THE LINE UP BOILER FEED

WATER SYSTEM

LINE UP BOILER FEED WATER SYSTEM


Close boiler feed pump discharge valves.

Close boiler feed pump, discharge valves, bypass valves.

Close boiler feed pump discharge header drain valve.

Close feed water isolating valve.

Open feed line vent valve.

Open feed line drain valves.

Close HP heater FW inlet valve.

Close HP heater FW outlet valve.

Close HP heater FW bypass valve.

Close SH & RH attemperator header isolating valve.

Close RH spray block isolating valve.

Close SH attemperator Control valve inlet isolating valves.

Close RH attemperator or control valves inlet isolating valves.

Open feed line vent valve.

Close main feed control valve.

Close isolating valves.

Close stand by feed control valve and isolating valves.

Close bypass valves of standby control valves isolating valves.

Close bypass valves of isolating valves of low load control valves.

Open feed control station drain valves.

Close boiler filling isolating valves from boiler fill pumps.

Close hydrazine sampling valves before economizer.

Close economizer drain valve to water wall header.

LINE UP BOILER WATER & STEAM SYSTEM


Economizer

Open economizer recirculation valves.

Close economizer drain valves.

Open economizer outlet lines vent valves.

Close economizer outlet lines drain valves.

Drum

Open drum vent valves.

Close CBD isolating valve.

Close phosphate dosing isolating valves.

Check IBD valves are closed.

Open drum level gauge glass isolating valves quick closing valves.

Close drum level gauge glass drain valves.

Open isolating valves for local pressure gauge, level and pressure transducers.

Open isolating valves for remote drum level indicator.

Close remote level indicator gauge glass drain valves.

Open saturated steam sampling line valves.

Check that drum safety valves are in service condition.

Reheater

Open reheater feeders vent valves.

Open HRS header motorized vent valves.

Close sampling line valve.

Check that RH header safety valve are in service.

Open RH desuperheater left & right drain valves.

Close RH spray line drain valve & after spray control valves.

Close RH spray line drain valve & after spray control valves.

CBD Tank

Open isolating valves of main CBD control valve.

Close CBD control valve.

Close isolating & control valves of standby line.

Open CBD tank atmospheric vent valve.

Check CBD tank safety valve is in service.