EXPERIMENT 1: BATCH REACTOR

Prepare 500mL of 0.1M Na(Ac) and 500mL of 0.1M


NaOH
Determine the conductivity for 0% conversion with the
conductivity meter by mixing 100ml NaOH into 1L of
deionised water in the 1L beaker
Determine the conductivity for 25% conversion with the
conductivity meter by mixing 75ml NaOH and 25ml
Na(Ac) into 1L of deionised water in the 1L beaker
Determine the conductivity for 50% conversion with the
conductivity meter by mixing 50ml NaOH and 50ml
Na(Ac) into 1L of deionised water in the 1L beaker
Determine the conductivity for 75% conversion with the
conductivity meter by mixing 25ml NaOH and 75ml Na(Ac)
into 1L of deionised water in the 1L beaker
Determine the conductivity for 100% conversion with
the conductivity meter by mixing 100ml Na(Ac) into
1L of deionised water in the 1L beaker
Plot the Calibration Curve of Conductivity vs
Conversion after determine all the value.
EXPERIMENT 1:
6.1. Calibration curve - Conductivity Vs Conversion
Set-up the Apparatus and Equipment as shown in Figure 3.1
Heat up 250 ml of 0.1 M Et(Ac) (using 1 L beaker) and 250 ml of 0.1 M
NaOH (using a 1 L beaker) separately in a water bath to 35 .
Pour the NaOH solution was into the 1 L beaker containing ethyl
acetate solution once the solution reach the desired temperature.
Switch the stirrer to 100rpm and record the start-time as t0.
Record the conductivity of the reaction medium every 1 minute until a
constant conductivity was reached.
Repeat the Next step by changing the temperature into 45, then
55and 65
EXPERIMENT 1:
6.2. Determine the rate of reactions