Anda di halaman 1dari 26

THREE-PHASE MOTOR CONTROLLERS

PowerAsiaTechnology

Three-phase motor controllers feature:


soft start and soft stop energy savings MOTOR PROTECTION phase loss protection low and high voltage protection over current protection JOGGING remote motor start-stop control automatic external bypass ENERGY SAVINGS jogging
SOFT START AND SOFT STOP AUTOMATIC EXTERNAL BYPASS

Different level of Energy Saving devices


Close loop variable motor speed control Voltage Regulating for fixed motor speed

Inverter + controller + feedback signal


Slow Reaction time, result motor damage Fast Reaction time of 1 10ms

30-60% saving

Fixed Ratio Variable Ratio

12-20% saving

Voltage / Current Regulating for inductive load Capacitor Bank

Lowering the V and I respectively

8-12% saving

Power Factor correction

1-5% saving

Energy Saving for motors


Control system with energy saving module (frequency-varied)
RST
Outdoor terminal block Outdoor unit

Indoor MCU
L (220V) N (220V)

TSR Comp

DDC
Signal wire
Pressure

Inverter
Temperature

(External) energy saving control module

3 AC Main Source

3 , f, V

3 Meter

3 , f, V VFD 24Vdc Motor

Fuzzy PID

DIFF

Temperature Parameter

Note: 3 meter can display wattage consumed to reflect motors energy consumption under different temperature parameters

Temperature Simulator and Sensor

Energy saving with variable speed motor control (30%-60% saving) Cooling tower motor, pumps motor, AHU, blower, compressor motor and more.

Inverter

DIFF Controller board Sensors Input

3 AC Main Source

3 , f, V, I

3 Meter

3 , f, V , I VFD 24Vdc Motor

RS-485

PID Parameter

PC
RJ-45 RS-485 RS-485

Intelligent Controller

Temperature Parameter

RS-485/RJ-45 Converter

RS-485 Hub

Note: Except wattage as in option 1, f, V, I and temperature can also be displayed on PC Two programs of control software are required to code and port on PC

Temperature Simulator and Sensor

Display % output Fuzzy PID Logic controller RS485 Modbus (future)

Inverter Ready Signal

Heating/Cooling

Alarm Output

RS232 programming

105mm
Ambient Temperature Low Temperature Motor Temperature

135mm
Humidity/Pressure Analog Input1 Humidity/Pressure Analog Input2 To Inverter Analog Output1&2 24Vdc Supply

DIFF

Fixed speed but varying load applications

Installation diagram with external bypass


AC IN R
CT1

S
CT2

T
CT3
Motor on-off remote control

Motor on-off indicator


Jogging
control

AC input for Indicator *


BYP COM

PAT-VC
R S T R
b

START COM STEP

S
MC BYPASS

T
a AC input for MC control **

* The voltage of the AC input for the indicator depends on the voltage of the indicator.

MOTOR

** The voltage of the AC input for the MC control depends on the voltage specification of the MC.

Application: Escalator
Speed: Constant Control: Motion Sensor Inveter Inverter: Speed reduces when nobody on escalator

Application: Escalator
Speed: Constant Control: Monitor current VC board: Speed remain when nobody on escalator. Voltage & Current reduces. 1ms response time when load return.

Application
Motor Size Average Savings Savings (down) Power Tariff Annual Saving (12hr x 365)

Escalator
40Hp (30kw) 35.75% 6.08kw to 4.00kw $0.30/kwh $2,628

SES-VT series
Feature:
Power Saving Efficiency: 10% Plug and Save, Easy to Install Multiple Power Protection functions Enhance anti-harmonic interference protection

Spec: 110-220Vac 1 , 10A / 15A Max Application: High Electrical consuming home appliances, e.g. refrigerator, washing machine, water pump, dehumdifier.
20

VS/VK mixed load energy saving Saving 18-25% Single or Three phase
Power Line

Utility Meter

NFB

Power Line- L1

NFB SES-VCS 50A/75A Power Line- N

NFB

NFB: Non-Fuse Breaker

NFB

NFB

SES-VTL series
Super Light Saving Adapter Feature:
Power Saving Efficiency: 10% Plug and Save, Easy to Install

Spec: 110-220Vac 1 , 10A / 15A Max Application: Home, Office, Building, Business Centre, Factory

24

Summary

DIFF

VR

VC

VS/VK

VT/VTL

Anda mungkin juga menyukai