Anda di halaman 1dari 10

Comparison of Netop Macro Antenna with Existing Andrew Macro Antenna

Confidential
1

Objective

To compare the coverage and quality between ANDREW DBXLH-6565C-VTM and S-WAVE 0809 U-65-17 18DVB. To compare the KPI between ANDREW DBXLH-6565C-VTM and S-WAVE 0809 U-65-17 18DVB.

Confidential
2

Methodology
Coverage and quality of DHK_X0140_1,DHK_X0140_4 has been checked for both type of antennas by drive test. Drive test has been done in dedicated mode [locked] for both 900 & 1800 band for both type of antennas and downlink power was disabled during test . During the drive test, coverage in main lobe as well as side lobe is closely monitored.

Confidential
3

Comparison of Antenna Specification


ANDREW DBXLH6565C-VTM
Antenna Features Gain dBi Horizontal BW Vertical BW Front-To-Back Ratio Electrical Tilt Isolation 900 17 65 7.5 26 0-8 > 30 1800 17.8 65 5 30 0-6 > 30

S-Wave 0809 U-6517 18DVB.


900 17 65 9.5 25 0-8 30 1800 18 62 6 25 0-8 30

Max. input Power


Confidential

250 w

250 w

400 w

300w

Comparison of coverage for 900 band between antennas

Andrew DBXLH6565C-VTM S-wave 0809_U-6517_18DV8

Confidential
5

Comparison of quality for 900 band between antennas

Andrew DBXLH6565C-VTM

S-wave 0809_U-6517_18DV8

Confidential
6

Comparison of coverage for 1800 band between antennas

Andrew DBXLH6565C-VTM

S-wave 0809_U-6517_18DV8

Confidential
7

Comparison of quality for 1800 band between antennas

Andrew DBXLH6565C-VTM

S-wave 0809_U-6517_18DV8

Confidential
8

Conclusion:

Confidential
9

Thank you

Confidential
10

Anda mungkin juga menyukai