clock 1 Packed Date 110 Year Type 0 Standard 1 Japanese / Taiwan 111 Price Symbol on Receipt 0 No Print 2 Yen 1 Kanji Yen 112 Default Data of Printing Special Message Number for Receipt Enter value range from 0 to 16 113 Label Logo Printing Status 0 No Print 3 Logo 3 1 Logo 1 4 Logo 4 2 Logo 2 114 Receipt Logo Printing Status 0 No Print 4 Logo 3 1 Logo 1 5 Logo 4 2 Logo 2 6 Logo 1, 2, 3 and 4 3 Logo 1 and 2 115 Type of Entry for Used by Date and Sell by Date 0 By Day 1 By Hour 116 Barcode Printing in First Label for Dual Label Printout 0 Print 1 No Print 117 Zero Minutes Printing 0 No Print 1 Print 118 119 Both Price before and after Discount 0 Price before and after Discount Unit Symbol Printout in Receipt 0 Depend on PLU Programming 1 Japanese PCS PLU Number Print 0 No Zero Suppress Thick Japanese Character Printout 0 Thick Character Prepare Mode after Power On 0 Manual Mode Printing Thank You Message on Receipt 0 Enable PLU Unit Price after Discount 0 Unit Price after Discount Position of Special Message on Receipt 0 Bottom Function Keys Protection for Self-service 0 No Protection 1 Full Protection Printing of Checksum for Item Barcode 1 2 Price before Discount only No Print

26 December, 2006 9 8 8 9 8

9 9 9 9 9 8
For AA and TW only.

8
For AA only.

9 9

8
For NICHII only.

8
For NICHII only.

8
For NICHII only.

8
For NICHII only.

9
For AA only.

120 121 122 123 124 125 126 127 2


nd

9 1 1 1 1 1 1 2 Zero Suppress 8 Thin Character Prepack Mode Disable 9 Unit Price Discount Amount 9 Top 8 Partial Protection
For AA only.

8
Always set to 0 for SM200.

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

7 of 32

Specification List SM-100 V2.00 0 Disable 1 Enable 128 Setting of Host Number (For SM-15 Multi-drop) Enter value between 0 to 99 129 Type of Host to be Communicated 0 Standalone 2 POS ECR 1 TMR ECR 130 Selection of Print Item on Prepack Total Label 0 Based on Status on Item Label 1 Based on Status on Manual Total Label 131 Print PLU Setting Quantity in Manual Mode 0 No 1 Yes 132 133 134 Receipt Total Report 0 No 1 Yes Change All PLU Default Format when Default SPEC Change 0 Yes 1 No Host Communication 0 No Operation 1 Enable Host Communication 0 RS-232C 1 RS-485 Port Number Enter value from range 1 to 254 One or Two Touch for Self-service Operation 0 One Touch 1 Two Touches Centering of Ingredient Data 0 Yes 1 No Permanent Price or Discount Price Change via Function Key 0 No Update to PLU 1 Update to PLU Number of Digits for Teraoka Code 0 2 Digits 1 3 Digits AA Message Size 0 24 x 24 1 16 x 16 Year Format 0 YY 1 YYYY Selection of Day Display for Sell by Date 0 Disable 1 Enable Peel Sensor Trigger Voltage 0 High 1 Low Display Prepack Quantity Balance 0 Enable 1 Disable Print Select Function Across the Board 0 Disable 1 Enable Label Format 1, 2 Function Key Enable 0 Inhibit 1 Allow Prepack Non-add Function Key Enable 0 Inhibit 1 Allow FIS3000 Code 0 SM-80/90 FIS3D 1 SM-25 FIS3D Main Group Function Key Enable 0 Inhibit 1 Allow Preset Key Assignment for Client 0 Local Assign 1 Central Assign Change Sell by Date or Used by Date when Packed Date Changed 0 No 1 Yes Sell by Date or Sell by Time for Individual PLU 0 Disable 1 Enable User Programmable Right Side Data for Item Barcode 0 With Identification Digit 1 Without Identification Digit Keysheet Letter Size 0 Small Letter 1 Capital Letter Test Print on Receipt 0 No Print 1 Print Image Copy from Free Format 0 Disable 1 Enable Training Mode 0 Disable 1 Enable FSD Price and Image 0 Disable 1 Enable and Key Function 0 Disable 1 Enable Twisted Pair Cable for Ethernet

26 December, 2006 8
For IR only.

8
For IR only. Use with SPEC128.

9 9
Effective when SPEC98 = 0.

8 For DM only. 9 8

135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 2
nd

9 9 9 9 8 8
For AA only.

9 9 8 8 9 9
Exclude AA. Exclude AA.

Exclude AA.

9 8
For FL & AS only.

8
For SD only.

9 8
Exclude DEC.

8
For U1 only.

8 8 8 of 32

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

Specification List SM-100 V2.00 0 Shield 1 Unshielded 161 Discount Label Format 0 Enable 1 Disable 162 Item Code Function Key Enable 0 Enable 1 Disable 163 Transaction Data Store in Client Memory 0 Disable 1 Enable 164 Maximum Label Length 0 120 mm 1 240 mm 165 Update Report for Client / Server System 0 Yes 1 No 166 Average Price and Weight Label Function 0 Disable 1 Enable 167 Label Date Title Print 0 No Print 1 Print 168 GB Code 0 GB Code 1 Shift GB Code 169 Print PLU Setting Unit in Manual Mode 0 No 1 Yes 170 User Specification (REZERO + 141) Accessible from Z Mode Only 0 No 1 Yes 171 Euro Mode 0 Disable 1 Enable 172 Dual Declarations 0 No 1 Yes 173 Mask 7-segment Display in X, S and Z Mode 0 No 1 Yes 174 175 176 177 178 179 180 181 182 183 Fixed Clerk Assign to Preset Key 8, 16, 24 and 32 0 Clerk Keys 1 Function Keys 30 lb to 15 kg Conversion 0 Disable 1 Enable Discount Time on Daily Basis 0 No 1 Yes Weight Check Function 0 No 1 Yes Unit Price Override per PLU 0 No 1 Yes Black Bar Sensing Label 0 Normal 1 Black Bar Sensing Scroll Message Group 0 Disable 1 Enable Continuos Label 0 Disable 1 Enable Character Size for Barcode Data 0 Large 1 Small PLU Clear after 10 seconds Time-out 0 No 1 Yes Duplicate Unit and Total Price on Label 0 No Print

26 December, 2006
Not in used.

8
For SD only.

9 9
Exclude AA.

8
For CN and MS only.

8 9 9
For U1 only.

8
For double display types only.

8
For bench type only.

8
For UK only.

9 8 9 9

9 9 8

184

8 1 Print
Effective when SPEC158 = 1.

185 186 187 188 189

Weigh PLU Can Use for Non-weigh PLU and Vice Versa Function Key Enable 0 Disable 1 Enable Print $ and Weight Unit on Label 0 No Print Clear Total Data by Server 0 Both Server and Client 9 1 1 Print Server 8

Tare Decimal Point Left Shift for SM-25 FIS3D 0 No 1 Yes PLU Auto Delete 0 No Delete 1 15 Days Swap Weight and Unit Price on Receipt 0 No 2 3 1 30 Days 90 Days

190
nd

8 Yes 9 of 32

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

Specification List 191 192

SM-100 V2.00 9 Yes 8 3 4 5 Standard Condensed Tabulated Tabulated Extra Condensed

26 December, 2006

Default Item Code Equals to PLU Number 0 No 1 Nutrition Template 0 Standard 1 Simplified 2 Simplified Condensed Nutrition Adjustment Feed Enter value from range 0 to 255 Server IP Address Enter a value between 1 to 254

For U1 and CA only.

193 194

9
For U1 and CA only.

9
For Client scale only.

195 196 197

198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217

Weight Print for Non-weigh Item 0 No 1 Yes Scale File 0 Disable 1 Enable Print Format of Month 0 Number 2 3 Alphabetic 1 2 Alphabetic FSD Saving Calculation 0 Net Value 1 Cent Off FIS3000 Time Out 0 2 sec 2 32 sec 1 8 sec PLU Call Up Range 0 Disable 1 Enable Sell by Date for Manual Mode 0 Programmed Sell by Date 1 Zero Sell by Date Printing of Item Label when Barcode Data Overflow 0 Print 1 No Print Preset Keys Pages 0 1 Page 2 3 Pages by Shift Key 1 3 Pages by Toggle Reference PLU Function Key Enable 0 Inhibit 1 Allow Print Function Key Enable 0 Inhibit 1 Allow Print Barcode when Right Side Data Overflow 0 No print 1 Print Barcode Digits Weight Decimal Point Position for Barcode and Label Printing 0 Same as SPEC607 1 0.000 Network Time Out 0 3 sec 1 x2 FSD Calculation 0 Unit Price 2 3 1 x4 x10

8
For U1 only.

9 9

8
Effective when SPEC607 = 2.

8 Price Percentage Off


For U1 only.

218 2
nd

PLU Repeat Function Key Enable 0 Inhibit 1 Allow Pick N Pay Protocol 0 Old 1 New Department Number for Pick N Pay Enter a value between 1 to 99 Flag Code Function Key Enable 0 Inhibit 1 Allow DHCP Function 0 Disable 1 Enable Centering of Special Message 0 Yes 1 No JIS Code Table 0 New 1 Old Default Label Format 2 for Item Printing 0 Not Used 5 F5 1 F1 6 F6 2 F2 7 F7 3 F3 8 F8 4 F4 Zero Unit Price for Unit Price Change Function Key

8
For SF only.

8
For SF only.

9 8
For AA only.

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

10 of 32

Specification List SM-100 V2.00 0 Inhibit 1 Allow 219 Numeric Key Entry Reset 0 3 sec 2 Disable 1 5 sec 220 Item Barcode Right Side Data Dependent on Unit 0 Disable 1 Enable 221 222 223 224 225 226 227 228 229 230 231 232 233 Receipt with Tax Information Function Key Enable 0 Inhibit 1 Allow Open Cash Drawer without Sales Function Key Enable 0 Inhibit 1 Allow Negative Unit Price Function 0 Disable 1 Enable FIS3000 Wire Type 0 4 wires 1 2 wires Prepack Grand Total for Individual PLU 0 Yes 1 No Reverse Calculation of ITF Check Digit 0 No 1 Yes Unit Price Override Password Function 0 Inhibit 1 Allow Individual PLU Total Transaction 0 No Preset Key Group 0 Disable 1 1 Yes Enable

26 December, 2006 9
For AA only.

8
Effective when SPEC1 = 0 or 2.

8 9 8 8

Effective when SPEC178 = 1.

Effective when SPEC150 = 1.

Auto Print after PLU Call 0 No 1 Yes Zero Unit Price for PLU and Unit Price Override 0 Inhibit 1 Allow Feed for Continuous Label 0 No 1 Yes Time Format 0 24 Hours 1 12 Hours (AM/PM)

9 9 9 9

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

11 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 234 235

SPECIFICATION DESCRIPTION Sub-total and Grand Total Barcode 0 Based on Item Barcode 9 1 Based on Total Barcode 9

SM-100

Mask Barcode Last Human Readable Check Digit 0 No 1 Yes Character Generator for Korea 0 Old Half-key Function 0 Inhibit FIS3000 Free Format Unit 0 mm 1 Dots

236 237 238

8 1 1 2 New Allow 9 SM-25 Dots 9 Allow Allow 7 Digits Allow 8 1 1 Yes Yes 9
For KE only.

239 240 241 242 243 244 245 246 247

Cheque and Credit Payment Function Key 0 Inhibit 1 Voucher Payment Function Key 0 Inhibit PLU Code for IR POS and TMR 0 6 Digits Discount without Limit Function Key 0 Inhibit Concatenate Commodity Name Display 0 No Enable PLU Price Change Flag 0 No 1 1 1

Print Sell by Date or Used by Date when Date Equals Packed Date 0 Yes 1 No Print First and Check Digits Outside Barcode 0 No 1 Print Packed date 0 Manual and Prepack Mode 1 Manual Print Sell by Date 0 Manual and Prepack Mode 1 Manual Mode Print Used by Date 0 Manual and Prepack Mode 1 Manual Mode Centering Shop Name on Label 0 No Shop Name on Receipt 0 Top Auto Reconnect when Server Down 0 Disable 1 Every 2 min 2 3 2 3 2 3 1 1 2 3 Yes

9 9 Prepack Mode No Print 9 Prepack Mode No Print 9 Prepack Mode No Print 9 Yes 9 Bottom Every 3 min Every 15 min

248

249

250 251 252

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

12 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 253

SPECIFICATION DESCRIPTION Client Auto PLU Update 0 Update / Delete Existing PLU 1 Update / Delete All Sever PLU 2 Update Existing PLU Auto Update of Client Off-line Report 0 Disable Retry Ethernet Communication 0 2 times

SM-100

3 4

Update All Server PLU Disable

254 255

1 1

Enable 5 times 8 No Yes Yes 9 Yes 9 Name Enable 8 Receipt


Always set to 1 for SM200. For AA only.

256 257 258 259 260 261 262

Display Price with Tax after Clerk Key Press 0 Yes 1 Change Place Name to PLU via Function Key 0 No 1 Beef Labeling 0 No Auto Print Sub-total Label in Prepack 0 No Beef Labeling : Print Country 0 Code External Rewinder 0 Disable Selection of Receipt / Label 0 Label FSD Net Value Minimum 0 Off Print Ingredient Data on Next Label 0 Disable Client Using Local Free Format Label 0 No FSD Weight 0 Back Computed (Single Range) 1 Back Computed (Dual Range) CPDL Language Selection 0 First Language 1 1 1 1 1

For AA only.

263 264 265 266

8 1 1 1 2 On Enable Yes 8 Exact Weight


For U1 only. For U1 only.

267 268

8 1 Second Language
Exclude AA, HK, CN, TW and KE.

Display Special Scale Message for Discounted Item 0 No 1 Yes Auto Clerk Accumulation (for scanner) 0 No 1 V1 2 V2 3 V3

269

9 4 5 6 7 V4 V5 V6 V7 Auto Clear
For IR only.

270

Individual Report Print and Clear in Z Mode 0 Disable 2 1 Manual Clear Store Total Report Clear 0 Store Total Report Only 1

271

All Report

Effective when SPEC270 = 1 or 2.

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

13 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 272 273 274 275 Beef Reference Number 0 Code

SPECIFICATION DESCRIPTION 9 1 1 1 1 Date 9 No 8 Old 8 Enable

SM-100

Item Code Follow PLU Number 0 Yes Bench Key Pad 0 New Taiwan Receipt Printer 0 Disable

For TW only. Apply for POS1 FLEX PP2000 srs. 2 only.

276 277

Floating Server 0 Disable Real Time Buffer 0 No 1 2 Days 2 3 Days 3 4 Days Traceability Report 0 Disable 1 By Reference No. 2 By PLU No. U1 Self-service 0 Disable Real Time Customer Number 0 No Real Time Buffer Receipt 0 Detail Barcode Function 0 Without CR Barcode Look-up-table (LUT) Contents 0 Non-weigh Item Only Open Cash Drawer on Credit Payment 0 Allow Australia ECR Function 0 No Enforce Amount Tendered 0 No Enforce Change Key 0 No Planned Price Printed in Report 0 Enable Repeat PLU Call 0 No Payment Key 0 Disable

1 4 5 6 7 3 4

Enable 9 5 Days 6 Days 7 Days Unlimited 9 By Date and Reference No. By Date and PLU No. 8

278

279 280 281 282 283 284 285 286 287 288 289 290

1 1 1 1 1 1 1 1 1 1 1 1

Enable Yes

For U1 only.

8 Total Only 8 With CR 8 All Items 9 Inhibit 8 Yes Yes 9 Yes Disable Yes 8 Enable
For DEC countries only. For AR only.

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

14 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 291 292 293

SPECIFICATION DESCRIPTION Gap Value In-feed Operation 0 Re-adjustable SM-200 Power Save 0 Back Light Off SM-200 Power Save Timeout 0 3 Min 1 5 Min PLU Scrolling Message Display Interval 0 Disable 1 3S 2 10S 3 30S SM-200 Battery Option 0 Yes SM-300 Scrolling Message Update Rate 0 6 Lines Ingredient File-Size Expansion 0 Maximum 99 records Print PLU Ingredient in Receipt 0 No Traceability Update Function 0 No Keyboard Selection 0 Normal Keyboard # 1 100 Preset Keys SM-500 Self-Service 0 No Print Receipt after Accumulation 0 Yes Fixed Port Number for Ethernet Enter value from 1 to 254 DHCP IP Address Lease Time 0 Disable Server Port Number Enter value from 1 to 254 Character Spreading Speed Up 0 Disable Unit Print on Receipt 0 Pcs Code Page 0 DOS SM-500 2 Receipt Printer 0 Disable Praxis Function 0 Disable
nd

SM-100 9

1 1 2 3 4 5 6

No Change 8 Power Off 8 10 Min 2 Min 9 1 Min 2 Min 5 Min


For U1 only.

294 295 296 297 298 299

8 1 1 1 1 1 2 No 8 12 Lines 8 Maximum 255 records Yes Yes 8 80 Preset Keys


# 32/56 Preset Keys. Identical to SPEC672. For SF only.

300

8 1 Yes
96 Preset Keyboard. Identical to SPEC688.

301 302 303 304 305

9 1 No

Enable

8 1 Enable
(S3, S4, M3 & M4) For U1 only.

306 307 308 309

1 1 1

Items 8 ANSI Enable 8


For IR only.

Enable

For DEC countries only.

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

15 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 310 Multi Barcode Type 0 EAN128 1 RSS

SPECIFICATION DESCRIPTION 9 2 CODE128

SM-100

For AI 01 only.

311 312 313 314

Operator Logging Function 0 Disable Price Change Password 0 Disable Price Change Log File 0 Disable Training Mode 0 Disable 1 Enable Print PLU Traceability in Receipt 0 Yes

1 1 1 2

Enable 9 Enable Enable Enable (Clerk Report)


For CA only.

9
For CA only.

8
For DEC only.

315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330

8 1 No 9 No 9 1 Yes
Not in used.

Include Prepack Total in Manual Total Report 0 Yes 1 Wireless Communication 0 No Wireless FTP Port Number Enter value range from 1 to 9999 Delete Traceability Record 0 Yes PLU Link to Text Field 0 Disable Julian Date for Packed and Sell Date 0 No Price Printing Size (Large Font) 0 No Auto PLU Broadcasting 0 Disable 1 1 1 1 1

9 No Enable 8 Yes Yes Enable 8 Enable No Change 9 1 1 1 1 1 Disable 8 Enable 8 Enable Inhibit 8 Yes
For Tu only. For U1 only.

Decimal Point For Unit Price And Total Price 0 Disable 1 Peel Sensor Value 0 Re-adjust ON/Off Key 0 Enable SM300 Print Control 0 TU 9 Digit Total Price 0 Disable PLU Tare Call up 0 Allow Individual Scale Store Total Report 0 No 1

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

16 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 331 332 333 334 335 336 337 Default ITF for Barcode 0 Disable

SPECIFICATION DESCRIPTION 9 1 1 Enable 9 Enable

SM-100

ITEM Text (5-16) Print on Total Label 0 Disable Image at Top Receipt Enter range from 0 to 99 Image at Bottom Receipt Enter range from 0 to 99 Traceability Eat By Date 0 Disable Traceability Max Weight 0 Disable Traceability Default Label Format 0 Not Used 1 F1 2 F2 3 F3 4 F4 Traceability Barcode 0 EAN13 Flag Data (EAN13) Enter range from 0 to 99 Enforce Scan 0 No TVP2000 (SM300) 0 Not Send T10 LCD 1 Line Scroll 0 Disable Clear Key in Prepack 0 Enable Print Pack Date 0 Yes Update Spec For Server/Client System 0 Enable

1 1 5 6 7 8

Enable Enable F5 F6 F7 F8

338 339 340 341 342 343 344 345 346

EAN128

1 1 1 1 1 1

Yes Send T10 Label Format Enable Disable No Disable Only In Prepack Mode Both

Update Label Turn-over In Receipt Buffer 0 No 2 1 Only In Registration Mode 3 Internet Broadcast 0 No Taiwan POP Label 0 Disable Direct Access To Clerk Mode 0 Disable

347 348 349

1 1 1

Yes Enable Enable

For TW only

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

20 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 350 351

SPECIFICATION DESCRIPTION Additional Rounding In Receipt 0 Print Gratuitous ARP 0 Disable

SM-100

1 1

No Print Enable

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

21 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 400 Auto Power-Off Function 0 Inhibit 1 3 Minutes 2 10 Minutes

SPECIFICATION DESCRIPTION 9 3 4 5 1 30 Minutes 1 Hour 3 Hours 9 Off 9

SM-100

401 402 403 404

RTS/CTS Handshaking of RS-232C 0 On

Reset Receipt consecutive Number after Reset Report 0 No 1 Yes Vender Number Display in Registration Mode 0 Allow 1 Inhibit Number of Vender Keys 0 4 Vender Keys 1 5 Vender Keys 2 3 6 Vender Keys 7 Vender Keys

9 9

405 406 407 408 409 410 411 412 413 414

Priority of Shop Name and Special Message on Receipt 0 Shop Name Priority 1 Special Message Priority Centering of shop name on Receipt 0 Allow 1 Inhibit

Centering of special Message on Receipt 0 Allow 1

9 Inhibit 9 9

One or Two Touch for Receipt Printing in AMT/TEND 0 One Touch 1 Two Touch PLU Number Printing on Receipt 0 Inhibit Sale Item Entry Method 0 Total 1 1 Allow

9 Item 9 Inhibit 9 1 1 No Print 9 Packed Date 9 F1F2 CCCCC XCD TTTT CD F1F2 CCCC XCD TTTTT CD F1F2 CCCCC PCD TTTT CD F1F2 CCCCC 0 TTTT CD
#1: F1F2 - 20~29 #2: CC ~ CCCCCC Item code. #3: TTTT ~ TTTTTTTT Total Price

Default Vender Transaction by Print Key 0 Allow 1 Print Checking Line 0 Print Source of Used by Date 0 Current Date

In-Store Barcode for Barcode Scanner Enter 0 F1F2 CCCCCC TTTT CD 5 1 F1F2 CCCCC TTTTT CD 6 2 F1F2 CCCC TTTTTT CD 7 3 F1F2 CCC TTTTTTT CD 8 4 F1F2 CC TTTTTTTT CD Non-PLU Item Enter by Barcode Scanner 0 Allow 1 Barcode Scanner 0 Allow 1

415 416 417

9 Inhibit 9 Inhibit 9 Inhibit

Centering of Commodity Name on Label 0 Allow 1

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

22 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 418 419 420 421

SPECIFICATION DESCRIPTION Weight Data Synchronization Function 0 Allow Open Cash Drawer when Issue Label 0 Allow Print Grand Total on Sales Report 0 Allow Constitution of Report 0 Receipt Data 1 Label Data 9 1 1 1 2 Inhibit 9 Inhibit 9 Inhibit 9 Receipt Data & Label Data 9

SM-100

422

Currency Symbol for Total Amount on Receipt 0 No Print 2 Suffixation 1 Prefixion Print Total Number of Pieces on Receipt 0 Allow 1 Total Barcode on Receipt for Total Price in 2 0 Allow 1 Second Currency as Reference Price 0 No 1 For Receipt Print Tare Weight when Unit Price is 0 0 Allow 2 3 1
nd

423 424 425

9 Inhibit Currency Inhibit For Label For Receipt and Label 9 Inhibit 9 9
For FR only.

426 427 428

Eliminate Cash Line on Receipt when No change Operation 0 Allow 1 Inhibit PRINT Tax List on Receipt 0 Allow Non-Weigh PLU Unit Price Display 0 Total Price Column 1 Inhibit

9
Effective when SPEC603 =1

429 430 431 432

9 1 Unit Price Column 9

Items on PLU / Main Group / Dept / Tax Report 0 Registered Items 1 All Items Eliminate Vender Data on Sales Report 0 Allow 1 Inhibit

Font Size for Commodity Name on Receipt 0 Standard Font Size 2 1 Larger Font Size

9 Largest Font Size 9

433 434

Condition of Additional Price Rounding for Total Price 0 Cash Payment Only 1 Always Item Barcode Type 0 EAN Type 1 ITF Type Total Barcode Type 0 EAN Type 2 User Programmable

435 436 437

9 1 ITF Type 9 9 1 Inhibit

In-Store Barcode Type for Barcode Scanner Enter 0 EAN Type 1 ITF Type Print Rounding on Receipt 0 Allow

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

23 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 438 439

SPECIFICATION DESCRIPTION Print Sub-Total on Receipt 0 Allow Pulse width for Opening Cash Drawer 0 20ms (Default Value) 1 50ms 2 100ms R Mode Password Function 0 Inhibit 1 Password R Key 9 1 3 4 5 2 Inhibit 9 200ms 300ms 400ms 9 Power On & Password R Key 9

SM-100

440

441 442 443

Set / Reset Auto PLU Call Function Key Enable 0 Allow 1 Inhibit Change Main Group Code for Auto Plu Call Function Key Enable 0 Allow 1 Inhibit Prefix Fixed Code to PLU Code for Auto PLU Calling 0 No 2 2 Digits 1 1 Digit 3 3 Digits Decimal Point Position for Second Currency 0 None 2 1 0.0 3 0.00 0.000

9
Effective when Spec39 = 1, Spec40 = 0

444

445 446 447 448 449 450 451

Unit Price Change for PLU after Label Printing 0 Inhibit 1 Allow Print Tare Weight on Receipt 0 Allow 1 Inhibit

Place Change for PLU after Label Printing 0 Inhibit 1

9 Allow
For KE only.

Sell Date Change for PLU after Label Printing 0 Inhibit 1 Allow Trace Auto Clear 0 Inhibit Trace per PLU 0 Inhibit Trace Auto Update 0 Inhibit Trace Confirm 0 Inhibit Trace C/D Check 0 Inhibit 1 1 1 Allow Allow Allow

9
For KE only.

For KE only.

For KE only.

For KE only. Effective when Spec450 = 1.

452 453

1 1

Allow Allow

For KE only.

For KE only.

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

24 of 32

Specification List SPEC NO. 454 455

SM-100 V2.00

26 December, 2006

SPECIFICATION DESCRIPTION Forced Tare when Tare Value in PLU is 9999 0 Inhibit 1 Printing of Servings Fact 0 SS Top & SC Bottom 1 SS Bottom & SC Top Special FOR operation 0 Inhibit CN Weight Trace function 0 Inhibit CN Weight Quota function 0 Inhibit Symbol Format for Date Print 0 Dash CN Weight Trace Password 0 Inhibit 2 3 1 1 1 1 1 9 Allow SS Print Only SC Print only Allow Allow Allow Period 9 Allow

SM-100
For CA only.

9
For CA only.

456 457 458 459 460

9
For U1 only.

9
For CN only.

9
For CN only.

For CN only.

461 462

Unit and Currency Symbol for each line in Receipt 0 Inhibit 1 Allow 1000 Separator for total line print on receipt 0 Inhibit 1 Print SHAMSI date 0 Inhibit 1 Allow Allow

9
For U1 only.

9
For IN only.

463

9
For IN only.

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

25 of 32

Specification List

SM-100 V2.00

26 December, 2006

[REZERO] + [1][4][2] WEIGHT AND MEASUREMENT SPECIFICATION


(Span Switch must be ENABLE when accessing this mode.) SPEC NO. 600 SPECIFICATION DESCRIPTION Price Base for Price Calculation for Weighed Items 0 100 g Base 2 1 lb Base 1 1 kg Base Auto Zero Function 0 Enable Display Type 0 Single Display Tax 0 No Tax Minus Weight Masking 0 Minus Gross > 9e Manual Scale Start 0 Auto Start Zero Lamp Lighting Position 0 Gross Zero +/- d Decimal Point Position for Weight 0 None 1 0.0 1 1 1 1 1 1 2 3 Disable 8 Three Display 9 Tax 9 Minus Gross Weight Mask 8 Manual Start 8 Net Zero +/- d 9 0.00 0.000 9 9 SM-100

601 602 603 604 605 606 607

608

Zero Point Setting Range when A/C Display Switch On 0 +/- 10% of Capacity 2 +/- 3% of Capacity 1 +/- 5% of Capacity 3 +/- 2% of Capacity Decimal Point for Unit Price and Total Price 0 None 2 1 0.0 3 Unit Price Decimal Right Shift 0 Inhibit Unit Price Decimal Left Shift 0 Inhibit Switching of Price Base 0 Inhibit 1 100 g / 1 kg 1 1 2 0.00 0.000

609

610 611 612

8 Allow 8 Allow 9 500 g / 1 kg 9

613

Exit from Accumulation Mode after within Specified Interval 0 Inhibit 2 5 Sec 1 15 Sec 3 10 Sec Zero Setting Range when Weight Reset Switch is On or Zero Tracking 0 +/- 10% of Capacity 2 +/- 2% of Capacity
(Power on Start Point +/- 6000 IR) (Power on Start Point +/- 1200 IR)

614

1 615

+/- 5% of Capacity
(Power on Start Point +/- 3000 IR)

+/- 0.6% of Capacity


(Power on Start Point +/- 360 IR)

Minimum Display 0 1 1 2

9 2 3 5 10

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

26 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 616 617 618 619 Selection of Resolution 0 1/3000 1 1/6000 New A/D 0 No

SPECIFICATION DESCRIPTION 9 2 1 1 1/7500 8 Yes 9 Multi-Interval 8 No Display

SM-100

Weight Single Interval or Multi-Interval 0 Single Interval

PLU Weight Item Commodity Name Display 0 Full Display 2 1 Half Display Tare Accumulation 0 Allow Tare Subtraction 0 Allow Manual Clear of Tare 0 Allow Weight Reset Operation during Tare 0 Allow Zero Tracking during Tare 0 Allow Accumulation when Tare 0 Allow Digit Tare 0 Allow Decimal Point Figure 0 Period 1

For EB and EP type.

620

9 Inhibit
Effective when SPEC632 = 0.

621

9 1 Inhibit
Effective when SPEC632 = 0.

622 623 624 625 626 627 628

9 1 1 1 1 1 1 Inhibit 9 Inhibit 9 Inhibit 9 Inhibit 9 Inhibit 9 Comma 9

Price Rounding Method for Decimal Digits on Weighed Item 0 Rounding 2 Cut Up 1 Truncating Additional Price Rounding Method for Item Price st 0 No Addition Rounding 4 Rounding for 1 Digit st 1 Rounding (25 step) 5 Truncate 1 Digit st 2 Special Rounding (5 step) 6 Cut Up 1 Digit 3 5 Floor Rounding (0~4: 0, 5~9: 5) Selection of Auto Clear of Unit Price 0 Inhibit Selection of Maximum Capacity 0 Capacity +1d Selection of Tare Value Exchange 0 Allow Auto Clear of Tare 0 Inhibit 1 1 1 Allow

629

630 631 632

8 Capacity +9d 8 Inhibit


Related to SPEC620 and 621.

633

9 1 Allow

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

27 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 634

SPECIFICATION DESCRIPTION Auto Tare Clear when Rezero 0 Inhibit 9 1 Allow

SM-100

Effective when SPEC623 = 0.

635 636 637

Trigger Point of Tare / Unit Price Auto Clear 0 Over Net 5d and Gross 21d and 1 Weight Stability Auto Zero Reset 0 Inhibit 1 Negative Weight Tare Clear 0 Allow Tare Range 0 < 50% of Capacity 1 < 5% of Capacity 1

9 >= Net 1d and Price > 0 and Weight Stability Allow 8 Inhibit
Effective when SPEC622 = 0. Effective when SPEC633 = 1.

638

8 2 3 Maximum 200 g Not Used 9

639 640 641

Exit From Accumulation Mode when Weight Change 0 Inhibit 1 Allow Price Accumulation with Weight Change More than +/- 10d 0 Inhibit 1 Allow Accumulation Available Only after Scale Shows Weight is Equal Zero 0 Inhibit 1 Allow Tare Display for One Touch Tare 0 Allow Weight Range for Non-weigh Item 0 Only Net 0d Weight Stability Condition 0 Loose 1 Normal Weight Range for R Mode Printing 0 Over Net 5d and Over Gross 21d and Weight Stability 1 Over Net 1d and Weight Stability Weight Range for Prepack 0 Over Net 5d and Over Gross 21d and Weight Stability 1 Over Net 1d and Weight Stability PLU Tare 0 Allow Item Print when Tare 0 Allow Tax Rounding Method 0 Rounding

9
Effective when SPEC640 = 0.

642 643 644

8 1 1 2 3 2 3 2 3 1 1 1 Inhibit 9 Always 9 Tight Stringent 9 Over Net 19d and Weight Stability Over Net 20d and Weight Stability 9 Over Net 19d and Weight Stability Over Net 20d and Weight Stability 9 Inhibit 9 Inhibit 8 Truncation 9 Yes 8 1 Numeric Key Precede Function Key

645

646

647 648 649 650 651

Checking Span Switch for Internal Count 0 No 1 Certain Function Key Order 0 Function Key Precede Numeric Key

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

28 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 652 653 654 655

SPECIFICATION DESCRIPTION Angle Rotation for Certain Items Printing 0 Anti-clockwise 1 Total Price Discount 0 Allow Packed Date Function in Manual Mode 0 Inhibit Prepack Mode 0 Allow Scale Type 0 Pole 1 Bench 2 Elevated 3 Hanging 4 Self-service Password Setting 0 Allow Extra Label for Prepack Printing 0 Inhibit Item Price Printing 0 Item Price before Tax Barcode Check Line 0 Print 1 1 1 9 Clockwise 9 Inhibit 9 Allow 9 Inhibit

SM-100

Always set to 1 for SM200.

656

9 5 6 7 8 Cassette-B Cassette-P B-CS P-CS


Always set to 0 for SM200.

657 658 659 660 661

9 1 1 1 1 Inhibit Allow 8 Item Price after Tax 9 No Print 9


By-pass Span Switch.

Additional Price Rounding Method for Total Price st 0 No Addition Rounding 4 Rounding for 1 Digit st 1 Rounding (25 step) 5 Truncate 1 Digit st 2 Special Rounding (5 step) 6 Cut Up 1 Digit 3 5 Floor Rounding (0~4: 0, 5~9: 5) Unit Price Recalculation 0 Inhibit Nordic Country 0 Inhibit Self-service Type 0 Inhibit 1 1 1 Allow

662 663 664

8 8 Allow 9 Allow
Related SPECs are 126, 136, 672.

665 666 667

Swap of Unit Price and Total Price Display in R Mode 0 Inhibit 1 Allow Multiplication Operation in Prepack Mode 0 Inhibit 1 Dot Matrix Display Scanning Rate 0 Normal 1 Slow R Mode Display Configuration 0 Standard 1 Without Tare Weight 2 3 2 3 Allow

8 High Very High 8 Not Used Not Used

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

29 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 668

SPECIFICATION DESCRIPTION Commodity Name Display Interval 0 0.5 Sec 1 1.0 Sec 16 x 16 Commodity Name Display 0 1.0 Sec 1 1.5 Sec 9 2 3 2 3 1 1 1 2 1.5 Sec # 2.0 Sec # 2.0 Sec 2.5 Sec Yes 8 Half Length Version 0.16 and Above 8 80 Preset Keys

SM-100

For EB and EP type. # Effective when SPEC619 = 0.

8
For CN, HK, MS and TW.

669 670 671 672

Mask Weight Display 0 No Scroll Message Display 0 Full Length Display CPU Selection 0 Below Version 0.16 Keyboard Selection 0 Normal Keyboard # 1 100 Preset Keys Hanging Scale 0 No Masking Last Digit Over 15 lb 0 No Auto Zero Adjustment Range 0 +/- 5d

For EB and EP type.

# 32/56 Preset Keys.

673 674 675

8 1 1 1 Yes 8 Yes 8 2% of Capacity


Effective when SPEC636 = 1.

676

Right Side Barcode Data Shifting for Item and Total Barcode 0 No 3 Left Shift Twice 1 Right Shift Once 4 Left Shift 3 Times 2 Right Shift Twice 5 Left Shift Once Manual Weight Function Key 0 Disable 1 Enable

9
(left shift valid for quantity only)

677 678

9 8 Allow
For SS type. Effective when SPEC640 and 641 = 1.

Printing of Item Label after Weight Change 0 Inhibit 1

679

Catty (Kati) and Tael 0 Disable

8 1 Enable
Available in special version only.

680

Tare Clear when Exit From Z mode, Password Mode, Changing of Customer, and Weight and Measure Specification 0 No 1 Yes Euro Second Price Rounding Method 0 Rounding 1 Truncating 2 Cut Up

681

682

Additional Euro Second Price Rounding Method st 0 No Addition Rounding 4 Rounding for 1 Digit st 1 Rounding (25 step) 5 Truncate 1 Digit st 2 Special Rounding (5 step) 6 Cut Up 1 Digit 3 5 Floor Rounding (0~4: 0, 5~9: 5) Foreign Code for Standard Countries 0 Inhibit 1 GB Code 2 Korean Code

683

8
Not effective for AA, CN, HK, KE, MS and TW.

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

30 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 684

SPECIFICATION DESCRIPTION Calibration at 1/5 of the Capacity 0 Disable 8 1 Enable

SM-100

Not effective when SPEC615 = 0.

685 686 687 688 689

Auto Selection Between Two Label Format 0 Inhibit 1 Rounding for Weight 0 No Proportional Tare 0 No SM-500 Self-service 0 No Consecutive Display 0 1 Sec Stop 1 2 Sec Stop Test Program 0 Disable One Touch Tare 0 Enable RESERVED Flexi Self-Service Key Grouping 0 No Weight Hold Function 0 Disable Clerk Password Setting 0 Disable Quantity Symbol Re-calculation 0 No RESERVED DEC PLU Tare 0 No Right side Data of Barcode Shift 0 Normal 1 Quantity 1 2 3 1 1 1 1 1 1 1 2 3 1 1

8 Allow 9 Yes 9 Yes 8 Yes 8 4 Sec Stop 6 Sec Stop 8 Enable 8 Disable 8 9 Yes 8 Enable 9 Enable Yes 8 8 Yes 9 Weight Price
For CA only.

690 691

692 693 694 695 696

697 698 699

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

31 of 32

Specification List

SM-100 V2.00

26 December, 2006

SPEC NO. 700 701 702 703

SPECIFICATION DESCRIPTION Version Display When Power On 0 Allow Re-Zero Function 0 Allow Total Price Display 0 Allow 9 1 1 1 Inhibit 9 Inhibit 9 Inhibit 9

SM-100

Tax Rounding Method for Tax Value Excluded in Price 0 Rounding 2 Cut Up 1 Truncation Tax Rounding Method for Tax Value Included in Price 0 Rounding 2 Cut Up 1 Truncation Commodity Name Display When Call PLU in Label Mode 0 Allow 1 Inhibit Commodity Name Display When Call PLU in Receipt Mode 0 Allow 1 Inhibit Price Fix 0 Inhibit 1 Allow Tare Fix 0 Inhibit 1 Allow 2 Via FIX Key

704

705 706 707

708

9 2 Via FIX Key 9

709 710 711

Printing of Item Label Condition in Prepack Mode 0 Weight Change (More than +/-10e) 1 Remove Weight Net / Gross Multi-interval 0 Gross Multi-interval Priority of Tare Operation 0 One Touch Tare Priority Receipt mode 0 Allow 1 1 Net Multi-interval Digit Tare Priority

712

9 1 Inhibit

nd

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.

32 of 32

SM-100 Flexible Barcode Setting Guide


Operation Press [mode] third S1 times Enter Press numeric 4 and 6 S46 -- --> FLEXI BARCODE programme. Press [*] Enter numeric 1 S46.0 S46.0 F BAR F BAR 0 1 NO SET NO SET Program Flexible Barcode. Program Flexible Barcode 1. Program Flag Code.0 for F21 Press [*] S46.1 F BAR 0 FLAG for F1F22 for non. Flexible Barcode -- --> PLU FILE Enter programmer. Display tare weight Unit price/kg price Remark

Press [*]

S46.2

F BAR

ITEM CODE

Enter item code length. Enter data format for DATA1.( 0 for weight,1 for quantity,2 for unit

Press [*]

S46.3

F BAR

DATA1

price.3 for weight/quantity,4 for total price,5 for original price,6 for user programmable.)

Press [*]

S46.4

F BAR

DIGIT

Enter DATA1 length. Shift for DATA1.( 0 for no right shift,1 for right shift, 2 for right

Press [*]

S46.5

F BAR

SHIFT

shift x2, 3 for left shift, 4 for left shift x2, 5 for left shift x3. Enter data format for DATA2.( 0 for weight,1 for quantity,2 for unit

Press [*]

S46.6

F BAR

DATA2

price.3 for weight/quantity,4 for total price,5 for original price,6 for user programmable.)

Operation

Display tare S46.7 weight F BAR Unit price/kg 0 price DIGIT

Remark

Press [*]

Enter DATA2 length.

Shift for DATA2.( 0 for no right shift,1 for right shift, 2 for right Press [*] S46.8 F BAR 0 SHIFT shift x2, 3 for left shift, 4 for left shift x2, 5 for left shift x3. Press [] to select the Press [*] S46.9 F BAR NO MIDDLE CD middle check digit. Press [] to select the last Press [*] S46.1 F BAR NO LAST CD check digit. Press [] to swith ITF and EAN barcode. Press [#] S46 -- --> FLEXI BARCODE Save the flexible barcode 1.

Press [*]

S46.1

F BAR

ITF BARCODE

Note: See the Flexible Barcode Usage Note at 3.6.1 PLU programming in SM-100 Operation manual.

SM-100 Traceability Setting Guide


Prepare
Set SPEC258 to 1

Traceability Programming
Operation Display tare S1 weight Unit price/kg price PLU FILE Remark

[Mode] [Mode] [Mode]

Enter S mode

[3] [4]

S34

COUNTRY FILE

Enter country file programming

[*] [1]

S34.0

NO SET

Program country No. 1

[*][C][H][I][N][A]

S34.1

COUN

CHINA

Name 5

Program country name CHINA

[#]

S34

COUNTRY FILE

Save Country No. 1

[3] [5]

S35

CUTTING HALL

Enter cutting hall programming

[*] [1]

S35.0

HALL

NO SET

Program cutting hall No. 1

[*][1]

S35.1

HALL

COUNTRY

Program cutting hall country No. 1

[*][C][U][T]

S35.2

HALL

CUT

Name 3

Program cutting hall name CUT

[#]

S35

CUTTING HALL

Save cutting hall No. 1

Operation

Display tare S36 weight Unit price/kg SLAUGHTER price Enter HOUSE

Remark slaughter house

[3][6]

programming

[*][1]

S36.0

HOUSE

NO SET

Program slaughter house No. 1

Program slaughter house country [*][1] S36.1 HOUSE 1 COUNTRY No.1 Program slaughter house name [*][S][L][A][U][G] S36.2 HOUSE SLAUG NAME 5 SLAUG

[#]

S36

SLAUGHTER

HOUSE

Save slaughter house No. 1

[4][7]

S47

KIND FLIE

Enter kind file programming

[*][1]

S47.0

KIND

NO SET

Program kind file No. 1

[*][M][E][A][T]

S47.1

KIND

MEAT

NAME 4

Program kind name MEAT

[#]

S47

KIND FILE

Save kind file No. 1

[4][8]

S48

CATEGORY FILE

Enter category file programming

[*][1]

S48.0

CATEG

NO SET

Program category No. 1

[*][B][E][E][F]

S48.1

CATEG

BEEF

NAME 4

Program category name BEEF

[#]

S48

CATEGORY FILE

Save category file No. 1

Operation

Display tare S49 weight Unit price/kg price BREED FILE

Remark

[4][9]

Enter breed file programming

[*][1]

S49.0

BREED

NO SET

Program breed file No. 1

[*][B][U][L][L]

S49.1

BREED

BULL

NAME 4

Program breed name BULL

[#]

S49

BREED FILE

Save breed file No. 1

[3][7]

S37

TRACEABILITY

Enter traceability programming

[*][1]

S37.0

TRACE

NO SET

Program traceability No. 1

[*][1]

S37.1

TRACE

BORN

Choose born country No. 1

[*][1]

S37.2

TRACE

FATTEN

Choose fatten country No. 1

[*][1]

S 37.3

TRACE

S HOUSE

Choose slaughter house No. 1

Choose link country No. 1 for [*][1] S37.4 S CNT 1 LNK 1 slaughter house

[*][1]

S37.5

TRACE

C HALL

Choose cutting house No. 1

Choose link country No. 1 for [*][1] S37.6 C CNT 1 LNK 1 cutting hall

[*][1]

S37.7

TRACE

ORIGIN

Choose original country No. 1

Operation

Display tare S37.8 weight R-CD Unit price/kg RCD price NAME 3

Remark

[*][R][C][D]

Program R-CD content RCD

[*][G][T][I][N]

S37.9

GTIN

GTIN

NAME 4

Program GTIN content GTIN

[*][L][O][T]

S37.10

LOT

LOT

NAME 3

Program LOT content LOT

[*][1]

S37.11

TRACE

KIND

Choose kind No. 1

[*][1]

S37.12

TRACE

CATEG

Choose category No. 1

[*][1]

S37.13

TRACE

BREED

Choose breed No. 1

[*][C][O][N][T]

S37.14

CONT

CONT

NAME 4

Program cont content CONT

[*][0][6][0][3][1][0]

S37.15

TRACE

060310

EAT D

Program eat by date 06/03/10

[*][5][0][0][0]

S37.16

TRACE

5.000

WEGHT

Program maximum weight 5kg

[*][S][C][D]

S37.17

S CD

SCD

NAME 3

Program S CD content SCD

[*][S][N][M]

S37.18

S NM

SNM

NAME 3

Program S NM content SNM

[*][S][A][D][1]

S37.19

S AD1

SAD1

NAME 4

Program S AD1 content SAD1

[*][S][A][D][2]

S37.20

S AD2

SAD2

NAME 4

Program S AD2 content SAD2

[#]

S37

TRACEABILITY

Save traceability No. 1

Free Format Programming


Enter S12 FREE FORMAT, press [*] Edit the correlative items for traceability in free format

PLU ITEM Programming


Enter S19 PLU ITEM, press [*] Set Item TRACE to PROGRAM and press [#] to save

PLU Programming
When you edit PLU, set S1.64 PLU to TRACE ALLOW and press [*] Input traceability number and press [#] to save In the end, when you call the PLU and print label, youll see the traceability information on the label

SM-100 Nutrition Fact Setting Guide


Concept
Nutrition uses fix template to print. Totally It has 12 fix templates(No. 70 ~ No. 81).

Setting Method
1. 2. 3. 4. 5. 6. Enter S mode Enter S19 --- PLU ITEM and set IMAGE and NUTRI to PROGRAM Enter S12 --- FREE FORMAT Enter S12.5 IMG 1 47 F ITEM to S12.5 IMG 10 56 F ITEM to set the print area of Nutrition. (In each label format, totally you can print 10 images) Enter S1 --- PLU FILE to create PLU. Enter S1.50 PLU 0 IMAGE 1 to choose the template number for IMAGE 1 (From No. 70~ No. 81). Enter S1.59 PLU 0 IMAGE 10 to choose the template number for IMAGE 10 (From No. 70~ NO. 81). Set S1.81 PLU PRINT NUTRI to set nutrition print status to Print. Enter from S1.82 to S1.10 to input nutrition contents. For extra details on the Nutrition Fact, Enter S11: TXT form to edit by hands. Enter S12 --- FREE FORMAT to set up the TXT position. Press [PLU] key to save.

7. 8. 9. 10. 11. 12.

PCFL-1 Operation Guide


Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail: steservice@digi-scale.com

Note: this guide is available just for SM series expect the SM-100. The link of the hardware Link the PC with scale via RS232C.

Operation 1. The Spec setting in the scale 3 for SPEC51 1 for SPEC52 0 for SPEC53 0 for SPEC54 2 for SPEC60 (The SIO baud rate is 9600. ) (The SIO data length is 8.) (No SIO parity digit.) (1 bit stop bit.) (SIO work via PCFL-1)

2. The setting in the software 1) open the software

PCFL-1 Operation Guide


Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail: steservice@digi-scale.com

2) the com port setting

Please note: a) The com port should be the same as the one used in your computer. b) The com port setting must be same as setting in the scale. 3) the folder for save

PCFL-1 Operation Guide


Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail: steservice@digi-scale.com

Note: You could set the default folder for save the data received from the scale. 3. Operation 1) receive the data from the scale

PCFL-1 Operation Guide


Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail: steservice@digi-scale.com

Note: You could press the key to receive the data from scale. 2) send the data to scale

Note: You could press the key to send the data to scale. 2) the operation in the scale Display Operation Weight Unit price
[M][0][M][M] [zero]+[0][1][0] Preset key [8] Preset key [8] Preset key [8] DAILY BAC BAC BAC BAC 0 PLU FOR OTH ALL

Remark Price
CLR FILE FILE FILE FILE

Z
X X X X X Enter the [Z] mode

Press preset key [7]or [8] to select the transmit item: PLU, Format, Others or All.

PCFL-1 Operation Guide


Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail: steservice@digi-scale.com

[*] Preset key [8] Preset key [8] [*] [Tare]

BAC BAC BAC T-OUT DAILY

SA TO RD FR COMP OPN 0

FL-1 FL-1 FL-1 GOOD CLR

X X X X X

Press preset key [7]or [8] to select the transmit method: save data to FL-1,read data from FL-1,verify data with FL-1. Transmit successfully. Back to Z mode.

Jasonzhou, Shanghai Teraoka Electronic Co.,Ltd Technical Service Dept. Dec. 7 ,2005
th

SM100

ERROR MESSAGE

9. SM100 ERROR MESSAGE


ERROR MESSAGE The machine beeps and following error messages appear on display, if incorrect operation is performed.
No. 1 2 3 4 6 7 9 12 14 16 18 19 20 24 26 29 39 44 48 49 54 57 59 61 71 74 95 96 97 98 99 Error Message PAPER END FEED PAPER FIRST PEEL LABEL CHANGE PAPER NON PRINT UNIT PRICE OVERFLOW NON LABEL MEMO NOT INITIALIZED HEAD IS NOT CLOSED FILE MEMORY FULL PLEASE REMOVE WEIGHT PLU NOT EXIST TOTAL PRICE IS 0 WEIGHT OF TOTAL PRICE OVERFLOW PLEASE SET TARE VALUE PLEASE PRESS PLU KEY KEY ALREADY ASSIGNED PLU DATA INVALID QTY OF BELOW MIN WEIGHT PRICE ACC OF PLEASE SEE LABEL QTY GRAND TOTAL OF PRINT INHIBITED SELF SERVICE MODE CAL00 ERROR CALSP ERROR FORMAT ERROR NO DATA IN REPORT EXCEED WEIGHT QUOTA label roll Label miss feed, press FEED key to align label. Peel sensor activated, remove label away from sensor. Change paper mode between label and receipt. No manual printing. Please check unit price. No free format is programs. Set a free format or use standard format. Memory problem. Please clear the memory. Thermal head no closed. Please close thermal head. Not enough memory. Expand memory or delete unnecessary data. Fixed price item, please remove weigh. No such PLU data or number exists. No total price for item. Unit price, weight or quantity is 0. Weight over maximum capacity when print. Total price over the limit to display or print. When force tare is enable, a tare weight must be entered. Press PLU(#) key. To save data in some procedure. Preset key already been assigned with function or PLU. U1 only. Quantity setting incorrect when using FOR. Quantity data over the limit. Weight is below min weight set when printing. Accumulated quantity over the limit. Set print label quantity when the function is use. Grand total price over the limit. Cannot print weigh item at Prepack mode. Can only use Self-service procedure only. Zero point calibration error. Full scale point Calibration error. No free format is program. There is no data in report when printing report. CN only. Please reset weight quota. Causes Label sensor sense no label. No more labels. Replace

SM100

ERROR MESSAGE

FATAL MESSAGE
No. F002 F003 F004 F005 F006 F007 Fatal Error Message External flash memory erase error External flash memory program error External flash memory program error Internal RAM read/write error External RAM read/write error External ethernet IC read/write error

Anda mungkin juga menyukai