Anda di halaman 1dari 14

EPON System RADIU Authorization

1. Connection Diagram
192.168.120.100

192.168.120.70

OLT

ONU

RADIUS SERVER

ONU

00:a1:02:01:a
f:c0

2. Log in EPONs command line interface

User name: admin


Password: admin;
Enable password: blank ( no
password) Enter systems sub
interface:

3. Change EPONs Radius parameters


1RADIUS authorization servers IP address, port number,KEY
Command epon(sys)# radius auth [ipaddr <ip_address>] [port
<unsigned_short>] [priority <unsigned_short>] [key <string>]

radius auth commad include 4 optional index :


ipaddr RADIUS is authorization servers IP address
port
RADIUS is the port number which the authorization server uses
priority RADIUS is the priority of the authorization server
key
: the key to communicate with Raidus
When the command didnt have any indes , it would show as follows:

Change Radius authorization server IP address to : 192.168.120.70

2RADIUS AUTH Time Interval


Commandepon(sys)# radius
interval
[<seconds>]
An optional index seconds is the radius AUTHs time interval .the budget
range is 10 to
31536000 seconds. The default budget is 60 second. User could confgure this
index according to the real fled application.
Display current Radius AUTH time interval :

Change Radius Auth time interval is 10 seconds :

4. Change ONU Authorization mode to Radius Auth.


Enter onuauth interface and display current authorization mode:

The current ONU authorization mode is noe ,meaning non


authorization. Commandepon(sysonuauth)#

type

[<blacklist | whitelist | none |


radius>]
Index :

Blacklist
2

Whitelist
None
no authorization
Radius
RADIUS Authorization
Change ONU authorization mode to Radius authorization :

5. Configure Radius authorization server index


Set up cdatas attributes :

Confgure ONU(00A10201AFC0) authorization is enabled and


confgure following confguration
CDT_ONU_LLID1_UPCIR
LLID1s uplink guaranteed bandwidth is
1024kbps CDT_ONU_LLID1_DOWNCIR LLID1s downlink guaranteed
bandwidth is 2048kbps CDT_ONU_LLID1_UPMIR
LLID1s uplink
permitted bandwidth is 1024kbps CDT_ONU_LLID1_DOWNMIR
LLID1s downlink permitted bandwidth is
1024kbps CDT_ONU_UNI1_ENABLE
Enable ONU UNIT port 1
CDT_ONU_UNI1_UPSPEED ONU UNIT port1s uplink maximum bandwidth is
512kbps
CDT_ONU_UNI1_DOWNSPEED
ONU UNIT PORT1s downlink maximum
bandwidth is
4094kbps
CDT_ONU_UNI1_VLAN
ONU Unit Port1s Vlan is 100
CDT_ONU_UNI2_VLAN
ONU Unit Port 2s Vlan is 200
CDT_ONU_UNI3_VLAN

ONU Unit Port 3s Vlan is 300

6. RADIUS Packets Exchange


RADIUS AccessRequest:

RADIUS AccessAccept:

7.

Check

information

out
via

ONUs
EMS

current

configuration

software.(No

need

configuration on EMS ,just checkout).Pls find out


the interface from the English version as follows :
ONU
LINK
Confguration:

SLA

ONU Unit Port1 s Vlan confguration:

ONU UNIT port 2s Vlan confguration:

ONU Unit port 3s vlan configuration:

ONUPON Ports Vlan configuration (PON ports Vlan confguration is made


automatically.)

ONU Unit ports speed limitation confguration

8. Radius Attribute that EPON supports


VENDOR ID18819

VENDOR NAMECDATA

ATTRIBUTES:
ID
100

NAM
E
CDT_ONU_LLID1_UPCIR

TYPE
integer

RANG
E
0~1000000 kbps

101

CDT_ONU_LLID1_DOWNCIR

integer

0~1000000 kbps

102

CDT_ONU_LLID1_UPMIR

integer

0~1000000 kbps

103

CDT_ONU_LLID1_DOWNMIR

integer

0~1000000 kbps

104

CDT_ONU_UNI1_ENABLE

integer

0:disable 1:enable

105

CDT _ONU_UNI1_UPSPEED

integer

0~100000 kbps

106

integer

0~100000 kbps

107

CDT
_ONU_UNI1_DOWNSPEED
CDT _ONU_UNI1_VLAN

integer

1~4094

108

CDT _ONU_UNI2_ENABLE

integer

0:disable 1:enable

109

CDT _ONU_UNI2_UPSPEED

integer

0~100000 kbps

110

integer

0~100000 kbps

111

CDT
_ONU_UNI2_DOWNSPEED
CDT _ONU_UNI2_VLAN

integer

1~4094

112

CDT _ONU _UNI3_ENABLE

integer

0:disable 1:enable

113

CDT _ONU _UNI3_UPSPEED

integer

0~100000 kbps

114

integer

0~100000 kbps

115

CDT _ONU
_UNI3_DOWNSPEED
CDT
_ONU _UNI3_VLAN

integer

1~4094

116

CDT _ONU _UNI4_ENABLE

integer

0:disable 1:enable

117

CDT _ONU _UNI4_UPSPEED

integer

0~100000 kbps

10

118

integer

0~100000 kbps

119

CDT _ONU
_UNI4_DOWNSPEED
CDT
_ONU _UNI4_VLAN

integer

1~4094

120

CDT _ONU _UNI5_ENABLE

integer

0:disable 1:enable

121

CDT _ONU _UNI5_UPSPEED

integer

0~100000 kbps

122

integer

0~100000 kbps

123

CDT _ONU
_UNI5_DOWNSPEED
CDT
_ONU _UNI5_VLAN

integer

1~4094

124

CDT _ONU _UNI6_ENABLE

integer

0:disable 1:enable

125

CDT _ONU _UNI6_UPSPEED

integer

0~100000 kbps

126

integer

0~100000 kbps

127

CDT _ONU
_UNI6_DOWNSPEED
CDT
_ONU _UNI6_VLAN

integer

1~4094

128

CDT _ONU _UNI7_ENABLE

integer

0:disable 1:enable

129

CDT _ONU _UNI7_UPSPEED

integer

0~100000 kbps

130

integer

0~100000 kbps

131

CDT _ONU
_UNI7_DOWNSPEED
CDT
_ONU _UNI7_VLAN

integer

1~4094

132

CDT _ONU _UNI8_ENABLE

integer

0:disable 1:enable

133

CDT _ONU _UNI8_UPSPEED

integer

0~100000 kbps

134

CDT _ONU
_UNI8_DOWNSPEED
CDT
_ONU _UNI8_VLAN

integer

0~100000 kbps

integer

1~4094

135

11

Anda mungkin juga menyukai