Anda di halaman 1dari 19

GR2 Rack Capacity Guide

GR2 CAPACITY
Fiber Infrastructure System Technology

This document provides information on the FIST-GR2 capacity. It includes the following sections:
OVERVIEW GR2 CAPACITY
LAYOUT
GR2 CAPACITY NO SIDE DUCTS - 14 SUBRACKS - ETSI SYMMETRIC
GR2 CAPACITY NO SIDE DUCTS - 14 SUBRACKS - 19" SYMMETRIC
GR2 CAPACITY NO SIDE DUCTS - 14 SUBRACKS - 19" ASYMMETRIC
GR2 CAPACITY NO SIDE DUCTS - 13 SUBRACKS - 19"
GR2 CAPACITY 150 MM SIDE DUCTS - INTERCONNECT - OUT BOTTOM
GR2 CAPACITY 150 MM SIDE DUCTS - INTERCONNECT - OUT TOP
GR2 CAPACITY 150 MM SIDE DUCTS - CROSS CONNECT
GR2 CAPACITY 150 MM SIDE DUCTS - INTER & CROSS-CONNECT - OUT TOP
GR2 CAPACITY 150 MM SIDE DUCTS - DIRECT - 14 FIST-GPS2 SUBRACKS
GR2 CAPACITY 300 MM SIDE DUCTS - INTERCONNECT - OUT BOTTOM
GR2 CAPACITY 300 MM SIDE DUCTS - INTERCONNECT - OUT TOP
GR2 CAPACITY 300 MM SIDE DUCTS - CROSS-CONNECT
GR2 CAPACITY 300 MM SIDE DUCTS - INTER & CROSS-CONNECT - OUT TOP
GR2 CAPACITY 300 MM SIDE DUCTS - DIRECT
GR2 CAPACITY 300 MM SIDE DUCTS - VPS - OUT TOP
GR2 CAPACITY 300 MM SIDE DUCTS - VPS - OUT BOTTOM
Please consult your local sales engineer for applications not included in this document.

http://www.telecomosp.com
Issue 1.2 (04-01)

Page 1 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

OVERVIEW GR2 CAPACITY


NO SIDE DUCTS
SYM

ASYM 19

ETSI

19

narrow

wide

LAYOUT

Max. # of 2.4 mm pigtails (pcs)

288

504

Detailed information see page

SIDE DUCT 150 mm


ETSI shelves symmetric
LAYOUT
Max. # of 2.4 mm pigtails (pcs)

576

576

360

576

1008

10

11

(jumper)

Detailed information see page

SIDE DUCT 300 mm


ETSI shelves symmetric
LAYOUT
Max. # of 2.4 mm pigtails
(layout A,B,C,D,E: pcs
layout F and G: m)
Detailed information see page

1008

1008

504

1008

12

13

14

15

1008 1296 m 972 m

16

17

18

LAYOUT
A

IC out
bottom

IC out top

XC

IC + XC

direct

VPS
top out

VPS
bottom out

Issue 1.2 (04-01)

Page 2 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY NO SIDE DUCTS


14

SUBRACKS

ETSI SYMMETRIC

GR2CAP01
GR2CAP02.JPG

RESULTS
 Capacity:

 Limitations: See picture beside.

 Remarks:

72 pigtails diam. 2.4 mm.

GR2CAP03.JPG

Issue 1.2 (04-01)

Page 3 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY NO SIDE DUCTS


14

SUBRACKS

19 SYMMETRIC

GR2CAP04

GR2CAP05.JPG

RESULTS
 Capacity:

288 pigtails of diam. 2.4 mm

 Limitations:

 Remarks:

This amount of pigtails is allowed


because no handling is required.

GR2CAP06.JPG

Issue 1.2 (04-01)

Page 4 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY NO SIDE DUCTS


14

SUBRACKS

19 ASYMMETRIC

GR2CAP07
GR2CAP08.JPG

RESULTS
 Capacity:

504 pigtails of diam. 2.4 mm

 Limitations:

 Remarks:

This amount of pigtails is allowed


because no handling is required.

GR2CAP09.JPG

Issue 1.2 (04-01)

Page 5 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY FLEXTUBE NO SIDE DUCTS


13

SUBRACKS

19

GR2CAP12.JPG

GR2CAP10.JPG

GR2CAP11.JPG

GR2CAP13.JPG

RESULTS
 Capacity:

13 flextubes dia. 17 mm

 Limitations:

 Remarks:

GR2CAP14.JPG

Install PMA clip on side-panel of


subrack (see GR2CAP15.JPG).

GR2CAP15.JPG

Issue 1.2 (04-01)

Page 6 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 150 MM SIDE DUCTS


INTERCONNECT OUT BOTTOM
14

GR2CAP16

SUBRACKS

GR2CAP17

ETSI

GR2CAP18.JPG

RESULTS
 Capacity:

576 pigtails of diam. 2.4 mm

 Limitations:

 Remarks:

 Drum position in side duct left


(see GR2CAP17).
 The amount of pigtails can be
increased by 72 pcs when no
handling is required.
GR2CAP19.JPG

Issue 1.2 (04-01)

Page 7 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 150 MM SIDE DUCTS


INTERCONNECT OUT TOP
14

GR2CAP20

SUBRACKS

ETSI

GR2CAP21
GR2CAP22.JPG

RESULTS
 Capacity:

576 pigtails of diam. 2.4 mm

 Limitations: Top exit 150 mm side duct


filled with 576 pigtails (see
GR2CAP23.JPG).
 Remarks:

Drum position in side duct left


(see GR2CAP21).

GR2CAP23.JPG

Issue 1.2 (04-01)

Page 8 of 19

GR2CAP24.JPG

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 150 MM SIDE DUCTS


CROSS-CONNECT
14

GR2CAP25

SUBRACKS

ETSI

GR2CAP26

GR2CAP27.JPG3

RESULTS
 Capacity:

360 jumpers (720 pigtails) of diam. 2.4 mm.

 Limitations: 360 jumpers (720 pigtails between drum and


side plate (see GR2CAP28.JPG).

 Remarks:

Issue 1.2 (04-01)

All drums in side duct left, except drum at


position 37 or 53 (see GR2CAP26).
 For 1.8 m high GR2 use 4.5 m jumper length
and drum at position 38.
 For 2.2 and 2.6 m high GR2 use 5 m jumper
length and drum at position 53.

Page 9 of 19

GR2CAP28.JPG

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 150 MM SIDE DUCTS


INTER & CROSS-CONNECT OUT TOP
14

GR2CAP29

SUBRACKS

ETSI

GR2CAP30

GR2CAP31.JPG

RESULTS
 Capacity:

576 pigtails of diam. 2.4 mm


(depending on ratio between
inter- and cross-connect).

 Limitations:  576 pigtails through top exit


150 mm side duct
(see GR2CAP32.JPG).
 360 jumpers (720 pigtails)
between drum and side plate
(see GR2CAP33.JPG).
 Remarks:
All drums in side duct left,
except drum at position 53 in
side duct center (see GR2CAP30).
GR2CAP32.JPG

Issue 1.2 (04-01)

Page 10 of 19

GR2CAP33.JPG

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 150 MM SIDE DUCTS


DIRECT
14 FIST-GPS2

SUBRACKS

GR2CAP34

ETSI

GR2CAP35.JPG

RESULTS
 Capacity:

1008 pigtails of diam. 2.4 mm.

 Limitations: Base duct (see GR2CAP36.JPG and


GR2CAP37.JPG).

GR2CAP36.JPG

 Remarks:

GR2CAP37.JPG

Issue 1.2 (04-01)

Page 11 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 300 MM SIDE DUCTS


INTERCONNECT OUT BOTTOM
14

SUBRACKS

ETSI

GR2CAP38

GR2CAP39.JPG

GR2CAP40.JPG

RESULTS
 Capacity:

1008 pigtails of diam. 2.4 mm.

 Limitations: Base duct (see GR2CAP41.JPG).

 Remarks:

GR2CAP41.JPG

Issue 1.2 (04-01)

Page 12 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 300 MM SIDE DUCTS


INTERCONNECT OUT TOP
14

SUBRACKS

ETSI

GR2CAP42
GR2CAP43.JPG

GR2CAP44.JPG

RESULTS
 Capacity:

1008 pigtails of diam. 2.4 mm.

 Limitations: see GR2CAP45.JPG.

 Remarks:

GR2CAP45.JPG

Issue 1.2 (04-01)

Page 13 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 300 MM SIDE DUCTS


CROSS-CONNECT
14

SUBRACKS

ETSI

GR2CAP46

GR2CAP48.JPG

GR2CAP47.JPG

RESULTS
 Capacity:

504 jumpers (1008 pigtails) of diam. 2.4 mm.

 Limitations:

 Remarks:

Issue 1.2 (04-01)

Drum at position 37 or 53 moved to center of side duct


 For 1.8 m high GR2 use 4.5 m jumper length and
drum at position 38.
 For 2.2 and 2.6 m high GR2 use 5 m jumper length
and drum at position 53.

Page 14 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 300 MM SIDE DUCTS


INTER & CROSS-CONNECT OUT TOP
14

SUBRACKS

ETSI

GR2CAP49

GR2CAP50.JPG

GR2CAP51.JPG

RESULTS
 Capacity:

504 jumpers (1008 pigtails) of diam. 2.4 mm.

 Limitations: Drum at position 53 (see GR2CAP51.JPG).

 Remarks:

Issue 1.2 (04-01)

Drum at position 53 moved to center of side duct.

Page 15 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 300 MM SIDE DUCTS


DIRECT
14

SUBRACKS

ETSI

GR2CAP54.JPG

GR2CAP52
GR2CAP53.JPG

RESULTS
 Capacity:

1008 pigtails of diam. 2.4 mm.

 Limitations: Base duct (see GR2CAP55.JPG).

GR2CAP55.JPG

 Remarks:

Issue 1.2 (04-01)

Page 16 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 300 MM SIDE DUCTS


VPS OUT TOP
14

SUBRACKS

ETSI

GR2CAP58.JPG

GR2CAP56

GR2CAP57.JPG

RESULTS
 Capacity:

Capacity VPS =
360 x 4 x 90 cm = 1296 m.

 Limitations: See GR2CAP58.JPG..

 Remarks:

Issue 1.2 (04-01)

Page 17 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2 CAPACITY 300 MM SIDE DUCTS


VPS OUT BOTTOM
14

SUBRACKS

ETSI

GR2CAP61.JPG
GR2CAP59

GR2CAP60.JPG

RESULTS
 Capacity:

Capacity VPS =
360 x 3 x 90 cm = 972 m.

 Limitations: See GR2CAP61.JPG.

 Remarks:

Issue 1.2 (04-01)

Page 18 of 19

Product Manager: L.Vleugels

GR2 Rack Capacity Guide

GR2-CAPACITY.DOC
Tyco, Raychem and FOSC are trademarks.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes
only, is believed to be reliable. However, Tyco Electronics makes no warranties as to its accuracy or completeness and
disclaims any liability in connection with its use. Tyco Electronics obligations shall only be as set forth in Tyco Electronics
Standard Terms and Conditions of Sale of this product and in no case will Tyco Electronics be liable for any incidental,
indirect or consequential damages arising out of the sale, resale, use or misuse of the product.
Users of Tyco Electronics products should make their own evaluation to determine the suitability of each such product for
the specific application.
Copyright Tyco Electronics 2001
www.tycoelectronics.com

Issue 1.2 (04-01)

Page 19 of 19

Product Manager: L.Vleugels

Anda mungkin juga menyukai