Anda di halaman 1dari 70

DRAWING LIST,LEGEND &ABBREVIATIONS

COMBINATION 60A, 480V, 3 PHASE OUTLET AND 120V


OUTLET WITH MAIN FUSED SWITCH SWITCH & TRANSFORMER(480V-120V)
20A, 125V, 3W, DUPLEX GROUNDING RECEPTACLE, NEMA 5-20R
J
F
ABOVE CEILING JUNCTION BOX(SIZE PER NEC OR AS INDICATED)
F - FLOOR MOUNTED
J
15A, 125V, 3W, SINGLE GROUNDING RECEPTACLE, NEMA 5-15R
20A, 125V, 3W, DUPLEX GROUNDING RECEPTACLE,
GFI - GROUND FAULT INTERRUPTING(5mA) GFI
NON-FUSED SAFETY SWITCH, POLES & SIZE AS NOTED
60A, 480V, 3W, SINGLE GROUNDING RECEPTACLE, NEMA 8-60R
INCANDESCENT, QUARTZ OR HIGH INTENSITY
DISCHARGE LUMINAIRE SEE LUMINAIRE SCHEDULE
WALL MOUNTED UNIT USED WITH ANY SYMBOL
FLUORESCENT SEE LUMINAIRE SCHEDULE
SEE LUMINAIRE SCHEDULE EXIT SIGN, DOUBLE FACE
SEE LUMINAIRE SCHEDULE
EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED, DOUBLE FACE
LUMINAIRES
M
3480V OR 208V MOTOR
MOTOR CONTROLLER, NUMBER DENOTES NEMA STARTER SIZE
MOTORS
BRANCH CIRCUIT DESIGNATION,SEE CABLE SCHEDULE
EXIT SIGN, SINGLE FACE
SEE LUMINAIRE SCHEDULE
EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED, SINGLE FACE SEE LUMINAIRE SCHEDULE
INCANDESCENT, QUARTZ OR HIGH INTENSITY
DISCHARGE LUMINAIRE(EMERGENCY) SEE LUMINAIRE SCHEDULE
INCANDESCENT, QUARTZ OR HIGH INTENSITY LUMINAIRE SEE LUMINAIRE SCHEDULE
FLUORESCENT(EMERGENCY) SEE LUMINAIRE SCHEDULE
SURFACE MOUNTED FLUORESCENT UNDER STEEL STRUT. SEE LUMINAIRE SCHEDULE
LIGHTING & RECEPTACLE PANEL
POWER DISTRIBUTION PANEL
WALL SWITCH 120-277 VOLT, 20 AMP, SINGLE POLE
DOCUMENTS. IF NOT, CONTACT THE ENGINEER FOR CLARIFICATION PRIOR TO BID OPENING.
SYMBOLS USED BUT NOT LISTED HERE SHALL BE DEFINED ELSEWHERE IN THE BID
RECEPTACLE
M
1 480V,277V,208V OR 120V MOTOR
CONDUIT CONCEALED IN CEILING OR WALL,
BENEATH FLOOR, OR UNDERGROUND
CONDUIT EXPOSED, UNLESS OTHERWISE NOTED
PANEL TOP : 6 AFF
PANEL TOP : 6 AFF
3P 30A
BOX CENTER : 2 AFF
BOX CENTER : 18" AFF
BOX CENTER : 4 AFF
BOX CENTER : 18" AFF
BOX CENTER : 4 AFF
1
PANEL TOP : 6 AFF
SM
208V, 2 POLE MANUAL STARTER WITH THERMAL OVER LOAD RELAY
AND RED PILOT LAMP
(RUSSELLSTOLL "ERSFH 8414" SERIES OR APPROVED EQUAL)
T THERMAL STARTER
AUXILIARY
COMBINATION VOICE & DATA OUTLET, 1 EACH
COMBINATION VOICE, DATA & VIDEO, 1 EACH
COMBINATION VOICE & DATA OUTLET, 1 EACH (CEILING MOUNTED)
(WALL MOUNTED : FL + 1-6")
(WALL MOUNTED : FL + 1-6")
SF 120V, 2 POLE MANUAL STARTER WITH THERMAL OVER LOAD RELAY
AND RED PILOT LAMP
WALL MOUNTED UNIT
S
SYMB. DESCRIPTION REMARKS
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
ABBREVATIONS
LEGEND &
DRAWING LIST
4C1
ELECTRICAL ABBREVATIONS ELECTRICAL SYMBOLS LEGEND
IM-E-001
DRAWING INDEX DRAWING INDEX
ELECTRICAL SPECIFICATIONS
CRITEIRA
CONTRACT DOCUMENT FOR ADDITIONAL
WHICH ARE PART OF THE ELECTRICAL
REFER TO THE ELECTRICAL SPECIFICATION
3- ROOM / FIXTURE TYPE / QTY LEGEND
INVERTER SOURCE OF POEWR (EBIS).
IS TO BE EQUIPPED WITH EMERGENCY BATT./
2-"e" DESIGNATION INDICATES THE FIXTURE
QUANITIES, VOLTAGES & MOUNTING.
FIXTURE COUNTING, VERIFYING FIXTURE
1- CONTRACTOR IS RESPONSIBLE FOR ALL
SPACE NAME
FIXTURE
TYPE
FIXTURE
QTY
LIGHTING FIXTURE SCHEDULE
325 0
FFX
32K
F54T5HO
6
10% THD
UNV,
1/42- EBH,
HUNG
PEND
305V
THRU
108V
UNV
E6LP
EB/2LS
UNV-1/4/
FBF-6-54HO
DAYBRITE
POWER
BATT.
UNSWITCHED
SELF-TESTING & ALARM
2-LAMP-1325 LUMEN,
BATTERY-INVERTER,
AS "FF" EXCEPT WITH AUTO.
SAME MANUFACTURER & TYPE
F
F
X
325 - - 0 32K
F54T5HO
6
10% THD
UNV,
1/42- EBH,
HUNG
PEND
2-LEVEL SWITCHING
10% UPLIGHT,
95% SPECULAR REFLECTOR,
INDUSTRIAL HI-BAY,
2x4, 6-F54T5HO FLUORESCENT
305V
THRU
108V
UNV
EB/2LS
UNV-1/4/
FBF-6-54HO
DAYBRITE FF
F
F
100
32K
F32T8
3
0
IN
LAY
FIC
EB101PS
10% THD
HBF
1/21, UNV,
277
120/
UNV
SELF-TESTING & ALARM
2-LAMP-1400 LUMEN,
BATTERY-INVERTER,
AS "FA" EXCEPT WITH AUTO.
SAME MANUFACTURER & TYPE
POWER
BATT.
UNSWITCHED
FAX
E5ST
1/21EB10R
UNV-2WC
3-32-3x6-AL
2-LP3-G-S
DAYBRITE
F
A
X
FA
100 - - 32K
F32T8
3
0
IN
LAY
FIC
1/21EB10R
UNV-2WC
3-32-3x6-AL
2-LP3-G-S
DAYBRITE
2-LEVEL SWITCHING
CELLS, WIREWAY COVERS,
TROFFER, 3x6 PARABOLIC
2x4, 3-T8, FLUORESCENT
EB101PS
10% THD
HBF
1/21, UNV,
277
120/
UNV
F
A
DESCRIPTION
LIGHTING FIXTURE
NOTES
MTG
#
REV
COLOR
& TYPE
# LAMPS
TYPE
BALLAST
ID
TAG
FIXT
VOLTS
PWR
INPUT
VA/EA
PWR
INPUT
MODEL
SERIES
MANUF.
#
NOTE
ITEM
SYMBOLS
GRAPHIC
GENERAL LIGHTING FIXTURE SCHEDULE
EMERGENCY EGRESS & EXIT SIGNS LIGHTING FIXTURE SCHEDULE
DESCRIPTION
LIGHTING FIXTURE
NOTES
MTG
#
REV
LAMPS
HEAD/
UNIT
TYPE
BATTERY
ID
TAG
FIXT
VOLTS
PWR
INPUT
VA/EA
PWR
INPUT
MODEL
SERIES
MANUF.
#
NOTE
ITEM
SYMBOLS
GRAPHIC
XC
0
MANUF
BY
LED
MANUF
PER
NI-CAD
277V
120/
5
POSITION
MUTI-
UNIV.
S-L-U-R-W-AD
SYMMETTRY I
CHLORIDE
SELF- TESTING & ALARM
HOUSING, UNVIERSAL MTG.,
ARROWS AS NEEDED, WHITE
BATTERY BACK-UP, RED LTRS,
EXIT SIGN, COMMERCIAL LED,
EXIT
PWR. SOURCE
UNSWITCHED
CONN. TO
XH
0
MANUF
BY
LED
MANUF
PER
NI-CAD
277V
120/
5
POSITION
MUTI-
UNIV.
WA-ICT-A
T-L-N-U-R-
TUFF-ACT
CHLORIDE
SELF-TESTING & ALARM
UNIVERSAL MTG.,
ARROWS AS NEEDED,
BATTERY BACK-UP, RED LTRS,
EXIT SIGN, HEAVY-DUTY LED,
EXIT
PWR. SOURCE
UNSWITCHED
CONN. TO
XZ
0
277V
120/
5
POSITION
MUTI-
UNIV.
HALOGEN
PAR 36
2-6V 6W
EXIT &
LED
MANUF
PER
CALCIUM
LEAD
R-WET
N2H-LED-2HC
NEMA
CHLORIDE
SELF- TESTING & ALARM
UNIVERSAL MOUNTING,
ARROWS AS NEEDED,
BATTERY BACK-UP, RED LTRS,
EXIT & 2-EGRESS LT HEADS,
EXIT SIGN, NEMA COMBO LED
EXIT PWR. SOURCE
UNSWITCHED
CONN. TO
X1
0
277V
120/
5
POSITION
MUTI-
UNIV.
HALOGEN
MR16
12W,
6 VDC,
TWO
25 WATT
6VDC
CALCIUM
LEAD
W-IC-TA-TD
S6-25L-H12
SYMMETTRY
CHLORIDE
& ALARM, TIME DELAY OFF
BATTERY WITH SELF-TESTING
WHITE, 2-HEAD UNIT,
COMMERCIAL ENCLOSED,
EMERG. EGRESS UNIT,
E
M
PWR. SOURCE
UNSWITCHED
CONN. TO
X2
0
277V
120/
5
POSITION
MUTI-
UNIV.
HALOGEN
36 PAR
50 W,
12 VDC,
THREE
250 WATT
12VDC
CALCIUM
LEAD
PN-3-IC-TA-TD
RN-2-25-HA
RHYNO
CHLORIDE
TIME DELAY OFF
& ALARM, GRAY HOUSING,
BATTERY WITH SELF-TESTING
NEMA ENCLOSED 3-HEAD UNIT,
EMERG. EGRESS UNT,
E
M
CONN. TO
UNSWITCHED
PWR. SOURCE
DESCRIPTION
LIGHTING FIXTURE
NOTES
MTG
#
REV
COLOR
& TYPE
# LAMPS
TYPE
BALLAST
ID
TAG
FIXT
VOLTS
PWR
INPUT
VA/EA
PWR
INPUT
MODEL
SERIES
MANUF.
#
NOTE
ITEM
SYMBOLS
GRAPHIC
GENERAL LIGHTING FIXTURE SCHEDULE
WB
0 MTD
WALL
INTEGRAL PHOTOCELL
CUT-OFF TYPE OPTICS,
CWTEMP BALLAST,
WALL PACK, MH LAMP,
WET-LOCATION, OUTDOOR,
HALIDE
METAL
400W
1-
CWA
START
PULSE
5T
480V
THRU
120V
5T
485
5T-PSC
MH/PS
WLR-400
DAYBRITE
VERIFY HTG.
ON WALL
MTD. HIGH
WA
0
CFL
42W
2-
WEATHER
COLD
MT
305V
THRU
108V
UNV
90 MTD
WALL
U-DB-PE
CSP-42C-D
DAYBRITE
INTEGRAL PHOTOCELL
CUT-OFF TYPE OPTICS,
CWTEMP BALLAST,
WALL PACK, 2-CLF LAMP,
WET-LOCATION, OUTDOOR,
TO DOOR
OR ADJACENT
MTD. ABOVE
F2
F
2
F2x
F
2x
32K
F32T8
2
0 65 SM
277V
120/
UNV
EB10PS
10% THD,
HBF
1/2, UNV,
SELF-TESTING & ALARM
2-LAMP-1400 LUMEN,
BATTERY-INVERTER,
AS "??" EXCEPT WITH AUTO.
SAME MANUFACTURER & TYPE
E5W
1/2-EB10R
2-32-UNV-
D-W-A-E
DAYBRITE
POWER
BATT.
UNSWITCHED
F1X
F1X
- - 32K
F32T8
2
0
F1
65 SM
NON-METAL HOUSING
WET LOCATION,
GASKETED ACRYLIC DIFFUSER,
ENCLOSED INDUSTRIAL,
1x4, 2-T8, FLUORESCENT
1/2-EB10R
2-32-UNV-
D-W-A-E
DAYBRITE
277V
120/
UNV
EB10PS
10% THD,
HBF
1/2, UNV,
F1
FUL
F
U
L
2-LEVEL SWITCHING
CLASS 100,000,
TROFFER, CLEAN ROOM,
2x4, 3-T8, FLUORESCENT
SELF-TESTING & ALARM
2-LAMP-1400 LUMEN,
BATTERY-INVERTER,
"FC" EXCEPT WITH AUTO.
SAME MANUF. & TYPE AS
100 - - 32K
F32T8
(3)
0
IN
LAY
FIC
EB101PS
10% THD
HBF
1/21, UNV,
277
120/
UNV
1/21EB10R
UNV-2WC
3-32-DB19
2-DCL-G
DAYBRITE
100
32K
F32T8
(3)
0
IN
LAY
FIC
EB101PS
10% THD
HBF
1/21, UNV,
277
120/
UNV
E5ST
1/21EB10R
UNV-2WC
3-32-DB19
2-DCL-G
DAYBRITE
POWER
BATT.
UNSWITCHED
- - 0
32K
CFL
32 WATT
(1)
MV
HPF
277V
120V
MV
HPF
35
IN CLG
FLUSH
H85
F126/32/42
CM8-U-
CAPRI
TRIM RING.
CLEAR REFLECTOR, CLG.
LOWIRIDESCENT
ELECTRONIC BALLAST,
VERTICAL, 1-CFL LAMP,
08 INCH DIA. DOWNLIGHT
HA
220 - - 0
HA
WIE GUARD & SAFTEY CABLE
POWER HOOK & LOOP
EP-PSM BALLAST, 65C TEMP,
24 INCH DIA., ADJUSTABLE
SEALED OPTICAL UNIT
HIGH-BAY INDUSTIRAL
START
PULSE
HALIDE
METAL
175WCMH
(1)
240/277
120/208
MT
HPF
EPM
EP
65C
HPF
& LOOP
HOOK
PEND
PB-TB-HP-LP
EP-PSM-65
MT-A17LGE
HBE-175-PSMH
INDUSTRA 4LG
DAYBRITE
220 - - 0
START
PULSE
HALIDE
METAL
175WCMH
(1)
240/277
120/208
MT
HPF
EPM
EP
65C
HPF
& LOOP
HOOK
PEND
X
HA
HAX
& LAMP
INTERGRAL POWER UNIT
DELAY OPTION, WITH
EXCEPT WITH QTZ. TIME
SAME MANUF. & TYPE AS "HA"
QTD
PB-TB-HP-LP
EP-PSM-65
MT-A17LGE
HBE-175-PSMH
INDUSTRA 4LG
DAYBRITE
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
LIGHTING FIXTURE CRITERIA
IM-E-002
AND NEWLAMPS INSTALLED.
REINSTALLED FIXTURES SHALL BE CLEANED,
WITH OWNER & ARCHITECT PRIOR TO REMOVAL.
DOCUMENT ANY DAMAGED OR INOPERABLE FIXTURES
FIXTURE, MARK & LABEL, REMOVE & STORE.
SHALL, BEFORE DEMOLITION, INSPECT EXISTING
REUSED AS MUCH AS POSSIBLE. CONTRACTOR
4- EXISTING LIGHTING FIXTURES ARE TO BE
& CRITERIA
SCHEDULE
FIXTURE
LIGHTING
LIGHTIG FIXTURES SHALL MATCH THE EXISTING TYPE.
5- ANY NEWLIGHTING FIXTURES IN AREAS OF EXISTING
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
CABLE SCHEDULE
NON VFD, BRANCH/ FEEDER SCHEDULE-D
TYPE XHHW WIRE-IN-CONDUIT, 3PH/ 4W/ G,
NON VFD, BRANCH/ FEEDER SCHEDULE-Y
TYPE XHHW WIRE-IN-CONDUIT, 3PH/ 4W/ G,
NON VFD, BRANCH/ FEEDER SCHEDULE
TYPE TC - Y CABLE, 3PH/ 4W/ G,
NON VFD, BRANCH/ FEEDER SCHEDULE
TYPE TC - D CABLE, 3PH/ 3W/ G,
SCHEDULE OF TRANSFORMERS - DRY TYPE
SCHEDULES
CABLE
IM-E-003
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
PURLIN
BEAM CLAMP, B-LINE
#B3055 SERIES OR
OTHER APPROVED SEE
NOTE 7
1/2 DIA THREADED
STEEL ROD
PURLIN
SUPPORT CHANNEL
SEE NOTE 2
PURLIN
1/4 MAX
BEAM CLAMP KINDORF
#E-781 OR OTHER
APPROVED
SUPPORT AT PURLIN
NTS
D1
SUPPORT BETWEEN PURLIN
NTS
D2
NOTE:
USE TRAPEZE HANGER SIMILAR TO CABEL TRAY SUPPORT
SYSTEM SHOWN ON DETAIL THIS SHEET, FOR CONDUIT
SIZE5 LATGER THAN 1"
1/2 DIA THEADED STEEL ROD
BUS DUCT
BUS PLUG
BUS PLUG
SUPPORT
FLANCE
BUS PLUG MOUNTING DETAIL
NTS
D3
1/2" THREADED
STEEL ROD
ADJUSTABLE BEAM CLAMP
KINDORF #E-160 OR OTHER
APPROVED SEE NOTE 5
PURLIN
SUPPORT AT PURLIN
NTS
D5
SWAY BRACE ATTRACHED TO
SUPPORT CHANNEL BETWEEN
PURLINS OR BAR JOIST
TYPICAL SWAY BRACE CONNECTION
NTS
D6
(SEE NOTE 12)
1/4 MAX
PURLIN
OR BAR JOIST
SUPPORT CHANNEL
BEAM CLAMP KINDORF
#E-781 OR OTHER
APPROVED
PURLIN
OR BAR JOIST
SWAY BRACE SECURE TO
BLDG STEEL (SEE
SPECIFICATION)
BEAM CLAMP
SWAY BRACE
ATTACHED TO
PURLIN OR BAR
JOIST
SEE PLAN FOR
ELEVATIONS
FINISHED FLOOR
BOTTOM CHORD OF TRUSS
SUPPORT CHANNEL
SEE NOTES
CABLE TRAY. SEE PLAN DWG
FOR SIZE. ELEVATION &
QUANTITY (TYP)
SQUARE WASHER & 2 HEX
NUTS (TYP)
HOLD DOWN
CLAMP (TYP)
SQUARE WASHER &
HEX NUT (TYP)
SUPPORT ROD SHALL EXTEND
MIN 1/2" AND MAX 1" BEYOND
HEX NUT
TYPICAL CABLE TRAY SUPPORTS
NTS
D7
1/2" DIA THREADED
STEEL ROD (TYP)
CONDUIT TO CABLE TRAY
NTS
D8 MOUNTING DETAIL
FASTEN #8 CU GROUND
TO CABLE TRAY
24" SIGNAL
CABLE TRAY
CONDUIT BUSHING
WITH GROUND CLAMP CLAMP RIGID CONDUIT
TO CABLE TRAY
RIGID STEEL
CONDUIT
PURIN
OR BEAM
BEAM CLAMP
3/8" HANGER ROD
CONDUIT HANGER
CONDUIT 1"
& SMALLER
ANCHOR CLIP
SUPPORT AT PURLIN FOR
NTS
D9 CONDUIT 1" AND SMALLER
NOTES:
USE TRAPEZE HANGER SIMILAR TO CABLE TRAY
SUPPORT SYSTEM SHOWN ON DETAIL THIS
SHEET. FOR CONDUIT SIZE5 LARGER THAN 1"
CABLE TRAY - SEE PLAN FOR LOCATION
AND ELEVATION
TYPICAL CABLE TAP BOX
NTS
D4 CABLE TERMINATION DETAIL
SUPPORT ROD TO BE
ANCHORED TO ROOF
PURLINS OR MISC STEEL
CABLE TAP BOX
CABLE TERMINATOR
CABLE CLAMP
SUPPORT CHANNEL (TYP)
CABLE(TYPICAL)
BUSDUCT SEE PLAN FOR
LOCATION AND ELEVATION
PROVIDE SWAY BRACE ON ALL
TAPBOXES. SWAY BRACE
SHALL BE PARALLEL TO
CABLE ENTRY
SUPPORT AT PURLIN FOR
NTS
D10 CONDUIT 1" AND SMALLER
NOTE:
USE TRAPEZE HANGER SIMILAR TO CABLE TRAY
SUPPORT SYSTEM SHOWN ON DETAIL THIS
SHEET. FOR CONDUIT SIZE5 LARGER THAN 1"
CONDUIT 1"
& SMALLER
PARALLEL PIPE AND
CONDUIT BEAN CLAMPS
PURLIN
4 - 0"
ROOF TRUSS
W
8 P
U
R
LIN
ROOF TRUSS
TRAPEZE SUPPORT
(TYP)
NTS
D12 TYPICAL CABLE TRAY SUPPORT PLAN
(BUS DUCT SUPPORT SIMILAR)
HEADER STEEL (TYP)
D
O
ADDITIONAL TRAPEZE SUPPORTS &
HEADER STEEL ON CABLE TRAY
HORIZONTAL BENDS AS REQD BY
ELECTRICAL CODE
R-36"
OR 48"
R-36"
OR 48"
LAMINATED ALUMINUM
BONDING JUMPERS ON
BOTH SIDE OF LADDER
SET GAP ACCORDING
TO INSTALLATION
TEMPERATURE
NTS
D11
DETAIL CABLE TRAY EXPANSION JOINT
AND GROUND BOUNDING JUMPER
EXPANSION JOINT
CABLE TRAY
SIDE RAIL
SPLICE PLATE
ANSI D - SCALE: NONE = 1-0"
GENERAL DETAIL-1
- EP
1
NTS
D13
CODE
MAY BE STACKED PER
CABLES 3/0 & SMALLER
SIZED PER CODE
BONDED TO CABLE TRAY,
CONTINOUS GROUND,
G
NOT STACKED
IN SINGLE LAYER,
CABLES 4/0 & LARGER
OF IMPOSED LOADS.
RODS RATED FOR 150%
STRUTURAL THREADED
LOCK-NUTS, PER MANUF.
WASHERS & DOUBLE
WEIGHTS & LOADS
FOR 150% OF ACTUAL
CABLE TRAY, SIZED
VENTILATED TYPE
CABLES 3/0 & LESS
392.9, COLUMN 1
WIDTH PER NEC TBL.
CABLES & LARGER
CABLE ODS, 4/0
WIDTH SUM OF
ATTACHEMENTS.
ENGINEER USING APPROVED
MEMBERS PER STURCTRUAL
ATTACH TO STRUCTURAL
AND PER CODES.
BRACING PER ZONE
PROVIDE SISMEIC
MINIMUM
2 IN. SPACE
OF WIDTHS + 10% MIN.
TOTAL WIDTH IS SUM
TYPICAL POWER CABLE TRAY CABLE ARRANGMENT
C C C C C C C
C C
C
PER NEC 392 CABLE TRAYS & NEIS/NECA/NEMA 105
PRODUCTS WITH SIZING & LOADING DATA.
PROVIDE COMPLETE SUBMITTAL OF LAYOUTS,
WITH ALL MATCHING COMPONENTS & HARDWARE,
CABLES, RATED FOR 150% OF ACTUAL WEIGHT LOADS.
NEMA CLASS C (100 LBS/FT), ONLY 600 VOLT RATED TC
24, 30 OR 36 INCH WIDE, 6 INCH NEMA LOAD DEPTH,
VENTILATED LADDER TYPE, 9 INCH RUNG SPACING,
DETAIL BASED ON STRUCTURAL ALUMINUM CABLE TRAY,
SHALL BE LIMTED TO LOADING PRODUCING A MAXIMUM MOMENT NO CREATER THAN 200 FT-LBS WITH A
MAXIMUM SPAN OF 8-0"
SHALL BE LIMTED TO LOADING PRODUCING A MAXIMUM MOMENT NO CREATER THAN 200 FT-LBS WITH A
MAXIMUM SPAN OF 8-0"
HEADER STEEL DEFLECTION SHALL BE LIMITED TO NO GREATER THAN 1/240, WHERE I EQUALS THE SPAN IN
INCHES.
TRAPEZE OR CONDUIT TRAPEZE SUPPORT MEMBERS SHALL NOT SPAN CREATER THAN 48 INCHES BETWEEN
HANGER RODS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
FOR PURLINS SPANS THAT HAVE MULTIPLE ECCENTRIC CLAMPED ATTACHMENTS, ALTERNATE THE SIDE OF THE
ATTACHMENT TO THE PURLIN TO COUNTERBALANCE THE LOAD
HEADER STEEL SUPPORTING BUS DUCTS OR CABLE TRAYS SHALL BE CONSIDERED AS FULLY LOADED AND
SHOULD NOT BE USED TO SUPPRT ANY ADDITOINAL ELECTRIC LOADS
THE CONTRACTOR SHALL CALCULATE THE ACTUAL MAXIMUM MOMENT AND MAXIMUM DEFLECTION ON HEADER
STEEL TO INSURE THAT THE MEMBER SELECTED MEETS THE REQUIREMENTS OF NOTES #1, 2, & 3
SUPPORT CHANNEL SHALL BE 2- 15/8" x 1.5/8" COLD FORMED CONTINUOUS SLOTTED CHANNEL BACK TO
BACK WHEN HANGER TRAY IS 24" WIDE OR LARGER & STACKED MORE THAN TWO (2) HIGH
CONTRACTOR SHALLSUBMIT ALL CALCULATIONS FOR HANGING UTILITIES AND DETAILED METHOD OF HANGER
SUPPORT TO OWNER REPRESENTATIVE FOR APPROVAL PRIOR TO INSTALLATION OF EQUIPMENT. THE CALCULATIONS
SHALL BE MADE. CHECKED. APPROVED AND CERTIFIED BY A PROFESSIONAL ENGINEER REIGSTERED IN THE STATE
OF GEORGIA.
ALL HANGER RODS SHALL BE 1/2" THREADED STEEL MINIMUM, UNLESS OTHERWISE NOTED
SUPPORT ALL BUS PLUG 200 AMPS AND LARGER WITH 1/2" DIAMETER THREADED RODS PROVIDE (1) ROD FOR
200 AMP BUS PLUGS. AND (2) RODS FOR BUS PLUGS LARGER THAN 200 AMP
1 5/8" x 1 5/8" COLD FORMED CONTINUOUS SLOTTED CHANNEL USED AS A CABLE TRAY TRAPEZE, BUS DUCT
1 5/8" x 3 1/4" COLD FORMED CONTINUOUS SLOTTED CHANNEL. USED AS HEADER STEEL BETWEEN PURLINS.
1 5/8" x 3 1/4" COLD FORMED CONTINUOUS SLOTTED CHANNEL. USED AS HEADER STEEL BETWEEN PURLINS.
NOTES-TYP. FOR BUS DUCTS, CABLE TRASY & CONDUIT SUPPORTS
01
DETAILS
GENERAL
IM-E-004
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
NTS
D13
2
-0
"
NTS
D17
ANCHOR
BOLTS
NTS
D14
1 - 0" 4 - 6" 1 - 0" 4 - 6"
20A PLUG CONNECTOR
SUPPLIED WITH FIXTUBE
COORDINATE WITH OWNERS
REPRESENTATIVE
20A CONNECTOR
SUPPLIED WITH FLEXIBLE
WIRING SYSTEM
FLEXIBLE WIRING
SYSTEM
MODULAR WIRING SYSTEM TEE (PROVIDE WITH
CAP WASHER WITH FLEXIBLE
WIRING SYSTEM
3/C #16 "SO" CORD AND
PULG
PURLIN OR MISC STEEL
WHERE REQUIRED
ROOF LINE
CABLE CLAMPS OR
TIE(TYP)
J BLOT TYPE
BEAM CLMAP
(TYP FOR 2)
COIL 10 OF FLEXIBLE
WIRING TO ALLOWFUTURE
RELOCATION OF FIXTURE
CHAIN, DOUBLE LOOP COIL
CHAIN HOT GALVANIZED
(TRADE SIZE 2/0) ANCHOR
TO STRUCTURAL STEEL
ABOVE
FLUORESCENT FIXTURE
NTS
D16
2" INSULATED METAL
PANEL (BUILDING EXTERIOR)
12" x 12" x 1/8"
STEEL PLATE
JUNCTION BOX
TUBE STEEL
DOOR FRAME
TO ADJACENT
LIGHT FIXTURES
3/4 " CONDUIT
1/2" CONDUIT
JUNCTION
BOX
CAPTIVE GASKET
TUBE STEEL
DOOR FRAME
DOOR OPENING
SA
OUT SIDE BUILDING
WALL
RIGID STEEL
CONDUIT
FIXTURE SUPPORT
PLATE
FIXTURE SUPPORT
PLATE
EXIT SIGN WHERE
SHOWN ON PLAN
12 GA SHEET METAL, SIZED AND BENT
TO SUIT FOR SUPPORT OF FIXTURE
ATTACH TO TOP SIDE ABOVE DOOR
FRAME AS REQUIRED
NOTE:
SEAL ALL
PENETRATIONS
WATER-TIGHT
4 - 6" 1 - 0" 4 - 6" 1 - 0"
TYPICAL LOW/HIGH BAY HID FIXTURE MOUNTING DETAIL D15
BASE BID - CONDUIT PENDANT MOUNT
20A PLUG CONNECTOR SUPPLIED WITH FIXTUBE COORDINATE WITH OWNERS REPRESENTATIVE
20A CONNECTOR SUPPLIED WITH FLEXIBLE WIRING SYSTEM
PURLIN OR MISC STEEL WHERE REQUIRED "J" TYPE BEAM CLAMP WITH 3/8" ROD (TYPICAL)
SAFETY CHAIN SUPPORTED FROM BEAM CLAMP SUPPLIED WITH FIXTURE
COIL 10 OF FLEXIBLE WIRING TO ALLOW FUTURE RELOCATION OF FIXTURE
SWIVEL JOINT WITH STUD (KINDORF #H-261 OR EQUAL), DOUBLE NUT AT HANGER ROD CONNECTION
1/2" THREADED STEEL ROD LENGTH TO SUIT
FLEXIBLE WIRING SYSTEM
3/C #16 "SO" CORD AND PULG
BOTTOM CHORD OF TRUSS
SAFETY HOOK SUPPLIED WITH FIXTUBE
SAFETY CHAIN SUPPLIED WITH FIXTURE
CABLE CLAMPS OR TIES
ROOF LINE
1/2"
FIXTURE
MODULAR WIRING SYSTEM TEE (PROVIDE WOTH CAP WHERE FUTURE FIXTURE IS INDICATED ON PLAN)
4 - 6" 1 - 0" 4 - 6" 1 - 0"
MANDATORY ALTERNATE - CHAIN HANG
20A PLUG CONNECTOR SUPPLIED WITH FIXTUBE COORDINATE WITH OWNERS REPRESENTATIVE
20A CONNECTOR SUPPLIED WITH FLEXIBLE WIRING SYSTEM
PURLIN OR MISC STEEL WHERE REQUIRED
MODULAR WIRING SYSTEM TEE (PROVIDE WITH CAP WHERE FUTURE FIXTUBE IS INDICATED ON PLAN)
SAFETY CHAIN SUPPORTED FROM BEAM CLAMP SUPPLIED WITH FIXTURE
COIL 10 OF FLEXIBLE WIRING TO ALLOWFUTURE RELOCATION OF FIXTURE
FLEXIBLE WIRING SYSTEM
3/C #16 "SO" CORD AND PULG
BOTTOM CHORD OF
SAFETY HOOK SUPPLIED WITH FIXTUBE
SAFETY CHAIN SUPPLIED WITH FIXTURE
1/2"
FIXTURE
TRUSS
ANSI D - SCALE: NONE = 1-0"
GENERAL DETAIL-2
- EP
1
LIG FIXTURE
1
FLEXIBLE CONDUIT
FLEXIBLE CONDUIT
RACE WAY
RACE WAY
NTS
D15A
OUTLET BOX
BOLT & NUT
OUTLET BOX
BOLT & NUT
PURLIN OR MISC STEEL
WHERE REQUIRED
PURLIN OR MISC STEEL
WHERE REQUIRED
LIG FIXTURE SUPPORT
LIG FIXTURE
TYPICAL OUTDOOR WALL
MOUNTING LIGHT FIXTURE DETAIL
LIGHTING WALL MOUNTING DETAIL
EXTERIOR PEDESTRIAN DOOR
TYPICAL FLUORESCENT
FIXTURE DETAIL - RACEWAY MTD
TYPICAL FLUORESCENT
FIXTURE DETAIL - CHAIN HUNG
TYPICAL INSTALLATION DETAIL OF PEDESTRIAN
DOOR LIGHTING FIXTURE & EXIT SIGN
02
DETAILS
GENERAL
TO MATCH PLUG PROVIDED WITH FIXTURE
A 15A, 277V TWIST-LOCK RECEPTACLE
FED FROM EMERGENCY POWER, PROVIDE
WHERE TYPE "FA" OR "FB" LIGHTING FIXTURES ARE
NOTES
IM-E-005
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
NTS
D21
RIGID STEEL CONDUIT
SIZE AS NOTED ON
RISER DIAGRAM
RIGID STEEL CONDUIT
TO DISTRIBUTION
CABINET. SIZE AS
NOTED ON RISER
DIAGRAM MES CABLE TRAY
(SEE PLANS FOR
CABLE TRAY SIZE)
CABLE TRAY DIVIDER
CONDUIT BUSHING WITH
"0" RING INSIDE CABINET
DISTRIBUTION CABINET
CONDUIT
CLAMP
CONDUIT
BUSHING
CABLE TRAY
BARRIER STRIP
CONDUIT
BUSHING
CONDUIT
CLAMP
NTS
D20
CABLE TERMINATOR
SWITCHGEAR
TOP OF
ON PLANS
NOTED
SIZE AS
CABLE TRAY
* BUS DUCTS AND CONDUITS SIMILAR
NTS
D22
ELEVATION (TYP)
SEE PLAN FOR
SUPPORT (TYP)
CABLE TRAY SYSTEM
CABLE TRAY
SYSTEM
INSIDE
BUILDING
CABLE SEAL
CABLE TRAY SYSTEM
TIE BETWEEN BUILDINGS
# 4/0 CU GROUND CABLE
(SEE SPEC TYP)
CABLE TRAY AND TRANSIT
CONNECT GROUND CABLE TO
TRAY SYSTEM (TYP)
TO OTHER CABLE
PLATE & STEEL CHANNEL
SYSTEM "SF FRAME" MOUNTED ON STRUCTURAL
MULTI-CABLE TRANSIT (MCT) FRAME OR ROX
ARCHITECTURAL TRADE
COORDINATE WITH
WALL OPENING
THE PLANS
OR AS SHOWN ON
OUTSIDE BUILDING
CABLE TRAY SYSTEM
BLOCK WALL
FIRE WALL
8" 6" 1 - 0"
NTS
D23
FINAL FLOOR OR
WORK PLATFORM
PROVIDE STANDARD 4 11/16" SHEET
STEEL JUNCTION BOX WITH COVER
IN TRUSS SPACE AT EVERY COLUMN
ALONG 120V RECEPTACLE CONDUIT
RUN FOR FUTURE 120V RECEPTACLE
OUTLET BY OWNER
BUILDING
COLUMN
120V
RECEPTACLE
BUILDING
COLUMN
UNISTRUT
16"
CONDUIT
BOTTOM CHORD
OF TRUSS
TO OTHER RECEPTACLE
OR POWER SOURCE
COL
PROVIDE JUNCTION BOX
FOR EACH CONDUIT DROP
TO 120V RECEPTACLE
COL
TO OTHER RECEPTACLE
J J
NTS
D24
TO POWER PANEL AS NOTED
PRIMARY CONDUIT & WIRE
& 5" x 6.7# STEEL CHANNELS
3" x 3" x 1/4" STEEL ANGLES
480 - 120/208V 3PH,4W
DRY TYPE TRANSFORMER
KVA SIZE AS NOTED & WIRES TO RECEPTACLE
SECONDARY CONDUIT
PANEL AS NOTED
HANGER ROD
ROOF
SUPPORT CHANNEL
BOTTOM CHORD OF TRUSS
COL
NTS
D25
SUPPORT CHANNEL
HANGER ROD (TYP)
#6 BARE STRANDED
COPPER GROUND WIRE
FILLET WELD PER AISC STANDARDS
BY ELECTRICAL CONTRACTOR (TYP)
3" x 3" x 1/4" STEEL ANGLES
& 5" x 6.7" STEEL CHANNELS
DRY TYPE TRANSFORMER
480 - 120/208V,3PH, 4W
KVA SIZE SIZE AS NOTED
NTS
D26
TO COLUMN FLANGES. PLATE SHALL
1/4" THICK STEEL PLATE BOLTED
AN EQUIVALENT AMOUNT TO THE
PROTRUDE BEYOND COLUMN EDGES
EXTEND FROM THE BOTTOM OF THE
PANEL ITSELF. THIS PLATE SHALL
PANEL TOTHE TOP OF THE PANEL
MOUNTING DETAIL
FOR TRANSFORMER
TO JUNCTION BOX
PANEL FEEDER DOWN
DIVISER IF OVER 27 WIRES)
WIREWAY (PROVIDE THROUCH
OF WORKING PLATFORM
FINISHED FLOOR OR TOP
PANEL
COLUMN TYPE
COLUMN
BUILDING
BRANCH
REQUIRED
CIRCUITS AS
BOTTOM
TRUSS
CHORD OF JUNCTION BOX WITH
STRIP
NETURAL BAR, TERMINAL
MAX
6 - 6"
COL
CONDUIT
UNITSTRUT
COLUMN
UNISTRUT
INSTALL ASSEMBLY INSIDE
COLUMN WEB
60A-3P MAIN DISCONNET
SWITCH @45A
DOOR HANDLE
120V OUTLETS
BREAKER/GFCI PROTECTION TO
SPEC
POWER OUTLET 60A,
600V
4
8
"
FIN FLOOR OR WORK
PLATFORM
BUILDING
NTS
D27
ANSI D - SCALE: NONE = 1-0"
GENERAL DETAIL-3
- EP
1
COMBINED INTERLOCKED TRANSFORMER
DISCONNECT MOUNTING DETAIL
120V RECEPRACLE TYPICAL WIRING CABLE TRAY CONDUIT TERMINATION DETAIL
MES CABLE TRAY -
TERMINATION AT METAL CLAD SWITCHGEAR
TYPICAL TOP ENTRY AND CABLE
TYPICAL SECTION - CABLE
PENETRATION THRU FIRE WALL MOUNTING DETAIL
TYPICAL TRANSFORMER
MOUNTING DETAIL
COLUMN TYPE PANEL
SECTION
03
DETAILS
GENERAL
IM-E-006
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
GROUND CONNECTION
ANNUNCATOR RELAY
AMMETER
AMMETER SWITCH
POWER FACTOR METER
WATT - HOUR METER
WATT - HOUR DEMAND METER
KILOWATT - HOUR METER
VOLT METER
VOLT METER SWITCH
CURRENT LIGHTING FUSE
CIRCUIT BREAKER
SINGLE THROWSWITCH
LIGHTNING ARRESTOR
POWER TRANSFORMER
POTENTIAL TRANSFORMER
VACUUM CIRCUIT BREAKER
15 KV CLASS MV DRAW-OUT
DRAW-OUT CIRCUIT BREAKER
SECONDARY SUBSTATION
CIRCUIT MONITORING UNIT(S)
480V SECONDARY SUBSTATION
CM
30
47
49T
A
AS
PF
52
VM
VS
CLF
51G
50/
51
50/
51N
50/
VOLTAGE RELAY
PHASE SEQUENCE
THERMAL RELAY
TRANSFORMER
51-AC TIME OVERCURRENT
50-INSTANTANEOUS O.C./ RATE-OF-RISE
51G- GROUND TIME OVERCURRENT
50-INSTANTANEOUS O.C./ RATE-OF-RISE
51-NEUTRAL TIME OVERCURRENT
50-INSTANTANEOUS O.C./ RATE-OF-RISE
CURRENT TRANSFORMER
KWH
WHD
WH
#3/0 G TO
BLDG STEEL
#2 CU TO
TELOC FRND
#3/0 GRND TO
F.P ETR. MAIN
(IF PRESENT)
INSULATOR
TAG/LABEL EACH
CABLE WITH TYPE
GROUND CONNECTION
#3/0 G T MAIN
SERVICE EQUIP.
SERVICE EQUIPMENT
SERVICE EQUIPMENT
GROUNDING ELECTRODE CONDUCTOR
SERVICE EQUIPMENT
GROUND BUS
SEE ONE-LINE & SPECS
#4 CU GRND TO
SLAB REBAR
"MGB" LABEL
ON WALL
BELOWBUS
ALL GRND.
CONDUITS
PVC 0.75"
MINIMUM
#3/0 GRND TO
CWMAIN
#4 GRND TO
GRND ROD FIELD
#3/0 GRND TO
GRND RING (IF PRESENT)
INSULATED GROUND BAR
1/4"Tx4"Hx32"L CU, PREDRILLED
MATCHING HARDWARE, 2-HOLE
COMPRESSON LUGS. ERICO
PRODUCTS OR EQUAL.
WALL BRACKE
NEUTRAL BUS
NEUTRAL GROUNDING RESISTOR
ONE-LINE DIAGRAM SYMBOLS
& NOTES
SYMBOLS
ONE-LINE
IM-E-100
ONE-LINE GENERAL ELECTRICAL NOTES
ORIGINAL CABLE SCHEDULE
SERVICE GROUNDING DETAIL
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
ARCH D - SCALE: NONE = 1-0"
OVERALL PLAN 1
E
ASSEMBLY
THETA NU ENGINE SHOP
..
627.34
303.67
627.34
515.33
WELDING
515.33
ENERGY CENTER
PAINT
2 2 6 12 2 6 3 2 2 6 2
SUBSTATION
2 2 6 12 2 6 3 2 2 6 2
230KV TRANSMISSION LINE
1 2 - 0 " X2 6 - 0 "S W I T C H H O U S E P U L LB O X
APC
OFFICE
STAMPING
821.0000
WASTE WATER
TREATMENT PLANT
201.91 33047 .625 REBAR SET/ANGLE PT. 201.91 1059 ANGLE POINT; 0
230KV TRANSMISSION LINE
TRUCK SCALE
BRICK
201.91 33047 .625 REBAR SET/ANGLE PT. 201.91 1059 ANGLE POINT; 0
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00
16+00
17+00
18+00
19+00
20+00
21+00
22+00 23+00
24+00
25+00
26+00
27+00
28+00
29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 46+00 47+00 48+00 49+00 50+00 51+00 52+00 53+00 54+00 55+00 56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00 64+00 65+00 66+00 67+00 68+00 69+00 70+00 71+00 72+00 73+00 74+00 75+00
76+00
77+00
78+00
79+00
80+00
81+00
82+00
83+00
84+00
85+00
86+00
87+00
88+00 89+00 90+00 91+00 92+00 93+00 94+00 95+00 96+00 97+00 98+00 99+00 100+00 101+00 102+00 103+00 104+00 105+00 106+00
106+55.96
PC = 15+02.04
PCC = 16+69.30
PT = 18+65.94
PC = 21+16.01
PT = 28+89.08
PC = 74+85.08
PT = 82+56.33
PC = 85+04.57
PCC = 87+02
PT = 88+69.27
START STA: -0+54.29
0+00 1+00 2+00
3+00
4+00
5+00
6+00
7+00 8+00 9+00
END STA: 9+35.33
PC = 1+90.71
PT = 3+08.52
PC = 5+72.52
PT = 6+90.33
STA: 22+60.76
BUILDING
INSPECTION
6279 s.f.
E: 501002.5595 N: 647024.0986
E: 502918.8762 N: 647045.4693
E: 504163.8414 N: 647059.8160
11340.00
1560.00
E: 500933.9201 N: 647138.6468
14
11340.00
E: 500998.5240 N: 648083.6468
1560.00
E: 500999.5949 N: 647953.6513
R180.00
B O X P U L L
S W I T C H H O U S E 2 6 - 0 " 1 2 - 0 " X
230KV TRANSMISSION LINE
2 2 6 22 2 6 3 2 2 6 12 2 6 22 2 6 3 2 2 6 1
336
336
1248.78
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23
1 2 3 4 5 6 7 8 9 10 11 12
24 25 26 27 28 29 30 31 32 33 34 35 36
14 15 16 17 18 19 20 21 22 23
37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 57
13
2
58
1
B
B D
10
20
B.1 D.7
G
3
20
B
10
L
L E
8
C K
B
Cart
Tram
Bus
Tram Tram Cart
12
16
306,036.56 sq ft
8601.36 py
179,578.31 sq ft
5047.17 py
331,196 sq ft
9307.71 py
52,272 sq ft
1469.02 py
831,488 sq ft
23,369.53 py
359,424 sq ft
108,725 py
THETA ENGINE
3
10 X 35 5 IN. YELLOWSTRIPE
DUMPSTER
PARKING NO
DUMPSTER D U M P S T E R
D U M P S T E R
DUMPSTER
D U M P S T E R D U M P S T E R
DUMPSTER
D U M P S T E R
DUMPSTER
D U M P S T E R
DUMPSTER
PARKING NO 1 2 4 5
D U M P S T E R DUM PSTER D U M P S T E R
DUMPSTER 21 DUMPSTER D U M P S T E R 3
DUMPSTER
DUMPSTER
4
349,440 sq ft
9,821.25 py
STORAGE
Tram
TOWER
TANK FARM
TRAILER AREA
COOLANT
DRUM
SECURITY
BUILDING
35.00 10.00
TRAILER AREA
MODIFICATION
701
701
703 703 707 708 708
711
712 713
301 (FUTURE)
601 601
614 614
602 603602 605 605 605 607 401
616 901
608
609 611 610
612
TRUCK PAD
STORM DRAIN TIE IN 201 202 203
613 3-0" HIGH CONTAINMENT WALL
615 ELECTRICAL LAV/CONTROL
606 704
702
603
604
WALLS CONTAINMENT 3-9" HIGH
902 719
701
617 601 204 604
718
BY HMMA TIE-IN #2 SEWER
BY HMMA TIE-IN #1 SEWER
716 102 102
101
101
101 BY HMMA PIPES WASTEWATER
SUMP STORMWATER 3x3SUMP BUILDING 709
710 DOOR ROLL-UP
DOOR ROLL-UP
PIPE BY HMMA E-COAT WASTE LOCATION OF
714 SUMP SUMP 715
1
SITE PLAN- POWER DISTB.
1000 500 01 IN = 200 FT
SHOP- SEE DETAILS
FOR EXISTING THETA NU ENGINE
NEW- SUBSTATION LOCATION
EXISTING IS INADEQUATE
PROVIDE ADDITIONAL CABLE TRAY IF
CAPACITY FOR NEWADDITIONAL CABLES.
HAS ADEQUATE SPACE AND STURCTURAL
VEIRFY EXISTING CABLE TRAY SYSTEM
EXISTING IS INADEQUATE
PROVIDE ADDITIONAL CABLE TRAY IF
CAPACITY FOR NEWADDITIONAL CABLES.
HAS ADEQUATE SPACE AND STURCTURAL
VEIRFY EXISTING CABLE TRAY SYSTEM
359,424 SQ. FT
INTERIOR MODIFICATIONS
THETA NU ENGINE SHOP
- -FIELD VERIFY EXISTING CABLE CONDITION
- -FIELD VERIFY EXISTING CABLE RATINGS
- -FIELD VERIFY CABLE WT. CAPACITY
- -FIELD VERIFY CABLE TRAY SIZE
- -FIELD VERIFY EXISTING ROUTE
1- PRIOR TO START OF WORK:
DISTRIBUTION
POWER
SITE PLAN
IM-E-101
OWNER, ARCHITECT & ENGINEER.
& COPY FINAL COMPLETED TESTS RESULTS TO
SHALL CERTIFY COMPLIANCE & TEST RESULTS
CABLE SHALL BE REPLACED. TESTING FIRM
QUALIFIED TESTING FIRM. ANY FAILED TEST
BY CABLE MANUFACTURER BY AN INDEPENDENT
PERFORMED ON EACH CABLE AS DIRECTED
MEDIUM VOLTAGE CABLE TEST SHALL BE
ENERGIZING CABLES (BOTH EXISTING & NEW),
2- AFTER CABLE INSTALLATION & BEFORE
ASSURE NEW CABLES MATCH EXISTING.
EXISTING CABLE TYPE & RATING TO
NU ENGINE SHOP. FIELD VERIFY
(1) 3-1C, #2/0 CABLES TO THETA
#4G IN PARRALLEL WITH EXISTING
TYPE MV-105 EPR MV CABLE & (1)
NEW- 2 SETS 3-1/C, CU, #2/0, 15KV,
ASSURE NEW CABLES MATCH EXISTING.
EXISTING CABLE TYPE & RATING TO
NU ENGINE SHOP. FIELD VERIFY
(1) 3-1C, #2/0 CABLES TO THETA
#4G IN PARRALLEL WITH EXISTING
TYPE MV-105 EPR MV CABLE & (1)
NEW- 2 SETS 3-1/C, CU, #2/0, 15KV,
ASSURE NEW CABLES MATCH EXISTING.
EXISTING CABLE TYPE & RATING TO
NU ENGINE SHOP. FIELD VERIFY
(1) 3-1C, #2/0 CABLES TO THETA
#4G IN PARRALLEL WITH EXISTING
TYPE MV-105 EPR MV CABLE & (1)
NEW- 2 SETS 3-1/C, CU, #2/0, 15KV,
NOT TO EXCEED 650 AMPS.
CONTRACT) VEIRFY WITH HMMA.
PROTECTION IS BY HMMA (NOT IN THIS
CABLE TERMINATION & OVER-CURRENT
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
52
51
50/
51N
50/ CM
1200AF
200AT
13800/120V
52
51
50/
51N
50/ CM
1200AF
52
51
50/
51N
50/ CM
52
51
50/
51N
50/ CM
1200AF 1200AF
E3-4 E3-3 E3-2 E3-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(2)
(3)
GF
Y
49T 30
86
E2-4 E2-3 E2-2 E2-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
E1-6 E1-5 E1-4 E1-3 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
INDICATOR
(3)
E1-2 E1-1
Y
2000/2667KVA
13.8KV-480/277V
OIL TYPE
TRANSFORMER
E1-7
1200A, 15KV DISTRIBUTION SWITCHGEAR
480V SUBSTATION E - LV - 4
COOLANT OIL TRANSFORE(EXISTING)
SEE DWG. NO. MI-E-307
480V SUBSTATION E - LV - 3
480V SUBSTATION E - LV - 2 480V SUBSTATION E - LV - 1
3-1/C #1/0 & 1#4(G) 15 KV WITH IN CABLE TRAY
3-1/C #1/0 & 1#4(G) 15 KV WITH IN CABLE TRAY
3-1/C #1/0 & 1#4(G) 15 KV WITH IN CABLE TRAY
3-1/C #1/0 & 1#4(G) 15 KV WITH IN CABLE TRAY
ELECTRICAL LEGEND NOTES
1
IM-E-102
MV SUBSTATION 1-LINE BEFORE
NO SCALE
1-LINE BEFORE
MV SUBSTATION
CENTER.
EPR MV CABLE & (1) #4G FROM 15KV OCP AT ENERGY
VERIFY EXISTING (1) 3-1C, CU, #2/0, 15KV TYPE MV-105
EMV1
EMV4
SEE ONE-LINE GENERAL ELECTRICAL NOTES
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
2
1 1 1
CHANGED AND NOWA 3200 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
3
CHANGED AND NOWA 2000 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
4
5
6
CHANGED AND NOWA 800 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
CHANGED AND NOWA 800 AMP FRAME.
THE ORIGINAL 1600 AMP FRAME OCP HAS BEEN
ADDITIONAL 800AF OCP DEVICE WAS ADDED.
THE ORIGINAL GEAR HAS BEEN CHANGED, AND
V
E
R
IF
Y
A
T
2
0
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
8
0
0
A
T
8
0
0
A
F
V
E
R
IF
Y
A
T
2
0
0
0
A
F
3 4
1
2
0
0
A
T
1
6
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
5 5
INDICATOR
DETECTOR &
GROUND-FAULT
INDICATOR
DETECTOR &
GROUND-FAULT
INDICATOR
DETECTOR &
GROUND-FAULT
BEFORE
ELV1-EXIST
BEFORE
ELV2-EXIST
V
E
R
IF
Y
A
T
3
2
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
S
P
A
C
E
1
6
0
0
A
F
2 2
BEFORE
ELV3-EXIST
V
E
IR
F
Y
A
T
3
2
0
0
A
F
1
2
0
0
A
T
1
6
0
0
0
A
F
S
P
A
C
E
1
6
0
0
0
A
F
2 2
OCP DEVICE
ONLY- NO
SWITCH
1200 AF
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
# #
2
5
0
0
A
T
3
2
0
0
A
F
2
5
0
0
A
T
3
2
0
0
A
F
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
52
51
50/
51N
50/ CM
1200AF
200AT
13800/120V
52
51
50/
51N
50/ CM
52
51
50/
51N
50/ CM
52
51
50/
51N
50/ CM
3-1/C #1/0 & 1#4(G) 15 KV WITH IN CABLE TRAY(EACH)
1200AF
E3-4 E3-3 E3-2 E3-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(2)
(3)
GF
Y
49T 30
86
GROUND FAULT
DETECTOR &
INDICATOR
E2-4 E2-3 E2-2 E2-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
E1-6 E1-5 E1-4 E1-3
1200 AT
3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
(3)
E1-2 E1-1
52
51
50/
51N
50/ CM
1200AF
52
51
50/
51N
50/ CM 51
50/
51N
50/ CM
1200AF
PROVISION
51
50/
51N
50/ CM
BLANK
1200AF
E5-4 E5-3 E5-2 E5-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
E6-4 E6-3 E6-2 E6-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
1200AF 1200AF
Y
2000/2667KVA
13.8KV-480/277V
OIL TYPE
TRANSFORMER
3-1/C #1/0 & 1#4(G) 15 KV WITH IN CABLE TRAY(EACH)
3-1/C #1/0 & 1#4(G) 15 KV WITH IN CABLE TRAY(EACH)
E1 E2 E3 E4 E5 E6
E1-7
E-MV-1
480V SUBSTATION E - LV - 6
(NEWSWITCHBOARD)
SEE DWG. NO. MI-E-110
480V SUBSTATION E - LV - 5
(NEWSWITCHBOARD)
SEE DWG. NO. MI-E-110
480V SUBSTATION E - LV - 1
(EXISTING SWITCHBOARD)
SEE DWG. NO. MI-E-105
480V SUBSTATION E - LV - 2
(EXISTING SWITCHBOARD)
SEE DWG. NO. MI-E-107
SEE DWG. NO. MI-E-109
(EXISTING SWITCHBOARD)
480V SUBSTATION E - LV - 3
1200A, 15KV DISTRIBUTION SWITCHGEAR(NEW) 1200A, 15KV DISTRIBUTION SWITCHGEAR(EXISTING)
480V SUBSTATION E - LV - 4
SEE DWG. NO. MI-E-307
COOLANT OIL TRANSFORE(EXISTING)
ELECTRICAL LEGEND NOTES
1 NO SCALE
ENERGY CENTER OCP TO BE SET AT NOT MORE THAN 600A BY HMMA.
FIELD VIERIFY EXISTING CABLES TO MATCH NEWCABLE TYPE & RATINGS.
IN PARRALLEL WITH EXISTING (1) 3-1C, #2/0 CU CABLE SET.
NEW- 2SETS 3-1C, CU, #2/0, 15 KV, TYPE MV-105 EPR MV CABLES & (1) #4G.
IM-E-103
NO CHANGE
EXIST
ELV4
MODIFIED
EMV1
1- SEE ONE-LINE GENERAL ELECTRICAL NOTES
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
ELV6-NEW ELV5-NEW
NO CHANGE
AFTER MOVE
ELV3-EXIST
NO CHANGE
AFTER MOVE
ELV2-EXIST
NO CHANGE
AFTER MOVE
ELV1-EXIST
1
1
1 1
OCP DEVICE
ONLY- NO
SWITCH
1200 AF
V
E
IR
F
Y
A
T
3
2
0
0
A
F
1
2
0
0
A
T
1
6
0
0
0
A
F
S
P
A
C
E
1
6
0
0
0
A
F
V
E
R
IF
Y
A
T
3
2
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
S
P
A
C
E
1
6
0
0
A
F
8
0
0
A
T
8
0
0
A
F
V
E
R
IF
Y
A
T
2
0
0
0
A
F
V
E
R
IF
Y
A
T
2
0
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
INDICATOR
DETECTOR &
GROUND-FAULT
INDICATOR
DETECTOR &
GROUND-FAULT
INDICATOR
DETECTOR &
GROUND-FAULT
2
3-1/C #1/0 + 1# 4G IN CABLETRAY.
15 KV RATED CABLE SEE SPECS.
PROVIDE NEWMV CABLE FEEDER.
2 2
2
5
0
0
A
T
2
5
0
0
A
F
V
E
R
IF
Y
A
T
2
5
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
S
P
A
C
E
1
6
0
0
A
F
INDICATOR
DETECTOR &
GROUND FAULT
INDICATOR
DETECTOR &
GROUND FAULT
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
1
4000A 4000A
2
5
0
0
A
T
2
5
0
0
A
F
V
E
R
IF
Y
A
T
2
5
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
S
P
A
C
E
1
6
0
0
A
F
(VERIFY)
3.0 A/ 92.4 OHM
NEUT. RESISTOR
(VERIFY)
3.0 A/ 92.4 OHM
NEUT. RESISTOR
(VERIFY)
3.0 A/ 92.4 OHM
NEUT. RESISTOR
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
# #
2
5
0
0
A
T
3
2
0
0
A
F
2
5
0
0
A
T
3
2
0
0
A
F
1-LINE AFTER
SUBSTATION
EMV1
EMV1 SUBSTATION 1-LINE AFTER
3 IN CONDUIT FOR PROTECTION
NEWCONTROL CABLING PER MANUFACTURER
3 3
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
480V SUBSTATION E - LV - 1
ASSEMBLY AREA POWER SUPPLY
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
400
F 100/
100
F 400/
300
DWR-E-6/A
480V3P/3W
PANEL
LOCATION:A/6
MEZAINE LEVEL
ENGINE CONVEYOR.
300
F 30/
20
DWH-400-5
30
ENGINE TOILET AREA
LOCATION:K/7.5
T.R
500 KVA
480 - 480/277V.
3PH, 4W
800N
LPWD-E-7/D
400N
4
0
0
A
, 4
8
0
V
, 3
P
H
, 4
W
B
U
S
D
U
C
T
E
1
-1
A

4
0
0
A
, 4
8
0
V
, 3
P
H
, 4
W
B
U
S
D
U
C
T
E
1
-1
B

4
0
0
A
, 4
8
0
V
, 3
P
H
, 4
W
B
U
S
D
U
C
T
E
1
-1
C

F 60/
60
COMBINATION WELDING RECEP.
LOCATION:COLUMN NO H/8
ENGINE CONVEYOR
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-1
LOCATION:A6/6.4
95
55
F 60/
60
55
WELDING RECEP.
LOCATION:COLUMN NO B/2
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-13
LOCATION:B2/1.2
95
PWD-E-10/C
480V3P/3W
PANEL
SHIPPING AREA
LOCATION:C/10
95
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-12
LOCATION:B8/1.5
95
F 100/
100
STARTER
CONTROL
PANEL
50
95
HVAC/400-11
LOCATION: D3/1.6
DWH-400-1
WOMEN LOCKER
LOCATION:D2/1.7
F 100/
70
70
F
60/
60
WELDING RECEP.
LOCATION:COLUMN NO B/5
PWR-E-5/A
480V3P/3W
PANEL
F
100/
100
LOCATION:A/4.9
DOOR POWER 95
(C
O
L
U
M
N
N
O
B
8
/1
.8
~
8
)
(D
IS
T
A
N
C
E
: 4
0
3
ft) (P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
(C
O
L
U
M
N
N
O
E
~
K
/6
.3
)
(D
IS
T
A
N
C
E
: 3
1
8
ft) (P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
(C
O
L
U
M
N
N
O
E
~
K
/3
.5
)
(D
IS
T
A
N
C
E
: 3
1
7
ft) (P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
F
100/
100
TC95Y
LTG-E-3/2
LOCATION:C/3
T RCP-E-7/C
LOCATION:C/7
F
60/
45 3P,4W120/208V
TRANSFORMER
30 KVA
50N
95N
F
60/
45
LTG-E-7/C
LOCATION:C/7
95N
T RCP-K-10
LOCATION:K1/10
F
100/
40
3P,4W120/208V
TRANSFORMER
15 KVA
40N 30N
4#8-8G
LTG-K-10
LOCATION:K1/10
F
100/
100
95N
LTG-E-6/J
LOCATION:6/J
F
100/
100
95N
LTG-E-6/F
LOCATION:6/F
F
100/
100
95N
LTG-E-3/J
LOCATION:3/J
F
100/
100
95N
LTG-E-3/F
LOCATION:3/F
ENGINE AREA LIHGTING SUPPLY
CABLE TAP BOX CABLE TAP BOX CABLE TAP BOX
800N
55
F 200/
200
PWR-E-7D
480V3P/3W
PANEL
LOCATION:D/7
200
E1-6 E1-5 E1-4 E1-3 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
INDICATOR
(3)
E1-2 E1-1 E1-7
480V SUBSTATION E - LV - 1
ELECTRICAL LEGEND NOTES
400
(C
O
L
U
M
N
N
O
B
8
/1
.8
~
8
)
(P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
(C
O
L
U
M
N
N
O
E
~
K
/6
.3
)
(P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
(C
O
L
U
M
N
N
O
E
~
K
/3
.5
)
(P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
(COLUMN NO A5/5.8~8.6) (DISTANCE : 180ft)
(DISTANCE : 156ft) (COLUMN NO F3/6~9)
(COLUMN NO B2/1.5~4.9) (DISTANCE : 214ft)
(COLUMN NO C3/5.2~8) (DISTANCE : 186ft)
(DISTANCE : 178ft) (COLUMN NO C3/2.1~4.9)
(COLUMN NO D1/2.1~4.5) (DISTANCE : 157ft)
1 NO SCALE
IM-E-104
ELV1 DISTRIBUTION DIAGRAM BEFORE
& ENIGNE LTG
ASSEMBLY AREA
BEFORE ALTERATIONS
DISTRIBUTION DIAGRAM
ELV1 SUSBSTATION
1- SEE ONE-LINE GENERAL ELECTRICAL NOTES
1
V
E
R
IF
Y
A
T
2
0
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
8
0
0
A
T
8
0
0
A
F
V
E
R
IF
Y
A
T
2
0
0
0
A
F
3 4
1
2
0
0
A
T
1
6
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
5 5
INDICATOR
DETECTOR &
GROUND-FAULT
BEFORE
ELV1-EXIST
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
2
CHANGED AND NOWA 3200 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
3
CHANGED AND NOWA 2000 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
4
5
6
CHANGED AND NOWA 800 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
CHANGED AND NOWA 800 AMP FRAME.
THE ORIGINAL 1600 AMP FRAME OCP HAS BEEN
ADDITIONAL 800AF OCP DEVICE WAS ADDED.
THE ORIGINAL GEAR HAS BEEN CHANGED, AND
# #
UNIT
CAPACITOR
45 VAR
4
0
0
A
/ 4
8
0
Y
/ 2
7
7
V
/ 3
P
/ 4
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-1
A
4
0
0
A
/ 4
8
0
Y
/ 2
7
7
V
/ 3
P
/ 4
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-1
B
4
0
0
A
/ 4
8
0
Y
/ 2
7
7
V
/ 3
P
/ 4
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-1
C
2
0
0
0
A
/ 4
8
0
Y
/ 3
P
/ 3
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-3
2000A/ 480Y/ 3P/ 3W/ G
BUS DUCT/PI E1-3
SERVES- POWER SUPPLY TO HEAD-SUB
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3F
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3E
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3D
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3C
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3B
2
0
0
0
A
/ 4
8
0
Y
/ 3
P
/ 3
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-3
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3A
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
480V SUBSTATION E - LV - 1
ASSEMBLY AREA POWER SUPPLY
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
400
F 100/
100
F 400/
300
DWR-E-6/A
480V3P/3W
PANEL
LOCATION:A/6
MEZAINE LEVEL
ENGINE CONVEYOR.
300
T.R
400N
F 60/
60
COMBINATION WELDING RECEP.
LOCATION:COLUMN NO H/8
ENGINE CONVEYOR
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-1
LOCATION:A/7.3
95
55
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-11
LOCATION:A/1.6
95
PWR-E-10/C
480V3P/3W
PANEL
SHIPPING AREA
LOCATION:C/10
95
F 100/
100
VDF
50
HVAC/400-18
LOCATION:A/1.2
95
F
60/
60
WELDING RECEP.
LOCATION:COLUMN NO B/5
PWR-E-5/A
480V3P/3W
PANEL
F
100/
100
LOCATION:A/4.9
DOOR POWER 95
(C
O
L
U
M
N
N
O
B
8
/1
.8
~
8
)
(P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
(C
O
L
U
M
N
N
O
E
~
K
/6
.3
)
(P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
(C
O
L
U
M
N
N
O
E
~
K
/3
.5
)
(P
O
W
E
R
S
U
P
P
L
Y
"L
T
G
P
A
N
E
L
)
F
100/
100
TC95Y
LTG-E-3/2
LOCATION:C/3
T RCP-E-7/C
LOCATION:C/7
F
60/
45 3P,4W120/208V
TRANSFORMER
30 KVA
50N
95N
F
60/
45
LTG-E-7/C
LOCATION:C/7
95N
T RCP-E-K/9
LOCATION:9/K
3P 477- 120/208V
TRANSFORMER
15 KVA
30N
4#8-8G
LP-E-K/9
LOCATION:9/K
F
100/
100
95N
LTG-E-6/J
LOCATION:6/J
F
100/
100
95N
LTG-E-6/F
LOCATION:6/F
F
100/
100
95N
LTG-E-3/J
LOCATION:3/J
F
100/
100
95N
LTG-E-3/F
LOCATION:3/F
ENGINE AREA LIHGTING SUPPLY
CABLE TAP BOX CABLE TAP BOX CABLE TAP BOX
800N 55
F
100/
100
TC95Y
LP-E-1/A
LOCATION:A/1
F
100/
100
95N
PWD-E-K/9
LOCATION:9/K
T RCP-E-1/A
LOCATION:A/1
3P 480- 120/208V
TRANSFORMER
15 KVA
4#8-8G
LTG-K-10
LOCATION:K1/10
PWR-E-K/9
LOCATION:9/K
F
100/
100
TC95Y
LP-E-4/K
LOCATION:K/4
T RCP-E-4/K
LOCATION:K/4
3P 480- 120/208V
TRANSFORMER
15 KVA
4#8-8G
ADD NEW
ADD NEW
TEARDOWN
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-12
LOCATION:A/2.6
95
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-13
LOCATION:A/2.2
95
RE-USE EXISTING
RELOCATED
RE-USE EXISTING
RELOCATED
RE-USE EXISTING
RELOCATED
SF-30HP
RF-10HP
RE-USE EXISTING
RELOCATED
RELOCATED
ELECTRICAL LEGEND NOTES
E1-6 E1-5 E1-4 E1-3
1
2
0
0
A
T
3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
(3)
E1-2 E1-1 E1-7
(COLUMN NO F3/6~9)
(COLUMN NO B2/1.5~4.9)
(COLUMN NO C3/5.2~8)
(COLUMN NO C3/2.1~4.9)
(COLUMN NO D1/2.1~4.5)
1 NO SCALE
IM-E-105
ELV1 DISTRIBUTION DIAGRAM AFTER
& ENIGNE LTG
ASSEMBLY AREA
AFTER ALTERATIONS
& E1-3 BUSDUCT
ELV1 SUSBSTATION
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
# #
SEE ONE-LINE GENERAL ELECTRICAL NOTES
NO CHANGE
AFTER MOVE
ELV1-EXIST
1
8
0
0
A
T
8
0
0
A
F
V
E
R
IF
Y
A
T
2
0
0
0
A
F
V
E
R
IF
Y
A
T
2
0
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
V
E
R
IF
Y
A
T
8
0
0
A
F
INDICATOR
DETECTOR &
GROUND-FAULT
(VERIFY)
3.0 A/ 92.4 OHM
NEUT. RESISTOR
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
UNIT
CAPACITOR
45 VAR
8
0
0
D
1
2
0
0
D
RELOCATED
PWR/E/D07
PANEL
DELETED
DWH-400-5
3P/4W/G
480Y/277V
480D- 3P
500KVA
4
0
0
A
/ 4
8
0
Y
/ 2
7
7
V
/ 3
P
/ 4
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-1
A
4
0
0
A
/ 4
8
0
Y
/ 2
7
7
V
/ 3
P
/ 4
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-1
B
4
0
0
A
/ 4
8
0
Y
/ 2
7
7
V
/ 3
P
/ 4
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-1
C
E/D07
LPWD/
PANEL
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3B
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3C
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3D
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3E
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3F
SERVES- POWER SUPPLY TO HEAD-SUB
REMOVED
RECEPTACLE
WELDING
11
400
HVAC
1
400
DWH
2
0
0
0
A
/ 4
8
0
Y
/ 3
P
/ 3
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-3
2
0
0
0
A
/ 4
8
0
Y
/ 3
P
/ 3
W
/ G
B
U
S
D
U
C
T
/P
I E
1
-3
2000A/ 480Y/ 3P/ 3W/ G
BUS DUCT/PI E1-3
TO NEWLOCATION
REROUTED
BUSWAY
2000 AMP FDR
REMOVED
400A/ 480D/ 3P/ 3W/ G
BUS DUCT/PI E1-3A
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING ITEMS THAT
CLOUDED ITEMS INDICATE
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
480V SUBSTATION E - LV - 2
450KVAR
1200
SPARE SPARE
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
400
F 100/
100
STARTER
CONTROL
PANEL
50 HVAC/400-6
LOCATION:WARE HOUSE
95
F 60/
60
55
COMBINATION WELDING RECEP.
LOCATION:COLUMN NO H/8
ENGINE CONVEYOR
F 60/
LOCATION:COLUMN NO E/8
WELDING RECEP.
60
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-2
LOCATION:E/9.3
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-3
LOCATION:F2/9.3
F 100/
100
STARTER
CONTROL
PANEL
50
LOCATION:G3/9.1
HVAC REMOVE ROOF
HVAC(EXISTING)OUTSIDE
400/
400
F 600/
600
3P 350KVA
ISOLATION TR
TEST CELL
FURNISHED
PANEL
F 600/
600
4" CONDUIT
ENGINE TEST RM.
LOCATION:K8/7
55 95 95 95 600
TC500D
F 100/
100
STARTER
CONTROL
PANEL
50
95
HVAC/400-5
LOCATION:K6/7.2
F 30/
20
DWH-400-5
30
ENGINE TOILET AREA
LOCATION:K/7.5
F 100/
100
PWR-E-10/K
480V3P/3W
PANEL
EXTEND
95
SHIPPING
LOCATION:J9/10
F 60/
40
F
40
HVAC/400-19
LOCATION:K8/7.5
VDF MOUNT VFD FOR
RETURN FAN
SF-15HP
RF- 5HP
STARTER
CONTROL
PANEL
50
95
HVAC/400-4
LOCATION:K6/8.2
F
100/
100
F
100/
70
70
44.3KW
ACCU/400-2
LOCATION:K3/7.7
F
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-1
LOCATION:E/9.3
95
PWD-E-6/L
LOCATION:K8/6
MEZAINE LEVEL
ENGINE TEST RM.
400
LAB AREA
POWER PANEL
480-120/208V 3P,4W
T-5 30KVA
CRCP-E-6/L
PANEL
LTG-E-6/L
PANEL
480-120/208V 3P,4W
T-4 112.5KVA
RCPWD-E-6/L
PANEL
PWR-E-6/L
PANEL
5
4
1 2
3
1 3/4"C-3#8 & 1#10(G)
2 1 1/2"C-5#2 & 1#8(G)
3 1 1/2"C-4#2 & 1#6(G)
4 2"C-4#3/0 & 1#6(G)
5 1 1/2"C-3#2/0 & 1#6(G)
6 3 1/2"C-4#500KCMIL & 1#1/0(G)
6
ELECTRICAL LEGEND NOTES
BLOCK AREA POWER SUPPLY
E2-4 E2-3 E2-2 E2-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
(COLUMN NO G8/6~9)
(DISTANCE : 156ft)
(DISTANCE : 156ft)
(COLUMN NO H8/6~9)
(COLUMN NO J/6~9)
(DISTANCE : 156ft)
(COLUMN NO 6/E~K)
(DISTANCE : 300ft)
(COLUMN NO E8/6~9)
(DISTANCE : 156ft)
(COLUMN NO F3/6~9)
(DISTANCE : 156ft)
(DISTANCE : 156ft)
(COLUMN NO G3/6~9)
1 NO SCALE
IM-E-106
BLOCK LINE
BEFORE ALTERATIONS
& E2-1 BUSDUCT
ELV2 SUSBSTATION
SEE ONE-LINE GENERAL ELECTRICAL NOTES
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
2
CHANGED AND NOWA 3200 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
3
CHANGED AND NOWA 2000 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
4
5
6
CHANGED AND NOWA 800 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
CHANGED AND NOWA 800 AMP FRAME.
THE ORIGINAL 1600 AMP FRAME OCP HAS BEEN
ADDITIONAL 800AF OCP DEVICE WAS ADDED.
THE ORIGINAL GEAR HAS BEEN CHANGED, AND
# #
ELV2 DISTRIBUTION DIAGRAM BEFORE
1
INDICATOR
DETECTOR &
GROUND-FAULT
BEFORE
ELV2-EXIST
2
5
0
0
A
T
3
2
0
0
A
F
V
E
R
IF
Y
A
T
3
2
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
S
P
A
C
E
1
6
0
0
A
F
2 2
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ B
E
2
-1
P
L
U
G
-IN
B
U
S
W
A
Y
2500A/ 480V/ 3P/ 3W/ B
E2-1 PLUG-IN BUSWAY
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ B
E
2
-1
P
L
U
G
-IN
B
U
S
W
A
Y
400A/ 480V/ 3P/ 3W/ G
E2-1A PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1B PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1C PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1D PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1E PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1F PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1G PLUG-IN BUSWAY
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
480V SUBSTATION E - LV - 2
HEAD-SUB/HEAD AREA POWER SUPPLY
SPARE SPARE
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
400
F 60/
60
55
COMBINATION WELDING RECEP.
LOCATION:COLUMN NO H/8
ENGINE CONVEYOR
F 60/
LOCATION:COLUMN NO E/8
WELDING RECEP.
60
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-3
LOCATION:FX/8.8
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-22
LOCATION:G/8.8
F 60/
40
STARTER
CONTROL
PANEL
25
LOCATION:H/9.4
HVAC REMOVE ROOF
HVAC(EXISTING)OUTSIDE
400/
400
PWR-E-6/L
LOCATION:K5.8
SUB-MATERIAL RM.
F 600/
600
3P 350KVA
ISOLATION TR
TEST CELL
FURNISHED
PANEL
F 600/
600
4" CONDUIT
ENGINE TEST RM.
LOCATION:K8/7
55 95 95 40 600
TC500D
F 30/
20
DWH-400-5
30
ENGINE TOILET AREA
LOCATION:K/7.5
F 100/
100
PWR-E-10/K
480V3P/3W
PANEL
EXTEND
95
SHIPPING
LOCATION:J9/10
F 60/
40
F
40
HVAC/400-19
LOCATION:K/7.6
VDF MOUNT VFD FOR
RETURN FAN
SF-15HP
RF- 5HP
STARTER
CONTROL
PANEL
50
95
HVAC/400-4
LOCATION:K/8.2
F
100/
100
F
100/
90
85
57KW
ACCU/400-3
LOCATION:K/7.2
F
LAB AREA
POWER PANEL
CRCP-E-6/L
PANEL
LTG-E-6/L
PANEL
480-120/208V 3P,4W
T-4 112.5KVA
RCPWD-E-6/L
PANEL
RCP-ED-E-6/L
PANEL
4
3
1
2
1
2
1 1/2"C-5#2 & 1#8(G)
3
1 1/2"C-4#2 & 1#6(G)
4
5
1 1/2"C-3#2/0 & 1#6(G)
3 1/2"C-4#500KCMIL & 1#1/0(G)
5
2"C-4#3/0 & 1#6(G)
F 100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-2
LOCATION:E/8.8
95
F
60/
40
STARTER
CONTROL
PANEL
25
HVAC/400-21
LOCATION:D/8
40
HVAC/400-6
F 60/
40
F
40
HVAC/400-20
LOCATION:K/10
VDF
MOUNT VFD FOR
RETURN FAN
SF-15HP
RF- 7.5HP
F
100/
100
STARTER
CONTROL
PANEL
50
HVAC/400-5
LOCATION:K/7.2
95
RELOCATED
RELOCATED
RE-USE EXISTING
RELOCATED
RE-USE EXISTING RELOCATED
RE-USE EXISTING
RELOCATED
RE-USE EXISTING
NEW NEW
ELECTRICAL LEGEND NOTES
E2-4 E2-3 E2-2 E2-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
(COLUMN NO E8/6~9)
(DISTANCE : 156ft)
(COLUMN NO F3/6~9)
(DISTANCE : 156ft)
(COLUMN NO G3/6~9)
(DISTANCE : 156ft)
(COLUMN NO G8/6~9)
(DISTANCE : 156ft)
(COLUMN NO H8/6~9)
(DISTANCE : 156ft)
(COLUMN NO J/6~9)
(DISTANCE : 156ft)
(COLUMN NO 6/E~K)
(DISTANCE : 300ft)
1 NO SCALE
IM-E-107
(H/S-H)
AFTER ALTERATIONS
& E2-1 BUSDUCT
ELV2 SUSBSTATION
ELV2 DISTRIBUTION DIAGRAM AFTER
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
# #
SEE ONE-LINE GENERAL ELECTRICAL NOTES
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING ITEMS THAT
CLOUDED ITEMS INDICATE
NO CHANGE
AFTER MOVE
ELV2-EXIST
1
V
E
R
IF
Y
A
T
3
2
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
S
P
A
C
E
1
6
0
0
A
F
INDICATOR
DETECTOR &
GROUND-FAULT
(VERIFY)
3.0 A/ 92.4 OHM
NEUT. RESISTOR
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
2
5
0
0
A
T
3
2
0
0
A
F
1
2
0
0
Y
NEWELV2 LOCATION
REROUTE BUSWAY TO
UNIT
CAPACITOR
450 KVAR
400A/ 480V/ 3P/ 3W/ G
E2-1A PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1B PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1C PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1D PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1E PLUG-IN BUSWAY
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ B
E
2
-1
P
L
U
G
-IN
B
U
S
W
A
Y
400A/ 480V/ 3P/ 3W/ G
E2-1F PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E2-1G PLUG-IN BUSWAY
2500A/ 480V/ 3P/ 3W/ B
E2-1 PLUG-IN BUSWAY
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ B
E
2
-1
P
L
U
G
-IN
B
U
S
W
A
Y
400D
RELOCATED TO NEWAREA
EXISTING LAB AREA
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
480V SUBSTATION E - LV - 3
HEAD AREA POWER SUPPLY(IN CRANK)
450KVAR SPARE SPARE
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
TC400D
F 60/
60
55
WELDING RECEP.
LOCATION:COLUMN NO H/2
F 100/
90
STARTER
CONTROL
PANEL
57KW
HVAC/400-3
LOCATION:D8/7.4
F 200
150
95.6KW
ACCU/400-1
LOCATION:G1/1.9
F
600/
600
90 150
F 100/
100
STARTER
CONTROL
PANEL
50
95
HVAC/400-7
LOCATION:K5/4.2
F
400/400
F
400/400
F 60/
45
F
50
HVAC/400-20
LOCATION:D8/7.4
VDF MOUNT VFD FOR
RETURN FAN
SF-15HP
RF- 7.5HP
ROOF ROOF MEZZANINE
PWD-E-1/H
OFFICE AREA
POWER PANEL
480-120/208V 3P,4W
T-2 75KVA
RCP2-E-1/H
PANEL
RCP1-E-1/H
PANEL
LTG-E-1/H
PANEL
480-120/208V 3P,4W
T-1 45KVA
CRCP-E-1/H
PANEL
PWR1-E-1/H
PANEL
PWR2-E-1/H
PANEL
600
7
6
5
1 2
3
4
1 1 1/4" C-3#1 & 1#6(G)
2 2"C-4#3/0 & 1#6(G)
3 2"C-4#3/0 & 1#6(G)
4 1 1/2"C-4#2 & 1#6(G)
5 1 1/2"C-4#2 & 1#6(G)
6 2"C-4#3/0 & 1#6(G)
7 1"C-3#4 & 1#8(G)
8 2"C-5#1/0 & 1#6(G)
8
F 100/
100
STARTER
CONTROL
PANEL
50
95
HVAC/400-8
LOCATION:K5/2.8
F 60/
60
55
F 30/
20
20
CP DO
DOOR POWER
LOCATION:COLUMN NO D9/1
WELDING RECEP.
LOCATION:COLUMN NO E/2
F 30/
20
CUH/400-1
LOCATION:E2/1
20
F
100
STARTER
CONTROL
PANEL
50 HVAC/400-10
LOCATION:F2/1.6
95
F 100/
70
F
70
HVAC/400-18
LOCATION:F8/1.8
VDF MOUNT VFD FOR
RETURN FAN
SF-30HP
RF- 10HP
(DISTANCE : 160ft) 100
STARTER
CONTROL
PANEL
50 HVAC/400-9
LOCATION:WARE HOUSE
95
100/
F 30/
20
20
DWH-400-1
TOILET
LOCATION:COLUMN NO J2/1.8
PWR-E-1/K
PANEL
F 100/
100
95
LOCATION:COLUMN NO J8/1
F 60/
60
55
WELDING RECEP.
LOCATION:COLUMN NO H/5
F 60/
60
55
WELDING RECEP.
LOCATION:COLUMN NO E/5
(COLUMN NO G4/1.8)
(EPS ROOM)
ELECTRICAL LEGEND NOTES
1200
E3-4 E3-3 E3-2 E3-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
(COLUMN NO D.9~3~8.5/E~J6)
(DISTANCE : 696ft)
(DISTANCE : 160ft)
(COLUMN NO G8/2.1~4.6)
(COLUMN NO G2/2.1~4.6)
(DISTANCE : 160ft)
(DISTANCE : 160ft)
(COLUMN NO F6/2.1~4.6)
(COLUMN NO H5/2.1~4.6)
(COLUMN NO J3/2.1~4.6)
(DISTANCE : 160ft)
(CRANK LINE AREA)
(COLUMN NO 5.2/E~J.3)
(DISTANCE : 275ft)
(COLUMN NO 5.4/E~J.8)
(DISTANCE : 300ft)
(CRANK LINE AREA)
(COLUMN NO E2/2.1~4.6)
(DISTANCE : 160ft)
(COLUMN NO E8/2.1~4.6)
(DISTANCE : 160ft)
1 NO SCALE
IM-E-108
AREA
HEAD & CRANK
BEFORE ALTERATIONS
& E3-1 BUSDUCT
ELV3 SUSBSTATION
SEE ONE-LINE GENERAL ELECTRICAL NOTES
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
2
CHANGED AND NOWA 3200 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
3
CHANGED AND NOWA 2000 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
4
5
6
CHANGED AND NOWA 800 AMP FRAME.
THE ORIGINAL 2500 AMP FRAME OCP HAS BEEN
CHANGED AND NOWA 800 AMP FRAME.
THE ORIGINAL 1600 AMP FRAME OCP HAS BEEN
ADDITIONAL 800AF OCP DEVICE WAS ADDED.
THE ORIGINAL GEAR HAS BEEN CHANGED, AND
# #
ELV3 DISTRIBUTION DIAGRAM BEFORE
1
INDICATOR
DETECTOR &
GROUND-FAULT
BEFORE
ELV3-EXIST
2
5
0
0
A
T
3
2
0
0
A
F
V
E
IR
F
Y
A
T
3
2
0
0
A
F
1
2
0
0
A
T
1
6
0
0
0
A
F
S
P
A
C
E
1
6
0
0
0
A
F
2 2
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
2500A/ 480V/ 3P/ 3W/ G
E3-1 PLUG-IN BUSWAY
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ G
E
3
-1
F
E
E
D
E
R
B
U
S
W
A
Y
400A/ 480V/ 3P/ 3W/ G
E3-1A PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1B PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1C PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1D PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1E PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1F PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1G PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1H PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1J PLUG-IN BUSWAY
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ G
E
3
-1
P
L
U
G
-IN
B
U
S
W
A
Y
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
480V SUBSTATION E - LV - 3
BLOCK AREA POWER SUPPLY(IN CRANK)
450KVAR
SPARE SPARE
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
F
400/400
TC400D
F 60/
60
55
WELDING RECEP.
LOCATION:COLUMN NO H/2
F 200
150
95.6KW
ACCU/400-4
LOCATION:B1/1.2
150
F 100/
100
STARTER
CONTROL
PANEL
50
95
HVAC/400-7
LOCATION:K5/4.2
F
400/400
F
400/400
ROOF
F 100/
100
STARTER
CONTROL
PANEL
50
95
HVAC/400-8
LOCATION:K5/2.8
F 60/
60
55
F 30/
20
20
CP DO
DOOR POWER
LOCATION:COLUMN NO D9/1
WELDING RECEP.
LOCATION:COLUMN NO E/2
F 30/
20
CUH/400-1
LOCATION:E2/1
20
F
100
STARTER
CONTROL
PANEL
50 HVAC/400-10
LOCATION:E8/1.2
95
100
STARTER
CONTROL
PANEL
50 HVAC/400-9
95
100/
F 30/
20
20
DWH-400-4
TOILET
LOCATION:COLUMN NO J2/1.8
F 60/
60
55
WELDING RECEP.
LOCATION:COLUMN NO H/5
F 60/
60
55
WELDING RECEP.
LOCATION:COLUMN NO E/5
TEARDOWN
RELOCATED
RE-USE EXISTING
CAC/400-1
LOCATION:A8/1.8
RELOCATED
RE-USE EXISTING
RELOCATED
RE-USE EXISTING
RE-USE EXISTING
LOCATION:COLUMN NO J/1.2
RELOCATED
RE-USE EXISTING
RELOCATED
RE-USE EXISTING
RELOCATED
ELECTRICAL LEGEND NOTES
(DISTANCE : 696ft)
(COLUMN NO D.9~3~8.5/E~J6)
(COLUMN NO E2/2.1~4.6)
(DISTANCE : 160ft)
(COLUMN NO E8/2.1~4.6)
(DISTANCE : 160ft)
(COLUMN NO F6/2.1~4.6)
(DISTANCE : 160ft)
(COLUMN NO G2/2.1~4.6)
(DISTANCE : 160ft)
(COLUMN NO G8/2.1~4.6)
(DISTANCE : 160ft)
(COLUMN NO H5/2.1~4.6)
(DISTANCE : 160ft)
(COLUMN NO J3/2.1~4.6)
(DISTANCE : 160ft)
(COLUMN NO 5.2/E~J.3)
(DISTANCE : 275ft)
(CRANK LINE AREA)
(COLUMN NO 5.4/E~J.8)
(DISTANCE : 300ft)
(CRANK LINE AREA)
E3-4 E3-3 E3-2 E3-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
1 NO SCALE
IM-E-109
AREA
HEAD & CRANK
AFTER ALTERATIONS
& E3-1 BUSDUCT
ELV3 SUSBSTATION
ELV3 DISTRIBUTION DIAGRAM AFTER
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
# #
SEE ONE-LINE GENERAL ELECTRICAL NOTES
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING ITEMS THAT
CLOUDED ITEMS INDICATE
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ G
E
3
-1
F
E
E
D
E
R
B
U
S
W
A
Y
2500A/ 480V/ 3P/ 3W/ G
E3-1 PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1A PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1B PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1C PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1D PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1E PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1F PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1G PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1H PLUG-IN BUSWAY
400A/ 480V/ 3P/ 3W/ G
E3-1J PLUG-IN BUSWAY
1
2
0
0
Y
ELV3 & RECONNECT
REROUTED TO RELOCATED
E3-1 FEEDER BUSWAY
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ G
E
3
-1
P
L
U
G
-IN
B
U
S
W
A
Y
NO CHANGE
AFTER MOVE
ELV3-EXIST
1
2
5
0
0
A
T
3
2
0
0
A
F
V
E
IR
F
Y
A
T
3
2
0
0
A
F
1
2
0
0
A
T
1
6
0
0
0
A
F
S
P
A
C
E
1
6
0
0
0
A
F
INDICATOR
DETECTOR &
GROUND-FAULT
(VERIFY)
3.0 A/ 92.4 OHM
NEUT. RESISTOR
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
52
51
50/
51N
50/ CM
1200AF
200AT
13800/120V
52
51
50/
51N
50/ CM
52
51
50/
51N
50/ CM
52
51
50/
51N
50/ CM
1200AF
(2)
52
51
50/
51N
50/ CM
1200AF
52
51
50/
51N
50/ CM 51
50/
51N
50/ CM
1200AF
PROVISION
51
50/
51N
50/ CM
BLANK
1200AF
E5-4 E5-3 E5-2 E5-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
E6-4 E6-3 E6-2 E6-1 3500/5A
TRANSFORMER
FANS
480/120V
AS
A
WHD
PF
VS
A
3 CTS
(3)
GF
Y
49T 30
86
1200AF 1200AF
E1 E2 E3 E4 E5 E6 E-MV-1
1200A, 15KV DISTRIBUTION SWITCHGEAR(NEW) 1200A, 15KV DISTRIBUTION SWITCHGEAR(EXISTING)
ELECTRICAL LEGEND NOTES
SPARE SPARE
FROM TO ENGIN FACTORY HEAD
F F
1 NO SCALE
IM-E-110
THETA NU ENGINE
1-LINE DIAGRAM
NEWSUBSTATION
ELV5 & ELV6
1
(TVSS) UNIT TO BE INSTALLED BY OWNER / HMMA
FOR TRANSIENT VOLTAGE SURGE SUPERSSION
PROVIDE CABLE LUGS (#10-#2/0 RANGE CABLE)
2
3-1/C #1/0 + 1# 4G IN CABLETRAY.
15 KV RATED CABLE SEE SPECS.
PROVIDE NEWMV CABLE FEEDER.
# #
SEE ONE-LINE GENERAL ELECTRICAL NOTES
EXCEPT WHERE NOTED
ALL WORK ON THIS SHEET IS NEWWORK
ENERGY CENTER OCP TO BE SET AT NOT MORE THAN 600A BY HMMA.
FIELD VIERIFY EXISTING CABLES TO MATCH NEWCABLE TYPE & RATINGS.
IN PARRALLEL WITH EXISTING (1) 3-1C, #2/0 CU CABLE SET.
NEW- 2SETS 3-1C, CU, #2/0, 15 KV, TYPE MV-105 EPR MV CABLES & (1) #4G.
MODIFIED
EMV1
ELV6-NEW ELV5-NEW
1
OCP DEVICE
ONLY- NO
SWITCH
1200 AF
2 2
2
5
0
0
A
T
2
5
0
0
A
F
V
E
R
IF
Y
A
T
2
5
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
S
P
A
C
E
1
6
0
0
A
F
INDICATOR
DETECTOR &
GROUND FAULT
INDICATOR
DETECTOR &
GROUND FAULT
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
(VERIFY)
3A / 92.4 OHM
NEUT. RESISTOR
1
4000A 4000A
2
5
0
0
A
T
2
5
0
0
A
F
V
E
R
IF
Y
A
T
2
5
0
0
A
F
1
2
0
0
A
T
1
6
0
0
A
F
S
P
A
C
E
1
6
0
0
A
F
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
TRANSFORMER
DRY TYPE VPE
2000/ 2667 KVA
13.8 KV- 480Y/277V
1-LINE THETA NU ENGINE
ELV5 & ELV6 NEW SUBSTATION
480V/ 3P/ 3W/ G 480V/ 3P/ 3W/ G
SPECS
UNIT- SEE
CAPACITOR
450 KVAR
NEW
C
A
B
L
E
T
A
P
B
O
X
N
E
W
2
5
0
0
A
1
2
0
0
Y
2
5
0
0
D
1
2
0
0
Y
SPARE SPARE
SPECS
UNIT- SEE
CAPACITOR
450 KVAR
NEW
1
3
5
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/G
N
E
W
E
6
-1
A
P
L
U
G
-IN
B
U
S
W
A
Y
S
E
E
P
L
A
N
F
O
R
L
A
Y
O
U
T
S
E
R
V
E
S
F
A
C
T
O
R
Y
B
L
O
C
K
1
3
5
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/G
N
E
W
E
6
-1
B
P
L
U
G
-IN
B
U
S
W
A
Y
S
E
E
P
L
A
N
F
O
R
L
A
Y
O
U
T
S
E
R
V
E
S
F
A
C
T
O
R
Y
H
E
A
D
1600D 1600D
1350A FUSE
1600A/ 3P/G
1350A FUSE
1600A/ 3P/G
TAP BOX
1350A/3W/G
TAP BOX
1350A/3W/G
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/G
N
E
W
E
6
-1
F
E
E
D
E
R
B
U
S
W
A
Y
S
E
E
P
L
A
N
S
F
O
R
L
A
Y
O
U
T
2
5
0
0
A
/ 4
8
0
V
/ 3
P
/ 3
W
/ G
N
E
W
E
5
-1
F
E
E
D
E
R
B
U
S
W
A
Y
S
E
E
P
L
A
N
F
O
R
L
A
Y
O
U
T
S
E
R
V
E
S
C
R
A
N
K
L
IN
E
3 INSTALLED IN CONDUIT FOR PROTECTION
CONTROL CABLING PER MANFUACTURER
3 3
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4
-
0
"
64-0"
E D
9
8
ELEC. ROOM
EXISTING
64-0" 64-0"
D
1
ENLARGED EXISTING ELECTRICAL ROOM BEFORE
40 20 01 IN = 08 FT 60
IM-E-111
BEFORE
ELV1
BEFORE
EMV1
BEFORE
ELV2
13.8KV>480Y/277V
2000KVA
13.8KV>480Y/277V
2000KVA
BEFORE
ELV3
15KV MV
1200A@
1- SEE ONE-LINE GENERAL ELECTRICAL NOTES
VERIFY EXACT ARRANGMENT.
LAYOUT BEFORE CHANGES & MOCIFICATION, FIELD
2- THIS DRAWING SHOWTHE EXISTING EQUIPMENT &
UNIT
CAPACITOR
PWR/MES/E
PANEL PWR/E/D07
PANEL
EMERGENCY POWER
480Y/277V/3P/4W
EMS UPS UNIT FOR
FOR EMERGENCY POWER
EMS UPS BATTERY UNIT
PANEL
CELLULAR
UNIT
CAPACITOR
UNIT
CAPACITOR
EMERGENCY LTG PWR
480Y/277V/3P/4W
UPS-LLTG UNIT FOR
EPWD/400
PANEL
EPWD/E/E07
PANEL
480D-480Y/277V
LIGHTING- 500KVA
TRANSFORMER
12 WIDE / ELEV 28
MV CABLE TRAY
ELEV- 26-0"
2500A/ 480V/ 3PH/ 3W/ G
E2-1 FEEDER BUSWAY
ELEV- 26-0"
2500A/ 480V/ 3PH/ 3W/ G
E3-1 FEEDER BUSWAY
ELEV- 27-6"
2500A/ 480V/ 3PH/ 3W/ G
E1-3 FEEDER BUSWAY
BEFORE ALTERATIONS
ELECTRICAL ROOM
NEWSUBSTATION
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
7
6
42-8"
UPS
140
ELEC. RM
141
Ax
A 404
1
3-8 13/16 "
33-3 3/16 "
2
-
0
"
ELECTRICAL LEGEND NOTES
15KV DISTRIBUTION SWITBOARD
EQUIPMENT CONTENT
2000KVA TRANSFORMER(E-TR-1)
(13.8KV / 480V / 277V DRY TYPE)
N O REMARK
1
2
3
4
5
6
7
8
9
10
11
EXISTING
2000KVA TRANSFORMER(E-TR-2)
(13.8KV / 480V / 277V DRY TYPE)
480V / 277V PANEL BOARD
2000KVA TRANSFORMER(E-TR-3)
(13.8KV / 480V / 277V DRY TYPE)
480V / 277V PANEL BOARD
(480V / 277V DRY TYPE)
500KVA TRANSFORMER(ONLY LIGHTING)
CAPACITOR 3P 480V 450KVAR
UPS 3P 480/277V EMERGENCY LTG.
BATTERY PANEL
A
B
C
15KV DISTRIBUTION SWITCHBOARD
2000KVA TRANSFORMER(E-TR-5,6)
(13.8KV / 480V / 277V DRY TYPE)
NEW
480V / 277V PANEL BOARD
NEW
NEW
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
12
13
UPS 3P 120/208V MES SYSTEM
BATTERY PANEL
EXISTING
EXISTING
D CAPACITOR 3P 480V 450KVAR NEW
3P 50KVA
3P 50KVA
EXISTING a PWR-E-7/D 3P 480V (VAV POWER )
EXISTING b PWR-MES-E 3P 4W120/208V(UPS)
EXISTING c
EMLTG-E-7D(EMERGENCY LTG)
EXISTING d EPWD-400 (UPS EMERG. PANEL)
EXISTING e
LPWD-E-7/D (GENERAL LTG PANEL)
3P 4W480V/277V
3P 4W480V/277V
480V SUBSTATION E - LV - 1
480V / 277V PANEL BOARD
3 - 1/C # 2/0 15KV TYPE MV-105
EPR CABLE & 1#G IN CABLE TRAY(EXISTING)
2 - 3 -1/C #2/0 15KV TYPE MV-105
EPR CABLE & 1#GIN CABLE TRAY(NEWADDITION)
FROM:E-HV-1 , TO: E-LV-1,2,3,4,5,6
2@[3-1/2"C-3 # 500kcmil & 1 # 1(G)]
FROM:E-LV-1 , TO: LTG 500KVA T.R
FROM: LTG 500KVA T.R , TO:LPWD-E-7/D
3"C - 3 #500kcmil & 1 # 3(G)
FROM: E-LV-1,2,3,4,5,6 , TO: CAPACITOR(EACH)
2"C - 4 # 3/0 & 1 # 6(G)
FROM: E1-3 BUSDUCT , TO: PWR-E-7/D
1-1/4"C - 3 # 2 & 1 # 6(G)
FROM: EPWD-400 , TO: EMS UPS
2"C - 4 # 3/0 & 1 # 6(G)
FROM: EMERGY BUILDING , TO: EPWD-400
1"C - 4 # 6 & 1 # 10(G)
FROM: EPWD-400 , TO: EMERGENCY LTG UPS
1
2
3
4
5
6
7
8
INSTALLATION, CHECK CONSTRUCTION.
WITH THE REPRESENTATIVE PRIOR TO
ELEC.RM
141
UPS
140
1 A
2
3
4 5 6 7
8
9
9
9
D
10
D
11 12 13
B B C C
a
b c
d
e
SLOPE
DOWN
12" WIDE 15KV CABLE TRAY
ELEV. 23-5" BOT
1 2
1 2
2
x3
2
x2
2
x2
2
x1
2
x1
2000 AMPS 480V, 3PH, 3W
BUS DUCT "E1-3"
EL. 24
E1
E2
E4
E3
E5
E6
E-
MV1
PRO
BLA
UP
E-LV-1
E-LV-2 E-LV-3
E-LV-5 E-LV-6
ELEV. 23-5" BOT
CAPACITOR 3P 480V 450KVAR
3
4
3
3
3
4
4
4
ALL CONDUIT LINE
4
4
x2
F
8 6
7
2000A/ 480V/ 3P/ 3W/ G
E1-3 BUSWAY @27-6" AFF
12" WIDE @23-5" AFF
CABLE TRAY- 15KV CABLE
12" WIDE @30-0" AFF
CABLE TRAY- 15KV CABLE
25-0" TO 28-0"
VERT. BUS RISE
25-0" TO 28-0"
VERT. BUS RISE
25-0" TO 28-0"
VERT. BUS RISE
25-0" TO 29-0"
VERT. BUS RISE
400A/ 480Y/ 277V/ 3P/ 4W/ G
E1-1A,1B,1C (3) BUSWAYS @29 AFF
2500A/ 480V/ 3P/ 3W/ G
E5-1 BUSWAY @29 AFF
25-0" TO 29-0"
VERT. BUS RISE
25-0" TO 29-0"
VERT. BUS RISE
PULL BOX(24"x24"x24")
3-1/C #1/0 & 1#4(G) 15 KV WITH IN CABLE TRAY(EA)
FROM ENERGY CENTER TO THETA NU SUBSTATION
1
40 20 01 IN = 08 FT 60
IM-E-112
ENLARGED NEW SUBSTATION ELECTRICAL ROOM AFTER
1- SEE ONE-LINE GENERAL ELECTRICAL NOTES
MODIFICATIONS.
RELOCATED AND NEWEQUIPMENT & LAYOUT AND
2- THIS DRAWING SHOWTHE NEWLOCATION WITH THE
2500A/ 480V/ 3P/ 3W/ G
E6-1 BUSWAY @29 AFF
2500A/ 480V/ 3P/ 3W/ G
E2-1 BUSWAY @28 AFF
2500A/ 480V/ 3P/ 3W/ G
E3-1 BUSWAY @28 AFF
CRITERIA.
3- SEE ELECTRICAL SPECIFICATIONS FOR EQUIPMENT
AFTER ALTERATIONS
ELECTRICAL ROOM
NEWSUBSTATION
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
7
6
42-8"
UPS
140
ELEC. RM
141
Ax
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
7
6
42-8"
UPS
140
ELEC. RM
141
Ax
404
1
N O EQUIPMENT CONTENT REMARK
1
2
3
4
5
6
7
8
9
10
11
15KV DISTRIBUTION SWITBOARD
2000KVA TRANSFORMER(E-TR-1)
(13.8KV / 480V / 277V DRY TYPE)
EXISTING
480V / 277V PANEL BOARD
2000KVA TRANSFORMER(E-TR-2)
(13.8KV / 480V / 277V DRY TYPE)
480V / 277V PANEL BOARD
2000KVA TRANSFORMER(E-TR-3)
(13.8KV / 480V / 277V DRY TYPE)
480V / 277V PANEL BOARD
(480V / 277V DRY TYPE)
500KVA TRANSFORMER(ONLY LIGHTING)
CAPACITOR 3P 480V 450KVAR
UPS 3P 480/277V EMERGENCY LTG.
BATTERY PANEL
A
B
C
15KV DISTRIBUTION SWITCHBOARD
2000KVA TRANSFORMER(E-TR-5,6)
(13.8KV / 480V / 277V DRY TYPE)
NEW
480V / 277V PANEL BOARD
NEW
NEW
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
12
13
UPS 3P 120/208V MES SYSTEM
BATTERY PANEL
EXISTING
EXISTING
ELEC.RM
141
UPS
140
5-10 5/8 "
7
-
6
"
9
-
0
"
9
-
0
"
9
-
0
"
1
1
-
4

1
/
2

"
9-10 1/2 "
6-5"
7-11"
9
-
0
"
7
-
6
"
6
-
0
"
3
-
3

1
5
/
1
6

"
5
-
6
"
3
-
0
"
3
-
2
"
2
-
1
0
"
9
-
0
"
5
-
6
"
9
-
0
"
8
-
0
"
1
1
-
4

1
/
2

"
3-0"
15-0" 9-10 1/2 " 5-6"
5-7"
7-11"
2-4"
2
-
1
1

7
/
1
6

"
9
-
0
"
7
-
5

1
/
1
6

"
9
-
0
"
7
-
0
"
1
4
-
1
1
"
3
-
2
"
5
-
6
"
1
-
6
"
9
-
0
"
1 1 1 A A
2
3
3
3
3
4 5 5 5 6 7 7 7
8
9
9
9
D
10
D CAPACITOR 3P 480V 450KVAR NEW
D
11
3P 50KVA
3P 50KVA
12 13
B B C C C C C C
2-0" 2-9"
3-4"
2-9"
3-4"
2-0"
15-0 5/8 "
2-4"
3
-
1

1
1
/
1
6

"
ELEC.RM
141
UPS
140
TYP - FIELD VERIFY EXISTING
GROUND CABLE, CONDUIT & SIZE
TYP - BOND NEWTO EXISTING
VIA EXOTHERMIC CAD-WELD
TYP - #4/0 BARE CU TO
10 FT GROUND ROD
TYP - #4/0 BARE CU TO
10 FT GROUND ROD
TYP - #4/0 BARE COPPER GROUND
CONDUCTOR. EXOTHERMIC CAD-WELD
ALL CONNECTIONS.
TYP - FIELD VERIFY EXISTING
GROUND CABLE, CONDUIT & SIZE
15KV DISTRIBUTION SWITCHBOARD
13.8KV / 480V / 277V
E-LV-1
DRY TYPE 2000KVA E-TR-1
13.8KV / 480V / 277V
DRY TYPE 2000KVA E-TR-2
13.8KV / 480V / 277V
DRY TYPE 2000KVA E-TR-3
13.8KV / 480V / 277V
DRY TYPE 2000KVA E-TR-5
13.8KV / 480V / 277V
DRY TYPE 2000KVA E-TR-6
E-LV-2 E-LV-3
E-LV-5 E-LV-6
#4/0 COPPER GROUND IN 1"
CONDUIT- RUN OVERHED BETWEEN
GROUND BUS AND EQUIPMENT.
(TYP")
1/4" X 2" GROUND BUS (TYP)
5
-
0

3
/
1
6

"
8
-
2
"
E-MV-1
E1
E2 E3
E4
E6
E5
BLANK
PROVISION
EXISTING a PWR-E-7/D 3P 480V (VAV POWER )
EXISTING b PWR-MES-E 3P 4W120/208V(UPS)
EXISTING c
EMLTG-E-7D(EMERGENCY LTG)
EXISTING d EPWD-400 (UPS EMERG. PANEL)
EXISTING e
LPWD-E-7E (GENERAL LTG PANEL)
3P 4W480V/277V
3P 4W480V/277V
a b c d
e
2-0"
3-11 15/16 " 2-8" 3-7 7/16 "
1-8"
3
-
2
"
8
-
3
"
4-1"
6-3 1/4 "
1
40 20 01 IN = 08 FT 60
IM-E-113
ENLARGED NEW SUBSTATION ELECT. EQUIP. PLACEMENT
1
40 20 01 IN = 08 FT 60
ENLARGED NEW SUBSTATION ELECT. RM. GROUNDING
1- SEE ONE-LINE GENERAL ELECTRICAL NOTES
MODIFICATIONS.
RELOCATED AND NEWEQUIPMENT & LAYOUT AND
2- THIS DRAWING SHOWTHE NEWLOCATION WITH THE
CRITERIA.
3- SEE ELECTRICAL SPECIFICATIONS FOR EQUIPMENT
GROUNDING
PLACMENT &
ELECTRICAL ROOM
NEWSUBSTATION
ENLARGED NEW
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
SAG RODS, REFER TO STR. DWG.
ELEC.RM
141
ELEC.RM
141
T.O.CMU KNEE WALL
ELEV.= 4-0"
T.O.CONC. SLAB
ELEV. = 0-0"
DOWN SPOUT
-SEE MECH.DWG
ARCH D - SCALE: 1/4" = 1-0"
ENLARGED SUBSTATION SECTION 1
E
T.O.CONC. SLAB
ELEV. = 0-0"
B.O. STEEL
ELEV.= 22-4"
at LINE6,7
ELEV.= 31-4"~32-4" 42-8"
ARCH D - SCALE: 1/4" = 1-0"
ENLARGED SUBSTATION SECTION 2
E
EXISTING T.O.TRUSS
T.O.CMU KNEE WALL
ELEV.= 4-0"
64-0" 2-4"
6
CONC. GRADE BEAM,
REFER TO STR. DWG.
PRE-FIN. INSULATED
EXTERIOR MTL. WALL
PANEL
WEEP HOLES @32" O.C.
CONC. GRADE BEAM,
REFER TO STR. DWG.
CONC. SLAB,
REFER TO STR.
DWG.
BASE FLASH
8x16x4" CONCRETE MASONRY
UNIT
8x16x4" CLAY BLOCK UNIT
MORTAR FILL
A Ax
PRE-FIN. INSULATED
EXTERIOR MTL. WALL
PANEL
SEE STR. DWG
7
CONC. SLAB,
REFER TO STR.
DWG.
SEE STR. DWG
B.O. STEEL
ELEV.= 23-0"
B.O. E1-3
ELEV.= 27-6"
B.O. E1-3
ELEV.= 24-0"
ELEV.= 23-5"
B.O. TRAY
OPEN
ELEV.= 23-5"
B.O. TRAY
B.O. E1-3
ELEV.= 24-0"
M/V CONDUIT LINE
B.O. E2-1
ELEV.= 28
B.O. E3-1
ELEV.= 28
B.O. E3-1
ELEV.= 25
B.O. E2-1
ELEV.= 25
B.O. E1-1A,1B,1C
ELEV.= 29
P.B
OPEN
B.O. E1-3
ELEV.= 24-0"
OPEN OPEN
B.O. E3-1
ELEV.= 25
B.O. E2-1
ELEV.= 25
B.O. E6-1
ELEV.= 25
B.O. E5-1
ELEV.= 25
1
ENLARGED NEW SUBSTATION ELECT. RM. SECTION-A
30 20 10 01 IN = 04 FT
1
ENLARGED NEW SUBSTATION ELECT. RM. SECTION-B
30 20 10 01 IN = 04 FT
IM-E-114
SECTIONS
ELECTRICAL ROOM
NEWSUBSTATION
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
DISTRIBUTION SWITCHE BOARD DISTRIBUTION SWITCHE BOARD DISTRIBUTION SWITCHE BOARD
DISTRIBUTION SWITCHE BOARD DISTRIBUTION SWITCHE BOARD DISTRIBUTION SWITCHE BOARD
IM-E-115
01
SCHEDULES
DISTRIBUTION
ELECTRICAL
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
PANEL SCHEDULE PANEL SCHEDULE PANEL SCHEDULE
PANEL SCHEDULE PANEL SCHEDULE LIGHTING T.R SCHEDULE
IM-E-116
02
SCHEDULES
DISTRIBUTION
ELECTRICAL
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
PANEL SCHEDULE PANEL SCHEDULE PANEL SCHEDULE
PANEL SCHEDULE PANEL SCHEDULE PANEL SCHEDULE
IM-E-117
03
SCHEDULES
DISTRIBUTION
ELECTRICAL
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
BLOCK
CRANK
HEAD HEAD-SUB
ASSEMBLY
COOLANT
6
4
-
0
"
48-0" 64-0" 64-0 1/16" 64-0" 64-0" 62-0" 64-0" 64-0" 64-0" 64-0"
ELEC. ROOM
MEASURING RM
CALIBRATION RM
MATERIAL AREA
CELL3
CELL2
CELL1
OFFICE
CONF. RM
SUB-MATERIAL RM
BREAK RM OPEN OFFICE
2-0"
624-0"
5
7
6
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
SHIPPING/ RECEIVING
10
A B D E F G H J K L C
9
8
7
6
5
4
3
2
1
Fx
SHIPPING/ RECEIVING
PURITY PARTS
STORAGE
ENGINE TEST
TOOL RM
ES TEST RM
SPINDLE RM
TOOL RM
TOOL RM
1ST FLOOR PLAN BEFORE CHANGE 1
_ SCALE: 1/32" = 1-0"
ARCH D 050 FT 100 FT 150 FT 200 FT
EL. 26-0"
BUS DUCT "E1-3D"
400 AMPS 480V, 3PH, 3W
EL. 27-0"
BUS DUCT "E1-3B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W EL. 27-0"
BUS DUCT "E1-3C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E1-3F"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-1B"
400 AMPS 480/277V, 3PH, 4W
EL. 27-6"
BUS DUCT "E1-1C"
3PH, 4W
400 AMPS 480/277V,
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
PWR-E-5/A
100/100
100/100
400/400
400/400
400/400
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
EL. 26-0"
BUS DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
RCP-E-7/C
TRANSFORMER
3PH, 4W
30KVA, 120/208V,
60/45
400/400
EL. 26-0"
BUS DUCT "E1-3E"
400 AMPS 480V, 3PH, 3W
400/400
LTG-E-3/C
LTG-E-7/C
LTG-E-6/F
LTG-E-6/J
LTG-E-3/J
LTG-E-3/F
200/200
TO PWR-E-7/D
100/100
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
400/300
TO PWR-E-6/A
F
F
F
F
F
F
F
T
F
F
F F
F
F F
F
TR RCP-K-10
LTG-K-10
F
100/100
100/100
100
100/
100
100/
EL. 26-0"
BUS DUCT "E3-1A"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1E"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1G"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1"
2500 AMPS 480V, 3PH, 3W
400/400
400/400
400/400
400/400
EL. 26-0"
BUS DUCT "E3-1F"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1D"
400 AMPS 480V, 3PH, 3W
400/400
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
400/400
400/400
EL. 26-0"
BUS DUCT "E3-1C"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
PWR-E-1/K
100/100
EL. 27-6"
BUS DUCT "E3-1"
2500 AMPS 480V, 3PH, 3W
600/600
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
400/400
400/400
F
F
F
F F F F
F
EPS PWD-E-1/H
OFFICE AREA POWER
DISTRIBUTION PANEL
F
EL. 26-0"
BUS DUCT "E1-3D"
400 AMPS 480V, 3PH, 3W
EL. 27-0"
BUS DUCT "E1-3B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W EL. 27-0"
BUS DUCT "E1-3C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E1-3F"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-1B"
400 AMPS 480/277V, 3PH, 4W
EL. 27-6"
BUS DUCT "E1-1C"
3PH, 4W
400 AMPS 480/277V,
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
PWR-E-5/A
100/100
100/100
400/400
400/400
400/400
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
EL. 26-0"
BUS DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
RCP-E-7/C
TRANSFORMER
3PH, 4W
30KVA, 120/208V,
60/45
400/400
EL. 26-0"
BUS DUCT "E1-3E"
400 AMPS 480V, 3PH, 3W
400/400
LTG-E-3/C
LTG-E-7/C
LTG-E-6/F
LTG-E-6/J
LTG-E-3/J
LTG-E-3/F
200/200
TO PWR-E-7/D
100/100
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
400/300
TO PWR-E-6/A
F
F
F
F
F
F
F
T
F
F
F F
F
F F
F
TR RCP-K-10
LTG-K-10
F
100/100
100/100
100
100/
100
100/
EL. 26-0"
BUS DUCT "E1-3D"
400 AMPS 480V, 3PH, 3W
EL. 27-0"
BUS DUCT "E1-3B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W EL. 27-0"
BUS DUCT "E1-3C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E1-3F"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-1B"
400 AMPS 480/277V, 3PH, 4W
EL. 27-6"
BUS DUCT "E1-1C"
3PH, 4W
400 AMPS 480/277V,
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
PWR-E-5/A
100/100
100/100
400/400
400/400
400/400
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
EL. 26-0"
BUS DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
RCP-E-7/C
TRANSFORMER
3PH, 4W
30KVA, 120/208V,
60/45
400/400
EL. 26-0"
BUS DUCT "E1-3E"
400 AMPS 480V, 3PH, 3W
400/400
LTG-E-3/C
LTG-E-7/C
LTG-E-6/F
LTG-E-6/J
LTG-E-3/J
LTG-E-3/F
200/200
TO PWR-E-7/D
100/100
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
400/300
TO PWR-E-6/A
F
F
F
F
F
F
F
T
F
F
F F
F
F F
F
TR RCP-K-10
LTG-K-10
F
100/40
100/100
100/100
100
100/
100
100/
EL. 26-0"
BUS DUCT "E2-1A"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1D"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1F"
400 AMPS 480V, 3PH, 3W
400/400
400/400
EL. 27-6"
BUS DUCT "E2-1"
3W 2500 AM
PS 480V, 3PH,
400/400
400/400
400/400
400/400
EL. 26-0"
BUS DUCT "E2-1B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1E"
400 AMPS 480V, 3PH, 3W
600/600
100/100
400/400
F F F F F F F F
F
PWR-E-10/K
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
MEZZAINE LEVEL
ENGINE TEST RM.
TO PWD-E-6/L
F0R TEST CELLS
TRANSFORMER
TO ISOLATION
ELEV. 30-0"
12" WIDE 15KV CABLE TRAY
E-E-425 FOR LOCATION
SUBSTATION ROOM - SEE DRAWING
PANEL EPWD-400 LOCATED IN ELECTRICAL
2-4"C TO 480V EMERGENCY DISTRIBUTION
RELOCATION OF AN EXISTING DEMOLITION
ELEV. 30-0"
12" WIDE 15KV CABLE TRAY
DOWN
SLOPE E-E-425 FOR LOCATION
SUBSTATION ROOM - SEE DRAWING
PANEL EPWD-400 LOCATED IN ELECTRICAL
2-4"C TO 480V EMERGENCY DISTRIBUTION
13.8KV-480/277V
E-4 OIL TYPE 2000KVA
ELEV. 28-0"
12" WIDE 15KV CABLE TRAY
AL. DUCT
E-V-4
EV-4
ELEV. 30-0"
12" WIDE 15KV CABLE TRAY
ELEV. 28-0"
12" WIDE 15KV CABLE TRAY
DOWN
SLOPE E-E-425 FOR LOCATION
SUBSTATION ROOM - SEE DRAWING
PANEL EPWD-400 LOCATED IN ELECTRICAL
2-4"C TO 480V EMERGENCY DISTRIBUTION
13.8KV-480/277V
E-4 OIL TYPE 2000KVA
ELEV. 28-0"
12" WIDE 15KV CABLE TRAY
AL. DUCT
E-V-4
EV-4
2500 AMPS 480V, 3PH, 3W FEEDER BUS "E3-1" EL. 26-0"
2500 AMPS 480V, 3PH, 3W
FEEDER BUS "E2-1" EL. 26-0"
CAPACTOR
CELLULAR PANEL
500KVA 480-480/277V 3P
4WFOR LIGHTING
CAPACTOR
CAPACTOR
480/277V 3P 4WUPS FOR EMERGENCY LIGHTING SYSTEM
480/277V 3P 4WBATTERY FOR EMERGENCY EMS SYSTEM
EPWD-400
O-MV-1 PRIMARY 1200A 15KV
13.8KV-480/277V E-1 2000KVA
13.8KV-480/277V E-3 2000KVA
13.8KV-480/277V E-2 2000KVA
EPWD-E-7/E
PWR-MES-E
PWR-E-7/D
480/277V 3P 4WUPS FOR EMERGENCY EMS SYSTEM
2500 AMPS 480V, 3PH, 3W FEEDER BUS "E1-3" EL. 27-6"
12" WIDE 15KV CABLR TRAY ELEV. 28
FOR CONTINUATION FOR CONTINUATION
PWR-E-10/C
T
H
E
re
lo
c
a
tio
n
a
n
d
d
e
m
o
litio
n
re
u
s
e
d
T
H
E
re
lo
c
a
tio
n
a
n
d
d
e
m
o
litio
n
re
u
s
e
dT
H
E
re
lo
c
a
tio
n
a
n
d
d
e
m
o
litio
n
re
u
s
e
d
T
H
E
re
lo
c
a
tio
n
a
n
d
d
e
m
o
litio
n
re
u
s
e
d
T
H
E
re
lo
c
a
tio
n
a
n
d
d
e
m
o
litio
n
re
u
s
e
d

After demolition Return

After demolition Return
PWR-E-6/A
1
IM-E-301
01 IN = 32 FT 200 100
OVERALL PLAN- POWER DISTRIBUTION BEFORE
ALTERATIONS
BEFORE
POWER DISTB.
OVERALL PLAN
SEE ONE-LINE GENERAL ELECTRICAL NOTES
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING AREAS THAT
CLOUDED ITEMS INDICATE
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4
-
0
"
48-0" 64-0" 64-0 1/16" 64-0" 64-0" 62-0" 64-0" 64-0" 64-0" 64-0" 2-0"
624-0"
5
7
6
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
10
A B D E F G H J K L C
9
8
7
6
5
4
3
2
1
Fx
301 A
2
CELL1
PURITY PARTS
STORAGE
OFFICE
CONF. RM
COOLANT(LOWER)
ENGING TEST
ES TEST RM
SUB-MATERIAL RM
MIP
112
SHOP
101
CALIBRATION
114
TOOL ROOM
115
BREAK RM
130
LOCKER RM(W)
LOCKER RM(M)
REST RM(W)
REST RM(M)
RAWMATERIAL AREA
120
MAINTENANCE OFFICE
122
MAINTENANCE PARTS AREA
REST RM(W)
124
REST RM(M)
125
123
DIS-ASSEMBLY
119
MACHINING AREA
121
CONF. RM
110
ARCHIVE
111
SHIPPING/ RECEIVING
102
SHOWER RM(M)
136
SHOWER RM(W)
135
131
IT RM
138
132
133
134
137
JANITOR RM
JANITOR RM
126
MIP & CAL.
113
VESTIBULE
103
CELL2
MAT. LAB
118
A 402
1
A 401
1
A 403
1
TOOL ROOM
116
TOOL AREA
117
OFFICE
301 A
1
42-8"
UPS
140
ELEC. RM
141
Ax
A 404
1
BLOCK
CRANK
HEAD
ASSEMBLY
HEAD SUB
CMM
CMM
CMM
CMM
CMM
CMM
SURFACE PLATECMM
CMM
CMM
FMS
FMS
GAGE CAB GAGE CAB GAGE CAB GAGE CAB
CUBICLE
CUBICLE
CUBICLE
CUBICLE
FIRE CAB
T8000T8000 OPTIC
CFMCFM
BlockLambda
HeadLambda
Crank & Assy
Lambda
Plate Warming
600 Mahr PLM
Plate Surface
Instrument Storage
Plate Surface
Loader Torque
EngraverLaser
FilterLaserStandTorque
Bench Electrical Bench Pressure Inora Faro pod Tri
Storage
Instrument Storage
Instrument Storage
Instrument Storage
Plate Surface
Cart
Cart
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
FilesCompGage Block
Cabinet Shoe Case Book
CUBICLE
CUBICLE
Shower Air
Copier
Cart
Cart
Cart
Cart
Cart
Cart
Files
Files
1/4 Ton Hoist
1/4 Ton Hoist
1/4 Ton Hoist
1/4 Ton Hoist
Zoller
Wheel Rack
UNISET - v
Movable Hoist
Turn Mill Setting
UNISET - H
Washing M/C Power House
Movable Hoist
Tool CabinetGranite Table
Tool Cabinet
1 ton 1 ton
1 ton
1 ton 0.5 ton 0.7 ton
2 ton
0.5 ton
SVP3 G/D M/C 1 ton
Grinder
Zoller
1 ton
Zoller
1 ton
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD SD SD
SD SD SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
SDSD SDSD SDSD SDSD
SD SD SD SD SD SD SD SD
SD SDSD SDSD SDSD SD
SD SD SD SD SD SD SD SD
10
9
8
7
6
5
4
3
2
1
A 404
1
A B D E F G H J K L C Fx
RELOCATED SHUTTER
NEWMAN DOOR
RELOCATED VESTIBULE
OFFICE
100/100
100/100
F
F
T
F
F
100/100
100/100
F
F
T
F
F
100/100
100/100
F
F
T
F
F
EL. 27-6"
BUS DUCT "E2-1"
3W 2500 AM
PS 480V, 3PH,
100/100
F F
F0R TEST CELLS
TRANSFORMER
TO ISOLATION
ELEC.RM
141
UPS
140
E1 E2 E4 E3 E5 E6 E- MV1 PRO BLA
2-0"
F
F
F
T
TC100D
PWD-E-K/9(MAIN PANEL)
PWR-E-K/9(FOR VAVS & MECH. EQUI.)
LP-E-K/9(LIGHTING PANEL)
TR-E-K/9
RCP-E-K/9(RECEPTACLE PANEL)
SEE NOTE "1"
LTG-K-10
EL. 27-0"
DUCT "E1-3B"
400 AMPS 480V, 3PH, 3W
BUS
400 AMPS 480/277V, 3PH, 4W
BUS DUCT "E1-1A"
EL. 26-0"
2500 AMPS 480V, 3PH, 3W
EL. 29
BUS DUCT "E6-1"
2500 AMPS 480V, 3PH, 3W
BUS DUCT "E5-1"
EL. 29
SEE NOTE "2"
LTG-E-7/C
RCP-E-7/C
4W
TRANSFORMER
30KVA, 120/208V, 3PH,
60/45
EL. 28
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
12" WIDE 15KV CABLE TRAY
ELEV. 30-0"
2000 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-3"
ELEV. 30-0"
12" W
IDE 15KV CABLE TRAY
DOW
N
SLOPE
SEE NOTE "2"
TO PW
R-E-6/A
EL. 26-0"
BUS DUCT "E1-3D"
400 AMPS 480V, 3PH, 3W
FOR LOCATION
SUBSTATION ROOM - SEE DRAWING E-E-425
PANEL EPWD-400 LOCATED IN ELECTRICAL
2-4"C TO 480V EMERGENCY DISTRIBUTION
PWR-E-6/A
SEE NOTE "4"
E-LV-5 E-LV-6
E-LV-3 E-LV-2
E-LV-1
400Y
EL. 29
1350 AMPS 480V, 3PH, 3W
BUS DUCT "E6-1-1A"
EL. 28"
BUS DUCT "E1-1B,1C" CONNECTION
400 AMPS 480/277V, 3PH, 4W
1600/1350 1600/1350
400Y
1600D
400D
EL. 27-6"
BUS DUCT "E1-1B"
400 AMPS 480/277V, 3PH, 4W
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
400/400
400/400
EL. 26-0"
BUS DUCT "E2-1A"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1B"
400 AMPS 480V, 3PH, 3W
100/100
100Y
SEE NOTE "2"
LTG-E-6/F
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
ELEV. 28-0"
12" WIDE 15KV CABLE TRAY
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
400/400
400/400
1600D F
F
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
F
F
LTG-E-6/J
F
F
100/40
100/100
EL. 26-0"
BUS DUCT "E2-1D"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1F"
400 AMPS 480V, 3PH, 3W
400/400
400/400
400/400
400/400
EL. 26-0"
BUS DUCT "E2-1C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1E"
400 AMPS 480V, 3PH, 3W
600/600
400/400
F F F F F F
F
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
100Y
SEE NOTE "2"
EL. 26-0"
600D
600D
F
RCP-E-TC#3
RCP-E-TC#2
1st FL LEVEL
ENGINE TEST RM.
TO PWD-E-6/L
112.5 KVA
480-120/208V 3PH,4W
RCP-WD-E-6/L
PWR-E-6/L
RCP-E-6/L
CRCP-E-6/L
LTG-E-6/L
RCP-E-TC#1
SEE NOTE "2"
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
100/100
400/400
400/400
400/400
400/400
EL. 26-0"
DUCT "E1-3E"
400 AMPS 480V, 3PH, 3W
BUS
400/400
400/400
LTG-E-3/C
400/300
F
F
F
F
F
F
F F
EL. 27-6"
BUS DUCT "E3-1"
2500 AMPS 480V, 3PH, 3W
F
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
100/100
400/400
400/400
400/400
400/400
EL. 26-0"
DUCT "E1-3E"
400 AMPS 480V, 3PH, 3W
BUS
400/400
400/400
LTG-E-3/C
400/300
F
F
F
F
F
F
F F
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
100/100
400/400
400/400
400/400
400/400
EL. 26-0"
DUCT "E1-3E"
400 AMPS 480V, 3PH, 3W
BUS
400/400
400/400
LTG-E-3/C
400/300
F
F
F
F
F
F
F F
1600D
EL. 27-6"
BUS DUCT "E1-1C"
4W 400 AMPS 480/277V, 3PH,
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
100
100/
EL. 26-0"
BUS DUCT "E3-1A"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1E"
400 AMPS 480V, 3PH, 3W
400/400
400/400
400/400
EL. 26-0"
BUS DUCT "E3-1D"
400 AMPS 480V, 3PH, 3W
400/400
400/400
EL. 26-0"
BUS DUCT "E3-1C"
400 AMPS 480V, 3PH, 3W
600/600 F
F
F F F F
EL. 27-6"
BUS DUCT "E1-1C"
4W 400 AMPS 480/277V, 3PH,
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
100
100/
EL. 27-6"
BUS DUCT "E1-1C"
4W 400 AMPS 480/277V, 3PH,
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
F
100
100/
2500 AMPS 480V, 3PH, 3W
BUS DUCT "E5-1"
EL. 29
400Y
TC100Y
100
100/
EL. 26-0"
BUS DUCT "E3-1G"
400 AMPS 480V, 3PH, 3W
400/400
EL. 26-0"
BUS DUCT "E3-1F"
400 AMPS 480V, 3PH, 3W
400/400 F
100
100/F
100
100/
E-V-4
AL. DUCT
E-V-4
EV-4
2500 AMPS 480V, 3PH, 3W
BUS DUCT "E5-1"
EL. 29
TC100Y
ELEV. 28-0"
12" WIDE 15KV CABLE TRAY
T
F
LP-E-4/K
TR-E-4/K
RCP-E-4/K
SEE NOTE "6"
100/80
13.8KV-480/277V
2000KVA
OIL TYPE
E-4 TRANSF
EL. 26-0"
DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
BUS
EL. 27-0"
BUS DUCT "E1-3C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
DUCT "E1-3F"
400 AMPS 480V, 3PH, 3W
BUS
LTG-E-3/J
LTG-E-3/F
EL. 27-6"
BUS DUCT "E3-1"
2500 AMPS 480V, 3PH, 3W
EL. 26-0"
DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
BUS
EL. 27-0"
BUS DUCT "E1-3C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
DUCT "E1-3F"
400 AMPS 480V, 3PH, 3W
BUS
LTG-E-3/J
LTG-E-3/F
EL. 26-0"
DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
BUS
EL. 27-0"
BUS DUCT "E1-3C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
DUCT "E1-3F"
400 AMPS 480V, 3PH, 3W
BUS
LTG-E-3/J
LTG-E-3/F
1350 AMPS 480V, 3PH, 3W
BUS DUCT "E6-1-1A"
EL. 29
100/100
F
SEE NOTE "2" SEE NOTE "2"
T
3P 480-120/208V
PWR-E-1/A(FOR VAVS & MECH. EQUI.)
SEE NOTE "5"
FFF
FFF
100/50
100/100
225/150
MES-E-1/A
LP-E-1/A
TR-E-1/A
RCP-E-1/A
F F
1. SEE DWG. NO IM-E-317 FOR ENLAGED POWER PLAN
2. EXISTING NO CHANGE LOCATION.
3. NEWBUSWAY.
4. CABLE & CONDUIT SIZE FOR SEE DWG NO IM-E-112.
ENLARGED SUB STATION PLAN.
5. CABLE & CONDUIT SIZE FOR SEE DWG NO IM-E-303~320.
ENLARGED POWER PLAN.
MI-E-104 BUSDUCT RISER DIAGRAM.
MI-E-105 BUSDUCT RISER DIAGRAM.
MI-E-106 BUSDUCT RISER DIAGRAM.
MI-E-107 BUSDUCT RISER DIAGRAM.
MI-E-108 BUSDUCT RISER DIAGRAM.
6. THE BUSDUCT & PLUG IN DEVICE RE-USE THE EXISTING.
IS THE RESPONSIBILITY OF THE OWNER / HMMA.
CABLE TRAY, ETC. IS OT IN THIS CONTRACT SCOPE AND
8. THE EMS POWER DISTRIBUTION, CABLING,CONDUIT,
7. REFER TO CABLE & CONDUIT SCHEDULE FOR SIZES
DRAWING ELECTRICAL NOTES
SEE NOTE #2
PW
R/E/K01
1 01 IN = 32 FT 200 100
IM-E-302
OVERALL PLAN- POWER DISTRIBUTION AFTER CHANGES
AFTER
POWER DISTB.
OVERALL PLAN
SEE ONE-LINE GENERAL ELECTRICAL NOTES
SEE NOTE #2
PWR-E-10/C SEE NOTE #2
PWR-E-10/K
SEE NOTE #2
PWR/E/A05
600AF/600T
TEST CELL SUPPLIER
PROVIDED & INSTALLED BY
350 KVA ISO. TRANSFORMER
TEST CELL SUPPLIER
PROVIDED & INSTALLED BY
TEST CELL PANEL
13.8KV-480/277V
2000KVA
OIL TYPE
E-4 TRANSF
E-V-4
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING AREAS THAT
CLOUDED ITEMS INDICATE
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4

-
0
"
48-0" 64-0"
64-0 1/16"
64-0" 64-0" 62-0" 2-0"
624-0"
6
4

-
0
"
A B D E F C Fx
SHIPPING/ RECEIVING
102
OFFICE
42-8"
UPS
140
Ax
SD SD SD SD SD SD SD SD SD SD SD SD
RELOCATED SHUTTER
NEW MAN DOOR
OFFICE
1
0
0
/
1
0
0
F
F
T
F
1
0
0
/
1
0
0
F
F
T
F
1
0
0
/
1
0
0
F
F
T
F
F F
UPS
140
2
-
0
"
E
L
. 2
7
-0
"
D
U
C
T
"
E
1
-3
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
B
U
S
D
U
C
T
"
E
1
-1
A
"
E
L
. 2
6
-0
"
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
9

B
U
S
D
U
C
T
"
E
6
-1
"
2500 AMPS 480V, 3PH, 3W
BUS DUCT "E5-1"
EL. 29
SEE NOTE "2"
L
T
G
-E
-7
/C
R
C
P
-E
-7
/C
4
W
T
R
A
N
S
F
O
R
M
E
R
3
0
K
V
A
, 1
2
0
/2
0
8
V
, 3
P
H
,
6
0
/4
5
400Y
EL. 29
1350 AMPS 480V, 3PH, 3W
BUS DUCT "E6-1-1A"
EL. 28"
BUS DUCT "E1-1B,1C" CONNECTION
400 AMPS 480/277V, 3PH, 4W
1600D
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
4
0
0
/4
0
0
4
0
0
/4
0
0
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
SEE NOTE #2
PWR-E-10/C
IM-E-303
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
ENLARGED PWR DISTB. AFTER - SECTOR 01
SECTOR-01
AFTER ALTERATIONS
POWER DISTB.
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
62-0" 64-0" 64-0" 64-0" 64-0" 2-0"
624-0"
F G H J K L Fx
ES TEST RM
MIP
112
CALIBRATION
114
TOOL ROOM
115
CONF. RM
110
ARCHIVE
111
SHIPPING/ RECEIVING
102
MIP & CAL.
113
MAT. LAB
118
TOOL ROOM
116
TOOL AREA
117
301 A
1
HEAD SUB
CMM
CMM
CMM
C
M
M
C
M
M
C
M
M
SURFACE
PLATECMM
CMM
CMM
F
M
S
FMS
GAGE CAB GAGE CAB GAGE CAB GAGE CAB
CUBICLE
CUBICLE
CUBICLE
CUBICLE
FIRE CAB
T8000T8000
OPTIC
C
F
MCFM
Block
Lambda
Head
Lambda
Crank & Assy
Lambda
Plate Warming
600 Mahr PLM
Plate Surface
Instrument Storage
Plate Surface
Loader Torque
Engraver
Laser
Filter
Laser
Stand
Torque
Bench Electrical
Bench Pressure Inora Faro
pod Tri
Storage
Instrument Storage
Instrument Storage
Instrument Storage
Plate Surface
Cart
Cart
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Comp
Gage Block
Cabinet Shoe Case Book
CUBICLE
CUBICLE
Shower
Air
Copier
Cart
Cart
Cart
Cart
Cart
Cart
Files
Files
1/4 Ton
Hoist
1/4 Ton
Hoist
1/4 Ton
Hoist
1/4 Ton
Hoist
Zoller
Wheel Rack
UNISET - v
Movable Hoist
Turn M
ill Setting
UNISET - H
Washing M/C Power House
Movable Hoist
Tool Cabinet
Granite Table
Tool Cabinet
1 ton 1 ton
1 ton
1 ton 0.5 ton
0.7 ton
2 ton
0.5 ton
SVP3 G/D M/C
1 ton
Grinder
Zoller
1 ton
Zoller
1 ton
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
SD SD SD SD SD SD SD SD
10
9
8
7
A 404
1
RELOCATED SHUTTER
NEW MAN DOOR
1
0
0
/
1
0
0
1
0
0
/
1
0
0
1
0
0
/
1
0
0
E
L
. 2
7
-
6
"
B
U
S
D
U
C
T
"
E
2
-
1
"
3
W
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
,
1
0
0
/1
0
0
F
F0R TEST CELLS
TRANSFORMER
TO ISOLATION
T
T
C
1
0
0
D
PWD-E-K/9(MAIN PANEL)
PWR-E-K/9(FOR VAVS & MECH. EQUI.)
LP-E-K/9(LIGHTING PANEL)
TR-E-K/9
RCP-E-K/9(RECEPTACLE PANEL)
SEE NOTE "1"
LTG-K-10
4
0
0
/4
0
0
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
6
0
0
/6
0
0
4
0
0
/4
0
0
F F F F F F
F
6
0
0
D
F
RCP-E-TC#3
SEE NOTE #2
PWR-E-10/K
600AF/600T
TEST CELL SUPPLIER
PROVIDED & INSTALLED BY
350 KVA ISO. TRANSFORMER
TEST CELL SUPPLIER
PROVIDED & INSTALLED BY
TEST CELL PANEL
IM-E-304
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
ENLARGED PWR DISTB. AFTER - SECTOR 02
SECTOR-02
AFTER ALTERATIONS
POWER DISTB.
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
SHOP
42-8"
UPS
140
ELEC. RM
141
Ax
ASSEMBLY
F
F
T
F
F
F
T
F
F
F
T
F
ELEC.RM
141
UPS
140
E1
E2
E4
E3
E5
E6
E-
MV1
PRO
BLA
2
-
0
"
F
F
F
E
L
. 2
7
-0
"
D
U
C
T
"
E
1
-3
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
B
U
S
D
U
C
T
"
E
1
-1
A
"
E
L
. 2
6
-0
"
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
9

B
U
S
D
U
C
T
"
E
6
-1
"
2500 AMPS 480V, 3PH, 3W
BUS DUCT "E5-1"
EL. 29
SEE NOTE "2"
L
T
G
-E
-7
/C
R
C
P
-E
-7
/C
4
W
T
R
A
N
S
F
O
R
M
E
R
3
0
K
V
A
, 1
2
0
/2
0
8
V
, 3
P
H
,
6
0
/4
5
EL. 28
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
12" WIDE 15KV CABLE TRAY
ELEV. 30-0"
2000 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-3"
E
L
E
V
. 3
0
-0
"
1
2
"
W
ID
E
1
5
K
V
C
A
B
L
E
T
R
A
Y

D
O
W
N
S
L
O
P
E
SEE NOTE "2"
T
O
P
W
R
-E
-6
/A
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
1
-3
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
FOR LOCATION
SUBSTATION ROOM - SEE DRAWING E-E-425
PANEL EPWD-400 LOCATED IN ELECTRICAL
2-4"C TO 480V EMERGENCY DISTRIBUTION
PWR-E-6/A
SEE NOTE "4"
E-LV-5 E-LV-6
E-LV-3 E-LV-2
E-LV-1
400Y
EL. 28"
BUS DUCT "E1-1B,1C" CONNECTION
400 AMPS 480/277V, 3PH, 4W
1600/1350
1600/1350
400Y
1600D
400D
EL. 27-6"
BUS DUCT "E1-1B"
400 AMPS 480/277V, 3PH, 4W
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
100/100
100Y
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
ELEV. 28-0"
12" WIDE 15KV CABLE TRAY
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
400/400
400/400
1600D
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-3
"
2
0
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
1
0
0
/1
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/3
0
0
F
F
F
F
F
F F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
3
-1
"
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-3
"
2
0
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
1
0
0
/1
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/3
0
0
F
F
F
F
F
F F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-3
"
2
0
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
1
0
0
/1
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/4
0
0
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

4
0
0
/4
0
0
4
0
0
/4
0
0
4
0
0
/3
0
0
F
F
F
F
F
F F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
2500 AMPS 480V, 3PH, 3W
BUS DUCT "E5-1"
EL. 29
4
0
0
Y
SEE NOTE #2
PWR/E/A05
IM-E-305
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
ENLARGED PWR DISTB. AFTER - SECTOR 03
SECTOR-03
AFTER ALTERATIONS
POWER DISTB.
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
CELL1
PURITY PARTS
STORAGE
OFFICE
CONF. RM
COOLANT(LOWER)
ENGING TEST
ES TEST RM
SUB-MATERIAL RM
SHOP
101
RAW MATERIAL AREA
120
MAINTENANCE OFFICE
DIS-ASSEMBLY
119
MACHINING AREA
121
CELL2
MAT. LAB
118
A 401
1
CRANK
HEAD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
A 404
1
FFF
F0R TEST CELLS
TRANSFORMER
TO ISOLATION
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
100/100
100Y
SEE NOTE "2"
LTG-E-6/F
F
F
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
F
F
LTG-E-6/J
F
F
100/40
100/100
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
6
0
0
/6
0
0
4
0
0
/4
0
0
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
100Y
SEE NOTE "2"
E
L
. 2
6
-0
"
6
0
0
D
6
0
0
D
F
RCP-E-TC#3
RCP-E-TC#2
1st FL LEVEL
ENGINE TEST RM.
TO PWD-E-6/L
112.5 KVA
480-120/208V 3PH,4W
RCP-WD-E-6/L
PWR-E-6/L
RCP-E-6/L
CRCP-E-6/L
LTG-E-6/L
RCP-E-TC#1
SEE NOTE "2"
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
W
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
,
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
W
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
,
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
W
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
,
2500 AMPS 480V, 3PH, 3W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
G
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E-V-4
AL. DUCT
E-V-4
2500 AMPS 480V, 3PH, 3W
BUS DUCT "E5-1"
EL. 29
ELEV. 28-0"
12" WIDE 15KV CABLE TRAY
T
LP-E-4/K
TR-E-4/K
RCP-E-4/K
SEE NOTE "6"
13.8KV-480/277V
2000KVA
OIL TYPE
E-4 TRANSF
600AF/600T
TEST CELL SUPPLIER
PROVIDED & INSTALLED BY
350 KVA ISO. TRANSFORMER
TEST CELL SUPPLIER
PROVIDED & INSTALLED BY
TEST CELL PANEL
13.8KV-480/277V
2000KVA
OIL TYPE
E-4 TRANSF
IM-E-306
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
ENLARGED PWR DISTB AFTER - SECTOR 04
1 AS SHOWN 75 50 25
SECTOR-04
AFTER ALTERATIONS
POWER DISTB.
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
301 A
2
BREAK RM
130
LOCKER RM(W)
LOCKER RM(M)
REST RM(W)
REST RM(M)
SHOWER RM(M)
136
SHOWER RM(W)
135
131
IT RM
138
132
133
134
137
JANITOR RM
VESTIBULE
103
A 403
1
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
A B D E F C Fx
RELOCATED VESTIBULE
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-3
"
2
0
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

L
T
G
-E
-3
/C
F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
3
-1
"
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-3
"
2
0
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

L
T
G
-E
-3
/C
F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-3
"
2
0
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

L
T
G
-E
-3
/C
F
1600D
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
1
0
0
1
0
0
/
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
4
0
0
/4
0
0
4
0
0
/4
0
0F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
1
0
0
1
0
0
/
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
F
1
0
0
1
0
0
/
4
0
0
Y
T
C
1
0
0
Y
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-1
A
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
B
U
S

E
L
. 2
7
-0
"
B
U
S
D
U
C
T
"
E
1
-3
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

L
T
G
-E
-3
/F
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-1
A
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
B
U
S

E
L
. 2
7
-0
"
B
U
S
D
U
C
T
"
E
1
-3
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

L
T
G
-E
-3
/F
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-1
A
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
B
U
S

E
L
. 2
7
-0
"
B
U
S
D
U
C
T
"
E
1
-3
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

L
T
G
-E
-3
/F
1350 AMPS 480V, 3PH, 3W
BUS DUCT "E6-1-1A"
EL. 29
SEE NOTE "2"
T
3P 480-120/208V
PWR-E-1/A(FOR VAVS & MECH. EQUI.)
SEE NOTE "5"
FFF
FFF
1
0
0
/5
0
1
0
0
/1
0
0
2
2
5
/1
5
0
MES-E-1/A
LP-E-1/A
TR-E-1/A
RCP-E-1/A
F
IM-E-307
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-05
AFTER ALTERATIONS
POWER DISTB
ENLARGED
ENLARGED PWR DISTB. AFTER - SECTOR 05
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
COOLANT(LOWER)
120
MAINTENANCE OFFICE
122
MAINTENANCE PARTS AREA
REST RM(W)
124
REST RM(M)
125
123
MACHINING AREA
121
JANITOR RM
126
A 402
1
BLOCK
CRANK
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
F G H J K L Fx
RELOCATED VESTIBULE
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
W
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
,
1
0
0
1
0
0
/
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
4
0
0
/4
0
0
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
4
0
0
/4
0
0
4
0
0
/4
0
0
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
6
0
0
/6
0
0
F F F F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
W
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
,
1
0
0
1
0
0
/
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
W
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
,
F
1
0
0
1
0
0
/
T
C
1
0
0
Y
1
0
0
1
0
0
/
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
G
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
400/400
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
4
0
0
/4
0
0 F
1
0
0
1
0
0
/F
1
0
0
1
0
0
/
E-V-4
AL. DUCT
E-V-4
EV-4
T
C
1
0
0
Y
T
F
LP-E-4/K
TR-E-4/K
RCP-E-4/K
SEE NOTE "6"
100/80
13.8KV-480/277V
2000KVA
OIL TYPE
E-4 TRANSF
L
T
G
-E
-3
/J
L
T
G
-E
-3
/F
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
3
-1
"
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
L
T
G
-E
-3
/J
L
T
G
-E
-3
/F
L
T
G
-E
-3
/J
L
T
G
-E
-3
/F
1350 AMPS 480V, 3PH, 3W
BUS DUCT "E6-1-1A"
1
0
0
/1
0
0
F
SEE NOTE "2" SEE NOTE "2"
F F
S
E
E
N
O
T
E
#
2
P
W
R
/E
/K
0
1
13.8KV-480/277V
2000KVA
OIL TYPE
E-4 TRANSF
E-V-4
IM-E-308
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-06
AFTER ALTERATIONS
POWER DISTB
ENLARGED ENLARGED PWR. DISTB. AFTER - SECTOR 06
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
BLOCK
CRANK
HEAD HEAD-SUB
ASSEMBLY
COOLANT
6
4
-
0
"
48-0" 64-0" 64-0 1/16" 64-0" 64-0" 62-0" 64-0" 64-0" 64-0" 64-0"
ELEC. ROOM
MEASURING RM
CALIBRATION RM
MATERIAL AREA
CELL3
CELL2
CELL1
OFFICE
CONF. RM
SUB-MATERIAL RM
BREAK RM OPEN OFFICE
2-0"
624-0"
5
7
6
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
SHIPPING/ RECEIVING
10
A B D E F G H J K L C
9
8
7
6
5
4
3
2
1
Fx
SHIPPING/ RECEIVING
PURITY PARTS
STORAGE
ENGINE TEST
TOOL RM
ES TEST RM
SPINDLE RM
TOOL RM
TOOL RM
1ST FLOOR PLAN BEFORE CHANGE 1
_ SCALE: 1/32" = 1-0"
ARCH D 050 FT 100 FT 150 FT 200 FT
50 50 50 50
50
60/60
50
50
50
100/100
RF-10HP
SF-30HP
95.6KW
30/20
F
F
HVAC
400-1
F
F
F
HVAC
400-13 HVAC
400-12
F
HVAC
400-11
F
F
CUH
400-1
HVAC
400-18
HVAC
400-10 VFD HVAC
400-9
HVAC
400-8
HVAC
400-7
RF-10HP
SF-30HP
95.6KW
F
VFD
F
F
CUH
VFD
F
F
F F
F
F
F
F
50 50
50
60/60
50
100/100
30/20
F
F
HVAC
400-1
F
F
F
HVAC
400-13 HVAC
400-12
F
HVAC
400-11
F
F
50
F
F
F
50
50
44.3KW
100/100
50
F F F
F F F F
F
F
HVAC
400-6
VFD
F
50
F F
F
F
100/100
F F
F F
F
F
100/100
F F
F
F
F
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
2500 AMPS 480V, 3PH, 3W
CAPACTOR
EMERGENCY EMS SYSTEM
CAPACTOR
PWR-MES-E
PWR-E-7/D
480/277V 3P 4WUPS FOR
480/277V 3P 4WBATTERY FOR
EMERGENCY EMS SYSTEM
4WFOR LIGHTING
480-480/277V 3P
500KVA
EPWD-E-7/E
EPWD-400
EMERGENCY LIGHTING SYSTEM
480/277V 3P 4WUPS FOR
PANEL
CELLULAR
EL. 26-0"
FEEDER BUS "E2-1"
2500 AMPS 480V, 3PH, 3W
CAPACTOR
FOR CONTINUATION
EL. 26-0"
FEEDER BUS "E3-1"
FOR CONTINUATION EL. 27-6"
FEEDER BUS "E1-3"
2500 AMPS 480V, 3PH, 3W
HAVC-400-20
FAN ON
RETURN
VFD FOR
MOUNT
EL. 26-0"
DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
BUS
EL. 27-0"
DUCT "E1-3B"
400 AMPS 480V, 3PH, 3W
BUS
60/60
ACCU
400-3
HVAC
400-3
HVAC
400-20
(ON MEZZANINE)
(ON ROOF)
57KW
57KW
RF-7.5HP
SF-15HP
100/90
60/45
HVAC REMOVE ROOF
HVAC(EXISTING)OUTSIDE
HVAC
400-1
400-2
HVAC
60/60
100/100
100/100
100/100
60/60
EL. 26-0"
BUS DUCT "E2-1D"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1A"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-1B"
400 AMPS 480/277V, 3PH, 4W
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1E"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1F"
400 AMPS 480V, 3PH, 3W
LTG-E-6/J
100/40
100/100
100/100
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
100/100
30/20
60/40
100/70
DWH-400-5
TOILET AREA
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
HVAC
400-4
ACCU
400-2
HVAC
400-19
HVAC
400-5
100/100
100/100
HAVC-400-19
RETURN FAN ON
MOUNT VFD FOR
RF-5HP
SF-15HP
50
50
400-1
HVAC
100/100
EL. 26-0"
BUS DUCT "E1-3D"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
30/20
TO DW
H-400-4
60/60
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
60/60
60/60
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
400-8
HVAC
400-7
HVAC
50
50
EL. 26-0"
BUS DUCT "E3-1G"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1F"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
EL. 26-0"
BUS DUCT "E3-1E"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1D"
400 AMPS 480V, 3PH, 3W
400/400
600/600
EL. 27-6"
BUS DUCT "E3-1"
2500 AMPS 480V, 3PH, 3W
60/60
100/100
LTG-E-3/J
100/100
100
100/
30/20
DWH-400-1
TOILET
100/70 100/100
EL. 26-0"
BUS DUCT "E3-1C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1B"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
EL. 26-0"
BUS DUCT "E3-1A"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1"
2500 AMPS 480V, 3PH, 3W
60/60
30/20
30/20
EL. 26-0"
DUCT "E1-3E"
400 AMPS 480V, 3PH, 3W
BUS
EL. 26-0"
DUCT "E1-3F"
400 AMPS 480V, 3PH, 3W
BUS
100/100
100/70
EL. 27-0"
BUS DUCT "E1-3C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
BUS
60/60
100/100
DWH-400-1
WOMEN LACKER
400-12
HVAC 400-13
HVAC
HVAC
400-11
50 50
50
F F
F
F
F
DO CP
F
F F
400-18
HVAC
400-10
HVAC
400-1
400-1
ACCU
400-9
HVAC
50 50
HVAC-400-18
RETURN FAN ON
MOUNT VFD FOR DISTRIBUTION PANEL
OFFICE AREA POWER
EPS PWD-E-1/H
(ON ROOF)
LTG-E-3/F
100
100/
100
100/
1 01 IN = 32 FT 200 100
IM-E-309
OVERALL PLAN- POWER BEFORE
ALTERATIONS
POWER BEFORE
OVERALL PLAN
TO FIELD VERIFY EXISTING CONDTIONS.
WORK BEFORE ANY MODIFICATIONS, CONTRACTOR
THIS PLAN SHOWTHE POWER PRESENET POWER
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4
-
0
"
48-0" 64-0" 64-0 1/16" 64-0" 64-0" 62-0" 64-0" 64-0" 64-0" 64-0" 2-0"
624-0"
5
7
6
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
10
A B D E F G H J K L C
9
8
7
6
5
4
3
2
1
Fx
301 A
2
CELL1
PURITY PARTS
STORAGE
OFFICE
CONF. RM
COOLANT(LOWER)
ENGING TEST
ES TEST RM
SUB-MATERIAL RM
MIP
112
SHOP
101
CALIBRATION
114
TOOL ROOM
115
BREAK RM
130
LOCKER RM(W)
LOCKER RM(M)
REST RM(W)
REST RM(M)
RAWMATERIAL AREA
120
MAINTENANCE OFFICE
122
MAINTENANCE PARTS AREA
REST RM(W)
124
REST RM(M)
125
123
DIS-ASSEMBLY
119
MACHINING AREA
121
CONF. RM
110
ARCHIVE
111
SHIPPING/ RECEIVING
102
SHOWER RM(M)
136
SHOWER RM(W)
135
131
IT RM
138
132
133
134
137
JANITOR RM
JANITOR RM
126
MIP & CAL.
113
VESTIBULE
103
CELL2
MAT. LAB
118
A 402
1
A 401
1
A 403
1
TOOL ROOM
116
TOOL AREA
117
OFFICE
301 A
1
42-8"
UPS
140
ELEC. RM
141
Ax
A 404
1
BLOCK
CRANK
HEAD
ASSEMBLY
HEAD SUB
CMM
CMM
CMM
CMM
CMM
CMM
SURFACE PLATECMM
CMM
CMM
FMS
FMS
GAGE CAB GAGE CAB GAGE CAB GAGE CAB
CUBICLE
CUBICLE
CUBICLE
CUBICLE
FIRE CAB
T8000T8000 OPTIC
CFMCFM
BlockLambda
HeadLambda
Crank & Assy
Lambda
Plate Warming
600 Mahr PLM
Plate Surface
Instrument Storage
Plate Surface
Loader Torque
EngraverLaser
FilterLaserStandTorque
Bench Electrical Bench Pressure Inora Faro pod Tri
Storage
Instrument Storage
Instrument Storage
Instrument Storage
Plate Surface
Cart
Cart
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
FilesCompGage Block
Cabinet Shoe Case Book
CUBICLE
CUBICLE
Shower Air
Copier
Cart
Cart
Cart
Cart
Cart
Cart
Files
Files
1/4 Ton Hoist
1/4 Ton Hoist
1/4 Ton Hoist
1/4 Ton Hoist
Zoller
Wheel Rack
UNISET - v
Movable Hoist
Turn Mill Setting
UNISET - H
Washing M/C Power House
Movable Hoist
Tool CabinetGranite Table
Tool Cabinet
1 ton 1 ton
1 ton
1 ton 0.5 ton 0.7 ton
2 ton
0.5 ton
SVP3 G/D M/C 1 ton
Grinder
Zoller
1 ton
Zoller
1 ton
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD SD SD
SD SD SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
SDSD SDSD SDSD SDSD
SD SD SD SD SD SD SD SD
SD SDSD SDSD SDSD SD
SD SD SD SD SD SD SD SD
10
9
8
7
6
5
4
3
2
1
A 404
1
A B D E F G H J K L C Fx
RELOCATED SHUTTER
NEWMAN DOOR
RELOCATED VESTIBULE
50
HVAC
400-8
RELOCATION OF SUBSTATION
ELEC.RM
141
HVAC
50
50
F
F
F
F
HVAC
400-8
50
F
F
F F F F F
F
F
F
F
HVAC
400-8
F
F
F
F
F
F
F
F
100/100
60/60
60/60
60/40F
F
F
F
VFD
100/100
F
F
F
FF
EL. 27-6"
BUS DUCT "E2-1"
3W 2500 AM
PS 480V, 3PH,
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
100/100
F 60/40
F
60/45
VFD
VFD
FFF
F
EXISTING
HVAC
RF-7.5HP
SF-15HP
VFD
F
400-21
HVAC
HVAC
400-1
HVAC
400-2
HVAC
400-3
HVAC
400-6
HVAC
400-22
50
50 50 50
50
50
ACCU
400-3
57KW
HVAC
400-4
HVAC
400-19
HVAC
400-5
RF-5HP
SF-15HP
100/100
100/90
60/40
30/20
100/100
DWH-400-5
TOILET AREA
F F F
F F F
TC90D
TC40D
TC90D
TC40D TC40D TC90D TC90D
TC90D
HVAC
EXISTING
EXISTING
HVAC TC40D
EXISTING
HVAC
TC90D
100/100
60/60
EL. 26-0"
DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
BUS
EL. 26-0"
BUS DUCT "E1-3D"
400 AMPS 480V, 3PH, 3W
PWR-MES-E-P1
PWR-ED-7/D-P1
PWR-ED-7/D-P2
PWR-ED-7/D-P3
E-LV-6 E-LV-5
E-LV-3
E-LV-2
E-LV-1
400-23 EF 3P 30A
3P 5KW
3P 5KW
400-22 EF 3P 30A
MV1 E2 E3 E6 BLA PRO E5 E4 E1 E-
3P 5KW
400-21 EF
3P 30A
400-20 EF 0.5KW
60/60
EL. 27-6" BUS DUCT "E1-3" 2000 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-1B"
400 AMPS 480/277V, 3PH, 4W
EL. 26-0"
BUS DUCT "E2-1A"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1D"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E2-1E"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
60/60
60/60
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
100/100
100/40
LTG-E-6/J
F
EL. 26-0"
BUS DUCT "E2-1F"
400 AMPS 480V, 3PH, 3W
HVAC
400-6
HVAC
400-7
50
50
100/100
EL. 26-0"
BUS DUCT "E3-1G"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1F"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1E"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1D"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1C"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E1-1C"
4W 400 AMPS 480/277V, 3PH,
100/100
100
100/
30/20
100/100
60/60
EL. 27-6"
BUS DUCT "E3-1"
2500 AMPS 480V, 3PH, 3W
LP-E-K-4/20,22,24
400-4
DWH
EF 400-2
400-9
HVAC
50 50
DO CP
400-1
400-10
HVAC
CUH
LTG-E-3/F
100/100
30/20
60/60
30/20
100
100/
EL. 27-6"
BUS DUCT "E1-1C"
400 AMPS 480/277V, 3PH, 4W
EL. 26-0"
BUS DUCT "E3-1B"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
BUS DUCT "E3-1A"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1"
2500 AMPS 480V, 3PH, 3W
200/150
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
EL. 27-0"
BUS DUCT "E1-3C"
400 AMPS 480V, 3PH, 3W
EL. 26-0"
DUCT "E1-3E"
400 AMPS 480V, 3PH, 3W
BUS
EL. 26-0"
DUCT "E1-3F"
400 AMPS 480V, 3PH, 3W
BUS
100/100
EL. 26-0"
DUCT "E1-1A"
400 AMPS 480/277V, 3PH, 4W
BUS
100/100
100/100
100/100
400-4
ACCU
95.6KW
400-1
400-18
400-11
HVAC
400-13
HVAC
400-12
HVAC
50
50
50
CAC
RF-10HP
SF-30HP
HVAC-400-18
RETURN FAN ON
MOUNT VFD FOR
T
C
1
5
0
D
TC90D
TC90D
TC90D
EXISTING
HVAC
EXISTING
HVAC
EXISTING
HVAC
TC90D
TC150D
TC90D
EXISTING
HVAC
EXISTING
HVAC
EXISTING
HVAC
TC90D
TC90D
TC90D
TC90D
EL. 27-0"
DUCT "E1-3B"
400 AMPS 480V, 3PH, 3W
BUS
DRAWING ELECTRICAL NOTES
1 01 IN = 32 FT 200 100
IM-E-310
CHANGES
POWER AFTER
OVERALL PLAN
OVERALL PLAN- POWER AFTER CHANGE
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING AREAS THAT
CLOUDED ITEMS INDICATE
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4

-
0
"
48-0" 64-0"
64-0 1/16"
64-0" 64-0" 62-0" 2-0"
624-0"
6
4

-
0
"
A B D E F C Fx
SHIPPING/ RECEIVING
102
OFFICE
42-8"
UPS
140
Ax
SD SD SD SD SD SD SD SD SD SD SD SD
RELOCATED SHUTTER
NEW MAN DOOR
50
FFF
1
0
0
/
1
0
0
6
0
/
6
0
6
0
/
4
0
F
F
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
1
0
0
/
1
0
0
F
400-21
HVAC
HVAC
400-1
HVAC
400-2
HVAC
400-3
50 50
TC90D
HVAC
EXISTING
EXISTING
HVAC
TC40D
EXISTING
HVAC
TC90D
1
0
0
/1
0
0
6
0
/6
0
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-1
A
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
B
U
S

E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
1
-3
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
PWR-MES-E-P1
3P 30A
400-20
EF
0.5KW
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
B
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-0
"
D
U
C
T
"
E
1
-3
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

IM-E-311
ENLARGED PWR PLAN AFTER - SECTOR 01
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-01
AFTER ALTERATIONS
POWER PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
62-0" 64-0" 64-0" 64-0" 64-0" 2-0"
624-0"
F G H J K L Fx
ES TEST RM
MIP
112
CALIBRATION
114
TOOL ROOM
115
CONF. RM
110
ARCHIVE
111
SHIPPING/ RECEIVING
102
MIP & CAL.
113
MAT. LAB
118
TOOL ROOM
116
TOOL AREA
117
301 A
1
HEAD SUB
CMM
CMM
CMM
C
M
M
C
M
M
C
M
M
SURFACE
PLATECMM
CMM
CMM
F
M
S
FMS
GAGE CAB GAGE CAB GAGE CAB GAGE CAB
CUBICLE
CUBICLE
CUBICLE
CUBICLE
FIRE CAB
T8000T8000
OPTIC
C
F
MCFM
Block
Lambda
Head
Lambda
Crank & Assy
Lambda
Plate Warming
600 Mahr PLM
Plate Surface
Instrument Storage
Plate Surface
Loader Torque
Engraver
Laser
Filter
Laser
Stand
Torque
Bench Electrical
Bench Pressure Inora Faro
pod Tri
Storage
Instrument Storage
Instrument Storage
Instrument Storage
Plate Surface
Cart
Cart
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Comp
Gage Block
Cabinet Shoe Case Book
CUBICLE
CUBICLE
Shower
Air
Copier
Cart
Cart
Cart
Cart
Cart
Cart
Files
Files
1/4 Ton
Hoist
1/4 Ton
Hoist
1/4 Ton
Hoist
1/4 Ton
Hoist
Zoller
Wheel Rack
UNISET - v
Movable Hoist
Turn M
ill Setting
UNISET - H
Washing M/C Power House
Movable Hoist
Tool Cabinet
Granite Table
Tool Cabinet
1 ton 1 ton
1 ton
1 ton 0.5 ton
0.7 ton
2 ton
0.5 ton
SVP3 G/D M/C
1 ton
Grinder
Zoller
1 ton
Zoller
1 ton
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
SD SD SD SD SD SD SD SD
10
9
8
7
A 404
1
RELOCATED SHUTTER
NEW MAN DOOR
1
0
0
/
1
0
0
6
0
/
6
0
F
VFD
1
0
0
/1
0
0
F
E
L
. 2
7
-
6
"
B
U
S
D
U
C
T
"
E
2
-
1
"
3
W
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
,
6
0
/4
0
F
6
0
/4
5
EXISTING
HVAC
R
F
-
7
.
5
H
P
S
F
-
1
5
H
P
VFD
HVAC
400-3
HVAC
400-6
HVAC
400-22
50
50 50
50
50
ACCU
400-3
57KW
HVAC
400-4
HVAC
400-19
HVAC
400-5
R
F
-5
H
P
S
F
-1
5
H
P
1
0
0
/1
0
0
1
0
0
/9
0
6
0
/4
0
3
0
/2
0
1
0
0
/1
0
0
DWH-400-5
TOILET AREA
F F F
F F F
TC90D
TC40D
TC90D
TC40D
TC40D TC90D TC90D
EXISTING
HVAC
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
IM-E-312
ENLARGED PWR PLAN AFTER - SECTOR 02
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-02
AFTER ALTERATIONS
POWER PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
SHOP
42-8"
UPS
140
ELEC. RM
141
Ax
ASSEMBLY
RELOCATION OF SUBSTATION
ELEC.RM
141
50
F
F
FF
EL. 27-6"
BUS DUCT "E2-1"
2500 AMPS 480V, 3PH, 3W
EXISTING
HVAC
TC90D
1
0
0
/1
0
0
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-1
A
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
B
U
S

E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
1
-3
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
PWR-MES-E-P1
PWR-ED-7/D-P1
PWR-ED-7/D-P2
PWR-ED-7/D-P3
E-LV-6 E-LV-5
E-LV-3
E-LV-2
E-LV-1
400-23
EF 3P 30A
3P 5KW
3P 5KW
400-22
EF
3P 30A
MV1 E2 E3 E6 BLA
PRO E5 E4 E1 E-
3P 5KW
400-21
EF
3P 30A
400-20
EF
0.5KW
6
0
/6
0
EL. 27-6"
BUS DUCT "E1-3"
2000 AMPS 480V, 3PH, 3W
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
B
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
6
0
/6
0
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
3
-1
"
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
2
0
0
/1
5
0
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-3
"
2
0
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-0
"
B
U
S
D
U
C
T
"
E
1
-3
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

IM-E-313
ENLARGED PWR PLAN AFTER - SECTOR 03
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-03
AFTER ALTERATIONS
POWER PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
CELL1
PURITY PARTS
STORAGE
OFFICE
CONF. RM
COOLANT(LOWER)
ENGING TEST
ES TEST RM
SUB-MATERIAL RM
SHOP
101
RAW MATERIAL AREA
120
MAINTENANCE OFFICE
DIS-ASSEMBLY
119
MACHINING AREA
121
CELL2
MAT. LAB
118
A 401
1
CRANK
HEAD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
A 404
1
F
F
VFD
F
50
HVAC
400-5
R
F
-5
H
P
S
F
-1
5
H
P
DWH-400-5
TOILET AREA
TC90D
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
EL. 27-6"
BUS DUCT "E2-1G"
400 AMPS 480V, 3PH, 3W
6
0
/6
0
EL. 27-6"
BUS DUCT "E3-1H"
400 AMPS 480V, 3PH, 3W
EL. 27-6"
BUS DUCT "E3-1J"
400 AMPS 480V, 3PH, 3W
1
0
0
/1
0
0
100/40
L
T
G
-E
-6
/J
F
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
2
-1
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
HVAC
400-6
HVAC
400-7
50
50
1
0
0
/1
0
0
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
G
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
W
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
,
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
TC90D
TC90D
IM-E-314
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-04
AFTER ALTERATIONS
POWER PLAN
ENLARGED
ENLARGED PWR PLAN AFTER - SECTOR 04
1 AS SHOWN 75 50 25
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
301 A
2
BREAK RM
130
LOCKER RM(W)
LOCKER RM(M)
REST RM(W)
REST RM(M)
SHOWER RM(M)
136
SHOWER RM(W)
135
131
IT RM
138
132
133
134
137
JANITOR RM
VESTIBULE
103
A 403
1
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
A B D E F C Fx
RELOCATED VESTIBULE
HVAC
F
F
F
F F
F
F
F
F
F
FFF
V
F
D
V
F
D
FFF
F
F
50
DO CP
400-1
400-10
HVAC
CUH
L
T
G
-E
-3
/F
1
0
0
/1
0
0
3
0
/2
0
6
0
/6
0
3
0
/2
0
1
0
0
1
0
0
/
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
A
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
3
-1
"
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
2
0
0
/1
5
0
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-3
"
2
0
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-0
"
B
U
S
D
U
C
T
"
E
1
-3
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-3
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
B
U
S

1
0
0
/1
0
0
E
L
. 2
6
-0
"
D
U
C
T
"
E
1
-1
A
"
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
, 4
W
B
U
S

1
0
0
/1
0
0
1
0
0
/1
0
0
1
0
0
/1
0
0
400-4
ACCU
95.6KW
400-1
400-18
400-11
HVAC
400-13
HVAC
400-12
HVAC
50
50
50
CAC
RF-10HP
SF-30HP
HVAC-400-18
RETURN FAN ON
MOUNT VFD FOR
T
C
1
5
0
D
TC90D
TC90D
TC90D
EXISTING
HVAC
EXISTING
HVAC
EXISTING
HVAC
TC90D
TC150D
TC90D
EXISTING
HVAC
IM-E-315
ENLARGED PWR PLAN AFTER - SECTOR 05
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-05
AFTER ALTERATIONS
POWER PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
COOLANT(LOWER)
120
MAINTENANCE OFFICE
122
MAINTENANCE PARTS AREA
REST RM(W)
124
REST RM(M)
125
123
MACHINING AREA
121
JANITOR RM
126
A 402
1
BLOCK
CRANK
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
F G H J K L Fx
RELOCATED VESTIBULE
50
HVAC
400-8
50
HVAC
400-8
50
F F
F
F
F
F
HVAC
400-8
FFF
HVAC
400-7
50
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
G
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
F
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
E
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
D
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
C
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
1
-1
C
"
4
W
4
0
0
A
M
P
S
4
8
0
/2
7
7
V
, 3
P
H
,
1
0
0
/1
0
0
1
0
0
1
0
0
/
3
0
/2
0
1
0
0
/1
0
0
6
0
/6
0
E
L
. 2
7
-6
"
B
U
S
D
U
C
T
"
E
3
-1
"
2
5
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
LP-E-K-4/20,22,24
400-4
DWH
EF
400-2
400-9
HVAC
50
L
T
G
-E
-3
/F
1
0
0
/1
0
0
1
0
0
1
0
0
/
E
L
. 2
6
-0
"
B
U
S
D
U
C
T
"
E
3
-1
B
"
4
0
0
A
M
P
S
4
8
0
V
, 3
P
H
, 3
W
TC90D
EXISTING
HVAC
EXISTING
HVAC
EXISTING
HVAC
TC90D
TC90D
TC90D
IM-E-316
ENLARGED PWR PLAN AFTER - SECTOR 06
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-06
AFTER ALTERATIONS
POWER PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
C
M
M
C
M
M
C
M
M
C M M C M MC M M
S U R F A C E
P L A T E
C M M C M M C M MF M S
F
M
S
GAGE CAB
GAGE CAB
GAGE CAB
GAGE CAB
C U B I C L E C U B I C L E
C U B I C L E C U B I C L E
FIRE CAB
T 8 0 0 0
T
8
000
O P T I C
C F M
C F M
B l o c k
L a m b d a
H e a d
L a m b d a
C r a n k & A s s y
L a m b d a
Plate
Warming
600
Mahr PLM
Plate
Surface
Instrument Storage
Plate
Surface
Loader
Torque
E n g r a v e r
L a s e r
F i l t e r
L a s e r
S t a n d
T o r q u e
Bench
Electrical
Bench
Pressure
Inora
Faro
podTri
S t o r a g e
Instrument Storage
I n s t r u m e n t S t o r a g e
Instrument Storage
Plate
Surface
Cart
Cart
F i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e s
F i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e s
C o m p
G a g e B l o c k
Cabinet
Shoe
Case
Book
C U B I C L E
C U B I C L E
Shower
Air
C
o
p
ie
r
Cart
Cart
Cart
Cart
Cart
Cart
F i l e sF i l e s
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
Zoller
W
h
e
e
l R
a
c
k
U
N
IS
E
T
- v
M
o
v
a
b
le
H
o
is
t
Turn Mill Setting
UNISET - H
W
a
s
h
in
g
M
/C
P
o
w
e
r H
o
u
s
e
M
o
v
a
b
le
H
o
is
t
Tool Cabinet
G
ra
n
ite
T
a
b
le
T
o
o
l C
a
b
in
e
t
1
to
n
1
to
n
1
to
n
1
to
n
0
.5
to
n
0
.7
to
n
2
to
n
0
.5
to
n
S
V
P
3
G
/D
M
/C
1
to
n
G
rin
d
e
r
R
E
L
O
C
A
T
E
D
1
T
O
N
H
O
IS
T
Zoller 1
to
n
Zoller 1
to
n
(B
Y
O
T
H
E
R
S
)
64-0"
6
4
-
0
"
64-0" 64-0"
1
0
K
L
9
C
O
N
F
. R
M
E
S
T
E
S
T
R
M
M
IP
1
1
2
C
A
L
IB
R
A
T
IO
N
1
1
4
T
O
O
L
R
O
O
M
1
1
5
D
IS
-
A
S
S
E
M
B
L
Y
1
1
9
C
O
N
F
. R
M
1
1
0
A
R
C
H
IV
E
1
1
1
M
IP
&
C
A
L
.
1
1
3
M
A
T
. L
A
B
1
1
8
T
O
O
L
R
O
O
M
1
1
6
T
O
O
L
R
O
O
M
1
1
7
8 7
19-6" 44-6" 31-1" 29-9" 3-2"
4-11" 22-5"
15-10" 46-11" 31-0" 35-0" 15-6" 25-3" 22-6" 22-5"
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN 1
_
16-3" 25-3" 22-6"
4-11"
1
1
8
PS PS
J T
J
J J J J
J J J
J
J
J
J J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J J
J
J
J J J
J J J
J
J
J
J
J
J
J
J
J J J J
J
J J
J
PWR-E-K/9-P6
4G/GFI 4G/GFI 4G/GFI 4G/GFI 4G/GFI
4G/GFI
4G/GFI 4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI 4G/GFI 4G/GFI 4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
4G/GFI
1P 208V
3P 208V
1P 208V
RCP-E-K/9-R1,R3,R5
RCP-E-K/9-R1,R3 RCP-E-K/9-R1
R1
R1 R3 R3 R5
R5
RCP-E-K/9-R2
R2
R2
R4
R4 R4
RCP-E-K/9-R2,R4
R6 R6
R6
RCP-E-K/9-R2,R4,R6
RCP-E-K/9-R7
R7
R7
R7
R9
R9
R9
RCP-E-K/9-R7,R9
RCP-E-K/9-R7,R9,R11 R11
R11
3P 480V
3P 480V
3P 480V
3P 480V
3P 480V
3P 480V
3P 480V
4G/GFI 4G/GFI 4G/GFI
4G/GFI
R8
R8
R8
RCP-E-K/9-R8
R10
R10
R10
RCP-E-K/9-R8,R10
R12
R12
R12
RCP-E-K/9-R8,R10,R12
R21
R21 R21
R13 R13
RCP-E-K/9-R13
R15 R15
RCP-E-K/9-R13,R15
RCP-E-K/9-R13,R15,R17
R17
R17
R17
RCP-E-K/9-R14
R14
R14
R14
R16
R16
R16
R18
RCP-E-K/9-R16
R18
R18
RCP-E-K/9-R14,16,18
RCP-E-K/9-R19
R19 R19 R19
RCP-E-K/9-R21
RCP-E-K/9-R23
AUTO SLIDING DOOR
RCP-E-K/9-R20,R22
R20,22
RCP-E-K/9-R25,R27,29
R25,R27,R29
LP-E-K/9-P07,09,11
PWR-E-K/9-P13
P13
PWR-E-K/9-P12
P12
PWR-E-K/9-P11
P11
PWR-E-K/9-P10
P8
PWR-E-K/9-P1
PWR-E-K/9-P3
PWR-E-K/9-P4
PWR-E-K/9-P5
PWR-E-K/9-P7
PWR-E-K/9-P8
PWR-E-K/9-P9
PWR-E-K/9-P2
LP-E-K/9-P08,10,12
LP-E-K/9-P13,15,17
LP-E-K/9-P14,16,18
LP-E-K/9-P19,21,23
LP-E-K/9-P20,22,22
LP-E-K/9-P25,27,29
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV VAV
-14
400
-36
400
-5
400
-19
400
-17
400
-18
400
-08
400
-04
400
-02
400
POWER DROPS OVER
BENCHES AND STORAGE CABINETS
MUST BE 50" FROM FLOOR.
LP-E-K/9(LIGHTING PANEL)
TR-E-K/9(REUSE EXISTING)
RCP-E-K/9(RECEPTACLE PANEL)
3P4W480/277V
3P 480-120/208 45KVA
3P 120/208V
PWD-E-K/9(MAIN PANEL)3P4W480/277V
PWR-E-K/9(FOR VAVS & MECH. EQUI.)3P4W480/277V
BUSDUCT"E2-1"
SEE DWG.NO.IM-E-302.
LP-E-K/10
3P4W480/277V
ENLARGED POWER PLAN- OFFICE AREA
1
IM-E-317
OFFICE AREA
POWER PLAN
ENLARGED
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
FOR UPS & HVAC SHUT-DOWN FOR
PROVIDE EPO STATION PER NEC-645
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
64-0" 64-0" 64-0"
4 3 2
R
A
W
M
A
T
E
R
IA
L
R
M
1
2
0 M
A
IN
T
E
N
A
N
C
E
O
F
F
IC
E
1
2
2
M
A
IN
T
E
N
A
N
C
E
P
A
R
T
S
R
O
O
M
1
2
3
M
A
C
H
IN
IN
G
A
R
E
A
1
2
1
5
6-6"
16-8" 35-0" 12-4" 57-0" 7-0"
44-1" 16-8" 19-11"
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN MAINTEANCE 1
_
T
J
J J
J
J
J
J J
R5
J
J
R5
3P 480V
R5
LP-E-K-4/7,9,11
R5
RCP-E-4/K-R5
DOOR
LP-E-K-4/8,10,12
RCP-E-4/K-R3
4G/GFI
4G/GFI
R3
LP-E-K-4/19,21,23
4G/GFI
R3
3P 208V 5.7KW
2P 30A
RCP-E-4/K-R7,9
3P 208V 5.7KW
2P 30A
RCP-E-4/K-R4,6
RCP-E-4/K-R2
RCP-E-4/K-R1
T.R 480-120/208V 3P 20KVA
4G/GFI
R1
4G/GFI
R1
HP
FCU
FCU
HP
EF
400-25
3P 1.5KW
3P 1.5KW
400-24
EF
LP-E-K-4/14,16,18
LP-E-K-4/13,15,17 DOOR
BUSDUCT"E1-1C"
SEE DWG.NO.IM-E-302.
LP-E-4/K
RCP-E-4/K
TR-E-4/K
3P4W480/277V
3P 480-120/208 20KVA
3P 120/208V
1
IM-E-318
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
SHOP AREA
POWER PLAN
ENLARGED
ENLARGED POWER PLAN- SHOP AREA
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
4
8
-
0
"
64-0" 64-0"
A
B
3 2 1
B
R
E
A
K
R
M
1
3
0
L
O
C
K
E
R
R
M
(W
)
L
O
C
K
E
R
R
M
(M
)
R
E
S
T
R
M
(M
)
S
H
O
W
R
M
(M
)
1
3
6
S
H
O
W
R
M
(W
)
1
3
5
1
3
1
IT
R
M
1
3
8
1
3
2
1
3
4
1
3
7
J
A
N
IT
O
R
R
M
R
E
S
T
R
M
(W
)
1
3
3
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN BREAK ROOM 1
_
22-0" 42-0" 10-2" 10-4" 29-10" 7-4" 6-4"
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J J
J
J
J
J J J
J J J J
J
J
MES-E-1/A
T
LP-E-1/A
TR-E-1/A
RCP-E-1/A
1P 3W120/240V
3P4W480/277V
3P 480-120/208 45KVA
3P 120/208V
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
MR1
MR3
MR5
MR1,3,5
MR7,9,11
MR7
MR9
MR11
MR2
MR4
MR6
MR2,4,6
MR8
MR10
MR12
MR6,8,12
R1
R3
R5
RCP-E-1/A-R1,R3,R5
RCP-E-1/A-R3,R5
RCP-E-1/A-R5
RCP-E-1/A-R11
R11
R9
R7
RCP-E-1/A-R9,R11
RCP-E-1/A-R7,R9,R11
R10
R8
RCP-E-1/A-R8,R10
R2
R2
R2
R4
R4
R4
RCP-E-1/A-R2,R4
R6
R6
R6 R6
RCP-E-1/A-R2,R4,R6
RCP-E-1/A-R12,R14
R12 R14
BUSDUCT"E1-1A"
SEE DWG.NO.IM-E-302.
BUSDUCT"E1-3C"
SEE DWG.NO.IM-E-302.
PWR-E-1/A(FOR VAVS & MECH. EQUI.)3P4W480/277V
VAV
400-20
VAV
400-6
VAV
400-21
CAV
400-3
CAC
400-1
VAV
400-15
VAV
400-1 VAV
400-9
VAV
400-11
PWR-E-1/A-P1
PWR-E-1/A-P3
LP-E-1/A/5
LP-E-1/A-2
LP-E-1/A-4
ACCU
400-4
(ON ROOF)
3/4"-3#6 & 1#10(G)
PWR-E-1/A-P2 PWR-E-1/A-P4
PWR-E-1/A-P6
EF
400-8
PWR-E-1/A-P7
DWH
400-2
3P 10.5KW
PWR-E-1/A-P5
BUSDUCT"E3-1"
SEE DWG.NO.IM-E-302.
3P 8.9KW
3P 15KW
3P 12.8KW
3P 7.4KW
1P 3.3KW
1P 2.3KW
3P 15KW
1P 1.5KW
3P 4KW
1
IM-E-319
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
BREAK AREA
POWER PLAN
ENLARGED
ENLARGED POWER PLAN- BREAK AREA
BY OWNER
SUPPLIED & INSTALLED
PANEL MES-E-01A IS
IT ROOM POWER SUPPLY
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
7
6
5
42-8"
UPS
140
ELEC. RM
141
Ax
A 404
1
J
J
J
J
SEE OVERALL PART PLAN
SEE DWG NO IM - E - 310
ELEC.RM
141
E1
E2
E4
E3
E5
E6
E-
MV1
PRO
BLA
E-LV-1
E-LV-2
E-LV-3
E-LV-5 E-LV-6
EF
400-23
EF
400-22
EF
400-21
EF
400-20
PWR-ED-7/D-P1
PWR-ED-7/D-P2
PWR-ED-7/D-P3
3P 5KW
3P 5KW
3P 5KW
3P 30A
3P 30A
3P 30A
RCP-E-7/C-16
0.5KW
SEE DWG. NO. IM - E - 310 POWER PLAN
SEE DWG. NO. IM - E - 310 POWER PLAN
SEE DWG. NO. IM - E - 310 POWER PLAN
1
IM-E-320
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
SUBSTATION
POWER PLAN
ENLARGED
ENLARGED POWER PLAN- SUBSTATION
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
BLOCK
CRANK
HEAD HEAD-SUB
ASSEMBLY
COOLANT
6
4
-
0
"
48-0" 64-0" 64-0 1/16" 64-0" 64-0" 62-0" 64-0" 64-0" 64-0" 64-0"
ELEC. ROOM
MEASURING RM
CALIBRATION RM
MATERIAL AREA
CELL3
CELL2
CELL1
OFFICE
CONF. RM
SUB-MATERIAL RM
BREAK RM OPEN OFFICE
2-0"
624-0"
5
7
6
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
SHIPPING/ RECEIVING
10
A B D E F G H J K L C
9
8
7
6
5
4
3
2
1
Fx
SHIPPING/ RECEIVING
PURITY PARTS
STORAGE
ENGINE TEST
TOOL RM
ES TEST RM
SPINDLE RM
TOOL RM
TOOL RM
1ST FLOOR PLAN BEFORE CHANGE 1
_ SCALE: 1/32" = 1-0"
ARCH D 050 FT 100 FT 150 FT 200 FT
RELOCATE 3 DOCK DOORs
MAKE THE WALL, MATCH EXIST. WALL
J J J J J J
J
(TYP)
SEE NOTE "1"
EMLTG-E-7/D-17
LTG-K-10/1,3,5
PS TR
LTG-K-10/2
FT
XA
(TYP)
RCP-K-10
LTG-K-10
(TYP)
SA
(TYP)
SF
PUSHBUTTON STATION PBS-1
SEE NOTES 6 & 7
J
XA
FT
XB
22
(TYP)
RCP-E-7/C-22
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
LTG-E-6/F
LTG-E-3/C
LTG-E-3/C-1
LTG-E-3/C-2
LTG-E-3/C-3
LTG-E-7/C-1
LTG-E-5/C-3
LTG-E-3/C-4
LTG-E-3/C-6
LTG-E-7/C-4
LTG-E-3/C-5
LTG-E-3/F-1
LTG-E-3/F-2
LTG-E-3/F-3
LTG-E-3/F-4
LTG-E-3/F-5
LTG-E-3/J-3
LTG-E-3/J-4
LTG-E-3/J-1
LTG-E-3/F-6
LTG-E-3/F-7
LTG-E-3/J-6
LTG-E-3/J-7
LTG-E-3/F-8 LTG-E-3/F-9
LTG-E-3/J-8
LTG-E-3/J-5
LTG-E-3/J-9
LTG-E-3/J-2
LTG-E-6/F-9
LTG-E-6/J-8
LTG-E-6/J-7
LTG-E-6/J-6
LTG-E-6/F-8
LTG-E-6/F-7
LTG-E-6/F-1
LTG-E-6/F-2
LTG-E-6/F-3
LTG-E-6/F-4
LTG-E-6/F-5
LTG-E-6/J-2
LTG-E-6/F-6
LTG-E-6/J-1
LTG-E-6/J-3
LTG-E-6/J-4
LTG-E-6/J-5
LTG-E-6/J-9
LTG-E-7/C
LTG-E-3/F
LTG-E-3/J
LTG-E-6/J
LTG-E-7/C-2
EMLTG-E-7/D-7
EMLTG-E-7/D-5
EMLTG-E-7/D-3
EMLTG-E-7/D-1
EMLTG-E-7/D-2
EMLTG-E-7/E-4
EMLTG-E-7/D-6
EMLTG-E-7/D-8
PBS-1
STATION
PUSHBUTTON
PUSHBUTTON STATION PBS-3
PUSHBUTTON STATION PBS-2
PUSHBUTTON STATION PBS-4
PUSHBUTTON STATION PBS-5
PUSHBUTTON STATION PBS-6
LTG-E-3/J-10
EMLTG-E-7/E-10
LTG-E-3/J-11
LTG-E-3/J-12
LTG-E-3/J-13
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
60/60
(TYP)
(TYP)
27
DO
DL
10/C 20,22,24
(TYP)
27
DO
DL 27
DO
DL 21212121 21
RCP-E-7/C-27
RCP-E-7/C-21
(TYP)
PER-MES-E
PE
LCP CANOPY
UNDER
MOUNTED ON ROOF
PHOTOCELL
J J J
(TYP)
J J
PE
LCP
ON ROOF
PHOTOCELL
CANOPY
UNDER
MOUNTED
J J J J J
10/C 21,23,25
10/C 13,15,19
SA
XA
XB
XA
SA
XA
SF SE
J
HA
J
J
J
J
J
22
22
SF XB
22
22
J
J
SA XA
J
FB
HA
XB
XB
HA
J
FB
HA
FB
HA
XB
SA
XA
FB
HC
FB
HA
CP CP CP
J J J J J J J J
LTG-E-7/C-10
(TYP)
HA (TYP)
HA
J
LTG-E-7/C-11
J
EMLTG-E-7/D-15
J
LTG-E-7/C-12
LTG-E-6/F-10
J J J J J J
RCP-K-10/1
UPS
BATTERY
LTG T.R
EPWD400
LTG-E-7/C-13
LTG-E-7/C-12
LTG-E-7/C-14
LTG-E-7/C-15
LTG-E-3/C-7
LTG-E-3/C-8
J
LTG-E-1/H
S 1 1 1
1 1
1 1 1
1
1
1 1
1
9
1
1
9
J
TO EMLTG-7/0-9
J
J
9
9
9
9
9
9
9
9
9
9
9
9
9 9 9 9 9
9
9
9
9
9
9 9 9 9 9
9 9
9
9
9
9
9
1
1
1
1 1
9
1
1
1
1 1
1
1
S
1 1 S3
S3
S S
3
1 1
1
1
1
S3
3
3
3
3 3
3
3 3
3
3 3
3
3 3
3 3
3
3
3
3 3
3
3
3
S
S
S
S
S
S
3
3 3 3
3
3
3 3
9
3
Sab S
3
3
3
3a
3a
3a
3a
3a
3a
3a
3a
3b
3b S
ab S
3a
3a
3a
3a
3a
3a
3a
3a
3b
3b
S S
ab
3b 3a 3a
S S S S S
S S S S S
J
5a
5a
5a
5a
5a
5a
5a
5a
5a
5a
5a
5a
5a
5a
5a
5b
5b
5b
5b
5b
5b
5b
5b
5b
5b
7c
7c
7c
7c
7c
7c
7c
7c
7c
7c
7d
7d
7d
7d
7d
7d
7d
7d
7d
7d
7d
7d
7d
7d
7d
7e
7e
7e
7e
7e
7e
7e
7e
7e
7e
7e
7e
7e
7e
S S S S S
7e
SS
2b
2b
2b
2b
2b
2b 2a
2a
2a
S
2
2
S
2 2
2
2 2
S 2
2
2
2 2 2
2 2 2 S
4
9 9
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
S
S
6 6 6
6 6 6
6 6 6
6 6 6
6 6 6
6 6 6
6 6 6
6 6 6
6
6
6
6
S
S
S
S
8
8
8 8
11
EMLTG-E-7/D-11
J
11
11
11
J
J
SSSS
S
S
S
S
S SSS
11 11
8
8
8 8
UNLESS OTHERWISE NOTED.
AREA IS FROM PANEL LTG-E-7/C
ALL 277 VOLT LIGHTING IN THIS
8 8 8
8 8 8
8 8 8
8 8 8
8 8 8
7b 7b 7b 7b 7b
7b 7b 7b 7b 7b
7b 7b 7b 7b 7b
7b 7b 7b 7b 7b
6a
6a
6a 6a 6a
6a 6a
6a
6a 6a
6a 6a 6a 6a 6a
6a 6a 6a 6a 6a
6a 6a 6a
6a 6a 6a
6b 6b 6b
6
6
6 6
6 6
9 9
9
9
9 9
9
9
S
S
9 9 13 9 9 9
9 9 9 9
9 9 9 9 S
S
S
9
9
13
13
7
7
7
7
13
7
7
7
7
7
7
7
7
7
7
7
7
7
13
7
7
7
7
7
7
S
J
em
ltg-e-7/d-13
SS
7
7 7 7 7 7
7 7 7 7 7
5a 5a 5a 5a 5a
5a 5a 5a 5a 5a
5b 5b 5b 5b 5b
SS
SS
J
SS 5 5 5
5 5 5
5 5 5
S 13
13
13
1 1 1 13 13
1
1
1
1
1
1
a/b
a/b
a/b
a/b
a/b
SS
S
S S
S 13a
1 1 1 1
1 1 1 1
J
SS
SS
3
13
13
13
13
3 3
3 3 3
3 3 3
3 3 3
3 3 3
S
3
AFTER DEMOLISH RELOCATION
AFTER DEMOLISH RELOCATION
AFTER DEMOLISH RELOCATION
AFTER DEMOLISH RELOCATION
AFTER DEMOLISH RELOCATION
1 01 IN = 32 FT 200 100
IM-E-401
ALTERATIONS
BEFORE
LIGHTING
OVERALL PLAN
OVERALL PLAN- LIGHTING BEFORE ALTERATIONS
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING AREAS THAT
CLOUDED ITEMS INDICATE
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4
-
0
"
48-0" 64-0" 64-0 1/16" 64-0" 64-0" 62-0" 64-0" 64-0" 64-0" 64-0" 2-0"
624-0"
5
7
6
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
10
A B D E F G H J K L C
9
8
7
6
5
4
3
2
1
Fx
301 A
2
CELL1
PURITY PARTS
STORAGE
OFFICE
CONF. RM
COOLANT(LOWER)
ENGING TEST
ES TEST RM
SUB-MATERIAL RM
MIP
112
SHOP
101
CALIBRATION
114
TOOL ROOM
115
BREAK RM
130
LOCKER RM(W)
LOCKER RM(M)
REST RM(W)
REST RM(M)
RAWMATERIAL AREA
120
MAINTENANCE OFFICE
122
MAINTENANCE PARTS AREA
REST RM(W)
124
REST RM(M)
125
123
DIS-ASSEMBLY
119
MACHINING AREA
121
CONF. RM
110
ARCHIVE
111
SHIPPING/ RECEIVING
102
SHOWER RM(M)
136
SHOWER RM(W)
135
131
IT RM
138
132
133
134
137
JANITOR RM
JANITOR RM
126
MIP & CAL.
113
VESTIBULE
103
CELL2
MAT. LAB
118
A 402
1
A 401
1
A 403
1
TOOL ROOM
116
TOOL AREA
117
OFFICE
301 A
1
42-8"
UPS
140
ELEC. RM
141
Ax
A 404
1
BLOCK
CRANK
HEAD
ASSEMBLY
HEAD SUB
CMM
CMM
CMM
CMM
CMM
CMM
SURFACE PLATECMM
CMM
CMM
FMS
FMS
GAGE CAB GAGE CAB GAGE CAB GAGE CAB
CUBICLE
CUBICLE
CUBICLE
CUBICLE
FIRE CAB
T8000T8000 OPTIC
CFMCFM
BlockLambda
HeadLambda
Crank & Assy
Lambda
Plate Warming
600 Mahr PLM
Plate Surface
Instrument Storage
Plate Surface
Loader Torque
EngraverLaser
FilterLaserStandTorque
Bench Electrical Bench Pressure Inora Faro pod Tri
Storage
Instrument Storage
Instrument Storage
Instrument Storage
Plate Surface
Cart
Cart
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
FilesCompGage Block
Cabinet Shoe Case Book
CUBICLE
CUBICLE
Shower Air
Copier
Cart
Cart
Cart
Cart
Cart
Cart
Files
Files
1/4 Ton Hoist
1/4 Ton Hoist
1/4 Ton Hoist
1/4 Ton Hoist
Zoller
Wheel Rack
UNISET - v
Movable Hoist
Turn Mill Setting
UNISET - H
Washing M/C Power House
Movable Hoist
Tool CabinetGranite Table
Tool Cabinet
1 ton 1 ton
1 ton
1 ton 0.5 ton 0.7 ton
2 ton
0.5 ton
SVP3 G/D M/C 1 ton
Grinder
Zoller
1 ton
Zoller
1 ton
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD SD SD
SD SD SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
SDSD SDSD SDSD SDSD
SD SD SD SD SD SD SD SD
SD SDSD SDSD SDSD SD
SD SD SD SD SD SD SD SD
10
9
8
7
6
5
4
3
2
1
A 404
1
A B D E F G H J K L C Fx
RELOCATED SHUTTER
NEWMAN DOOR
RELOCATED VESTIBULE
S 3
3 3
9
J J J J J J
(TYP)
SEE NOTE "1"
EMLTG-E-7/D-17
LTG-K-10/1,3,5
PS
HA
LTG-K-10
(TYP)
SA
(TYP)
SF
PUSHBUTTON STATION PBS-1
J
XA
FT
XB
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
LTG-E-6/F
LTG-E-3/C
LTG-E-3/J-2
LTG-E-7/C
LTG-E-3/F
LTG-E-3/J
LTG-E-6/J
EMLTG-E-7/D-7
EMLTG-E-7/D-5
EMLTG-E-7/D-3
EMLTG-E-7/D-1
EMLTG-E-7/D-2
EMLTG-E-7/E-4
EMLTG-E-7/D-6
EMLTG-E-7/D-8
PBS-1
STATION
PUSHBUTTON
PUSHBUTTON STATION PBS-3
PUSHBUTTON STATION PBS-2
PUSHBUTTON STATION PBS-4
PUSHBUTTON STATION PBS-5
PUSHBUTTON STATION PBS-6
EMLTG-E-7/E-10
LTG-E-3/J-13
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
EMLTG-E-7/D
PE LCP CANOPY
UNDER
MOUNTED ON ROOF
PHOTOCELL
J
SA
XA
XB
XA
SA
XA
SE
J
HA
J
XB
J
J
FB
HA
XB
XB
HA
J
HA
HA
XB
SA
XA
FB
FB
HA
(TYP)
HA
J
J
EMLTG-E-7/D-15
J
J J J J J J
RCP-E-K/9-24
J
J
9 9
9
9
9 9
9
9
S
S
S
S
S
9
9
13
13
7
7
7
7
13
7
7
7
7
7
7
7
7
7
7
7
7
7
13
7
7
7
7
7
7
S
J
EMLTG-E-7/D-13
SS
7
7 7 7 7 7
7 7 7 7 7
5a 5a 5a 5a 5a
5a 5a 5a 5a 5a
5b 5b 5b 5b 5b
SS
SS
J
SS 5 5 5
5 5 5
5 5 5
S 13 13
1 1 1 13 13
1
1
1
1
1
1
a/b
a/b
a/b
a/b
a/b
SS
S
S S
S 13a
1 1 1 1
1 1 1 1
J
SS
SS
13
13
13
13
3 3 3
3 3 3
3 3 3
S
J
J
LIGHTING TYPE "FT" IN THE "HA" CHANGE
THE ELECTRICAL CHANGE IN THE ARCHITECTURAL CHANGES.
EXISTING SUBSTATION
NEWSUBSTATION
HATCH RE-USE EXISTING.
AHTCH RE-USE EXISTING.
3b
3a 3a
13
3b
CHANGE EXISTING AND NEWLIGHTING FIXTURES
NO CHANGE
SS
SSSS
1a
1b
1a
1b
1a
1b 1b
1a 13
1a 1a 1a 1a
1b 1b 1b 1b
13
13
1c 1c 1c 1c
1d 1d 1d 1d
SSS
1b 1a 1c
1b
1b 1a 1c
13 13
1b 1b
XA
LTG-K-9
3b
SSS
3c
3a
3a 3b 3c
3b 3c 3a
3b 3c 3a
3b 3c 3a
S S S
J
3a
3b
3c
3b
3a
3c
3b
3a
3c
3b
3a
3c
3b
3a
3c
3b
3a
8
8
8 8
8 8
3c 3c
3b
3a
8
8 8
8
8 8
8 8
8
8 8
LTG-K-9/1
LTG-K-9/1,3
S5a 5b
S S
5a
5b
5b
5b
5c 5c 5c
5c 5c 5c
S S
5b 5b 5b 5b
5a 5a 5a
5a
2a 2b 2c 2d
SSSS2a
2a
2a
2a
LTG-K-9/2
2b
2b
2b
2c
2c
2c
2c
2c
2d
2d
2d
2b 2d
2d 2b
S S
2a 2a 2a 2a
2b 2b 2b 2b
XA
PS
9 9
9
9S13
13 3b
3a 3a
13
3b
NO CHANGE
SS
SSSS
1a
1b
1a
1b
1a
1b 1b
1a 13
1a 1a 1a 1a
1b 1b 1b 1b
13
13
1c 1c 1c 1c
1d 1d 1d 1d
SSS
1b 1a 1c
1b
1b 1a 1c
13 13
1b 1b
XA
LTG-K-9
3b
SSS
3c
3a
3a 3b 3c
3b 3c 3a
3b 3c 3a
3b 3c 3a
S S S
J
3a
3b
3c
3b
3a
3c
3b
3a
3c
3b
3a
3c
3b
3a
3c
3b
3a
8
8
8 8
8 8
3c 3c
3b
3a
8
8 8
8
8 8
8 8
8
8 8
LTG-K-9/1
LTG-K-9/1,3
5a 5b
5a
5b
5b
5b
5c 5c 5c
5c 5c 5c
S S
5b 5b 5b 5b
5a 5a 5a
5a
2a 2b 2c 2d
SSSS2a
2a
2a
2a
LTG-K-9/2
2b
2b
2b
2c
2c
2c
2c
2c
2d
2d
2d
2b 2d
2d 2b
S S
2a 2a 2a 2a
2b 2b 2b 2b
XA
J
AFTER DEMOLISHED JOINT BOX CONNECTED LIGHTING FIXTURES INSTALLED
CHANGE EXISTING AND NEWLIGHTING FIXTURES
RE-USED EXISTING
RE-USED EXISTING
RE-USED EXISTING
LP-E-K/4
J
J
J
SS SS
SSSS
1d
1c
1b
1a
1b
1d
1c
1a
1b
1d
1c
1a
1b
1d
1c
1a
1b
1d
1c
1a
1b
1d
10
1a
10
10 10
1c
LP-E-K/4-3
3a
3a
3b
3a 3a
3a 3a
3b 3b
3b 3b
J
2
2
J
10
10
SS
S
5a
5b 5b
5c
9
2 2
2
S
S
D2
2 2
2
2S
J
2
2
2
D2
NEWTOILET
SEE ENLARGED PART PLAN
SEE DWG NO IM - E - 409
SEE ENLARGED PART PLAN
SEE DWG NO IM - E - 410
LP-E-A/1
S 3
S
3
S
3 S 3
S
S
S S S S
1a 1a 1a 1a 1a
1b 1b 1b 1b 1b 1b
1c 1c 1c 1c 1c 1c
1d 1d 1d 1d 1d 1d
S
S
PG-E-K/1-1
LP-E-K/1-1,3
LP-E-K/1-5
3 3 3 3 3
3
3
3
3
3 3 3 3 3
3 5 5 5 5
3 3 3
3
3 3
3 3
3
TO EMLTG-7/0-9
9
9
J
9
9
J
9
9
9
9
9
9 9
9
9
9
3
3
3
SEE ENLARGED PART PLAN
SEE DWG NO IM - E - 411
CHANGE EXISTING AND NEWLIGHTING FIXTURES
ENTRY CHANGE RELOCATION
LTG-E-3/C-5
EMLTG-E-7/D-2
LTG-E-3/C-5
LTG-E-3/J-1
EMLTG-E-7/D-2
(TYP)
XB
J
LTG-E-1/H
J
LTG-E-3/F-6
JJ
AFTER THE RELOCATION
OF EXISTING LIGHTING TEARDOWN
EL
EL
RL RL
NL NL NL NL NL NL NL NL NL NL
(TYP)
HA
NWC
NWC NWC NWC NWC NWC NWC
NWC
NWC NWC NWC
NWC
EL EL EL EL EL EL EL EL EL EL
S
SSSS
XA
SA
EMLTG-E-7/D-15
J
EMLTG-E-7/D-12
COOLANT BASEMENT FLOOR
EMERGENCY LIGHTING CONNECTION
SEE COOLANT SUBSTRUCTURE LIGHTING PLAN
SEE DWG. NO IM-E-412
SEE ENLARGED PART PLAN
SEE DWG NO IM - E - 413
RELOCATE 3 DOCK DOORs
MAKE THE WALL, MATCH EXIST. WALL
22
(TYP)
RCP-E-7/C-22
(TYP)
(TYP)
(TYP)
LTG-E-6/F
LTG-E-3/C
LTG-E-3/C-1
LTG-E-3/C-2
LTG-E-3/C-3
LTG-E-7/C-1
LTG-E-5/C-3
LTG-E-3/C-4
LTG-E-3/C-6
LTG-E-7/C-4
LTG-E-3/F-1
LTG-E-3/F-2
LTG-E-3/F-3
LTG-E-3/F-4
LTG-E-3/F-5
LTG-E-3/J-3
LTG-E-3/J-4
LTG-E-3/J-1
LTG-E-3/F-7
LTG-E-3/J-6
LTG-E-3/J-7
LTG-E-3/F-8 LTG-E-3/F-9
LTG-E-3/J-8
LTG-E-3/J-5
LTG-E-3/J-9
LTG-E-3/J-2
LTG-E-6/F-9
LTG-E-6/J-8
LTG-E-6/J-7
LTG-E-6/J-6
LTG-E-6/F-8
LTG-E-6/F-7
LTG-E-6/F-1
LTG-E-6/F-2
LTG-E-6/F-3
LTG-E-6/F-4
LTG-E-6/F-5
LTG-E-6/J-2
LTG-E-6/F-6
LTG-E-6/J-1
LTG-E-6/J-3
LTG-E-6/J-4
LTG-E-6/J-5
LTG-E-7/C
LTG-E-3/F
LTG-E-3/J
LTG-E-6/J
LTG-E-7/C-2
PBS-1
STATION
PUSHBUTTON
PUSHBUTTON STATION PBS-3
PUSHBUTTON STATION PBS-2
PUSHBUTTON STATION PBS-4
PUSHBUTTON STATION PBS-5
PUSHBUTTON STATION PBS-6
LTG-E-3/J-13
(TYP)
(TYP)
(TYP)
60/60
27
DO
DL
10/C 20,22,24
(TYP)
27
DO
DL 27
DO
DL 21212121 21
RCP-E-7/C-27
RCP-E-7/C-21
J J
(TYP)
J J
PE
LCP
ON ROOF
PHOTOCELL
CANOPY
UNDER
MOUNTED
J J J J J
10/C 21,23,25
10/C 13,15,19
SF
HA
J
J
J
J
22
22
SF
22
22
J
FB
HA
HA
FB
HA
FB
HA
FB
HA
CP CP CP
J J J J J J J J
LTG-E-7/C-10
(TYP)
HA
LTG-E-7/C-11
LTG-E-7/C-12
LTG-E-6/F-10
LTG-E-7/C-13
LTG-E-7/C-12
LTG-E-7/C-14
LTG-E-7/C-15
LTG-E-3/C-7
LTG-E-3/C-8
IM-E-404
ENLARGED 1STN FLOOR
(ALTERATION AFTER)
LIGHTING PLAN-2
IM-E-404
ENLARGED 1STN FLOOR
(ALTERATION AFTER)
LIGHTING PLAN-2
LP-E-K/4-1
LP-E-K/4-5
DRAWING ELECTRICAL NOTES
1 01 IN = 32 FT 200 100
IM-E-402
CHANGES
AFTER
LIGHTING
OVERALL PLAN
OVERALL PLAN- LIGHTING AFTER CHANGES
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING AREAS THAT
CLOUDED ITEMS INDICATE
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4

-
0
"
48-0" 64-0"
64-0 1/16"
64-0" 64-0" 62-0" 2-0"
624-0"
6
4

-
0
"
A B D E F C Fx
SHIPPING/ RECEIVING
102
OFFICE
42-8"
UPS
140
Ax
SD SD SD SD SD SD SD SD SD SD SD SD
RELOCATED SHUTTER
NEW MAN DOOR
(TYP)
(TYP)
L
T
G
-
E
-
7
/
C
E
M
L
T
G
-
E
-
7
/
D
-
3
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
2
(
T
Y
P
)
(TYP)
(TYP)
EMLTG-E-7/D
SA
XA
SA
XA
J
XB
(TYP)
HA
J
J
E
M
L
T
G
-
E
-
7
/
D
-
1
5
J
EXISTING SUBSTATION
S
XA
SA
EMLTG-E-7/D-15
RELOCATE 3 DOCK DOORs
MAKE THE WALL, MATCH EXIST. WALL
L
T
G
-
E
-
7
/
C
-
1
L
T
G
-
E
-
5
/
C
-
3
L
T
G
-
E
-
6
/
F
-
1
L
T
G
-
E
-
6
/
F
-
2
L
T
G
-
E
-
7
/
C
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
2
2
7
DO
DL
1
0
/
C

2
0
,
2
2
,
2
4
(TYP)
2
7
DO
DL 2
7
DO
DL 2
1
2
1
2
1
2
1
2
1
R
C
P
-
E
-
7
/
C
-
2
7
R
C
P
-
E
-
7
/
C
-
2
1
J J
(TYP)
J
PE
L
C
P
O
N

R
O
O
F
P
H
O
T
O
C
E
L
L
CANOPY
UNDER
MOUNTED
J J J J J
1
0
/
C

2
1
,
2
3
,
2
5
1
0
/
C

1
3
,
1
5
,
1
9
SF
FB
FB
CP CP CP
J J J J J J J J
L
T
G
-
E
-
7
/
C
-
1
0
(TYP)
HA
L
T
G
-
E
-
7
/
C
-
1
1
L
T
G
-
E
-
7
/
C
-
1
2
L
T
G
-
E
-
6
/
F
-
1
0
L
T
G
-
E
-
7
/
C
-
1
2
L
T
G
-
E
-
7
/
C
-
1
4
LTG-E-7/C-15
IM-E-404
ENLARGED 1STN FLOOR
(ALTERATION AFTER)
LIGHTING PLAN-2
IM-E-404
ENLARGED 1STN FLOOR
(ALTERATION AFTER)
LIGHTING PLAN-2
IM-E-403
ENLARGED LTG PLAN AFTER - SECTOR 01
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-01
AFTER ALTERATIONS
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
62-0" 64-0" 64-0" 64-0" 64-0" 2-0"
624-0"
F G H J K L Fx
ES TEST RM
MIP
112
CALIBRATION
114
TOOL ROOM
115
CONF. RM
110
ARCHIVE
111
SHIPPING/ RECEIVING
102
MIP & CAL.
113
MAT. LAB
118
TOOL ROOM
116
TOOL AREA
117
301 A
1
HEAD SUB
CMM
CMM
CMM
C
M
M
C
M
M
C
M
M
SURFACE
PLATECMM
CMM
CMM
F
M
S
FMS
GAGE CAB GAGE CAB GAGE CAB GAGE CAB
CUBICLE
CUBICLE
CUBICLE
CUBICLE
FIRE CAB
T8000T8000
OPTIC
C
F
MCFM
Block
Lambda
Head
Lambda
Crank & Assy
Lambda
Plate Warming
600 Mahr PLM
Plate Surface
Instrument Storage
Plate Surface
Loader Torque
Engraver
Laser
Filter
Laser
Stand
Torque
Bench Electrical
Bench Pressure Inora Faro
pod Tri
Storage
Instrument Storage
Instrument Storage
Instrument Storage
Plate Surface
Cart
Cart
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Comp
Gage Block
Cabinet Shoe Case Book
CUBICLE
CUBICLE
Shower
Air
Copier
Cart
Cart
Cart
Cart
Cart
Cart
Files
Files
1/4 Ton
Hoist
1/4 Ton
Hoist
1/4 Ton
Hoist
1/4 Ton
Hoist
Zoller
Wheel Rack
UNISET - v
Movable Hoist
Turn M
ill Setting
UNISET - H
Washing M/C Power House
Movable Hoist
Tool Cabinet
Granite Table
Tool Cabinet
1 ton 1 ton
1 ton
1 ton 0.5 ton
0.7 ton
2 ton
0.5 ton
SVP3 G/D M/C
1 ton
Grinder
Zoller
1 ton
Zoller
1 ton
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
SD SD SD SD SD SD SD SD
10
9
8
7
A 404
1
RELOCATED SHUTTER
NEW MAN DOOR
J J J J J J
(TYP)
SEE NOTE "1"
EMLTG-E-7/D-17
LTG-K-10/1,3,5
P
S
HA
LTG-K-10
(TYP)
SA
(TYP)
SF
PUSHBUTTON STATION PBS-1
J
XA
FT
XB
(TYP)
E
M
L
T
G
-
E
-
7
/
D
-
8
(TYP)
(TYP)
PE
LCP CANOPY
UNDER
MOUNTED
ON ROOF
PHOTOCELL
J
XB
XA
SE
J J J J J J
RCP-E-K/9-24
9 9
9
9
9 9
9
9
S
S
S
S
S
9
9
13
13
7
7
7
7
13
7
7
7
7
7
7
7
7
7
7
7
7
7
13
7
7
7
7
7
7
S
J
E
M
L
T
G
-
E
-
7
/
D
-
1
3
SS
7
7 7 7 7 7
7 7 7 7 7
5a 5a 5a 5a 5a
S
S
S
S
J
LIGHTING TYPE "FT" IN THE "HA" CHANGE
THE ELECTRICAL CHANGE IN THE ARCHITECTURAL CHANGES.
NO CHANGE
SS
S
S
S
S
1a
1b
1a
1b
1a
1b 1b
1a 13
1a 1a 1a 1a
1b 1b 1b
1b
13
13
1c 1c 1c 1c
1d 1d 1d 1d
S
S
S
1b 1a 1c
1b
1b 1a 1c
13 13
1b 1b
XA
LTG-K-9
3b
S
S
S
3c
3a
3a 3b 3c
3b 3c 3a
3b 3c 3a
3b 3c 3a
S S S
J
3a
3b
3c
3b
3a
3c
3b
3a
3c
3b
3a
3c
3b
3a
3c
3b
3a
8
8
8 8
8 8
3c
3c
3b
3a
8
8
8
8
8 8
8 8
8
8 8
LTG-K-9/1
LTG-K-9/1,3
S
5a 5b
S
S
5a
5b
5b
5b
5c 5c
5c
5c 5c 5c
S
S
5b 5b 5b 5b
5a
5a 5a
5a
2a 2b 2c 2d
S
S
S
S2a
2a
2a
2a
LTG-K-9/2
2b
2b
2b
2c
2c
2c
2c
2c
2d
2d
2d
2b
2d
2d 2b
S S
2a 2a 2a
2a
2b 2b 2b 2b
XA
P
S
9 9
9
9
S
13
NO CHANGE
SS
S
S
S
S
1a
1b
1a
1b
1a
1b 1b
1a 13
1a 1a 1a 1a
1b 1b 1b
1b
13
13
1c 1c 1c 1c
1d 1d 1d 1d
S
S
S
1b 1a 1c
1b
1b 1a 1c
13 13
1b 1b
XA
LTG-K-9
3b
S
S
S
3c
3a
3a 3b 3c
3b 3c 3a
3b 3c 3a
3b 3c 3a
S S S
J
3a
3b
3c
3b
3a
3c
3b
3a
3c
3b
3a
3c
3b
3a
3c
3b
3a
8
8
8 8
8 8
3c
3c
3b
3a
8
8
8
8
8 8
8 8
8
8 8
LTG-K-9/1
LTG-K-9/1,3
5a 5b
5a
5b
5b
5b
5c 5c
5c
5c 5c 5c
S
S
5b 5b 5b 5b
5a
5a 5a
5a
2a 2b 2c 2d
S
S
S
S2a
2a
2a
2a
LTG-K-9/2
2b
2b
2b
2c
2c
2c
2c
2c
2d
2d
2d
2b
2d
2d 2b
S S
2a 2a 2a
2a
2b 2b 2b 2b
SEE ENLARGED PART PLAN
SEE DWG NO IM - E - 409
L
T
G
-
E
-
6
/
F
-
3
L
T
G
-
E
-
6
/
F
-
4
L
T
G
-
E
-
6
/
F
-
5
L
T
G
-
E
-
6
/
J
-
2
L
T
G
-
E
-
6
/
F
-
6
L
T
G
-
E
-
6
/
J
-
1
L
T
G
-
E
-
6
/
J
-
4
L
T
G
-
E
-
6
/
J
-
5
J
FB
IM-E-404
ENLARGED LTG PLAN AFTER - SECTOR 02
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-02
AFTER ALTERATIONS
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
SHOP
42-8"
UPS
140
ELEC. RM
141
Ax
ASSEMBLY
(
T
Y
P
)
L
T
G
-
E
-
6
/
F
L
T
G
-
E
-
7
/
C
E
M
L
T
G
-
E
-
7
/
D
-
7
E
M
L
T
G
-
E
-
7
/
D
-
5
E
M
L
T
G
-
E
-
7
/
D
-
3
EMLTG-E-7/D-1
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
2
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
4
(
T
Y
P
)
(
T
Y
P
)
(
T
Y
P
)
EMLTG-E-7/D
HA
J
XB
J
HA
HA
J
NEWSUBSTATION
XA
S
S
S
S
S
XA
SA
EMLTG-E-7/D-15
22
(
T
Y
P
)
R
C
P
-
E
-
7
/
C
-
2
2
(
T
Y
P
)
L
T
G
-
E
-
6
/
F
L
T
G
-
E
-
3
/
C
-
2
L
T
G
-
E
-
7
/
C
-
1
L
T
G
-
E
-
7
/
C
-
4
L
T
G
-
E
-
6
/
F
-
1
L
T
G
-
E
-
6
/
F
-
2
L
T
G
-
E
-
7
/
C
L
T
G
-
E
-
7
/
C
-
2
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
2
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
4
(
T
Y
P
)
(
T
Y
P
)
HA
J
J
J
J
22
22
SF
22
22
J
HA
HA
L
T
G
-
E
-
7
/
C
-
1
3
L
T
G
-
E
-
7
/
C
-
1
2
L
T
G
-
E
-
7
/
C
-
1
4
LTG-E-7/C-15
IM-E-405
ENLARGED LTG PLAN AFTER - SECTOR 03
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-03
AFTER ALTERATIONS
LIGHITNG PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
CELL1
PURITY PARTS
STORAGE
OFFICE
CONF. RM
COOLANT(LOWER)
ENGING TEST
ES TEST RM
SUB-MATERIAL RM
SHOP
101
RAW MATERIAL AREA
120
MAINTENANCE OFFICE
DIS-ASSEMBLY
119
MACHINING AREA
121
CELL2
MAT. LAB
118
A 401
1
CRANK
HEAD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
A 404
1
(
T
Y
P
)
(
T
Y
P
)
L
T
G
-
E
-
6
/
F
L
T
G
-
E
-
6
/
J
E
M
L
T
G
-
E
-
7
/
E
-
4
E
M
L
T
G
-
E
-
7
/
D
-
6
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
4
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
6
L
T
G
-
E
-
3
/
J
-
1
3
(
T
Y
P
)
(
T
Y
P
)
HA
HA
XB FB
HA
9 9
9
9
S
S
S
S
9
9
13
7
7
7
13
7
7
7
7
7
7
7
7
7
7
13
7
7
7
7
7
S
J
E
M
L
T
G
-
E
-
7
/
D
-
1
3
SS
7
7 7 7 7 7
7 7 7 7 7
5a 5a 5a 5a 5a
5a 5a 5a 5a 5a
5b 5b 5b 5b 5b
S
S
S
S
J
S
S
5 5 5
5 5 5
5 5 5
S 13
13
1
1
1
13
13
1
1
1
1
1
1
a/b
a/b
a/b
a/b
a/b
SS
S
S S
S
13a
1 1 1 1
1 1 1 1
J
S
S
S
S
13
13
13
13
3 3 3
3 3 3
3 3 3
S
HATCH RE-USE EXISTING.
3b
3a
3a
13
3b
CHANGE EXISTING AND NEWLIGHTING FIXTURES
13 3b
3a
3a
13
3b
CHANGE EXISTING AND NEWLIGHTING FIXTURES
RE-USED EXISTING
RE-USED EXISTING
LP-E-K/4
J
J
J
S
S
S
S
1d
1c
1d
1c
1d
1c
1d
1c
1d
1c
1d
10
1c
LP-E-K/4-3
3a
3a
3b
3a
3a
3a 3a
3b 3b
3b 3b
J
EMLTG-E-7/D-12
COOLANT BASEMENT FLOOR
EMERGENCY LIGHTING CONNECTION
(
T
Y
P
)
(
T
Y
P
)
L
T
G
-
E
-
6
/
F
L
T
G
-
E
-
3
/
F
-
7
L
T
G
-
E
-
3
/
J
-
6
L
T
G
-
E
-
3
/
J
-
7
L
T
G
-
E
-
3
/
F
-
8
L
T
G
-
E
-
3
/
F
-
9
L
T
G
-
E
-
3
/
J
-
8
L
T
G
-
E
-
3
/
J
-
9
L
T
G
-
E
-
6
/
F
-
9
L
T
G
-
E
-
6
/
J
-
8
L
T
G
-
E
-
6
/
J
-
7
L
T
G
-
E
-
6
/
J
-
6
L
T
G
-
E
-
6
/
F
-
8
L
T
G
-
E
-
6
/
F
-
7
L
T
G
-
E
-
6
/
F
-
3
L
T
G
-
E
-
6
/
F
-
4
L
T
G
-
E
-
6
/
F
-
5
L
T
G
-
E
-
6
/
J
-
2
L
T
G
-
E
-
6
/
J
-
3
L
T
G
-
E
-
6
/
J
-
4
L
T
G
-
E
-
6
/
J
-
5
L
T
G
-
E
-
6
/
J
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
4
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
6
L
T
G
-
E
-
3
/
J
-
1
3
HA
HA
FB
HA
LP-E-K/4-1
IM-E-406
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
ENLARGED LTG PLAN AFTER - SECTOR 04
1 AS SHOWN 75 50 25
SECTOR-04
AFTER ALTERATIONS
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
301 A
2
BREAK RM
130
LOCKER RM(W)
LOCKER RM(M)
REST RM(W)
REST RM(M)
SHOWER RM(M)
136
SHOWER RM(W)
135
131
IT RM
138
132
133
134
137
JANITOR RM
VESTIBULE
103
A 403
1
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
A B D E F C Fx
RELOCATED VESTIBULE
S
3
3
3
9
(
T
Y
P
)
L
T
G
-
E
-
3
/
C
L
T
G
-
E
-
3
/
F
P
B
S
-
1
S
T
A
T
IO
N

P
U
S
H
B
U
T
T
O
N

P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
3
(
T
Y
P
)
(
T
Y
P
)
(
T
Y
P
)
(
T
Y
P
)
XB
J
J
FB
HA
XB
HA
J
LP-E-A/1
S 3
S
3
S
3
S 3
S
S
S S S S
1a 1a
1a
1a 1a
1b 1b 1b 1b 1b 1b
1c 1c 1c 1c 1c 1c
1d 1d 1d 1d
1d
1d
S
S
PG-E-K/1-1
LP-E-K/1-1,3
LP-E-K/1-5
3 3
3
3 3
3
3
3
3
3 3 3 3 3
3
5 5 5
5
3 3
3
3
3 3
3 3
3
T
O

E
M
L
T
G
-
7
/
0
-
9
9
9
J
9
9
J
9
9
9
9
9
9 9
9
9
9
3
3
3
SEE ENLARGED PART PLAN
SEE DWG NO IM - E - 411
CHANGE EXISTING AND NEWLIGHTING FIXTURES
ENTRY CHANGE RELOCATION
L
T
G
-
E
-
3
/
C
-
5
L
T
G
-
E
-
3
/
C
-
5
(
T
Y
P
)
XB
NL NL NL NL
NWC NWC NWC NWC
NWC
EL EL EL EL EL
(
T
Y
P
)
R
C
P
-
E
-
7
/
C
-
2
2
(
T
Y
P
)
L
T
G
-
E
-
3
/
C
L
T
G
-
E
-
3
/
C
-
1
L
T
G
-
E
-
3
/
C
-
2
L
T
G
-
E
-
3
/
C
-
3
L
T
G
-
E
-
3
/
C
-
4
L
T
G
-
E
-
3
/
C
-
6
L
T
G
-
E
-
3
/
F
-
1
L
T
G
-
E
-
3
/
F
-
2
L
T
G
-
E
-
3
/
F
-
3
L
T
G
-
E
-
3
/
F
P
B
S
-
1
S
T
A
T
IO
N

P
U
S
H
B
U
T
T
O
N

P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
3
(
T
Y
P
)
(
T
Y
P
)
6
0
/
6
0
J
J
J
22
22
SF
22
22
J
FB
HA
HA
L
T
G
-
E
-
3
/
C
-
7
L
T
G
-
E
-
3
/
C
-
8
IM-E-407
ENLARGED LTG PLAN AFTER - SECTOR 05
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-05
AFTER ALTERATIONS
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
COOLANT(LOWER)
120
MAINTENANCE OFFICE
122
MAINTENANCE PARTS AREA
REST RM(W)
124
REST RM(M)
125
123
MACHINING AREA
121
JANITOR RM
126
A 402
1
BLOCK
CRANK
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
F G H J K L Fx
RELOCATED VESTIBULE
(
T
Y
P
)
(
T
Y
P
)
(
T
Y
P
)
LTG-E-3/J-2
L
T
G
-
E
-
3
/
F
L
T
G
-
E
-
3
/
J
E
M
L
T
G
-
E
-
7
/
D
-
2
E
M
L
T
G
-
E
-
7
/
E
-
4
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
3
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
5
E
M
L
T
G
-
E
-
7
/
E
-
1
0
(
T
Y
P
)
HA
XB
SA
XA
FB
FB
J
J
J
AHTCH RE-USE EXISTING.
J
AFTER DEMOLISHED JOINT BOX CONNECTED LIGHTING FIXTURES INSTALLED
CHANGE EXISTING AND NEWLIGHTING FIXTURES
RE-USED EXISTING
RE-USED EXISTING
LP-E-K/4
J
J
S
S
S
S
S
S
S
S
1d
1c
1b
1a
1b
1d
1c
1a
1b
1d
1c
1a
1b
1d
1c
1a
1b
1d
1c
1a
1b
1d
10
1a
10
10 10
1c
LP-E-K/4-3
3a
3a 3a
3a
3a 3a
3b 3b
J
2
2
J
10
10
S
S
S
5a
5b
5b
5c
9
2 2
2
S
S
D2
2 2
2
2S
J
2
2
2
D2
NEWTOILET
SEE ENLARGED PART PLAN
SEE DWG NO IM - E - 410
ENTRY CHANGE RELOCATION
E
M
L
T
G
-
E
-
7
/
D
-
2
L
T
G
-
E
-
3
/
J
-
1
E
M
L
T
G
-
E
-
7
/
D
-
2
J
LTG-E-1/H
J
L
T
G
-
E
-
3
/
F
-
6
JJ
AFTER THE RELOCATION
OF EXISTING LIGHTING TEARDOWN
EL
EL
RL RL
NL NL NL NL NL NL NL
(
T
Y
P
)
HA
NWC
NWC NWC NWC NWC NWC NWC
NWC
EL EL EL EL EL EL
SEE COOLANT SUBSTRUCTURE LIGHTING PLAN
SEE DWG. NO IM-E-412
(
T
Y
P
)
L
T
G
-
E
-
3
/
F
-
2
L
T
G
-
E
-
3
/
F
-
3
L
T
G
-
E
-
3
/
F
-
4
L
T
G
-
E
-
3
/
F
-
5
L
T
G
-
E
-
3
/
J
-
3
L
T
G
-
E
-
3
/
J
-
4
L
T
G
-
E
-
3
/
J
-
1
L
T
G
-
E
-
3
/
F
-
7
L
T
G
-
E
-
3
/
J
-
6
L
T
G
-
E
-
3
/
J
-
7
L
T
G
-
E
-
3
/
F
-
8
L
T
G
-
E
-
3
/
F
-
9
L
T
G
-
E
-
3
/
J
-
8
L
T
G
-
E
-
3
/
J
-
5
L
T
G
-
E
-
3
/
J
-
9
LTG-E-3/J-2
L
T
G
-
E
-
3
/
F
L
T
G
-
E
-
3
/
J
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
3
P
U
S
H
B
U
T
T
O
N

S
T
A
T
IO
N

P
B
S
-
5
HA
FB
LP-E-K/4-1
LP-E-K/4-5
IM-E-408
ENLARGED LLTG PLAN AFTER - SECTOR 06
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-06
AFTER ALTERATIONS
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
C
M
M
C
M
M
C
M
M
C M M C M MC M M
S U R F A C E
P L A T E
C M M C M M C M MF M S
F
M
S
GAGE CAB
GAGE CAB
GAGE CAB
GAGE CAB
C U B I C L E C U B I C L E
C U B I C L E C U B I C L E
FIRE CAB
T 8 0 0 0
T
8
000
O P T I C
C F M
C F M
B l o c k
L a m b d a
H e a d
L a m b d a
C r a n k & A s s y
L a m b d a
Plate
Warming
600
Mahr PLM
Plate
Surface
Instrument Storage
Plate
Surface
Loader
Torque
E n g r a v e r
L a s e r
F i l t e r
L a s e r
S t a n d
T o r q u e
Bench
Electrical
Bench
Pressure
Inora
Faro
podTri
S t o r a g e
Instrument Storage
I n s t r u m e n t S t o r a g e
Instrument Storage
Plate
Surface
Cart
Cart
F i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e s
F i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e s
C o m p
G a g e B l o c k
Cabinet
Shoe
Case
Book
C U B I C L E
C U B I C L E
Shower
Air
C
o
p
ie
r
Cart
Cart
Cart
Cart
Cart
Cart
F i l e sF i l e s
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
Zoller
W
h
e
e
l R
a
c
k
U
N
IS
E
T
- v
M
o
v
a
b
le
H
o
is
t
Turn Mill Setting
UNISET - H
W
a
s
h
in
g
M
/C
P
o
w
e
r H
o
u
s
e
M
o
v
a
b
le
H
o
is
t
Tool Cabinet
G
ra
n
ite
T
a
b
le
T
o
o
l C
a
b
in
e
t
1
to
n
1
to
n
1
to
n
1
to
n
0
.5
to
n
0
.7
to
n
2
to
n
0
.5
to
n
S
V
P
3
G
/D
M
/C
1
to
n
G
rin
d
e
r
R
E
L
O
C
A
T
E
D
1
T
O
N
H
O
IS
T
Zoller 1
to
n
Zoller 1
to
n
(B
Y
O
T
H
E
R
S
)
64-0"
6
4
-
0
"
64-0" 64-0"
1
0
K
L
9
C
O
N
F
. R
M
E
S
T
E
S
T
R
M
M
IP
1
1
2
C
A
L
IB
R
A
T
IO
N
1
1
4
T
O
O
L
R
O
O
M
1
1
5
D
IS
-
A
S
S
E
M
B
L
Y
1
1
9
C
O
N
F
. R
M
1
1
0
A
R
C
H
IV
E
1
1
1
M
IP
&
C
A
L
.
1
1
3
M
A
T
. L
A
B
1
1
8
T
O
O
L
R
O
O
M
1
1
6
T
O
O
L
R
O
O
M
1
1
7
8 7
19-6" 44-6" 31-1" 29-9" 3-2"
4-11" 22-5"
15-10" 46-11" 31-0" 35-0" 15-6" 25-3" 22-6" 22-5"
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN 1
_
16-3" 25-3" 22-6"
4-11"
L
T
G
-
K
-
1
0
/
1
,
3
,
5
PS
L
T
G
-
K
-
1
0
P
U
S
H
B
U
T
T
O
N

S
T
A
T
I
O
N

P
B
S
-
1
O
N

R
O
O
F
P
H
O
T
O
C
E
L
L

9
9
9
9 9
9
9 9
S S
S S
S
9
9
1
3
1
3
7 7 7 7
1
3
7 7 7 7 7
7 7 7 7 7
7 7 7 1
3
7
7 7 7 7 7
S
J
EMLTG-E-7/D-13
S
S
7
7
7
7
7
7 7
7
7
7
7
5
a
5
a
5
a
5
a
5
a
5
a
5
a
5
a
5
a
5
a
5
b
5
b
5
b
5
b
5
b
S S
S S
J
S S
5
5
5
S
1
3
1
3
1 1
a
/
b
J
1
3
3
b
3
a
3
a
1
3
3
b
C
H
A
N
G
E

E
X
I
S
T
I
N
G

A
N
D

N
E
W

L
I
G
H
T
I
N
G

F
I
X
T
U
R
E
S
N
O

C
H
A
N
G
E
S
S
S S S S
1
a
1
b
1
a
1
b
1
a
1
b
1
b
1
a
1
3
1
a
1
a
1
a
1
a
1
b
1
b
1
b
1
b
1
3
1
3
1
c
1
c
1
c
1
c
1
d
1
d
1
d
1
d
S S S
1
b
1
a
1
c
1
b
1
b
1
a
1
c
1
3
1
3
1
b
1
b
X
A
L
T
G
-
K
-
9
3
b
S S S
3
c
3
a
3
a
3
b
3
c
3
b
3
c
3
a
3
b
3
c
3
a
3
b
3
c
3
a
S
S
S
J
3
a
3
b
3
c
3
b
3
a
3
c
3
b
3
a
3
c
3
b
3
a
3
c
3
b
3
a
3
c
3
b
3
a
8
8
8
88
8
3
c
3
c
3
b
3
a
88
8
8
8
88
8
8
8
8
L
T
G
-
K
-
9
/
1
L
T
G
-
K
-
9
/
1
,
3
S
5
a
5
b
SS
5
a
5
b
5
b
5
b
5
c
5
c
5
c
5
c
5
c
5
c
SS
5
b
5
b
5
b
5
b
5
a
5
a
5
a
5
a
2
a
2
b
2
c
2
d
S S S S
2
a
2
a
2
a
2
a
L
T
G
-
K
-
9
/
2
2
b
2
b
2
b
2
c
2
c
2
c
2
c
2
c
2
d
2
d
2
d
2
b
2
d
2
d
2
b
S
S
2
a
2
a
2
a
2
a
2
b
2
b
2
b
2
b
X
APS
9
9
9
9 S
1
3
1
3
3
b
3
a
3
a
1
3
3
b
N
O

C
H
A
N
G
E
S
S
S S S S
1
a
1
b
1
a
1
b
1
a
1
b
1
b
1
a
1
3
1
a
1
a
1
a
1
a
1
b
1
b
1
b
1
b
1
3
1
3
1
c
1
c
1
c
1
c
1
d
1
d
1
d
1
d
S S S
1
b
1
a
1
c
1
b
1
b
1
a
1
c
1
3
1
3
1
b
1
b
X
A
L
T
G
-
K
-
9
3
b
S S S
3
c
3
a
3
a
3
b
3
c
3
b
3
c
3
a
3
b
3
c
3
a
3
b
3
c
3
a
S
S
S
J
3
a
3
b
3
c
3
b
3
a
3
c
3
b
3
a
3
c
3
b
3
a
3
c
3
b
3
a
3
c
3
b
3
a
8
8
8
88
8
3
c
3
c
3
b
3
a
88
8
8
8
88
8
8
8
8
L
T
G
-
K
-
9
/
1
L
T
G
-
K
-
9
/
1
,
3
5
a
5
b
5
a
5
b
5
b
5
b
5
c
5
c
5
c
5
c
5
c
5
c
SS
5
b
5
b
5
b
5
b
5
a
5
a
5
a
5
a
2
a
2
b
2
c
2
d
S S S S
2
a
2
a
2
a
2
a
L
T
G
-
K
-
9
/
2
2
b
2
b
2
b
2
c
2
c
2
c
2
c
2
c
2
d
2
d
2
d
2
b
2
d
2
d
2
b
S
S
2
a
2
a
2
a
2
a
2
b
2
b
2
b
2
b
S
E
E

E
N
L
A
R
G
E
D

P
A
R
T

P
L
A
N
S
E
E

D
W
G

N
O

I
M

-

E

-

4
0
9

LTG-E-6/J-5
1
IM-E-409
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
ENLARGED LTG PLAN- OFFICE AREA
OFFICE AREA
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
64-0" 64-0" 64-0"
4 3 2
R
A
W
M
A
T
E
R
IA
L
R
M
1
2
0 M
A
IN
T
E
N
A
N
C
E
O
F
F
IC
E
1
2
2
M
A
IN
T
E
N
A
N
C
E
P
A
R
T
S
R
O
O
M
1
2
3
M
A
C
H
IN
IN
G
A
R
E
A
1
2
1
5
6-6"
16-8" 35-0" 12-4" 57-0" 7-0"
44-1" 16-8" 19-11"
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN MAINTEANCE 1
_
L
T
G
-
E
-
3
/
J
-
2
EMLTG-E-7/E-10
LTG-E-3/J-13
(TYP)
(TYP)
X
B
F
B
F
B
H
A
J
H
A
T
C
H

R
E
-
U
S
E

E
X
I
S
T
I
N
G
.
A
H
T
C
H

R
E
-
U
S
E

E
X
I
S
T
I
N
G
.
J
C
H
A
N
G
E

E
X
I
S
T
I
N
G

A
N
D

N
E
W

L
I
G
H
T
I
N
G

F
I
X
T
U
R
E
S
R
E
-
U
S
E
D

E
X
I
S
T
I
N
G
R
E
-
U
S
E
D

E
X
I
S
T
I
N
G
R
E
-
U
S
E
D

E
X
I
S
T
I
N
G
L
P
-
E
-
K
/
4
JJ J
SS
SS SSSS
1
d
1
c
1
b
1
a
1
b
1
d
1
c
1
a
1
b
1
d
1
c
1
a
1
b
1
d
1
c
1
a
1
b
1
d
1
c
1
a
1
b
1
d
1
0
1
a
1
0
1
0
1
0
1
c
L
P
-
E
-
K
/
4
-
3
3
a
3
a
3
b
3
a
3
a
3
a
3
a
3
b
3
b
3
b
3
b 2
2
J
1
0
1
0
SS S
5
a
5
b
5
b
5
c
S
E
E

E
N
L
A
R
G
E
D

P
A
R
T

P
L
A
N
S
E
E

D
W
G

N
O

I
M

-

E

-

4
1
0

J
J
E
M
L
T
G
-
E
-
7
/
D
-
1
2
C
O
O
L
A
N
T

B
A
S
E
M
E
N
T

F
L
O
O
R
E
M
E
R
G
E
N
C
Y

L
I
G
H
T
I
N
G

C
O
N
N
E
C
T
I
O
N
S
E
E

C
O
O
L
A
N
T

S
U
B
S
T
R
U
C
T
U
R
E


L
I
G
H
T
I
N
G

P
L
A
N
S
E
E

D
W
G
.

N
O

I
M
-
E
-
4
1
2
LTG-E-3/J-9
L
T
G
-
E
-
3
/
J
-
2
LTG-E-3/J-13
F
B
H
A
L
P
-
E
-
K
/
4
-
1
L
P
-
E
-
K
/
4
-
5
1
IM-E-410
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
ENLARGED LTG PLAN- SHOP AREA
SHOP AREA
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
4
8
-
0
"
64-0" 64-0"
A
B
3 2 1
B
R
E
A
K
R
M
1
3
0
L
O
C
K
E
R
R
M
(W
)
L
O
C
K
E
R
R
M
(M
)
R
E
S
T
R
M
(M
)
S
H
O
W
R
M
(M
)
1
3
6
S
H
O
W
R
M
(W
)
1
3
5
1
3
1
IT
R
M
1
3
8
1
3
2
1
3
4
1
3
7
J
A
N
IT
O
R
R
M
R
E
S
T
R
M
(W
)
1
3
3
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN BREAK ROOM 1
_
22-0" 42-0" 10-2" 10-4" 29-10" 7-4" 6-4"
J
L
P
-
E
-
A
/
1
S
3
S
3 S
3
S
3
S S
S
S
S
S
1
a
1
a
1
a
1
a
1
a
1
b
1
b
1
b
1
b
1
b
1
b
1
c
1
c
1
c
1
c
1
c
1
c
1
d
1
d
1
d
1
d
1
d
1
d
S S
P
G
-
E
-
K
/
1
-
1
L
P
-
E
-
K
/
1
-
1
,
3
L
P
-
E
-
K
/
1
-
5
3
3
3
3
3
3
3
3
3
3
3
3
3
3 3
5
5
5
5
3
3
3 3
3
3
3
3
3
TO EMLTG-7/0-9
9
9
J
9
9
J
9
9
9
9
9
9
9
9 9 9
3
3
3
S
E
E

E
N
L
A
R
G
E
D

P
A
R
T

P
L
A
N
S
E
E

D
W
G

N
O

I
M

-

E

-

4
1
1

C
H
A
N
G
E

E
X
I
S
T
I
N
G

A
N
D

N
E
W

L
I
G
H
T
I
N
G

F
I
X
T
U
R
E
S
LTG-E-3/C-1
LTG-E-3/C-3
60/60
1
IM-E-411
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
ENLARGED LTG. PLAN- BREAK AREA
BREAK AREA
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
4 3 25
ENLARGED COOLANT PIT PLAN 1
_
AREA
COOLANT PIT
AREA
COOLANT PIT
AREA
COOLANT PIT
EXIT LADDER UP
EXIT STAIR UP
ALL LIGHTING FIXTURE SHALL USED THE EXISTING MATERIALS.
COOLANT SUBSTRUCTURE
XA
(TYP)
HA
XA XA
J
SEE DWG NO. IM-E-402.
TO EMLTG -E 7/D-12
1
IM-E-412
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
COOLANT PIT
LIGHTING PLAN
ENLARGED
ENLARGED LTG PLAN- COOLANT PIT
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
7
6
5
42-8"
UPS
140
ELEC. RM
141
Ax
A 404
1
E
M
L
T
G
-
E
-
7
/
D
-
7
EMLTG-E-7/D
NEW SUBSTATION
XA
S
S
S
S
S
XA
SA
EMLTG-E-7/D-15
SEE ENLARGED PART PLAN
SEE DWG NO IM - E - 413
L
T
G
-
E
-
7
/
C
-
1
L
T
G
-
E
-
7
/
C
-
1
2
1
IM-E-413
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
ENLARGED LTG. PLAN- SUBSTATION
SUBSTATION
LIGHTING PLAN
ENLARGED
ARCH D AS SHOWN
Titles
Sheet
Individual
SHT. FILE #
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
12" (MAX)
4"
3 (MIN)
4"



5
SIDE WALL
CEILING
A/C SUPPLY
DIFFUSER
NOTE: MEASUREMENTS
SHOWN ARE TO THE
CLOSEST OF THE
24" MIN HANDICAP
BEDROOM STROBE
EDITION (SECTION 2-8.1)
42" MIN/54" MAX (NFPA)
48" MAX (ADA)
NFPA 72 1999
DOOR
WIDTH
96" MAX
EDITION
80" MIN
NFPA 72 1999
(SECTION 4-4.4)
SYNCHRONIZE MORE THAN
TWO APPLIANCES IN ANY
FIELD OF VIEW, SPACED A
MINIMUM OF 55 FROM EACH
OTHER IN ROOMS 80 x 80
OR GREATER.
NFPA 72 1999 EDITION
(SECTION A-4-4.4.1.1(1))
DETECTOR.
LESS 3"
6"
DEVICES
& VISUAL-ONLY
AUDIO/VISUAL
STATION
PULL
MANUAL
FLOOR
FINISHED
WALL
FINISHED
HERE
NEVER
JACK
PHONE
FIRE
HOLDER
DOOR
MAGNETIC
ACCEPTED HERE
DETECTOR
SMOKE/HEAT
WALL MOUNTED
DETECTOR
SMOKE/HEAT
CEILING MOUNTED
FIRE FIRE
SUPPLIED BY SIMPLEXGRINNELL
SYMBOL DESCRIPTION
FIRE ALARM CONTROL PANEL
IDNET ADDRESSABLE PULL STATION
SMOKE SENSOR W/ BASE
DUCT SMOKE SENSOR
ENCAPSULATED RELAY
HEAT SEBNSOR W/ BASE
INDIVIDUAL ADDRESSABLE MODULE W/ BRACKET
WATERFLOWSWITCH
TAMPER SWITCH
STROBE ONLY, WALL MOUNTED
75 = 75 CANDELA
SPEAKER/STROBE COMBINATION
END-OF-LINE RESISTOR (EOL)
FIRE ALARM SYMBOLS LEGEND
MODEL#

SIMPLEX 4100-9111




SIMPLEX 4099-9003

SIMPLEX 4098-9714 SENSOR
SIMPLEX 4098-9792 BASE

SIMPLEX 4098-9756



SIMPLEX 4098-9843


SIMPLEX 4090-9001








SIMPLEX 4904-9351




SUPPLIED BY OTHERS

BACKBOX








MOUNT TO DUCTWORK



SINGLE GANG BOX 2 1/8" DEEP

4" OCTAGONAL BOX 1 1/2" DEEP

SINGLE GANG BOX 2 1/2" DEEP WITH COVER






4" SQUARE BOX 1 1/2" DEEP W/ 1 1/2" RING

4" SQUARE BOX 1 1/2" DEEP



SUPPLIED BY OTHERS

(AIR PROD PAM-SD)
GRAPHIC COMMAND CENTER SUPPLIED BY SIMPLEXGRINNELL SIMPLEX 4190-8101
ADDRESSABLE RELAY IAM SIMPLEX 4090-9002 4" SQUARE BOX 2 1/8" DEEP
4" OCTAGONAL BOX 1 1/2" DEEP
LOCAL MODE TRANSPONDER
# = PANEL NUMBER SUPPLIED BY SIMPLEXGRINNELL
70 VOLT WALL MOUNT SPEAKER ATLAS SOUNDOLIER AP-15TUCR
SIMPLEX 4098-9733
PRESSURE SWITCH
110 = 110 CANDELA
110 = 110 CANDELA
75 = 75 CANDELA
SIMPLEX 4904-9352
ISOLATED LOOP CIRCUIT PROTECTOR SIMPLEX 2081-9044 4" SQUARE BY 2 1/8" DEEP
W/ 1 1/2" EXTENSION RING
BY OTHERS BY OTHERS
BY OTHERS BY OTHERS
BY OTHERS BY OTHERS
BEAM SMOKE DETECTOR
TR = TRANSMITTER
P = PRISM REFLECTOR
FIRERAY 50R
SIMPLEX 4100-9142 W/ VOICE COMMAND CENTER
NETWORK DISPLAY UNIT
TRUEALERT CONTROLLER SIMPLEX 4009-9401
REMOTE ANNUNCIATOR W/ LCD DISPLAY
WET CHEMICAL FIRE SYSTEM BY OTHERS BY OTHERS
S = SUPPLY
R = RETURN
DOOR TAG N/A N/A
PRE-ACTION CONTROL PANEL BY OTHERS BY OTHERS
LOWAIR PRESSURE SWITCH BY OTHERS BY OTHERS
SUPPLIED BY SIMPLEXGRINNELL
BY OTHERS ANSUL FIRE PROTECTION SYSTEM BY OTHERS
SIMPLEX 4905-9816 TRUEALERT ADAPTER MODULE
WP = WEATHERPROOF
SPEAKER/STROBE COMBINATION
WHEELOCK ET70WP-2475W-FR
15 = 15 CANDELA SIMPLEX 4904-9350
REMOTE TEST STATION SINGLE GANG BOX 2 1/8" DEEP SIMPLEX 2098-9806
SIMPLEX 4090-9101 MONITOR ZAM
SIMPLEX 4100-9111
SIMPLEX 4190-9611
PROGRAMMABLE 4-CIRCUIT TIMER SIMPLEX 6100-9002 SUPPLIED BY SIMPLEXGRINNELL
PRINTER SIMPLEX 4190-9013 N/A
SIMPLEX 3400-9817 1000VA SMART UNIVERSAL POWER SUPPLY N/A
POST INDICATOR VALVE BY OTHERS BY OTHERS
# = PANEL NUMBER SUPPLIED BY SIMPLEXGRINNELL
# = PANEL NUMBER
MOUNT USING WALL MOUNTING BRACKET (INCLUDED)
SIMPLEX 4098-9792 BASE
SIMPLEX 4090-9810
15 = 15 CANDELA
SIMPLEX 4903-9352
SIMPLEX 4903-9351
SIMPLEX 4903-9350
WHEELOCK IOB-R
SUPPLIED BY SIMPLEXGRINNELL
4 11/16" SQUARE BY 2 1/8" DEEP
4" SQUARE BOX 2 1/8" DEEP
4" SQUARE BOX 2 1/8" DEEP
SINGLE GANG BOX 2 1/8" DEEP
3-98
110
75
75
110
75
WP
15
15
F
F
F
F
WCS
LA
PS
VS
WF
TA
MZ
M
RT
FACP
TPS-#
GCC
NVCC
TAC-#
PACP
AFPS #
ANN
TIMER
PRN
UPS
PIV
ILCP
F
P
TR BD
BDPR
R SD
S SD
H
C
P R
SYMBOLS
CRITERIA,
FIRE ALARM
FIRE ALARM SYSTEM CRITERIA
TYPICAL FIRE ALARM DEVICE MOUNTING DETAIL
IM-FA-100
Mr. Ralph Noland
Contact Local SimplexGrinnell At 205-948-3200
1- The Existing Fire Alarm System Is SimplexGrinnell,
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
BLOCK
CRANK
HEAD HEAD-SUB
ASSEMBLY
COOLANT
6
4
-
0
"
48-0" 64-0" 64-0 1/16" 64-0" 64-0" 62-0" 64-0" 64-0" 64-0" 64-0"
ELEC. ROOM
MEASURING RM
CALIBRATION RM
MATERIAL AREA
CELL3
CELL2
CELL1
OFFICE
CONF. RM
SUB-MATERIAL RM
BREAK RM OPEN OFFICE
2-0"
624-0"
5
7
6
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
SHIPPING/ RECEIVING
10
A B D E F G H J K L C
9
8
7
6
5
4
3
2
1
Fx
SHIPPING/ RECEIVING
PURITY PARTS
STORAGE
ENGINE TEST
TOOL RM
ES TEST RM
SPINDLE RM
TOOL RM
TOOL RM
1ST FLOOR PLAN BEFORE CHANGE 1
_ SCALE: 1/32" = 1-0"
ARCH D 050 FT 100 FT 150 FT 200 FT
P I V P I V
P I V
AI L C P
Ao
6.8K EOL 6.8K EOL
MES LOW VOLTAGE CABLE TRAY
1@
12" WIDE ELEV. 29-0"
DIVIDERS FOR FA/TELE
1@
12" WIDE ELEV. 29-0" WITH
P I VP I V
F
P I V
FF FF F
P I VP I V
FF FF
F
F
FFF
F
F
F F
F
F
FF
F
F
F
F
F
F
F
F
F
FF
F
F
F
F
FFF
F
F
F
F
F
FF
F FFF
FF
PIV
PIV
F
F
P
F
F
F F
F
F
F
F F
F
P
P
F
F
F
F
F
F F
F
F
F
P
P
P
F
FACP
NODE 6
FACP
1W75
N6:TPS1:1-1-1
N6:SPK16-1
75
N6:TPS1:1-1-2
N6:M1-L1-1
P
B,S
N6:M1-L1-11
N6:M1-L1-2
2B,E,M,2S
P A C P
EOL
6.8K
EOL
6.8K
M M
A
LA
M
EOL
6.8K
PS
M
EOL
6.8K
E,M N6:M1-L1-4
N6:M1-L1-3
N6:M1-L1-7
N6:M1-L1-6
VS
M
EOL
6.8K
N6:M1-L1-5
A A
E,M E,M E,M E,M
E,M
E,M
N6:M1-L1-8
P
M
N6:M1-L1-9
E,M
E,M
E,M
SD
2B,E,M,S
N6:M1-L2-20
15 N6:TPS1:1-1-3B,E,M
N6:M1-L1-10
B,E,M
SD
N6:M1-L2-21
2B,E,M,S SD
SD
2B,E,M,S
N6:M1-L2-22
2B,E,M,S
N6:M1-L2-23
400 MAXIMUM
2B,E,M,S
1W110
N6:TPS1:1-2-2
N6:SPK15-2
2B,2S
1W110
N6:TPS1:1-2-1
N6:SPK15-1
5B,2E,4M,7S
2B,E,M,S
N6:TPS1:1-2-3 15
B
15
N6:TPS1:1-2-4
2B,E,M,S
1W75
N6:TPS1:1-2-5
N6:SPK15-3
B
15
N6:TPS1:1-2-6
B,E,M,S
N6:M1-L2-24
2S
N6:SPK13-1
3.8W
2S
N6:SPK1-1
E,M,2S
B,E,M,S
1W110
N6:TPS1:2-1-1
N6:SPK15-4
B,E,M,S
.5W15
N6:TPS1:2-1-2
N6:SPK15-5
SD
SD
E,M
E,M
N6:M1-L2-26
M
RETURN TO FACP
B 75N6:TPS1:2-1-3
N6:M1-L2-25
B,S
1W110 N6:TPS1:2-1-4
N6:SPK15-6
B
1W110 N6:TPS1:2-1-6
N6:SPK15-7
75
N6:TPS1:2-1-5
N6:SPK15
10K EOL
E,M,S
E,M,S
2S
N6:SPK13-2
SD
SD
E,M,SN6:M1-L3-30
N6:M1-L3-31
2M
N6:M1-L3-32 A
WF
6.8K
EOL
M
WF
6.8K
EOL
M
AE,M,S
E,M,S
N6:M1-L3-33
N6:M1-L3-34
I L C P
M
A
N6:M1-L3-35
E,M,S
400 MAXIMUM
Ao
Ao
SD
SD
E,2M
N6:M1-L3-37
N6:M1-L3-36
E,M,S
E,M,S
N6:SPK13-3
2S
E,M,S
2S
N6:SPK13-4
2M
N6:M1-L3-38
2M
N6:M1-L3-39
2S
N6:SPK13-5
E,M,S
E,M,S
E,M,S
E,M,S
B
N6:TPS1:3-1-4
N6:TPS1:3-1-3
15
15
B
E,M,2S
SE,MB,E,M
S
S
2S
N6:SPK1-2
2S
N6:SPK1-3
M
N6:M1-L3-40
2M,S
2S
N6:SPK1-4
E,M,S
E,M,S
E,M,S
N6:SPK1-5
2M,S
2M
N6:M1-L3-44
2M,S
A
WF
6.8K
EOL
M
WF
6.8K
EOL
M
A
2M,S
N6:M1-L3-43
N6:M1-L3-42
I L C P
M
A
N6:M1-L3-41
2M,S
6.8K EOL
AoAo
E,M,S
2S
N6:SPK1
10K EOL
N6:SPK1-7
N6:SPK1-6
2S
S
S
FOR CONTINUATION
SEE DRAWING FA-1.05
S (TO N6:SPK13-6)
2M
N6:M1-L3-45
SD
SD
E,2M
N6:M1-L3-46
N6:M1-L3-47
E,M
E,M
S
S
N6:SPK2-2
SD
SD
E,2M
N6:M1-L3-49
N6:M1-L3-50
2M N6:M1-L3-48
N6:SPK2-3
N6:SPK2
10K EOL
B
M,2S
2M
2S
N6:SPK2-1
N6:M1-L3-60
M
N6:M1-L3-59
B,M
N6:TPS1:2-2-215
B
2M
B,2S
1W110
N6:TPS1:2-2-1
N6:SPK14-1
3B,M,S
3B,S
4B,M,S
2B
15
N6:TPS1:3-1-1
B
15N6:TPS1:3-1-2
2B,M,S
B,2S
1W75
N6:TPS1:2-2-3
N6:SPK14-2
F
2S
N6:SPK14-3
3.8W
2M
N6:M1-L3-58
2M
2M
N6:M1-L3-57
N6:M1-L3-56
B,M,S
N6:M1-L3-55
B,M,S
P
N6:M1-L3-54
B,M,S
N6:M1-L3-53
B,M,S
M
SD
B,S
E,M
SD N6:M1-L3-52
N6:M1-L3-51
1W110
N6:TPS1:3-2-1
N6:SPK14-4
2E,2M
E,M
B,S
1W110
N6:TPS1:3-2-2
N6:SPK14-5
N6:SPK14
10K EOL
3B,M,2S
MES LOW VOLTAGE CABLE TRAY
2@
12" WIDE ELEV. 27-6"
1@
24" (120V) WIDE ELEV. 29-0"
MES LOW VOLTAGE CABLE TRAY
2@
12" WIDE ELEV. 27-6"
1@
12" (120V) WIDE ELEV. 29-0"
ELEV. 29-0"
TO MES PATCH PANEL
12" WIDE CABLE TRAY DOWN
MES LOW VOLTAGE CABLE TRAY
2@
12" WIDE ELEV. 27-6"
1@
24" (120V) WIDE ELEV. 29-0"
MES LOW VOLTAGE CABLE TRAY
2@
12" WIDE ELEV. 27-6"
MES LOW VOLTAGE CABLE TRAY
2@
12" WIDE ELEV. 27-6"
1@
12" (120V) WIDE ELEV. 29-0"
MES LOW VOLTAGE CABLE TRAY
2@
12" WIDE ELEV. 27-6"
1@
12" (120V) WIDE ELEV. 29-0"
MES LOW VOLTAGE CABLE TRAY
1@
12" WIDE ELEV. 29-0"
DIVIDERS FOR 120V/FA/TELE
1@
18" WIDE ELEV. 29-0" WITH
1@12" (120V) WIDE ELEV. 29-0"
2@12" WIDE ELEV. 27-6"
MES LOW VOLTAGE CABLE TRAY
1@24" (120V) WIDE ELEV. 29-0"
2@12" WIDE ELEV. 27-6"
MES LOW VOLTAGE CABLE TRAY
5B,2E,4M,7S
5B,E,3M,5S
2S
N6:SPK7-1
M,2S
N6:SPK7-2
5B,E,2M,5S
2S
N6:SPK7-3
E,M,S
N6:SPK7-4
SD
SD
E,2M
N6:M1-L4-73
N6:M1-L4-722E,2M
2S
E,M,S
M
N6:M1-L4-70
M
N6:M1-L4-71M
2B,M,2S
2B,2S
S
S
N6:SPK8-2
N6:SPK8-3
M
2S
N6:SPK8-1
SD
SD
N6:M1-L1-12
B,E,M,S
N6:M1-L1-13
B,E,M,S
B,M,S15
N6:TPS1:1-1-4
B
15
N6:TPS1:1-1-5
B,M,S
1W110
N6:TPS1:1-1-6
N6:SPK16-2
M
M RETURN TO FACP
N6:M1-L1-14
N6:SPK16
10K EOL
SD
N6:M1-L4-94
SD
N6:M1-L4-93
E,M
S
N6:SPK8-4
N6:SPK8
10K EOL
M,S
M
6.8K
ILCP M
MA
A
WF
M
M
EOL
6.8K
EOL
WF
A
E,M
6.8K EOL
4 0 0 M A X I M U M
Ao
Ao
SD
N6:M1-L4-89SD
N6:M1-L4-88
E,2M
E,M
E,M
N6:M1-L4-87
2M
2S
N6:SPK17-3
N6:M1-L4-90
N6:M1-L4-91
N6:M1-L4-92
M
SD
N6:M1-L4-86SD
N6:M1-L4-85
E,2M
E,M,2S
2B,2S
1W15
N6:TPS1:3-3-2
N6:SPK17-2
E,M,2S
2B,2S
1W15
N6:TPS1:3-3-1
N6:SPK17-1
B,E,M,2S
B,2S
SD
N6:M1-L4-84
E,M
E,M
SD
N6:M1-L4-83
E,M
1W110
N6:TPS1:3-4-1
N6:SPK17-4
B,S
1W110
N6:TPS1:3-4-2
N6:SPK17-5
N6:SPK17
10K EOL
2B,S
SD
N6:M1-L4-82
SD
N6:M1-L4-81
E,M
SD
E,M
SD
E,M
N6:M1-L4-80
N6:M1-L4-79
S
E,M
N6:SPK7-6
N6:SPK7
10K EOL
E,M,S
N6:M1-L4-78
2M A
WF
M
WF
M
A
2M,S
N6:M1-L4-76
N6:M1-L4-75
I L C P
M
A
N6:M1-L4-74
2M,S
2S
6.8K
EOL
6.8K
EOL
Ao
6.8K
EOL
N6:SPK7-5
E,M,S
E,M,S
2M
N6:M1-L4-77
E,M,S
2B,E,M,S
M
E,M,S
B2S
E,M,2S
5B,E,M,5S
3B,M,2S
E,M
E,M
B,M,S
B
3B,M,3S
M
2E,2M
S
E,M,S
E,M,S
2B,S
JB
B,S
B
B
15
15
N6:TPS1:3-3-3
N6:TPS1:3-3-4
E,M
B,E,M
5B,2E,2M,5S
400 MAXIMUM
Ao
Ao
400 MAXIMUM
Ao
HVAC-400-18
RETURN FAN ON
MOUNT VFD FOR
DRAWING ELECTRICAL NOTES
1 01 IN = 32 FT 200 100
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING AREAS THAT
CLOUDED ITEMS INDICATE
OVERALL FIRE ALALRM BEFORE CHANGE
BEFORE CHANGES
FIRE ALARM
OVERALL PLAN
IM-FA-101
AND UPDATE THE EXISTING CONDITION DRAWINGS.
FA CONTRACTOR SHALL FIELD REVIEW
FIRE ALARM DRAWINGS. THUS THE
BUILDING AFTER THESE ORIGINAL
NOTE - THIS BAY WAS ADDED TO ORIGNAL
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4
-
0
"
48-0" 64-0" 64-0 1/16" 64-0" 64-0" 62-0" 64-0" 64-0" 64-0" 64-0" 2-0"
624-0"
5
7
6
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
6
4
-
0
"
10
A B D E F G H J K L C
9
8
7
6
5
4
3
2
1
Fx
301 A
2
CELL1
PURITY PARTS
STORAGE
OFFICE
CONF. RM
COOLANT(LOWER)
ENGING TEST
ES TEST RM
SUB-MATERIAL RM
MIP
112
SHOP
101
CALIBRATION
114
TOOL ROOM
115
BREAK RM
130
LOCKER RM(W)
LOCKER RM(M)
REST RM(W)
REST RM(M)
RAWMATERIAL AREA
120
MAINTENANCE OFFICE
122
MAINTENANCE PARTS AREA
REST RM(W)
124
REST RM(M)
125
123
DIS-ASSEMBLY
119
MACHINING AREA
121
CONF. RM
110
ARCHIVE
111
SHIPPING/ RECEIVING
102
SHOWER RM(M)
136
SHOWER RM(W)
135
131
IT RM
138
132
133
134
137
JANITOR RM
JANITOR RM
126
MIP & CAL.
113
VESTIBULE
103
CELL2
MAT. LAB
118
A 402
1
A 401
1
A 403
1
TOOL ROOM
116
TOOL AREA
117
OFFICE
301 A
1
42-8"
UPS
140
ELEC. RM
141
Ax
A 404
1
BLOCK
CRANK
HEAD
ASSEMBLY
HEAD SUB
CMM
CMM
CMM
CMM
CMM
CMM
SURFACE PLATECMM
CMM
CMM
FMS
FMS
GAGE CAB GAGE CAB GAGE CAB GAGE CAB
CUBICLE
CUBICLE
CUBICLE
CUBICLE
FIRE CAB
T8000T8000 OPTIC
CFMCFM
BlockLambda
HeadLambda
Crank & Assy
Lambda
Plate Warming
600 Mahr PLM
Plate Surface
Instrument Storage
Plate Surface
Loader Torque
EngraverLaser
FilterLaserStandTorque
Bench Electrical Bench Pressure Inora Faro pod Tri
Storage
Instrument Storage
Instrument Storage
Instrument Storage
Plate Surface
Cart
Cart
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
FilesCompGage Block
Cabinet Shoe Case Book
CUBICLE
CUBICLE
Shower Air
Copier
Cart
Cart
Cart
Cart
Cart
Cart
Files
Files
1/4 Ton Hoist
1/4 Ton Hoist
1/4 Ton Hoist
1/4 Ton Hoist
Zoller
Wheel Rack
UNISET - v
Movable Hoist
Turn Mill Setting
UNISET - H
Washing M/C Power House
Movable Hoist
Tool CabinetGranite Table
Tool Cabinet
1 ton 1 ton
1 ton
1 ton 0.5 ton 0.7 ton
2 ton
0.5 ton
SVP3 G/D M/C 1 ton
Grinder
Zoller
1 ton
Zoller
1 ton
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD SD SD
SD SD SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
SDSD SDSD SDSD SDSD
SD SD SD SD SD SD SD SD
SD SDSD SDSD SDSD SD
SD SD SD SD SD SD SD SD
10
9
8
7
6
5
4
3
2
1
A 404
1
A B D E F G H J K L C Fx
RELOCATED SHUTTER
NEWMAN DOOR
RELOCATED VESTIBULE
DRAWING ELECTRICAL NOTES
P I VP I V
F
P I V
FF FF F
P I VP I V
FF
FFF
F
F
F F
F
F
FF
F
F
F
F
F
F
FF
F
F
FFF
F
F
F
F
FF
F FFF
FF
PIV
PIV
F
F
P I V P I V
P I V
F
F
F F
F
P
P
P
NODE 6
P A C P
M M
LA
M
PS
M
VS
M
I L C P P
M
SD SD
SD
SD
SD
SD
SD
SD
WF
M
WF
M
I L C P
M
SD
SD
WF
M
WF
M
I L C P
MSD
SD
SD
SD
F
P
SD
SD
SD
SD
SD
SD
SDSD
ILCP M
WF
M
M
WF
SDSD
SDSD
WF
M
WF
M
I L C P
M
FF
F
F
F F F F F F F F
F
F
SD R
SD R
SD R
SD R
F F
F
F
F
FACP
FACP
SD R SD R
SD R
SD R
SD R
SD R
SD R
SD R
SD R
SD R
SD R
SD R SD R SD R
SD R
SD R
F
F
P
P
P
P
P
P
P
P
P
P
P P
P
P
P
P
P
P
P
P
P
P
P
P P
P P
P
P
P P P P
P
P
P
P
P
P
P P
P
P
P
P
P
P
P
P
P P
P
P
P
P
P
F
F
F
F
FF
F
F
F
F
F
F
F
F
FF
F
F
F
NVCC
GCC
FACP
1 01 IN = 32 FT 200 100
(NON-CLUDED REMAIN AS-IS)
ARE TO BE MODIFIED
THE EXISTING AREAS THAT
CLOUDED ITEMS INDICATE
OVERALL PLAN- FIRE ALARM AFTER CHANGE
AFTER CHANGES
FIRE ALARM
OVERALL PLAN
IM-FA-102
TIER-2 (2) 12 WIDE @27-6"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
(1) 12 WIDE @29-0"
(1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY
VIA CONVEYOUR BRIDGE
EXTENDS TO NEXT BUILDING
MES LV CABEL TRAY SYSTEM
(1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY
HVAC-400-18
HVAC-400-11
HVAC-400-13
HVAC-400-12
HVAC-400-10 HVAC-400-09
HVAC-400-08
HVAC-400-07
HVAC-400-06
HVAC-400-05
HVAC-400-19
HVAC-400-04
HVAC-400-??
HVAC-400-03
HVAC-400-22
HVAC-400-02 HVAC-400-03 HVAC-400-06
HVAC-400-21
HVAC-400-01
OFFICE AREA
ARE TO BE RELOCATED TO NEW
PANELS & RELATED COMPONENTS
EXISTING F.A. CONTROL SYSTEM
WITH OWNER & FIRE MARSHALL
& RELATED COMPONENTS- VERIFY
RELOCATED F.A. CONTROL PANELS
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY(NEW)
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY(NEW)
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY(NEW)
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY(NEW)
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY (NEW)
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY (NEW) TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY (EX)
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
6
4

-
0
"
48-0" 64-0"
64-0 1/16"
64-0" 64-0" 62-0" 2-0"
624-0"
6
4

-
0
"
A B D E F C Fx
SHIPPING/ RECEIVING
102
OFFICE
42-8"
UPS
140
Ax
SD SD SD SD SD SD SD SD SD SD SD SD
RELOCATED SHUTTER
NEW MAN DOOR
P I VP I V
F
P I V
FF
F
F
F
FFF
P
P
P
W
F
M
W
F
M
I L C P
M
S
D
S
D
S
D
S
D
P
S
D
S
D
F F F F F
F
F
SD R SD
SD R
SD R
P
(1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
HVAC-400-02 HVAC-400-03
HVAC-400-21
HVAC-400-01
ENLARGED F.A. PLAN AFTER - SECTOR 01
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-01
AFTER ALTERATIONS
FIRE ALARM PLAN
ENLARGED
IM-FA-111
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
62-0" 64-0" 64-0" 64-0" 64-0" 2-0"
624-0"
F G H J K L Fx
ES TEST RM
MIP
112
CALIBRATION
114
TOOL ROOM
115
CONF. RM
110
ARCHIVE
111
SHIPPING/ RECEIVING
102
MIP & CAL.
113
MAT. LAB
118
TOOL ROOM
116
TOOL AREA
117
301 A
1
HEAD SUB
CMM
CMM
CMM
C
M
M
C
M
M
C
M
M
SURFACE
PLATECMM
CMM
CMM
F
M
S
FMS
GAGE CAB GAGE CAB GAGE CAB GAGE CAB
CUBICLE
CUBICLE
CUBICLE
CUBICLE
FIRE CAB
T8000T8000
OPTIC
C
F
MCFM
Block
Lambda
Head
Lambda
Crank & Assy
Lambda
Plate Warming
600 Mahr PLM
Plate Surface
Instrument Storage
Plate Surface
Loader Torque
Engraver
Laser
Filter
Laser
Stand
Torque
Bench Electrical
Bench Pressure Inora Faro
pod Tri
Storage
Instrument Storage
Instrument Storage
Instrument Storage
Plate Surface
Cart
Cart
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Files
Comp
Gage Block
Cabinet Shoe Case Book
CUBICLE
CUBICLE
Shower
Air
Copier
Cart
Cart
Cart
Cart
Cart
Cart
Files
Files
1/4 Ton
Hoist
1/4 Ton
Hoist
1/4 Ton
Hoist
1/4 Ton
Hoist
Zoller
Wheel Rack
UNISET - v
Movable Hoist
Turn M
ill Setting
UNISET - H
Washing M/C Power House
Movable Hoist
Tool Cabinet
Granite Table
Tool Cabinet
1 ton 1 ton
1 ton
1 ton 0.5 ton
0.7 ton
2 ton
0.5 ton
SVP3 G/D M/C
1 ton
Grinder
Zoller
1 ton
Zoller
1 ton
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
SD SD SD SD SD SD SD SD
10
9
8
7
A 404
1
RELOCATED SHUTTER
NEW MAN DOOR
P I VP I V
FF
FF
S
D
S
D
W
F
M
W
F
M
I L C P
M
FF
F
F
F F F F
SD R
SD R
SD R
SD R
SD R
SD R
SD R SD R
P P
P
P
P
P
P
P
P
P
P
P
P
P P
P P
P
P
P P P P
F
F
F
F
FF
F
F
F
F
F
F
F
NVCC
GCC
FACP
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
HVAC-400-05
HVAC-400-19
HVAC-400-04
HVAC-400-??
HVAC-400-03
HVAC-400-22
HVAC-400-03 HVAC-400-06
WITH OWNER & FIRE MARSHALL
& RELATED COMPONENTS- VERIFY
RELOCATED F.A. CONTROL PANELS
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY(NEW)
ENLARGED F.A. PLAN AFTER - SECTOR 02
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-02
AFTER ALTERATIONS
FIRE ALARM PLAN
ENLARGED
IM-FA-112
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
SHOP
42-8"
UPS
140
ELEC. RM
141
Ax
ASSEMBLY
FFF
F
F
F F
F
F
F
F
F
F
F
F
F
F
P
P
P
F
P
S
D
S
D
SD R
F
F
P
P
P
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY
VIA CONVEYOUR BRIDGE
EXTENDS TO NEXT BUILDING
MES LV CABEL TRAY SYSTEM
(1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY
HVAC-400-01
ENLARGED F.A. PLAN AFTER - SECTOR 03
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-03
AFTER ALTERATIONS
FIRE ALARM PLAN
ENLARGED
IM-FA-113
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
CELL1
PURITY PARTS
STORAGE
OFFICE
CONF. RM
COOLANT(LOWER)
ENGING TEST
ES TEST RM
SUB-MATERIAL RM
SHOP
101
RAW MATERIAL AREA
120
MAINTENANCE OFFICE
DIS-ASSEMBLY
119
MACHINING AREA
121
CELL2
MAT. LAB
118
A 401
1
CRANK
HEAD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD
SD SD SD SD SD SD SD SD
A 404
1
FF
F
F
FFF
F
F
S
D
S
D
S
D
S
D
SD R
SD R
SD R
SD R
P
P
P
P
P
P P P P
P
P
P
P
P
P
P P
P
P
P
P
P
P
P
P
F
F
F
F
F
F
F
F
F
TIER-2 (2) 12 WIDE @27-6"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
HVAC-400-07
HVAC-400-06
HVAC-400-05
HVAC-400-19
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY(NEW)
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY(NEW)
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
ENLARGED F.A. PLAN AFTER - SECTOR 04
1 AS SHOWN 75 50 25
SECTOR-04
AFTER ALTERATIONS
FIRE ALARM PLAN
ENLARGED
IM-FA-114
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
5
7
6

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
6
4

-
0
"
301 A
2
BREAK RM
130
LOCKER RM(W)
LOCKER RM(M)
REST RM(W)
REST RM(M)
SHOWER RM(M)
136
SHOWER RM(W)
135
131
IT RM
138
132
133
134
137
JANITOR RM
VESTIBULE
103
A 403
1
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
A B D E F C Fx
RELOCATED VESTIBULE
F
F
FF
F F
FF
P I V P I V
F
F
S
D
S
D
S
D
S
D
W
F
M
W
F
M
I L C P
M
S
D
S
D
SD R
SD R
SD R
SD R
F F
F
F
F
SD R
P
P
P
P
P
P
P
(1) 12 WIDE @29-0"
(1) 12 WIDE 29-0"
MES/FA LV CABLE TRAY
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY
HVAC-400-18
HVAC-400-11
HVAC-400-13
HVAC-400-12
HVAC-400-10
ENLARGED F.A. PLAN AFTER - SECTOR 05
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-05
AFTER ALTERATIONS
FIRE ALARM PLAN
ENLARGED
IM-FA-115
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
COOLANT(LOWER)
120
MAINTENANCE OFFICE
122
MAINTENANCE PARTS AREA
REST RM(W)
124
REST RM(M)
125
123
MACHINING AREA
121
JANITOR RM
126
A 402
1
BLOCK
CRANK
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
SD SD
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
F G H J K L Fx
RELOCATED VESTIBULE
FF
P
IV
P
IV
F
F
F
F
F FNODE 6
P A C P
M M
L
A
M
P
S
M
V
S
M
I L C P
P
M
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
IL
C
P
M
W
F
M
M
W
F
S
D
S
D
F
A
C
P
F
A
C
P
SD R SD R
SD R
SD R
P
P
P
P
P
P
P
P
P
HVAC-400-10 HVAC-400-09
HVAC-400-08
HVAC-400-07
OFFICE AREA
ARE TO BE RELOCATED TO NEW
PANELS & RELATED COMPONENTS
EXISTING F.A. CONTROL SYSTEM
(12) 12 WIDE @29-0"
(1) 18 WIDE 29-0"
MES/FA LV CABLE TRAY(NEW)
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY (NEW)
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY (NEW)
TIER-2 (2) 12 WIDE @27-6"
TIER-1 (1) 24 WIDE 29-0"
MES/FA LV CABLE TRAY (EX)
ENLARGED F.A. PLAN AFTER - SECTOR 06
1 AS SHOWN 75 50 25
SECTOR KEY PLAN
01
SECTOR
02
SECTOR
03
SECTOR
04
SECTOR
05
SECTOR
06
SECTOR
SECTOR-06
AFTER ALTERATIONS
FIRE ALARM PLAN
ENLARGED
IM-FA-116
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
C
M
M
C
M
M
C
M
M
C M M C M MC M M
S U R F A C E
P L A T E
C M M C M M C M MF M S
F
M
S
GAGE CAB
GAGE CAB
GAGE CAB
GAGE CAB
C U B I C L E C U B I C L E
C U B I C L E C U B I C L E
FIRE CAB
T 8 0 0 0
T
8
000
O P T I C
C F M
C F M
B l o c k
L a m b d a
H e a d
L a m b d a
C r a n k & A s s y
L a m b d a
Plate
Warming
600
Mahr PLM
Plate
Surface
Instrument Storage
Plate
Surface
Loader
Torque
E n g r a v e r
L a s e r
F i l t e r
L a s e r
S t a n d
T o r q u e
Bench
Electrical
Bench
Pressure
Inora
Faro
podTri
S t o r a g e
Instrument Storage
I n s t r u m e n t S t o r a g e
Instrument Storage
Plate
Surface
Cart
Cart
F i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e s
F i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e sF i l e s
C o m p
G a g e B l o c k
Cabinet
Shoe
Case
Book
C U B I C L E
C U B I C L E
Shower
Air
C
o
p
ie
r
Cart
Cart
Cart
Cart
Cart
Cart
F i l e sF i l e s
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
H
o
is
t
1
/4
T
o
n
Zoller
W
h
e
e
l R
a
c
k
U
N
IS
E
T
- v
M
o
v
a
b
le
H
o
is
t
Turn Mill Setting
UNISET - H
W
a
s
h
in
g
M
/C
P
o
w
e
r H
o
u
s
e
M
o
v
a
b
le
H
o
is
t
Tool Cabinet
G
ra
n
ite
T
a
b
le
T
o
o
l C
a
b
in
e
t
1
to
n
1
to
n
1
to
n
1
to
n
0
.5
to
n
0
.7
to
n
2
to
n
0
.5
to
n
S
V
P
3
G
/D
M
/C
1
to
n
G
rin
d
e
r
R
E
L
O
C
A
T
E
D
1
T
O
N
H
O
IS
T
Zoller 1
to
n
Zoller 1
to
n
(B
Y
O
T
H
E
R
S
)
64-0"
6
4
-
0
"
64-0" 64-0"
1
0
K
L
9
C
O
N
F
. R
M
E
S
T
E
S
T
R
M
M
IP
1
1
2
C
A
L
IB
R
A
T
IO
N
1
1
4
T
O
O
L
R
O
O
M
1
1
5
D
IS
-
A
S
S
E
M
B
L
Y
1
1
9
C
O
N
F
. R
M
1
1
0
A
R
C
H
IV
E
1
1
1
M
IP
&
C
A
L
.
1
1
3
M
A
T
. L
A
B
1
1
8
T
O
O
L
R
O
O
M
1
1
6
T
O
O
L
R
O
O
M
1
1
7
8 7
19-6" 44-6" 31-1" 29-9" 3-2"
4-11" 22-5"
15-10" 46-11" 31-0" 35-0" 15-6" 25-3" 22-6" 22-5"
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN 1
_
16-3" 25-3" 22-6"
4-11"
F F
S
D
R
S
D
R
S
D
R
S
D
R
S
D
R
P
P
P
P P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
F
F
F
F
F
F
F
F
F
F
F
F F
F
F
N
V
C
C
G
C
C
F
A
C
P
H
V
A
C
-
4
0
0
-
0
5
H
V
A
C
-
4
0
0
-
1
9
H
V
A
C
-
4
0
0
-
0
4
H
V
A
C
-
4
0
0
-
?
?
H
V
A
C
-
4
0
0
-
0
3
W
I
T
H

O
W
N
E
R

&

F
I
R
E

M
A
R
S
H
A
L
L
&

R
E
L
A
T
E
D

C
O
M
P
O
N
E
N
T
S
-

V
E
R
I
F
Y
R
E
L
O
C
A
T
E
D

F
.
A
.

C
O
N
T
R
O
L

P
A
N
E
L
S
(
1
2
)

1
2

W
I
D
E

@

2
9
-
0
"
(
1
)

1
8

W
I
D
E

2
9
-
0
"
M
E
S
/
F
A

L
V

C
A
B
L
E

T
R
A
Y
(
N
E
W
)
1
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
ENLARGED F.A. PLAN- OFFICE AREA
IM-FA-117
OFFICE AREA
FIRE ALARM
ENLARGED
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
64-0" 64-0" 64-0"
4 3 2
R
A
W
M
A
T
E
R
IA
L
R
M
1
2
0 M
A
IN
T
E
N
A
N
C
E
O
F
F
IC
E
1
2
2
M
A
IN
T
E
N
A
N
C
E
P
A
R
T
S
R
O
O
M
1
2
3
M
A
C
H
IN
IN
G
A
R
E
A
1
2
1
5
6-6"
16-8" 35-0" 12-4" 57-0" 7-0"
44-1" 16-8" 19-11"
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN MAINTEANCE 1
_
F
F
PIV PIV
SD
SD
ILCP
M
WF
M M
WF
SD
SD
S
D
R
S
D
R
S
D
R
P P P
P
P
P
P
P
P
P
H
V
A
C
-
4
0
0
-
0
8
H
V
A
C
-
4
0
0
-
0
7
H
V
A
C
-
4
0
0
-
0
6
(
1
2
)

1
2

W
I
D
E

@

2
9
-
0
"
(
1
)

1
8

W
I
D
E

2
9
-
0
"
M
E
S
/
F
A

L
V

C
A
B
L
E

T
R
A
Y
(
N
E
W
)
1
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
ENLARGED F.A. PLAN- SHOP AREA
SHOP AREA
FIRE ALARM
ENLARGED
IM-FA-118
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
4
8
-
0
"
64-0" 64-0"
A
B
3 2 1
B
R
E
A
K
R
M
1
3
0
L
O
C
K
E
R
R
M
(W
)
L
O
C
K
E
R
R
M
(M
)
R
E
S
T
R
M
(M
)
S
H
O
W
R
M
(M
)
1
3
6
S
H
O
W
R
M
(W
)
1
3
5
1
3
1
IT
R
M
1
3
8
1
3
2
1
3
4
1
3
7
J
A
N
IT
O
R
R
M
R
E
S
T
R
M
(W
)
1
3
3
ARCH D - SCALE: 3/32" = 1-0"
ENLARGED 1ST FLOOR PLAN BREAK ROOM 1
_
22-0" 42-0" 10-2" 10-4" 29-10" 7-4" 6-4"
F
F
S
D
R
S
D
R
S
D
R
S
D
R
F
F
F
F
F
PP
P
P
P
P
P
H
V
A
C
-
4
0
0
-
1
8
H
V
A
C
-
4
0
0
-
1
1
H
V
A
C
-
4
0
0
-
1
3
H
V
A
C
-
4
0
0
-
1
2
1
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
ENLARGED F.A. PLAN- BREAK AREA
BREAK AREA
FIRE ALARM
ENLARGED
IM-FA-119
ARCH D AS SHOWN
SDG#: 1032
2011 MODIFICATIONS
THETA NU ENGINE SHOP
Architects & Engineers Co. Ltd.
307 Church Street, Suite B
SMITH DESIGN GROUP, INC.
LaGrange, Georgia 30240
Phone (706) 882-5511
Fax (706) 883-7777
www.smithdesigngroup.net
US Inc
1515 Hogansville Rd #148, LaGrange, GA 30241
HYUNDAI MOTOR
MANUFACTURING ALABAMA, LLC
HYUNDAI
Revision Date:
Creation-Date:
Released:
Proofed:
Drawn:
Project No:
Permit
Title
Index:
Approved for:
Scale:
File No:
INDEX DATE DESIGN CHANGE DRA. CHE.
NOTES:
Schematic Design Construction Documents
Sheet Size:
Signature Required Signature Required
Architects Stamp Engineers Stamp
Owner Review
Preliminary Pricing
03/25/2011
D E R E T S I G E
R
A M A
B
A
L
A
R E E N I G N E
X
O
D
D
A
M
N
A
G R O M T R E B O R
PROFESSIONAL
No. 14737
2011 03/25
GENERAL ELECTRICAL NOTES
Release For Permit Review & Pricing Only
4 3 25
ENLARGED COOLANT PIT PLAN 1
_
AREA
COOLANT PIT
AREA
COOLANT PIT
AREA
COOLANT PIT
EXIT LADDER UP
EXIT STAIR UP
P P P P P P
P P P P P P
FF
F F F
1
40 20 01 IN = 08 FT
SECTOR KEY PLAN
SUBSTATION
OFFICE
SHOP AREA
PIT BELOW
BREAK RM
ENLARGED F.A. PLAN- COOLANT PIT
COOLANT PIT
FIRE ALARM
ENLARGED
IM-FA-120

Anda mungkin juga menyukai