DATA SHEET FOR SEPARATOR OF GRANULATOR GAS (DT511)
DOCUMENT NO:
0150-08-001
PROJECT NO .
0150
CONTRACT NO.
34-0150
PAGE 1 OF 4
o150-DS-00 1
Doc No .
12-Sep- 14
Date
DATA SHEET FOR
Sheet
Rev.
2 OF 4
1
GENERAL INFORMATION
1 Purchaser/ Agent
Site
FFBL
City
KARACH I
State
---
Zip Code
PAKISTAN
---
Phone
FFBL
2 User
3 Erection Site
FFBL
Location
4 Tank No.
DT-5 11
19
cu.m
Total Capacity
gpm
Out
95
Useful Co po city
In
6 Design Temp .
7 Product Stored
Design Metal Temperature
-950
Design Pressure
8 Corrosion Allowance
OOb ##
R. Vapor Pressure
gpm
1.50
At
---
95
---
C
psig
mmWC
Test Pressure
mm
Roof
mm
Bottom
mm
Struciurals
mm
API12 D
API12 D
0
11
cu.m
She ll
9 Shell Design
32
85 kpa
Yes 0
No
2B
Seismic Zone
SC
Soil Profi le
13 Wind Load
Importance Factor
160
Ve locity
Site Coefficient
14 Environmentol Effects
Maximum Rainfall
15 Size Restriction s
Maximum Diameter
16 Foundotion Type
17 Accessories
Earth
NOTES
1 As per site data & environmental data.
Yes
Yes .
No.
UBC Code
km/h
No.
in/Day
Nole-l ft
--3800
Steel Siructure
Maximum Height
mm
0
Other
2) Antigirating Device
See Sketch
mm
a150-D5-00 I
Doc No.
12-Sep-1 4
Date
DATA SHEET FOR
Sheet
3 OF 4
I
Rev.
CONSTRUCTION DETAILS
I Manufachxer
Site
BIN QASIM
City
KARACHI
State
Zip Code
Phone
State
Zip Code
Phone
Serial No.
2 Fabricator
Address
City
---
Serial No.
3 Material Specrlcatlons:
Structurels
4 No of SheH Courses
3 (THREE)
4)
7)
2)
5)
8)
3)
9)
6)
6 Tank Bottom
mm
CONICAL (NOTE-I )
-- To
--
Supported
Root Plate
Bult
Seams
Se lt-supported
Floaling
TYPE
II
Lap
Thickness
mm
- --
lap
Bult
Joint
12 Paint
She ll
Exterior?
Yes
No
m/sec
Interior?
DYes
No
Interior?
Yes
No
Interior?
Yes
No
Underside?
Yes
No
Surface Preparation
Structura l Sl eel
Exlerior?
Yes
No
Yes
No
Spec ification
13 Tank Bottom Coating
Underside?
Material
Shop
15 Weld Examination
Radiograph
Field
YES (JE = 0.85 and RT=Spol)
YES (IF APP LICABLE)
Property of
16 Films
17 Leak Testing
Bottom
Hydrostatic
Shell
Hydrost a tic
Required?
Plate
20 Tank Size
--
Yes
YES
Hydrostat ic
Roof
No
YES
01 50-DT-0511
Interna l Diamter
3 .8
m
l alest
He ig ht
2.773
Doc No .
4 OF 4
Sheet
Rev.
NOZZLE DATA
Description
Tag
A1
A2
A3
A4
SKETCH
Rating
150
14
150
150
11/4
150
A5
150
48
A6
150
A7
150
B1
150
16
B2
GAS OUTLET
150
NOTE 1
C1
SPARE
150
C2
SPARE
150
H1
MANHOLE
150
20
L1
OVER FLOW
150
M1
150
Q1
PRESSURE PO INT
3000
1/2
H2
MANHOLE
150
20
NOTES :
1
o150-DS-00 1
12-Sep -1 4
Date
, _____ ...
WELDING PROC_E.._~~E6PECIFICATION
No. .:::l
FFBIJ
_____
i
.. 1... .. _ _ _ _
.. _____
_.......______ ....______
Date of Issue
eft-1{1/1~ -J
Prepared By
SAA/N MQ
_ _ ~_
...
J9B:__ ':'Y~S for !~~Ei~~tion of_~~parator of Granulator Gas (Q!-l!.~ ) with ..?_~_~ 317 ~~~ D~PJ>la nt....__
Descri pt ion/ Specs/ Class
Ba se Metal
Weld To
SS-317L
SS-317L
Up to !Omm thk
Butt w el d/ fille~_~_~ 1d/ fillet plus groove weld
Th ickness
Joi nt Descri ptio n
JOINT PREPARATION :
'.i:
l."
i/) 'l
I,J
<
. 2-!>
20' ... 4
Preheating
N/A
ROOT PASS :
We ld Process
Fi ller Metal
Size (d iameter)
GTAW
------ -
. - - -- .......-..--....
ER-317L
1.6-2.4 mm
lOO"C
GTAW
'---_ _
ER
-317L
----......................-----........-.... ---1.6-2.4mm
--_._----_
..__.. _-----_._...........--- NA
Post Heating
Heat Treatment
Gas Backing
Inspection
NA
NA
_ ~es, after
Dye Check
Rad iograp hy
Rem arks:
r/l .___
proj:::~~~_:~eer.
.. ...
<
__
_
"
\'
I ns~ection ~:~i~~_e_r_:
.l
~~
__ ___
' \ .
_ _ __
/ ' -. . . . . .
\ >.
- :...
li(
II Notes :
1
'
(1) All F-llJX covered eiect rod('~ <;~ould be dfl(>d m suitable ollen en 150 ]50' C for a: leJs' Four Hour~ or 200-350 <' C (or fwo Hour s before U5e . (2)
_ Ocslcca:ms Should be used fo r Lo w Hydrogen E!ectroces (3 ) Weld joint snould oe ~ hi elded 'ron: AIr q!ac;to;/ WinCl, dun"'g and after we lding (4) Surfaces
to be welded should be c:lf.an from pew,t, oil, grea se. dust. d irt. debris, ru.s: etc. h) MI:'ximum Width Of we ld bead should not 'lC(Cp('j t hr(>r ti mc:!> wife 1
i
'I'
Cliameter (6) Only S.S gr in~ l ~g di s c~ 'ihOUld. be used fo r S5 we lding (I) Remove i:h.e Sl~g. tr.orough1 v af:cr .eaC..h
. . pass. {81 Ma!.n:a ln pr.ehedt tempE'fawrc
O;,,;f!ng w el ding. (9) Use sort flame Oxy propa nc or Oxymeth<:'ln(' for Pn:>heatlng/Post ncatmg (Dr O,l( v ace: ..,. ~('nf' Wltt't a >Ulti'lb!e w,d > nea;tng to rch)
...
. _
_..
..._....... ______...._.............
_ _ _ ...
_.. _ _ _ _ _
J'