DIMENSIONS (mm) ITEM INSTALLED ON NR DESCRIPTION L

UNIT 230100 -TOTAL WELL HEAD UNIT SATURATION EXTINGUISHING X X X X CP CP CP CP X CP 231 231 231 231 231 231 231 231 233 233 01 02 03 04 01 02 03 04 01 01 X-233 X-231 -01 X-231 -02 X-231 -03 X-231 -04 1 1 1 1 1 1 1 1 1 1 Total saturation extinguishing system package (inergen) Total saturation extinguishing system package (inergen) Total saturation extinguishing system package (inergen) Total saturation extinguishing system package (inergen) Total saturation extinguishing system Control Panel Total saturation extinguishing system Control Panel Total saturation extinguishing system Control Panel Total saturation extinguishing system Control Panel CO2 Extinguishing Package CO2 extinguishing system package's control Panel 1100 700 2200 1800 2700 2300 1500 1000 1000 1000 1000 3000 3000 3000 3000

WEIGHT (t) MATERIAL Empty Oper.

CAPACITY

TEMPERATURE (C) Prog. Oper. Prog.

PRESSURE (bar g) Oper.

W/D

ABS. POWER (kW)

PED CATEGORY (to be confirmed by vendor)

NOTES

for survival module/ HVAC/ emerg.gen./ diesel pump/ elec. & instr. Rooms

0.40

0.40

UNIT 240 - UNINTERRUPTABLE POWER SUPPLY SYSTEM 1 UNIT 250- CATHODIC PROTECTION AND MONITORING 1 UNIT 260 - TELECOMMUNICATIONS IC IC IC IC IC IC IC IC IC 261 261 261 261 261 261 261 261 262 01 02 03 04 05 06 07 IC-261 IC-261 IC-261 IC-261 IC-261 IC-261 IC-261 1 1 1 1 1 1 1 1 1 Telecom cabinet VHF marine radio system VHF aeronautical radio system UHF marine radio system Microwave system GSM system PABX system+CCTV Patch Panel Tones Generation 800 800 2100 Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON Cathodic Protection Cabinet located on electrical room Batteries Ni-Cd

UNIT 270 - CONTROL SYSTEM CP 271 1 1 UNIT 280 - ESD/FIRE & GAS SYSTEM CP 281 1 ESD / F&G DCS Integrated with Vega A ;later defined

UNIT 290 - ACCELEROMETERS/SUBSIDENCE CONTROL IM IM IM IM IM IM IM CP 291 291 291 291 291 291 291 292 01 02 03 04 05 06 07 1 1 1 1 1 1 1 Monitoring Systems Monitoring Systems Monitoring Systems Monitoring Systems Monitoring Systems Monitoring Systems Monitoring Systems Monitoring Systems' Control Panel Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON Supplied by EDISON

UNIT 300 - HELIDECK SYSTEM D X X X X X X 302 301 302 302 303 303 303 A B A B C 1 1 1 1 1 1 1 Helideck drain tank Fire fighting system powder skid powder skid foam monitor foam monitor foam monitor 1200 1100 1600 0.36 1.72 1.36 m 3 5--60 5--35 atm atm IBC type (SNYDER INDUSTRIEES Mfr.or equivalent) including premixer and foam monitor

UNIT 310 - NITROGEN SYSTEM X X X 312 313 314 1 1 1 Membranes N2 Generator Pckg Nitrogen Storage Pckg N2 Compressor Pckg 1300 400 1400 0.50 0.50 3 Nm 3/h 60 Nm 3 3 Nm 3/h 5 / 60 5 / 60 40 40 40 7.0 200.0 200.0 3.5 190.0 190.0 Design T by Nitrogen system Supplier for iblanketing of diluent tank, diesel tank, closed drain tank. according to Vendors catalogues Data estimated

UNIT 320- VENT AND BLOWDOWN D V FL CP ME ME LT 321 322 323 324 324 325 326 01 1 1 1 1 1 1 1 Vent K. O.drum Cold vent Pilot Ignition flare control panel LPG-Bottles unit Electric Heater Flame Arrester CS & SS 3840 Kg/h -22/ 400 amb 3.5 atm 6.00 18000 914 1850 1.20 1.30 CS 1.4 m 3 -22 / +65 amb 3.5 atm Outside Diameter With ignition panel