Backfillcontainingrocksoraggregateshouldnotbeusedtobackfillanypiping ELECTRICALCONDUITSUPPORTREQUIREMENTS2005NEC CONDUITTYPE IntermediateMetal(IMC) NECSection34230(A)(B)&Table 344.30(B)(2) CONDUITSIZE MAX.DISTBTWNSUPPORTS FASTENINGSUPPORTDISTANCEFROMOUTLETBOX, JUNCTIONBOX,CABINET,ORFITTING 3feetCanbeincreasedto5feetwherestructuralmembersdonot readilypermitfasteningswithin3feet
RigidMetal(RMC) NECTable344.30(B)(2)
10feet 12feet 14feet 16feet 20feet 3feet 5feet 6feet 7feet 8feet 10feet
3feetCanbeincreasedto5feetwherestructuralmembers donotreadilypermitfasteningswithin3feet
Allsized3feet
3feet
CONDUITSIZE
MAX.DISTBTWNSUPPORTS WherepermittedbyNECshallbe securedbystaples,straps,or similarfittingssodesignedand installedasnottodamagethe cable.Secureatintervalsnot exceeding4feet.Cablesrun throughholesinwoodormetal joists,raftersorstudsshallbe consideredtobesupported& secured.Thecableshallclosely followthesurfaceofthebuilding finishorofrunningboards. 3feet 4feet 6feetHorizontalRun Seeexceptionforunsupported cables.
WATERLINEBURIALREQUIREMENTS2005UniformPlumbingCode v All water service yard piping shall be at least twelve (12) inches below the average local frost depth. The frost depth in Humboldt County is twentyfour (24) inches, thereforewaterlinesshallbeburiedatadepthofthirtysix(36)inches. v Thewaterlineshallbeapprovedforpotablewateruse.Copper,PEX,orCPVCwaterlinemaybeusedwithinabuildingorstructure.PVCwaterlinemaybeusedupto thebuildingorstructurefoundationandtransitiontoapprovedpipe.(Note:PEXwaterlinemaybeusedwithinabuildingorstructure.PEXALPEXmaybeusedwithina buildingorstructure.PEALPEshallbeusedinsideabuildingorstructureforcoldwaterlineonly. v Waterpipingshallnotberanorlaidinthesametrenchasthesewerlineunlessallrequirementsof2003UPCSection720.0aremet. v Waterpipingcanberaninthesametrenchastheelectricallinewiththewaterpipingbelowtheelectricallineswithatwelve(12)inchearthseparation. v Waterlinecrossingsewershallhaveaminimumof12earthseparationandthewaterlineshallbesleevedwitha10footpipeinstalledwith5feetoneachsideofthe crossover. v Pipesshallbeproperlybeddedwithsand.Backfillcontainingrocksoraggregateshouldnotbeusedtobackfillanypiping. WATERLINESUPPORTREQUIREMENTS(2005UPCTABLE32) TYPEOFPIPING Coppertube&pipe CPVC PEX PEXALPEX PEALPE PVC PIPESIZE to1 2&larger to1 1&larger Allsizes Allsizes AllsizesOnlypermittedforcoldwater insidethefoundationwallofanybuilding Nopermittedinsidethefoundationwallof anybuilding. HORIZONTAL 6feet 10feet 3feet 4feet 32 98 98 MAX.DISTANCEBETWEENSUPPORTS VERTICAL Eachfloornottoexceed10 Base&eachfloor.Providemidstory guides Base&eachfloor.Providemidstory guides Base&eachfloor.Providemidstory guides Base&eachfloor.Providemidstory guides
SEWERLINESBURIALREQUIREMENTS2005Uniform PlumbingCode v Buildingsewerlinesshallruninpracticalalignmentandatauniformslopeofnotlessthanonefourth(1/4)ofaninchperfoottowardthepointofdisposal.Buildingsewer pipingshallbelaidonafirmbedthroughoutitsentirelength. v Cleanoutsshallbeplacedinsidethebuildingneartheconnectionbetweenthebuildingdrainandthebuildingsewerorinstalledoutsidethebuildingatthelowerendofthe buildingdrainandextendtograde.Cleanoutsshallalsobeplacedatintervalsnottoexceedonehundred(100)feet. v Buildingsewerlinesshallnotbeplacedinthesametrenchaselectricalandwaterlines. v Changesindirectionofdrainagepipesshallbemadewithapprovedfittings45wyefitting.Recommendusinglongsweep45. UPCSection706. v Pipesshallbeproperlybeddedwithsand.Backfillcontainingrocksoraggregateshouldnotbeusedtobackfillanypiping. SEWERLINESUPPORTREQUIREMENTS(2006UPCTable32) TYPEOF PIPE Cast MAX.DISTANCEBETWEENSUPPORTSHORIZONTAL TypeofJoint(lead&Oakum)5feetexceptmaybe10feetwhere 10feetlengthsareinstalled.Mustsupportateachhorizontalbranch connection. TypeofJoint(CompressionGasket)Everyotherjointunlessover 4feetthensupportedwithin18ofeachjoint.Supportateach horizontalbranchconnection. 4feetandatendofbranchesorchangesindirections MAX.DISTANCEBETWEENSUPPORTSVERTICAL Base&eachfloornottoexceed15feet.
Cast
Base&eachfloornottoexceed15.
ABSDWV
Baseandeachfloor.Providemidstoryguides.Provideforexpansionevery30
FUELGASPIPINGBURIALREQUIREMENTS2006UniformPlumbingCode v No gas piping shall be installed in or on the ground under any building or structure and all exposed gas piping shall be kept at least six (6) inches above grade and structures. v Allhorizontalmetallicpipingshallhaveatleasttwelve(12)inchesofearthcover.Plasticgaspipingshallhaveatleasteighteen(18)inchesofearthcover. v Allservicelinesshallbelaidoncleancompactedsoilandshallbecoveredwithalayerofsandbeforebackfilling.Allrocksoranysubstanceswhichwouldpuncturelines shallberemoved. v Plasticpipeshallhaveatracerwire(Min.AWG14)shallbeburied(corrosionresistant)withplasticpipeforlocatingpurposes.Oneendshallbebroughtabovegroundata buildingwallorriser.2003UniformMechanicalCode,Section1311.1.7(c) v Pipesshallbeproperlybeddedwithsand.Backfillcontainingrocksoraggregateshouldnotbeusedtobackfillanypiping. FUELGASPIPINGSUPPORTREQUIREMENTS(2006UPCTables32&123) TYPEOFPIPE Steel,brass,&tinnedcopper SIZEOFGASPIPING or1 1orLarger 5/8or 7/8or1 HORIZONTAL 6feet 8feet 10feet 4feet 6feet 8feet MAX.DISTANCEBETWEENSUPPORTS VERTICAL Everyfloorlevel
TubingSmoothWall
Everyfloorlevel
BuildingDepartmentFolder/HandoutFolder/UtilityBurial&SupportRequirements52008