Anda di halaman 1dari 6

COEFFICIENT DE PERTE DE CHARGE APPLICABLE SUR PORTE-RAMPE

PRESSION D'ENTREE ( BAR )


Coeff. nb. de Rampes 0.4 0.5 0.55 0.6 0.7 0.8 0.9 1 1.1
1.000 1 0.040 0.050 0.055 0.060 0.070 0.080 0.090 0.100 0.110
0.440 5 0.091 0.114 0.125 0.136 0.159 0.182 0.205 0.227 0.250
0.380 10 0.105 0.132 0.145 0.158 0.184 0.211 0.237 0.263 0.289
0.365 15 0.110 0.137 0.151 0.164 0.192 0.219 0.247 0.274 0.301
0.359 20 0.111 0.139 0.153 0.167 0.195 0.223 0.251 0.279 0.306
0.355 25 0.113 0.141 0.155 0.169 0.197 0.225 0.254 0.282 0.310
0.350 30 0.114 0.143 0.157 0.171 0.200 0.229 0.257 0.286 0.314
0.345 40 0.116 0.145 0.159 0.174 0.203 0.232 0.261 0.290 0.319
0.343 50 0.117 0.146 0.160 0.175 0.204 0.233 0.262 0.292 0.321
0.338 100 0.118 0.148 0.163 0.178 0.207 0.237 0.266 0.296 0.325
Calcul du Débit en fonction du Diamètre Intérieur et de la vitesse
Diamètre Intérieur mm 67
Vitesse en mètre/sec 2.5
??? Débit m3/hr ??? = 31.73

Calcul de la Vitesse en fonction du Débit et du Diamètre Intérieur


Diamètre Intérieur mm 23
Débit en m3/hr 3
??? Vitesse mètre/sec ??? = 2.01

Calcul du Diamètre Intérieur en fonction du Débit et de la Vitesse


Débit en m3/hr 3
Vitesse en mètre/sec 2
??? Diamètre Intérieur mm ??? = 23

Pertes de Charge dans les Principales et Porte-rampes


Débit en m3/hr 35
Diamètre Intérieur mm 100
Longueur en mètres 300
Pertes de Charge PVC ou PE (bar) ??? = 0.406

Calcul longueur du tubing pour obtenir la PdC souhaitée


Perte de Charge souhaitée (mètre) 8
Débit en lites par heure 340
Diamètre Intérieur mm 6 Maximum 6 mm ID recommandé
Longueur du tubing (mètres) ??? = 2.88

Source of the friction loss equations : CEMAGREF(Le Tholonet - France)


Pertes de Charge dans tubes P.E. : Hbar  ( Lm * 0. 0478) * mm  4. 75 * Ql / hr  1. 75
Pertes de Charge dans tubing :
Hbar  0. 303 * Lm  0. 662 * mm  4. 432 * Ql / hr  1.804
aximum 6 mm ID recommandé

 4. 75 * Ql / hr  1. 75
mm  4. 432 * Ql / hr  1. 804
Calculate the Flow according to the Diameter and the velocity
Internal diameter mm 63
Velocity meter/sec 2.5
??? Flow m3/hr ??? = 28.06

Calculate the Velocity according to the Flow and the int. Diameter
Internal diameter mm 23
Flow m3/hr 3
??? Velocity meter/sec ??? = 2.01

Calculate the Internal Diameter according to the Flow and the Velocity
Flow m3/hr 3
Velocity meter/sec 2
??? Internal diameter mm ??? = 23

Friction losses in the main pipes and submains


Flow m3/hr 68
Internal diameter mm 125
Length meter 100
Friction losses PVC or PE (bar) ??? = 0.150

Calculate the length of a restrictor to achieve target friction losses


Friction losses targeted (meter) 8
Flow in liter per hour 340
Internal diameter mm 6 Maximum 6 mm ID recommended
Length of the restrictor (meters) ??? = 2.88

Source of the friction loss equations : CEMAGREF(Le Tholonet - France)


Friction losses in P.E. pipes : Hbar  ( L m * 0. 0478) * mm  4. 75 * Ql / hr  1. 75
Friction losses in restrictors :
Hbar  0. 303 * Lm  0. 662 * mm  4. 432 * Ql / hr  1.804
Ql / hr 1.804
COMPOUND MANIFOLD FRICTION LOSS COEFFICIENT
WORKING INLET PRESSURE ( BAR )
Coeff. nb. of laterals 0.4 0.5 0.55 0.6 0.7 0.8 0.9 1 1.1
1.000 1 0.040 0.050 0.055 0.060 0.070 0.080 0.090 0.100 0.110
0.440 5 0.091 0.114 0.125 0.136 0.159 0.182 0.205 0.227 0.250
0.380 10 0.105 0.132 0.145 0.158 0.184 0.211 0.237 0.263 0.289
0.365 15 0.110 0.137 0.151 0.164 0.192 0.219 0.247 0.274 0.301
0.359 20 0.111 0.139 0.153 0.167 0.195 0.223 0.251 0.279 0.306
0.355 25 0.113 0.141 0.155 0.169 0.197 0.225 0.254 0.282 0.310
0.350 30 0.114 0.143 0.157 0.171 0.200 0.229 0.257 0.286 0.314
0.345 40 0.116 0.145 0.159 0.174 0.203 0.232 0.261 0.290 0.319
0.343 50 0.117 0.146 0.160 0.175 0.204 0.233 0.262 0.292 0.321
0.338 100 0.118 0.148 0.163 0.178 0.207 0.237 0.266 0.296 0.325

Anda mungkin juga menyukai