Anda di halaman 1dari 2

TABLE

CALCULATION SHEET FOR HORIZONTAL DRUM

* EQUIPMENT ITEM
*
OPERATING PRESSURE
*
OPERATING TEMPERATURE
*
*

*
*

(BAR-G)
(DEG-C)

30-V602
0.023
4

(KG/HR)
(KG/M3)
(M3/HR)
(M3/SEC)

0.00
35.703
0.00
0.00

(KG/HR)
(KG/M3)
(M3/HR)
(M3/MIN)

67735.00
1129
60.00
1.00

(MIN)
(M3)

12.5
12.50

(-)

2.5

(3.0)

/ DIA
/ DIA

0.1
0.5

(0.2)
(0.5)

/ DIA
/ DIA

0.0520
0.5000

PROCESS DATA
VAPOR
FLOW RATE
DENSITY
VOLUME FLOW
LIQUID

FLOW RATE
DENSITY
VOLUME FLOW

HOLDING TIME
NORMAL HOLD UP

TL-TL / VESSEL ID

(NLL to LLL)

LEVEL HEIGHT RATIO


*
*

H(LLL)
H(NLL)
CROSS SECTIONAL AREA RATIO
A(LLL)
A(NLL)

*
*

*
*

(0.1424)
(0.5)

CALCULATED VESSEL I.D.


CALCULATED TL-TL LENGTH

(MM)
(MM)

2,416
6,088

TAKE

(MM)
(MM)

2,500
6,300

TOTAL VESSEL VOL / SURF


CYLINDER VOL / SURF
ELLIPS HEAD VOL / SURF

(M3 / M2)
(M3 / M2)
(M3 / M2)

35.016
30.925
4.091

CROSS SECTIONAL AREA(At)

(M2)

4.909

LIQUID LEVEL FROM BOTTOM


X2
X1

(MM)
(MM)

400
600

600
1,300

1,300
2,100

X1-X2 TOTAL LIQ. VOLUME


X1-X2
CYLINDER VOLUME
X1-X2 ELLIPS HEAD VOLUME

(M3)
(M3)
(M3)

2.827
2.513
0.313

12.117
10.543
1.574

13.123
11.481
1.642

LIQUID HOLDING TIME

(MIN)

2.83

12.12

13.12

(M2)
(M/SEC)

4.003
0.00

2.329
0.00

0.507
0.00

(< 0.10)
(< 0.15)

0.000

0.000

0.000

(MM)

IN(FEED)
150.19
95.93

OUT(GAS)
0.00
0.00

OUT(LIQ)
145.67
145.67

VESSEL I.D.
TL-TL LENGTH

GAS CROSS SECTIONAL AREA


CROSS FLOW VELOCITY
VOLUME LOAD FACTOR / AREA
KNOCK-OUT DRUM TYPE
DEMISTER VESSEL TYPE
MIN.REQUIRED NOZZLE I.D.
KNOCK-OUT DRUM TYPE
DEMISTER VESSEL TYPE
NOTE

DP : 3.5 barg, DT : 82 deg-C


MATERIAL : CS WITH EPOXY COATING
SPACE FOR LEVEL INSTRUMENTS (150 MM) IS CONSIDERED IN VESSEL ID
VAPOR SPACE IS CONSIDERED IN VESSEL ID

59.290
49.480
9.810

3/31/2013

2,100
2,100
0.000
0.000
0.000
0.00
0.507
0.00
0.000

Anda mungkin juga menyukai