Anda di halaman 1dari 3

UNIT:04

S.N.

Description
1 Unit Load
2 Condenser vacuum
3 CW inlet temp(L&R)
4 CW outlet temp(L&R)
5 Hot well temp
6 CW discharge pressure
7 CW pressure at condenser inlet
8 CW pressure at condenser outlet
9 Condenser air suction temp.
10 No. of ejecter in service
11 Ejectors steam pressure
12 Ejectors steam temp.
13 No. of CT Fan in service
14 Passing high energy drain v/v with temp.
15 Turbine gland steam temp/pressure
16 Any other observations

CONDENSER VACUUM STUDY


Unit
MW
mm of Hg
C
C
C
Kg/cm
Kg/cm
Kg/cm
C

Design
160
693.26
34
39.88
43.32

Kg/cm
C

7.7
200

No./C
C/Kg/cm

R VACUUM STUDY
Actual Value
121
680
36.5
41/40.5
46.2/46.1
2.0/1.95/1.9
2.1/2.0
1.65/1.6
40/45
2
6.4/6.6
210
7
180/0.2

Dt:

Anda mungkin juga menyukai