Anda di halaman 1dari 1

Operating 2-floor lifts with ARL-500 with encoder counter system

Step 1: Mount an additional door zone magnet between two floors (approximately in the middle)


























Step 2: Make the following settings in ARL-500 menu:

System settings -->Position sensing: Encoder
System settings -->Number of floors: 3
Door settings -->Door type settings -->Individual settings for floors
A
Floor-1: Auto
Floor-2: None
Floor-3: Auto
Display settings -->Floor texts -->Floor 3: Write the same floor text written for Floor 2
Encoder Settings -->Travel distances -->Slowing distance in high speed: The distance of 817 and 818
signals. The parameter 1.8-SLOWING DST. in ADrive should be set 15cm lower than this value
Encoder Settings -->Travel distances -->Stopping distance in low speed: To the same value with the
parameter 1.9-STOPING DST. in ADrive
Encoder Settings -->Hardware configuration -->Flag length: The length of the door zone magnet
Exit menu and select Yes to save parameters
Encoder settings -->Learn shaft
Elevator makes a learning run. After it finishes, exit menu and select Yes to save parameters
If the elevator control cabinet includes an automatic rescue (evacuation) function, then dismount the
additional door zone magnet between two floors after learning run is finished.

Step 3: Adjust the number of floor setting of the LOP placed on the 2
nd
floor as 3 instead of 2 (by menu or
dipswitches).

Step 4: Connect the car push button connector of the 2
nd
floor to the socket labeled as 3 instead of 2 on the
KABKON in the COP.

Door zone magnet
for 2nd floor
Door zone magnet
for 1st floor
Additional door zone
magnet between two
floors (in the middle)
ML2
ML1



CAR

Anda mungkin juga menyukai