1.1 A steam boiler generates steam at 30 bar, 300C at the rate of 2 kg/s.
This steam is expanded
isentropically in a turbine to a condenser pressure of 0.05 bar, condensed at constant pressure and pumped back to boiler. a) Draw the schematic arrangement of the above plant and T-S diagram of Rankine Cycle. b) Find heat supplied in the boiler per hour c) Determine the quality of steam after expansion d) What is the power generated by the turbine? e) Estimate the Ranking efficiency considering pump work. Hint: P1= 30 bar, P2= 0.05 bar, T1 = 300C, m= 2 kg/s From Super-heated steam table @ 30 bar & 300C find Enthalpy h1 and Entropy S1 From Pressure table @ 0.05 bar Sf, Sfg then find x by equating S1=S2 and hf & hfg then find h2= hf2+hfg2 h3 = hf at P2 from pressure table Considering the pump work h4-h3=vf at P2(P1-P2) find h4 Heat supplied Qs = m(h1-h4) Power generated by the turbine WT= m(h1-h2) Rankine efficiency = WT-Wp/Qs = (h1-h2)-(h4-h3) / (h1-h4)
Reheat Cycle Problem 1.2 In a steam power plant operating on an ideal reheat Rankine cycle, the steam enters the high- pressure turbine at 3 MPa and 400C.After expansion to 0.6 MPa, the steam is reached to 400C and then expanded the low-pressure turbine to the condenser pressure of 10 kPa. Determine the thermal efficiency of the cycle and the quality of steam at the out let of the low pressure turbine.
1.3
5.1 Find the cost of generation per kW-hr from the following data: Capacity of the Plant - 140 MW Capital cost Rs. 1400 per kW installed Interest and depreciation 12% on capital Fuel Consumption 1.4 kg/kW-hr Fuel Cost Rs.45 tonne Salaries, wages, repairs and maintenance- 9,00,000/year. The maximum demand is 80 MW and load factor is 45%
5.2 Determine the generating cost per unit of 90 MW power station with the following data: Capital cost Rs. 170 x 10 7 , Annual Cost of Fuel = Rs.38 x 10 6 , Annual wages and taxes = 15 % of the Capital Cost, Annual load factor = 40%.
5.3 A central power station has annual factors as follows: Load factor = 50 % : Capacity factor = 45%, Use factor = 50%, power station has a maximum demand of 18,000 kW. Determine Annual energy production, Reserve capacity over and above peak load, hours per year not in service.