Anda di halaman 1dari 26

1

10

11

12

13

14

15

16

17

PROJECT TEAM
ARCHITECT
Baker Barrios Architects 189 S. Orange Avenue, Suite 1700 Orlando, FL 32801 Tel: (407) 926-3000 Fax: (407) 926-3390

CIVIL ENGINEER
ARCADIS US 1650 Prudential Drive Jacksonville, FL 32208 Tel: (904) 721-2991 Fax: (904) 861-2450

LANDSCAPE
Baker Barrios Architects 189 S. Orange Avenue, Suite 1700 Orlando, FL 32801 Tel: (407) 926-3000 Fax: (407) 926-3390

STRUCTURAL ENGINEER
M M

R.L. Plowfield & Associates 1073 Willa Springs Dr #2061 Winter Springs, FL 32708 Tel: (407) 657-6657 Fax: (407) 657-8480

MEP ENGINEER

UNIVERSITY OF NORTH FLORIDA


OSPREY CLUBHOUSE

Sims Wilkerson Cartier Engineering 12124 High Teck Ave, Suite 200 Orlando, FL 32817 Tel: (407) 380-0400 Fax: (407) 380-5900

POOL EQUIPMENT
Aquatic Design Engineering 189 S. Orange Avenue, Suite 1250 Orlando, FL 32801 Tel: (407) 656-8002 Fax: (407) 656-1105

KITCHEN EQUIPMENT
K

JRA Food Service Consultants, LLC 401 Hall Street SW, Suite 234 Grand Rapids, MI 49503 Tel: (616) 454-4433 Fax: (616) 454-7199

UNF DRIVE JACKSONVILLE, FL

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

ISSUE FOR PERMIT


APRIL 15, 2013

UNF OSPREY CLUBHOUSE


UNF DRIVE

COVER SHEET
A A

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G0.000

10

11

12

13

14

15

16

17

GENERAL NOTES
DWG. NO.
G0.000 G0.001 G0.100 G1.100 G1.101 G1.200 G1.201 G2.101 G2.102 G2.103 LANDSCAPE L200 L210 L300 L320 L330 L331 L620 L630 L631 L700 L710 L720 L730 L800 L810 L820 POOL W0.002 W0.010 W0.011 W0.012 W0.013 W0.100 W0.200 W0.300 W0.310 W0.320 W1.000 W1.010 W1.011 W1.100 W1.110 W1.120 W1.130 W1.200 W1.210 W1.211 W1.220 STRUCTURE S1.101 S1.102 S1.103 S1.104 S1.111 S1.112 S2.101 S2.102 S2.103 S3.101 S3.102 S3.103 S3.104 S4.101 S4.102 ARCHITECTURE A0.101 A0.102 A0.103 A1.101 A1.102 A1.103 A1.104 A1.301 A2.101 A2.102 A2.201 A2.301 A2.302 A2.401 A2.402 INDEX & LEGENDS NOTES & SPECIFICATIONS NOTES & SPECIFICATIONS NOTES & SPECIFICATIONS NOTES & SPECIFICATIONS PARTIAL SITE PLAN EQUIPMENT YARD DIMENSIONS & UTILITY CONNECTIONS DETAILS DETAILS DETAILS POOL BOM & ID EQUIPMENT YARD BOM EQUIPMENT YARD - FILTRATION EQUIPMENT ID POOL DIMENSIONS POOL BONDING POOL PIPING PIPING DIAGRAM POOL SECTIONS POOL DETAILS POOL DETAILS & FINISHES POOL FILTRATION ASSEMBLY DETAILS 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

REV
GENERAL
P

DRAWING TITLE
COVER SHEET INDEX OF DRAWINGS GENERAL NOTES CODE ANALYSIS LIFE SAFETY AND EGRESS PLANS PARTITION TYPES UL DETAILS DOOR SCHEDULES - DOOR & FRAME TYPES DOOR DETAILS DOOR DETAILS

REV DATE HISTORY


04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

REV

DWG. NO.
A3.101 A3.102 A4.101 A4.102 A4.103 A4.104 A4.201 A4.301 A4.302 A4.303 A5.101 A5.102 A6.101 A6.110 A6.111 A6.201 A6.202 A7.001 A7.101 A7.102 A7.201 A7.301 A7.302 A7.401 A7.402 A7.501 A8.101 A8.102 A8.201

DRAWING TITLE
BUILDING SECTIONS BUILDING SECTIONS WALL SECTIONS WALL SECTIONS WALL SECTIONS WALL SECTIONS SECTION DETAILS ROOF DETAILS ROOF DETAILS CANOPY DETAILS RESTROOM PLANS, CEILING PLANS AND MOUNTING HEIGHTS RESTROOM ELEVATIONS STAIR PLANS AND SECTIONS STAIR DETAILS STAIR DETAILS & ROOF ACCESS LADDER ELEVATOR PLANS, SECTIONS & DETAILS ELEVATOR CAB DETAILS FINISH LEGENDS & SCHEDULES FIRST FLOOR FINISH PLAN SECOND FLOOR FINISH PLAN INTERIOR ELEVATIONS LOBBY DESK PLAN AND DETAILS CASEWORK PLANS, ELEVATIONS AND DETAILS FIRST FLOOR FURNITURE PLAN (REFERENCE ONLY) SECOND FLOOR FURNITURE PLAN (REFERENCE ONLY) FINISH DETAILS FIRST FLOOR CEILING PLAN SECOND FLOOR CEILING PLAN CEILING DETAILS

REV DATE HISTORY


04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13
P

1. SEE EARLY SITE PACKAGE DATED 3/14/13 FOR CIVIL DOCUMENTS.

SITE GRADING NOTES SITE GRADING PLAN SITE LAYOUT AND HARDSCAPE NOTES SITE HARDSCAPE PLAN HARDSCAPE DETAILS HARDSCAPE DETAILS SITE FURNISHING PLAN SITE FURNISHING DETAILS SITE FURNISHINGS DETAILS LANDSCAPE NOTES & SCHEDULES LANDSCAPE TREE PLAN LANDSCAPE SCRUB PLAN LANDSCAPE PLANTING DETAILS IRRIGATION NOTES AND SCHEDULES IRRIGATION PLAN IRRIGATION DETAILS

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

MECHANICAL M0.100 M1.101 M1.102 M2.101 M3.101 M4.100 M5.100 PLUMBING P0.100 P1.101 P1.102 P3.100 P3.101 P4.100 P4.101 FIRE PROTECTION FP0.100 FP1.100A FP1.100B FP1.101 FP1.102 ELECTRICAL E0.100 E0.101 E1.100C E1.100D E1.101 E1.102 E1.104 E2.101 E2.102 E2.103 E3.101 E4.101 E4.102 E4.103 E5.101 E5.102 E5.103 E5.104 TECHNOLOGY T1.101 T1.102 KITCHEN K1.101 K1.102 K1.103 K1.104 K1.105 K1.106

LEGEND AND GENERAL NOTES - MECHANICAL FIRST FLOOR PLAN - MECHANICAL SECOND FLOOR PLAN - MECHANICAL ENLARGED PLANS - MECHANICAL CONTROL SCHEMATICS - MECHANICAL SCHEDULES - MECHANICAL DETAILS - MECHANICAL

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

LEGEND NOTES AND SCHEDULES - PLUMBING FIRST FLOOR PLAN - PLUMBING SECOND FLOOR PLAN - PLUMBING ENLARGED PLANS - PLUMBING ENLARGED PLAN - PLUMBING RISER DIAGRAMS - PLUMBING RISER DIAGRAMS - PLUMBING

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

LEGEND NOTES AND SCHEDULES - FIRE PROTECTION SITE DEMOLITION PLAN - FIRE PROTECTION SITE RENOVATION PLAN - FIRE PROTECTION FIRST FLOOR PLAN - FIRE PROTECTION SECOND FLOOR PLAN - FIRE PROTECTION

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

GENERAL STRUCTURAL NOTES STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SCHEDULES STRUCTURAL SECTIONS & DETAILS FIRST FLOOR PLAN SECOND FLOOR FRAMING PLAN ROOF FRAMING PLAN STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL DETAILS & SCHEDULES

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

ARCHITECTURAL SITE PLAN SERVICE YARD PLAN & DETAILS MAIL BOX DETAILS FIRST FLOOR PLAN SECOND FLOOR PLAN CLERESTORY PLAN ROOF PLAN PLAN DETAILS EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS ELEVATION DETAILS GLAZING ELEVATIONS LOUVER ELEVATIONS & DETAILS GLAZING DETAILS GLAZING DETAILS

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

SYMBOL LEGEND - ELECTRICAL LIGHT FIXTURE SCHEDULE AND GENERAL NOTES - ELECTRICAL SITE DEMO PLAN - POWER, SYSTEMS AND LIGHTING SITE RENOVATION PLAN - POWER, SYSTEMS AND LIGHTING FIRST FLOOR PLAN - POWER AND FIRE ALARM SECOND FLOOR PLAN - POWER AND FIRE ALARM ROOF PLAN - ELECTRICAL FIRST FLOOR PLAN - LIGHTING SECOND FLOOR PLAN - LIGHTING ENLARGED KITCHEN PLAN - ELECTRICAL RISER DIAGRAMS - ELECTRICAL SCHEDULES - ELECTRICAL PANEL SCHEDULES - ELECTRICAL PANEL SCHEDULES - ELECTRICAL DETAILS - ELECTRICAL DETAILS - ELECTRICAL DETAILS - ELECTRICAL DETAILS - ELECTRICAL

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

FIRST FLOOR PLAN - TECHNOLOGY SECOND FLOOR PLAN - TECHNOLOGY

04/15/13 04/15/13

FOOD FOOD FOOD FOOD FOOD FOOD

SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE

EQUIPMENT FLOOR PLAN FABRICATION DETAILS ELECTRICAL FLOOR PLAN PLUMBING FLOOR PLAN REFRIGERATION FLOOR PLAN VENTILATION FLOOR PLAN

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

UNF OSPREY CLUBHOUSE


UNF DRIVE

INDEX OF DRAWINGS
A A

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G0.001

10

11

12

13

14

15

16

17

GENERAL NOTES
DWG. NO.
G0.000 G0.001 G0.100 G1.100 G1.101 G1.200 G1.201 G2.101 G2.102 G2.103 LANDSCAPE L200 L210 L300 L320 L330 L331 L620 L630 L631 L700 L710 L720 L730 L800 L810 L820 POOL W0.002 W0.010 W0.011 W0.012 W0.013 W0.100 W0.200 W0.300 W0.310 W0.320 W1.000 W1.010 W1.011 W1.100 W1.110 W1.120 W1.130 W1.200 W1.210 W1.211 W1.220 STRUCTURE S1.101 S1.102 S1.103 S1.104 S1.111 S1.112 S2.101 S2.102 S2.103 S3.101 S3.102 S3.103 S3.104 S4.101 S4.102 ARCHITECTURE A0.101 A0.102 A0.103 A1.101 A1.102 A1.103 A1.104 A1.301 A2.101 A2.102 A2.201 A2.301 A2.302 A2.401 A2.402 INDEX & LEGENDS NOTES & SPECIFICATIONS NOTES & SPECIFICATIONS NOTES & SPECIFICATIONS NOTES & SPECIFICATIONS PARTIAL SITE PLAN EQUIPMENT YARD DIMENSIONS & UTILITY CONNECTIONS DETAILS DETAILS DETAILS POOL BOM & ID EQUIPMENT YARD BOM EQUIPMENT YARD - FILTRATION EQUIPMENT ID POOL DIMENSIONS POOL BONDING POOL PIPING PIPING DIAGRAM POOL SECTIONS POOL DETAILS POOL DETAILS & FINISHES POOL FILTRATION ASSEMBLY DETAILS 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

REV
GENERAL
P

DRAWING TITLE
COVER SHEET INDEX OF DRAWINGS GENERAL NOTES CODE ANALYSIS LIFE SAFETY AND EGRESS PLANS PARTITION TYPES UL DETAILS DOOR SCHEDULES - DOOR & FRAME TYPES DOOR DETAILS DOOR DETAILS

REV DATE HISTORY


04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

REV

DWG. NO.
A3.101 A3.102 A4.101 A4.102 A4.103 A4.104 A4.201 A4.301 A4.302 A4.303 A5.101 A5.102 A6.101 A6.110 A6.111 A6.201 A6.202 A7.001 A7.101 A7.102 A7.201 A7.301 A7.302 A7.401 A7.402 A7.501 A8.101 A8.102 A8.201

DRAWING TITLE
BUILDING SECTIONS BUILDING SECTIONS WALL SECTIONS WALL SECTIONS WALL SECTIONS WALL SECTIONS SECTION DETAILS ROOF DETAILS ROOF DETAILS CANOPY DETAILS RESTROOM PLANS, CEILING PLANS AND MOUNTING HEIGHTS RESTROOM ELEVATIONS STAIR PLANS AND SECTIONS STAIR DETAILS STAIR DETAILS & ROOF ACCESS LADDER ELEVATOR PLANS, SECTIONS & DETAILS ELEVATOR CAB DETAILS FINISH LEGENDS & SCHEDULES FIRST FLOOR FINISH PLAN SECOND FLOOR FINISH PLAN INTERIOR ELEVATIONS LOBBY DESK PLAN AND DETAILS CASEWORK PLANS, ELEVATIONS AND DETAILS FIRST FLOOR FURNITURE PLAN (REFERENCE ONLY) SECOND FLOOR FURNITURE PLAN (REFERENCE ONLY) FINISH DETAILS FIRST FLOOR CEILING PLAN SECOND FLOOR CEILING PLAN CEILING DETAILS

REV DATE HISTORY


04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13
P

1. SEE EARLY SITE PACKAGE DATED 3/14/13 FOR CIVIL DOCUMENTS.

SITE GRADING NOTES SITE GRADING PLAN SITE LAYOUT AND HARDSCAPE NOTES SITE HARDSCAPE PLAN HARDSCAPE DETAILS HARDSCAPE DETAILS SITE FURNISHING PLAN SITE FURNISHING DETAILS SITE FURNISHINGS DETAILS LANDSCAPE NOTES & SCHEDULES LANDSCAPE TREE PLAN LANDSCAPE SCRUB PLAN LANDSCAPE PLANTING DETAILS IRRIGATION NOTES AND SCHEDULES IRRIGATION PLAN IRRIGATION DETAILS

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

MECHANICAL M0.100 M1.101 M1.102 M2.101 M3.101 M4.100 M5.100 PLUMBING P0.100 P1.101 P1.102 P3.100 P3.101 P4.100 P4.101 FIRE PROTECTION FP0.100 FP1.100A FP1.100B FP1.101 FP1.102 ELECTRICAL E0.100 E0.101 E1.100C E1.100D E1.101 E1.102 E1.104 E2.101 E2.102 E2.103 E3.101 E4.101 E4.102 E4.103 E5.101 E5.102 E5.103 E5.104 TECHNOLOGY T1.101 T1.102 KITCHEN K1.101 K1.102 K1.103 K1.104 K1.105 K1.106

LEGEND AND GENERAL NOTES - MECHANICAL FIRST FLOOR PLAN - MECHANICAL SECOND FLOOR PLAN - MECHANICAL ENLARGED PLANS - MECHANICAL CONTROL SCHEMATICS - MECHANICAL SCHEDULES - MECHANICAL DETAILS - MECHANICAL

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

LEGEND NOTES AND SCHEDULES - PLUMBING FIRST FLOOR PLAN - PLUMBING SECOND FLOOR PLAN - PLUMBING ENLARGED PLANS - PLUMBING ENLARGED PLAN - PLUMBING RISER DIAGRAMS - PLUMBING RISER DIAGRAMS - PLUMBING

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

LEGEND NOTES AND SCHEDULES - FIRE PROTECTION SITE DEMOLITION PLAN - FIRE PROTECTION SITE RENOVATION PLAN - FIRE PROTECTION FIRST FLOOR PLAN - FIRE PROTECTION SECOND FLOOR PLAN - FIRE PROTECTION

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

GENERAL STRUCTURAL NOTES STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SCHEDULES STRUCTURAL SECTIONS & DETAILS FIRST FLOOR PLAN SECOND FLOOR FRAMING PLAN ROOF FRAMING PLAN STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL SECTIONS & DETAILS STRUCTURAL DETAILS & SCHEDULES

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

ARCHITECTURAL SITE PLAN SERVICE YARD PLAN & DETAILS MAIL BOX DETAILS FIRST FLOOR PLAN SECOND FLOOR PLAN CLERESTORY PLAN ROOF PLAN PLAN DETAILS EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS ELEVATION DETAILS GLAZING ELEVATIONS LOUVER ELEVATIONS & DETAILS GLAZING DETAILS GLAZING DETAILS

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

SYMBOL LEGEND - ELECTRICAL LIGHT FIXTURE SCHEDULE AND GENERAL NOTES - ELECTRICAL SITE DEMO PLAN - POWER, SYSTEMS AND LIGHTING SITE RENOVATION PLAN - POWER, SYSTEMS AND LIGHTING FIRST FLOOR PLAN - POWER AND FIRE ALARM SECOND FLOOR PLAN - POWER AND FIRE ALARM ROOF PLAN - ELECTRICAL FIRST FLOOR PLAN - LIGHTING SECOND FLOOR PLAN - LIGHTING ENLARGED KITCHEN PLAN - ELECTRICAL RISER DIAGRAMS - ELECTRICAL SCHEDULES - ELECTRICAL PANEL SCHEDULES - ELECTRICAL PANEL SCHEDULES - ELECTRICAL DETAILS - ELECTRICAL DETAILS - ELECTRICAL DETAILS - ELECTRICAL DETAILS - ELECTRICAL

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

FIRST FLOOR PLAN - TECHNOLOGY SECOND FLOOR PLAN - TECHNOLOGY

04/15/13 04/15/13

FOOD FOOD FOOD FOOD FOOD FOOD

SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE

EQUIPMENT FLOOR PLAN FABRICATION DETAILS ELECTRICAL FLOOR PLAN PLUMBING FLOOR PLAN REFRIGERATION FLOOR PLAN VENTILATION FLOOR PLAN

04/15/13 04/15/13 04/15/13 04/15/13 04/15/13 04/15/13

UNF OSPREY CLUBHOUSE


UNF DRIVE

INDEX OF DRAWINGS
A A

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G0.001

10

11

12

13

14

15

16

17

DRAWING ABBREVIATIONS

SYMBOL LEGEND
DETAIL NUMBER NUMBER 001

MATERIALS LEGEND

GENERAL NOTES
1. THESE DOCUMENTS HAVE BEEN PREPARED TO THE BEST OF OUR ABILITY TO BE IN COMPLIANCE AND CONFORMANCE WITH THE FEDERAL ACCESSIBILITY LAW CONTAINED WITHIN THE AMERICANS WITH DISABILITIES ACT GUIDELINES (ADAAG) FOR DESIGN. 2. THE DESIGN AND DRAWINGS OF THIS PROJECT HAVE BEEN SPECIFICALLY PREPARED FOR THE USE AND CONSTRUCTION AT THE LOCATION SHOWN. REPRODUCTION FOR USE IN ANY OTHER SITE OR MANNER EXCEEDS THE INTENDED PURPOSE OF THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS AND IS PROHIBITED.
WOOD FRAMING

A
P
AC OR A/C A/E AFF AHU ALT ALUM APPROX ARCH ACOUS PNL AIR CONDITIONING ARCHITECT / ENGINEER ABOVE FINISHED FLOOR AIR HANDLING UNIT ALTERNATE ALUMINUM APPROXIMATE ARCHITECT, ARCHITECTURE, ARCHITECTURAL ACOUSTICAL PANEL

N
N NA NIC NO NRC NTS NORTH NOT APPLICABLE NOT IN CONTRACT NUMBER NOISE REDUCTION COEFFICIENT NOT TO SCALE

SHEET NUMBER WHERE DETAIL IS DRAWN A1


A4.001

DOOR TAG
NUMBER FOR LOUVER A WALL/ BUILDING SECTION NUMBER LETTER FOR WINDOW
EARTH

MATERIALS

DETAIL

O
OA OC OD OVER ALL ON CENTER OUTSIDE DIAMETER / OUTSIDE DIMENSION OFFICE OPENING OPPOSITE HAND OPPOSITE ORIGINAL OVERHEAD

WINDOW / LOUVER TAG


A1
A4.002

SAND / MORTAR PLASTER

WOOD BLOCKING

SITE SURVEY DISCLAIMER: ANY SURVEY IF PROVIDED HEREIN WAS PERFORMED BY A PROPERLY REGISTERED/LICENSED SURVEYOR, AND IS INCLUDED AS PART OF THESE DOCUMENTS FOR GENERAL INFORMATION TO CONCERNED AND INVOLVED PARTIES. THE ARCHITECT DOES NOT ACCEPT RESPONSIBILITY OR LIABILITIES FOR ERRORS, OMISSIONS, AND OVERSIGHTS CONTAINED WITHIN SUCH SURVEY. 3. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES BELOW GRADE AND RELATED SERVICE CONNECTION WITH THE RESPECTIVE UTILITY COMPANIES. 4. CONTRACTOR SHALL COORDINATE THE REMOVAL, ABANDONMENT, OR RELOCATION OF EXISTING UTILITIES SHOWN ON CONSULTANTS WORK WITH THE RESPECTIVE UTILITY COMPANIES. 5. CONTRACTOR SHALL PERFORM ALL WORK WITHIN PUBLIC RIGHTS OF WAY ACCORDING TO THE PLANS AND SPECIFICATIONS AND REQUIREMENTS BY THE CITY OR GOVERNING AUTHORITY, AND SHALL OBTAIN PERMITS FROM THE APPROPRIATE AGENCIES. 6. WHEN IT IS NECESSARY TO INTERRUPT ANY EXISTING UTILITY SERVICE TO MAKE CORRECTIONS AND/OR A CONNECTION, A MINIMUM OF 48 HOURS ADVANCED NOTICE SHALL BE GIVEN TO THE OWNER. INTERRUPTIONS IN UTILITY SERVICES SHALL BE OF THE SHORTEST POSSIBLE DURATION FOR THE WORK REQUIRED AND SHALL BE APPROVED IN ADVANCED BY THE OWNER AND UTILITY COMPANY. DAMAGES REQUIREMENT: IN THE EVENT A UTILITY IS INTERRUPTED WITHOUT THE REQUIRED 48 HOURS NOTICE, THEN THE CONTRACTOR SHALL BE FINANCIALLY LIABLE FOR ALL DAMAGES SUFFERED BY THE OWNER DUE TO THE UNAUTHORIZED INTERRUPTION. RECONNECTION SHALL BE MADE IMMEDIATELY. 7. CONSTRUCTION ACCESS PARKING, OFFICES AND EXTENT/SIZE OF STAGING AREA(S) SHALL BE COORDINATED WITH THE OWNER'S SITE PERSONNEL. 8. CONTRACTOR SHALL VERIFY ALL COLUMN COORDINATES AND CHECK THEM AGAINST THE DIMENSIONS SHOWN ON THE PLANS AND DETAILS. NOTIFY ARCHITECT OF ANY DISCREPANCIES DISCOVERED DURING STAKING THE BUILDING LAYOUT.
M

B
BLDG BLK BLKG BOT BUR BUILDING BLOCK BLOCKING BOTTOM BUILT-UP ROOF

OFF OPNG OPH OPP ORIG OVHD

CEILING TYPE SHEET NUMBER WHERE DETAIL IS DRAWN A 8' - 0" CEILING HEIGHT

CONCRETE/ PRECAST CONCRETE

PLYWOOD

BRICK / VENEER

ACOUSTIC TILE / BOARD

SECTION
A1 DETAIL NUMBER SHEET NUMBER WHERE DETAIL IS DRAWN AREA TO BE DETAILED OR ENLARGED

CEILING TAG LINE 1 LINE 2


202
CMU GYPSUM BOARD

C
CC, C/C CJ CIP CJT CLG CLG HT CMU COL CONC CONT CPT CENTER TO CENTER CONSTRUCTION JOINT CAST IN PLACE CONTROL JOINT CEILING CEILING HEIGHT CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CARPET

P
PL PLAM PLAS PLYWD PNL PR PREFAB PREFIN PRELIM PREP PT PTD PLATE PLASTIC LAMINATE PLASTER PLYWOOD PANEL PAIR PREFABRICATED PREFINISHED PRELIMINARY PREPARATION PRESERVATIVE TREATED PAINTED

A2.201

METAL BATT INSULATION

ROOM NUMBER
WOOD FINISH

RIGID INSULATION

4A

DETAIL - ENLARGED PLAN


A1 A1 A1 SHEET NUMBER WHERE DETAIL IS DRAWN ELEVATION NUMBER AND KEY

WALL TYPE
1

D
DET DF DIA DIAG DIM DJ DN DR DS DWG DETAIL DRINKING FOUNTAIN DIAMETER DIAGONAL DIMENSION DEFLECTION JOINT DOWN DOOR DOWN SPOUT DRAWING

Q
QT QUARRY TILE

NOTE TAG

R
R RD REF REFL REINF REQ'D RM RO RISER OR RADIUS ROOF DRAIN REFER OR REFERENCE REFLECTED REINFORCED, REINFORCING, REINFORCEMENT REQUIRED ROOM ROUGH OPENING

A9.101

A1

E
E EA EL ELEC ELEV EQ EQUIP EWC EXIST EXP JT EXT EAST EACH ELEVATION ELECTRICAL ELEVATOR EQUAL EQUIPMENT ELECTRICAL WATER COOLER EXISTING EXPANSION JOINT EXTERIOR

INTERIOR ELEVATION NORTH ARROW


A1 ELEVATION NUMBER 1

DIMENSIONING CONVENTIONS
1. 2. DIMENSIONS ARE INDICATED ON THE DRAWINGS; DO NOT SCALE DRAWINGS FOR DIMENSIONS. DIMENSIONS SHOWN ARE TO FACE OF STUDS, MASONRY, OR CONCRETE, AND ARE INDICATED WITH A 45 SLASH MARK, UNLESS NOTED OTHERWISE AS BEING EITHER A "CLEAR", CENTERLINE, OR FINISH DIMENSION.

S
S SC SCHED SECT SHT SIM SPEC SQ SQ FT SST STA STC STD STL STRUCT SUSP SYM SYMM SOUTH SOLID CORE SCHEDULE SECTION SHEET SIMILAR SPECIFICATION SQUARE SQUARE FOOT STAINLESS STEEL STATION SOUND TRANSMISSION CLASS STANDARD STEEL STRUCTURAL SUSPENDED SYMBOL SYMMETRICAL

9. THE CONTRACTOR SHALL PROVIDE A WEATHER-RESISTANT JOB-SITE POSTING BOARD TO RECEIVE DUPLICATE TREATMENT CERTIFICATES AS EACH REQUIRED PROTECTIVE TREATMENT IS COMPLETED, PROVIDING A COPY FOR THE PERSON THE PERMIT IS ISSUED TO AND ANOTHER COPY FOR THE BUILDING PERMIT FILES. THE TREATMENT CERTIFICATE SHALL PROVIDE THE PRODUCT USED, IDENTITY OF THE APPLICATOR, TIME AND DATE OF THE TREATMENT, SITE LOCATION, AREA TREATED, CHEMICAL USED, PERCENT CONCENTRATION AND NUMBER OF GALLONS USED, TO ESTABLISH A VERIFIABLE RECORD OF PROTECTIVE TREATMENT. IF THE SOIL CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED, FINAL EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL. 10. THE GENERAL CONTRACTOR SHALL SUBMIT TO THE UNIVERSITY FOR APPROVAL STEEL FRAMING ENGINEERING SHOP DRAWINGS. SUBMITTAL SHALL BE SIGNED AND SEALED BY A LICENSED PROFESSIONAL STRUCTURAL ENGINEER IN THE STATE OF FLORIDA. 11. THE CONTRACTOR SHALL SUBMIT TO THE UNIVERSITY DATA SHEETS VERIFYING THAT ALL FOAM PLASTIC INSULATION, EXTERIOR COATINGS, AND FACING HAVE A FLAME SPREAD INDEX OF 25 OR LESS AND A SMOKE-DEVELOPED INDEX OF 450 OR LESS AS DETERMINED IN ACCORDANCE WITH ASTM E 84. 12. REFER TO THE PROJECT MANUAL (SPECIFICATIONS) FOR DETAILED MATERIAL DESCRIPTIONS AND WORKMANSHIP STANDARDS. 13. CONTRACTOR SHALL VERIFY AND COORDINATE ALL NEW AND EXISTING CONDITIONS AND DIMENSIONS AT THE JOB SITE FOR COMPARISON WITH THE DRAWINGS AND SPECIFICATIONS PRIOR TO BIDDING, START OF, AND DURING CONSTRUCTION. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES, INCONSISTENCIES OR OMISSIONS FOUND DURING BIDDING, OR UPON DISCOVERY FOR CLARIFICATION BEFORE COMMENCEMENT OR RESUMPTION OF WORK. 14. THE SPECIFICATIONS AND ALL CONSULTANT DRAWINGS SHALL BE CONSIDERED COMPLIMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE CONSULTANT PROVIDED INFORMATION WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF ANY CONSULTANTS' WORK, AND TO BRING ANY DISCREPANCIES OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT IN WRITING FOR CLARIFICATION BEFORE COMMENCEMENT OR RESUMPTION OF WORK. 15. PIPE SLEEVES, FRAMED OPENINGS AND ANY MISCELLANEOUS OPENINGS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS, WHICH ARE REQUIRED BY THE CONSULTANT WORK SHALL BE SIZED AND INSTALLED AS DETAILED ON THE APPLICABLE STRUCTURAL, MECHANICAL, FIRE PROTECTION AND ELECTRICAL DRAWINGS. CONTRACTOR SHALL COORDINATE THE FINAL PLACEMENT LOCATIONS OF SUCH OPENINGS WITH THE ARCHITECT PRIOR TO THEIR INSTALLATION. 16. CONTRACTOR SHALL RELY ON WRITTEN DIMENSIONS AS GIVEN AND SHALL FIELD VERIFY ALL DIMENSIONS PROVIDED IN THE COMPLETE DRAWING SET AND COORDINATE WITH ALL THE WORK BY ALL TRADES. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING FOR CLARIFICATIONS OF CONFLICTS DISCOVERED WITHIN THE ARCHITECTURAL DRAWINGS OR BETWEEN THE ARCHITECTURAL DRAWINGS AND ANY OTHER CONSULTANT'S DRAWINGS BEFORE COMMENCEMENT OR RESUMPTION OF WORK. 17. THE CURTAINWALL SYSTEM AS INDICATED IN THIS DRAWING SET PROVIDES THE GENERAL DESIGN INTENT OF THE CURTAINWALL SYSTEM. IT'S DEFINITION AS A "SYSTEM" WITHIN THE CONTEXT OF THIS DRAWING SET SHALL INCLUDE ALL PARTS AND ASSEMBLIES TO FULLY INSTALL THE SYSTEM INCLUDING, BUT NOT LIMITED TO, CONNECTIONS, BRACING AND INTERMEDIATE OR SECONDARY SUPPORT STEEL OR STRUCTURE NECESSARY. THE SYSTEM SHALL BE ENGINEERED AND PROVIDED IN ITS ENTIRETY BY THE CURTAINWALL MANUFACTURER. CALCULATIONS AND SHOP DRAWINGS BEARING THE SEAL OF A FLORIDA PROFESSIONAL ENGINEER MEETING ALL STATE AND LOCAL CODE REQUIREMENTS SHALL BE PROVIDED BY THE CURTAINWALL MANUFACTURER. 18. ATTACHMENTS FOR ALL EXTERIOR MATERIALS AND MATERIAL ASSEMBLIES SHALL BE MADE WITH STAINLESS STEEL FASTENERS AND SHALL BE APPROPRIATELY SIZED AND DESIGNED TO MEET REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE FOR THE WIND AREAS SPECIFIED (JACKSONVILLE UNF - 130 MPH). 19. WHERE STUDS ARE INSTALLED DIRECTLY AGAINST AN EXTERIOR MASONRY WALL OR DISSIMILAR METALS AT EXTERIOR WALLS, INSTALL ISOLATION STRIPS BETWEEN STUDS AND THE EXTERIOR WALL. 20. ALL FLOOR PENETRATIONS SHALL BE LOCATED WITHIN THE CAVITY OF A WALL TO MEET THE EXCEPTION FOR NO T-RATING. ALL PIPES AND CHUTES SHALL BE ADJUSTED AS NECESSARY TO MEET THIS REQUIREMENT OF MAINTAINING THE FLOOR PENETRATION WITHIN THE WALL OR CHASE CAVITY SPACE. 21. REFER TO STRUCTURAL DRAWINGS FOR ALL REINFORCEMENT.

A3.001 SHEET NUMBER WHERE DETAIL IS DRAWN

F
FD FDC FDV FEC FHC FIN FIN FL FIN GR FLR FLUOR FOC FOM FOS FPRF FT FTG FWC FLOOR DRAIN FIRE DEPARTMENT CONNECTION FIRE DEPARTMENT VALVE FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FINISH FINISH FLOOR FINISH GRADE FLOOR FLUORESCENT FACE OF CONCRETE FACE OF MASONRY FACE OF STUD FIREPROOFING FOOT, FEET FOOTING FABRIC WALL COVERING

EXTERIOR ELEVATION

REVISION
3. CLEAR DIMENSIONS OR DIMENSIONS TO FINISH SURFACES ARE SHOWN USING ARROW HEADS. CLEAR DIMENSIONS BETWEEN TWO FINISHED SURFACES ARE ALSO MARKED BY THE WORDS CLEAR OR "HOLD" BENEATH THE DIMENSION STRING LINE. WHERE "CLEAR" IS INDICATED; CONTRACTOR SHALL ADD FOR THICKNESS OF FINISHED GIVEN IN WALL TYPES TO LOCATE THE STUD OR FACE OF MASONRY. X

T
T T&G TEL TF TFF THK TJ TS TSL TST TW TYP TREAD TOUNG AND GROOVE TELEPHONE TOP OF FOOTING TOP OF FINISH FLOOR THICK TOP OF JOINT TUBE STEEL TOP OF SLAB TOP OF STEEL TOP OF WALL TYPICAL

4.

DIMENSIONS TO CENTERLINES OF WALLS OR PARTITIONS ARE DRAWN USING DOTS, AS SHOWN.

G
GA GALV GL GR GYP GYP BD GYP PLAS GAUGE GALVANIZED GLASS GRADE GYPSUM GYPSUM BOARD GYPSUM PLASTER

5. WALLS OR PARTITIONS THAT ARE SHOWN ON CENTERLINES OF GRIDS, COLUMNS, OR MULLIONS ARE NOT DIMENSIONED AND ARE DRAWN AS SHOWN.

U
UNFIN UON UPS UNFINISHED UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY

X 6. WALLS OR PARTITIONS THAT ARE SHOWN WITH ONE FACE ALIGNED WITH A GRID OR COLUMN CENTERLINE ARE NOT DIMENSIONED AND ARE DRAWN TO INDICATE THE FINISH FACE OF THE WALL.

H
HC HGT HM HMD HMF HVAC HOLLOW CORE HEIGHT HOLLOW METAL HOLLOW METAL DOOR HOLLOW METAL FRAME HEATING, VENTILATION, AIR CONDITIONING

V
VCT VERT VWC VINYL COMPOSITION TILE OR VITRIFIED CLAYTILE VERTICAL VINYL WALL COVERING

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

I
ID INSUL INTR INSIDE DIAMETER INSULATION INTERIOR

W
W W/ W/O WC WD WDW WF WI WP WWF WEST WITH WITHOUT WATER CLOSET WOOD OR WIDTH WINDOW WIDE FLANGE WROUGHT IRON WORK POINT WELDED WIRE FABRIC

7. WALLS OR PARTITIONS THAT ARE SHOWN WITH ONE FACE ALIGNED WITH ANOTHER WALL OR COLUMN PARALLEL AND IN THE SAME PLAIN ARE NOT DIMENSIONED AND ARE LOCATED WITH AN ALIGNMENT TAG AS A SHOWN.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

J
JAN JST JT JANITOR JOIST JOINT

8.

ELEMENTS POSITIONED CENTERED WITHIN A SPACE ARE LOCATED BY THE TERM "EQUAL" AS SHOWN. DIM - X MUST BE SHOWN.

L
LAV LT WT LAVATORY LIGHT WEIGHT

EQ.

EQ.

M
F
MAINT MAS MAX MECH MEZZ MFG MFR MIN MISC MO MULL MAINTENANCE MASONRY MAXIMUM MECHANICAL MEZZANINE MANUFACTURING MANUFACTURER MINIMUM MISCELLANEOUS MASONRY OPENING MULLION

9. LOCATING DOORS: A. TYPICAL: DOOR JAMBS IN STUD WALLS LOCATED ADJACENT AND PERPENDICAULAR TO WALLS ARE NOT DIMENSIONED, AND SHALL OCCUR 6" FROM WALL TO FRONT OF JAMB UNLESS SHOWN OTHERWISE BY A DETAIL REFERENCE. B. OTHERWISE BY DIMENSION TO BACK OF JAMB. OR CENTER LINE OF DOOR.

22. THE CONTRACTOR SHALL COORDINATE THE PRECISE SIZES AND LOCATIONS OF ANY EQUIPMENT PADS REQUIRED BASED ON THE ACTUAL EQUIPMENT PROVIDED. 23. ROUGH OPENING (RO) AND MASONRY OPENING (M0) DIMENSIONS ARE NOMINAL AND / OR MODULAR. DIMENSIONS MAY VARY DEPENDING ON THE TYPE OF BUILDING ELEMENT AND THE DETAILS PROVIDED.

6" TYP.
E

C. TYPICAL: DOOR JAMBS IN MASONRY WALLS LOCATED ADJACENT AND PERPENDICULAR TO OTHER MASONRY WALLS ARE NOT DIMENSIONED, AND SHALL OCCUR 8" FROM WALL UNLESS SHOWN OTHERWISE BY A DETAIL REFERENCE.

8" TYP. 10. A. B. LOCATING OPENINGS: ROUGH OPENING. MASONRY OPENING.

X MO

X RO

X MO

UNF OSPREY CLUBHOUSE


UNF DRIVE

GENERAL NOTES
A A

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G0.100

10

11

12

13

14

15

16

17

BUILDING CODE SUMMARY


I.
N

PROJECT INFORMATION PROJECT NAME: LOCATION: AHJ: UNIVERSITY OF NORTH FLORIDA OSPREY CLUBHOUSE & POOL FACILITY JACKSONVILLE, FLORIDA UNIVERSITY OF NORTH FLORIDA

IV.

FIRE RATED CONSTRUCTION REQUIREMENTS (cont'd) B. WALL OPENINGS 1. MAXIMUM SIZE DISTANCE 0'-3' UP, NS NP NP 10% 15% 25% 45% 70% NL UP, S NP 15% 25% 45% 75% NL NL NOT REQUIRED Table 705.8 P NP 15% 25% 45% 75% NL NL NOT REQUIRED

VIII.

MISCELLANEOUS REQUIREMENTS A. MINIMUM PLUMBING FACILITIES (POOL) TABLE 403.6 3000 S.F. POOL PLUS UP TO 9,000 S.F. DECK AREA 1. WATER CLOSETS MALE FEMALE 2. URINALS MALE 3. LAVATORIES MALE FEMALE 1 1 3 3
M N

REQUIRED

PROVIDED

1 5

1 5

OWNER:

UNIVERSITY OF NORTH FLORIDA

>3'-5' >5'-10'

APPLICABLE CODES
BUILDING:
M

>10'-15' 2010 FLORIDA BUILDING CODE 2010 FLORIDA MECHANICAL CODE 2010 FLORIDA PLUMBING CODE 2010 FLORIDA ELECTRICAL CODE & 2008 NATIONAL ELECTRICAL CODE 2010 FLORIDA FUEL GAS CODE 2010 FLORIDA FIRE CODE & NFPA 101 2. >15'-20' >20'-25' >25'-30' >30'
UP = unprotected, S = sprinklered, NS = non-sprinklered P = protected

MECHANICAL: PLUMBING: ELECTRICAL: FUEL GAS: FIRE:

B. Table 715.4

MINIMUM PLUMBING FACILITIES (BUILDING) 1. WATER CLOSETS A-2 MALE (1 per 75) FEMALE (1 per 75) OCCUPANTS 368 184 184 3 3 3* 3*
L

RATINGS TYPE OF ASSEMBLY ASSEMBLY RATING 1 HOUR 1 HOUR OPENING RATING 1 HOUR 45 MIN.

REQUIRED

PROVIDED

CODE CHECK BY:


L

MICHAEL HOUSEMAN MICHAEL HOUSEMAN MICHAEL HOUSEMAN

SDs: DDs: CDs:

10/02/2012 01/11/2013 03/14/2013

SHAFT, EXIT ENCLOSURE & EXIT PASSAGEWAY OTHER FIRE BARRIERS FIRE PARTITIONS: CORRIDOR WALLS

1 HOUR 1 HOUR 1 HOUR 1 HOUR

20 MIN. 45 MIN. 45 MIN. 20 MIN.

2.

LAVATORIES A-2 MALE (1 per 200) FEMALE (1 per 200)

OCCUPANTS 368 184 184

REQUIRED

PROVIDED

AREA OF PROPOSED BUILDING AREA FIRST FLOOR SECOND FLOOR 10,348 SF 4,696 SF OCCUPANCY ASSEMBLY, GROUP A-2 ASSEMBLY, GROUP A-2 C.
K

OTHER FIRE PARTITIONS EXTERIOR WALLS SMOKE BARRIERS

1 1

3* 2*

INTERIOR FINISHES SPACE REQUIRED CLASS B CLASS B/C CLASS C CLASS II

Table 803.5

*UNISEX TOILET & LAVATORY PROVIDED UPSTAIRS FOR CONVENIENCE


K

TOTAL

15,044 SF

EXIT ENCLOSURES AND EXIT PASSAGEWAYS CORRIDORS

3.

DRINKING FOUNTAINS FIRST FLOOR A-2 (1 per 500)

OCCUPANTS

REQUIRED

PROVIDED

SPRINKLED BUILDING

YES

ROOMS AND ENCLOSED SPACES INTERIOR FLOOR FINISH

368

2*

Section 804.4.1 4. OTHER SERVICE SINK REQUIRED 1 PROVIDED 1

II.

USE AND OCCUPANCY A. CLASSIFICATION PRIMARY ADDITIONAL GROUP A2 - ASSEMBLY -

CHAPTER 3 Section 302.1 304.1 303.1 B. EXTINGUISHERS: HAZARD: AREA PER EXTINGUISHER: TRAVEL DISTANCE: MODERATE 3000 SF 75 FT NFPA 10 V. FIRE PROTECTION SYSTEM REQUIREMENTS A. AUTOMATIC SPRINKLER SYSTEM PROVIDED

*ADDITIONAL HYDRATION STATION PROVIDED


J

B.

INCIDENTAL USE AREAS AREA REQUIRED PROVIDED -

Table 508.2.5

C.

STANDPIPE REQUIRED:

--

Section 905.1
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

*Provide an automatic fire-extinguishing system. Where no fire barrier is required, the incidental use area shall be sparated by construction capbable of resisting the passage of smoke. Doors shall be self-closing or automatic--closing upon detection of smoke. Doors shall not have air transfer openings and shall not be undercut in excess of the clearance permitted in accordance with NFPA 80.

D.

FIRE ALARM AND DETECTION SYSTEMS:

PROVIDED

Section 907.2.1/907.2.2
H

VI. C. ACCESSORY USE AREAS: BUSINESS & STORAGE Section 508.2

OCCUPANT LOAD FACTORS A. BUSINESS AREAS 100 GROSS

TABLE 1004.1.1

NO
D. MIXED OCCUPANCY: NON-SEPARATED Section 508.3.2 B. ASSEMBLY (A-2) UNCONCENTRATED 15 NET

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

III.
G

AREA LIMITATIONS AND CONSTRUCTION TYPES A. PROPOSED CONSTRUCTION TYPE II-B

CHAPTER 5 Table 601

C.

KITCHEN, COMMERCIAL

200 GROSS
G

D. B. ALLOWABLE HEIGHT AND BUILDING AREAS 1. 2. ALLOWABLE HEIGHT: ALLOWABLE AREA: GROUP A-2 55'/2 STORY 9,500 SF A. C. AREA AND HEIGHT MODIFICATIONS 1. 2. UNLIMITED HEIGHT: HT SPRINKLER MODIFICATION: AREA MODIFICATIONS: INCREASE DUE TO SPRINKLER: INCREASE DUE TO FRONTAGE: ALLOWED AREA MODIFICATION: 19,000 SF 4,750 33,250 SF D. D. AREA AND HEIGHT SUMMARY 1. HEIGHT ASSEMBLY (A-2) PROPOSED 39'/2 STORY C. N/A 20'/1 STORY Section 504.2 Equation 5-1 Section 506 B. Table 503 VII.

ACCESSORY (MECHANICAL, ELECTRICAL, STORAGE)

300 GROSS

MEANS OF EGRESS

GROUP A MAXIMUM

COMMON PATH OF TRAVEL:

20'

CHAPTER 10

EXIT ACCESS TRAVEL DISTANCE EXIT ACCESS TRAVEL DISTANCE WITH SPRINKLER SYSTEM

200' 250'

Section 1014
F

3.

Section 1016.1

DEAD END CORRIDOR

20'

Section 1018.4

COMMUNICATING SPACE THE SECOND MEANS OF EGRESS FROM THE SECOND FLOOR IS PROVIDED THROUGH THE LOBBY, WHICH IS A COMMUNICATING SPACE, PERMITTED BY NFPA 101, 8.6.6(4)a. THE SMOKE BARRIER VIA THE OVERHEAD COILING DOORS, SHALL BE CONNECTED TO THE FIRE ALARM WITHIN THE FULLY SPRINKLERED BUILDING.
E

2.

AREA ASSEMBLY (A-2) 15,044 SF

IV.

FIRE RATED CONSTRUCTION REQUIREMENTS A. BUILDING ELEMENTS 1. 2. 3. STRUCTURAL FRAME EXTERIOR BEARING WALL: INTERIOR BEARING WALL: EXTERIOR NON-BEARING WALLS: (0'<5' FIRE SEPARATION DISTANCE) (5'<10' FIRE SEPARATION DISTANCE) (10'<30' FIRE SEPARATION DISTANCE) (30' FIRE SEPARATION DISTANCE) 5. 6. 7. FLOOR CONSTRUCTION: ROOF CONSTRUCTION: SHAFT ENCLOSURES: MECHANICAL ROOMS: ELEVATOR EQUIP ROOMS: TENANT SEPARATION: 1 HR 1 HR 0 HR 0 HR 0 HR 0 HR 1 HR -1 HR -0 HR 0 HR 0 HR

CHAPTER 6, 7 and 8 Table 601

4.

Table 602

Section 708.4 Table 602 Section 3006.4


C

8. 9. 10.

UNF OSPREY CLUBHOUSE


UNF DRIVE

CODE ANALYSIS
A A

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G1.100

10

11

12

13

14

15

16

17

LIFE SAFETY LEGEND


SYMBOL DESCRIPTION
WALL RATING DESIGNATION 1 HOUR RATED WALL
55 0 34

OVERHEAD COLING DOORS TIED TO ALARM


32 170

ASSEMBLY 64 A OLF EXITS 955 1/15 2 UP


80 160
P

SMOKETIGHT ENCLOSURE

TRAVEL DISTANCE ## (# #) EXITING


FD

40 340
55 0 34
' 13 -6

TRAVEL DISTANCE (FEET) COMMON PATH OF TRAVEL (FEET)

" /8

GAME ROOM
1100 ASSEMBLY 110 A 1648 OLF 1/15 EXITS 2
' 43

GRILL
1400 LOBBY IS SEPARATED FROM ADJACENT SPACES BY SMOKE TIGHT WALLS COMMERCIAL KITCHEN 7

X Y
N

X = OCCUPANTS USING EXIT (PERSONS) Y = EXIT CAPACITY (PERSONS) (ARROW INDICATES DIRECTION OF TRAVEL) EMERGENCY EXIT SIGN

-6 6" /1 11

FIRE PROTECTION SYSTEMS FE FEC FAAP FIRE EXTINGUISHER (SEE DETAIL --/G1.---) FIRE ALARM ANNUNCIATOR PANEL

LOBBY
1000-9

KITCHEN
1401

A 1293 OLF 1/200 EXITS 1

OCCUPANT AND EGRESS ASSEMBLY 45 A 21054 OLF 120 EXITS 2 OCCUPANCY TYPE OCCUPANT LOAD AREA IN SF OCCUPANT LOAD FACTOR EXITS REQUIRED FROM AREA OR SPACE

FE

STORAGE
1 1111 1 1010-9

FE

MECHANICAL

DESK
1110

80 160

OFFICE A
1310

BUSIN ESS 3 BUSIN ESS 7 A 638 OLF 1/100 EXITS 1

WOMEN
1500-9

MEN
1140-9

JANITOR
1130-9 FEC FAAP

CORRIDOR
1300-9

213 OLF 1/100 EXITS 1

39 220

SERVICE YARD

22
FD

OCCUPANT LOAD BY ACTUAL COUNT

FE

RA PROJECTS
1311

50 ) (11

ELECTRICAL MECHANICAL
FD

VESTIBULE
1120-9

1040-9
L

40 170

1020-9
10 170

2 1

MEN
1510-9

WOMEN
1150-9

FAMILY
1160-9 BUSINESS 6

D/DD/DD/DD/DD/DD/DD/DD/D
K

6 170

LAUNDRY
FD

A 526 OLF 1/100 EXITS 1


FD

1200

UNDERSIDE OF STAIR ENCLOSED

1
H

FIRST FLOOR LIFE SAFETY & EGRESS PLAN


3/32" = 1'-0"
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

ANY OCCUPANTS IN THE SECOND FLOOR CORRIDOR CAN EXIT WITHOUT REENTERING THE SMOKETIGHT ENCLOSURE

ENTIRE LOBBY VISIBLE FROM SECOND FLOOR CORRIDOR


F

27 160

EXTERIOR BALCONY

27 160

80 160
F

FEC

26 160

OPEN TO BELOW CORRIDOR


E

CORRIDOR UNISEX
2220-9 ASSEMBLY 9 A OLF EXITS 135 1/15 1 110' TOTAL TO GROUND FLOOR INCLUDING STAIR
E

MDF
2210-9

2010-9

18" DRAFT STOP BELOW SECOND FLOOR AT STAIR OPENING

PREP KITCHEN
2200-9

ELEV EQUIP ELEVATOR


80 160

2201-9

MULTI-PURPOSE A
2100-A ASSEMBLY

MULTI-PURPOSE B
2100-B ASSEMBLY 73 A 1091 OLF 1/15 EXITS 2
58 (19 )

STORAGE
D

74 A 1107 OLF 1/15 EXITS 2

2120-9

FE

MECHANICAL
2110-9

UNF OSPREY CLUBHOUSE


UNF DRIVE

2
A

SECOND FLOOR LIFE SAFETY & EGRESS PLAN


3/32" = 1'-0"
A

LIFE SAFETY AND EGRESS PLANS NORTH


17 16 15 14 13 12 11 10 9 8 7

PROJECT NO:

120063.00
6 5 4 3 2 1

G1.101

10

11

12

13

14

15

16

17

GENERAL NOTES
1. BOTTOM OF STRUCTURE BOTTOM OF STRUCTURE BOTTOM OF STRUCTURE BOTTOM OF STRUCTURE BOTTOM OF STRUCTURE 2. 3.
P P

PROVIDE TILE BACKER BOARD AT TILE LOCATIONS. PROVIDE WATER RESISTANT GYP BD BEHIND ALL SINK LOCATIONS. SEE LIFE SAFETY PLANS FOR RATED PARTITION LOCATIONS. ALL PARTITION ARE NON-RATED, UNLESS OTHERWISE NOTED. RATED PARTITION SHALL BE STENCILED ABOVE ACCESSIBLE CEILINGS AT 12' SPACING WITH NOTE INDICATING WALL RATING. (ONE ON EACH WALL). PROVIDE BLOCKING FOR FLAT PANEL TV'S, GRAB BARS, AND OTHER WALL-MOUNTED ELEMENTS. WHERE DISCREPANCIES EXIST BETWEEN THE DETAILS AND THE STC RATINGS INDICATED OR REQUIRED, THE REQUIREMENTS FOR ACHIEVING THE DESIRED STC RATING FOR THE TYPE OF SPACE INDICATED SHALL GOVERN. ACOUSTIC INSULATION SHALL BE PLACED IN ALL WALLS SURROUNDING ROOMS WITH NOISE GENERATION EQUIPMENT AND DEVICES INCLUDED IN THE PROJECT SUCH AS; MECHANICAL EQUIPMENT AND PUMP ROOMS, ELEVATOR EQUIPMENT-MACHINE OR CONTROLLER ROOMS, ELECTRICAL TRANSFORMER AND SWITCHGEAR ROOMS, GENERATOR OR EMERGENCY GENERATOR ROOMS, TOILET ROOMS, CONFERENCE ROOMS, AND OFFICES LOCATED ADJACENT TO PUBLIC ASSEMBLY ROOMS OR TRAFFIC SPACES, AND ROOMS ELSEWHERE INDICATED ON THE PLANS, SECTIONS AND DETAILS. THE MINIMUM STC RATING FOR ANY SPACE SHALL BE 36. THE FOLLOWING MINIMUM STC RATINGS SHALL BE PROVIDED FOR THE ENCLOSURE OF THE FOLLOWING TYPES OF SPACES LISTED, UNLESS NOTED OTHERWISE IN THE DOCUMENTS TO BE HIGHER. A. MECHANICAL ROOM STC 55 B. TOILET/RESTROOMS STC 55 C. MULTI-PURPOSE ROOMS STC 50 D. OFFICES STC 45 PROVIDE A BEAD OF ACOUSTICAL SEALANT AT THE TOP AND BOTTOM OF ALL GYPSUM BOARD WALLS IN ACCORDANCE WITH ASTM C919. WHERE GYPSUM BOARD WALLS TERMINATE AT CURTAINWALL OR OTHER WINDOW AND DOOR FRAMES OF DISSIMILAR MATERIALS, PROVIDE A VERTICAL SEAL OF ACOUSTICAL FOAM TAPE. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES, AND APPLIANCE VENTS LOACTED IN SOUND ASSEMBLIES SHALL BE ISOLATED FROM THE BUILDING CONSTRUCTION BY MEANS OF RESILIENT SLEEVES, MOUNTS, OR 1/4" MINIMUM THICK RESILIENT MATERIALS. ELECTRICAL OUTLET BOXES LOCATED IN OPPOSITE FACES OF SOUND RATED WALLS SHALL BE SEPARATED HORIZONTALLY BY A MINIMUM OF 24". BACKS AND SIDES OF BOXES SHALL BE SEALED WITH 1/8" MINIMUM RESILIENT SEALANT AND BACKED WITH 2" OF MINERAL FIBER INSULATION.

4. BATT INSULATION BATT INSULATION BATT INSULATION 5.

CEILING AS SCHEDULED HEAD 4" CMU


N

CEILING AS SCHEDULED HEAD

TOTAL THICKNESS

CEILING AS SCHEDULED HEAD CMU PER STRUCTURAL DRAWINGS

TOTAL THICKNESS

CEILING AS SCHEDULED HEAD CMU PER STRUCTURAL DRAWINGS

TOTAL THICKNESS

CEILING AS SCHEDULED HEAD

6. 7.
N

4" CMU 5/8" GYPSUM BOARD ON METAL STUDS PLAN PLAN 5/8" GYPSUM BOARD ON METAL STUDS; BOTH SIDES 5/8" GYPSUM BOARD ON METAL STUD PLAN PLAN

CMU PER STRUCTURAL DRAWINGS

8.

PLAN

METAL RUNNER TRACK


M

METAL RUNNER TRACK

METAL RUNNER TRACK


M

FLOOR FINISH AS SCHEDULED

SILL

FLOOR FINISH AS SCHEDULED

SILL

FLOOR FINISH AS SCHEDULED

SILL

FLOOR FINISH AS SCHEDULED

SILL

FLOOR FINISH AS SCHEDULED

SILL

9.

WALL TYPE K
L

RATING ~

STUD 2 1/2"

TOTAL 6 3/4"

UL ~

STC ~

WALL TYPE J

RATING ~

STUD ~

TOTAL 3 5/8"

UL ~

STC ~

WALL TYPE E F

RATING 1 HR 1 HR ~ ~ ~

STUD 2 1/2" & 3 5/8" 2 1/2" 2 1/2" & 3 5/8" 2 1/2" 2 1/2" & 6"

TOTAL 1' 3" 1' 1 7/8" 1' 3" 1' 1 7/8" 1' 4 3/8"

UL U904 U904 ~ ~ ~

STC ~ ~ ~ ~ ~

WALL TYPE B C

RATING 1 HR 1 HR ~ ~ ~

STUD 2 1/2" 3 5/8" 2 1/2" 3 5/8" 6"

TOTAL 10 3/4" 11 7/8" 10 3/4" 11 7/8" 1' 2 1/4"

UL U904 U904 ~ ~ ~

STC ~ ~ ~ ~ ~

WALL TYPE A

RATING ~

STUD ~

TOTAL 7 5/8"

UL ~

STC ~
L

10.

3
K

3
5 1/2" BOTTOM OF STRUCTURE FIRE OR ACOUSTIC SEALANT BOTH SIDES PROVIDE SLIP TRACK EXTENDING 2" ABOVE AND 1" BELOW METAL TRACK ATTACH GYPSUM BOARD TO METAL STUDS BELOW RUNNER TRACK PAINTED MDF 4'-0" OR 7'-0" A.F.F.

G H N

D L M

3
K

11.

12. *PROVIDE HIGH ABUSE GWB AT GAME ROOM

BOTTOM OF STRUCTURE FIRE OR ACOUSTIC SEALANT BOTH SIDES PROVIDE SLIP TRACK EXTENDING 2" ABOVE AND 1" BELOW METAL TRACK ATTACH GYSUM BOARD TO METAL STUDS BELOW RUNNER TRACK BOTTOM OF STRUCTURE ACOUSTICAL SEALANT BOTH SIDES PROVIDE SLIP TRACK EXTENDING 2" ABOVE AND 1" BELOW METAL TRACK ATTACH GYPSUM BOARD TO METAL STUDS BELOW RUNNER TRACK BOTTOM OF STRUCTURE FIRE OR ACOUSTIC SEALANT BOTH SIDES PROVIDE SLIP TRACK EXTENDING 2" ABOVE AND 1" BELOW METAL TRACK ATTACH GYPSUM BOARD TO METAL STUDS BELOW RUNNER TRACK
J

ATTACH GYPSUM BOARD TO METAL STUDS BELOW RUNNER TRACK TOTAL THICKNESS

CEILING AS SCHEDULED HEAD

CEILING AS SCHEDULED TOTAL THICKNESS HEAD METAL STUDS @ 16" O.C. UNO (SEE CHART FOR SIZE) 2 LAYERS ONE SIDE 5/8" GYPSUM BOARD, 1 LAYER OTHER SIDE
H

CEILING AS SCHEDULED HEAD TOTAL THICKNESS

CEILING AS SCHEDULED HEAD METAL STUDS @ 16" O.C. UNO (SEE CHART FOR SIZE) 1 LAYER 5/8" GYPSUM BOARD EACH SIDE
H

TOTAL THICKNESS METAL STUDS @ 16" O.C. UNO (SEE CHART FOR SIZE) 1 LAYER 5/8" GYPSUM BOARD EACH SIDE

HEAD METAL STUDS @ 16" O.C. UNO (SEE CHART FOR SIZE) 2 LAYERS 5/8" GYPSUM BOARD EACH SIDE MECHANICAL ROOM SIDE SOUND ATTENUATION INSULATION, FULL DEPTH OF STUD BOLT TO FLOOR USING CONCRETE ANCHORS METAL RUNNER TRACK BOLT TO FLOOR USING CONCRETE ANCHORS METAL RUNNER TRACK CONCRETE CURB @ MECHANICAL ROOM, SEE STRUCT DWGS FIRE OR ACOUSTIC SEALANT BOTH SIDES FLOOR FINISH AS SCHEDULED 8" SILL ACOUSTIC SEALANT BOTH SIDES FLOOR FINISH AS SCHEDULE METAL STUDS @ 16" O.C. UNO (SEE CHART FOR SIZE) 1 LAYER 5/8" GYPSUM BOARD

BATT INSULATION, FULL DEPTH OF STUD FASTENERS METAL RUNNER TRACK FIRE OR ACOUSTIC SEALANT BOTH SIDES FLOOR FINISH AS SCHEDULED

PLAN PLAN

PLAN

PLAN

BATT INSULATION, FULL DEPTH OF STUD FASTENERS METAL RUNNER TRACK FIRE OR ACOUSTIC SEALANT BOTH SIDES

PLAN

FASTENERS METAL RUNNER TRACK FIRE OR ACOUSTIC SEALANT BOTH SIDES FLOOR FINISH AS SCHEDULED

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

SILL

SILL

SILL

FLOOR FINISH AS SCHEDULED

SILL

WALL TYPE L

RATING ~

STUD 6"

TOTAL 7 7/8"

UL ~

STC 51

WALL TYPE K M

RATING ~ ~

STUD 3 5/8" 3 5/8"

TOTAL 4 7/8" 4 7/8"

UL ~ ~

STC ~ ~

WALL TYPE J

RATING 1 HR

STUD 6"

TOTAL 7 1/4"

UL U419

STC 51

WALL TYPE E F

RATING ~ ~ ~ ~

STUD 1 5/8" 2 1/2" 3 5/8" 6"

TOTAL 2 1/4" 3 1/8" 4 1/4" 6 5/8"

UL ~ ~ ~ ~

STC ~ ~ ~ ~

WALL TYPE A B

RATING 1 HR 1 HR ~ ~

STUD 6" 3 5/8" 6" 3 5/8"

TOTAL 7 1/4" 4 7/8" 7 1/4" 4 7/8"

UL U465 U465 ~ ~

STC 51 51 ~ ~
F

4
*PROVIDE HIGH ABUSE GWB AT GAME ROOM

4
*PROVIDE HIGH ABUSE GWB AT GAME ROOM

G H

C D

BOTTOM OF STRUCTURE SEALANT BOTH SIDES


E E

ATTACH GYPSUM BOARD TO METAL STUDS BELOW RUNNER TRACK PROVIDE SLIP TRACK EXTENDING 2" ABOVE AND 1" BELOW METAL TRACK HEAD CEILING AS SCHEDULED SEE PLAN

METAL STUDS @ 16" O.C. UNO (SEE CHART FOR SIZE) 1 LAYER 5/8" GYPSUM BOARD EACH SIDE BATT INSULATION, FULL DEPTH OF WALL FASTENERS
C

PLAN

METAL RUNNER TRACK ACOUSTIC SEALANT @ PARTION TYPES NOTED W/ ACOUSTIC INSUL BATT SILL FLOOR FINISH AS SCHEDULED

WALL TYPE A

RATING ~

STUD 3 5/8"

TOTAL **

UL ~

STC 55

UNF OSPREY CLUBHOUSE


UNF DRIVE

6
A

PARTITION TYPES
A

CHASE WALLS

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G1.200

10

11

12

13

14

15

16

17

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

PENETRATION DETAIL - UL W-L-1001

PENETRATION DETAIL - UL W-L-3001


D D

UNF OSPREY CLUBHOUSE


UNF DRIVE

UL DETAILS
A A

ONE HOUR RATED PARTITION UL U904

ONE HOUR FIRE RATED PARTITION UL U465


PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G1.201

10

11

12

13

14

15

16

17

SCHEDULE NOTES
COORD ATTACHMENT OF COILING DOOR TO LINTEL W/ STRUCTURE 5/8" GYPSUM BOARD

HOOD

BAFFLE HOOD

CONCRETE LINTEL, SEE STRUCT DWGS

5/8" GYPSUM BOARD

METAL STUD FRAMING

NO 1000-1 1000-2 1000-3 1010-9 1020-9 1040-9 1100-1 1100-2 1100-3 1100-4 1111 1130-9 1140-9 1150-9 1160-9 1200-1 1200-2 1300-9 1310 1311 1400-1 1400-2 1400-3 1400-4 1401-1 1401-2 1500-9 1510-9

WIDTH 6' - 0" 3' - 0" 6' - 0" 6' - 0" 6' - 0" 3' - 0" 16' - 0" 6' - 0" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 16' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 4' - 0" 3' - 0" 3' - 0"

DOOR HEIGHT TYPE 8' - 0" D3 7' - 0" D3 8' - 0" D3 7' - 0" D1 7' - 0" D1 7' - 0" D1 10' - 0" D4 8' - 0" D3 8' - 0" D3 4' - 0" D4 7' - 0" D1 7' - 0" D1 7' - 0" D1 7' - 0" D1 7' - 0" D1 7' - 0" D2 8' - 0" D3 7' - 2" D3 7' - 0" D2 7' - 0" D2 10' - 0" D4 8' - 0" D3 4' - 0" D1 4' - 0" D1 7' - 0" D2 7' - 0" D1 7' - 0" D1 7' - 0" D1

FRAME MATL TYPE MATL ALUM A ALUM ALUM F3 ALUM ALUM D ALUM HM F4 HM HM F4 HM HM F3 HM MTL MFR MTL ALUM K ALUM ALUM K ALUM MTL MFR MTL WD F1 HM WD F1 HM WD F1 HM WD F1 HM WD F1 HM WD BB ALUM ALUM L ALUM ALUM F ALUM WD F1 HM WD F1 HM MTL MFR MTL ALUM G ALUM PLAM F5 WD PLAM F5 WD WD F1 HM HM F3 HM HM F3 HM HM F3 HM

DOOR SCHEDULE - FIRST FLOOR DETAILS HEAD JAMB SILL 3/G2.103 6/G2.103 9/G2.102 3/G2.102 6/G2.102 9/G2.102 3/G2.103 6/G2.103 9/G2.102 1/G2.102 4/G2.102 7/G2.102 1/G2.102 4/G2.102 7/G2.102 1/G2.102 4/G2.102 7/G2.102 1/G2.101 2/G2.101 -3/G2.103 6/G2.103 9/G2.102 3/G2.103 6/G2.103 9/G2.102 1/G2.101 2/G2.101 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 --3/G2.103 6/G2.103 & 6/G2.102 9/G2.102 3/G2.102 6/G2.103 & 6/G2.102 9/G2.102 2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -1/G2.101 2/G2.101 -3/G2.103 6/G2.103 & 6/G2.102 9/G2.102

RATING

S S S S S S S

S S S

2/G2.103 1/G2.102 1/G2.102 1/G2.102

5/G2.103 4/G2.102 4/G2.102 4/G2.102

-7/G2.102 7/G2.102 7/G2.102

HARD WARE 6.0 1.0 2.0 10.0 11.0 9.0 30.0 6.0 6.0 30.0 22.0 24.0 15.0 15.0 16.0 19.0 3.0 5.0 22.0 23.0 30.0 4.0 25.0 26.0 20.0 8.0 7.0 7.0

REMARKS 5,12 1,5,12 1,5,12 2,3,6,7,12 2,3,6,7,12 2,3,6,7,12 4,10 5,12 5,12 4,10 12 9 1,9 1,9 1,9 9,12 5,12 14,12 12 12 4,10,MOTORIZED 5,12 13 13,15 12 2,7,11,12,13 1,2,12 1,2,12

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15.

HANDICAP ASSIST OPERATOR WEATHER STRIPPING AROUND DOOR SOUND SEALS ELECTRONIC HOLD OPENS TIED TO FIRE ALARM TEMPERED GLASS PROVIDE DRIP EDGE ABOVE DOOR TAMPER PROOF HARDWARE 180 DOOR SWING 12" STAINLESS STEEL KICK PLATE ROLL-UP COILING DOOR PEEP HOLE INTELLIKEY SELF-CLOSING HARDWARE NO EXTERIOR HARDWARE DUAL SWING

S = SMOKE TIGHT

GENERAL NOTES
1. REFER TO GLAZING ELEVATIONS FOR ALUMINUM DOOR FRAME TYPES. 2. REFER TO SHEET G2.102 & G2.103 FOR ALL DOOR HEAD, JAMB AND SILL DETAILS. 3. REFER TO SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE.

2 1/2" METAL STUD FRAMING


L

LINTEL BAFFLE

COILING DOOR

1 HEAD @ COILING DOOR


3" = 1'-0" COILING DOOR JAMB

NO 2000-9 2010-1 2010-2 2010-3 2100A-1 2100A-2 2100A-3 2100B-1 2100B-2 2100B-3 2100B-4 2110-9 2120-9 2200-1 2200-2 2201-9 2210-9 2220-9

WIDTH 3' - 0" 3' - 0" 6' - 0" 6' - 0" 3' - 0" 2' - 8" 3' - 0" 4' - 0" 2' - 8" 3' - 0" 5' - 0" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 5' - 0" 3' - 0" 3' - 0"

DOOR HEIGHT TYPE 8' - 0" D3 8' - 0" D3 8' - 0" D3 7' - 0" D1 7' - 0" D2 7' - 0" D1 7' - 0" D2 7' - 0" D2 7' - 0" D1 7' - 0" D2 10' - 0" MFG 7' - 0" D1 7' - 0" D1 7' - 0" D1 7' - 0" D1 7' - 0" D1 7' - 0" D1 7' - 0" D1

FRAME MATL TYPE MATL ALUM G ALUM ALUM G ALUM ALUM Y ALUM WD F2 HM WD F1 HM WD F1 HM WD F1 HM WD F1 HM WD F1 HM WD F1 HM MFG MFG MFG WD F2 HM WD F2 HM WD F1 HM WD F1 HM WD F2 HM WD F1 HM WD F1 HM

DOOR SCHEDULE - SECOND FLOOR DETAILS HEAD JAMB SILL 3/G2.103 6/G2.102 & 6/G2.103 8/G2.102 3/G2.103 6/G2.102 & 6/G2.103 8/G2.102 3/G2.103 6/G2.103 8/G2.102 2/G2.103 3/G2.101 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 ----1/G2.103 4/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 -2/G2.103 5/G2.103 --

4. VERIFY THE CORRELATION OF ALL DOORS AND WINDOW FRAMING MEMBERS AND THEIR RESPECTIVE POSITIONS CONTAINED WITHIN THE WIDTH OF THE PARTITION REQUIREMENTS WITH THE SCHEDULED WALL/PARTITION TYPES, DIMENSIONS AND DETAILS SHOWN ON THE DRAWINGS. BRING DESCREPANCIES TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE PRODUCTION OF SHOP DRAWING SUBMITTALS. WHERE DISCREPANCIES EXIST, CORRECTIONS SHALL BE MADE AS DIRECTED BY THE ARCHITECT. THIS MAY INCLUDE CHANGES IN ONE FRAME PROFILE TYPE TO ANOTHER AS NECESSARY IN THE OPINION OF THE ARCHITECT. 5. APPLY SEALANT AT ALL OPEN JOINTS WHERE FRAMES CONNECT TO THE WALL FINISH. SEE SPECIFICATION FOR TYPE OF SEALANT.

6"

RATING

S 60 MIN S

HARD WARE 4.0 4.0 6.0 12.0 13.0 21.0 13.0 14.0 21.0 13.0 31.0 29.0 27.0 18.0 19.0 28.0 22.0 17.0

REMARKS
5,12 5,12 5,12 4,9,13 9,12 12 9,12 9,12 12 9,12 BY OPERABLE PARTITION MFG 3,9,12 9,12 9,12 9,12 12 9,12 1,9,12

6. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF U.L. LABELED HARDWARE WITH SCHEDULED RATED DOORS AND DOOR FRAMES TO ASSURE CODE CONFORMING RATED ASSEMBLIES. 7. CONTRACTOR SHALL COORDINATE WITH BUILDING AUTOMATION CONTRACTOR ALL CONDUIT AND JUNCTION BOXES ASSOCIATED WITH SECURITY HARDWARE BEING INSTALLED OR EMBEDDED WITHIN DOOR FRAMES. 8. ALL DOORS TO ROOMS REQUIRING RATINGS OF STC 50 OR GREATER SHALL CONTAIN SOUND SEALS. 9. FOR ANY HARDWARE SET COMBINATIONS NOT SHOWN, NEW SETS WILL BE CREATED.

COILING DOOR

SEE SCHEDULE

SEE SCHEDULE

SEE SCHEDULE 1' - 0" 6" 6"

SEE SCHEDULE 5" 5" SEE SCHEDULE

2' - 8"

5"

SEE SCHEDULE

SEE SCHEDULE

SEE SCHEDULE

SMOKETIGHT SEAL

3' - 4"

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

D1

D2

10"

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

EXIT DEVICE, WHERE INDICATED

D3

D4

DOOR TYPES
5/8" GYPSUM BOARD

METAL STUD FRAMING

2
F

JAMB @ COILING DOOR


3" = 1'-0" 2"

2"

SEE SCHED

2"

2"

SEE SCHED

2"

2"

SEE SCHED

2"

2"

SEE SCHED

2"
F

4"

2"

4"

2" SEE SCHED SEE SCHED SEE SCHED SEE SCHED

SEE SCHED

2"

SEE SCHED

F1

F2

F3

F4

F5

FRAME TYPES
ALUMNINUM BREAK METAL COVER TO MATCH FRAME

BATT INSULATION 3 5/8" METAL FRAMING 5/8" GYP BD, PAINTED

6" METAL FRAMING


C C

SEALANT BEAD CONTINUOUS AROUND FRAME AT BOTH SIDES

HM FRAME, PAINTED 3"

UNF OSPREY CLUBHOUSE


UNF DRIVE

MAGNETIC RELEASE TO BE TRIGGERED BY FIRE ALARM DOOR HINGE WOOD DOOR, SEE SCHEDULE

6"

DOOR SCHEDULES DOOR & FRAME TYPES


A PROJECT NO:

3
2 1

JAMB @ HM HOLD OPEN


3" = 1'-0"

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3

G2.101

10

11

12

13

14

15

16

17

7" WEATHER BARRIER OVER CMU WALL


P

7" WEATHER BARRIER OVER CMU WALL 1 1/2" CONT RIGID INSULATION MORTAR MESH BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN CONCRETE LINTEL REFER TO STRUCTURAL DRAWINGS 5/8" GYPSUM BOARD, PAINTED CONCRETE LINTEL REFER TO STRUCTURAL DRAWINGS WEATHER BARRIER OVER CMU WALL
P

1 1/2" CONT RIGID INSULATION MORTAR MESH BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN

1 1/2" CONT RIGID INSULATION MORTAR MESH BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN CONCRETE LINTEL - REFER TO STRUCTURAL DRAWINGS

CONT. METAL THRUWALL FLASHING

CONT. METAL THRUWALL FLASHING

2 1/2" METAL STUD FRAMING

2 1/2" METAL FRAMING CONT. METAL THRUWALL FLASHING 5/8" GYPSUM BOARD
N

WEEP VENTS @ 24" OC

SEALANT

WEEP VENTS @ 24" OC

SEALANT

WEEP VENTS @ 24" OC CORNER BEAD

BRICK ANGLE, PAINTED SEALANT AND BACKER ROD

HM FRAME FILLED WITH GROUT, PAINTED

BRICK ANGLE, PAINTED SEALANT AND BACKER ROD

HM FRAME FILLED WITH GROUT, PAINTED

BRICK ANGLE, PAINTED CONT. SEALANT

RO

CONT. SEALANT AND BACKER ROD 3/8" MIN.

6"

HM DOOR, PAINTED

HM DOOR, PAINTED

ALUMINUM DOOR FRAME

5 1/2"

8 3/4"

6"

1' - 0 1/4" 6"

HEAD @ HM
3" = 1'-0"

HEAD @ HM
3" = 1'-0"

HEAD @ ALUM
3" = 1'-0"

2 1/2" METAL FRAMING HM FRAME, PAINTED, GROUT SOLID 8" CMU 2 1/2" METAL FRAMING 8" CMU
J J

HM FRAME, PAINTED, GROUT SOLID 5/8" GYPSUM BOARD

5/8" GYPSUM BOARD

8" CMU

CORNER BEAD

1 15/16"

1 15/16"

CONT. SEALANT

1' - 0 1/4"

7 3/4"

3 7/8"

8 3/8"

ALUM DOOR FRAME


ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

1 15/16"

1 15/16"

NO
6" 7" 2" RO
G

2" RO 6" 7"

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

CONT. SEALANT AND BACKER ROD 3/8" MIN.

WEATHER BARRIER 1 1/2" RIGID CONTINUOUS RIGID INSULATION BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN CONT. SEALANT AND BACKER ROD 3/8" MIN. WEATHER BARRIER 1 1/2" RIGID CONTINUOUS RIGID INSULATION BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN CONT. SEALANT AND BACKER ROD 3/8" MIN. WEATHER BARRIER 1 1/2" RIGID CONTINUOUS RIGID INSULATION BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN

7"

RO

6"

JAMB @ HM CMU
3" = 1'-0"

JAMB @ HM CMU
3" = 1'-0"

JAMB @ ALUM CMU


3" = 1'-0"

CONTINUOUS BACKER ROD AND SEALANT ALUMINUM OUTSWING DOOR, SEE SCHEDULE ALUMINUM THRESHOLD SET IN SEALANT MASTIC. SEAL THRESHOLD TO JAMB COMPOSITE SLAB, SEE STRUCT DWGS 1/2" 1/2" MAX. CONCRETE SIDEWALK, SEE CIVIL DRAWINGS

ALUMINUM DOOR, SEE SCHEDULE

DOOR, SEE SCHEDULE

1/2" COMPRESSIBLE FILLER

CONTINUOUS BACKER ROD AND SEALANT

ALUMINUM THRESHOLD SET IN SEALANT MASTIC

URETHANE PEDESTRIAN TRAFFIC COATING, DETAIL IN ROUGH OPENING

1/2" COMPRESSIBLE FILLER SLOPE SLOPE

ALUMINUM THRESHOLD SET IN SEALANT MASTIC. SEAL THRESHOLD TO JAMB


C

SLOPE

CONCRETE SIDEWALK, SEE CIVIL DRAWINGS

UNF OSPREY CLUBHOUSE


UNF DRIVE

7
A

SILL @ HM
3" = 1'-0"

SILL @ ALUM BALCONY


3" = 1'-0"

SILL @ ALUM ENTRY


3" = 1'-0"
A

DOOR DETAILS

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G2.102

10

11

12

13

14

15

16

17

7 1/2"

METAL STUD FRAMING W/ BATT INSULATION (2) LAYER 5/8" GYPSUM BOARD BOTH SIDES

METAL STUD FRAMING W/ BATT INSULATION 5/8" GYPSUM BOARD

GLASS, SEE GLAZING ELEVATIONS

ALUMINUM, CURTAIN WALL FRAME


N

1/2"

1/2"

1/2"

ALUMINUM DOOR, SEE SCHEDULED HM FRAME, PAINTED

2"

2"

HM FRAME, PAINTED

5/8"

DOOR STOP

SCHED. DIM.

DOOR, SEE SCHEDULE

5/8"

2 1/2"

SEALANT BEAD CONT AROUND FRAME AT BOTH SIDES

1/2"

SEALANT BEAD CONT AROUND FRAME BOTH SIDES

DOOR, SEE SCHEDULE

WALL WIDTH +1"

WALL WIDTH +1"

1
L

HEAD @ HM 2 LAYER
3" = 1'-0"

HEAD @ HM
3" = 1'-0"

HEAD @ ALUM
3" = 1'-0"

SEALANT BEAD CONTINUOUS AROUND FRAME AT BOTH SIDES HM FRAME, PAINTED DOOR, SEE SCHEDULE 1/2"
K

METAL STUD FRAMING W/ BATT INSULATION

SEALANT BEAD CONTINUOUS AROUND FRAME AT BOTH SIDES HM FRAME, PAINTED ALUMINUM FRAME DOOR, SEE SCHEDULE DOOR STOP
0' - 6"

GLASS, SEE GLAZING ELEVATIONS

WALL WIDTH +1"

5/8"

2" GYPSUM BOARD

1/2"

SCHED. DIM.

2 1/2"

7 1/2"

ALUMINUM DOOR, SEE SCHEDULE

(2) LAYER 5/8" GYPSUM BOARD

METAL STUD FRAMING W/ BATT INSULATION

4
H

JAMB @ HM 2 LAYER
3" = 1'-0"

JAMB @ HM
3" = 1'-0"

JAMB @ ALUM
3" = 1'-0"
H
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

UNF OSPREY CLUBHOUSE


UNF DRIVE

DOOR DETAILS
A A

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

G2.103

10

11

12

13

14

15

16

17

GENERAL NOTES
1. SEE EARLY SITE PACKAGE DATED 03/14/13 FOR CIVIL DOCUMENTS.

OSPREY COVE
L L

OSPREY VILLAGE
EXISTING UTILITY YARD. REPLACE EXISTING FENCE WITH SIMILAR BOARD ON BOARD PAINTED FENCE.
K K

SIM 1 A0.102

UNF D RIVE

POOL

NEW TWO-STORY CLUBHOUSE


G

SERVICE YARD

LOADING ZONE

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

1 ARCHITECTURAL SITE PLAN


1" = 20'-0"
B B

UNF OSPREY CLUBHOUSE


UNF DRIVE

ARCHITECTURAL SITE PLAN


A A

NORTH
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

PROJECT NO:

120063.00

A0.101

10

11

12

13

14

15

16

17

8' HIGH ALUMINUM FENCE

38' - 8"

6. 0

BRICK SCREEN WALL


5 x PIPE DIAMETER

N
8. 0

PRECAST CAP AREA DRAIN HOUSEKEEPING PAD-SEE STRUCTURAL CHILLERS-SEE MECHANICAL


FD

ALUMINUM TUBE FRAME W/ ALUMINUM PICKETS


N

6. 0

TS 6"X6"X1/2" - PAINTED 5 A0.102

10 x PIPE DIAMETER

LIF

T EMPT O NLY

L IFT EMPTY O NLY

2 A0.102 44' - 8"

48' - 8"

4'-0" GATE & FENCE A2.302 L4 5'-0" WIDE GATE 3 A0.102 80' - 8"

5' - 0"

AREA DRAIN
K

16' - 0"

BOLLARD 16' - 0"

1 1/2"

TRANSFORMER

8" CMU GROUT SOLID - PAINTED

2 1/2"

MDP - SEE ELECTRICAL

2 1/2"

FD

1
G

SERVICE YARD
1/8" = 1'-0"

17

16

15

14

13

12

11

10

T EMPT LIF O NLY Y

ALUMINUM FENCE-SEE SPECS

4. 0

MASONRY WALL TIE @ 24" O.C. VERT. (TYP) STONE BRICK VENEER
M

12'-0" GATE R.O.

8" CMU GROUT SOLID PAINTED

BOLLARD

CONDENSERS, SEE KITCHEN DRAWINGS 12'-0" GATE & FENCE

SERVICE YARD TYP. GATE JAMB


1 1/2" = 1'-0"

4 A0.102

OIL DRUM BY OWNER

FD

4 A0.102 BOLLARD

SIM

STONE OVER WEED BARRIER

PRECAST CAP (ABOVE) 6"

1' - 2" 8"

BRICK VENEER BRICK VENEER

DRIP - TYPICAL BOTH SIDES OF CAP

CONCRETE LINTEL SEE STRUCTURAL 4'-0" GATE 5' - 2" 39' - 2" 8" CMU GROUT SOLID PAINTED
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

SECTION THROUGH SCREEN WALL


3/4" = 1'-0"

CORNER DETAIL
1 1/2" = 1'-0"

PRECAST CAP DETAIL


1 1/2" = 1'-0"

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

UNF OSPREY CLUBHOUSE


UNF DRIVE

SERVICE YARD PLAN & DETAILS


A

NORTH
2 1

PROJECT NO:

120063.00

A0.102

10

11

12

13

14

15

16

17

GENERAL NOTES
3 COAT CEMENT PLASTER ON 4" CMU 1. SECURE ALL MAILBOX UNITS TO CMU WALLS AND PODIUM. 2. PROVIDE METAL INFILL PANELS TO CLOSE OFF ALL GAPS AND OPENINGS.

1 E E
5 A0.103 8" CMU WALL BREAK METAL INFILL PANEL, MATCH MAILBOX 5 A0.103 BREAK METAL TOP, SLOPED - FINISH TO MATCH MAILBOX ALUMINUM MAILBOX-SEE SPECS 2' - 10" 1' - 5"

BREAK METAL TOP, SLOPED FINISH TO MATCH MAILBOX

ALUMINUM MAILBOXES

BREAK METAL INFILL PANEL

PRE-FINISHED GUTTER AND DOWNSPOUT SYSTEM-TIED TO STORM 2' - 10" 11' - 8"

5' - 4"

3 COAT CEMENT PLASTER ON 4" CMU 7' - 4" A0.103 4 ALUMINUM MAILBOX-SEE SPECS 2' - 10"

7' - 4"

5' - 4"

BREAK METAL INFILL TO MATCH MAILBOXES

4" CMU WALL 4" 6' - 8"

3 COAT CEMENT PLASTER ON 8" CMU

1' - 8"

A0.103

FIRST FLOOR 0' - 0"

1' - 5"

3 COAT CEMENT PLASTER ON 8" CMU

1' - 8"

3 COAT CEMENT PLASTER ON 8" CMU

4"

FIRST FLOOR 0' - 0"


1' - 0"

CMU COLUMN, SEE STRUCT DWGS

1 MAILBOX (2 UNIT) - TYP. OF 8 LOCATIONS


1/2" = 1'-0"

2 MAIL BOX (2 UNIT)


1/2" = 1'-0"

3 MAILBOX (8 UNIT) - TYP. OF 11 LOCATIONS


1/2" = 1'-0"

4 MAILBOX (8 UNIT)
1/2" = 1'-0"

BRICK VENEER, SEE ELEVATION FOR SIZES AND PATTERN

RIGID INSULATION

8" CMU WALL BRICK SOLDIER COURSE


H H
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

2 1/2" METAL FRAMING BREAK METAL TOP SLOPED - FINISH TO MATCH MAILBOX GYP BD, PAINTED

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

ALUMINUM MAILBOXES

5' - 4"

CONCRETE PLATFORM, SEE STRUCT DWGS


E

1' - 8" 4" 1' - 4"

CEMENT PLASTER FINISH 2' - 0"


D

HARDSCAPE, SEE LANDSCAPE DWGS

FIRST FLOOR 0' - 0"

CONCRETE FOOTING, SEE STRUCT DWGS

UNF OSPREY CLUBHOUSE


UNF DRIVE

5
A

MAILBOX SECTION
1" = 1'-0"

MAIL BOX DETAILS


A

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

A0.103

10

11

12

13

14

15

16

17

GENERAL NOTES
BLOCKING AT 60" AFF

A2.101 5
M

4 A3.101 A2.101 4 3 A3.101 2 A3.102

A
" 12' - 0

1 A3.102

B
2 1
1/2" 2' - 3

A3.101

C
24' - 0"

2 A2.201

A2.201 3
1 '0 " 2' - 1 5/8

A4.104

0 5/8"

" 14' - 0

D
8. 0

9' - 6"

J
5 x PIPE DIA

2 ' 14 " -0

Zb
TV 5 .7 162 7 A7.302
78 .0 0

Zd
3

4 A1.301

24' - 0"

4 A6.101
24' - 0"

5/ 8"

A7.302 ADA PUSHPAD (TYP) 1000-3 D


2' - 0"

10

2' -

1400-2

22' - 0"

LI FT MPT ON E L Y Y

Z2
11 /1 6"
J

14 '

-0 "

TV 50 2. 6 1

2' - 0 " 22' - 0"

L IFT E MPTY O NLY

UP

H 3D
37' - 0"
FD

1100-3

2' - 0"

2' -

1
5/8 "

10

GAME ROOM
1100

A3.101

4M 18' - 8"
18' - 8"

L4

10

TV
16 2.7 5

1 A4.101

2' -

1100-1

1400-1

GRILL
1400
15' - 9 1/2"

-0 "

LOBBY
1000-9 J 3 A1.301 3M 4J
154.0 0

1400-3

14'

80' - 8"

3D 3D
11' - 4"

4' - 0 "

4A
8' - 8 "

31' - 4"

6 A6.201

4K COOLER FREEZER 1400-4 4K 4K AA


2' - 02 "' -

2' - 0 "

/8"

3C 3D

2' - 4"

43

8' - 0"

4L TV 1100-4

2' -

A7.201

3G

4K

24' - 0"

5 A6.111

3D

4C

ELEVATOR
1 1306-9 3B 3B

3' - 6"

2' - 8"

MECHANICAL
11' - 3" 1010-9 4J

A7.201 3 A7.301

1401 1401-1
1' - 4 "

6' - 4"

STORAGE
1111 1111

2' - 0"

1010-9

1110

3B 4G 4G

1310 8 17' - 0 1/2" A6.101 4C 4C 1310 1 4C A7.302


34' - 9"

2' - 0"

3A

3D

DESK
2 A4.101

OFFICE

3E

3E

4C

8' - 8"

1020-9

1140-9

1500-9

1130-9

1500-9

38' - 6"

3K 3J

1140-9 6A

4C

FAAP
3' - 4"

CORRIDOR
1300-9

4G

4C

3 ADA PUSHPAD (TYP) VESTIBULE 1120-9 A4.102

RA PROJECTS
1311

ELECTRICAL
19' - 8"

1040-9
9' - 4"4C

1311 1000-2
6' - 8 "

4J
FD

12' - 0"

20' - 8"

HYDRATION STATION 1150-9 1160-9 6A 3K

E
5' - 4 " 6' - 8 "

1300-9

F
5' - 4 "

MECHANICAL
E
6' - 8 " 5' - 4 " 6' - 8 "

4J
3' - 4 " 5' - 0 "

83' - 8"

3J

26' - 0"

A2.102 1

L1

WOMEN

MEN

3C

1130-9

1' - 4 "

1040-9

4C

JANITOR

1401-2 4' - 4 " 3' - 0 " 8' - 8 " 18' - 4" 6' - 4 " 2' - 0 " 3 ' - 4" 5' - 4 "

4"

TV

KITCHEN

7' - 4"

2' - 0"

2' - 8"

1020-9 E
5' - 4 " 6' - 8 "

1510-9

3J

8' - 0"

L1

1510-9

3J

4G

1200-1

MEN

WOMEN
1150-9 4C

FAMILY
1160-9

3M 3N 8' - 8"

L3 E
5' - 4 " 6' - 8 "

E
5' - 4 " 6' - 8 "

E
5' - 4 " 6' - 8 "

4C 4' - 0"
E

L2

4G 1200-2

D/D D/D D/D D/D D/D D/D D/D D/D 7" 4' - 8" 4C TV ICE
FD

3' - 4 "

FD

10' - 0"

11"

1200

1000-1

Z1

16' - 0" 16' - 0" 8' - 0 " 8' - 0 " 16' - 0"

5' - 8"

3 A5.101

ADA PUSHPAD ON PRE-FINISHED ALUMINUM STANCHION

LAUNDRY

2' - 1 "

8' - 0 "

C L 2' - 8"

M
D

19' - 4"

5' - 4"

29' - 4"

4' - 0"

16' - 0"

A.3 B
2 A2.101

3 A0.103

1
C

Za

Zc

B.7

A2.101

C.3 D E

1 FIRST FLOOR PLAN


1/8" = 1'-0"
A A

17

16

15

14

4. 0

2'

3' - 0 "

POOL EQUIPMENT YARD

CONDENSERS, SEE KITCHEN DWGS

1 A0.103

EMPTY L IFT NLY O

-1

" 5/8

A2.102

10 x PIPE DIAME TE

1100-2

METER

6. 0

6. 0

9' -6 "

1 A0.102 PUMP PAD CHILLER

CHILLER
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

3 A2.101
FD

TRANSFORMER

2 A2.102

UNF OSPREY CLUBHOUSE


UNF DRIVE

FIRST FLOOR PLAN

NORTH
13 12 11 10 9 8 7 6 5 4 3 2 1

PROJECT NO:

120063.00

A1.101

10

11

12

13

14

15

16

17

A2.101 5
M M

4 A3.101

2 A3.101 A2.101 4

3 A3.101

1 2 A3.102 A3.102
24' - 0"

2 A2.201 CC 2 A1.301
2' - 8"

24' - 0"

Zb
K

Zd
1 A4.104
3' - 0 " 22' - 0" 2' - 0 "

24' - 0"
K

CC A2.301 CC 2' - 6"

6 A4.303 7' - 0 1/4" 19' - 4"

10' - 8"

1' - 5" 2000-9


" 4' - 4 1 /4

22' - 0"

3 A6.101
1' - 4"
6' - 8 " 2' - 0 "

D CONT

3 G2.101

UP 2010-2 2010-3
4' - 4 9 /16"

22' - 0"

6' - 9"

12' - 0"

13' - 4"

Z2

CC

Y G OPP 2010-1

6' - 5 "

R4 1' -

1' - 9"

1 4C A5.101

2
3 X A2.102

6' - 5 "

5"

3' - 10"

8' - 6"

1 A4.101

2220-9

4C 4C

10' - 0"

4C 2100A-1

2100A-2

OPEN TO BELOW

MDF
2210-9 2210-9

A7.302 2

6' - 0 "

CORRIDOR
2010-9
2' - 6"

7' - 10"

UNISEX
2220-9

4C 2100A-3

6' - 0 " 8' - 10" 3' - 10" 7' - 0 "

2000-9
8' - 0"

2100B-3

4C

A7.302 4C 3 2100B-2

8' - 1"

CORRIDOR
CC
H

W
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

4C 4C 3C ICE

2100B-4 4C

4C 4

2200-9
7' - 10"

A7.302 4C 2200-1
4' - 10 1

3B

3B

2100B-1

2200-2

PREP KITCHEN

4D 4B

4G 73' - 11"
6' - 7" 4B
G

38' - 10 "

MULTI-PURPOSE A
2100-A

2 A4.101

76' - 0"

3B

4G

STORAGE
4C 2120-9 4C 2120-9 4G 4C 5 A6.101

MULTI-PURPOSE B
2100-B

9' - 8 " 1' - 8 " 6' - 0 "


G

52' - 0"

2' - 0 "

23' - 4"

2201-9

31' - 4"

ELEV EQUIP

NO

/2"

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

L5

3 A2.101 1 A3.101

A2.102 1 4C

3 A4.102
F

4J
F

MECHANICAL
2110-9

11' - 6 3

/8"

20' - 8"

2110-9

2 A2.102

2' - 1"

Z1

C CONT A CONT 9' - 10 5/8"

B CONT

6 A4.303
D

1 A A.3 B
1
C

2 A2.101

B.7

Za

Zc

C.3 D E

A2.101

SECOND FLOOR PLAN


1/8" = 1'-0"

UNF OSPREY CLUBHOUSE


UNF DRIVE

SECOND FLOOR PLAN


A A

NORTH
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

PROJECT NO:

120063.00

A1.102

10

11

12

13

14

15

16

17

1' - 0"

2' - 0"

L2

Z1
M

10' - 1"

1' - 0"

L CONT

6' - 2"

M CONT 5' - 8" 8' - 0"

8' - 0"

8' - 0"

5' - 2"

1 CLERESTORY PLAN - LAUNDRY


1/8" = 1'-0"
K K

1 A4.104

21' - 10 5/8"
H

G D CONT 2' - 5" Z Y CONT G OPP CONT 3 R X CONT A2.102 CONT

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

8' - 0"

8' - 0"

R W CONT
8' - 1"

R 8' - 0"
F

8' - 0"

8' - 0"

6' - 0 "

2' - 0 "

L5
E E

8' - 0"

T R S 2' - 0 "

3 A4.102

2' - 7"

8' - 0 "

R
8' - 0 "

8' - 0"

8' - 0 "

R
8' - 0 " 8' - 0 "

R
8' - 0 "

R
8' - 0 "

21' - 3"

8' - 0"

R R

15' - 4"

R 8' - 0 "

23' - 4"

31' - 5"

8' - 0"

V
8' - 0 "

R
8' - 0 "

R
6' - 3 "

9' - 8"

B CONT C

18' - 10 "

5' - 5"

8' - 0 "

R R

CONT A CONT 9' - 10 5/8"

UNF OSPREY CLUBHOUSE


UNF DRIVE

2
A

CLERESTORY PLAN - SECOND FLOOR


1/8" = 1'-0"

CLERESTORY PLAN
A

NORTH
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

PROJECT NO:

120063.00

A1.103

10

11

12

13

14

15

16

17

4 A3.101 3 A3.101

2 A3.101

2 A3.102 1
K

A3.102

PRE-FINISHED STANDING SEAM METAL ROOFING ON WATERPROOF MEMBRANE OVER PLYWOOD DECKING

2 A2.201
2" /1 " '-0

1 A4.104
J

1'-0" 1/2" /

PRE-FINISHED ALUMINUM GUTTER AND DOWNSPOUT SYSTEMTIED TO STORM (TYP).


"/ 1 /2

4" / 1'-0 "

4" / 1'-0 "

2"

4" / 1'-0"

0" 1'H
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

/1 '-0 "

1/

2" /

1' -0 "

3 A2.102

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

2"

1/ 2 "/ / 1' -0"

ROOF MEMBRANE OVER TAPERED RIGID INSULATION SLOPED TO DRAIN


1'-0 "
4" / 1'-0 "

2' X3' ROOF HATCH 4" / 1'-0"

1 A4.302 ROOF MEMBRANE OVER TAPERED RIGID INSULATION SLOPED TO DRAIN RD OD OD 1 A3.101 4" / 1'-0"
4" / 1'-0 "

RD 6 A4.301 ROOF WALKWAY PAD


F

3 A4.102
E

4" / 1'-0 "

STANDING SEAM METAL ROOF

4" / 1'-0"

4" / 1'-0 "

4" / 1'-0"

4" / 1'-0"

4" / 1'-0 "

4" / 1'-0"
2" / 1'-0 "

4" / 1'-0"

2 A2.102

4" / 1'-0"

4" / 1'-0"

PRE-FINISHED ALUMINUM GUTTER AND DOWNSPOUT SYSTEMTIED TO STORM (TYP).


B B

UNF OSPREY CLUBHOUSE


UNF DRIVE

1
A

ROOF PLAN
1/8" = 1'-0"

ROOF PLAN
A

NORTH
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

PROJECT NO:

120063.00

A1.104

10

11

12

13

14

15

16

17

METAL FURRING 8" CMU WALL

BOND BEAM, SEE STRUCT DWGS

GYP BOARD, PAINTED


M M

WALL-MOUNTED TV

3' - 4"

6" GYP BOARD OVER 1 5/8" METAL FRAMING

6"

3-COAT CEMENT PLASTER, PAINTED


J

6"

CENTER OF TV

4" CMU INFILL

5' - 0"

CMU COLUMN, SEE STRUCT DWGS

3' - 4"

LINE OF BRICK BELOW


H

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

PRECAST CAP

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

MITERED CORNER, GROUT TO MATCH PRECAST CAP 6"


F

1
E

TV NICHE SECTION
1 1/2" = 1'-0"

COLUMN DETAIL
1 1/2" = 1'-0"

4"

1' - 4"

4" BRICK VENEER

1 A1.301
D

4"

6' - 8"

GYP BOARD, PAINTED WALL MOUNTED TELEVISION

CMU COLUMN, SEE STRUCT DWGS

EQ

EQ

2' - 8"

PRECAST CONCRETE ACCENT BAND

1 5/8" METAL FRAMING


B

4" CMU INFILL 4" 8" CMU INFILL

UNF OSPREY CLUBHOUSE


UNF DRIVE

PLAN DETAILS
A

3
2 1

TV NICHE PLAN DETAIL


1 1/2" = 1'-0"

4
12 11 10 9 8 7 6 5 4

COLUMN BASE DETAIL


1 1/2" = 1'-0"
A

PROJECT NO:

120063.00
17 16 15 14 13 3

A1.301

10

11

12

13

14

15

16

17

GENERAL NOTES
2 A3.102 4 MATCH LINE A3.101
P

1. ELEVATION 0'-0" IS EQUAL TO FINISHED FLOOR ELEVATION INDICATED ON CIVIL DRAWINGS.

MATCH LINE

Za

Zc

A.3

B.7

C.3

E
PREFINISHED STANDING SEAM METAL ROOF

2. ALL EXTERIOR WINDOW AND DOOR SYSTEMS SHALL COMPLY TO SECTION 1609 - WIND LOADS OF THE FLORIDA BUILDING CODE. 3. VERTICAL CONTROL JOINTS TO MATCH BRICK IN COLOR. HORIZONTAL CONTROL JOINTS TO MATCH GROUT COLOR.

1" INSULATED GLAZING IN ALUMINUM WINDOW SYSTEM

1" INSULATED GLAZING IN ALUMINUM WINDOW SYSTEM

TRUSS BEARING 26' - 0"


PREFINISHED STANDING SEAM METAL ROOF PREFINISHED METAL GUTTER & DOWNSPOUT SYSTEM, TIED TO STORM 4" 1'-0"

DECORATIVE ALUM KICKER (TYP OF 2)

TRUSS BEARING 26' - 0"


PREFINISHED METAL GUTTER & DOWNSPOUT SYSTEM, TIED TO STORM BRICK VENEER

SECOND FLOOR 14' - 0"


M

SECOND FLOOR 14' - 0"


M

BRICK VENEER

FIRST FLOOR 0' - 0"


L

PREFINISHED ALUMINUM CANOPY OVER DOOR

FIRST FLOOR 0' - 0"


SERVICE YARD GATE, SEE SPECIFICATIONS ALUMINUM MAILBOX UNITS, SEE A0.103 PREFINISHED HM LOUVER, SEE MECH DWGS
L

1
K

WEST ELEVATION
1/8" = 1'-0"

WEST ELEVATION
1/8" = 1'-0"
K

2 A2.102
J

1 A3.101

3 A2.102

1
PREFINISHED STANDING SEAM METAL ROOF PREFINISHED METAL GUTTER & DOWNSPOUT SYSTEM, TIED TO STORM 4" 1'-0"

2
1" INSULATED GLAZING IN ALUMINUM WINDOW SYSTEM

MATERIAL LEGEND
B-1 4" X 8" BRICK MANUFACTURER: CHEROKEE BRICK AND TILE CO COLOR: TBD EXTERIOR PAINT MANUFACTURER: SHERWIN WILLIAMS COLOR: TBD

EP-1

TRUSS BEARING 26' - 0"


BRICK VENEER 1'-0" 2" PREFINISHED ALUMINUM MESH GUARDRAIL SYSTEM

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

SECOND FLOOR 14' - 0"


G G

ALUMINUM MAILBOX UNITS, SEE A0.103 8' - 4"

SERVICE YARD GATE, SEE SPECIFICATIONS


F

WALL-MOUNTED EXTERIOR LIGHT FIXTURE

MAKE UP AIR DUCT PENETRATION, SEE KITCHEN DWGS KITCHEN EXHAUST FAN, SEE KITCHEN DWGS STAINLESS STEEL PROTECTIVE WALL PANEL, LOCATE BELOW GREASE VENT

FIRST FLOOR 0' - 0"


1 A2.201 3-COAT CEMENT PLASTER OVER PAPER-BACKED METAL LATH, PAINTED BRICK VENEER COLUMN BASE
F

3
E

SOUTH ELEVATION
1/8" = 1'-0" 2 A3.102

MATCH LINE

C.3

B.7

A.3

A
MATCH LINE PREFINISHED STANDING SEAM METAL ROOF

Zd
1 A4.104

Zb

4 A3.101

PREFINISHED STANDING SEAM METAL ROOF

DECORATIVE ALUM KICKER (TYP OF 2)


D D

PREFINISHED METAL GUTTER & DOWNSPOUT SYSTEM, TIED TO STORM PREFINISHED HM LOUVER, SEE MECH DWGS BRICK VENEER

TRUSS BEARING 26' - 0"

PREFINISHED METAL GUTTER & DOWNSPOUT SYSTEM, TIED TO STORM BRICK VENEER

3-COAT CEMENT PLASTER OVER PAPER-BACKED METAL LATH, PAINTED

TRUSS BEARING 26' - 0"

BRICK SCREEN WALL

SECOND FLOOR 14' - 0"

SECOND FLOOR 14' - 0"

FIRST FLOOR 0' - 0"


B

FIRST FLOOR 0' - 0"


B

SERVICE YARD GATE, SEE SPECIFICATIONS

PRECAST CONCRETE STAIR, WITH TRAFFIC COATING

1" INSULATED GLAZING IN ALUMINUM WINDOW SYSTEM

3-COAT CEMENT PLASTER OVER PAPER-BACKED METAL LATH, PAINTED BRICK VENEER COLUMN BASE

PREFINISHED ALUMINUM CANOPY OVER DOOR 1" INSULATED GLAZING IN ALUMINUM WINDOW SYSTEM

UNF OSPREY CLUBHOUSE


UNF DRIVE

PREFINISHED ALUMINUM MESH GUARDRAIL SYSTEM

EXTERIOR ELEVATIONS
A

4
1

EAST ELEVATION
1/8" = 1'-0"

5
9 8 7 6 5 4 3

EAST ELEVATION
1/8" = 1'-0"

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 2

A2.101

10

11

12

13

14

15

16

17

GENERAL NOTES
Z2
3 A4.102
P P

Z1

1. ELEVATION 0'-0" IS EQUAL TO FINISHED FLOOR ELEVATION INDICATED ON CIVIL DRAWINGS. 2. ALL EXTERIOR WINDOW AND DOOR SYSTEMS SHALL COMPLY TO SECTION 1609 - WIND LOADS OF THE FLORIDA BUILDING CODE. 3. VERTICAL CONTROL JOINTS TO MATCH BRICK IN COLOR. HORIZONTAL CONTROL JOINTS TO MATCH GROUT COLOR.

1" INSULATED GLAZING IN ALUMINUM WINDOW SYSTEM PREFINISHED STANDING SEAM METAL ROOF PREFINISHED METAL GUTTER & DOWNSPOUT SYSTEM, TIED TO STORM
N

TRUSS BEARING 26' - 0"


3-COAT CEMENT PLASTER OVER METAL LATH, PAINTED

BRICK VENEER (B-1)

SECOND FLOOR 14' - 0"


M M

FIRST FLOOR 0' - 0"


PAINTED HM DOOR AND FRAME
L

EXTERIOR GRADE WATER FOUNTAIN


L

1
K

NORTH ELEVATION
1/8" = 1'-0"

2 A3.102

A
J

A.3

B.7

C.3

D
PREFINISHED STANDING SEAM METAL ROOF

E
J

MATERIAL LEGEND
B-1 4" X 8" BRICK MANUFACTURER: CHEROKEE BRICK AND TILE CO COLOR: TBD EXTERIOR PAINT MANUFACTURER: SHERWIN WILLIAMS COLOR: TBD

3 A4.103 ALUMINUM WINDOW SYSTEM

EP-1

TRUSS BEARING 26' - 0"


BRICK VENEER (B-1)

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

SECOND FLOOR 14' - 0"


PREFINISHED HM LOUVER, SEE MECH DWGS
G

MAILBOXES

FIRST FLOOR 0' - 0"

2
E

WEST ELEVATION (ROOF REMOVED FOR CLARITY)


1/8" = 1'-0"

2 A3.102
E

A
PREFINISHED STANDING SEAM METAL ROOF

TRUSS BEARING 26' - 0"


ALUMINUM WINDOW SYSTEM
C C

PREFINISHED HM LOUVER, SEE MECH DWGS

SECOND FLOOR 14' - 0"

BRICK VENEER (B-1) CEMENT PLASTER SOFFIT, PAINTED (EP-1)


B B

FIRST FLOOR 0' - 0"

UNF OSPREY CLUBHOUSE


UNF DRIVE

EXTERIOR ELEVATIONS
A

3
2 1

EAST ELEVATION BALCONY REMOVED FOR CLARIFY)


1/8" = 1'-0"

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3

A2.102

10

11

12

13

14

15

16

17

PRE-ENGINEERED METAL TRUSSES

SECOND FLOOR 14' - 0"

PREFINISHED STANDING SEAM METAL ROOF ON WATERPROOF MEMBRANE OVER PLYWOOD DECKING

PREFINISHED ALUMINUM GUTTER AND DOWNSPOUT SYSTEM - TIED TO STORM

1'-0" 2"

11' - 4" TRUSS BEARING


135 .00

STEEL TUBE, SEE STRUCT DWGS


M

1' - 2 1/2"

SINGLE SOLDIER COURSE FIBER CEMENT BEAM WRAP, PAINTED

1" 11 1/4" 6' - 8"


L

STEEL COLUMN, SEE STRUCT DWGS

SINGLE SOLDIER COURSE

FIBER CEMENT COLUMN WRAP, PAINTED SEALANT

PRECAST CAP SINGLE SOLDIER COURSE 4" 2' - 8" TOP OF PRECAST CAP

BRICK BASE 2' - 0"


J

FIRST FLOOR 0' - 0"

4"

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

BRICK PATTERN DETAIL


3/4" = 1'-0"

COLUMN SECTION
3/4" = 1'-0"

2
F

A2.201

3' - 4"

3' - 4"

10" FIBER CEMENT BEAM WRAP, PAINTED

1' - 8"

10"

6' - 2"

10"

1' - 8"

10"

8"

FIBER CEMENT COLUMN WRAP, PAINTED 2' - 8" TOP OF PRECAST CAP PRECAST CAP
C C

2' - 8"

BRICK BASE

6' - 8"

UNF OSPREY CLUBHOUSE


UNF DRIVE

ELEVATION DETAILS

3
A
11 10 9 8 7 6 5 4 3 2 1

GAME ROOM TRELLIS


1/2" = 1'-0"
A

PROJECT NO:

120063.00
17 16 15 14 13 12

A2.201

10

11

12

13

14

15

16

17

GENERAL NOTES
1. ALL GLASS TO BE TEMPERED.
18' - 7 3/8" 5' - 4"
P

9' - 10 5/8"

3' - 11 1/8"

3' - 9"

3' - 9"

3' - 5 1/4"

3' - 9"

2. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO FABRICATION.
2' - 8"
P

3' - 9"

3' - 8 1/4"

1' - 11 3/4" 21' - 10 5/8" 2' - 8"

TRUSS BEARING 26' - 0"


3' - 8"

3. DIMENSIONS ARE TO CENTERLINE OF MULLION UNLESS NOTED OTHERWISE. 4. MULLIONS TO ALIGN HORIZONTALLY AND VERTICALLY ACROSS THE BUILDING ELEVATIONS. 5. SEE SPECIFICATIONS FOR GLASS PERFORMANCE REQUIREMENTS.

7' - 4" 3' - 6" 3' - 6" 3' - 6" 3' - 6" 3' - 8"

FIRST FLOOR 0' - 0"


3' - 6" 3' - 6" 3' - 6" 3' - 6"

6. THE GENERAL CONTRACTOR SHALL SUBMIT TO THE BUILDING DEPARTMENT THE STRUCTURAL TESTING FOR ALL WINDOWS AND DOORS FOR APPROVAL PRIOR TO INSTALLATION. 7. THE GENERAL CONTRACTOR SHALL SUBMIT TO THE BUILDING DEPARTMENT THE INFILTRATION TESTING FOR ALL WINDOWS AND DOORS FOR APPROVAL PRIOR TO INSTALLATION.

E
SECOND FLOOR 14' - 0"
M

3' - 6"

3' - 6"

26' - 0"

3' - 6"

26' - 0"

22' - 0"

22' - 0"

26' - 0"

3' - 6"

3' - 6"

3' - 6"

3' - 6"

GLAZING INFILL LEGEND


5' - 4" 7' - 6" 2' - 0 1/4" 3' - 3 3/4"

G1 - INSULATED TINTED GLASS


3' - 8" 7' - 4"

4' - 0"

4' - 0"

4' - 0"

4' - 1 1/4"

4' - 1 1/4"

4' - 1 1/4"

4' - 1 1/4"

11 5/8"

11 11/16"

6' - 0" CLR

11 11/16"

11 5/8"

11' - 6 3/8"

7' - 1"

3' - 8 1/4"

3' - 11 1/4" 11 1/4"

6' - 0" CLR 19' - 4"

11 1/4"

3' - 10" 2' - 6 5/8"

FIRST FLOOR 0' - 0"


3' - 0" CLR

3' - 8"

G2 - INSULATED, TINTED SPANDREL GLASS

FIRST FLOOR 0' - 0"

G3 - COMPOSITE METAL PANEL

D
10' - 1" 3' - 3 3/4" 3' - 10"

G4 - 1/4" CLEAR TEMPERED VISION GLASS

2' - 11 1/4"

22' - 0" 2' - 8 1/4"


J

22' - 0" 4' - 0" 4' - 0" 3' - 3 3/4" 3' - 10 3/4" 4' - 0" 6' - 2 1/2" 4' - 0" 3' - 10 3/4" 3' - 10 3/4"

14' - 0" 6' - 2 1/2" 3' - 10 3/4" EQ

14' - 0" 6' - 2 1/2" EQ

SECOND FLOOR 14' - 0"

G5 - 1/4" CLEAR TEMPERED GLASS WITH FROSTED FILM

4' - 0"

4' - 0"

4' - 0"

4' - 0"

4' - 0"

4' - 0"

14' - 0"

10' - 0"

10' - 0"

10' - 0"

10' - 0"

4' - 0"

2' - 0"

FIRST FLOOR 0' - 0"


3' - 0" CLR 6' - 0" CLR 3' - 0" CLR

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

4' - 1 1/4"

4' - 1 1/4"

4' - 1 1/4"

4' - 1 1/4"

4' - 1 1/4"

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

G
G

L
G

5' - 5" 1' - 7" 3' - 10" EQ

7' - 6" EQ

4' - 11" 3' - 9" 1' - 2" 2' - 5"

6' - 2" 3' - 9" 7' - 6" 5' - 6" 2' - 4" 3' - 9" 3' - 9" 1' - 9" 3' - 9" 1' - 9" 1' - 9" 5' - 5" 3' - 8"
F

SECOND FLOOR 14' - 0"


4' - 0" 4' - 0" 4' - 0"
F

TRUSS BEARING 26' - 0"


4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0"

14' - 0"

4' - 0"

2' - 0"

10' - 0"

10' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

4' - 1 1/4"

FIRST FLOOR 0' - 0"

8' - 0"

10' - 0"

SEE BUILDING ELEVATIONS FOR SPANDREL LOCATIONS


E

SECOND FLOOR 14' - 0"

8' - 1"
C

6' - 5" 2' - 5" 4' - 0" 3' - 10 3/4" 4' - 0"

22' - 0" 6' - 2 1/2" 4' - 0" 3' - 10 3/4"

2' - 2"

4' - 0"

4' - 1"

TRUSS BEARING 26' - 0"


2 4' - 0" A2.402

3 A2.402 9' - 0" 5' - 9" 5' - 0" 3' - 3"

4' - 0"

4' - 0"

4' - 0"

3' - 10"

G4 2' - 8"

3' - 0"

5' - 4" 2' - 8"


B

8' - 0"

G4

5 A2.402 A2.402 7' - 2" 4

UNF OSPREY CLUBHOUSE


UNF DRIVE

10' - 0"

10' - 0"

4' - 1 1/4"

4' - 1 1/4"

10' - 0"

4' - 1 1/4"

6' - 0" CLR


A

SECOND FLOOR 14' - 0"

6 A2.402 7 A2.402

3' - 0" CLR

FIRST FLOOR 0' - 0"

10" 2' - 0"

3' - 4"

SECOND FLOOR 14' - 0"

GLAZING ELEVATIONS
A

AA

BB

CC

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

A2.301

10

11

12

13

14

15

16

17

1 A2.302 6' - 0" 2' - 0" 4' - 0" 2' - 0"

2' - 0"

2 2' - 0" 5' - 4" A2.302 6' - 0" 2' - 0"

3 A2.302 10' - 8"

10' - 0"

8' - 0"

9' - 4"

8' - 0"

2' - 0"

FIRST FLOOR 0' - 0"

FIRST FLOOR 0' - 0"

FIRST FLOOR 0' - 0"

FIRST FLOOR 0' - 0"

SECOND FLOOR 14' - 0"

L1

L2

L3

L4

L5

7" WEATHER BARRIER 6" RIGID INSULATION BOARD 8" CMU WALL BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN CONT PT WOOD BLOCKING 8" CMU WALL GLASS, SEE GLAZING ELEVATION FOR TYPE SEALANT AND BACKER ROD CONT. P.T. WOOD BLOCKING SLOPE RO ALUMINUM LOUVER, SEE MECH DWGS WEATHER BARRIER MEMBRANE
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

WEATHER BARRIER MEMBRANE ALUMINUM LOUVER, SEE MECH DWGS

CONT. THRUWALL METAL FLASHING MORTAR MESH

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

WEEP VENTS @ 24" OC


G G

GLASS, SEE GLAZING ELEVATION FOR TYPE CONTINUOUS P.T. WOOD BLOCKING RO SILL BELOW, WHERE OCCURS WEATHER BARRIER SEALANT AND BACKER ROD
F

3/4"

ALUMINUM LOUVER

SELF-ADHERED MEMBRANE FLASHING WEATHER BARRIER SEALANT AND BACKER ROD BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN RIGID INSULATION BOARD

8" CMU WALL

6"

RO

BRICK TIE RIGID INSULATION BOARD

HEADER DETAIL
3" = 1'-0"

JAMB DETAIL
3" = 1'-0"

SILL DETAIL
3" = 1'-0"
E

UNF OSPREY CLUBHOUSE


UNF DRIVE

LOUVER ELEVATIONS & DETAILS


A A PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

A2.302

10

11

12

13

14

15

16

17

7" WEATHER BARRIER RIGID INSULATION BOARD


P

RIGID INSULATION BOARD 8" CMU WALL


P

WEATHER BARRIER

BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN

2 1/2" METAL STUD FRAMING

5/8" GYPSUM BOARD

CONT. THRUWALL METAL FLASHING MORTAR MESH

5/8" GYPSUM BOARD

WEEP VENTS @ 24" OC

CONTINUOUS P.T. WOOD BLOCKING

LIGHT GAUGE TRUSS, SEE STRUCT DWGS CEMENT PLASTER SOFFIT, PAINTED SEALANT
M

CORNER BEAD

RO

STEEL BEAM, SEE STRUCT DWGS HAT CHANNELS SOFFIT VENT, AS SHOWN ON CEILING PLAN 3-COAT CEMENT PLASTER OVER PAPER-BACKED METAL LATH SEALANT MECHANICAL ROLLER SHADE WITH BLACKOUT FABRIC & SIDE RAILS GLASS, SEE GLAZING ELEVATION FOR TYPE 6" SEALANT AND BACKER ROD

CORNER BEAD

ALUMINUM WINDOW SYSTEM, SEE ELEVATION GLASS, SEE GLAZING ELEVATION FOR TYPE 6 13/16" CEILING, REFER TO CEILING PLAN FOR TYPE AND ELEVATION

BRICK ANGLE, PAINTED SEALANT AND BACKER ROD

ALUMINUM WINDOW SYSTEM

ALUMINUM WINDOW SYSTEM

6"

7 1/2"

1
K

WIN-ALUM HEAD @ ROOF


3" = 1'-0"

WIN-ALUM HEAD @ SOFFIT


3" = 1'-0"

HEADER DETAIL
3" = 1'-0"

CORNER BEAD BACKER ROD AND SEALANT

8" CMU WALL

5/8" GYPSUM BOARD MECHANICAL ROLLER SHADE WITH BLACKOUT FABRIC & SIDE RAILS (AT MULTIPURPOSE ROOM) 7 1/2"
J

CONT. P.T. WOOD BLOCKING ALUMINUM WINDOW WEATHER BARRIER MEMBRANE


J

6 3/4"

ALUMINUM WINDOW, SEE ELEVATION

GLASS, SEE GLAZING ELEVATION FOR TYPE

ALUM WINDOW SYSTEM 2 1/2"


H

6" WINDOW WALL

STEEL COLUMN, SEE STRUCT DWGS

7 1/2" CURTAINWALL /

GLASS, SEE GLAZING ELEVATION FOR TYPE SILL BELOW, WHERE OCCURS SELF-ADHERED MEMBRANE FLASHING WEATHER BARRIER
G

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

6"

NO
GLASS, SEE GLAZING ELEVATION FOR TYPE GLASS, SEE GLAZING ELEVATION FOR TYPE

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

6"

6"

SEALANT

SEALANT AND BACKER ROD RO

BREAK METAL INFILL, FINISH TO MATCH WINDOW SILL BELOW

BRICK VENEER W/ AIR SPACE, SEE ELEVATION FOR SIZES AND PATTERN RIGID INSULATION BOARD

4
E

WIN-ALUM JAMB @ COL


3" = 1'-0"

HORIZONTAL MULLION DETAIL


3" = 1'-0"

JAMB DETAIL
3" = 1'-0"

6"

6" ALUMINUM WINDOW

GLASS, SEE GLAZING ELEVATION FOR TYPE SEALANT AND BACKER ROD
D

WEATHER BARRIER MEMBRANE CONT. P.T. WOOD BLOCKING STEEL COLUMN (WHERE OCCURS), SEE STRUCT DWGS INTERIOR CURTAINWALL CLIP ON VERTICAL MULLION 2" GLASS, SEE GLAZING ELEVATION FOR TYPE 6" AT WINDOW WALL 7.5" AT CURTAINWALL
D

SLOPE SEALANT AND BACKER ROD CORNER BEAD RO

ALUMINUM WINDOW SYSTEM SEALANT AND BACKER ROD COMPRESSIBLE FILLER EXTERIOR WALKWAY, REFER TO LANDSCAPE DWGS SCHEDULED FINISH
C

5/8" GYPSUM BOARD 7 1/2"


C

3/4"

WEATHER BARRIER 8" CMU WALL RIGID INSULATION BOARD GLASS, SEE GLAZING ELEVATION FOR TYPE VERTICAL MULLION 2 1/2"

EXTERIOR CONCRETE SLAB

VAPOR BARRIER

UNF OSPREY CLUBHOUSE


UNF DRIVE

GLAZING DETAILS

7
A
1

WIN-ALUM SILL@ BRICK


3" = 1'-0"

8
7 6 5 4 3

VERTICAL MULLION DETAIL


3" = 1'-0"

9
12 11 10 9

SILL DETAIL
3" = 1'-0"
A

PROJECT NO:

120063.00
17 16 15 14 13 8 2

A2.401

10

11

12

13

14

15

16

17

METAL STUD FRAMING W/ BATT INSULATION

METAL STUD FRAMING W/ BATT INSULATION

5/8" GYPSUM BOARD


N

5/8" GYPSUM BOARD


N

SEALANT, BOTH SIDES LIGHT GAUGE TRUSS, SEE STRUCT DWGS CEMENT PLASTER SOFFIT, PAINTED SEALANT ALUMINUM WINDOW SYSTEM, SEE ELEVATION GLASS, SEE GLAZING ELEVATION FOR TYPE 1' - 2" STEEL BEAM, SEE STRUCT DWGS WOOD BLOCKING

HOLLOW METAL WINDOW FRAME, PAINTED

ALUMINUM WINDOW FRAME

2
L

HEAD DETAIL
3" = 1'-0"

HEAD DETAIL
3" = 1'-0"

5/8" GYPSUM BOARD

1
K

HEAD DETAIL
3" = 1'-0" 5/8" GYPSUM BOARD METAL STUD FRAMING W/ BATT INSULATION METAL STUD FRAMING W/ BATT INSULATION
K

6" METAL INFILL FRAMING AT ROOF WEATHER BARRIER BATT INSULATION


J J

3-COAT CEMENT PLASTER OVER PAPER-BACKED METAL LATH, PAINTED

5/8" GYPSUM BOARD CONTINUOUS PT WOOD BLOCKING

SEALANT, BOTH SIDES HOLLOW METAL WINDOW FRAME, PAINTED

WOOD BLOCKING ALUMINUM WINDOW FRAME

CONT FLASHING AT OPENING


H

4
SEALANT AND BACKER ROD ALUMINUM WINDOW SYSTEM

JAMB DETAIL
3" = 1'-0"

JAMB DETAIL
3" = 1'-0"

ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE PROPERTY OF BAKER BARRIOS ARCHITECTS, INC. AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF BAKER BARRIOS ARCHITECTS, INC. WARNING: REPRODUCTION HEREOF IS A CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506 UNAUTHORIZED DISCLOSURE MAY CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION OF 1.C.24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR BE THE SUBJECT OF PENDING PATENT APPLICATION.

NO

DATE 04.15.13

REVISION/ SUBMISSION ISSUE FOR PERMIT

DW

CK

8
G

HEADER DETAIL
3" = 1'-0" HOLLOW METAL WINDOW FRAME, PAINTED
G

ALUMINUM WINDOW FRAME

WOOD BLOCKING

ALUMINUM WINDOW SYSTEM


F

SEALANT, BOTH SIDES SEALANT AND BACKER ROD 5/8" GYPSUM BOARD CONT FLASHING AT OPENING 3-COAT CEMENT PLASTER OVER PAPER-BACKED METAL LATH, PAINTED CONTINUOUS PT WOOD BLOCKING 6" METAL INFILL FRAMING AT ROOF BATT INSULATION WEATHER BARRIER 5/8" GYPSUM BOARD METAL STUD FRAMING W/ BATT INSULATION METAL STUD FRAMING W/ BATT INSULATION 5/8" GYPSUM BOARD

SILL DETAIL
3" = 1'-0"

SILL DETAIL
3" = 1'-0"

9
D

SILL DETAIL
3" = 1'-0"
D

UNF OSPREY CLUBHOUSE


UNF DRIVE

GLAZING DETAILS
A A

PROJECT NO:

120063.00
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

A2.402

Anda mungkin juga menyukai