Anda di halaman 1dari 4

PROPIEDAD

W (lb/h)
T1 (F)
T2 (F)
s1 (API)
Tc
Cp (BTU/lbF)

PROPIEDADES FLUIDOS
CALIENTE
60000
400
225
42
312.5
0.61

FRO
100
200
35
150
0.5

PROP. GENERALES SERVICIO


DE (in)
0.75
Tipo DE
16 BWG
L (ft)
16
PT (in)
0.9375
F max
0.004
DPmax (psi)
10
DI (in)
0.62

CLCULOS GENERALES
q (BTU/h)
6405000
w (lb/h)
128100
R
1.75
S
0.333333333
DMLT
159.5732359
FT (Fig. 18)
0.875
Dt
139.6265814
DISEO INTERCAMBIADOR 1-2 CON UN DEFLECTOR
Pasos en los tubos
2
Intervalo tentativo UD (Tabla 8)
Tentativa UD
65
A
705.7285264
2
a'' (in ) (Tabla 10)
0.1963
No. de tubos
224.6970601
No. de tubos ms cercano (Tabla9)
DIC (in) (Tabla 9)
17.25
A corregida
703.5392
UD corregido
65.20227191
CLCULOS TUBOS (FRO)
a't (in2) (Tabla 10)
0.302
at (ft2)
0.234888889
mfrio (cp) (Fig. 14)
2.2
mfrio (lb/ft h)
5.324
G (lb/h ft2)
545364.2384
Re
5292.477896
L/D
21.33333333
jH (Fig. 24)
19
k(cm/k)1/3 (Fig.16)
0.25
hi/ft
91.93548387
hi0/ft
76
f (Fig. 26)
0.00032
s (Fig. 6)
0.85

40-75

224

CLCULOS CORAZA (CALIENTE)


Bafles
1
B (in)
17.25
C' (in)
0.19
as (ft2)
0.41328125
Gs (lb/h ft2)
145179.5841
ms (cp) (Fig. 14)
0.38
ms (lb/ft h)
0.9196
de (ft)
0.044432227
Res
7014.628419
jh (Fig.28)
46
1/3
kc (cm/k) (BTU/h ft F) (Fig. 16)
0.145
h0 (BTU/h ft F)
150.1162645
N+1
11.13043478

DPt
V2/2g' (psi) (Fig 27)
DPr
DPT

1.328536213 f (Fig. 29)


0.04 s (Fig.6)
0.376470588 DPs (psi)
1.705006801

0.0023
0.715
0.467718216

r (lb/in3)

0.030707682 r (lb/in3)

0.025830579

Uc
Rd

50.45561905
-0.004482509

COSTOS
FRO
Costo
hB (ft)
WB (W)

CALIENTE
3983.034005 Costo ($/lb)
4.62698232 hB (ft)
223.2235952 WB (W)

6944.77724
1.508929305
34.09677253

PROPIEDADES FLUIDOS
PROPIEDAD
CALIENTE
W (lb/h)
29800
T1 (F)
340
T2 (F)
240
s1 (API)
35
Tc
280.5
Cp (BTU/lbF)
0.58

FRO
103000
200
230
48
212
0.56

PROP. GENERALES SERVICIO


DE (in)
0.75
Tipo DE
16 BWG
L (ft)
16
PT (in)
0.9375
F max
0.004
DPmax (psi)
10
DI (in)
0.62

CLCULOS GENERALES
q (BTU/h)
1730400
w (lb/h)
103000
R
3.333333333
S
0.214285714
DMLT
69.19724883
FT (Fig. 18)
0.885
Dt
61.23956521
DISEO INTERCAMBIADOR 1-2 CON UN DEFLECTOR
Pasos en los tubos
2
Intervalo tentativo UD (Tabla 8)
Tentativa UD

40-75

70
403.6606059

A
a'' (in2) (Tabla 10)
0.1963
No. de tubos
128.5215887
No. de tubos ms cercano (Tabla9)
DIC (in) (Tabla 9)
15.25
A corregida
389.4592
UD corregido
72.55250977
CLCULOS TUBOS
a't (in ) (Tabla 10)
2

at (ft )
mfrio (cp) (Fig. 14)
mfrio (lb/ft h)
G (lb/h ft2)

124

CLCULOS CORAZA
0.302 Bafles

0.130027778 B (in)

15.25

0.54 C' (in)

0.19

1.3068 as (ft )

0.323003472
2

792138.432 Gs (lb/h ft )

Re (Fig. 24)

31318.60447 ms (cp) (Fig. 14)

L/D
jH (fig. 24)
k(cm/k)1/3 (Fig.16)

21.33333333 ms (lb/ft h)
102 de (ft)
0.167 Res

hi/ft
hi0/ft

329.6903226 jh (Fig.28)
1/3
272.544 kc (cm/k)

92259.07014
0.38
0.9196
0.044432227
4457.672883
0.46
0.145

f (Fig. 26)
s (fig. 6)
DPT

0.0002 h0
0.72
2.068086501

1.501162645

Anda mungkin juga menyukai