Contoh Neraca Panas
Contoh Neraca Panas
Komponen
C2H4
HCl
C2H2
CL2
C2H3CL
C2H4CL2
H20
hydroquinone
beban vaporizer
panas reaktor
panas dipilih reaktor
panas hilang di QT 1
beban reboiler 1
beban kondenser 1
beban reboiler 2
beban kondenser 2
panas penyerapan HCl di absorber
beban HE 1
beban HE 2
panas hilang dari seluruh sistem
total
panas hilang =
Input (kg/j)
25804.1102
3948271.0003
78179.2369
59991.4272
15030237.1977
38423739.4423
224594.0531
0.0000
10794719.1750
-161514927.0000
159967073.3000
1303275.1425
1615.1109
-666869.8457
-238494.3861
-552869.6481
4272230.7440
71156569.0602
6.0039%
Output (Kg/j)
4954.0837
-1465761.6720
-8335.4141
6558970.7814
18982665.0639
42364257.0227
-713571.4533
0.0000
5943696.4380
-709051.4825
117886.4859
80859.2065
71156569.0602
1. Vaporizer
komponen
C2H4
HCl
C2H2
Cl2
C2H3Cl
C2H4Cl2
H2O
hydroquinone
subtotal
beban pemanas
total
input (Kj/j)
arus 8
0
0
0
0
0
1855739.5206
0
0
1855739.5206
-16349727.6462
18205467.1668
output (Kj/j)
arus 1
0
0
0
0
65673.8354
18139793.3314
0
0
18205467.1668
18205467.1668
2. Reaktor
komponen
C2H4
HCl
C2H2
Cl2
C2H3Cl
C2H4Cl2
H2O
hydroquinone
panas rx
subtotal
panas yang harus disuplai
total
input (Kj/j)
arus 3
0
0
0
0
65717.04843
7425833.349
0
0
-161514927
-154023376.6
159967073.3
5943696.697
output (Kj/j)
arus 4
712.1223966
-22391.66886
2431.599054
116.6175664
3450111.429
2512716.339
0
0
5943696.438
5943696.438
3. Quenching Tower
komponen
C2H4
HCl
C2H2
Cl2
C2H3Cl
C2H4Cl2
H2O
hydroquinone
input (Kj/j)
arus 4
712.1223966
-22391.66886
2431.599054
116.6175664
3450111.429
2512716.339
0
0
arus 6
0
0
0
0
0
-395325.8484
0
0
subtotal
5943696.438
5548370.59
panas hilang
total
-395325.8484
5548370.59
C2H4
HCl
C2H2
Cl2
C2H3Cl
C2H4Cl2
H2O
hydroquinone
subtotal
Q Reboiler
Q Condenser
total
Q input (Kj/j)
arus 5
326.9614
862202.1553
1882.598
263.3149
1717778.425
2997210.562
0
0
5579664.017
1303275.143
Q output (Kj/j)
arus 9
325.6963
854965.8003
1882.598
-6551895.669
-7618117.328
-7710048.271
0
-21022887.17
117886.4859
5697550.503
6882939.159
C2H4
HCl
C2H2
Cl2
C2H3Cl
C2H4Cl2
H2O
hydroquinone
subtotal
Q Reboiler
Q Condenser
total
Q input (Kj/j)
arus 13
1.2651
7236.355
0
6552158.984
9335895.753
10707258.83
0
Q output (Kj/j)
arus 14
output (Kj/j)
arus 5
326.9614
862202.1553
1882.598
263.3149
1717778.425
2997210.562
0
0
arus 7
0
0
0
0
0
1039059.353
0
0
5579664.017
6618723.37
-1070352.78
5548370.59
Q output (Kj/j)
arus 13
1.2651
7236.355
0
6552158.984
9335895.753
10707258.83
26602551.19
117886.4859
5697550.503
Q output (Kj/j)
arus 18
1039059.353