INDEX*
COMPATIBILITIES
All registered product names referenced herein are trademarks of their respective companies.
Trademark belongs to a third party and is no way associated to Implant Protesis Dental 2004 SL (IPD).
KLOCKNER - ESSENTIAL
10
12
*Implant Protesis Dental 2004 SL (IPD) provides prosthetic solutions which have compatible connection with different implant systems.
The components IPD manufactures and markets are fully functional on those systems.
COMPATIBILITY
All registered product names referenced herein are trademarks of their respective companies.
Trademark belongs to a third party and is no way associated to Implant Protesis Dental 2004 SL (IPD).
INTERFACE
ENGAGING
IPD/JA-IN-00 [ 3.3 ]
NON-ENGAGING
IPD/JA-IN-01 [ 3.3 ]
ANALOG
REFERENCE:
IPD/JA-AN-00 [ 3.3 ]
IPD/JA-AR-00 [ 3.8 ]
IPD/JA-AW-00 [ 4.3 ]
SCREW
COMPATIBILITY
KLOCKNER- ESSENTIAL
All registered product names referenced herein are trademarks of their respective companies.
Trademark belongs to a third party and is no way associated to Implant Protesis Dental 2004 SL (IPD).
INTERFACE
[implant level]
ENGAGING
REFERENCE:
IPD/CB-IR-00 [ 4.5 ]
IPD/CB-IW-00 [ 6.0 ]
NON-ENGAGING
REFERENCE:
IPD/CB-IR-01 [ 4.5 ]
IPD/CB-IW-01 [ 6.0 ]
ANALOG
REFERENCE:
SCREW
IPD/CB-AR-00 [ 4.5 ]
IPD/CB-AW-00 [ 6.0 ]
[implant level]
REFERENCE: IPD/CB-TR-00
[ 4.5 / 6.0 ]
COMPATIBILITY
All registered product names referenced herein are trademarks of their respective companies.
Trademark belongs to a third party and is no way associated to Implant Protesis Dental 2004 SL (IPD).
INTERFACE
ENGAGING
IPD/IB-IR-00
REFERENCE: IPD/IB-IR-02
NON-ENGAGING
IPD/IB-IR-01
REFERENCE: IPD/IB-IR-03
ANALOG
REFERENCE: IPD/IB-AR-00
SCREW
REFERENCE: IPD/IB-TR-00
Balance base narrow
REFERENCE: IPD/IB-TR-01
Compatible with non-engaging Interfaces and
CAD/CAM structures
COMPATIBILITY
All registered product names referenced herein are trademarks of their respective companies.
Trademark belongs to a third party and is no way associated to Implant Protesis Dental 2004 SL (IPD).
CASTABLE ABUTMENT
ENGAGING
IPD/LB-HN-00 [ 3.5 ]
IPD/LB-HW-00 [ 5.7 ]
NON-ENGAGING
REFERENCE:
IPD/LB-RN-00 [ 3.5 ]
IPD/LB-RR-00 [ 4.5 ]
IPD/LB-RW-00 [ 5.7 ]
NON-ENGAGING
IPD/LB-BN-01 [ 3.5 ]
COMPATIBILITY
All registered product names referenced herein are trademarks of their respective companies.
Trademark belongs to a third party and is no way associated to Implant Protesis Dental 2004 SL (IPD).
INTERFACE
ENGAGING
REFERENCE:
IPD/LB-IN-00 [ 3.5 ]
IPD/LB-IR-00 [ 4.5 ]
NON-ENGAGING
IPD/LB-IN-01 [ 3.5 ]
ANALOG
REFERENCE:
IPD/LB-AN-00 [ 3.5 ]
IPD/LB-AR-00 [ 4.5 ]
IPD/LB-AW-00 [ 5.7 ]
SCREW
REFERENCE
HEIGHT (mm)
IPD/AA-LR-01
IPD/AA-LR-03
COMPATIBILITY
PLATFORM
4.1
IPD/AC-LR-01
IPD/AC-LR-03
IPD/AC-LR-05
IPD/AD-LR-01
IPD/AD-LR-03
IPD/AD-LR-05
IPD/BB-LR-01
IPD/BB-LR-03
IPD/BB-LR-05
IPD/DA-LR-01
IPD/DA-LR-03
IPD/DB-LR-01
IPD/DB-LR-03
IPD/DB-LR-05
IPD/EA-LR-01
IPD/EA-LR-03
IPD/EA-LR-05
IPD/EA-LW-01
IPD/EA-LW-03
IPD/EA-LW-05
IPD/FA-LN-01
IPD/FA-LN-03
IPD/FA-LN-05
Phibo TSH
4.3
4.3
4.3
Biomet 3i Certain
4.1
4.8
4.1
Astra OsseospeedTM Tx
3.5 / 4.0
Astra OsseospeedTM Tx
4.5 / 5.0
3.5
3.7
ACCESSORIES
IPD/PS-AR-00
PSD analog
IPD/KA-CL-00
IPD/KA-CL-01
IPD/KA-CL-02
10
L1
L2
REFERENCE
IPD-AATN50
IPD-AATR50
IPD-AATR52
COMPATIBILITY
PLATFORM*
3.3
3.5
4.1
SEAT
LENGTH*
L1=head / L2=body
METRIC
140
2.01 / 4.79
M1.6
75
1.75 / 5.45
M2
180
1.4 / 4.4
M2
IPD-AATW50
5.1
140
1.61 / 4.8
M2.5
IPD-ABTR50
Multiunit
4.8
180
1.5 / 2.1
M1.4
IPD-ACTN50
3.5
180
1.4 / 6.1
M1.8
4.3 / 5.0
Astra OsseospeedTM Tx
4.5 / 5.0
180
1.4 / 7.4
M2
4.3
180
1.4 / 4.4
M2
180
1.5 / 6.5
M1.6
4.3
90
1.5 / 3.0
M1.8
IPD-ACTR50
IPD-ADTR50
IPD-BBTR51
Biomet 3i Certain
IPD-CATR50
Klockner SK2
IPD-DATR50
4.8 / 6.0
90
1.65 / 3.32
M2
IPD-DATR51
4.8 / 6.0
30
2.52 / 3.58
M2
IPD-DBTR50
3.3 / 4.1
30
2.25 / 5.55
M1.6
IPD-EATR50
Astra OsseospeedTM Tx
3.5 / 4.0
180
1.5 / 6.3
M1.6
IPD-EATR51
Astra Uni 20 / 45
All
180
1.5 / 2.9
M1.4
IPD-FATR50
140
1.62 / 5.48
M1.8
IPD-GATN50
3.5
180
1.5 / 3.6
M2
IPD-GBTR50
4.1
180
1.5 / 5.0
M1.8
IPD-HATN50
3.5
140
1.59 / 4.01
M1.8
IPD-HATR50
4.2 / 5.1
120
1.72 / 4.28
M2
IPD-LBTR50
BioHorizons Internal
90
1.78 / 4.92
M1.8
IPD-MBTN50
3.3 / 3.8
120
1.67 / 5.33
M1.8
IPD-MBTR50
4.25 / 5.0
120
1.65 / 5.25
M2
*Units: mm
HEAD
2.3mm for all [Except: IPD/AA-TW-50, 2.8mm]
DIAMETER
11
12
WORK SEQUENCES
The permanent screwdriver is inserted
through the Hollow Screw so that the
permanent screw can be easily tightened
or loosened.
The crown is fixed mechanically to the
Interface by means of a Hollow Screw. No
glue or bonding material is needed during
the working process or try-in.
ADVANTAGES
CAD/CAM: The scanning process in the lab and the components
handling are simplified. Libraries available for: Exocad, Dentalwings,
3Shape, EGS, Delcam and Imetrics.
Uncemented temporary fixation: No cement used in any of the stages of
the prosthesis manufacturing and adjusting: Metal try- in, Bisque try-in
and occlusion test.
Oxidation free: As the interface does not require to be heated in the
furnace in order to remove temporary cement, there is no oxidation on its
surface. It maintains dimensional integrity and surface color, resulting in a
superior appearance and a precise adjustment with the implant.
Less time and cost: Labor time and cost reduction.
Security fixation system: The Hollow screw is made of Grade 5 titanium
and consequently it can be used as a permanent security fixation system
while keeping the trans-occlusal channel free of the excess of bonding
material. In no case, however, it is meant to replace the permanent
cementation.
Gingiva heights available: Gives solutions for almost all clinical cases and
allows to keep the cement away from the tissues.
Without sandblasting: The parallel and engraved walls of the
supraconnection give an extra retention for the cement, being possible to
avoid the sandblasting.
TiN coated: The gold like color TiN coating offers a warmer and more
natural color to the restoration, avoiding the shadows in the crown.
Higher ceramic thickness: The parallel walls allow higher thickness of
ceramics, reducing shadows even in compromised restorations.
Standardized supraconnection: The standardized supraconnection reduces
the stock of components required, as a result IPD Interface system is the
most cost-effective interface system on the market.
13
HEADQUARTERS
Cam del Mig, 71
08302 Matar (Barcelona - Spain)
Phone (+34) 93 193 10 67
Fax (+34) 93 757 18 44
export@ipd2004.com
www.ipd2004.com