Anda di halaman 1dari 4

ZTE

ZHONGXING TELECOM PAKISTAN (Pvt.) LTD.

ZTE

GSUR (BLUE) CONECTORS CABLE CONECTIONS


XJ1 CONECTOR
XJ1 connector have two ports, i.e. UPPER PLUG & LOWER PLUG. But we use only LOWER PLUG.

LOWER PLUG
GND1 TXD1 RXD1 GND2 TXD2 RXD2

{Laptop Ports for Software}

{Ports connected to Rectifier for Alarms}

6{GND2} -----------------------------5{GND1}

GSUR PORTS

7{TXD2} -----------------------------2{RXD1} 8{RXD2} -----------------------------3{TXD1}

ALARMS DETAIL

04 Alarms Are Connected Through XJ1 PLUG Of GSUR to Rectifier.

1. AC Main Failure. 2. SMR Failure/ Faulty. 3. AC Phase Lost. 4. Low Battery.

MUHAMMMAD AHSAN NADEEM

0313-4447274, 0312-4552355

MANAGED SERVICES ZTE LAHORE mahsan.nadeem@gmail.com

Rectifier PORTS

ZTE

ZHONGXING TELECOM PAKISTAN (Pvt.) LTD.

ZTE

GSUR (BLUE) CONECTORS CABLE CONECTIONS


XJ2 CONECTOR
XJ2 connector have two ports, i.e. UPPER PORT & LOWER PORT. This Port is Directly Connected to BTS Alarm Port.

LOWER PLUG 06 Alarm are Connected to this Plug


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Port No. 1&2 3&4 7&8 9 & 10 13 & 14 15 & 16

Connected Alarm Temperature Alarm DG Fail to start Door Alarm Smoke Alarm DG in Operation Low Fuel Tank

Cable Colour White / Blue White / Orange White / Green White / Brown Red / Blue Red / Orange

UPPER PLUG 04 Alarm are Connected to this Plug


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Port No. 3&4 5&6 9 & 10 11 & 12

Connected Alarm Low Battery Alarm Main failer Alarm Air Conditioner Alarm SMR Failure Alarm

Cable Colour Black / Blue Black / Orange Black / Green Black / Brown

MUHAMMMAD AHSAN NADEEM

0313-4447274, 0312-4552355

MANAGED SERVICES ZTE LAHORE mahsan.nadeem@gmail.com

ZTE

ZHONGXING TELECOM PAKISTAN (Pvt.) LTD.

ZTE

GSUR (BLUE) CONECTORS CABLE CONECTIONS


XJ3 CONECTOR

XJ3 connector have two ports, i.e. UPPER PLUG & LOWER PLUG. But we use only LOWER PLUG.

LOWER PLUG
{N o t u s e d }
{Not used}

5
+12

6
-12

7
AI1

8
AI2

10

11

12

13

14

15

16

+12 GND AI3 AI4 +12 GND AI5 AI6

Cables Connection Detail for XJ3 Lower Plug is as Follows:

Port Detail
+ 12 V - 12 V GND AI 1 AI 2 AI 3 AI 4 AI 5 AI 6

Port No.
5, 9,13 06 10, 14 07 08 11 12 15 NOT USE

Alarm Cable
AC1, AC2, Low Fuel, Temp., Door , DG AC1, AC2 AC1, AC2 AC1 From Transducer Out AC2 From Transducer Out DG in Operation From ATS Low Fuel Alarm From Fuel Sensor Door Alarm From Door Sensor NOT USED

MUHAMMMAD AHSAN NADEEM

0313-4447274, 0312-4552355

MANAGED SERVICES ZTE LAHORE mahsan.nadeem@gmail.com

ZTE

ZHONGXING TELECOM PAKISTAN (Pvt.) LTD.

ZTE

GSUR (BLUE) CONECTORS CABLE CONECTIONS


X35 CONECTOR

X35 connector has two ports, i.e. UPPER PLUG & LOWER PLUG.

LOWER PLUG 01 Alarm (SMOKE) is Connected to this Plug


1 PIN No. 01 02 2 3 CABLE DETAIL Out Put Fro Smoke Sensor +24 V From Smoke Sensor Smoke Sensor Pins (1, 3) 4

UPPER PLUG 01 Alarm (TEMPERATURE) is Connected to this Plug


1 PIN No. 03 2 3 CABLE DETAIL Temperature Input From Temp. Sensor Temp. (T1), +V=12v with XJ3 4

MUHAMMMAD AHSAN NADEEM

0313-4447274, 0312-4552355

MANAGED SERVICES ZTE LAHORE mahsan.nadeem@gmail.com