Anda di halaman 1dari 52

MAINTENANCE PREVENTIVE

Steve Skinner, Eaton Hydraulics, Havant, UK Copyright

Eaton Hydraulics 2000

CIRCUIT HYDRAULIQUE

TIROIR dun DISTRIBUTEUR

JEU FONCTIONNEL DU TIROIR

5m

JEU FONCTIONNEL DU TIROIR

5m

EROSION

EROSION

POMPE A PISTONS AXIAUX

PISTON et CYLINDRE

Haute pression

Basse pression

PISTON et CYLINDRE

USURES

PISTON et CYLINDRE

PISTON et CYLINDRE

Communication entre la haute et la basse pression : fuites internes

DEFAILLANCES HYDRAULIQUE

Les mauvaises conditions de filtration sont lorigine denviron 70 90% des dfaillances hydrauliques

Problme de filtration

Autres problmes

DEFAILLANCES DES SYSTEMES HYDRAULIQUES

DEGRADATIONS SUR LE ROTOR DUNE POMPE A PALETTES

CIRCUIT HYDRAULIQUE

IMPURTEES CONTENUES DANS LE RESERVOIR

IMPURETES EN PROVENANCE DUN FUT DHUILE

CONTAMINATION LORS DUN CHANGEMENT DE COMPOSANT

CONTAMINATION LORS DUNE INSPECTION DU RESERVOIR

CONTAMINATION RELATIVE A LA DEGRADATION DU VERIN

DEGRADATION DE LA POMPE SUITE A UNE POLLUTION TROP IMPORTANTE

NIVEAU DE FILTRATION

NIVEAU REQUIS

FAIBLE POLLUTION NIVEAU ACTUEL

FORTE POLLUTION

PRELEVEMENT DUN ECHANTILLON DHUILE

MESURE DE LA CONTAMINATION

1 micron (m) = 0.000001 mtre = 0.001 millimtre

NIVEAU DE CONTAMINATION

CHEVEU POLLEN

GRAIN DE SEL

10

20

30

40

50 60 microns

70

80

90

100

ANALYSES DES PARTICULES

100 ml

CLASSIFICATION

>2m

>5m

> 15 m

COMPTEUR DE PARTICULES

The sample cylinder contains some fluid. Press FLUSH to drain

Target Pro

CO2

sfjdslj ;djg djg 0ad[g [jg i]0dig ]0d9ig 0d0g 00dg 099d =09 ]09 0ae9 00gi0 ]0d9]09 ]ierwEPO ]D0009 099 EUGE0 0E9JKO 00 909iiidsjr

COMPTEUR DE PARTICULES

CO2

The sample cylinder contains some fluid. Press FLUSH to drain

Target Pro

RAPPORT

>2m

>5m

> 15 m

Exemple: par ml

3250
VICKERS TARGET-PRO VICKERS TARGET-PRO

860

122

Sample: MACHINE 1 Sample: MACHINE 1 Date: 8.1.99 Date: 8.1.99 Sample Vol: 30ml Sample Vol: 30ml Flow rate: Flow rate: 50 --25 ml/min 50 25 ml/min Reported values: COUNTS // ml Reported values: COUNTS ml ISO: 22/17/13 ISO: 22/17/13 NAS: 8 NAS: 8 2m 2m 5 m 5 m 15 m 15 m 25 m 25 m 50 m 50 m 100 m 100 m MIN MIN 3214 3214 832 832 119 119 7 7 0 0 0 0 MAX MAX 3285 3285 887 887 124 124 12 12 1 1 0 0 AVG AVG 3250 3250 860 860 122 122 9 9 0 0 0 0

CLASSE ISO

Particules / 1 ml
0.01 0.02 0.04 0.08 0.16 0.32 0.64 1.3 2.5 5 10 20 40 80 160 320 640 1300 2500 5000 10000

Code ISO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

122 860 3250

ISO 4406 Code 19 / 17 / 14

COMPOSANTS et CLASSE de POLLUTION

RECOMMENDED ISO CLEANLINESS CODE CLASSE ISO de FILTRATION RECOMMANDE


P < 140 bar 20/18/15 20/18/15 18/16/14 P < 210bar 19/17/15 19/17/14 17/15/13 20/18/15 18/16/13 20/18/15 P > 210 bar 18/16/13 18/16/13 16/14/12 19/17/14 17/15/12 19/17/14

18/16/13 20/18/15 20/18/15

17/15/12 20/18/15

FILTRE HYDRAULIQUE

Particules Elment filtrant

FILTRE HYDRAULIQUE

FILTRE HYDRAULIQUE

Saturation des capacits du filtre

OUVERTURE DU CLAPET BY-PASS : PLUS DE FILTRATION

INDICATEUR DE COMMATAGE

INDICATEUR DE COMMATAGE VISUEL


Dtection du colmatage si la pression est > 3 bars

3 bars

INDICATEUR DE COMMATAGE ELECTRIQUE

INDICATEUR DE COMMATAGE ELECTRIQUE ET VISUEL

BOUCHON DE REMPLISSAGE FILTRE

BOUCHON DE REMPLISSAGE FILTRE

BOUCHON DE REMPLISSAGE FILTRE

BOUCHON DE REMPLISSAGE FILTRE

CIRCULATION de lair ambiant vers le reservoir


Elment filtrant

CIRCULATION de lair contenu dans le reservoir vers lexterieur

Elment filtrant colmat


Indicateur de colmatage

FILTRATION sur la CONDUITE DASPIRATION

FILTRATION sur la CONDUITE DASPIRATION

FILTRATION sur la CONDUITE DE REFOULEMENT

FILTRATION sur la CONDUITE DE RETOUR

FILTRATION EXTERNE

Anda mungkin juga menyukai