Jbptitbpp GDL Yennydelvi 22656 1 2010ta 1
Jbptitbpp GDL Yennydelvi 22656 1 2010ta 1
data by getting the mean value of relative permeability, and calculating the slope and intercept from relative
permeability versus water saturation plot. Graphic of water cut versus recovery factor is obtained by
substituting the slope and intercept of that plot, and substituting the initial water saturation data at the
perforating interval in the well.
From the results, it can be concluded that X-Plot method is valid to be used to determine water saturation If a
reservoir experiences a water drive mechanism either from injection wells or natural strong water drive and
produces water cut more than 50%. For getting the fractional flow curve that is representative, the X-Plot filter
is needed. Furthermore, we have successfully developed a suggested method for predicting water cut based on
X-Plot method from the SCAL data.
Keyword: water cut, special core analysis
* Mahasiswa Program Studi Teknik Perminyakan Institut Teknologi Bandung.
** Dosen Program Studi Teknik Perminyakan Institut Teknologi Bandung.
PENDAHULUAN
Ln
1
1
fw
1
fw .................................(1)
.....................................................(2)
Karena parameter X adalah fungsi parabolik
(Gambar 1), maka data yang digunakan hanya
untuk nilai fw lebih besar dari 50%.
0
-1
X-Function
I.
-2
-3
-4
-5
-6
0
0.2
0.4
0.6
0.8
1.2
fw, fraction
Er
mX
n ....................................................... (3)
1
m 1 Swi
................................................... (4)
exp
b n 1 S wi
S wi
............... (5)
Sw :
kro
krw
METODOLOGI
KERJA
a exp b S w
Prosedur menentukan Sw
Plot Er vs X
(WC>50%)
................................... (6)
Pembentukan
kurva kro/krw
1
k
1 ro
krw
fw
Penentuan m & n
(slope & intercept
kurva Er vs xplot) dengan
filterisasi
Penentuan
b&a(intercept &
slope kurva
kro/krw), input Swi
Sumuran
w
o
................................................. (7)
WC
PROSEDUR
fw
DAN
qw
qo
qw .......................................... (8)
Penentuan harga
fw
Pembentukan
kurva fw vs sw
Penentuan
persamaan fungsi
fw(sw)
Input data fw
Perata-rataan
kro,krw
Penentuan a & b
(intercept & slope
kurva kro/krw)
Plot WC Vs Er
Penentuan m & n
(slope & intercept
kurva Er vs x-plot)
dengan filterisasi
IV.
931137.1
Swi=
0.34
o (cp)=
4.59
w (cp)=
0.6732
Fungsi WC(Er)
0.450
0.400
Tanggal
Cum.Oil.Prod
(bbl)
WC
Er
8/1/1986
307326
0.696
-2.265
0.330
9/1/1986
310244
0.745
-2.414
0.333
10/1/1986
313568
0.696
-2.265
0.337
11/1/1986
314022
0.593
-2.062
0.337
12/1/1986
317289
0.620
-2.102
0.341
0.350
0.300
0.250
Er
0.200
0.150
0.100
1/1/1987
319247
0.832
-2.802
0.343
2/1/1987
320875
0.832
-2.802
0.345
3/1/1987
322852
0.832
-2.802
0.347
4/1/1987
325422
0.800
-2.636
0.349
5/1/1987
330235
0.660
-2.178
0.355
6/1/1987
334664
0.700
-2.276
0.359
7/1/1987
337357
0.753
-2.443
0.362
8/1/1987
339989
0.775
-2.527
0.365
9/1/1987
341872
0.811
-2.690
0.367
10/1/1987
343694
0.827
-2.774
0.369
11/1/1987
345608
0.820
-2.736
0.371
12/1/1987
347783
0.780
-2.548
0.374
1/1/1988
349556
0.840
-2.849
0.375
2/1/1988
351157
0.828
-2.779
0.377
3/1/1988
352365
0.859
-2.971
0.378
4/1/1988
352839
0.940
-3.815
0.379
5/1/1988
353665
0.920
-3.529
0.380
6/1/1988
354953
0.840
-2.849
0.381
7/1/1988
356400
0.861
-2.985
0.383
8/1/1988
358061
0.854
-2.937
0.385
9/1/1988
358857
0.930
-3.662
0.385
10/1/1988
359558
0.930
-3.662
0.386
11/1/1988
361575
0.791
-2.595
0.388
12/1/1988
362764
0.854
-2.937
0.390
1/1/1989
363934
0.842
-2.861
0.391
2/1/1989
365005
0.798
-2.627
0.392
3/1/1989
366439
0.798
-2.627
0.394
4/1/1989
367758
0.754
-2.446
0.395
5/1/1989
368871
0.750
-2.432
0.396
6/1/1989
370287
0.761
-2.472
0.398
7/1/1989
371356
0.880
-3.129
0.399
0.050
0.000
-5.000
-4.000
-3.000
-2.000
-1.000
0.000
X-Function
Gambar-5. X-Plot
1.2 Penentuan Slope (m) & Intercept (n) X-Plot.
X-Plot menampilkan kondisi tersebar, sehingga
memerlukan filterisasi untuk mendapatkan data
produksi yang lebih baik. Jika filterisasi tidak
dilakukan maka akan menghasilkan kurva
fractional flow kurang bagus dan tidak mewakili
kondisi reservoir sebenarnya. Hal tersebut dapat
dilihat dari bentuk kurva dan nilai Swi pada kurva
fractional flow yang tidak sesuai dengan data.
Dari trial and error yang telah penulis lakukan,
pemilihan data produksi dilakukan berdasarkan
nilai WC>50% yang paling mendekati dengan masa
sekarang, nilai Er maupun X harus kontinu, dan
simpangan yang diperbolehkan tidak melebihi
0.1%. Dengan 3 pertimbangan tersebut,
disimpulkan bahwa variabel m harus negatif dan n
harus positif.
Tabel-2. Data produksi Sumur-1 (filtered)
Tanggal
Cum.Oil.Prod
(bbl)
WC
Er
11/1/1986
314022
0.593
-2.062
0.337
12/1/1986
317289
0.620
-2.102
0.341
5/1/1987
330235
0.660
-2.178
0.355
6/1/1987
334664
0.700
-2.276
0.359
7/1/1987
337357
0.753
-2.443
0.362
8/1/1987
339989
0.775
-2.527
0.365
9/1/1987
341872
0.811
-2.690
0.367
11/1/1987
345608
0.820
-2.736
0.371
2/1/1988
351157
0.828
-2.779
0.377
6/1/1988
354953
0.840
-2.849
0.381
8/1/1988
358061
0.854
-2.937
0.385
7/1/1989
371356
0.880
-3.129
0.399
0.450
0.400
0.350
0.300
y = -0.049x + 0.240
R = 0.940
0.200
Er
0.250
0.150
0.100
0.050
0.000
-4.000
-3.000
-2.000
-1.000
0.000
1.2
X-Function
0.8
0.6
fw
0.4
0.2
0
-0.2
0.2
0.4
0.6
0.8
1.2
Sw
Gambar-8. Kurva fractional flow Sumur-1
Kurva fractional flow (Gmbr.8) menunjukkan nilai
Swi sebesar 0.34 yang sesuai dengan data log. Hal
ini menyatakan bahwa bentuk kurva bagus dan
representatif.
1.6 Penentuan Persamaan Fungsi fw(sw)
Penentuan persamaan fungsi fw(sw) merupakan
salah satu tahapan penting. Persamaan fungsi ini
ditentukan
dengan
menggunakan
program
matematis (Curve Expert).
10000000
kro/krw
1000000
10000
100
1
0.01
0.2
0.4
0.6
0.8
1.2
0.0001
0.000001
Sw
Gambar-7. Kurva kro/krw terhadap Sw
1.5 Kurva Fractional Flow
Setelah nilai kro/krw telah didapatkan, nilai fw dapat
dengan mudah dihitung sesuai persamaan
fractional flow yang diperkenalkan oleh BuckleyLaverett (Pers.7). Agar dapat menentukan nilai Sw
...........(9)
c = 29.368962
Sumur-2
...........(10)
0.700
0.600
0.500
Sw
Sumur-3
0.400
0.300
0.200
0.100
0.000
09/12/1985
09/12/1987
08/12/1989
Tanggal
08/12/1991
Gambar-11. Kurva
Richards) Sumur-3
fractional
flow
(Model
...........(11)
...........(12)
0.800
0.700
0.600
Sw
0.500
0.400
0.300
0.200
0.100
Sumur-3
0.000
09/12/1985
09/12/1987
08/12/1989
08/12/1991
Tanggal
Gambar-13. Grafik Sw Vs Waktu (Simulator)
2.3 Plot Sw Vs Waktu (X-Plot & Simulator)
0.7
0.6
0.5
Sw
0.4
0.700
Sw (Metode X-Plot)
0.3
0.600
Sw (Simulator)
0.2
0.500
0.1
Sw
0.400
Sw (Metode X-Plot)
0.300
Sw (Simulator)
0.200
0
01/06/1992
31/05/1996
30/05/2000
Tanggal
29/05/2004
28/05/2008
0.100
0.000
09/12/1985
09/12/1987
08/12/1989
08/12/1991
Tanggal
Gambar-14. Grafik Sw Vs Waktu (Sumur-1)
Secara umum, dapat dilihat bahwa Metode X-Plot
tergolong valid, karena merepresentasikan hasil
yang mendekati dengan data simulasi. Dari hasil
perhitungan, didapat penyimpangan secara rata-rata
sebesar 1.4 %.
Prosedur 5.2.1-5.2.3 diulang untuk Sumur-2 dan
sumur-3, didapat hasil seperti berikut.
Sumur-2
0.6
0.5
Sw
Sw (Metode X-Plot)
0.3
0.2
dengan
dengan
Data
0.7
0.4
Metode
X-Plot
tergolong
valid
penyimpangan rata-rata sebesar 1.86%.
Sw (Simulator)
0.1
0
09/12/1985 09/12/1987 08/12/1989 08/12/1991 07/12/1993 07/12/1995
Tanggal
1.00
0.90
0.80
0.70
0.60
3.4 Plot WC Vs Er
Plot WC terhadap Er menghasilkan persamaan
sebagai berikut: Er= -0.06464 X + 0 0.2142.
Kr*
0.50
0.40
0.30
Krw*
0.20
Kro*
0.10
0.00
0.00
0.20
0.40
0.60
Sw*
0.80
1.00
0.8
Kro
0.6
Kr
WC
Krw
0.8
0.6
0.4
0.4
0.2
0.2
0
0
-0.2
0
0
0.2
0.4
0.6
0.8
Sw
0.2
0.4
Er
0.6
0.8
Gambar-20. Grafik WC Vs Er
y = -9.742x + 5.296
R = 0.998
log (kro/krw)
1.5
1
0.5
0
-0.5
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
-1
-1.5
-2
Sw
Gambar-19. Kurva kro/krw (Data SCAL)
Penentuan variabel a dan b ditentukan dari
persamaan garis kurva kro/krw pada kordinat
semilog. Sesuai dengan perhitungan berdasarkan
Persamaan 6, nilai a sebesar 197696,964 dan b
sebesar -22.342.
3.3 Penentuan m dan n
Untuk dapat menentukan slope (m) dan intercept
(n) X-Plot dibutuhkan nilai Swi. Nilai Swi yang
dipakai berasal dari data log.
...........(13)
10
WC
0.800
fw
Sw
Swi
o
w
kro
krw
qo
qw
0.600
Data Produksi
0.400
VIII.
SCAL
Terima Kasih
0.200
0.000
0.300
0.350
0.400
0.450
0.500
Er
V.
1.
2.
3.
4.
KESIMPULAN
Metode X-Plot valid digunakan untuk
menentukan saturasi air.
Metode X-Plot berlaku untuk reservoir dengan
pendesakan air dari sumur injeksi maupun
strong water drive, telah berproduksi cukup
lama sehingga WC>50%.
Filterisasi X-Plot diperlukan untuk membentuk
kurva fractional flow sesuai dengan kondisi
reservoir sebenarnya.
Telah dihasilkan metode usulan berdasarkan
metode X-Plot untuk meramalkan nilai water
cut dari faktor perolehan minyak.
2.
VI.
SARAN
3.
4.
DAFTAR SIMBOL
RF
OOIP
EUR
WC
Er
11
Lampiran 1-Gambar Grafik X-Plot Terhadap Recovery Untuk Setiap Sumur Pada Lapangan X
0.500
0.400
0.300
Er
0.200
0.100
0.000
-5.000
-4.000
-3.000
-2.000
-1.000
0.000
X-Function
-6.0000
-4.0000
-2.0000
X-Function
Er
0.4500
0.4000
0.3500
0.3000
0.2500
0.2000
0.1500
0.1000
0.0500
0.0000
0.0000
0.450
0.400
0.350
0.300
0.250
0.200
0.150
0.100
0.050
0.000
-6.000
-4.000
-2.000
Er
0.000
X-Function
Gambar 1.3 Grafik X-Plot Terhadap Recovery Untuk Sumur-3
0.450
0.400
0.350
0.300
0.250
0.200
0.150
0.100
0.050
0.000
y = -0.049x + 0.240
R = 0.940
-4.000
-3.000
-2.000
X
-1.000
Er
0.000
0.450
0.400
0.350
0.300
0.250
0.200
0.150
0.100
0.050
0.000
y = -0.054x + 0.247
R = 0.936
-3.000
-2.000
-1.000
Er
0.000
X
Gambar 2.2 Grafik X-Plot (Filtered) Terhadap Recovery Untuk Sumur-2
0.400
0.350
0.300
0.250
0.200
0.150
0.100
0.050
0.000
y = -0.048x + 0.209
R = 0.966
-4.000
-3.000
-2.000
-1.000
0.000
log (kro/krw)
1000000
10000
100
1
0.01 0
0.5
1.5
0.0001
0.000001
Sw
log (kro/krw)
1000000
10000
100
1
0.01 0
0.5
1.5
0.0001
0.000001
Sw
10000000
100000
1000
10
0.1
0.5
1.5
0.001
0.00001
0.000000
Gambar3.3 Grafik Permeabilitas Relatif Terhadap Sw Untuk Sumur-3
Lampiran 4-Gambar Kurva Fractional Flow Terhadap Sw Berdasarkan Metode X-Plot Untuk Setiap Sumur
1.2
1
fw
0.8
0.6
0.4
0.2
0
-0.2 0
0.5
1.5
Sw
fw
0.4
0.2
0
-0.2 0
0.5
1.5
Sw
Gambar 4.2 Gambar Kurva Fractional Flow Terhadap Sw Untuk Sumur-2
1.2
1
fw
0.8
0.6
0.4
0.2
0
-0.2 0
0.5
1.5
Sw
Lampiran 5- Gambar Validasi Metode X-Plot Terhadap Data Simulasi Untuk Setiap Sumur
0.700
0.600
Sw
0.500
0.400
Sw (Metode X-Plot)
Sw (Simulator)
0.300
0.200
0.100
0.000
3/29/1986
8/11/1987
12/23/1988
5/7/1990
9/19/1991
Date
Gambar 5.1 Gambar Validasi Metode X-Plot Terhadap Data Simulasi Untuk Sumur-1
0.7
0.6
0.5
Sw
0.4
0.3
Sw (Metode X-Plot)
Sw (Simulator)
0.2
0.1
0
3/29/19868/11/198712/23/19885/7/1990 9/19/19911/31/19936/15/199410/28/1995
Tanggal
Gambar 5.2 Gambar Validasi Metode X-Plot Terhadap Data Simulasi Untuk Sumur-2
0.7
0.6
S-12
0.5
Sw
0.4
0.3
0.2
Sw (Metode X-Plot)
Sw (Simulator)
0.1
0
6/1/1992 2/26/1995 11/22/1997 8/18/2000 5/15/2003 2/8/2006 11/4/2008
Tanggal
Gambar 5.2 Gambar Validasi Metode X-Plot Terhadap Data Simulasi Untuk Sumur-3
Lampiran 6- Gambar Validasi Metode Peramalan Water Cut (Metode X-Plot) dari data SCAL Setiap Sumur
1.200
1.000
0.800
0.600
Prod
0.400
SCAL
0.200
0.000
0.300
0.320
0.340
0.360
0.380
0.400
0.420
0.440
0.460
Gambar 6.1 Gambar Validasi Metode Peramalan Water Cut (Metode X-Plot) dari data SCAL Sumur-1
1.2
1
WC
0.8
0.6
SCAL
Data Produksi
0.4
0.2
0
0.3
0.4
0.5
0.6
Er
0.7
0.8
0.9
Gambar 6.2 Gambar Validasi Metode Peramalan Water Cut (Metode X-Plot) dari data SCAL Sumur-2
1.200
1.000
0.800
WC
Data
SCAL
0.600
0.400
0.200
0.000
0.300
0.320
0.340
0.360
0.380
Er
0.400
0.420
0.440
0.460
Gambar 6.3 Gambar Validasi Metode Peramalan Water Cut (Metode X-Plot) dari data SCAL Sumur-3