JUDUL DOKUMEN
PRE-LIMINARY DESIGN
CATHODIC PROTECTION
03/05/2007
KH
REV
DATE
BY
DESKRIPSI
CHECK
APPR
APPR
TOTAL OR PARTIAL REPRODUCTION AND/OR UTILISATION OF THIS DOCUMENT ARE FORBIDDEN WITHOUT PRIOR WRITTEN AUTHORISATION
OF THE OWNER
DOCUMENT NO.
DS-001/ PR/KPDS/X/2014
REVISION
A
:
:
II PARAMETER DESAIN
Design Life (year)
Current Requirement (mA/m 2)
Coating Breakdown (%)
Safety Factor (%)
:
:
:
:
508 mm
54 Kg
20
20-30
5
25
: 125 - 150 Kg
:
0.8
:
2700
:
no
:
5m
nilai-nilai parameter diatas adalah nilai asumsi berdasarkan standards. Nilai sebenarnya dapat ditentukan berdasarkan
survey dan pengujian lapangan
00/01/1900
KH
REV
DATE
BY
DESKRIPSI
CHECK
APPR
APPR
TOTAL OR PARTIAL REPRODUCTION AND/OR UTILISATION OF THIS DOCUMENT ARE FORBIDDEN WITHOUT PRIOR WRITTEN
AUTHORISATION OF THE OWNER
0
PT KRAKATAU PRIMA DHARMA SENTANA
0
DOCUMENT NO.
DS-001/ PR/KPDS/X/2014
REVISION
A
PROJECT NAME
LOCATION
CLIENT / OWNER
CLIENT REFF.
Pipe Parameter
Pipe Diameter (m)
Pipe Length (m)
609
54
Design Parameter
Design Life (year)
Current Requirement (mA/m 2) (Bare)
Coating Breakdown (%)
Safety Factor (%)
Utility Factor (%)
Anode Capacity(AH/kg)
5
25
80
2700
Design Calculation
Anode Type
Anode Weight (Kg)
Anode Weight plus safety factor (Kg)
Number of Anode (Pcs)
20
20
Al
113
150
Environment Parameter
Soil Resistivity (ohm-cm)
Current Calculation
2
Area to be protected(m )
Current requirement (mA/m 2)
TOTAL CURRENT (Ampere)
Anode Size
Anode Weght (kg)
Size (with backfill)
Diameter (cm)
Length (cm)
950
20
1,15
150
Type
Aluminum Anode
Cast Aluminum
XLPE/PVC
CP Cable
25
00/01/1900
KH
REV
DATE
BY
DESKRIPSI
Qty
200
20
1000
CHECK
unit
Ket
APPR
APPR
unit
unit
e.a
m
TOTAL OR PARTIAL REPRODUCTION AND/OR UTILISATION OF THIS DOCUMENT ARE FORBIDDEN WITHOUT PRIOR WRITTEN
AUTHORISATION OF THE OWNER