AKC SERS
AKC-01A / AKC-03A AIRI AKIM KORUMA RLES
Genel
AKC-01A / AKC-03A Ar Akm Koruma Rlesi; motorlar ve sistemleri ar akma kar korumak iin tasarlanmtr. Bir akm ayar (Iset) ve iki gecikme ayarna (balama ve bekleme) sahiptir. Balama (start) gecikmesi, motor kalk (demeraj) akm nedeniyle oluabilecek hatal amalar nlemek amacyla gelitirilmitir. AKC-01A / AKC-03A motor veya koruduu sistemin akmn ler ve bu llen akm deeri ayarlanan akmn (Iset) zerindeyse motoru veya koruduu sistemi devreden karmak iin kullanlr. Akm Iset deerinin altnda ise k rlesi ekili (ON) konumdadr. ayet akm Iset deerinin zerinde bir deere ularsa ayarlanabilir bir bekleme gecikmesi sonunda rle brakr (OFF) ve bal olduu motoru veya sistemi devreden karr. Aadaki grafiklerde bu durumlar aklanmtr. Akm deeri Iset deerini atnda, motor veya sistemin kalk (start) akm etkisi ile hatal amas 1-6 sn ayarl balama (start) gecikmesi ile nlenir.
l k 2 AKC-01A/D
5 4 3 6 t(s) start 2 1
2 1 3
T1
l k 23 1 T1
T1
ON
OUT
I>Iset
alma Prensibi
Stop
1.5
2.5 3 t(s)
5 Iset 1 0.5
0.5
Start
C1
L1
Stop Start C1 N L1
L1 L2 L3 N
AKC-01A AKC-01D
T1
k K I L
Un
L1 L2 L3 N
k K
I L
C1
N
Un
C1
N 3~
M
3~
Tip PK 25
Tip PK 28
Genel
l k 2 AKC-03A/D
5 4 3 6 t(s) start 2 1
k
k K
T1
2 1 3
l k 23 1 T1
L
T1
ON
12x 9x 6x
OUT
15x Iset
I>Iset
Stop
1.5
2.5 t(s)
0.5
3x
1.5x
Start
C1
L1
Stop Start C1 N L1
L1 L2 L3 N
AKC-03A AKC-03D
CT-25
T1
k K I L
alma Prensibi
Un
L1 L2 L3 N
k K
I L
C1
N
CT-25
M
Un
C1
N 3~
M
3~
Tip PK 25
Tip PK 28
Tablo 1e gre
AKC-03 Serisi cihaz 2-20A aralnda kullanacaksanz; Akmn getii kabloyu CT-25 akm trafosuna 3 tur sarn, bu esnada ndeki Iset skalas u deerleri alacaktr. 1,5x=2A, 3x=4A, 6x=8A, 9x=12A, 12x=16A, 15x=20A
AKC-03A / AKC-03D sadece CT-25 akm trafosu ile kullanlr. Optimum zme ulamak iin; CT-25 akm trafosunu yandaki verilen akm aralklarnda ve tur saylarnda kullannz.
I Set Skalas
Akm Aral
Tur Says
Motor Akm
Ar Akm Koruma Rlesi (AKC-01A/03A) Balama Akm Akma Duyarl Ar Akm Durumu Normal (Normal Akmdan Fazla) Rle Gecikmeden alma Sonra Motoru Durdurur. Akm (Rle: OFF)
Teknik Bilgi
letme Gerilimi (Un) letme Aral letme Frekans Akm Ayar Aral Akm Trafosu evirme Oran : Cihazn zerindeki etikete baknz. : (0.9 -1.1) x Un : 50 / 60 Hz : 0.5 - 5A(AC) AKC-03 serisi iin tablo 1e baknz
Yksek Akm Ayar (Iset)
Balang Gecikmesi
Bekleme Gecikmesi
Gecikme Balangc
Gecikme Sonu
Zaman
: .../ 5A (AKC-01A/AKC-01D iin) : CT-25 (AKC-03A/AKC-03D iin) Balama Gecikmesi : 1 - 6 sn. Bekleme Gecikmesi : 0.5 - 2.5 sn. k Kontaklar : 1 C/O, 8A, 2000 VA, Cosj=1 Ortam Scakl : -5 0C ; +55 0C Koruma Snf : IP 20 Boyutlar : Tip PK 25 Balant ekli : Pano iine dikey veya klemens rayna Arlk : 0.3 kg
Motor Akm
Gecikme Balangc
Gecikme Sonu
Zaman
Boyutlar
58 mm
16mm
90 mm
35 mm
TP PK25
45 mm 62 mm
DKKAT: CT-25 Akm trafosunun ierisinden 1den fazla tur geirilecekse izolasyonlu kablo kullannz. CT-25 Akm trf. cihazla birlikte satlmaktadr.
Gvenli Kullanm ve Kurulum in Uyarlar
Aadaki talimatlara uyulmamas halinde yaralanma veya lmle sonulanabilecek durumlar ortaya kabilir. Cihaz zerindeki herhangi bir ilemden nce tm besleme gerilimlerini kesiniz. Cihaz ebekeye bal iken n paneli karmaynz. Cihaz solvent veya benzeri maddelerle temizlemeyiniz. Cihaz temizlemek iin sadece kuru bez kullannz. Cihaz altrmadan nce balantlarnn doru olduunu kontrol ediniz. Cihaz panoya monte ediniz. Cihaznzdaki herhangi bir sorunda yetkili satcnzla temas kurunuz . Yukardaki nlemlerin uygulanmamas sonucu doabilecek istenmeyen durumlardan retici firma hi bir ekilde sorumlu tutulamaz.
43mm
15.5mm
TP PK 28
2x0,35mm2 500mm
32 mm 48 mm
35 mm
CT-25
Bu rn, 30.05.2008 tarih ve 26891 sayl resmi gazetede yaynlanan EEE Ynetmeliinin Madde 2 ve Ek-1A madde 9 kapsamndadr.
A2842/Rev.4
l k 2 AKC-01A/D
5 4 3 6 t(s) start 2 1
2 1 3
Operation Principles
T1
l k 23 1 T1
T1
ON
OUT
I>Iset
AKC-01A device measures the current of motor or protected systems and are utilized to turn-off the motor or protected systems when measured current is above the adjusted level. When the current value is lower than Iset value, the output relay is switched on. When the current value becomes higher than Iset value, the output relay is switched off after an adjustable tripping delay time and the motor or protected system is turned off. Please see following figures. For circumstances that the current value becomes higher than Iset value, start-up delay (adjustable: 1-6 sec. ) is developed in order to prevent false contact turn-off arising from initial motor start-up currents.
Stop
1.5
2.5 3 t(s)
5 Iset 1 0.5
0.5
Start
C1
L1
Stop Start C1 N L1
L1 L2 L3 N
AKC-01A AKC-01D
T1
k K I L
Un
L1 L2 L3 N
k K
I L
C1
N
Un
C1
N 3~
M
3~
Type PK 25
Type PK 28
AKC-01D / AKC-03D Under Current Monitoring Devices are designed to protect motors and systems against under current with a current adjustment and two delay adjustments (start-up and tripping). Start-up delay is developed in order to prevent false contact turn-off arising from initial motor start-up (demurrage) currents.
l k 2 AKC-03A/D
5 4 3 6 t(s) start 2 1
2 1 3
l k 23 1 T1
L
T1
ON
12x 9x 6x
OUT
15x Iset
I>Iset
Stop
1.5
2.5 t(s)
0.5
3x
1.5x
Start
C1
L1
Stop Start C1 N L1
L1 L2 L3 N
AKC-03A AKC-03D
CT-25
Operation Principles
T1
k K I L
AKC-01D / AKC-03D device measures the current of motor or protected systems and are utilized to turn-off the motor or protected systems when measured current is below the adjusted level. When the current value is higher than Iset value, the output relay is switched on. When the current value becomes lower than Iset value, the output relay is switched off after an adjustable tripping delay time and the motor or protected system is turned off. Please see following figures. Start-up delay (adjustable: 1-6 sec. ) is developed in order to prevent false contact turn-off arising from initial motor start-up currents.
Un
L1 L2 L3 N
k K
I L
C1
N
CT-25
M
Un
C1
N 3~
M
3~
Type PK 25
Type PK 28
Warning leds
On Out I>Iset
:ON when power exists :ON When the output relay is switched on. :LED turns ON when current value is over adjusted level
According to Table 1
If you use AKC-03 device 2-20A interval, CT-25 current transformator must be encircled with 3 turns of the cable that current flows. At that time, I set scale takes the values below. 1,5x=2A, 3x=4A, 6x=8A, 9x=12A, 12x=16A, 15x=20A
AKC-03A / AKC-03D is only used with CT-25 current transformer. In order to reach the solution; CT-25 current transformer must be used with turn numbers in the current intervals as in the table.
Motor Current
Turn Number
Technical Data
Rated Voltage (Un) Operating Range Operating Frequency Current Adjustment Interval Current Transformer Ratio Start-up Delay Tripping Delay Output Contacts Ambient Temperature Protection Class Dimensions Installation Weight : Please look at the table on the device. : (0.9 -1.1) x Un : 50 / 60 Hz : 0.5 - 5A(AC) Please refer to table 1 for AKC-03 : .../ 5A (for AKC-01A/AKC-01D) : CT-25 (for AKC-03A/AKC-03D) : 1 - 6 sn. : 0.5 - 2.5 sn. : 1 C/O, 8A, 2000 VA, Cosj=1 : -5 0C ; +55 0C : IP 20 : Tip PK 25 : Surface mounting or on the mounting rails. : 0.3 kg
Time
Motor Current
Time
Dimensions
58 mm
16mm
WARNING: If CT-25 current transformer has more than 1 turn, isolated cable must be used. CT-25 current transformer is selling with the device.
Precautions For Installation and Safe Use
Failure to follow those instructions will result in death or serious injury. Disconnect all power before working on equipment. When the device is connected to the network, do not remove the front panel. Do not try to clean the device with solvent or the like. Only clean the device with a dried cloth. Verify correct terminal connections when wiring. Electrical equipment should be serviced only by your compedent seller. Mount device to the panel No responsibility is assured by the manufacturer or any of its subsidiaries for any consequences arising out of the use of this material.
90 mm
35 mm
TYPE PK25
45 mm 62 mm
43mm
15.5mm
TYPE PK 28
2x0,35mm2 500mm
32 mm 48 mm
35 mm
CT-25
A2842/Rev.4