Anda di halaman 1dari 20

CWO COVERSHEET

CWO Type
CWO Request Ref.
Facility ID
New ST TLN
Reason for Issue
Action Required
CWO Imp Due Date

:
:
:
:
:
:
:

Rev

Comp Date

13-Apr-08

77559 rev 0

GSM-RBS
TFR 01-08040036
BSC/105-00-000-RBS/607-00-000
30542-001
New Route
NEW INSTALL, 2Mbps
01/January/00

NI and last Rev number

GSM C&I PH7

Total number of pages


Allocation
Allocation
Table
Table
System
System
Design
Design
Card
Card
Miscellaneous
Miscellaneous

:
:
:
:

DETAILS OF ACTIVITY
To activate initial 1x2Mbps circuit between BSC/105 and RBS/607 intended to BTS site ZQSA980 with Facility ID: BSC/105-RBS/607 30N01 due to new 2G sites. Part of
part of GSM C & I Phase 7 Project for New 2G Site Project.

Misc Attachment Details

Facility Assignment Sheets for Reference.

TO BE COMPLETED BY NETWORK INTEGRATION / NNCC


DEPARTMENT
DATE CROSS-CONNECTED
INSTALLED/TESTED
DATE CWO IMPLEMENTED
DATE RETURNED TO CWOD

:
:
:
:
:

REMARKS :

Send feedback @ fax: (01) 452 9610


TLN ISSUER :
NI CWO COORDINATOR / NNCC

Or Contact Syed Muhammad Ali @ Tel: 452 8790


NETWORK ADMINISTRATION / CWO DESIGN

19
1
2
16

ALLOCATION TABLE

FACILITY ID : BSC/105-RBS/607 30Nxx


RIYADH 105 (Makkah Rd.)

QASSIM 607 (Midhnab)

GSM TERMINATIONS

GSM TERMINATIONS
TIE CABLE INFO.:

BSC NODE
GSM SITE
30Nxx

01

BSC/105

ADMU DDF

MSC/BSC

HUAWEI

EQUIPMENT

GSM DDF

FIRST FLOOR

SECOND FLOOR

(2 Mbps)

JVC/BSC#

PORT

BayLoc/Pnl/Vert/Conn

Bay/Pnl/Vert/Conn

Flr/Bay Loc/Pnl/Blk/Conn

Flr/Bay/Pnl/Blk/Conn

Flr/RowBay/Pnl/Blk/Conn

GR17H2

329

01.GR17H2.HU01/1/20,21/9

01.GR17H2.HUD05/07/04-05/02

01.GR17H2.HUD01/05/04-05/04

100A.06/02/03/12

02/100B.08/07/15/58

NI- 77559/0
TFR# 01-08040036
File: J:/CWO DESIGN\NEW CWOs\gsm\gsme7\bsc\riyadh(105)\193534270.xls.ms_office
RN: 80270
Circuit Type : GSM-RBS
Part of GSM C I Project

DDF Pos.
NEW TLN

30542-001

GSM DSX

NEXT FACILITY ID

NEXT FACILITY ID

(2 Mbps)

Long Distance Network

Junction Ring

Flr/Bay Loc/ Pnl.Blk/ Row/Pin

FR/Pnl/PR

Riyadh 10500000/2MU IS02 - 58

Qa03-2 (STM-16 Ring) VC4-02 - 16

G/205.05/01.01/08/7-12

tbd

SDH NODE

NEXT FACILITY

GSM
CELL SITES

QASSIM 607

Digital Microwave

ZQSA980-M001

Revision
00 :13-Apr-08

LONG DISTANCE NETWORK


SYSTEM DESIGN CARD

2 Mbit/s Facility ID:

BSC/105-RBS/607 30N01

Circuit Type

GSM-RBS

NEW TLN : 30542-001

SITE : 105 RIYADH


GSM TERMINATIONS:
NEW TLN

GSM SITE

30542-001
BSC/105

MSC/BSC

HUAWEI

JVC/BSC#

PORT

BayLoc/Pnl/Vert/Conn

Bay/Pnl/Vert/Conn

GR17H2

329

01.GR17H2.HU01/1/20,21/9

EQUIPMENT

01.GR17H2.HUD05/07/04-05/02

GSM DDF

TS/TRIB

X-CONN INFO

METRO ADMU

TIE CABLE INFO:


FIRST FLOOR

SECOND FLOOR

Flr/Bay Loc/Pnl/Blk/Conn

Flr/Bay/Pnl/Blk/Conn

01.GR17H2.HUD01/05/04-05/04

100A.06/02/03/12

SDH TRANSMISSION FACILITY :


METRO ADMU DDF(2Mbps)

SDH NODE

Flr/RowBay/Pnl/Blk/Conn
02/100B.08/07/15/58

X-CONN INFO

Flr/BayLoc/Pnl
105 RYAD/2MU

6.58

CC33.361

02/100B.09P03

CC36.112

LambdaUnite MSS

SDH NODE

LambdaUnite MSS DDF LINK

105 RYAD/1LU

To MESH NETWORK

STM-64 Link Assignment (LINE/AU4 SLOT)

STM-64 ODF (155Mbps)

WORKING

PROTECTION

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

STM64 (W): LS1/CORE1/19

STM64 (P): LS2/CORE2/19

via optical cable

METRO ADMU DDF(2Mbps)

SDH TRANSMISSON FACILITY:


STM-64 ODF (155Mbps)

STM-64 Link Assignment (LINE/SLOT/PORT/AU4 SLOT)

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

WORKING

PROTECTION

Flr/BayLoc/Pnl

via optical cable

STM64 (W): SLOT 1/PORT 2/19

STM64 (P): SLOT 2/PORT 2/19

02/100A.09/P02

Flr/BayLoc/Pnl/Conn

SDH NODE

LambdaUnite MSS
Flr/BayLoc/Pnl

WORKING

PROTECTION

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

107 RYAD/2LU

03.128.06/P02

STM64 (W): SLOT 1/PORT 1/27

STM64 (P): SLOT 2/PORT 1/27

via optical cable

X-CONN INFO

TS/TRIB

SDH NODE

CC15.153

7.15

107 RYAD/1MU

SITE: 107 RIYADH


SDH TRANSMISSON FACILITY:
LambdaUnite MSS DDF LINK
Flr/BayLoc/Pnl/Conn
To MESH NETWORK

STM-64 Link Assignment (LINE/SLOT/PORT/AU4 SLOT)

STM-64 ODF (155Mbps)

SDH TRANSMISSON FACILITY:


X-CONN INFO

METRO ADMU

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

STM-64 ODF (155Mbps)

WORKING

PROTECTION

via optical cable

STM64 (W): LS1/CORE1/27

STM-64 Link Assignment (LINE/AU4 SLOT)


STM64 (P): LS2/CORE2/27

CC24.112

03.128.06/P03

HUAWEI

Flr/BayLoc/Pnl

Flr/RowBay/Pnl/Blk/Conn
03/129.08/02/04/15

SDH TRANSMISSION FACILITY:


OSN3500 DDF(2Mbps)

SDH NODE

Board_slot/ Trib

OSN3500

HUAWEI

STM-64 Link Assignment

ODF ( SL64 OSN3500 )

T.S

Flr/BayLoc/Pnl

X-CONN INFO

CARD_TYPE/SLOT/PORT/VC12

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

107 RYAD/05HD

PQ1_3/ 23

23

03.109.01/P01

3.6.3

SEP1_15.5/60

03.117.04/P02A/005 (e)

SDH NODE

TS/TRIB

X-CONN INFO

METRO ADMU

X-CONN INFO

107 RYAD/3MU

3.11

CC16.363

03.106.02/P03

CC21.112

SDH NODE

LambdaUnite MSS DDF LINK

107 RYAD/1LU

To MESH NETWORK

Flr/Bay Loc/Panel/Blk/Row(Tx-Rx)/Port
03/117.04/03/06/04-03/07

SDH TRANSMISSION FACILITY :


ADMU DDF(155Mbps)
Flr/RowBay/Pnl/Conn
03.105.01/07/0013ac

Flr/BayLoc/Pnl

STM-64 Link Assignment (LINE/AU4 SLOT)

STM-64 ODF (155Mbps)

WORKING

PROTECTION

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

STM64 (W): LS1/CORE1/20

STM64 (P): LS2/CORE2/20

via optical cable

ADMU DDF(155Mbps)

SDH TRANSMISSON FACILITY:


STM-64 ODF (155Mbps)

STM-64 Link Assignment (LINE/SLOT/PORT/AU4 SLOT)

LambdaUnite MSS

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

WORKING

PROTECTION

Flr/BayLoc/Pnl

via optical cable

STM64 (W): SLOT 1/PORT 2/20

STM64 (P): SLOT 3/PORT 1/20

03.106.02/P02

Flr/BayLoc/Pnl/Conn

SDH NODE

LambdaUnite MSS
Flr/BayLoc/Pnl

WORKING

PROTECTION

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

601 QASS/1LU

00.103.01/P02

STM64 (W): SLOT 1/PORT 2/16

STM64 (P): SLOT 3/PORT 2/16

via optical cable

X-CONN INFO

METRO ADMU

X-CONN INFO

TS/TRIB

SDH NODE

CC17.112

00.103.01/P03

CC14.151

1.17

601 QASS/1MU

SITE: 601 QASSIM

SDH TRANSMISSON FACILITY:


LambdaUnite MSS DDF LINK
Flr/BayLoc/Pnl/Conn
To MESH NETWORK

STM-64 Link Assignment (LINE/SLOT/PORT/AU4 SLOT)

STM-64 ODF (155Mbps)

SDH TRANSMISSON FACILITY:


STM-64 ODF (155Mbps)

STM-64 Link Assignment (LINE/AU4 SLOT)

Flr/BayLoc/Pnl/Conn.(Tx-Rx)

WORKING

PROTECTION

via optical cable

STM64 (W): LS1/CORE1/16

STM64 (P): LS2/CORE2/16

Flr/BayLoc/Pnl

Flr/RowBay/Pnl/Conn
G/106.06/07/07ac

TIE CABLE INFO.:


GROUND FLOOR

FIRST FLOOR

Flr/Bay Loc/Pnl/Conn

Flr/Bay Loc/Pnl/Conn

00.102.03/08/11bd

01.408.04/08/11bd

Issue: 00 Date: 13-Apr-2008


NI- 77559/0
TFR# 01-08040036
File: J:/CWO DESIGN\NEW CWOs\gsm\gsme7\bsc\riyadh(105)\193534270.xls.ms_office
RN: 80270
Circuit Type : GSM-RBS
Part of GSM C I Project

Page 3 of 22

LONG DISTANCE NETWORK


SYSTEM DESIGN CARD

2 Mbit/s Facility ID:

BSC/105-RBS/607 30N01

Circuit Type

GSM-RBS

Continuation..

DACS4/4/1 INFO.:
DDF (155Mbps)

EQUIPMENT LOCATION

PORT ID

Flr/Bay Loc/Pnl/Conn

Flr/Bay Loc/Pnl

Subrack#/Card#/Port

01/401.03/06/07db

01/402.03/P02

10 / 01 / 03

X-CONN INFO
1.5.1

EQUIPMENT LOCATION

PORT ID

Flr/Bay Loc/Pnl

Subrack#/Card#/Port

01/406.03/P03

05 / 11 / 03

X-CONN INFO

DDF (155Mbps)

TPU/TRIB

SDH NODE

8.37

601 QASS/57WH

01/401.03/01/10/37

ODF

SDH RING

Flr/Bay Loc/Pnl/Conn
2.6.1

01/408.05/06/07db

SDH TRANSMISSION FACILITY:


COAX DDF (155Mbps)

TPU/TRIB

Flr/Bay Loc/Pnl/Conn
01/401/08.05/06/07ac

X-CONN INFO

ADM-16

X-CONN INFO

HIGH ORDER X-CONN

Flr/Bay Loc/Pnl

HIGH ORDER X-CONN

01/406.07/P04

Subrack 2

X-CONN INFO

3.3.261

ADM DDF(2Mbps)
Flr/BayLoc/Pnl/Blk/Conn

TIE CABLE INFO.:


FIRST FLOOR

SECOND FLOOR

Flr/BayLoc/Pnl/Blk/Conn

Flr/BayLoc/Pnl/Blk/Conn

01/401.03/08/12/46

02/216.07/10/05/46

hiT7070DC/PDH MICROSHELF TRANSMISSION FACILITY INFO:


SIEMENS DDF (2 Mbps)

SDH NODE

IF2M

Flr/Bay.Loc/Pnl.Blk/Row/Pin
02/215.13/02.01/04/1-6

601 QASS/02S6

Slot/Trib

Flr/BayLoc/Pnl

207.7

02/216.13/P03

Line
ESM -Core Slot/AU4

131

201.02

X-CONN INFO

hiT7070DC -TRANSMISSION FACILITY:


SF10G (211)

to LNQ622 SUBRACK 1

SF10G (211)

hiT7070DC

IFS10G

VC4/INDEX

Slot-Port/AU4

AU4 VC4/AU3 TRIB

Flr/BayLoc/Conn

IFQGBE/ Slot/AU4 PORT

02/131

209.01/02

07/353

02/216.13/P04

103/07

X-CONN INFO.

Flr/BayLoc/Pnl/Conn(Tx,Rx)
3.5.3

02.217.07/02/17-18

hiT7070DC

X-CONN INFO.

Qa01-7

SITE: 602 QASSIM


SDH TRANSMISSION FACILITY:
SDH RING
Qa01-7

ODF

IFS10G

SF10G_211

Flr/Bay Loc/Pnl/Conn

IFQGBE/ Slot/AU4 PORT

VC4 / Trib

01/105.01/04/18-17

104/07

07 / 353

Flr/Bay Loc/Pnl
3.5.3

01/108.05/04

2.161

hiT7060

EI2W / Trib

SDH NODE

LINE CARD

SDH RING

LW-201.01

LE-202.1

SF10G_211 CV4-01

SF10G_211 VC4-02

Qa03-2

SITE : 607 QASSIM


SDH TRANSMISSION FACILITY:
SDH RING

LINE CARD

X-CONN INFO.

Flr/Bay Loc/Pnl
Qa03-2

CCS16-28

CCS16-29

2.161

Siemens DDF (2Mbps)


Flr/Bay Loc/ Pnl.Blk/ Row/Pin

G/206.05/04

LC5 / 16

QASSIM 607/01S7

G/205.05/01.01/08/7-12

M/W TRANSMISSION FACILITY:


GSM DSX

GSM DSX

IDU

M/W

FR/Pnl/PR

DSX Rack/Pnl/Conn

DSXRack#/IDU/Ch.

LINK

tbd

//

//

SITE: ZQSA980-M001
M/W TRANSMISSION FACILITY:
M/W

IDU

GSM DSX

GSM DSX

LINK

DSXRack#/IDU/Ch.

DSX Rack/Pnl/Conn

DSX Rack/Pnl/Conn

//

//

//

RBS-BTS
ZQSA980-M001

Issue: 00 Date: 13-Apr-2008

NI- 77559/0
TFR# 01-08040036
File: J:/CWO DESIGN\NEW CWOs\gsm\gsme7\bsc\riyadh(105)\193534270.xls.ms_office
RN: 80270
Circuit Type : GSM-RBS
Part of GSM C I Project

Page 4 of 22

MADMU 2Mbps Facility Assignment

Facility ID:

RIYADH 10500000/2MU
FLOOR : SECOND

Riyadh 10500000/2MU IS02


C
C
3
3

Metro ADMU
Metro ADMU DDF

02.100B.09P03

DIXI DDF (PBE4)


T.S.

APPL.

RN

PRN

ST TLN

TERM

58

ALJAWAL

80270

36334

30542-001

105-607

PREVIOUS FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

TS

Trib

58

RowBay/Pnl/Blk/Conn)

361

100B.08

07/

15/

58

Date printed: 12/4/2013


Time: 10:47 AM

LONG DISTANCE

Metro ADMU / Metro ADMU Facility Assignment


(RiFon105 + RiMeshNtwk-01 + RiFon107)

Facility ID:
Riyadh 105/2MU - Riyadh 107/1MU VC4S02

RIYADH 10500000/2MU

I
N
D
E
X

FLOOR : SECOND
ADMU
02.100B.09/P03

T.S.

APPL.

RN

PRN

ST TLN

TERM

ALJAWAL

80270

36334

30542-001

105-607

PREVIOUS FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

Line

AU4

CC

LS1/01

19

36

112

RIYADH 10700000/1MU
FLOOR : THIRD
ADMU
03.128.06/P03
Line

AU4

CC

LS1/01

27

24

Revision :
0:25-July-98
1: 14-SEP-98
Fn: \CWODshrd\ld_txn\m1400\ism-ism\westerm\193534270.xls.ms_office

Date printed: 12/4/2013


Time: 10:47 AM

Huawei )OSN9500-OSN3500 FACILITY ASSIGNMENT

RIYADH 10500000/1LU

RIYADH 10500000/2MU

STM64 (W): SLOT 1/PORT 2

STM64 (W): LS1/CORE1

STM64 (P): SLOT 2/PORT 2


FLOOR : SECOND
AU4 Slot

Facility ID

TLN

PRN

(VC4 ckts only)

DDF/ODF

02.100A.09/P02

BayLoc/Pnl/Conn

CardType

Slot

Trib/TS

ODF Position

I
N
D
E
X

STM64 (P): LS2/CORE2


FLOOR : SECOND
02.100B.09/P03
ODF Position

CardType

Slot

DDF/ODF

Trib/TS

BayLoc/Pnl/Conn

Riyadh 105/2MU - Riyadh 114/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC13)

Riyadh 105/2MU - Riyadh 119/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC14)

Riyadh 105/2MU - Riyadh 107/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC15)

Riyadh 105/2MU - Riyadh 106/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC16)

Riyadh 105/2MU - Riyadh 108/1MU VC4S04

To MESH NETWORK

LOW ORDER (CC17)

Riyadh 105/2MU - Riyadh 109/1MU VC4S02

To MESH NETWORK

LOW ORDER (CC18)

Riyadh 105/2MU - Riyadh 121/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC19)

Riyadh 105/2MU - Riyadh 111/1MU VC4S02

To MESH NETWORK

LOW ORDER (CC20)


LOW ORDER (CC21)

Riyadh 101/2MU - Riyadh 105/2MU VC4S05

To MESH NETWORK

10

Riyadh 103/1MU - Riyadh 105/2MU VC4S02

To MESH NETWORK

10

LOW ORDER (CC22)

11

Riyadh 102/1MU - Riyadh 105/2MU VC4S01

To MESH NETWORK

11

LOW ORDER (CC25)

12

Riyadh 105/2MU - Riyadh 108/1MU VC4S01

To MESH NETWORK

12

LOW ORDER (CC24)

13

Riyadh 104/1MU - Riyadh 105/2MU VC4S01

To MESH NETWORK

13

LOW ORDER (CC26)

14

Riyadh 104/1MU - Riyadh 105/2MU VC4S02

To MESH NETWORK

14

LOW ORDER (CC27)

15

Riyadh 101/2MU - Riyadh 105/2MU VC4S06

To MESH NETWORK

15

LOW ORDER (CC28)

16

Riyadh 102/1MU - Riyadh 105/2MU VC4S02

To MESH NETWORK

16

17

Riyadh 105/2MU - Riyadh 108/2MU VC4S05

To MESH NETWORK

17

18

19

TFR 01-08020153
Riyadh 105/2MU - Riyadh 107/1MU VC4S02

77892

34677

To MESH NETWORK

LOW ORDER (CC29)


LOW ORDER (CC31)

18

20

20

21

21

22

22

23

23

24

24

25

25

26

26

27

27

28

28

29

29

30

30

02.100A.01/02/33-34(o) W

TS

02.100A.08/03/29-30(o) P

LOW ORDER (CC36)

19

To MESH NETWORK

TS

31

31
via optical cable

32

32

33

33

34

34

35

35

36

36

37

37

38

38

39

39

40

40

41

41

42

42

43

43

44

44

45

45

46

46

47

47

48

48

49

49

50

50

51

51

52

52

53

53

54

54

55

55

56

56

57

57

58

58

59

59

60

60

61

61

62

62

63

63

64

64

Fn: \CWODshrd\ld_txn\m1400\stm-16\193534270.xls.ms_office

via optical cable

Revision:

Date printed: 12/4/2013


Time: 10:47 AM

LambdaUnite MSS / Metro ADM-U Facility Assignment


Facility ID: Riyadh 10700000/2LU - Riyadh 10700000/1MU STM64
RIYADH 10700000/2LU

RIYADH 10700000/1MU

OP10 (W): SLOT1/PORT 1

STM64 (W): LS1/CORE1

STM64 (P): SLOT2/PORT 1


as per approved MOP
AU4 Slot

FLOOR : THIRD

TLN

Facility ID

PRN

(VC4 ckts only)

DDF/ODF

03.128.06/P02

BayLoc/Pnl/Conn

CardType

Slot

Trib/TS

ODF Position

I
N
D
E
X

STM64 (P): LS2/CORE2


FLOOR : THIRD
03.128.06/P03
ODF Position

CardType

Slot

DDF/ODF
Trib/TS

BayLoc/Pnl/Conn

Riyadh 107/1MU- Riyadh 116/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC1)

Riyadh 104/1MU- Riyadh 107/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC2)

Riyadh 107/1MU- Riyadh 114/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC4)

Riyadh 107/1MU - Riyadh 121/1MU VC4S01

To MESH NETWORK

LOW ORDER (CC5)

Riyadh 105/2MU - Riyadh 107/1MU VC4S01

To MESH NETWORK

80220

29909

To MESH NETWORK (RiMeshNtw-01)

76657

31609

To MESH NETWORK

TFR#01-07080085

LOW ORDER (CC6)


TS

12

03.129.09/07/002ac

TS

129.07/01/01-02 (o) W

TS

129.07/01/33-34 (o) P

TFR 01-07090198

Riyadh 106/1MU- Riyadh 107/1MU VC4S01

To MESH NETWORK (RiMeshNtw-01)

LOW ORDER (CC9)

Riyadh 107/1MU- Riyadh 109/1MU VC4S01

To MESH NETWORK (RiMeshNtw-01)

LOW ORDER (CC10)

10

Riyadh 107/1MU- Riyadh 108/1MU VC4S01

To MESH NETWORK (RiMeshNtw-01)

10

11

ITMC/116-00-726 - ITMC/304-00-441 (TFR#01-08030239)

To MESH NETWORK (RiMeshNtw-01)

11

12

Riyadh 102/1MU - Riyadh 107/1MU VC4S01

To MESH NETWORK (RiMeshNtw-01)

12

13

Riyadh 107/1WD - Riyadh 10700305/1MU VC4-1 (RiC334-1)

14

Riyadh 106-00-422/01S6-Riyadh 107/1WD VC4S06

77775

33473

15

ITMC/107-00-305 - ITMC/304-00-441 (TFR#01-08030244)

79765

33327

16

Riyadh 107/1MU - Jeddah 209/1MU IS01

17

occupied by NI-76694

18
19
20

TFR 01-08020142
TFR 01-08020124

33318

to RiC334-1

TFR 01-08010489

22

TFR#01-07110035

23

To RiC112-1(VC4-1)

24

ITMC/107-ITMC/107-00-305 (PRN 35995)

25

TFR#01-07110103

26

Riyadh 106/2MU- Riyadh 107/1MU VC4S02

27

Riyadh 105/2MU - Riyadh 107/1MU VC4S02

28

Riyadh 101/2MU - Riyadh 107/1MU VC4S01


Riyadh 107/2MU - Riyadh 10700305/1MU VC4-2

OP10D

35.2

10

To MESH NETWORK (RiMeshNtw-01)


to RiC334-1

OP10D

35.2

LOW ORDER (CC12)


TS

13

TS

15
16

03.129.09/07/005ac

14

TS

19

129.09/07/009ac

15

TS

18

03.129.09/07/008ac

LOW ORDER (CC13)

16

To MESH NETWORK (RiMeshNtw-01)

03.129.09/07/06ac

LOW ORDER (CC18)

17
77950
78143

34118
33755

Riyadh 107/1MU- Riyadh 108/2MU VC4S02

21

29

79770

18

To RiMeshNtwk-01

19

To MESH NETWORK (RiMeshNtw-01)

35166

77720

32743

78931

32746

03.129.07/01/07-08 (o)

TS

03.129.07/02/03-04 (o)

TS

03/129.07/01/09-10 (o)

TS

03/129.07/02/05-06 (o)

20

To MESH NETWORK (RiMeshNtw-01)


77664

TS

LOW ORDER (CC19)

to RiC334-1

OP10D

35.2

12

21

TS

to RiC334-1

OP10D

35.2

13

22

TS

To RiC112-1

OP10D

1.1

23

to ring RiC334-1

OP10D

35.2

16

24

TS

03/129.07/01/03-04 (o)

to ring RiC334-1

OP10D

35.2

15

25

TS

03/129.07/02/09-10 (o)

26

To MESH NETWORK (RiMeshNtw-01)


To MESH NETWORK (RiMeshNtw-01)
To MESH NETWORK (RiMeshNtw-01)
to RiC334-1

OP10D

35.2

17

03/129.07/01/11-12 (o)

03/129.07/02/07-08 (o)

LOW ORDER (CC20)

LOW ORDER (CC23)

27

LOW ORDER (CC24)

28

LOW ORDER (CC25)

29

LOW ORDER (CC27)

30

30

31

31
via optical cable

32

32

33

33

34

34

35

35

36

36

37

37

38

38

39

39

40

40

41

41

42

42

43

43

44

44

45

45

46

46

47

47

48

48

49

49

50

50

51

51

52

52

53

53

54

54

55

55

56

56

57

57

58

58

59

59

60

60

61

61

62

62

63

63

64

64

Fn: \CWODshrd\ld_txn\m1400\stm-16\193534270.xls.ms_office

via optical cable

Revision:

MADMU 2Mbps Facility Assignment

Facility ID:

RIYADH 10700000/1MU
FLOOR : THIRD

Riyadh 10700000/1MU IS03


C
C
1
5

Metro ADMU
Metro ADMU DDF

03.128.06.03

DIXI DDF (PBE4)


T.S.

APPL.

RN

PRN

ST TLN

TERM

15

ALJAWAL

80270

36334

30542-001

105-607

PREVIOUS FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

TS

Trib

15

RowBay/Pnl/Blk/Conn)

153

129.08/

02/

04/

15

Date Printed: 12/4/2013


page IS02

OSN3500 2Mb Facility Assignment


Grooming Equipment
Facility ID:
Riyadh 107/05HD IS02

RIYADH 107/05HD
FLOOR: THIRD
Optix DDF

OSN3500
03.109.01/P01

Huawei
T.S.

APPL.

RN

PRN

ST TLN

TERM

23

ALJAWAL

80270

36334

30542-001

105-607

J:\CWOSHRD\JUN_ISM\RIYADH\RIC03193534270.xls.ms_office

FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

(Bay Loc/Panel/Blk/Row(Tx-Rx)/Port)

117.04/

03/06/

04-03/

07

Board_slot

Trib

PQ1_3

23

REVISION:
0:04DEC98
1:07JUN99

Date printed: 12/4/2013


Page: VC4S01

OSN3500-ADMU Facility Assignment


(RiFON107)
RIYADH 10700000/05HD

Facility ID:
Riyadh 107/3MU - Riyadh 107/05HD IS01 (PIPE)

RIYADH 10700000/3MU

FLOOR : THIRD

Huawei TS

APPL.

RN

PRN

ST TLN

TERM

60

ALJAWAL

80270

36334

30542-001

105-607

PREVIOUS FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

OSN3500 DDF

OSN3500

COAX 155 Mbps

O03.109.01/P01

BayLoc/Pnl/Conn(Tx-Rx)

Card_Slot/Port

VC12

03.117.04/P02A/005 (e)

SEP1_15.5

60

I
N
D
E
X

363

FLOOR : THIRD
ADMU DDF

ADMU
03.106.02/P03
CC16

DDF
(BayLoc/Pnl/Blk/Conn)

TS

Trib

03.105.01/07/0013ac

3.11

363

:J:S\\riytf1\stc-cwo\cwodshrd\ld_txn\m1400\PIPE\193534270.xls.ms_office

Date printed: 12/4/2013


Time: 10:47 AM

LONG DISTANCE

Metro ADMU / Metro ADMU Facility Assignment


(RiFon107 + Lucent MESH + QaFON601)

Facility ID:
Riyadh 107/3MU - Qassim 601/1MU VC4S14

RIYADH 10700000/3MU
FLOOR : THIRD
ADMU
03.106.02/P03

T.S.

APPL.

RN

PRN

ST TLN

TERM

ALJAWAL

80270

36334

30542-001

105-607

PREVIOUS FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

Line

AU4

CC21

LS1/01

20

112

I
N
D
E
X
112

QASSIM 60100000/1MU
FLOOR : GROUND
ADMU
00.103.01/P03
Line/ Card Slot

AU4

CC17

LS1/CORE1

16

112

Revision :
0:25-July-98
1: 14-SEP-98
Fn: \CWODshrd\ld_txn\m1400\ism-ism\westerm\193534270.xls.ms_office

Date printed: 12/4/2013


Time: 10:47 AM

Huawei )OSN9500-OSN3500 FACILITY ASSIGNMENT

RIYADH 10700000/1LU

RIYADH 10700000/3MU

STM64 (W): SLOT1/PORT 1


STM64 (P): SLOT3/PORT 1
FLOOR : THIRD
AU4 Slot

TLN

Facility ID

PRN

(VC4 ckts only)


1
2

Riyadh 107/3MU - Dammam 304/3MU VC4S01


Riyadh 107/3MU - Jeddah 214/1MU VC4S01

Riyadh 101/1MU - Riyadh 107/3/MU VC4S01

TFR#01-07080085

TFR#01-07080086

DDF/ODF

03.106.02/P02

BayLoc/Pnl/Conn

CardType

Slot

Trib/TS

ODF Position

STM64 (P): LS2/CORE2


FLOOR : THIRD
03.106.02/P03
ODF Position

CardType

Slot

DDF/ODF
Trib/TS

BayLoc/Pnl/Conn

To MESH NETWORK (ER-16)

To MESH NETWORK (CR-25)

To MESH NETWORK

80220

29909

To MESH NETWORK (ER#16))

TS

13

03.105.01/07/003ac

77081

29934

To MESH NETWORK (CR-25)

TS

14

03.105.01/07/004ac

To MESH NETWORK (CR-25)

To MESH NETWORK (ER-17)

Riyadh 107/3MU - Jeddah 214/03HG VC4S01


Riyadh 101/1MU - Riyadh 107/3/MU VC4S02

Riyadh 107/3MU - Jeddah 214/03HG VC4S21

9
10

Riyadh 107/3MU - Dammam 304/3MU VC4S02


Riyadh 107/3MU- Dammam 302/3MU VC4S38

11

107-00-302 - 303-00-413 (PRN 31834)

12

107-00-302 - 213-00-202 (PRN 31835)

13

Riyadh 107/3MU - Al Ahsa 324/01MU VC4S04

14

Riyadh 107/3MU - Qassim 601/1MU VC4S13

15

ITMC/116-00-726 - ITMC/304-00-441 (TFR#01-08030239)

79770

33318

16

ITMC/107-00-305 - ITMC/304-00-441 (TFR#01-08030244)

79765

33327

17

Riyadh 107/3MU- Jeddah 206/1MU VC4S01

18

Riyadh 107/3MU - Jeddah 214/1MU VC4S02

19
20

LOW ORDER CC1


LOW ORDER CC2
LOW ORDER CC4

LOW ORDER CC (CC6)


TS

16

03.105.01/07/006ac

To MESH NETWORK (CR-25)

LOW ORDER CC8

To MESH NETWORK

LOW ORDER CC9

To MESH NETWORK

10

78416

31834

To MESH NETWORK

11

TS

TS

LOW ORDER CC10


18

03.105.01/07/008ac

19

03.105.01/07/009ac

78420

31835

To MESH NETWORK (CR-25)

12

To MESH NETWORK

13

LOW ORDER CC11

To MESH NETWORK (CR-25)

14

LOW ORDER CC13

To MESH NETWORK (ER-16)

15

TS

To MESH NETWORK (ER-16)

16

TS

To MESH NETWORK (CR-25)

17

LOW ORDER CC13

To MESH NETWORK (CR-25)

18

LOW ORDER CC17

Riyadh 107/3MU- Jeddah 206/04HD VC4S02

To MESH NETWORK (CR-25)

19

LOW ORDER CC20

Riyadh 107/3MU - Qassim 601/1MU VC4S14

To MESH NETWORK (CR-25)

20

LOW ORDER CC21

21

21

22

22

23

23

24

24

25

25

26

26

27

27

28

28

29

29

20

03.105.01/07/0010ac

21

03.105.01/07/011ac

30
31

31
32

STM64 (W): LS1/CORE1

30

Fn: \CWODshrd\ld_txn\m1400\stm-16\193534270.xls.ms_office

I
N
D
E
X

via optical cable

32

33

33

34

34

35

35

36

36

37

37

38

38

39

39

40

40

41

41

42

42

43

43

44

44

45

45

46

46

47

47

48

48

49

49

50

50

51

51

52

52

53

53

54

54

55

55

56

56

57

57

58

58

59

59

60

60

61

61

62

62

63

63

64

64

via optical cable

Revision:

Date printed: 12/4/2013


Time: 10:47 AM

Huawei )OSN9500-OSN3500 FACILITY ASSIGNMENT

60100000/1LU

60100000/1MU

STM64 (W): SLOT1/PORT 2

STM64 (W): LS1/CORE1

STM64 (P): SLOT3/PORT 2


FLOOR : GROUND
AU4 Slot

TLN

Facility ID

PRN

(VC4 ckts only)

DDF/ODF

00.103.01/P02

BayLoc/Pnl/Conn

76242

28261

CardType

Slot

ODF Position

STM64 (P): LS2/CORE2


FLOOR : GROUND
00.103.01/P03
ODF Position

DDF/ODF

CardType

Slot

Trib/TS

BayLoc/Pnl/Conn

LKA39

11

00.106.06/07/01ac

To MESH NETWORK (NR#7)

To MESH NETWORK

LOW ORDER (CC1)

To MESH NETWORK (NR#7)

LOW ORDER (CC3)

LOW ORDER (CC4)

409-602 (PRN 28261)

Mujammah 214/03HG- Qassim 601/1MU VC4S09

Jeddah 20500205/06HD - Hail 60100000/1MU VC4S01

Riyadh 107/3MU - Qassim 601/1MU VC4S13

To MESH NETWORK (CR-25)


to CRLS3 SS3

STM64

23

01

LOW ORDER (CC?)

601-SS3-401 VC4S02

to CRLS3 SS3

STM64

23

01

LOW ORDER (CC5)

601-SS3-401 VC4S03

to CRLS3 SS3

STM64

23

01

LOW ORDER (CC7)

To MESH NETWORK (NR#7)

LOW ORDER (CC8)

TFR#06-07070055

6
7
8

Northern Border 413/1MU - Qassim 601/1MU VC4S01

29173

Trib/TS

I
N
D
E
X

Jeddah 206/1MU - Qassim 601/1MU VC4S01

To MESH NETWORK (NR#7)

LOW ORDER (CC9)

10

Medinah 401/1MU - Qassim 601/1MU VC4S18

To MESH NETWORK

10

LOW ORDER (CC10)

11

Riyadh 108/3MU - Qassim 601/1MU VC4S01

To MESH NETWORK (CR-25)

11

LOW ORDER (CC11)

12

Jeddah 206/04HD - Qassim 601/1MU VC4S02

To MESH NETWORK (CR-25)

12

LOW ORDER (CC12)

To MESH NETWORK (CR-25)

13

LOW ORDER (CC13)

14

LOW ORDER (CC15)

13

Jouf 408/1MU-Qassim 601/1MU VC4S01

14
15

Riyadh 101/1MU - Qassim 601/1MU VC4S01


111-601-SS4_VC4-15 STM64

16

Riyadh 107/3MU - Qassim 601/1MU VC4S14

To MESH NETWORK (CR-25)


to 111-SS4-611
STM64
15/02

15

15

LOW ORDER (CC16)

16

To MESH NETWORK (CR-25)

17

17

18

18

19

19

20

20

21

21

22

22

23

23

24

24

25

25

26

26

27

27

28

28

29

29

30

30

LOW ORDER (CC17)

31

31
03.102.08/03A/??

32

32

33

33

34

34

35

35

36

36

37

37

38

38

39

39

40

40

41

41

42

42

43

43

44

44

45

45

46

46

47

47

48

48

49

49

50

50

51

51

52

52

53

53

54

54

55

55

56

56

57

57

58

58

59

59

60

60

61

61

62

62

63

63

64

64

Fn: \CWODshrd\ld_txn\m1400\stm-16\193534270.xls.ms_office

03.102.08/03A/??

Revision:

Date printed: 12/4/2013


Time: 10:47 AM

LONG DISTANCE

Metro ADMU / DACS 4/4/1 Facility Assignment


(QaFon601)
Note: pls. see centjump file for the STM1e tie cable assignment.
QASSIM 60100000/1MU
QASSIM 601/1WD
FLOOR : GROUND

Facility ID:
Qassim 601/1MU - Qassim 601/1WD IS02

ADMU DDF

ADMU
103.01/P03

T.S.

APPL.

RN

PRN

ST TLN

TERM

13

ALJAWAL

80270

36334

30542-001

105-607

PREVIOUS FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

DDF

CC14

(BayLoc/Pnl/Blk/Conn)

TS/Trib

106.06/07/07ac

1.17

FLOOR : FIRST
I
N
D
E
X

151

DACS 4/4/1

DACS 4/4/1 DDF

402.03/P02
PSA Subrack / STM-1 unit

COAX 155 Mbps

PORT ID

(BayLoc/Pnl/Conn)

(Sub.No./Card No./Port)

401.03/06/07db

10 / 01 / 03

Revision :
0:25-July-98
1: 14-SEP-98
Fn: \CWODshrd\ld_txn\m1400\ism-ism\westerm\193534270.xls.ms_office

ADM16/1-DACS4/4/1 Facility Assignment


(QaFon/601)
QASSIM 601

Facility ID:
Qassim 601/1WD-Qassim 601/57WH 1S28

QASSIM 601/57WH (CR #17)

FLOOR : FIRST
DACS 4/4/1

DACS 4/4/1 DDF

406.03/P03
PSA Subrack / STM-1 unit

T.S.

APPL.

RN

PRN

ST TLN

TERM

37

ALJAWAL

80270

36334

30542-001

105-607

PREVIOUS FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

FLOOR: FIRST

I
N
D
E
X

ADM-16/1
406.07/P04
TS

COAX 155 Mbps

PORT ID

COAX 155 Mbps

(BayLoc/Pnl/Conn)

(Sub.No./Card No./Port)

(BayLoc/Pnl/Conn)

408.05/06/07db

05 / 11 / 03

261

408.05/06/07ac

TPU Trib

TS
Horizontal DIXI

TPU Trib

(BayLoc/ Pnl/ Blk/ Conn)

3.3

261

401.03/

01/

10/

37

37 J

Date printed:12/4/2013
Time:10:47 AM

JUNCTION NETWORK

hiT7070DC/PDH Microshelf Facility Assignment


Facility ID:
Qassim 60100000/02S6 IS02

60100000/02S6
FLOOR: SECOND
hiT7070DC

SF10G
SUBRACK-1
02.216.13/P04
LNQ622

Qa01-7
211
T.S.

APPL.

RN

PRN

ST TLN

TERM

ALJAWAL

80270

36334

30542-001

105-607

J:\\stc-cwo\cwoshrd\junction_ism\riyadh\riyadh-10g\193534270.xls.ms_office

PREVIOUS FACILITY ID
BSC/105-RBS/607 30N01 (ZQSA980-M001)

VC4

INDEX

Slot.Port

02

131

209.01

Worksheet: IS02 (3)

AU4
02

SUBRACK-2 (PDH Microshelf)


02.216.13/P03
Line

IF2M

ESM-Core
Slot

AU4

201

02

DDF
(BayLoc/ Pnl.Blk/ Row/Pin)

215.13/02.01/

04/1-6

Slot

Trib

207

Revision
12/4/2013

Date printed:12/4/2013
Time:10:47 AM

JUNCTION NETWORK

hiT7070DC/hiT7070DC Facility Assignment


(QaFON601 + Qa01-7 + QaFON602)
Facility ID:
Qassim 601/01S6- Qassim 602/01S6 VC4S01

601/02S6
FLOOR: SECOND
hiT7070DC
02.216.13/P04
IFS10G
ODF

T.S.

APPL.

RN

PRN

ST TLN

57

ALJAWAL

80270

36334

30542-001

TERM

PREVIOUS FACILITY ID

105-607 BSC/105-RBS/607 30N01 (ZQSA980-M001)

J:\\stc-cwo\cwoshrd\junction_ism\riyadh\riyadh-10g\193534270.xls.ms_office

(BayLoc/Pnl/Conn)

00.101.01/06/17-18

Worksheet: VC4S01 (2)

SF10G_211

Slot

AU4

VC4

Trib

103

07

07

353

I
N
D
E
X

602/01S6
FLOOR: FIRST
hiT7070DC
01.108.05/P04
IFS10G
ODF
(BayLoc/Pnl/Conn)

353

01.105.01/04/18-17

SF10G_211

Slot

AU4

VC4

Trib

104

07

07

353

Revision
12/4/2013

Date Printed: 12/4/2013


Page 601W-602E

JUNCTION NETWORK

hiT7070DC / hiT7070DC Facility Assignment


(601, 602)

Same equipment in Ring Qa03-2

Facility ID:

60100000/02S6
Line WEST (103)

Qa01-7 601/01S6-602/01S6 64S01

AU4
1
2
3
4
5

APPL.

FLOOR : SECOND
02.216.13/P04

ODF/DDF COAX

MOP#4-SI-8-JN-0030

RN

AL JAWAL 72219
AL JAWAL 72222
AL JAWAL 72223
AL JAWAL 72220
AL JAWAL 72226

PRN
21936
21938
21939
21937
21940

ST TLN TERM
n/a

PREVIOUS FACILITY ID

601-602

n/a

PRN 21936 (TFR#06-07070021)

332-602

n/a

GFP Group

VC4

STM

GE

GE

02.215.13/10/09-10 (o) W

IFO155M_111

02.215.13/08//01-02 (o) P

IFO155M_112

PRN 21940

202

01

02.216.11/09/002(e)

202

02

03

602-615

Qassim 602/01S6- Qassim 615/01S6 VC4S01

THROUGH CONNECT

04
05

02.216.11/09/003(e)
6

ODF
IFS10G_104

02
02.216.11/09/001(e)

TFR#06-07070023

403-602

60200000/01S6
Line EAST (104)

01

PRN 21939

602-615

n/a

Port

Card_Slot

PRN 21938

332-602

n/a

Card_Slot
BayLoc/Pnl/(Row/Pin)

ODF
IFS10G_103

I
N
D
E
X

202

03

THROUGH CONNECT

06

FLOOR : FIRST
01.108.05/P04

ODF/DDF COAX

GFP Group

VC4

Card_Slot

Port

GE

GE

Card_Slot

STM

n/a

n/a

IFO155M_111

03

n/a

n/a

IFO155M_112

03

01.109.05/09/05-06 (o) P

n/a

n/a

IFO155M_111

05

01.109.05/10/17-18 (o) W

n/a

n/a

IFO155M_112

05

01.109.05/09/09-10 (o) P

n/a

n/a

IFO155M_111

06

01.109.05/10/19-20 (o) W

n/a

n/a

IFO155M_112

06

01.109.05/09/11-12 (o) P

n/a

n/a

IFO155M_111

04

01.109.05/10/15-16 (o) W

n/a

n/a

IFO155M_112

04

01.109.05/09/07-08 (o) P

n/a

n/a

IFO155M_111

06

01.109.05/10/21-22 (o) W

n/a

n/a

IFO155M_112

06

01.109.05/09/13-14 (o) P

BayLoc/Pnl/(Row/Pin)
01.109.05/10/13-14 (o) W

LOW ORDER

Qassim 601/01S6- Qassim 602/01S6 VC4S01

LOW ORDER

07

LOW ORDER

Qassim 601/01S6- Qassim 602/01S6 VC4S02

LOW ORDER

08

LOW ORDER

Qassim 601/01S6- Qassim 602/01S6 VC4S03

LOW ORDER

09

LOW ORDER

10

G-SHDSL

73221

19534

02.215.11/10/01-02(o)

IFQGBEB_101

01

01

01

10

11

DATA

74249

21512

n/a

601-602 601-602 (PRN 21512)

02.215.11/10/03-04(o)

IFQGBEB_101

01

01

09

11

02

10

IFQGBEB_101

02

12

DATA

74249

21512

n/a

601-602 601-602 (PRN 21512)

02.215.11/10/03-04(o)

IFQGBEB_101

01

01

10

12

02

11

IFQGBEB_101

02

01.109.05/10/05-06(o)

02.215.13/10/21-22(o) (w)

IFO155M_111

07

---

---

---

---

IFO155M_112

08

01.109.05/09/15-16(o) (w)

02.215.13/08/13-14(o) (p)

IFO155M_112

07

---

---

---

---

IFO155M_111

08

01.109.05/10/23-24(o) (P)

---

---

IFO155M_110

03

01.109.05/07/29-30(o) (P)

13

DXX

75079

28258

601-604

n/a

TFR#06-07040004

601-602

14

TFR# 06-07070022

PRN 28258

Qassim 601/01S6 - Qassim 602/01S6 VC4S04

13

LOW ORDER

14

00.101.01/06/17-18

15
16

THROUGH CONNECT

15

01.109.05/10/05-06(o)

01.105.01/04/18-17

16

17

17

18

18

19

19

20

20

21

21

22

22

23

23

24

24

25

25

26

26

27

27

28

28

29

29

30

30

31

31

32

32

33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49

MS Spring Protection slot

FOR SDH RING PROTECTION SLOTS.

50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
TOTAL:

\\STC-CWO\cwoshrd\junction_ism\riyadh\riyadh_10g\193534270.xls.ms_office

882

Revision:
12/4/2013

602; 607
Facilityn ID:

60200000/01S6
I
N
D
E
X

Qa03-2 (STM-16 Ring) VC4-02


MOP#4-SI-8-JN-0097
T.S.
APPL.
RN

16

ALJAWAL

20 of 20

See 2Mb inventory in hiT shared file.

HIT7070, HIT7060 Facility Assignment

80270

PRN

36334

ST TLN

TERM

FACILITY ID

30542-001 105-607 BSC/105-RBS/607 30N01 (ZQSA980-M001)

2.161

LW-201.01

60700000/01S7

LINE CARD

SF10G_211 VC4-01
FLOOR: FIRST
SIEMENS DDF

LE-202.1 CCS16-28

LINE CARD

CCS16-29

SF10G_211 VC4-02
hiT7070DC
01.108.05/P04

(Flr.Bay.loc/ Pnl.Blk/ Row/Pin)

EI2W
Slot_AU4

Trib

to Qa01-7

104_7

353

FLOOR: GROUND
SIEMENS DDF
(Flr.Bay.loc/ Pnl.Blk/ Row/Pin)

00.205.05/01.01/

08/7-12

hiT7060
00.206.05//P04
EI2W Trib

LC5

16

Anda mungkin juga menyukai