DATOS
0.15 m
0.59 m
1. PREDIMENSIONADO
Espesor de la escalera
t = Ln/20
=
t = Ln/25
=
USAR t
=
1.31 m
Pos. 4
1/2 @ 40.5
f'c = 210.00 Kg/cm
Neg. 4
1/2 @ 40.5
fy = 4200.00 Kg/cm
Temp
3/8 @ 39.5
S/C = 400.00 Kg/m
Acabados = 100.00 Kg/m
Bastones: As Negativo y Positivo
b=
1.20 m
Ld = 0.40 m
CP =
0.18 m
P=
0.30 m
30.96
q=
t=
0.20 m
Recub =
2.00 cm
g C = 2400.00 Kg/m3
hm =
0.31 m
CP
t
CP
hm = h
=
2
cos q
2
0.60 m
0.10 m
0.08 m
0.20 m
2. METRADO DE CARGAS
Wu2
Wu1
0.665 m
1.610 m
X
RB
Carga Viva
S/C = 480.00 Kg/m
480.00 Kg/m
WL1 = 816.00 Kg/m
DISTRIBUCION DE ACERO
Carga Viva
S/C = 480.00 Kg/m
480.00 Kg/m
WL1 = 816.00 Kg/m
3. CALCULO DE MOMENTO
2554.84 Kg
RB =
El momento maximo se dar en la seccion que posea el cortante igual a 0
X=
1.14 m
Vx = 0
(+) Mu max =
(+) M diseo =
1454.77 Kg-m
1163.82 Kg-m
1.16 T-m
4. DISEO EN ACERO
Para Momento Positivo: 1.16 T-m
Asumiendo varilla de acero:
b=
120.00 cm
d=
17.37 cm
a=
0.35 cm
As (+) =
1.79 cm
Colocar As min
As (+) =
3.75 cm
S=
40.50 cm
# Varillas =
4
As min =
3.75 cm
Para Momento Negativo:
Asumiendo varilla de acero:
As (-) =
1.25 cm
Colocar As min
As (-) =
3.75 cm
S=
40.50 cm
S max =
60.00 cm
S max =
45.00 cm
S=
40.50 cm
# Varillas =
4
=
As =
1/2
1.27 cm
USAR = 4 1/2 @ 40.5
=
As =
1/2
1.27 cm
USAR = 4 1/2 @ 40.5
Para As de Temperatura:
As temp =
3.60 cm
As temp =
Dos capas
1.80 cm
Asumiendo varilla de acero:
S=
39.50 cm
S max =
100.00 cm
S max =
45.00 cm
S=
39.50 cm
=
As =
3/8
0.71 cm
USAR =
3/8 @ 39.5
N DE ACERO
gativo y Positivo
0.15 m
1.20 m
1. PREDIMENSIONADO
Espesor de la escalera
t = Ln/20
=
t = Ln/25
=
USAR t
=
2.40 m
Pos. 5.5
1/2 @ 27
f'c = 210.00 Kg/cm
Neg. 4
1/2 @ 40.5
fy = 4200.00 Kg/cm
Temp
3/8 @ 39.5
S/C = 400.00 Kg/m
Acabados = 100.00 Kg/m
Bastones: As Negativo y Positivo
b=
1.20 m
Ld = 0.80 m
CP =
0.18 m
P=
0.30 m
30.96
q=
t=
0.20 m
Recub =
2.00 cm
g C = 2400.00 Kg/m3
hm =
0.31 m
CP
t
CP
hm = h
=
2
cos q
2
0.15 m
0.18 m
0.14 m
0.20 m
2. METRADO DE CARGAS
Wu2
Wu1
1.275 m
2.475 m
X
RB
Carga Viva
S/C = 480.00 Kg/m
480.00 Kg/m
WL1 = 816.00 Kg/m
DISTRIBUCION DE ACERO
Carga Viva
S/C = 480.00 Kg/m
480.00 Kg/m
WL1 = 816.00 Kg/m
3. CALCULO DE MOMENTO
4910.48 Kg
RB =
El momento maximo se dar en la seccion que posea el cortante igual a 0
X=
1.80 m
Vx = 0
(+) Mu max =
(+) M diseo =
4420.77 Kg-m
3536.61 Kg-m
3.54 T-m
4. DISEO EN ACERO
Para Momento Positivo: 3.54 T-m
Asumiendo varilla de acero:
b=
120.00 cm
d=
17.37 cm
a=
1.09 cm
As (+) =
5.56 cm
Ok!
As (+) =
5.56 cm
S=
27.00 cm
# Varillas =
6
As min =
3.75 cm
Para Momento Negativo:
Asumiendo varilla de acero:
As (-) =
1.85 cm
Colocar As min
As (-) =
3.75 cm
S=
40.50 cm
S max =
60.00 cm
S max =
45.00 cm
S=
40.50 cm
# Varillas =
4
=
As =
1/2
1.27 cm
USAR =5.5 1/2 @ 27
=
As =
1/2
1.27 cm
USAR = 4 1/2 @ 40.5
Para As de Temperatura:
As temp =
3.60 cm
As temp =
Dos capas
1.80 cm
Asumiendo varilla de acero:
S=
39.50 cm
S max =
100.00 cm
S max =
45.00 cm
S=
39.50 cm
=
As =
3/8
0.71 cm
USAR =
3/8 @ 39.5
N DE ACERO
gativo y Positivo