Anda di halaman 1dari 2

COMPONENT CODE:

D8
PARTS & SERVICE NEWS
NO.:
DATE:
AH14529
May 15, 2014
Page 1 of 2
AH14529
SUBJECT: Ground Issue at Node Box 40
PURPOSE: Avoiding of Monitoring Failures by Wrong Sensor Outputs
APPLICATION: PC4000/6; PC5500/6; PC8000/6 (all X2 versions)
FAILURE CODE: D800MA (A3, FCH14547; 14548; 14549)
DESCRIPTION:
Before carrying out any repairs, read all the safety instructions
in the Operation and Maintenance Manual of your shovel, and
those contained in Parts & Service News AH10509 ( Release of
New General safety Precautions).
The local safety rules must also be observed.
Due to a grounding issue, inaccurate pressure sensor measurements may result
depending on the amount of electrical consumption.
E.g.: When the light in machine house is switched on, failure code outputs can occur
although all parts of the machine are working properly.
The following failure codes can be shown:
Solution: We recommend the installation of a bridge between the clamps 40GND and
40AGND as shown on the next page.
Use a cable 2.5 mm and two suitable cable sleeves.
(C)
Page 2 of 2
AH14529


















Location 40

Anda mungkin juga menyukai