Brochure
AP-MCK-11
INDOOR UNIT
OUTDOOR UNIT
50 Hz
COOLING
HEATING
INDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY
OUTDOOR UNIT
INDOOR UNIT
COOLING
HEATING
INDOOR UNIT
29 + 6 / 63.9 + 13.2
51
654 / 25.7
855 / 33.7
328 / 12.9
59 / 130.1
mm / in
mm / in
6.35 / 1/4
12.70 / 1/2
Btu/h
W
Btu/h
W
W
W
W/W
W/W
M5LC 035CR
29200 < 31000 >
8558 < 9086 >
31800 < 33400 >
9320 < 9789 >
2820 < 2770 >
2550 < 2550 >
3.03 < 3.28 >
3.66 < 3.84 >
M5CK 025ER
M5LC 025CR
22200
6506
20500
6008
1940
1760
3.36
3.41
M5CK 025E
M5LC 025C
22200
6506
1940
3.36
220 - 240 / 1 / 50
320 / 680
280 / 600
250 / 530
200 / 430
37 / 34 / 31 / 30
265 (340) / 10.4 (13.4)
820 (990) / 32.3 (39.0)
820 (990) / 32.3 (39.0)
29 + 6 / 63.9 + 13.2
52
280 / 600
250 / 530
200 / 430
190 / 400
34 / 31 / 28 / 27
62 / 136.7
FLARE VALVE
6.35 / 1/4
15.88 / 5/8
M5LC 040CR
39000 < 39000 >
11430 < 11430 >
39000 < 39500 >
11430 < 11577 >
3920 < 3840 >
3740 < 3610 >
2.92 < 2.98 >
3.06 < 3.21 >
M5CK 040E
Btu/h
W
W
W/W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm / in
mm / in
mm / in
kg / lb
dBA
mm / in
mm / in
mm / in
kg / lb
mm / in
mm / in
M5LC 035C
29200 < 31000 >
8558 < 9086 >
2820 < 2770 >
3.03 < 3.28 >
58
95 / 209.4
9.52 / 3/8
15.88 / 5/8
M5CK 028ER
M5LC 028CR
27000
7913
28000
8206
2790
2320
2.84
3.53
M5CK 028E
M5LC 028C
27000
7913
2790
2.84
410 / 860
340 / 725
290 / 620
250 / 530
41 / 38 / 35 / 32
29 + 6 / 63.9 + 13.2
54
756 / 29.8
855 / 33.7
328 / 12.9
M5CK 040ER
INDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY
OUTDOOR UNIT
Btu/h
W
W
W/W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm / in
mm / in
mm / in
kg / lb
dBA
mm / in
mm / in
mm / in
kg / lb
INDOOR UNIT
OUTDOOR UNIT
50 Hz
Btu/h
W
Btu/h
W
W
W
W/W
W/W
M5CK 020ER
M5LC 020CR
18300
5363
17700
5188
1740
1490
3.08
3.48
M5CK 020E
M5LC 020C
18300
5363
1740
3.08
M5LC 040C
39000 < 39000 >
11430 < 11430 >
3920 < 3840 >
2.92 < 2.98 >
<380 - 415 / 3 / 50>
490 / 1030
410 / 860
350 / 740
295 / 620
44 / 41 / 38 / 36
300 (375) / 11.8 (14.8)
820 (990) / 32.3 (39.0)
820 (990) / 32.3 (39.0)
42 + 6 + / 92.6 + 13.2
58
852 / 33.5
1030 / 40.6
400 / 15.7
100 / 220.5
FLARE VALVE
9.52 / 3/8
15.88 / 5/8
68 / 150
9.52 / 3/8
15.88 / 5/8
M5CK 050ER
M5LC 050CR
< 43000 >
< 12603 >
< 47300 >
< 13863 >
< 4390 >
< 4010 >
< 2.87 >
< 3.46 >
M5CK 050E
M5LC 050C
< 43000 >
< 12603 >
< 4390 >
< 2.87 >
Ceiling Mounted
Cassette Unit
570 / 1200
490 / 1030
440 / 930
370 / 780
47 / 44 / 43 / 41
60
105 / 231.5
9.52 / 3/8
15.88 / 5/8
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
b) HEATING - 20C DB INDOOR AND 7C DB / 6C WB OUTDOOR
4) FOR A5CK 20/25 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA
FOR A5CK 28/40/50 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.
www.mcquayup.com
A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.
Ceiling Mounted
Cassette Unit
Auto Mode
Ceiling Cassette
Self Diagnosis
C series
Cooling:
9500 Btu/h - 19000 Btu/h
2.78 kW - 5.57 kW
Heating:
9500 Btu/h - 19500 Btu/h
2.78 kW - 5.72 kW
Built-In High
Drain Pump
Head
GS01
NetWare III
Wired Controller
(Field Installed Optional
Accessories)
SLM 3
Wired Controller
(Field Installed Optional
Accessories)
NIM-Able
Compact Design
700mm
T bar
Ceiling Cassette
E series
Max (dBA)
34
37
41
44
47
Min (dBA)
27
30
32
36
41
To increase the comfort level of the air conditioned area of MCK-E series, the system had been built in with 3
different type of air flow pattern to suit different requirement.
35
35
MCK 020/025/028/
040/050 E/ER
Cooling:
19500 Btu/h - 47500 Btu/h
5.7 kW - 14.5 kW
Heating:
19500 Btu/h - 48000 Btu/h
5.7 kW - 14.7 kW
75
75
35
35
55
Standard Setting
For gentle drafts.
PATTERN 1
55
Draft Prevention Setting
Select this setting to eliminate direct
drafts which can lead to discomfort.
PATTERN 2
55
55
PATTERN 3
The default setting for air swing pattern is pattern 1. The air swing pattern can be selected through the wireless remote control.
Dimension (mm)
Model
A
260
MCK 020 ~ 028E/ER
300
MCK 040 ~ 050E/ER
75
75
The unit comes with a built-in high head drain pump 700mm
head. A safety float is incorporated in the drain pump to
monitor its water level.
700mm
B
290
325
COOLING
HEATING
EER
COP
INDOOR UNIT
OUTDOOR UNIT
50 Hz
NOMINAL CAPACITY
INDOOR UNIT
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
OUTDOOR UNIT
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
Btu/h
W
W
W/W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
dBA
mm/in
mm/in
mm/in
kg/lb
TYPE
PIPE CONNECTION
SIZE
LIQUID
GAS
mm/in
mm/in
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
b) HEATING - 20C DB INDOOR AND 7C DB / 6C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.
INDOOR UNIT
MCK 020ER
MCK 025ER
MCK 028ER
OUTDOOR UNIT
MLC 020CR
MLC 025CR
MLC 028CR
Btu/h
19500
25000
27000
5715
7327
7913
Btu/h
19500
25000
28000
50 Hz
50 Hz
Btu/h
W
Btu/h
W
W
W
W/W
W/W
5715
7327
8206
COOLING
1960
2540
2720
HEATING
1690
2310
2350
EER- 1 <3>
W/W
2.91
2.89
2.91
COP- 1 <3>
W/W
3.38
3.17
3.50
MCK 020E
MCK 025E
MCK 028E
INDOOR UNIT
MLC 020C
MLC 025C
MLC 028C
Btu/h
19500
25000
27000
5715
7327
7913
1960
2540
2720
EER- 1 <3>
W/W
2.91
2.89
2.91
V/Ph/Hz
OUTDOOR UNIT
NOMINAL CAPACITY
50 Hz
INDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
AIR FLOW
HIGH
l/s / CFM
280 / 600
320 / 680
410 / 860
MEDIUM
l/s / CFM
250 / 530
280 / 600
340 / 725
LOW
l/s / CFM
200 / 430
250 / 530
290 / 620
SUPER LOW
l/s / CFM
190 / 400
200 / 430
250 / 530
dBA
34 / 31 / 28 / 27
37 / 34 / 31 / 30
41 / 38 / 35 / 32
220 - 240 / 1 / 50
HEIGHT
mm/in
WIDTH
mm/in
DEPTH
mm/in
UNIT WEIGHT
kg/lb
dBA
51
HEIGHT
mm/in
654 / 25.7
WIDTH
mm/in
855 / 33.7
855 / 33.7
DEPTH
mm/in
328 / 12.9
328 / 12.9
kg/lb
59 / 130.1
UNIT DIMENSION
UNIT WEIGHT
52
62 / 136.7
TYPE
PIPE CONNECTION
SIZE
54
756 / 29.8
68 / 149.9
FLARE VALVE
LIQUID
mm/in
6.35 / 1/4
9.52 / 3/8
9.52 / 3/8
GAS
mm/in
15.88 / 5/8
15.88 / 5/8
15.88 / 5/8
M5CK 020CR
M5LC 010CR
M5LC 015CR
M5LC 020CR
Btu/h
9500
12500
17500 <18000>
2780
3660
5129 <5280>
Btu/h
9500
11500
17500 <18500>
2780
3370
5129 <5420>
COOLING
900
1300
1690 <1724>
HEATING
830
1020
1710 <1494>
EER - 1 <3>
W/W
3.09
2.82
3.03 <3.06>
COP - 1 <3>
W/W
3.35
3.30
3.00 <3.63>
50 Hz
INDOOR UNIT
M5CK 010C
M5CK 015C
M5CK 020C
OUTDOOR UNIT
M5LC 010C
M5LC 015C
M5LC 020C
50 Hz
OUTDOOR UNIT
INDOOR UNIT
AIR FLOW
9500
12500
17500 <18000>
2780
3660
5129 <5280>
900
1300
1690 <1724>
W/W
3.09
2.82
3.03 <3.06>
V/Ph/Hz
l/s / CFM
194 / 410
194 / 410
213 / 450
MEDIUM
l/s / CFM
170 / 360
170 / 360
194 / 410
LOW
l/s / CFM
156 / 330
147 / 310
161 / 340
dBA
41 / 38 / 35
41 / 38 / 34
44 / 41 / 37
HEIGHT
mm/in
WIDTH
mm/in
DEPTH
mm/in
kg/lb
dBA
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
mm/in
mm/in
mm/in
kg/lb
UNIT WEIGHT
22 + 2 / 48.5 + 4.4
46
SIZE
LIQUID
GAS
mm/in
mm/in
23 + 2 / 50.7 + 4.4
49
52
540 / 21.3
700 / 27.6
250 / 9.8
31 / 72.75
TYPE
PIPE CONNECTION
6.35 /
9.52 /
35 / 77.16
FLARE VALVE
6.35 /
12.70 /
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
b) HEATING - 20C DB INDOOR AND 7C DB / 6C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.
654 / 25.7
855 / 33.7
328 / 12.9
59 / 130.1
6.35 /
12.70 /
MLC 040DR
MLC 050DR
Btu/h
35000
39500
48000
10258
11600
14100
Btu/h
35000
42000
50000
COOLING
HEATING
10258
12300
14700
3010
3600 <3500>
<4800>
2750
3250 <3200>
<4200>
EER- 1 <3>
W/W
3.41
3.22 <3.31>
<2.93>
COP- 1 <3>
W/W
3.73
3.79 <3.85>
MCK 040E
INDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER - 1 <3>
MLC 035D
MLC 040D
MLC 050D
35000
39500
49500
10258
11600
14500
3010
3506 <3650>
<4600>
3.30 <3.17>
<3.15>
EER- 1 <3>
W/W
3.41
V/Ph/Hz
220 - 240 / 1 / 50
AIR FLOW
l/s / CFM
490 / 1030
570 / 1200
MEDIUM
l/s / CFM
410 / 860
490 / 1030
LOW
l/s / CFM
350 / 740
440 / 930
SUPER LOW
l/s / CFM
295 / 620
370 / 780
dBA
44 / 41 / 38 / 35
47 / 44 / 43 / 39
HEIGHT
mm/in
WIDTH
mm/in
DEPTH
mm/in
UNIT WEIGHT
kg/lb
dBA
UNIT DIMENSION
42 + 6 + / 92.6 + 13.2
58
58
HEIGHT
mm/in
852 / 33.5
WIDTH
mm/in
1030 / 40.6
DEPTH
mm/in
UNIT WEIGHT
kg/lb
SIZE
58
400 / 15.7
95 / 209.4
TYPE
PIPE CONNECTION
HIGH
<3.49>
MCK 050E
Btu/h
220-240/1/50 <380-415/3/50>
220 - 240 / 1 / 50
HIGH
Btu/h
MLC 035DR
OUTDOOR UNIT
MCK 050ER
MCK 040ER
INDOOR UNIT
INDOOR UNIT
50 Hz
M5CK 010CR
OUTDOOR UNIT
50 Hz
INDOOR UNIT
OUTDOOR UNIT
HEATPUMP MODEL
100 / 220.5
105 / 231.5
FLARE VALVE
LIQUID
mm/in
9.52 / 3/8
9.52 / 3/8
9.52 / 3/8
GAS
mm/in
19.05 / 3/4
19.05 / 3/4
19.05 / 3/4
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
b) HEATING - 20C DB INDOOR AND 7C DB / 6C WB OUTDOOR
4) I) FOR MCK 020/025 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.
II) FOR MCK 028/040/050 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.