Anda di halaman 1dari 75

CONCRETE MIX DESIGN

BUILDING TECHNOLOGY AND MANAGEMENT

INTRODUCTION
Concrete is obtained by mixing cement, fine aggregate, coarse aggregate, water and admixtures in required proportions. The mixture when placed in forms and allowed to cure becomes hard like stone.

The hardening is caused by chemical action between water and


the cement due to which concrete grows stronger with age.

It is the most widely-used man-made construction material in the world.


CONCRETE MIX DESIGN 2

CONCRETE MAKING MATERIALS


Cement Aggregates Water Admixtures

CONCRETE MIX DESIGN

CEMENT
Cement and water forms the active component of concrete, while the inactive group comprises the fine and coarse aggregates. The cement and water form a paste that hardens and bonds the aggregates together. Types of Cement Although around 18 types of cements are recognized by BIS, more commonly used ones are: Ordinary Portland Cement 33, 43, & 53 grade OPC, Blended Cements (PPC and PSC). Sulphate Resisting Cement (SRC), Low Heat Portland Cement (LHPC), Hydrophobic Portland Cement, Colored Cement (White Cement).
CONCRETE MIX DESIGN 4

AGGREGATES
They are cheaper than cement and impart greater volume stability and durability to concrete. The main purpose is to provide bulk to the concrete. Some of the aggregates may be chemically active. CLASSIFICATION Geological origin natural and artificial Size fine, coarse and all-in Shape rounded, irregular, angular, flaky and elongated Unit weight normal-weight, heavyweight and lightweight

CONCRETE MIX DESIGN

WATER
The most important and least expensive ingredient of concrete. One part of the water is used in the hydration of cement to form the binding matrix. The remaining water affords lubrication and workability to the concrete. Water-cement ratio depends on the grade of concrete, its workability, durability, nature and type of aggregates etc. Potable water is ideal for concreting. Seawater may be used in PCC.

CONCRETE MIX DESIGN

ADMIXTURES
Added to the concrete immediately or during mixing to modify its properties in the fresh or hardened state.

Types: Accelerators - speed up the initial set of concrete. Retarders delay the setting time of concrete mix. Plasticizers and Super-plasticizers - water reducers. Air entraining admixtures Water proofers Pigments Corrosion-inhibiting chemicals Antifungal admixtures

CONCRETE MIX DESIGN

TYPES OF CONCRETE MIXES


1. NOMINAL MIX Mixes of fixed proportions, IS:456-2000 permits nominal mixes for concretes of strength M20 or lower DESIGN MIX Designed on the basis of requirements of the concrete in fresh and hardened states.

2.

CONCRETE MIX DESIGN

TRIAL MIXES Prepared to verify whether the Design Mix would perform as per the assumptions. If appreciable variation exists, the available alternatives are:
1. directly employ the trial mix proportions at the site 2. modify the trial mix proportions on the basis of intuition and employ the revised proportions at the site 3. prepare further trial mixes incorporating changes in the proportions based on the feedback generated from the previous mix.

CONCRETE MIX DESIGN

CONCRETE MIX DESIGN


DEFINITION

Mix Design is the science of determining the relative proportions of the ingredients of concrete to achieve the

desired properties in the most economical way.

CONCRETE MIX DESIGN

10

PRINCIPLES OF MIX DESIGN


1 2 The environment exposure condition for the structure The grade of concrete, their characteristic strengths and standard deviations 3 4 5 6 7 8 The type of cement The types and sizes of aggregates and their sources of supply The nominal maximum sizes of aggregates Maximum and minimum cement content in kg/m3 Water cement ratio The degree of workability of concrete based on placing conditions
CONCRETE MIX DESIGN 11

Air content inclusive of entrained air

10 The maximum/minimum density of concrete 11 The maximum/minimum temperature of fresh concrete

12 Type of water available for mixing and curing


13 The source of water and the impurities present in it.

CONCRETE MIX DESIGN

12

IS 456:2000

CONCRETE MIX DESIGN

13

IS 456:2000

CONCRETE MIX DESIGN

14

IS 456:2000

CONCRETE MIX DESIGN

15

FACTORS DEFINING THE CHOICE OF MIX PROPORTIONS


1. 2. 3. 4. 5. Compressive Strength Workability Durability Type, size and grading of aggregates Aggregate-cement ratio

CONCRETE MIX DESIGN

16

COMPRESSIVE STRENGTH Abrams Law


log F = log A1 x log B1 where F is the compressive strength A1, B1 are constants and x is the w/c ratio by weight

CONCRETE MIX DESIGN

17

WORKABILITY
that property of freshly mixed concrete which determines the ease and homogeneity with which it can be mixed, placed,

consolidated and finished.

DURABILITY

the resistance to weathering action due to environmental


conditions such as changes in temperature and humidity, chemical attack, abrasion, frost and fire.

CONCRETE MIX DESIGN

18

REQUIREMENTS AND TESTS OF MATERIALS REQUIRED FOR MIX DESIGN


ASSIGNMENT # 1 TO BE SUBMITTED BY 07-02-2011 Roll #s 01-21 Cement Roll #s 22-42 Aggregates Roll #s 43-63 Water and Admixtures

CONCRETE MIX DESIGN

19

METHODS OF CONCRETE MIX DESIGN


1. 2. 3. 4. 5. 6. 7. 8. American Concrete Institute Committee 211 method Bureau of Indian Standards Recommended method IS 10262-82 Road note No. 4 (Grading Curve) method Department Of Environment (DOE - British) method Trial and Adjustment Method Fineness modulus method Maximum density method Indian Road Congress, IRC 44 method

CONCRETE MIX DESIGN

20

American Concrete Institute Method of Mix Design


(a) Data to be collected : (i ) Fineness modulus of selected F.A. (ii ) Unit weight of dry rodded coarse aggregate. (iii ) Sp. gravity of coarse and fine aggregates in SSD condition (iv ) Absorption characteristics of both coarse and fine aggregates. (v ) Specific gravity of cement. (b) From the minimum strength specified, estimate the average design strength by using standard deviation. (c) Find the water/cement ratio from the strength and durability points of view. Adopt the lower value.
CONCRETE MIX DESIGN 21

(d) Decide the maximum size of aggregate to be used. Generally for RCC work 20 mm and pre-stressed concrete 10 mm size are used.
(e) Decide workability in terms of slump for the given job. (f ) The total water in kg/m3 of concrete is determined, corresponding to the selected slump and selected maximum size of aggregate. (g ) Cement content is computed by dividing the total water content by the water/cement ratio.

(h) Select the bulk volume of dry rodded coarse aggregate per unit volume of concrete, for the particular maximum size of coarse aggregate and fineness modulus of fine aggregate.
CONCRETE MIX DESIGN 22

( j ) The weight of C.A. per cubic meter of concrete is calculated by multiplying the bulk volume with bulk density.
(k ) The solid volume of coarse aggregate in one cubic meter of concrete is calculated by knowing the specific gravity of C.A. (l ) Similarly the solid volume of cement, water and volume of air is calculated in one cubic meter of concrete.

(m) The solid volume of FA is computed by subtracting from the total volume of concrete the solid volume of cement, CA, water and entrapped air. (n) Weight of fine aggregate is calculated by multiplying the solid volume of fine aggregate by specific gravity of F.A.

CONCRETE MIX DESIGN

23

ACI METHOD: DESIGN EXAMPLE 1 Design a concrete mix for the construction of an elevated water tank. The specified design strength of concrete (characteristic

strength) is 30 MPa at 28 days measured on standard cylinders.


Standard deviation can be taken as 4 MPa. The specific gravity of FA and C.A. are 2.65 and 2.7 respectively. The dry rodded bulk density of C.A. is 1600 kg/m3, and fineness modulus of FA is 2.80. Ordinary Portland cement (Type I) will be used. A slump of 50 mm is necessary. C.A. is found to be absorptive to the extent of 1% and free surface moisture in sand is found to be 2 per cent. Assume any other essential data.

CONCRETE MIX DESIGN

24

1 Mean Cylinder Compressive Strength Assuming 5 per cent of results are allowed to fall below specified design strength, The mean strength, fm= fmin + ks = 30 + 1.64 x 4 = 36.5 MPa

Water/cement ratio
Strength criteria Durability criteria

CONCRETE MIX DESIGN

25

Strength Criteria

CONCRETE MIX DESIGN

26

Durability Criteria

CONCRETE MIX DESIGN

27

Mixing Water Content

Slump = 50 mm Maximum size of aggregate = 20 mm Concrete is non air-entrained

CONCRETE MIX DESIGN

28

CONCRETE MIX DESIGN

29

The mixing water content is 185 kg/m3 of concrete The approximate entrapped air content is 2%.

The required cement content =185/0.47 = 394 kg/m3

CONCRETE MIX DESIGN

30

Bulk Volume of C.A.

Maximum size of C.A = 20mm


Fineness Modulus of F.A. = 2.80 Find the dry rodded bulk volume of C.A.

CONCRETE MIX DESIGN

31

CONCRETE MIX DESIGN

32

The dry rodded bulk volume of C.A. = 0.62 per unit volume of concrete

The weight of C.A. = 0.62 x 1600


= 992 kg/m3

CONCRETE MIX DESIGN

33

The first estimate of density of fresh concrete = 2355 kg/m3

CONCRETE MIX DESIGN

34

Weight of FA

The weight of all the known ingredients of concrete Weight of water = 185 kg/m3

Weight of cement = 394 kg/m3 Weight of C.A. Weight of F.A. = 992 kg/m3 = 2355 (185 + 394 + 992) = 784 kg/m3

CONCRETE MIX DESIGN

35

Alternatively, the weight of F.A. can be determined by the more

accurate absolute volume method


Absolute Volume = weight/(1000) m3

CONCRETE MIX DESIGN

36

Total absolute volume = 697 x 103 cm3

Absolute volume of F.A. = (1000 697) x 103 = 303 x 103 Weight of FA = 303 x 2.65 = 803 kg/m3

CONCRETE MIX DESIGN

37

7 Estimated quantities of materials per cubic meter of concrete are:

Cement = 394 kg F.A = 803 kg C.A = 992 kg Water = 185 kg

CONCRETE MIX DESIGN

38

Proportions

C : F.A : C.A : water 394 : 803 : 992 : 185 1 : 2.04 : 2.52 : 0.47 Weight of materials for one bag mix in kg = 50 : 102 : 126 : 23.5

CONCRETE MIX DESIGN

39

9 The above quantities is on the basis that both F.A and C.A are in saturated and surface dry condition (SSD conditions).

FA has surface moisture of 2% Total free surface moisture in FA = (2/100 x 803) = 16.06 kg/m3 Weight of F.A in field condition = 803 + 16.06 = 819.06 kg/m3

CONCRETE MIX DESIGN

40

C.A absorbs 1% water


Quantity of water absorbed by C.A. = (1/100 x 992) = 9.92 kg/m3 Weight of C.A in field condition = 992 9.92

= 982 kg/m3
Change in Water Content

Water contributed by F.A Water absorbed by C.A. Extra water contributed by aggs. Total water content

= 16.06 kg = 9.92 kg = 16.06 9.92 = 6.14 kg = 185.00 6.14 = 179 kg/m3

CONCRETE MIX DESIGN

41

Quantities of materials to be used in field, corrected for free surface moisture in F.A and absorption characteristic of C.A

Cement F.A. C.A. Water

= 394 kg/m3 = 819 kg/m3 = 982 kg/m3 = 179 kg/m3

Field density of fresh concrete = 2374 kg/m3

CONCRETE MIX DESIGN

42

2. A mix with a mean 28-day compressive strength of 35 MPa and


a slump of 50 mm is required, using OPC. The maximum size of well shaped, angular aggregate is 20mm, its bulk density is 1600 kg/m3 and its specific gravity is 2.64. The available fine aggregate has a fineness modulus of 2.60 and a specific gravity of 2.58. No air-entrainment is required.

Water/Cement ratio

As durability criteria is not mentioned, consider strength alone

CONCRETE MIX DESIGN

43

Strength Criteria

CONCRETE MIX DESIGN

44

Water/cement ratio =0.48


Slump = 50 mm

Max size of aggregate = 20 mm

Determine water content

CONCRETE MIX DESIGN

45

CONCRETE MIX DESIGN

46

CONCRETE MIX DESIGN

47

Composition of concrete (kg/m3)

Water

185

Cement
CA FA

=
= =

386
1020 738

Density of Concrete

2329 (kg/m3)

CONCRETE MIX DESIGN

48

ROAD NOTE No. 4 METHOD OF MIX DESIGN


Proposed by the Road Research Laboratory, UK (1950)
Procedure: 1. The average compressive strength of the mix to be designed is obtained by applying control factors to the minimum compressive strength 2. Water/cement ratio is read from compressive strength v/s w/c

ratio graph
3. Proportion of combined aggregates to cement is determined from tables, for maximum size 40 mm and 20 mm

4. If the aggregate available differs from the standard gradings,


combine FA and CA so as to produce one of the standard gradings
CONCRETE MIX DESIGN 49

5. The proportion of cement, water, FA and CA is determined


from knowing the water/cement ratio and the aggregate/cement ratio. 6. Calculate the quantities of ingredients required to produce 1 m3 of concrete, by the absolute volume method, using the specific gravities of cement and aggregates.

CONCRETE MIX DESIGN

50

DRAWBACKS OF ROAD NOTE NO. 4 METHOD 1. Cannot be used directly for the design of air - entrained concrete

2. No recommendations for durability or strength, regarding the


water/cement ratio 3. The design tables refer to mixes in which the FA and CA are of the same shape 4. In selecting aggregate/cement ratio, only 3 shapes of aggregates and 4 gradings are recommended.

CONCRETE MIX DESIGN

51

DOE METHOD OF MIX DESIGN


Can be used for concrete containing fly ash. PROCEDURE 1. Target mean strength is calculated 2. Select water/cement ratio, from the type of cement and CA. Compare this with the ratio from durability conditions. 3. Decide the water content for required workability 4. Compare the cement content with the minimum cement content value and adopt the higher value 5. Find out the total aggregate content 6. Determine the proportion of FA using the appropriate FA% v/s CA size graph, and find the weight of CA and FA 7. Work out a trial mix.

CONCRETE MIX DESIGN

52

BIS RECOMMENDED MIX DESIGN METHOD


The BIS recommended mix design procedure is covered in IS 10262-82. In line with IS 456-2000, the first revision IS 10262-2009 was published, to accommodate some of the following changes: Increase in strength of cement Express workability in terms of slump, rather than the compacting factor Extend the W/C ratio v/s compressive strength graph

CONCRETE MIX DESIGN

53

Modifications in IS 10262-2009

CONCRETE MIX DESIGN

54

MIX DESIGN BASED ON IS RECOMMENDATIONS


Based on IS 10262:1982

Procedure:
1. Target mean strength for mix design:

fck* = fck + tS
where fck = characteristic compressive strength at 28 days S = standard deviation t = a statistical value depending on the risk factor.

CONCRETE MIX DESIGN

55

CONCRETE MIX DESIGN

56

CONCRETE MIX DESIGN

57

2. Selection of Water/Cement ratio

CONCRETE MIX DESIGN

58

3. Estimation of Entrapped Air

CONCRETE MIX DESIGN

59

4. Selection of Water Content and Fine to Total Aggregate ratio

CONCRETE MIX DESIGN

60

CONCRETE MIX DESIGN

61

5. Calculation of Cement Content:


cement by mass = Water content/Water cement ratio To be checked against the minimum cement content for the requirement of durability and the greater of the two values to be adopted.

CONCRETE MIX DESIGN

62

6. Calculation of aggregate content:

CONCRETE MIX DESIGN

63

7. Actual quantities required for mix Adjust the mix for deviations from assumed conditions

8. Check the calculated mix proportions

CONCRETE MIX DESIGN

64

DESIGN EXAMPLE: BIS RECOMMENDED METHOD

Grade M20
(a ) Design stipulations

(i ) Characteristic compressive strength


required in the field at 28 days - 20 MPa (ii ) Maximum size of aggregate - 20 mm (angular) (iii ) Degree of workability - 0.90 compacting factor

(iv ) Degree of quality control - Good


(v ) Type of Exposure - Mild

(b) Test data for Materials (i ) Specific gravity of cement - 3.15 (ii ) Compressive strength of cement at 7 days - Satisfies the requirement of IS: 2691989 (iii ) 1. Specific gravity of coarse aggregates - 2.60 2. Specific gravity of fine aggregates - 2.60

(iv ) Water absorption: 1. Coarse aggregate - 0.50% 2. Fine aggregate - 1.0% (v ) Free (surface) moisture: 1. Coarse aggregate - Nil 2. Fine aggregate - 2.0%

Design Procedure
1. Target mean strength of concrete fck* = fck + tS

fck = 20, t = 1.64 , S = 4

fck* = 26.6 MPa

CONCRETE MIX DESIGN

67

2. Selection of Water/Cement Ratio

CONCRETE MIX DESIGN

68

Durability Criteria: Mild Exposure Conditions

CONCRETE MIX DESIGN

69

W/C ratio from strength considerations = 0.50 W/C ratio from durability considerations = 0.55

Adopt the lower value

CONCRETE MIX DESIGN

70

3. Selection of water and sand content

CONCRETE MIX DESIGN

71

Adjustments in Water and Sand Contents

CONCRETE MIX DESIGN

72

4. Determination of cement content Water-cement ratio = 0.50 water = 191.6 kg/m3

Cement = 191.6/0.50 = 383 kg/m3

Is this satisfactory for mild exposure condition?

CONCRETE MIX DESIGN

73

5. Determination of coarse and fine aggregate contents Specified max. size of aggregate = 20 mm Corresponding entrapped air = 2%

fa = 546 kg/m3, Ca = 1188 kg/m3

CONCRETE MIX DESIGN

74

Final Mix Proportions


Water 191.6 Cement 383 FA 546 CA 1188

0.50

1.425

3.10

CONCRETE MIX DESIGN

75

Anda mungkin juga menyukai