D.C. P o w e r C o n t a c t o r s Ty p e 12 0
Sec.
STANCOR
Part
Number
Duty
Cycle
Type 120
Coil
Contact Rating-(Amps.)
Dimensions
Coil Resistance
Inductive Load
Inches
Terminal Pole Bracket Volt. (Ohms)
Contact Volt. Normally Open
Normally Closed
Case
Weight Agency
Type* Form Style D.C. @ 25C Material D.C. Continuous Inrush** Continuous Inrush L
W H (oz.) Certif.
A 120-901 Continuous
SPNO Standard
12
16.0
Silver Alloy 12
100
400
6.0
120-907 Continuous
SPNO
12
16.0
Silver Alloy 12
100
400
6.0
120-943 Continuous
SPNO
12
16.0
Silver Alloy 12
100
400
6.0
120-913 Continuous
SPNO Standard
12
16.0
Silver Alloy 12
100
400
6.0
B 120-906 Intermittent
SPNO Standard
12
6.0
80
400
6.0
120-912 Intermittent
SPNO
12
6.0
120-902 Continuous
SPNO Standard
15
20.8
120-908 Continuous
SPNO
15
20.8
L
L
Copper
12
Copper
12
80
400
6.0
Silver Alloy 15
100
400
6.0
Silver Alloy 15
100
400
6.0
120-903 Continuous
SPNO Standard
18
37.0
Silver Alloy 18
100
400
6.0
C 120-904 Continuous
SPNO Standard
24
64.0
Silver Alloy 24
100
400
6.0
120-910 Continuous
SPNO
24
64.0
Silver Alloy 24
100
400
6.0
120-905 Continuous
SPNO Standard
36
160.0
Silver Alloy 36
100
400
6.0
120-911 Continuous
SPNO
36
160.0
Silver Alloy 36
100
400
6.0
D 120-914 Continuous
SPNO Standard
15
23.0
Silver Nickel 15
100
400
6.0
SPNO
12
6.0
Silver Alloy 12
80
400
6.0
120L-915 Continuous
L
L
L
Water Resistant
Intermittent Duty Cycle = 30 seconds on maximum and 6 minutes off
* Terminal Type: 4 = Isolated Coil, 6 = Isolated Coil Automotive, 7 = Latching Contacts
** Inrush Current: Current applied within the first 1/2 second of contact closure
Engine e r i n g D e s i g n D a t a
Coil Rating
Nominal
Magnetic
D.C. Coil Rating
Type
(Watts)
Operation in % of Nom.
Breakdown Voltages
Coil Voltage Rating
All Terminals - 60 Hz RMS
Open
Max.
Contacts
Safe
Opposite
Same
To
Pick-up
Operate
Polarity
Polarity Ground
Contact Material
Power
Pilot
Electrical Life
Oper.
Oper. At
Per
Rated Load Min.
120
-
75%
110%
500
500
500
Copper
-
Silver Alloy
Temperature Range
10,000
50,000
2
2
Mechanical Life
Max.
Oper. Oper.
Oper. At
Per Temp.
No Load
Min
F
100,000
100,000
30
30
150
Note: Caution must be used in coil selection for use in 12 volt systems where battery charging may expose coil to continuous,
higher-than-rated voltage. Stancor will not be responsible for consequences of misapplied solenoids.
52
www.stancor.com
R E L AY S A N D C O N TA C T O R S
Type 12 0 & 120L
Te r m i n a l Ty p e 3 G r o u n d e d C o i l t o B r acket
L
2.125
1.062
H
3.253
2.125
.312 W
2.875
#10-32 UNF-2A
THREAD
.281 WIDE X .400 LONG
.451
(2 SLOTS) .495
MIN.
MIN.
3.094 MAX.
2.875
1.375
.250
1.375
.875
2.125
.388
MIN.
CIRCUIT
DIAGRAM
.875
Ter m i n a l Ty p e 4 I s o l a t e d C o i l ( L B r a c ket)
H MAX.
2.50
.900
L
3.25
CIRCUIT
DIAGRAM
2.125
5/16-24 UNF-2A
THREAD TYP.
.625 1.375
W 3.00
.048
2.500
WIDE .281 X
.400 LONG SLOT
#10-32 UNF-2A THD.
(2 PLACES)
.900
.625
.451
MIN.
.495 MIN.
3.137
MAX.
LABEL
2.125
1.375
3.00
.234
.875
CIRCUIT
DIAGRAM
.048
1.344
1.750
Te r m i n a l Ty p e 5
G r o u n d e d C o i l w i t h Q . C . Te r m i n a l
3.253 MAX.
.900
L
2.500
1.375
.312
4.000 .125
.220 MIN.
3.00
.495 MIN.
5/16-24 UNF-2A
THREAD TYP.
2.125
.875
.281 WIDE X .400 LONG
(4 SLOTS)
1.344
1.750
CIRCUIT
DIAGRAM
CIRCUIT
DIAGRAM
.875
5/16-24 UNF-2A THREAD
(2 PLACES)
www.stancor.com
53