Anda di halaman 1dari 4

SEPTIC TANK DESIGN

DEFINITION OF TERMS
Septic Tank a water-tight receptacle which receives the discharge of a sanitary plumbing system or part thereof, designed and constructed to retain solids, digest organic matter through a period of detention and to allow the liquids to discharge into the soil outside of the tank through a system of open-jointed sub-surface pipings or a seepage pit meeting the requirements of the code. Sewage any wastewater containing animal or vegetable matter in suspension or solution and may include liquids containing chemicals in solution. Scum Material floating on the surface of the septic tank. Scum usually contains fats, oils and greases. Sludge the sinkable solids (soil, grit, bones, unconsumed food particles) settle to the bottom of the tank and form a sludge layer. Effluent the clarified wastewater leftover after the scum has floated to the top and the sludge has settled to the bottom. It flows through the septic tank outlet into the drain field. Daily sewage flow the volume in gallons of sewage and liquid wastes flowing into a septic tank during a 24 hours period. Manhole Access opening to a hole, usually with a cover, through which a person may enter a sewer. Cleanout drain pipe that provides access for the purpose of clearing an obstruction. PVC Polyvinyl Chloride. Potable water pipings are color-coded BLUE.

COMPUTATION FOR THE SIZE OF THE SEPTIC TANK

Type of Establishment: No. of Persons: Gallons per person per day: Gallons per day: Using the formula: V = 1.125 + 0.75Q where

Single family dwelling 9 75 9 x 75 = 675

V = Liquid volume of the tank in gallons Q = The daily sewage flow in gallons per day. 1.125 and 0.75 are constant values.

V = 1.125 + 0.75 (675) V = 507.375 gallons V = 507.375 gallons ( V = 1.92 m3 For the dimensions of the septic tank, the minimum depth is 1.20 meters and the width is assumed to be 1.0 meter: Length of the digestion chamber: L= Total Length: +L= + 1.6 = 2.40 meters

= 1.60 meters

References: Revised National Plumbing Code of the Philippines, Chapter 2 Plumbing Design & Estimate by Max Fajardo, Jr., pp. 92-96 http://www.standardplumbing.com

Anda mungkin juga menyukai