Anda di halaman 1dari 12

PROJECT

DATA SHEET FOR CORROSION INHIBITOR INJECTION ACCESS FITTING


MANUFACTURER:

SERVICE: PRODUCED WATER

1
2

SIZE: REFER BELOW

TAG NO.

3 DESCRIPTION

SPECIFICATION REQUIREMENT

4 GENERAL DATA
5 ACCESS FITTING TYPE

RETRACTABLE TYPE

6 ASME CLASS / RATING

150#

7 INLET NOZZLE SIZE & CONFIGURATION

1", FLANGED (RF), SMOOTH FINISH (125-250 in)

8 HEADER CONNECTION SIZE & CONFIGURATION

2", FLAREWELD, 6000#

9 PIPING CLASS

A1E

10 CORROSION ALLOWANCE

3 MM

11 BODY TYPE

TEE TYPE WITH SOLID PLUG ASSEMBLY AND HEAVY CS

12

PROTECTIVE COVER

13 INJECTION TUBE

ATOMIZING INJECTION QUILL TYPE

14 INSTALLATION / MOUNTING

AT 12 O CLOCK POSITION ON HEADER ABOVE GROUND

As in MTO

19 BODY / FLANGE

A105

20 INTERNALS / SOLID PLUG

SS316

21 PROTECTIVE COVER

A105

22 INJECTION TUBE / QUILL

SS316

23 PRIMARY PACKING AND BACK UP RING

PTFE

24 O-RING

VITON (ANTI EXPLOSIVE DECOMPRESSION TYPE)

25 PIPE PLUG

SS316

28 DESIGN CODE

PRESSURE RETAINING PARTS AS PER ASME B31.3

29 FACE TO FACE DIMENSIONS

AS PER MANUFACTURER'S STANDARD

15
16 HEADER PIPE DETAILS
17
18 MATERIALS

26
27 CODES AND STANDARDS / TESTING / CERTIFICATION

30 FLANGE END DIMENSIONS

AS PER ASME B16.5

31 HYDRO STATIC TEST

1.5 TIMES OF DESIGN PRESSURE (MINIMUM)

32 NDT. (MPI / DP / RADIOGRAPHY / UT ETC.)

AS PER ASME B 31.3

33 MATERIAL CERTIFICATION

EN 10204 TYPE 3.1

34 PAINTING

AS PER MANUFACTURER'S STANDARD

MSS SP 25

35
36 MARKING
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52

VENDOR'S CO

53
54
55
56
57
58
59
60
61
62
63
64

OSION INHIBITOR INJECTION ACCESS FITTING


REFER BELOW

VENDOR'S CONFIRMATION

PROJECT

DATA SHEET FOR CORROSION COUPON ACCESS FITTING


MANUFACTURER:

SERVICE: PRODUCED WATER

1
2

SIZE:

2"

TAG NO.

3 DESCRIPTION

SPECIFICATION REQUIREMENT

4 GENERAL DATA
5 ACCESS FITTING TYPE

RETRACTABLE, INTRUSIVE, MULTI STRIP TYPE

6 ASME CLASS / RATING

150#

7 END CONFIGURATION

FLAREWELD, 6000#

8 PIPING CLASS

A1E

9 CORROSION ALLOWANCE

3 MM

NON-TEE TYPE WITH SOLID PLUG ASSEMBLY AND HEAVY CS

10 BODY TYPE
11
12 STRIP HOLDER

PROTECTIVE COVER
:

13

SUITABLE FOR HOLDING THREE STRIPS FOR TOL, MOL


& BOL MONITORING

AT 12 O CLOCK POSITION ON HEADER ABOVE GROUND

As per MTO

21 BODY

A105

22 INTERNALS

SS316

23 PROTECTIVE COVER

A105

24 STRIP / COUPON

SAME AS HEADER PIPE MATERIAL OR EQUIVALENT

25 STRIP HOLDER

SS 316

26 PRIMARY PACKING

PTFE

27 O-RING

VITON (ANTI EXPLOSIVE DECOMPRESSION TYPE)

28 PIPE PLUG

SS316

31 DESIGN CODE

PRESSURE RETAINING PARTS AS PER ASME B31.3

32 FACE TO FACE DIMENSIONS

AS PER MANUFACTURER'S STANDARD

33 HYDRO STATIC TEST

1.5 TIMES OF DESIGN PRESSURE (MINIMUM)

34 NDT. (MPI / DP / RADIOGRAPHY / UT ETC.)

AS PER ASME B 31.3

35 MATERIAL CERTIFICATION

EN 10204 TYPE 3.1

36 PAINTING

AS PER MANUFACTURER'S STANDARD

MSS SP 25

14 INSTALLATION / MOUNTING
15
16 HEADER PIPE DETAILS
17
18
19
20 MATERIALS

29
30 CODES AND STANDARDS / TESTING / CERTIFICATION

37
38 MARKING
39
40
41
42
43
44
45
46
47
48
49
50
51
52

VENDOR

53
54
55
56
57
58
59
60
61
62
63

VENDOR'S CONFIRMATION

Internal Ctrl. No.: 401910-G


EPC CONTRACTOR

PROJECT

AHDEB OILFIELD SURFACE FACILITIES


DEVELOPMENT PROJECT

AREA
DOCUMENT

GENERAL

PROJECT NO.
DOCUMENT NO.

401910
AHD-GEN-L-DS-00010

PAGE NO.

23

DATA SHEET FOR CORROSION COUPON ACCESS FITTING

MANUFACTURER:

SERVICE:

OF

23

REV.: 1

SIZE:

1
2
3 NOTES:
4

The corrosion coupon access fitting shall be suitable for inserting or retrieving the coupons while the line is in operation.
The corrosion coupon shall allow safe operation and be of a compact design requiring minimum clearances.

5
6
7

Vendor shall consider the corrosion allowance (as indicated) in its calculation as a minimum.

Vendor shall submit the catalogues and its relevant calculations as part of its offer.

TOL, MOL & BOL Monitoring stands for Top of Line, Middle of Line & Bottom of Line Monitoring.

The Corrosion Inhibitor Injection Access Fitting shall be suitable for inserting or retrieving the injection quill while the line is in Operation.

8
9
10
11
12
13

The injection quill shall allow safe operation and be of a compact design requiring minimum clearances.

14
15
16

Only Corrosion Inhibitor Injection Access Fitting with single forged or welded tees are acceptable. Threaded tee fittings are not accepted.

Vendor to quote for the retrieving tool aswell.

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51

52
53
54
55
56
57
58
59
60
61
62
63

Internal Ctrl. No.: 401910-GEN-EP17-010


CLIENT

401910
AHD-GEN-L-DS-00010
23
REV.: 1

able for inserting or retrieving the injection quill while the line is in Operation.

orged or welded tees are acceptable. Threaded tee fittings are not accepted.

QTY: