Anda di halaman 1dari 16

Location

Electrical Room

System

400/230 Volts, 3

CKT.
NO.

Load Description

Mounting

Connected Load

Enclosure
Power Rating

VA

HP

Phase

Connected Load

Over Current Protection

Ampere
AN

BN

CN

AT

AF

M-1 AERATION BLOWER, AB-1

23555.2

20

34

90

100

M-2 AERATION BLOWER, AB-2

23555.2

20

34

90

100

M-3 AERATION BLOWER, AB-3

23555.2

20

34

90

100

6720.16

9.7

25

60

9.7

25

60

9.7

25

60

45

60

M-4 TRANSFER PUMP, TP-1

M-5 FEED PUMP, FP-1

6720.16

M-6 FEED PUMP, FP-2

6720.16

M-7 DECANT PUMP, DP-1

3910

17

3910

17

45

60

17

45

60

17

45

60

17

45

60

6.522

15

60

M-8 DECANT PUMP, DP-2


M-9 SLUDGE REDUCTION PUMP, SRP-1

3910

10

M-10 SLUDGE REDUCTION PUMP, SRP-2

3910

11

M-11 SLUDGE WASTING PUMP, SWP-1

3910

12

LIGHTINGS

1500
TOTAL

Calculation of IFL

111876.08

169.99 A

34

Main CB
Feeder

34

23.52 131.1

175
175

3
200

Surface
NEMA-1
Conductors

Raceway

Wires

Conduit

3-8.0 mm2 THHN + 1-5.5 mm2 THHN 20mm

PVC Schedule 40 Conduit

3-8.0 mm2 THHN + 1-5.5 mm2 THHN 20mm

PVC Schedule 40 Conduit

3-8.0 mm2 THHN + 1-5.5 mm2 THHN 20mm

PVC Schedule 40 Conduit

3-2.0 mm2 THHN + 1-2.0 mm2 THHN 15mm

PVC Schedule 40 Conduit

3-2.0 mm2 THHN + 1-2.0 mm2 THHN 15mm

PVC Schedule 40 Conduit

3-2.0 mm2 THHN + 1-2.0 mm2 THHN 15mm

PVC Schedule 40 Conduit

2-2.0 mm2 THHN + 1-5.5 mm2 THHN 15mm

PVC Schedule 40 Conduit

2-2.0 mm2 THHN + 1-5.5 mm2 THHN 15mm

PVC Schedule 40 Conduit

2-2.0 mm2 THHN + 1-5.5 mm2 THHN 15mm

PVC Schedule 40 Conduit

2-2.0 mm2 THHN + 1-5.5 mm2 THHN 15mm

PVC Schedule 40 Conduit

2-2.0 mm2 THHN + 1-5.5 mm2 THHN 15mm

PVC Schedule 40 Conduit

2-2.0 mm2 THHN + 1-2.0 mm2 THHN 15mm

PVC Schedule 40 Conduit

4-60.0 mm2 THHN + 1-14.0mm2 THHN

50mm IMC

CIRCUIT NUMBER

1
2
3
4
5
6
7
8
9
10
11
12

DESCRIPTION

M-1 AERATION BLOWER, AB-1


M-2 AERATION BLOWER, AB-2
M-3 AERATION BLOWER, AB-3
M-4 TRANSFER PUMP, TP-1
M-5 FEED PUMP, FP-1
M-6 FEED PUMP, FP-2
M-7 DECANT PUMP, DP-1
M-8 DECANT PUMP, DP-2
M-9 SLUDGE REDUCTION PUMP, SRP-1
M-10 SLUDGE REDUCTION PUMP, SRP-2
M-11 SLUDGE WASTING PUMP, SWP-1
LIGHTINGS

distance (m)

total

1.9188
2.5525
3.1604
10.0347
12.7212
14.9092
19.1944
29.821
19.2999
29.6079
22.978
61.8558
228.0538

TOTAL:
7.6317 conduits 3/4

220.4221 conduits 1/2

red

yellow
1.9188
1.9188
2.5525
2.5525
3.1604
3.1604
10.0347 10.0347
12.7212 12.7212
14.9092 14.9092
19.1944
29.821
19.2999
29.6079

red
total
#8 AWG
#10 AWG
#14 AWG

yellow
7.6317

7.6317

86.6805

86.5729

blue
white
green
1.9188
1.9188
2.5525
2.5525
3.1604
3.1604
10.0347
10.0347
12.7212
12.7212
14.9092
14.9092
19.1944 19.1944
29.821
29.821
19.2999 19.2999
29.6079 29.6079
22.978
22.978
22.978
61.8558 61.8558 61.8558

blue

white

green

7.6317
122.4989

182.757

128.5329
99.5209

10 awg GW

14 awg GW

10 awg GW

14 awg GW

Description of material
PVC Schedule 40
90 degree PVC elbow
PVC Schedule 40
90 degree PVC elbow
THHN 600V, copper wire (stranded) Red
THHN 600V, copper wire (stranded) Yellow
THHN 600V, copper wire (stranded) Blue
THHN 600V, copper wire (stranded) Green
THHN 600V, copper wire (stranded) Red
THHN 600V, copper wire (stranded) Yellow
THHN 600V, copper wire (stranded) Blue
THHN 600V, copper wire (stranded) White
THHN 600V, copper wire (stranded) Green
Circuit Breaker 90A, 3P, 480V
Circuit Breaker 25A, 3P, 480V
Circuit Breaker 45A, 1P, 240V
Circuit Breaker 15A, 1P,240V

Description of material
Intermediate Metal Conduit
90 degrees Intermediate Metal Conduit Elbow
Insulated Ground Bushing
THHN 600V, copper wire (stranded) Red
THHN 600V, copper wire (stranded) Yellow
THHN 600V, copper wire (stranded) Blue
THHN 600V, copper wire (stranded) Green
THHN 600V, copper wire (stranded) Red
THHN 600V, copper wire (stranded) Yellow
THHN 600V, copper wire (stranded) Blue
THHN 600V, copper wire (stranded) White
THHN 600V, copper wire (stranded) Green
Circuit Breaker 90A, 3P, 480V
Circuit Breaker 25A, 3P, 480V
Circuit Breaker 45A, 1P, 240V
Circuit Breaker 15A, 1P,240V

Description of material

Size
1/2"
1/2"
3/4
3/4
8 AWG
8 AWG
8 AWG
10 AWG
14 AWG
14 AWG
14 AWG
14 AWG
14 AWG
90A
25A
45A
15A

Size
1/2"
1/2"
1/2"
8 AWG
8 AWG
8 AWG
10 AWG
14 AWG
14 AWG
14 AWG
14 AWG
14 AWG
90A
25A
45A
15A

Size

12' long Aluminum Ladder Cable Tray


12" radius elbows for aluminum ladder cable tray
12" radius elbows for aluminum ladder cable tray
Drop outs for aluminum ladder cable tray
End caps for aluminum ladder cable tray
Joiners for aluminum ladder cable tray
THHN 600V, copper wire (stranded) Red
THHN 600V, copper wire (stranded) Yellow
THHN 600V, copper wire (stranded) Blue
THHN 600V, copper wire (stranded) Green
THHN 600V, copper wire (stranded) Red
THHN 600V, copper wire (stranded) Yellow
THHN 600V, copper wire (stranded) Blue
THHN 600V, copper wire (stranded) White
THHN 600V, copper wire (stranded) Green
Circuit Breaker 90A, 3P, 480V
Circuit Breaker 25A, 3P, 480V
Circuit Breaker 45A, 1P, 240V
Circuit Breaker 15A, 1P,240V

12" width
12" 90 degree flat
12" 90 degree vert.
12
12
Standard, pairs
8 AWG
8 AWG
8 AWG
10 AWG
14 AWG
14 AWG
14 AWG
14 AWG
14 AWG
90A
25A
45A
15A

Non Metallic Conduit


Man-hour/unit
3.1
0.05
3.2
0.06
9
9
9
8
6
6
6
6
6
0.5
0.5
0.2
0.2

Unit
50 ft
pc
50 ft
pc
100ft
100ft
100ft
100ft
100ft
100ft
100ft
100ft
100ft
pc
pc
pc
pc

Man-hour/unit

Metallic Conduit
Unit
Length(ft)

3.75
0.1
0.1
9
9
9
8
6
6
6
6
6
0.5
0.5
0.2
0.2

50 ft
pc
pc
100ft
100ft
100ft
100ft
100ft
100ft
100ft
100ft
100ft
pc
pc
pc
pc

Length(ft)
723.1696

Quantity (pc)

3
3
5
1

Crew
1
1
1
1
2
2
2
2
2
2
2
2
2
1
1
1
1

Quantity (pc)

Crew

26
25.0383
3
25.0384
25.0384
25.0384
421.6959
284.3848
284.0318
401.8993
599.5965
321.5121

748.208

3
3
5
1

1
1
1
2
2
2
2
2
2
2
2
2
1
1
1
1

Quantity (pc)

Crew

26
12
25.0384
25.0384
25.0384
421.6959
284.3848
284.0318
401.8993
599.5965
321.5121

Cable Tray
Man-hour/unit

Unit

Length(ft)

1
0.5
0.5
0.25
0.1
0.3
9
9
9
8
6
6
6
6
6
0.5
0.5
0.2
0.2

pc
pc
pc
pc
pc
pc
100ft
100ft
100ft
100ft
100ft
100ft
100ft
100ft
100ft
pc
pc
pc
pc

8
3
2
9
1
14
25.0384
25.0384
25.0384
421.6959
284.3848
284.0318
401.8993
599.5965
321.5121
3
3
5
1

1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
1
1
1
1

Labor Cost/hour
PHP 58.25
PHP 58.25
PHP 58.25
PHP 58.25
PHP 116.5
PHP 116.5
PHP 116.5
PHP 116.5
PHP 116.5
PHP 116.5
PHP 116.5
PHP 116.5
PHP 116.5
PHP 58.25
PHP 58.25
PHP 58.26
PHP 58.25

Labor Cost/hour
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP

58.25
58.25
58.25
116.5
116.5
116.5
116.5
116.5
116.5
116.5
116.5
116.5
58.25
58.25
58.26
58.25

Labor Cost/hour

Total hours
44.8365
1.3
1.6025
0.18
1.1267
1.1267
1.1267
16.8678
8.5315
8.5209
12.057
17.9879
9.6454
1.5
1.5
1
0.2
Total Cost

Total Labor Cost


2611.73
75.73
93.34
10.49
131.26
131.26
131.26
1965.1
993.92
992.69
1404.64
2095.59
1123.68
87.38
87.38
58.26
11.65
12005.36

Total hours

Total Labor Cost

56.1156
2.6
1.2
1.1267
1.1267
1.1267
16.8678
8.5315
8.5209
12.057
17.9879
9.6454
1.5
1.5
1
0.2
Total Cost

Total hours

page 330
page 108
page 60-63
page 385-386
page 42-44

PHP

3268.73
151.45
69.9
131.26
131.26
131.26
1965.1
993.92
992.69
1404.64
2095.59
1123.68
87.38
87.38
58.26
11.65
12704.15 PHP

Total Labor Cost

PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP
PHP

58.25
58.25
58.25
58.25
58.25
58.25
116.5
116.5
116.5
116.5
116.5
116.5
116.5
116.5
116.5
58.25
58.25
58.26
58.25

8
1.5
1
2.25
0.1
4.2
1.1267
1.1267
1.1267
16.8678
8.5315
8.5209
12.057
17.9879
9.6454
1.5
1.5
1
0.2
Total Cost

466
87.38
58.25
131.06
5.83
244.65
131.26
131.26
131.26
1965.1
993.92
992.69
1404.64
2095.59
1123.68
87.38
87.38
58.26
11.65
10207.24 PHP

breakers
wires
IMC
cable tray
PVC schedule 40

Air Terminal Rod (Traditio


Description of material
Lug with offset base for conductors
Std copper bond earth rod
Earth rod clamp
Std copper conductor coupling
Copper down conductor
Stainless steel air terminal
Plate for mast
Stainless steel mast
Steel air termination mast
Lightning counter

Size
#1/0
3/4" dia x 8' long
3/4"
3/4"
8mm diameter
30mm to 35mm
3m
2m

Early Streamer Emissio


Description of material
Lug with offset base for conductors
Std copper bond earth rod
Earth rod clamp
Std copper conductor coupling
Copper down conductor
OPR 30 stainless steel
Plate for mast
Stainless steel ESEAT mast
Lightning Counter

Size
#1/0
3/4" dia x 8' long
3/4"
3/4"
8mm diameter
30mm to 35mm
3m

Charge Dissipater
Description of material
PLP-30 Dissipater Lightning Mast
PLP--FB Fixed Base Mount
LR8-Terminal Extender
Copper down conductor
DAT-160SS Air Terminal Dissipater Stainless
GR-4 ground rods
Lightning Counter
Earth rod clamp
Lug with offset base for conductors

Size
3m
3m
8mm diameter
3/4" dia x 8' long
3/4"
#1/0

Air Terminal Rod (Traditional Lightning Rod)


Man-hour/unit
0.25
0.9
0.15
0.15
10
0.3
1.5
1
1
0.5

Unit
pc
pc
pc
pc
100ft
pc
pc
pc
pc
pc

Length(ft)

pc
pc
pc
pc
100ft
pc
pc
pc
pc

pc
pc
pc
100ft
pc
pc
pc
pc
pc

Labor Cost/hour
PHP 58.25
PHP 58.25
PHP 58.25
PHP 58.25
PHP 116.5
PHP 58.25
PHP 58.25
PHP 58.25
PHP 58.25
PHP 58.25

Quantity (pc)

Crew

Labor Cost/hour

4
6
6
2
1
1
1
1

1
1
1
1
2
1
1
1
1

PHP 58.25
PHP 58.25
PHP 58.25
PHP 58.25
PHP 116.5
PHP 58.25
PHP 58.25
PHP 58.25
PHP 58.25

Quantity (pc)

Crew

Labor Cost/hour

1
1
2

1
1
1
2
1
1
1
1
1

PHP 58.25
PHP 58.25
PHP 58.25
PHP 116.5
PHP 58.25
PHP 58.25
PHP 58.25
PHP 58.25
PHP 58.25

65.6168

Charge Dissipater Terminal Rod


Man-hour/unit
Unit
Length(ft)
1
1.25
1
10
0.3
0.9
0.5
0.15
0.25

2
2
2
2
2

Crew
1
1
1
1
2
1
1
1
1
1

114.8294

Early Streamer Emission Air Terminal Rod


Man-hour/unit
Unit
Length(ft)
0.25
0.9
0.15
0.15
10
0.3
1.5
1
0.5

Quantity (pc)
8
12
12
4

82.021
1
3
1
6
4

Total hours
2
10.8
1.8
0.6
6.5617
0.6
3
2
2
1
Total cost

Total hours
1
5.4
0.9
0.3
3.2808
0.3
1.5
1
0.5
Total cost

Total hours
1
1.25
2
4.1011
0.3
2.7
0.5
0.9
1
Total cost

Total Labor Cost


116.5
629.21
104.85
34.95
668.88
34.95
174.75
116.5
116.5
58.25
2055.34 PHP

Total Labor Cost


58.25
314.55
52.43
17.48
382.22
17.48
87.38
58.25
29.13
1017.17 PHP

Total Labor Cost


58.25
72.81
116.5
477.77
17.48
157.28
29.13
52.43
58.25
1039.9 PHP

Anda mungkin juga menyukai