Anda di halaman 1dari 4

Specifications

Brochure

AP-MCK-11

CEILING CASSETTE M5CK-E SERIES - R-410A


HEAT PUMP MODEL

INDOOR UNIT
OUTDOOR UNIT

NOMINAL COOLING CAPACITY


NOMINAL HEATING CAPACITY

50 Hz

NOMINAL TOTAL INPUT POWER


- 1 <3>
EER- 1 <3>
COP- 1 <3>

COOLING ONLY MODEL

COOLING
HEATING

INDOOR UNIT
OUTDOOR UNIT

NOMINAL CAPACITY

OUTDOOR UNIT

INDOOR UNIT

NOMINAL TOTAL INPUT POWER - 1 <3>


50 Hz
EER- 1 <3>
POWER SOURCE- 1 <3>
HIGH
MEDIUM
AIR FLOW
LOW
SUPER LOW
SOUND PRESSURE LEVEL (H/M/L/SL)
HEIGHT
UNIT DIMENSION
WIDTH
( ) - WITH PANEL
DEPTH
WEIGHT (UNIT + PANEL)
SOUND PRESSURE LEVEL
HEIGHT
WIDTH
UNIT DIMENSION
DEPTH
UNIT WEIGHT
TYPE
LIQUID
PIPE CONNECTION
SIZE
GAS

HEAT PUMP MODEL

NOMINAL HEATING CAPACITY


NOMINAL TOTAL INPUT POWER
- 1 <3>
EER- 1 <3>
COP- 1 <3>

COOLING ONLY MODEL

COOLING
HEATING

NOMINAL TOTAL INPUT POWER - 1 <3>


50 Hz
EER- 1 <3>
POWER SOURCE- 1 <3>
HIGH
MEDIUM
AIR FLOW
LOW
SUPER LOW
SOUND PRESSURE LEVEL (H/M/L/SL)
HEIGHT
UNIT DIMENSION
WIDTH
( ) - WITH PANEL
DEPTH
WEIGHT (UNIT + PANEL)
SOUND PRESSURE LEVEL
HEIGHT
UNIT DIMENSION
WIDTH
DEPTH
UNIT WEIGHT
TYPE
LIQUID
PIPE CONNECTION
SIZE
GAS

INDOOR UNIT

29 + 6 / 63.9 + 13.2
51
654 / 25.7
855 / 33.7
328 / 12.9
59 / 130.1

mm / in
mm / in

6.35 / 1/4
12.70 / 1/2

Btu/h
W
Btu/h
W
W
W
W/W
W/W

M5LC 035CR
29200 < 31000 >
8558 < 9086 >
31800 < 33400 >
9320 < 9789 >
2820 < 2770 >
2550 < 2550 >
3.03 < 3.28 >
3.66 < 3.84 >

M5CK 025ER
M5LC 025CR
22200
6506
20500
6008
1940
1760
3.36
3.41
M5CK 025E
M5LC 025C
22200
6506
1940
3.36
220 - 240 / 1 / 50
320 / 680
280 / 600
250 / 530
200 / 430
37 / 34 / 31 / 30
265 (340) / 10.4 (13.4)
820 (990) / 32.3 (39.0)
820 (990) / 32.3 (39.0)
29 + 6 / 63.9 + 13.2
52

280 / 600
250 / 530
200 / 430
190 / 400
34 / 31 / 28 / 27

62 / 136.7
FLARE VALVE
6.35 / 1/4
15.88 / 5/8

M5LC 040CR
39000 < 39000 >
11430 < 11430 >
39000 < 39500 >
11430 < 11577 >
3920 < 3840 >
3740 < 3610 >
2.92 < 2.98 >
3.06 < 3.21 >
M5CK 040E

Btu/h
W
W
W/W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm / in
mm / in
mm / in
kg / lb
dBA
mm / in
mm / in
mm / in
kg / lb
mm / in
mm / in

M5LC 035C
29200 < 31000 >
8558 < 9086 >
2820 < 2770 >
3.03 < 3.28 >

58

95 / 209.4
9.52 / 3/8
15.88 / 5/8

M5CK 028ER
M5LC 028CR
27000
7913
28000
8206
2790
2320
2.84
3.53
M5CK 028E
M5LC 028C
27000
7913
2790
2.84
410 / 860
340 / 725
290 / 620
250 / 530
41 / 38 / 35 / 32

29 + 6 / 63.9 + 13.2
54
756 / 29.8
855 / 33.7
328 / 12.9

M5CK 040ER

INDOOR UNIT
OUTDOOR UNIT

NOMINAL CAPACITY

OUTDOOR UNIT

Btu/h
W
W
W/W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm / in
mm / in
mm / in
kg / lb
dBA
mm / in
mm / in
mm / in
kg / lb

INDOOR UNIT
OUTDOOR UNIT

NOMINAL COOLING CAPACITY

50 Hz

Btu/h
W
Btu/h
W
W
W
W/W
W/W

M5CK 020ER
M5LC 020CR
18300
5363
17700
5188
1740
1490
3.08
3.48
M5CK 020E
M5LC 020C
18300
5363
1740
3.08

M5LC 040C
39000 < 39000 >
11430 < 11430 >
3920 < 3840 >
2.92 < 2.98 >
<380 - 415 / 3 / 50>
490 / 1030
410 / 860
350 / 740
295 / 620
44 / 41 / 38 / 36
300 (375) / 11.8 (14.8)
820 (990) / 32.3 (39.0)
820 (990) / 32.3 (39.0)
42 + 6 + / 92.6 + 13.2
58
852 / 33.5
1030 / 40.6
400 / 15.7
100 / 220.5
FLARE VALVE
9.52 / 3/8
15.88 / 5/8

68 / 150
9.52 / 3/8
15.88 / 5/8

M5CK 050ER
M5LC 050CR
< 43000 >
< 12603 >
< 47300 >
< 13863 >
< 4390 >
< 4010 >
< 2.87 >
< 3.46 >
M5CK 050E
M5LC 050C
< 43000 >
< 12603 >
< 4390 >
< 2.87 >

Ceiling Mounted
Cassette Unit

570 / 1200
490 / 1030
440 / 930
370 / 780
47 / 44 / 43 / 41

60

105 / 231.5
9.52 / 3/8
15.88 / 5/8

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
b) HEATING - 20C DB INDOOR AND 7C DB / 6C WB OUTDOOR
4) FOR A5CK 20/25 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA
FOR A5CK 28/40/50 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.

Products manufactured in an ISO certified facility.


This document contains the most current product information as of this printing.
For the most up-to-date product information, please go to www.mcquayup.com.

2011 McQuay International

www.mcquayup.com

A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.

Ceiling Mounted
Cassette Unit

It comes with 4 way air discharge


and air swing function to ensure
better air distribution and circulation
in the room.

Auto Mode

Auto Mode allows the setting to


change automatically between cool
and heat mode depending on the
room temperature and the set
temperature required.

Stylish And Slim Panel

The slim panel can be blended


easily into interior decoration and
design.

Hot Keep Cycle

During heat mode hot keep cycle,


the fan will run at low speed during
the thermostat cycle off. As a
result, one will not feel the draft of
cold air discharge from the unit.
Option of fan stop or fan run at
specific interval timing can also be
selected.

Ceiling Cassette

Self Diagnosis

C series

This intelligent feature helps to


detect any faults or malfunctioning
in the system and give user a
warning by blinking of the LED
lights.

MCK 010/015/020 C/CR

MLC 010/015 C/CR

Cooling:
9500 Btu/h - 19000 Btu/h
2.78 kW - 5.57 kW
Heating:
9500 Btu/h - 19500 Btu/h
2.78 kW - 5.72 kW

Built-In High
Drain Pump

Head

The unit comes with a built-in high


head drain pump 700mm head. A
safety float is incorporated in the
drain pump to monitor its water
level.

Choices Of Netware III Wired And Wireless Controller

4 Way Air Discharge


And Air Swing

GS01

NetWare III
Wired Controller
(Field Installed Optional
Accessories)

SLM 3
Wired Controller
(Field Installed Optional
Accessories)

NIM-Able

The MCK-C series is able to


communicate with the versatile
NIM networking control module
and offers the opportunity of one
centralized control for a systems
of multiple indoor units in a
building.
* Refer local representative for details.

Compact Design

The Ceiling Cassette C series is


designed to be compact. Its body
dimension is only 570mm X
570mm which can easily fit into a
600mm ceiling grids. This make
installation a lot easier.
Ceiling panel

700mm

T bar

MLC 018/020 C/CR


600 mm

Ceiling Cassette

E series

Modern And Elegant Panel

It is designed with unique round side contour and new LED


light location. Rotateable intake grill promote uniform
installation.
Allow 90 Rotation

Superior Sound Level


The MCK-E series is equipped with a newly-developed turbo fan;
the shape produce low air turbulence.
Indoor Model
MCK 020E/ER
MCK 025E/ER
MCK 028E/ER
MCK 040E/ER
MCK 050E/ER

Max (dBA)
34
37
41
44
47

Min (dBA)
27
30
32
36
41

With up to 4 selected fan speeds, users are given more choices.


By selecting the Quiet mode, the sound pressure level can be as
low as 27dBA.

Multi-Comfort - 3 Air Swing Pattern Control

To increase the comfort level of the air conditioned area of MCK-E series, the system had been built in with 3
different type of air flow pattern to suit different requirement.

35

35

MCK 020/025/028/
040/050 E/ER
Cooling:
19500 Btu/h - 47500 Btu/h
5.7 kW - 14.5 kW
Heating:
19500 Btu/h - 48000 Btu/h
5.7 kW - 14.7 kW

75

75

35

35
55

Standard Setting
For gentle drafts.

PATTERN 1

55
Draft Prevention Setting
Select this setting to eliminate direct
drafts which can lead to discomfort.

PATTERN 2

55

55

Setting to Prevent Soiling of Ceiling


Recommended for location with light
colour ceiling that must be kept potless.

PATTERN 3

The default setting for air swing pattern is pattern 1. The air swing pattern can be selected through the wireless remote control.

Lower Height Model

The MCK-E series height is as low as 290mm to ease


installation.

Dimension (mm)
Model
A
260
MCK 020 ~ 028E/ER
300
MCK 040 ~ 050E/ER

Optimum Air Discharge

Combining 4 ways air discharge and large discharge area


on each side, Ceiling Cassette promote even air
distribution. The additional of the automatic air swing help
further to evenly distribute conditioned air to every corner
of the instrall area.

75

75

Built-In High Head Drain Pump

The unit comes with a built-in high head drain pump 700mm
head. A safety float is incorporated in the drain pump to
monitor its water level.

700mm

B
290
325

NOMINAL TOTAL INPUT POWER

COOLING
HEATING

EER
COP

COOLING ONLY MODEL

INDOOR UNIT
OUTDOOR UNIT

50 Hz

NOMINAL CAPACITY

INDOOR UNIT

NOMINAL TOTAL INPUT POWER


EER
POWER SOURCE
AIR FLOW

HIGH
MEDIUM
LOW

SOUND PRESSURE LEVEL (H/M/L)


UNIT DIMENSION
( ) - WITH PANEL

HEIGHT
WIDTH
DEPTH

OUTDOOR UNIT

UNIT WEIGHT (UNIT + PANEL)


SOUND PRESSURE LEVEL
UNIT DIMENSION

HEIGHT
WIDTH
DEPTH

UNIT WEIGHT

Btu/h
W
W
W/W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
dBA
mm/in
mm/in
mm/in
kg/lb

TYPE
PIPE CONNECTION

SIZE

LIQUID
GAS

mm/in
mm/in

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
b) HEATING - 20C DB INDOOR AND 7C DB / 6C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.

INDOOR UNIT

MCK 020ER

MCK 025ER

MCK 028ER

OUTDOOR UNIT

MLC 020CR

MLC 025CR

MLC 028CR

Btu/h

19500

25000

27000

5715

7327

7913

Btu/h

19500

25000

28000

NOMINAL COOLING CAPACITY


NOMINAL HEATING CAPACITY

50 Hz

50 Hz

NOMINAL HEATING CAPACITY

Btu/h
W
Btu/h
W
W
W
W/W
W/W

HEAT PUMP MODEL

5715

7327

8206

COOLING

1960

2540

2720

HEATING

1690

2310

2350

EER- 1 <3>

W/W

2.91

2.89

2.91

COP- 1 <3>

W/W

3.38

3.17

3.50

MCK 020E

MCK 025E

MCK 028E

NOMINAL TOTAL INPUT POWER


- 1 <3>

INDOOR UNIT

COOLING ONLY MODEL

MLC 020C

MLC 025C

MLC 028C

Btu/h

19500

25000

27000

5715

7327

7913

1960

2540

2720

EER- 1 <3>

W/W

2.91

2.89

2.91

POWER SOURCE- 1 <3>

V/Ph/Hz

OUTDOOR UNIT

NOMINAL CAPACITY
50 Hz

NOMINAL COOLING CAPACITY

CEILING CASSETTE M5CK-E SERIES - R-22


MCK 020CR
MCK 015CR
MLC 015CR
MLC 018CR
MLC 020CR
12500
18000
19000
3660
5280
5570
12500
18400
19500
3660
5390
5720
1206
1840
1832
1056
1680
1782
3.03
2.87
3.04
3.47
3.21
3.21
MCK 015C
MCK 020C
MLC 015C
MLC 018C
MLC 020C
12500
18000
19000
3663
5280
5570
1231
1840
1832
2.98
2.87
3.04
220 - 240 / 1 / 50
212 / 450
194 / 410
194 / 410
194 / 410
170 / 360
170 / 360
160 / 340
156 / 330
146 / 310
44 / 41 / 37
41 / 38 / 35
41 / 38 / 34
250 (295) / 9.8 (11.6)
250 (295) / 9.8 (11.6)
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
23 + 2 / 50.7 + 4.4
22 + 2 / 48.5 + 4.4
23 + 2 / 50.7 + 4.4
46
49
51
51
540 / 21.3
654 / 25.7
700 / 27.6
855 / 33.7
250 / 9.8
328 / 12.9
32 / 70.5
32 / 70.5
58 / 127.9
59 / 130.1
FLARE VALVE
6.35 / 1/4
6.35 / 1/4
6.35 / 1/4
6.35 / 1/4
9.52 / 3/8
12.70 / 1/2
15.88 / 5/8
15.88 / 5/8
MCK 010CR
MLC 010CR
9500
2780
9500
2780
889
779
3.13
3.57
MCK 010C
MLC 010C
9500
2780
889
3.13

INDOOR UNIT

HEAT PUMP MODEL

INDOOR UNIT
OUTDOOR UNIT

OUTDOOR UNIT

CEILING CASSETTE M5CK-C SERIES - R-22

NOMINAL TOTAL INPUT POWER - 1 <3>

AIR FLOW

HIGH

l/s / CFM

280 / 600

320 / 680

410 / 860

MEDIUM

l/s / CFM

250 / 530

280 / 600

340 / 725

LOW

l/s / CFM

200 / 430

250 / 530

290 / 620

SUPER LOW

l/s / CFM

190 / 400

200 / 430

250 / 530

dBA

34 / 31 / 28 / 27

37 / 34 / 31 / 30

41 / 38 / 35 / 32

SOUND PRESSURE LEVEL (H/M/L)


UNIT DIMENSION
( ) - WITH PANEL

220 - 240 / 1 / 50

HEIGHT

mm/in

265 (340) / 10.4 (13.4)

WIDTH

mm/in

820 (990) / 32.3 (39.0)

DEPTH

mm/in

820 (990) / 32.3 (39.0)


29 + 6 / 63.9 + 13.2

UNIT WEIGHT

kg/lb

SOUND PRESSURE LEVEL

dBA

51

HEIGHT

mm/in

654 / 25.7

WIDTH

mm/in

855 / 33.7

855 / 33.7

DEPTH

mm/in

328 / 12.9

328 / 12.9

kg/lb

59 / 130.1

UNIT DIMENSION
UNIT WEIGHT

52

62 / 136.7

TYPE
PIPE CONNECTION

SIZE

54
756 / 29.8

68 / 149.9

FLARE VALVE
LIQUID

mm/in

6.35 / 1/4

9.52 / 3/8

9.52 / 3/8

GAS

mm/in

15.88 / 5/8

15.88 / 5/8

15.88 / 5/8

CEILING CASSETTE M5CK-C SERIES - R-410A


M5CK 015CR

M5CK 020CR

M5LC 010CR

M5LC 015CR

M5LC 020CR

Btu/h

9500

12500

17500 <18000>

2780

3660

5129 <5280>

Btu/h

9500

11500

17500 <18500>

2780

3370

5129 <5420>

COOLING

900

1300

1690 <1724>

HEATING

830

1020

1710 <1494>

EER - 1 <3>

W/W

3.09

2.82

3.03 <3.06>

COP - 1 <3>

W/W

3.35

3.30

3.00 <3.63>

50 Hz

NOMINAL HEATING CAPACITY - 1 <3>


NOMINAL TOTAL INPUT POWER
- 1 <3>

COOLING ONLY MODEL

INDOOR UNIT

M5CK 010C

M5CK 015C

M5CK 020C

OUTDOOR UNIT

M5LC 010C

M5LC 015C

M5LC 020C

50 Hz

NOMINAL CAPACITY - 1 <3>


NOMINAL TOTAL INPUT POWER - 1 <3>
EER - 1 <3>

POWER SOURCE - 1 <3>

OUTDOOR UNIT

INDOOR UNIT

AIR FLOW

9500

12500

17500 <18000>

2780

3660

5129 <5280>

900

1300

1690 <1724>

W/W

3.09

2.82

3.03 <3.06>

V/Ph/Hz
l/s / CFM

194 / 410

194 / 410

213 / 450

MEDIUM

l/s / CFM

170 / 360

170 / 360

194 / 410

LOW

l/s / CFM

156 / 330

147 / 310

161 / 340

dBA

41 / 38 / 35

41 / 38 / 34

44 / 41 / 37

HEIGHT

mm/in

250 (295) / 9.8 (11.6)

WIDTH

mm/in

570 (640) / 22.4 (25.2)

DEPTH

mm/in

570 (640) / 22.4 (25.2)

UNIT WEIGHT (UNIT + PANEL)

kg/lb

SOUND PRESSURE LEVEL

dBA

UNIT DIMENSION

HEIGHT
WIDTH
DEPTH

mm/in
mm/in
mm/in
kg/lb

UNIT WEIGHT

22 + 2 / 48.5 + 4.4
46

SIZE

LIQUID
GAS

mm/in
mm/in

23 + 2 / 50.7 + 4.4

49

52

540 / 21.3
700 / 27.6
250 / 9.8
31 / 72.75

TYPE
PIPE CONNECTION

23.2 / 50.7 + 4.4

6.35 /
9.52 /

35 / 77.16
FLARE VALVE
6.35 /
12.70 /

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
b) HEATING - 20C DB INDOOR AND 7C DB / 6C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.

654 / 25.7
855 / 33.7
328 / 12.9
59 / 130.1
6.35 /
12.70 /

MLC 040DR

MLC 050DR

Btu/h

35000

39500

48000

10258

11600

14100

Btu/h

35000

42000

50000

COOLING
HEATING

10258

12300

14700

3010

3600 <3500>

<4800>

2750

3250 <3200>

<4200>

EER- 1 <3>

W/W

3.41

3.22 <3.31>

<2.93>

COP- 1 <3>

W/W

3.73

3.79 <3.85>

COOLING ONLY MODEL

MCK 040E

INDOOR UNIT
OUTDOOR UNIT

NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER - 1 <3>

MLC 035D

MLC 040D

MLC 050D

35000

39500

49500

10258

11600

14500

3010

3506 <3650>

<4600>

3.30 <3.17>

<3.15>

EER- 1 <3>

W/W

3.41

V/Ph/Hz

220 - 240 / 1 / 50

AIR FLOW

l/s / CFM

490 / 1030

570 / 1200

MEDIUM

l/s / CFM

410 / 860

490 / 1030

LOW

l/s / CFM

350 / 740

440 / 930

SUPER LOW

l/s / CFM

295 / 620

370 / 780

dBA

44 / 41 / 38 / 35

47 / 44 / 43 / 39

HEIGHT

mm/in

300 (375) / 11.8 (14.8)

WIDTH

mm/in

820 (990) / 32.3 (39.0)

DEPTH

mm/in

820 (990) / 32.3 (39.0)

UNIT WEIGHT

kg/lb

SOUND PRESSURE LEVEL

dBA

UNIT DIMENSION

42 + 6 + / 92.6 + 13.2
58

58

HEIGHT

mm/in

852 / 33.5

WIDTH

mm/in

1030 / 40.6

DEPTH

mm/in

UNIT WEIGHT

kg/lb

SIZE

58

400 / 15.7
95 / 209.4

TYPE
PIPE CONNECTION

<380 - 415 / 3 / 50>

HIGH

SOUND PRESSURE LEVEL (H/M/L)


UNIT DIMENSION
( ) - WITH PANEL

<3.49>
MCK 050E

Btu/h

POWER SOURCE- 1 <3>

220-240/1/50 <380-415/3/50>

220 - 240 / 1 / 50

HIGH

SOUND PRESSURE LEVEL (H/M/L)


UNIT DIMENSION
( ) - WITH PANEL

Btu/h

NOMINAL TOTAL INPUT POWER


- 1 <3>

MLC 035DR

OUTDOOR UNIT

NOMINAL HEATING CAPACITY

MCK 050ER

MCK 040ER

INDOOR UNIT

NOMINAL COOLING CAPACITY

INDOOR UNIT

NOMINAL COOLING CAPACITY - 1 <3>

HEAT PUMP MODEL

50 Hz

M5CK 010CR

OUTDOOR UNIT

50 Hz

INDOOR UNIT

OUTDOOR UNIT

HEATPUMP MODEL

100 / 220.5

105 / 231.5

FLARE VALVE
LIQUID

mm/in

9.52 / 3/8

9.52 / 3/8

9.52 / 3/8

GAS

mm/in

19.05 / 3/4

19.05 / 3/4

19.05 / 3/4

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
b) HEATING - 20C DB INDOOR AND 7C DB / 6C WB OUTDOOR
4) I) FOR MCK 020/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.
II) FOR MCK 028/040/050 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.

Anda mungkin juga menyukai