 Pasolink is Point to Point DMW transmission system

Coaxial cable

Radio link

MUX MUX

Satellite

Fiber-optics cable

Xi’an NEC Pasolink Introduction


Application for Mobile Network
.....
3000S
MSC

BTS
BTS
BTS
BTS BTS BTS
BTS BTS
BTS PASOLINK
BTS BTS
BTS BTS
PSTN MSC PASO+
BSC PASO+ BTS
BSC BTS
BTS PASO+ BTS
BTS BSC
MSC : Mobile switching center BTS PASO+
BSC : Base station controller BTS BTS BSC
BTS : Base transceiver station BTS BTS
BTS BTS
BTS BTS BTS
BTS
BTS
BTS BTS
PASOLINK PASOLINK
BTS BTS
BTS BTS

Xi’an NEC Pasolink Introduction


Application for Cellular Network

Xi’an NEC Pasolink Introduction


Application for Cellular Network

Xi’an NEC Pasolink Introduction


Ethernet Application (1)

Xi’an NEC Pasolink Introduction


Ethernet Application (2)

Xi’an NEC Pasolink Introduction


Ethernet Application (3)

Xi’an NEC Pasolink Introduction


General Introduction

 A narrow band MW relay system, is easy to install, offers


system flexibility and is a field proven to be very reliable.
 Covered frequency: 7/8/13/15/18/23/26/38GHz.
 Transmission capacity: 2/4/8/16×2MB or with two 10
Base-T/100Base-TX plus additional service channels.
 1+0 Unprotected/1+1 Protected system

Xi’an NEC Pasolink Introduction


Feature(1)
 ADVANCED TECHNOLOGIES AND SUPERB PERFORMANCE
• MMIC, HIC AND VLSI
• Single chip modulator/ demodulator (Full digital)
• Square-root Nyquist Roll shaping filter
• High reliability
• Low power consumption
• Additional Main Interface 10 Base-T/100 Base-TX (Option)
 HIGH SYSYTEM GAIN
• QPSK Technology
• High performance LNA-MIX ( Superior receiver sensitivity)
• Allows small antennas and reducing system cost
 FREQUENCY AGILITY AND EASY TUNING
• Frequency tunable without changing RF filter on sub-band basis
• Field tunable local oscillators (Synthesizer)
• Sub-band changing by simply replacing filter

Xi’an NEC Pasolink Introduction


Feature(2)

 CONFORMITY WITH ANSI, ITU-U, ITU-T AND ETSI STANDARDS)

 EASY AND QUIK INSTALLATION


• Very compact and light
• Only one coaxial cable interconnection
• Automatic cable equalization
• Different mounting methods for IDU, ODU and Antenna
• Easy antenna pointing adjustments (RX level monitor point in ODU)

 TX POWER CONTROL
• Automatic Transmit Power Control (ATPC) or Manual Transmit Power
Control (MTPC)
• Variable : 0 to 30dB , in 1 dB steps(13-38GHz) (For V4 ODU 7-38GHz)
0 to 10dB, in 1dB steps(7-8GHz) (V3 ODU)
• Fixed : 10 to 20dB Fixed attenuator can be attached to the 7-8 GHz
output port.

Xi’an NEC Pasolink Introduction


Feature(3)
 SYSTEM FLEXIBILITY
• (1+0) Unprotected or (1+1) protected
• Hot Standby/Space Diversity/Twin Path system are available with Hitless
switch
• Common IDU for different RF frequencies(7/8/13/15/18/23/26/38GHz)
• Software variable transmission bit rates (Bit Rate free type)
• Common ODU for different bit rates( 16х2, 8х2, 4х2, 2х2Mbit/s/10Base-
T/100Base-TX)
• Wide input line voltage ± ( 20 to 60 ) V DC
 EASY MAINTENCE FACILITIES
• Full front panel access for all cabling and user interface
• Near End and Far End Base-band Loop back facilities
• Remote monitoring of ODU operating condition from IDU
• OW calling facility between IDU-ODU, IDU-IDU, and ODU-ODU
• Pre-settable BER alarm point : 10-3, 10-4, 10-5 or 10-6 ( alarm and AIS
injection)
• Local monitor and maintenance using Local Craft Terminal (LCT)
• Continuous RSL monitoring using Local Craft Terminal (LCT)

Xi’an NEC Pasolink Introduction


Feature(4)

 MULTIPLE SERVICE CHANNELS


• Engineering Order Wire (OW)
• Digital Service Channels-Two standard and two optional
• Analog Service Channels-Two optional
• NMS Service Channel for Pasolink Monitoring
• WS or SC LAN

 ELECTRO MAGNETIC COMPATIBILITY (EMC)


• Complies with ETS 300385

 PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) (OPTION)


• User friendly operation as maintenance terminal
• Link oriented monitor and control
• Uses Windows XP/2000/98 with mobile PC

Xi’an NEC Pasolink Introduction


Feature(5)

 PASOLINK NETWORK MANAGEMENT SYSTEM (PNMS) (OPTION)


• User friendly operation
• Uses Windows XP/2000/NT to ensure easy operation and
maintainability
• Remote access and control of any PASOLINK Terminal in the network
• Link oriented monitor and control ( both sides of a microwave link)
• Multi level security
• Event Logging
• ITU-T G.826 Performance Monitor( Table/graph presentation)
• SNMP Interface (Option)
• Real-time monitor of Network Elements (NE)

Xi’an NEC Pasolink Introduction


Introduction---IDU(1+0)

•2MB x 4, Fixed Bit Rate system

•2MB x 4, Fixed Bit Rate system with 2 x 10/1 00Base T (X) LAN Interface

Xi’an NEC Pasolink Introduction


Introduction---IDU(1+0)

•2MB x 2/4/8/16 Bit Rate Free system

•2MB x 2/4/8/16 Bit Rate Free system with 2 x 10/100Base T (X) LAN Interface

Note: IDUs with 75ohm BNC interface are also available


(2Mx4 and 2Mx8 fixed rate)

Xi’an NEC Pasolink Introduction


Introduction---IDU(1+1)

Front view 1+1 IDU 3U 4х 2MB fix rate

Front view 1+1 IDU 3U with LAN interface 4х 2MB fix rate
Note:1. IDUs with 75ohm BNC interface are also available (2Mx4 and 2Mx8
fixed rate)
2.The SC LAN port is actually WS/SC LAN port

Xi’an NEC Pasolink Introduction


Introduction---IDU

Front view 1+1 IDU 3U nх 2MB free rate (n=2/4/8/16)

Front view 1+0 IDU 1U with LAN interface nх 2MB free rate
(n=2/4/8/16)

Xi’an NEC Pasolink Introduction


I/O Board

D-sub-BNC Interface conversion panel (I/O Board)


16 x 2 MB

Xi’an NEC Pasolink Introduction


Introduction--Protection system

Hot standby system

Hot standby and space diversity

Xi’an NEC Pasolink Introduction


Introduction--Protection system

Twin Path system

Xi’an NEC Pasolink Introduction


Introduction-- ODU

IF connector to IDU RX LEV MON


RF interface to Antenna

Rear Side Front Side

Xi’an NEC Pasolink Introduction


V4 OUT DOOR UNIT- (7-38 GHz)

Xi’an NEC Pasolink Introduction


V4 ODU OUTLINE

Xi’an NEC Pasolink Introduction


V4 ODU OUTLINE

Xi’an NEC Pasolink Introduction


ODU Mounting Configuration

Flexible
waveguide

ODU bracket
with Waveguide
ODU
Adapt

13-38 GHz Remote Mounting of 7/8 GHz Remote Mounting of


1+0 PASOLINK ODU 1+0 PASOLINK ODU
Note:7/8 GHz ODU has Waveguide Interface
as Option

Xi’an NEC Pasolink Introduction


ODU Mounting Configuration

13 - 38 GHz Mounting of the 1+1 PASOLINK


ODU (One Antenna with Hybrid Combiner
unit)

13 - 38 GHz Mounting of the 1+1


PASOLINK ODU (Two Antennas)

Xi’an NEC Pasolink Introduction


ODU Mounting Configuration

13-38 GHz Remote Mounting of 1+1


PASOLINK ODU
13-38 GHz Remote Mounting of 1+1
PASOLINK ODU with two antennas

Xi’an NEC Pasolink Introduction


ODU Mounting Configuration

7/8GHz Hybrid Combiner of


7/8 GHz Mounting of 1+1 PASOLINK ODU the 1+1 PASOLINK System
with Hybrid Combiner and one antenna

Xi’an NEC Pasolink Introduction


ODU Mounting Configuration

13-38 GHz Direct Mount Dual Pole


7/8 GHz Mounting of 1+1 PASOLINK System
ODU with two antennas

Xi’an NEC Pasolink Introduction


ODU Mounting Configuration

Flexible
Wavegu
ide

ODU Pole Mount Bracket


with Waveguide Adapter
7/8 GHz Remote Mount Dual
Pole System
13-38 GHz Remote Mount Dual
Pole System

Xi’an NEC Pasolink Introduction


ODU Mounting Configuration

 Direct Mounting on Antenna

 Remote Mounting with Waveguide or Coaxial


Cable

 1+1 system with Hybrid Combiner / Divider

 2+0 system with Dual Polarization Antenna

Xi’an NEC Pasolink Introduction


V4 IDU

1+0 (NON PROTECTION) 1+1 (Protection) IDU

Xi’an NEC Pasolink Introduction


PASOLINK V4 IDU (1/3)
2 3 4 5 6 7
1 8

1. IF connector (to ODU)


2. 2Mbps interface (CH 9 to CH 16): impedance selector switch (75 or 120 ohms)
3. LAN Interface for main traffic: Port 1 and Port 2 (Optional)

4. WS/LAN: optional port for Wayside In/Out or 10BaseT


5. NMS LAN: for PNMS with LAN interface
6. Engineer’s Orderwire (EOW): receptacle for EOW headset

7. CALL: call buzzer for calling the opposite site of the transmission path

8. RESET: CPU reset switch for IDU

Xi’an NEC Pasolink Introduction


PASOLINK V4 IDU (2/3)

10 11 12 13
9
9. LED:
PWR : that the power switch is on (Green)
MAINT: for the purpose of maintenance (Yellow)
ODU : that the ODU alarms occur (Red)
IDU : that the IDU alarms occur (Red)
10. FG : connecting Frame Ground terminal
11. ESD: Connecting terminal for Electro Static Discharge

12. 2Mbps interface (CH 1 to CH 8) ): impedance selector switch (75 or 120 ohms)
13. ALM/AUX ALM: connector for parallel alarms (relay contact)
connector for Data Input / Data Output
Xi’an NEC Pasolink Introduction
PASOLINK V4 IDU (3/3)

14 15 16 17 18 19
14. OW / DSC / ASC
(1) Order wire
(2) Digital and Analog (VF) service channel

15. NMS / RA: for PNMS or remote access Local Craft Terminal (None PM Card)

16. LA Port: connector to PC for local access Local Craft Terminal or PNMT

17. Fuse: for primary DC line (be inserted in each plus and minus line)

18. 20SW : power switch

19. DC IN: connector for DC power in.

Xi’an NEC Pasolink Introduction


V4 IDU(1+1)

6 7 8 9

1 2 3 4 5

1. OPR SEL No.1-AUTO-No.2 switch: Enables channel switching depending on the


setting position in maintenance conditions.

2,3,4,5,6,7,8,9: OPR/ALM LEDs indicators

Xi’an NEC Pasolink Introduction


Theory of Operation(1)

Three Main sub-systems the Indoor Unit (IDU), the


Outdoor Unit (ODU) and the Antenna

System block diagram

Xi’an NEC Pasolink Introduction


Theory of Operation(2)

Basic block diagram of IDU

Xi’an NEC Pasolink Introduction


Theory of Operation(3)

IDU 1+0 block diagram

Xi’an NEC Pasolink Introduction


Theory of Operation(4)

Xi’an NEC Pasolink Introduction


Performance(1)

Xi’an NEC Pasolink Introduction


Performance(2)

Xi’an NEC Pasolink Introduction


Performance(3)

Xi’an NEC Pasolink Introduction


Performance(4)

Xi’an NEC Pasolink Introduction


Performance(5)

Xi’an NEC Pasolink Introduction


Performance (6)

Xi’an NEC Pasolink Introduction


Interconnection ( ODU and IDU)

Xi’an NEC Pasolink Introduction


Service Channels

Pasolink V4 uses six service channels in its radio overhead fram

Service Channels can be connected back-to-back at repeater station

Xi’an NEC Pasolink Introduction


V4 IDU Options
• SC LAN INTERFACE: 10 BASE-T (TRANSMISSION RATE 64Kbps)
• WS INTERFACE (G703): 2.048 Mbps G.703
• WS INTERFACE (LAN): 10 BASE-T (TRANSMISSION Rate 2 Mbps)
• ALM INTERFACE : 2 CH EXTERNAL DRY CONTACT EXTENSION
• ASC INTERFACE: 2 CH 0.3-3.4 KHz VOICE FREQUENCY
TRANSMISSION
• DSC INTERFACE: 2 CH 9.6 Kbps RS-232C OR RS-422 SELECTABLE
• 64K INTERFACE (G.703): 1 CH 64 Kbps TRANSMISSION
• 64K INTERFACE (V11): 1 CH 64 Kbps TRANSMISSION
• PM CARD(RS-232C): PNMS INTERFACE CARD WITH RS-232C FOR PC
• PM CARD(LAN): PNMS INTERFACE CARD WITH 10BASE-T FOR PC
Note:
• Optional cards cannot be changed without interrupting the main traffic.
• When SC LAN option card is mounted, it is not possible to mount ASC,
DSC, ALM and WS interface cards. 64k option card is available with
either G.703 or V11 interface
• PM card is available with either RS-232C or LAN interface

Xi’an NEC Pasolink Introduction


Option cards

Xi’an NEC Pasolink Introduction


IDU Interfaces (1)
 NEC PASOLINK SYSTEM HAS THE FOLLOWING ITU-T STANDARD
INTERFACES DIGITAL SIGNAL INTERFACES

• Signal Rate Fix Rate : 4x2 Mbp/s and 2x10/100BaseT(X)


• Rate Free : 2/4/8/16 x 2 Mbit/s and 2x10/100BaseT(X)
• Interface HDB-3 (ITU-T G.703)
• Impedance 75 Ohms / 120 Ohms (selectable)
• Connector 2 MB :D-sub (75/1 20 Ohms)
• 2x10/100Base-T(X) : RJ45
• Wayside 1x2 Mbit/s (option in 16x2 Mbit/s ) (75 or 120 ohms
selectable)
• In the case of Nx2 Mbit/s systems, each I/O port is independent ,therefore
the 2 Mbit/s signal can be used for different applications- such as relaying
2Mbit/s trunk line or video conferencing.

 PARALLEL ALARM INTERFACE


• Interface Relay contact (Form-C)
• Connector D-Sub (named ALM/AUX ALM)

Xi’an NEC Pasolink Introduction


IDU Interfaces (2)
 MAIN INTERFACE, ETHERNET (1 0/1
00BASE-T(X)
• Type :
• IEEE 802.3 10Base-T IEEE 802.3u/1
00Base-TX (Auto sensing or fixed)
• Port Number and Interface:
• 2 (Each port is separated ) RJ45
• Flow Control:
• 802.3x Full Duplex or Half Duplex
(Backpressure)
• Forwarding Mode: Store-and-
Forwarding
• Interface card can be used as Ethernet
Bridge compliant with IEEE 802.3
• Transmission Length: Category 5, Max
100m
• Transmission Rate:
• 2Mbps to 32 Mbps (selectable)
Depends on the system

Xi’an NEC Pasolink Introduction


E1 and LAN Bandwidth Allocation (1)

Xi’an NEC Pasolink Introduction


E1 and LAN Bandwidth Allocation (2)

Xi’an NEC Pasolink Introduction


E1 Interface

Xi’an NEC Pasolink Introduction


E1 Impedance

Xi’an NEC Pasolink Introduction


Automatic TX Power Control (1)

 The Automatic TX Power Control (ATPC) function automatically


varies the TX output power according to path conditions.
 ATPC provides the following advantages:
1. Improvement in up fading characteristics
2. Improvement in residual BER characteristic
3. Reduction of interference to intra system
4. Reduction of interference to inter system
 The ATPC Control can be used in several configuration:
ATPC-ATPC
MTPC-ATPC
ATPC-MTPC

Xi’an NEC Pasolink Introduction


Automatic TX Power Control (2)

ATPC block diagram

Xi’an NEC Pasolink Introduction


Protection switching (1)

Protection switching in Pasolink (1+1 ) system has several


switching priorities:
Priority 1: Manual switching Control
Manual switching is carried out by selecting from the front panel
OPR SEL SW [No.1–AUTO— No.2] When switched from here both
TX and RX sides switches at the same time.
Priority 2: Remote switching Control
Switching is initiated from external equipment (LCT/PNMT)
Priority 3: Automatic switching control
When the OPR SEL SW is set to Auto position, for any alarm in the
online equipment, traffic will be switched to the standby equipment
automatically. TX and RX switchover are performed independently.

Xi’an NEC Pasolink Introduction


Protection switching (2)

Xi’an NEC Pasolink Introduction


Orderwire Communication

Following Order-Wire communications are possible: Note: When the “Call”button on


Communication between Local IDU and Local ODU the IDU is pressed the buzzer
Communication between Local IDU and Remote IDU sounds on the remote IDU and
Communication between Local ODU and Remote IDU all the other IDUs connected
Communication between Local ODU and Remote ODU through back-to back
When back-to-back connection for order wire is provided, connections.
OW communication between different hops are possible.

Xi’an NEC Pasolink Introduction


OW/Rx Level Monitor ( Optional )

Xi’an NEC Pasolink Introduction


INDICATORS/SWITCHES/CONTROLS

Xi’an NEC Pasolink Introduction


Pasolink connectors for 2MB×16 system

Xi’an NEC Pasolink Introduction


IDU(1+0) CONNECTORS

Xi’an NEC Pasolink Introduction


IDU(1+1) CONNECTORS

Xi’an NEC Pasolink Introduction


ALM/AUX CONNECTORS

Xi’an NEC Pasolink Introduction


OW/DSC/ASC CONNECTORS

Xi’an NEC Pasolink Introduction


LCT--MENUS
1.Bit rate (16x2MB) INPUT LOSS AIS RCVD

TX power ctrl
1. ATPC/MTPC
2. AIS RCVD alarm/status AIS SEND OUTPUT LOSS
2. MTPC TX power WS INPUT LOSS WS AIS
3. AIS SEND alarm/status
3. ATPC TX power range RCVD WS AIS SEND
4. TX/RX frequency
4. ODU ALM mode WS OUTPUT LOSS LAN

Setting
5. TX power ctrl
5. RX threshold INTFC ALM TX CLK LOSS
6. Main channel usage 1-16 RX CLK LOSS FSYNC
00. Menu
7. BER alarm threshold ALM
99. Exit

Alarm Table
8. Frame ID 1.Thoughtput HIGH BER ALM LOW BER
9. WS channel usage ALM BER ALM

Port setting
2.Mode
Password: 10. DSC1 MOD ALM

LAN setting
3.Flow ctrl

Next Item
11. DSC2 1. Port1 setting DEM ALM
Password Change: 1. System configuration 4.Framing
12. DEM invert 2. LAN setting 2. Port2 setting OPR ALM
13. Alarm table 3. Channel usage error 3. FE link down 5.CAS TX PWR ALM RX LEV
14. Next items 00. Menu 00. Menu 6.CRC ALM APC 1 ALM
00. Menu 99. Exit 99. Exit APC2 ALM
7.Collion Report IF INPUT ALM MAINT
99. Exit
00.Menu TX SEL
1.Setting 1. MAINT
Maintenance

99.Exit RX S EL
2. FE loop back ctrl 1-16
2.Maintenance 3. NE loop back ctrl 1-16 MDP CPU ALM
(1+0) 4. BER ALM >> AIS
3.Monitoring TX power :*.** INPUT LOSS 1-16
5. CW
RX level :*.** CHANNEL USAGE ERROR 1-16
6. Power mute

IDU
4.Exit 7. ATPC manual ctrl
AIS RCVD 1-16
AIS SEND 1-16
00. Menu
OUTPUT LOSS 1-16
99. Exit
LAN INTFC ALM
Maintenance

1. to 5. same as 1+0 Manufactured date


WS INPUT LOSS
6. Power mute1 Software version
IDU

(1+1) 7. Power mute2 Bit rate WS AIS RCVD WS AIS SEND


WS OUTPUT LOSS
8. TX SW ctrl Option module
TX CLK LOSS
9. RX SW ctrl Manufactured date
RX CLK LOSS
10. ATPC manual ctrl Software version TX PWR ALM
00. & 99. same as 1+0 Bit rate FSYNC ALM RX LEV ALM
HIGH BER ALM
RF band APC 1 ALM
Monitoring

1. Monitoring voltage LOW BER ALM BER ALM


Sub band APC2 ALM
2. Monitoring voltage (con mode) MOD ALM
Start frequency IF INPUT ALM
3. Alarm/Status DEM ALM
ODU

ODU
Shift frequency MUTE
4. Inventory MDP CPU ALM
00. Menu Serial number TX FREQ CH
CH separation RX FREQ CH
99. Exit

Xi’an NEC Pasolink Introduction