PowerAsiaTechnology
30-60% saving
12-20% saving
8-12% saving
1-5% saving
Indoor MCU
L (220V) N (220V)
TSR Comp
DDC
Signal wire
Pressure
Inverter
Temperature
3 AC Main Source
3 , f, V
3 Meter
Fuzzy PID
DIFF
Temperature Parameter
Note: 3 meter can display wattage consumed to reflect motors energy consumption under different temperature parameters
Energy saving with variable speed motor control (30%-60% saving) Cooling tower motor, pumps motor, AHU, blower, compressor motor and more.
Inverter
3 AC Main Source
3 , f, V, I
3 Meter
RS-485
PID Parameter
PC
RJ-45 RS-485 RS-485
Intelligent Controller
Temperature Parameter
RS-485/RJ-45 Converter
RS-485 Hub
Note: Except wattage as in option 1, f, V, I and temperature can also be displayed on PC Two programs of control software are required to code and port on PC
Heating/Cooling
Alarm Output
RS232 programming
105mm
Ambient Temperature Low Temperature Motor Temperature
135mm
Humidity/Pressure Analog Input1 Humidity/Pressure Analog Input2 To Inverter Analog Output1&2 24Vdc Supply
DIFF
S
CT2
T
CT3
Motor on-off remote control
PAT-VC
R S T R
b
S
MC BYPASS
T
a AC input for MC control **
* The voltage of the AC input for the indicator depends on the voltage of the indicator.
MOTOR
** The voltage of the AC input for the MC control depends on the voltage specification of the MC.
Application: Escalator
Speed: Constant Control: Motion Sensor Inveter Inverter: Speed reduces when nobody on escalator
Application: Escalator
Speed: Constant Control: Monitor current VC board: Speed remain when nobody on escalator. Voltage & Current reduces. 1ms response time when load return.
Application
Motor Size Average Savings Savings (down) Power Tariff Annual Saving (12hr x 365)
Escalator
40Hp (30kw) 35.75% 6.08kw to 4.00kw $0.30/kwh $2,628
SES-VT series
Feature:
Power Saving Efficiency: 10% Plug and Save, Easy to Install Multiple Power Protection functions Enhance anti-harmonic interference protection
Spec: 110-220Vac 1 , 10A / 15A Max Application: High Electrical consuming home appliances, e.g. refrigerator, washing machine, water pump, dehumdifier.
20
VS/VK mixed load energy saving Saving 18-25% Single or Three phase
Power Line
Utility Meter
NFB
Power Line- L1
NFB
NFB
NFB
SES-VTL series
Super Light Saving Adapter Feature:
Power Saving Efficiency: 10% Plug and Save, Easy to Install
Spec: 110-220Vac 1 , 10A / 15A Max Application: Home, Office, Building, Business Centre, Factory
24
Summary
DIFF
VR
VC
VS/VK
VT/VTL