EXISTING AND NEW BUILDING

EAST ELEVATION
SCALE 1:250

ELEVATION KEY

Fifth Floor 22000mm

Fourth Floor 18000mm

Fourth Floor 18000mm

Third Floor 14000mm

Third Floor 14000mm

Second Floor 1000mm

Second Floor 1000mm

First Floor 6000mm Spandrel Panels Ground Floor 0mm

EXISTING AND NEW BUILDING

WEST ELEVATION
20000 9000

SCALE

1:250

ELEVATION KEY

3200

6100

Fifth Floor 22000mm

Fourth Floor 18000mm

2400

Fourth Floor 18000mm

Third Floor 14000mm

Third Floor 14000mm

Atrium
1

18000

Second Floor 2 1000mm

15000

Second Floor 1000mm

First Floor 6000mm

Curtain walling, 3m by 1m.

Ground Floor 0mm

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Ground Floor level taken from the southern side of the site.

16500

40000

16500

Double gabled roof with slate tiles


2110

Georgian double sash with thick glazing bars beneath a decorative gauged brick arch Raised cornice
400

2800

600

ELEVATION KEY
3

Third Floor 11700mm

18660

2
6000

Second Floor 8000mm

1900

1000

1400

2700

Existing Stonework To be retained as it is, any damaged parts will be repointed

First Floor 4000mm

EXISTING BUILDING

NORTH ELEVATION
SCALE 1:200

Portico Decorative Window

Six panel glass timber door

Ground Floor 0mm

Typical georgian chimney Double gabled roof

ELEVATION KEY ELEVATION KEY


3

ELEVATION KEY

Third Floor 11700mm

Third Floor 11700mm

Second Floor 8000mm

Second Floor 8000mm

1
5960

First Floor 4000mm

First Floor 4000mm

0
EXISTING BUILDING

Ground Floor 0mm

Ground Floor 0mm

0
EXISTING BUILDING

EAST ELEVATION
SCALE 1:200

WEST ELEVATION
SCALE 1:200

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Ground Floor level taken from the southern side of the site.

Curtain Walling 3m by 1m
1000

1000

40000

1050

Balcony area with 1100mm high handrail

3000

Spandrel Panels

400

Third Floor 14000mm

3600

1100

18000

Second Floor 1000mm

NEW OFFICE BUILDING

3600

Stonework to match existing building

SOUTH ELEVATION
SCALE 1:200

First Floor 6000mm

ELEVATION KEY

5600

Two double door entrance Ways leading into New Office Building
2700 3800 21500 6000 6000

3000

Ground Floor 0mm

6m by 3m car park entrance and exist. Allows for double flow of traffic.

750 1100

15000

4600

2150

ELEVATION KEY

Third Floor 14000mm

Third Floor 14000mm

1000

ELEVATION KEY

1100

Second Floor 1000mm

Second Floor 2 1000mm

400

First Floor 6000mm

First Floor 6000mm

5600

0
NEW OFFICE BUILDING

Ground Floor 0mm

Ground Floor 0 0mm


NEW OFFICE BUILDING

WEST ELEVATION
SCALE 1:200

2000

EAST ELEVATION
SCALE 1:200

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Shown here is the New Office Builidings South, East and West elevations.

ELEVATION KEY
NEW OFFICE BUILDING

SOUTH ELEVATION
SCALE 1:200

Fifth Floor 22000mm

Existing building shown behind the New Office building


4
Fourth Floor 18000mm

Third Floor 14000mm

Balcony area with 1100mm high handrail

Second Floor 1000mm

Balcony area with 1100mm high handrail

Curtain Walling 3m by 1m

First Floor 6000mm

Ground Floor 0mm

Stonework to match the existing building Two double door entrance Ways leading into New Office Building 6m by 3m car park entrance and exist. Allows for double flow of traffic.

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Ground Floor level taken from the southern side of the site.

NEW BUILDING

SECTION
SCALE 1:200

Roof Detail See Drawing Number DT01

Third Floor 14000mm

SECTION KEY

Section Through Floor at exterior wall see Drawing Number DT06


2

Second Floor 1000mm

First Floor 6000mm

Ground Floor 0mm

EXISTING BUILDING

SECTION
SCALE 1:200

Fifth Floor 22000mm

Fourth Floor 18000mm

SECTION KEY

Third Floor 14000mm

Second Floor 1000mm

Reception area with seatting and desk

Lift

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

Ex. Rafters Ex. Stonework 500mm thick, Consisting of 200mm sandstone, 100mm rubble , 200mm sandstone.

Fifth Floor 22000mm

Green Roof Detail See Drawing Number DT01


SECTION KEY

Fourth Floor 18000mm

Curtain Walling Detail See Drawing Number DT02

Third Floor 14000mm

Third Floor 14000mm

Second Floor 1000mm

Second Floor 1000mm

First Floor 6000mm

Ground Floor 0mm

Basement Wall Detail See Drawing Number DT05

Section Through Floor Showing Internal Partition See Drawing Number DT03

Section Through Floor At Beam See Drawing Number DT04

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

203x300x12mm End Plate

UC305 x 305 x 158 Kg/n

UC305 x 305 x 158 Kg/n

80x80x10 Angle Cleats 130 long dixed with 2No


5

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

C U 30

300 x 300 x 15 ASB End Plate


15 g 8k /n

x 30 5

350x350x40mm Baseplate Indented foundation bolts

Welded
DETAIL DRAWING

COLUMN TO FOUNDATION CONNECTION


SCALE 1:10 DETAIL DRAWING

COLUMN TO BEAM CONNECTION ELEVATION


SCALE 1:10

DETAIL DRAWING

COLUMN TO BEAM CONNECTION PLAN


SCALE 1:10

STEEL QUALITY TO COMPLY GENERALLY WITH BS.EN.10025 GRADE 5275. MATERIALS AND WORKMANSHIP TO BS 499 PT 2.

BOLTS AND NUTES GRADE 8.8 TO COMPLY WITH BS 4190 AND WASHERS TO BS 4320

Growing Medium (depth variable) Ballast

Thermal Insulation Cladding Rail

Nature Matt

See Detail Drawing 02

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

BS EN 13163 - Contains a flame-retardant additive

2200

1000 1400 1000 1400

5200

1400 1000 1400 1000

2000

990 1000 1400 1000 1400 1000 1400 1000

2150 2500 2500

2450

1000 1400 1000 1400 1000 1400 1000

16

5000

5500

R
EXISTING BUILDING

SECOND FLOOR
SCALE 1:200

N
2000 4850 4850

17

18

19

3200

4780

1800

3080

4950

19 VOID TO BELOW
R50 00

20

21

Room Schedule R - Reception Area 16 - Common Room 17 - Disabled Toilets 18 - Female Toilets 19 - Male Toilets 20 - Atrium Walkway 21 - Staff Room w/ kitchen 22 - Cleaners Room 23 - Storage Room 24 - Storage Room 25 - Managers Office 26 - Open plan office space 27 - Balcony Area 28 - Balcony Area

18

4850

17
1800

1300

Cleaners Trolley

4870

3280
Space for scrubbing or polishing equipment

22
Space for suction cleaner May require wall fittings

1300

600

800

Space for Cleaners Trolley

DN

UP

25 23 24

26

27

28

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Any interior furnishing shown for illustrative purposes only.

12mm toughened glass with 70mm cavity

Glass walling floor abutment Pedestal, height can be adjusted Field head cap screwed to floor panel 600x600mm full panel span

Access Floring Services(UK) Medium Grade JVP Panel 600x600x29mm

30
20mm x 9mm class 0 foam Slimdek SD225 deep decking

30

600

600

300

150

Deep composite steel decking (SD225)

350

20

Linear spot lighting

Service opening 160mm deep x 320mm long Knauf Amf Thermatex Alpha Mineral wool ceiling tiles 600x600x19mm

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

Raised Floor conforms to BS EN 12825 PSA Grade - Medium

90

EXISTING BUILDING

GROUND FLOOR
SCALE 1:200

LIFT

FF LIFT LIFT

Room Schedule 1 - Entrance area leading to first floor 2 - Male changing area with WC facility 3 - Female changing area with WC facility P - Parking Area

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

DN 6 UP
610 1750 1500 6140 1800 3200

15

5000

4850

7
EXISTING BUILDING

FIRST FLOOR
SCALE 1:200

5500

8
4850

Room Schedule
2000

Cleaners Trolley

1800

5230

1800

4200

1800

2370

14 DN UP

26

1300

30
18 00

10
Space for scrubbing or polishing equipment Space for suction cleaner May require wall fittings

600

800

Space for Cleaners Trolley

26

2530

11 12
6750

30

4 - Open planned office space 5 - Main food serving area with seating facilties 6 - Access core with stairway and two lifts 7- Male Toilets 8 - Females Toilets 9 - Disabled Toilets 10 - Cleaners Room 11 - Storage Area 12 - Storage Area 13 - Balcony Area 14 - Balcony Area 15 Staff Room w/ kitchen.

3250

1300

13
6370

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Any interior furnishing shown for illustrative purposes only.

4700

1100 1000

2830

2900

1300

UP 31 30 DN

EXISTING BUILDING

THIRD FLOOR
SCALE 1:200

29

32

33

34

1000

1800

2800

34 35 VOID TO BELOW 43

Room Schedule 29 - Open office space 30 - Male Changing Room 31 - Female Changing Room 32 - Disabled Toilets 33 - Female Toilets 34 - Male Toilets 35 - Atrium Walkway 36 - Balcony Area 37 - Managers Office 38 - Cleaners Room 39 - Storage Cupboard 40 - Storage Cupboard 41 - Balcony Area 42 - Open office space 43 - Staff Room w/kitchen
Space for Cleaners Trolley

33

32
4000 1800 3900

38 36 DN UP 37 39 40

42

41

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Any interior furnishing shown for illustrative purposes only.

UP 47 46 45 DN

EXISTING BUILDING

FOURTH FLOOR
SCALE 1:200

44

48

49

50

51 Room Schedule 44 - Open office space 45 - Managers Office 46 - Staff Room w/kitchen 47 - Common Room 48 - Disabled Toilets 49 - Female Toilets 50 - Male Toilets 51 - Atrium Walkway

VOID TO BELOW

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Any interior furnishing shown for illustrative purposes only.

UP 55 54 53 DN

EXISTING BUILDING

FIFTH FLOOR
SCALE 1:200

52

57 56

58

Room Schedule 52 - Open office space 53 - Managers Office 54 - Staff Room w/kitchen 55 - Common Room 56 - Disabled Toilets 57 - Female Toilets 58 - Male Toilets

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS Any interior furnishing shown for illustrative purposes only.

A8
7800

A7
7200

A6
5300

C5
7500

C4
7800

A3
7200

A2
7200

A1

ELEVATION KEY

TOS 21900mm

TOS 17900mm

TOS 13900mm

3500

3
4000

TOS 13900mm

TOS 9900mm

2
4000

TOS 9900mm

TOS 5900mm

6000

Ground Level 0mm

Column to foundation detail See Drawing Number DT07

For Column to beam connection detail See Drawing Number DT07

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS EXISTING FOUNDATIONS ARE TO BE RETAINED AND STRENGTHENED USING DIAGONAL PILING TOS = Top Of Steel

BOLTS AND NUTES GRADE 8.8 TO COMPLY WITH BS 4190 AND WASHERS TO BS 4320 STEEL QUALITY TO COMPLY GENERALLY WITH BS.EN.10025 GRADE 5275. MATERIALS AND WORKMANSHIP TO BS 499 PT 2.

7000

7200

7200

6 5300

7500

7800

7200

7200

U 30 C 5 x 30 5 15 8k n g/ C U 30 5 x 30 5 15 8k n g/ U C 30 5 x 30 5 8k 15 g/ n C U 30 5 x 30 5 15 8k g/ n U C 30 5 x 5 30 15 8k n g/ U 30 5 x 30 5 8k 15 g/ n C

C U

C U

280 ASB 100

U
280 ASB 100 280 ASB 100 280 ASB 100

30 C

30 C

30 C

30 C

C 30 5
280 ASB 100

30

30

5 x

x 5 30 15 g/ 8k n C U 30 5 x 30 5 15 8k n g/ C U 30 5 x 30 5 15 g/ 8k n U C 30 U 30 C C U 30 C U 30
280 ASB 100

30

30

30

280 ASB 100

30 5 15 8k n g/
280 ASB 100 280 ASB 100

30

30

280 ASB 100

5 15 8k n g/

280 ASB 100

15 8k n g/

15

280 ASB 100

15 8k n g/

15

280 ASB 100

8k n g/

280 ASB 100

g/ 8k n

C U 30 5 x 30 5 15 8k n g/ C U 30 5 x 30 5 15 g/ 8k n 5 x 5 30 15 g/ 8k n 5 x 30 5 15 8k g/ n 5 x 30

280 ASB 100

280 ASB 100

280 ASB 100

280 ASB 100

C U 30 5 x 30 5 15 8k n g/ C U 30 5 x 30 5 15 g/ 8k n U C 30 5 x 5 30 15 g/ 8k n C U 30 5 x 30 5 15 8k n g/ U 30 C

280 ASB 100

280 ASB 100

280 ASB 100

280 ASB 100

C U 30 5 x 30 5 15 8k n g/ C U 30 5 x 30 5 15 g/ 8k n U C 30 5 x 5 30 15 g/ 8k n U C 30 5 x 30 5 15 8k g/ n U 30 C

280 ASB 100

280 ASB 100

280 ASB 100

280 ASB 100

C U 30 5 x 30 5 15 8k n g/ C U 30 5 x 30 5 15 g/ 8k n U C 30 5 x 5 30 15 g/ 8k n U C 30 5 x 30 5 15 8k g/ n U C 30

280 ASB 100

280 ASB 100

280 ASB 100

280 ASB 100

C U 30 5 x 30 5 15 8k n g/ C U 30 5 x 30 5 15 g/ 8k n U C 30 5 x 5 30 15 g/ 8k n U 30 C 5 x 30 5 15 8k g/ n U 30 C

280 ASB 100

280 ASB 100

280 ASB 100

280 ASB 100

C U 30 5 x 30 5 15 8k n g/ C U 30 5 x 30 5 15 g/ 8k n U C 30 5 x 5 30 15 g/ 8k n U C 30 5 x 30 5 15 8k g/ n U 30 C

5 x 30 5 15 8k g/ n U C 5 30 x 30 5 8 15 kg /n U C 30 5 U C 30

280 ASB 100

5 15 8k g/ n U
280 ASB 100

280 ASB 100

x 30 5 15 8k g/ n U

30

280 ASB 100

30 5 15 8k g/ n U

30

30

280 ASB 100

5 15 8k g/ n U

280 ASB 100

5 15 8k g/ n U

280 ASB 100

15 8k g/ n

C U 30 5 x 30 5 15 g 8k /n
5

280 ASB 100

C 5 30 x 30 5 15 8k g/ n U C 30 5

280 ASB 100

5 30 x 30 5 8k 15 g/ n U C 5 30

280 ASB 100

30 5 x 5 30 15 8k n g/ U U C 30 5

280 ASB 100

30 5 x 5 30 15 8k n g/ C 5 30 x

280 ASB 100

30 5 x 5 30 15 8k n g/

For Column to beam connection detail See Drawing Number DT06


x 30 5 8k 15

U C 30 5

3900 A B

x 30 5 8k 15 g/ n

280 ASB 100

6000 C

x 30 5 8k 15 g/ n

280 ASB 100

6000 D

x 30 5 15 8k g/ n

280 ASB 100

x 5 30 8 15 kg /n

30

280 ASB 100

30 5 15 8k g/ n

280 ASB 100

5 8k 15 n g/

g/ n

280 ASB 100

5600 E

5900 F

6300 G

5700 H

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS EXISTING FOUNDATIONS ARE TO BE RETAINED AND STRENGTHENED USING DIAGONAL PILING

BOLTS AND NUTES GRADE 8.8 TO COMPLY WITH BS 4190 AND WASHERS TO BS 4320 STEEL QUALITY TO COMPLY GENERALLY WITH BS.EN.10025 GRADE 5275. MATERIALS AND WORKMANSHIP TO BS 499 PT 2.

INTERIOR

EXTERIOR

INTERIOR

EXTERIOR

Sealant Glass Panel

Steel Beam Purpose made bracket fixed to mullion via M10 bolts, holes to be slotted to allow for linear movment Suspended Ceiling Roof Tile Anti-Rotational Bracket

Glass Panel

DETAIL DRAWING

CURTAIN WALLING AT HEAD


DETAIL DRAWING SCALE 1:10

CURTAIN WALLING AT INTERMEDIATE FLOOR


SCALE 1:10

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

SEE DETAIL DRAWING DT01 FOR ATTACHMENT OF HEAD TO ROOF

Secent Wall piling covers the length of the existing building and then extends out halfway towards the atrium.

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

Indicates position of foundation piling ALL FOUNDATIONS FORMATIONS TO BE INSPECTED AND APPROVED BY THE STRUTURAL ENGINEER
EXISTING BUILDING FOUNDATIONS ARE TO BE RETAINED AND STRENGTHENED USING DIAGONAL PILING

Sheating Board

Breather Paper Access Floring Services(UK) Medium Grade JVP Panel 600x600x29mm

Cladding on angle brackets

External Cladding

Linear Spot Lighting Deflection head Deep composite steel decking (SD225)

15mm plasterboard resilient strip Acoustic Sealant Knauf Amf Thermatex Alpha Mineral wool ceiling tiles 600x600x19mm

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

BS EN 12464-1. Light and lighting. Lighting of work places. Part 1. Indoor work places

Access Floring Services(UK) Medium Grade JVP Panel 600x600x29mm

A142 Mesh Reinforcement Connection Crown of decking is fixed to top of end diaphragm screws Reinforcement To Engineers Specification

End diaphragm Composite Slimflor Beam

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

Closed Cell Insulation, eg Knauf

EXTERIOR

INTERIOR

Stent Pilling

12.5mm Plasterboard Dryling

Oldroyd Xs Membrane

Floor Screed 50mm

Knauf Polyfoam Floorboard

Oldroyd Xv20 Membrane (Fill studs with Lean-Mix Concrete)

Reinforced Concrete Slab

Vandex Super - Used As Lime Control Agent

Steel Reinforcement

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

This drawing shows the internal tanking method that will be used to keep water out from the basement.

S 1

E 3

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

Letters and numbers inside the circle indicates drawing number

E 3 E 1 S 1

ALL DIMENSIONS IN MM UNLESS OTHERWISE SPECIFIED. THESE DRAWINGS ARE NOT WORKING DRAWINGS AND SHOULD BE VERIFIED BY A PROFESSIONALLY QUALIFED ENGINEER OR ANOTHER PROFESSIONAL BODY BEFORE USE DO NOT SCALE FROM THESE DRAWINGS

Arrows indicate direction of rainfall upon the roofing.