Anda di halaman 1dari 44

Installation Guide

inBIO-Series
Access Control Panels
&

ZKAccess 5.2 software


ZKAccess.com

AUX 1

AUX 2 AUX 3

AUX4

EXT

STATE

BUTTON 1

READER 1

BUTTON 2

EXT
RS485

READER 2

BUTTON 3

PC
RS485

READER 3

BUTTON 4

CARD

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

GRD

ACT

RUN

485+

PWR

485-

GND

+12V

GND

IN

GND

IN

GND

IN

GND

IN

Whats in the Box

READER 4

RUN

POWER

Best Security Solution for the World

A d v a nced A c c es s Con tr ol

2 Screws & Anchors

2 Screwdriver

4 Diode

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

GND

+12V

V-

V+

LOCK POWER
NC

COM

NO

GND

SEN

LOCK4
NC

COM

NO

GND

SEN

LOCK3
NC

COM

NO

GND

SEN

LOCK2
NC

COM

NO

GND

LOCK1
SEN

NC

COM

NO

NC

COM

AUXOUT3 AUXOUT4
NO

NC

COM

AUXOUT2
NO

NC

COM

NO

AUXOUT1
SGND

PC
485-

SWITCH
485+

LAN

CONTENT
Whats in the Box........................................................................2
Optional accessories. . ..............................................................4
Safety Precautions.....................................................................5
Product PIN Diagram. . .............................................................6
LED Indicators...............................................................................7
Product Dimension.. .................................................................8
Installation of Panel & Cabinet. . ........................................9
Wiring Legend. . ......................................................................... 10
Power Wiring Diagram . . ..................................................... 11
FR1200 Connection. . ............................................................. 12
DIP Switch Setting for FR1200 Device ID. . ............. 13
Wiegand Connection.. ......................................................... 14
REX Connections..................................................................... 15
Lock Connection..................................................................... 16
Normally Open Lock Powered From Lock Terminal.......... 16
Normally Closed Lock Powered From Lock Terminal. . ...... 16
Switching Wet Contact to Dry Contact.. ............................... 17
Connecting a lock with external power supply................. 18

ZKAccess 5.2
software
Installation and Setup
starts at page 30

Aux. I/O connection.............................................................. 19


Aux. Input Connection.. ............................................................. 19
Aux. Output Connection. . ......................................................... 19

Ethernet Connection .......................................................... 20


LAN Connection.......................................................................... 20
Direct connection....................................................................... 20

RS485 Connection ................................................................ 21


Restore factory setting............................................................... 22

DIP Switch Setting.................................................................. 23


RS485 Address.............................................................................. 23
Terminal Resistance.................................................................... 23

Typical Installation.................................................................. 24
Troubleshooting...................................................................... 25
PC 485 Setting Table............................................................. 26
Electrical Specifications ..................................................... 28
Specifications ............................................................................ 29

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

Optional accessories

Wiegand Card Reader

Prox Card

RS485 Convertor

K1-1 Exit Button

ZK4500 Enrollment reader

CR10E Card Enroller

FR1200 FP & Prox Reader

inBIO Cabinet

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

Safety Precautions
The following precautions are to keep users safe and prevent any damage.
Please read carefully before installation
Do not install the device in a place subject to direct sun
light, humidity, dust or soot
Do not place a magnet near the product. Magnetic objects
such as magnet, CRT, TV, monitor or speaker may damage
the device.
Do not place the device next to heating equipment
Be careful not to let liquid like water, drinks or chemicals
leak inside the device.
Do not let children touch the device without supervision
Do not drop or damage the device
Do not disassemble, repair or alter the device.
Do not use the device for any other purpose than specified.
Clean the device often to remove dust on it. In cleaning, do
not splash water on the device but wipe it out with smooth
cloth or towel.
Contact your supplier in case of a problem.

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

Figure 1

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
GND

+12V

LOCK4

V-

BUTTON 4

V+

NC

COM

LOCK3

NO

CARD

GND

READER 3

SEN

NC

COM

NO

LOCK2

GND

BUTTON 3

Lock Power
inBIO Power

4 Lock & Door Sensor


SEN

NC

PC
RS485

COM

READER 2

NO

LOCK1

GND

SEN

NC

BUTTON 2

COM

NO

AUXOUT3 AUXOUT4

GND

EXT
RS485

SEN

READER 1

NC

COM

NO

BUTTON 1

NC

COM

AUXOUT2

NO

NC

COM

AUXOUT1

4 Aux Output

STATE

NO

NC

EXT

COM

PC

NO

SWITCH
SGND

AUX4

485-

AUX 2 AUX 3

RS485 Communication
485+

LAN

DIP Switches

AUX 1

ACT LED

Ethernet Port

LINK LED

SD Card Slot

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

GRD

ACT

RUN

PWR

485+

485-

GND

+12V

GND

IN

GND

IN

GND

IN

GND

IN

#4 Door Card Reader

#4 Door Exit Button

#3 Door Card Reader

#3 Door Exit Button

#2 Door Card Reader

#2 Door Exit Button

#1 Door Exit Button

#1 Door Card Reader

State Indictor

FR1200
Fingerprint Reader

4 Aux Inputs

Product PIN Diagram

READER 4

RUN
POWER

Best Security Solution for the World

A d v a nced A c c es s Con tr ol

LOCK POWER

LED Indicators
LINK Solid Green LED indicates TCP/IP

is normal
1 2 3 4 5 6communication
78

+12V

BUTTON 2

READER 2

POWER

READER 4

GND

GLED

BEEP

GND

GND

GLED

+12V

WD0

WD1

IN

WD0

WD1

+12V

+12V

GND

WD0

GLED

BEEP

GND

+12V

GND

WD0

GLED

WD1

WD1

IN

GND

+12V

COM

GND

SEN

COM

GND

SEN

COM

V-

V+

NC

GND

LOCK POWER
+12V

COM

GND

LOCK4
SEN

COM

NO

NC

NO

NC

LOCK3
SEN

+12V
COM

LOCK2

V-

V+

NC

NO

NC

NO

Flashing (RUN) Green LED indicates


that panel is in normal working state.
NC

COM
BEEP
NC
GLED

+12V
SEN
IN
GND
GND
NO

WD1
NO
WD0
COM
GND
NC

BUTTON 4

Flashing (POWER) Red LED indicates


the panel is powered on.

Figure 7

GND

+12V

V-

V+

NC

COM

NO

Figure 8

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
GND

+12V

V-

V+

NC

COM

NO

GND

SEN

LOCK4
NC

COM

NO

GND

SEN

RUN

Flashing (CARD) Yellow LED indicates


that
the card is read by the panel.
POWER

POWER
A d v aLOCK
nced
A c c es s Con tr ol

LOCK3
NC

GND

CARD

LOCK2
COM

SEN

NC

COM

NO

GND

SEN

NC

POWER
A d v aLOCK3
nced ALOCK4
c c esLOCK
s Con
tr ol

COM

NO

GND

READER 3

RUN

PC
RS485

GND

COM
BEEP
NC
GLED

BUTTON 3

CARD

LOCK2

GND
NO

NC
IN

GND
NO
+12V
COM

COM
WD1
NC
WD0

SGND
BEEP
NO
GLED

485GND

485+
IN

+12V

PC
AUXOUT2 AUXOUT3 AUXOUT4
LOCK1
A
d vAUXOUT1
a nced
A c c es s Con tr
ol

POWER
A d v aLOCK3
nced ALOCK4
c c esLOCK
s Con
tr ol

GND

POWER

Figure 6

NO

SEN

NC

COM

LOCK2

READER 4

RUN

CARD

NO

LOCK1

GND
NC
+12V
SEN

WD1
NO
WD0
COM

COM
BEEP
NC
GLED

GND
NO

BUTTON 4

in progress

GND

Figure 5

AUXOUT3 AUXOUT4

NC
IN

+12V
COM

GND
NO

READER 3

PC RS485 (TX/RX) Flashing Yellow


&
Green
LED indicates
communication
is
CARD
RUN
POWER

WD1
SEN
WD0
GND
GND
NO

BUTTON 3

BEEP

IN

BUTTON 3

PC
RS485

AUXOUT2

485+
IN
485GND
SGND
BEEP
NO
GLED
COM
WD1
NC
WD0

+12V

AUXOUT1

READER 4

EXT RS485 (TX/RX) Flashing Yellow


READER 3
BUTTON 4
READER 4
&
Green
LED indicates
communication
is
CARD
RUN
POWER
in progress

READER 2

READER 4

EXT
RS485

PC

BUTTON 4

A d v a nced A c c es s Con tr ol
GND

WD0

WD1

GLED

BEEP

GND

IN

BUTTON 4

GND

+12V

GND

WD0

GLED

BUTTON 2

GND

READER 3

READER 3

2 3 4 5 6 7 8

PC
RS485

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

BUTTON 3

BEEP

BUTTON 3

Figure 4

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

BEEP

GND

IN

+12V

READER 1

READER 2

O
N 1

EXT
RS485

Flashing (ACT )Yellow LED indicates

1 2 3 4 5 data
6 7 communication
8
is in progress

BUTTON 2

GND

WD0

WD1

GLED

BEEP

GND

IN

ACT

RUN

PWR

485+

GRD

BUTTON 1

2 3 4 5 6 7 8

WD1

READER 1

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

GRD

BUTTON 1

STATE

NO

GND

EXT

GND

ACT

RUN

PWR

485+

STATE

Figure 3
485-

GND

EXT

GND

O
N 1

Figure 2
485-

GND

Product Dimension

Best Security Solution for the World

EXT
RS485

Best Security Solution for the World

PC
RS485

EXT
RS485

EXT
RS485

RUN

RUN

POWER

POWER

A d v a nced A c c es s Con tr ol

CARD

CARD

RUN

POWER

A d v a nced A c c es s Con tr ol

PC
RS485

CARD

A d v a nced A c c es s Con tr ol

PC
RS485

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

8.89in
(226mm)
Best Security Solution for the World

Figure 10

3.56in
(90.5mm)

15.7in (400mm)

1.42in (36mm)
4.17in (106mm)
4.17in (106mm)
4.17in (106mm)

7.125in
(181mm)

inBIO-460
inBIO-260
inBIO-160

Figure 9

inBIO- Metal Cabinet

13in
(330mm)

Installation of Panel & Cabinet


Cable Conduit
(Punch Hole for cables)

AUX 1

BUTTON 1

READER 1

BUTTON 2

EXT
RS485

READER 2

BUTTON 3

PC
RS485

READER 3

BUTTON 4

CARD

inBIO Panel

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

485+

GND

IN

+12V

GND

485-

STATE

GRD

GND

EXT

ACT

IN

AUX4

RUN

GND

IN

GND

AUX 2 AUX 3

PWR

IN

GND

IN

Temper Switch
READER 4

RUN

POWER

Best Security Solution for the World

A d v a nced A c c es s Con tr ol

--

Heat Dissipation Grill

GND

+12V

V-

V+

LOCK POWER
NC

COM

NO

GND

SEN

LOCK4
NC

COM

NO

GND

SEN

LOCK3
NC

COM

NO

GND

SEN

LOCK2
NC

COM

NO

GND

LOCK1
SEN

NC

COM

NO

NC

COM

AUXOUT3 AUXOUT4
NO

NC

COM

AUXOUT2
NO

NC

COM

NO

AUXOUT1
SGND

PC
485-

SWITCH
485+

LAN

Power Supply
Backup Battery

Figure 11

Step 1

Pass the cable through holes

State Indicators

Step 2

Mount the Metal Cabinet

Mounting Holes

Step 3

Insert the inBIO Panel as it shown

Inserting Panel to Rail

2
Mounting Rail
Figure 12

We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be
found, then use the supplied drywall plastic mollies (anchors).
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

Figure 13

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
GND

+12V

V-

LOCK4

V+

NC

BUTTON 4

12V DC Power

12V DC Power Supply

COM

LOCK3

NO

CARD

GND

READER 3

SEN

NC

COM

LOCK2

NO

BUTTON 3

GND

SEN

NC

PC
RS485

COM

READER 2

NO

LOCK1

GND

SEN

NC

COM

BUTTON 2

Normally Close Lock

Normally Open Lock

AUXOUT3 AUXOUT4

NO

GND

EXT
RS485

SEN

READER 1

NC

COM

NO

NC

BUTTON 1

COM

AUXOUT2

NO

NC

AUXOUT1

COM

STATE

NO

NC

COM

PC

NO

SGND

SWITCH
485-

EXT

ALARM

485

LAN
AUX4

Floodlight

RS

AUX 2 AUX 3

485 Convertor

485+

AUX 1
+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

GRD

ACT

RUN

PWR

485+

485-

GND

+12V

GND

IN

GND

IN

GND

O TEST WE
HT

PUS

IN

GND

IN
LY
EK

PUS

LY
EK

EXIT

No Touch

O TEST WE
HT

Ethernet Cable

PUSH

FIRE
ALARM

Card Reader

Exit Button

Card Reader

Exit Button

IR Sensor

Detector

10

Wiring Legend

READER 4

RUN
POWER

Best Security Solution for the World

A d v a nced A c c es s Con tr ol

LOCK POWER

A d v a nced A c c es s Con tr ol

UTTON 3

READER 3

BUTTON 4

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

Power Wiring Diagram

GND

IN

11

READER 4

+12V

CARD

GND

+12V

V+

NC

COM

GND

V-

V+

+12V

LOCK POWER
NC

COM

NO

GND

NC

SEN

LOCK4

COM

NO

GND

NC

SEN

LOCK3

COM

GND

SEN

NC

COM

NO

LOCK2

V-

WD0

WD1

GLED

BEEP

GND

GND

NO

POWER

A d v a nced A c c es s Con tr ol

LOCK1

LOCK POWER

READER 4

RUN

SEN

NC

LOCK4

BUTTON 4

GND

READER 3

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

BUTTON 3

CARD

GND

COM

NO

NC

COM

AUXOUT3 AUXOUT4

IN

+12V

GND

WD0

WD1

GLED

BEEP

READER 2

PC
RS485

NO

NC

AUXOUT2
COM

NC

NO

COM

AUXOUT1
SGND

485+

PC
485-

SWITCH

LAN

NO

NO

Best Security Solution for the World

GND

BUTTON 2

NO

READER 1

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

BUTTON 1

EXT
RS485

SEN

STATE

NC

EXT

COM

IN

IN

AUX4

IN

GRD

ACT

RUN

PWR

485+

485-

GND

+12V

GND

GND

GND

AUX 2 AUX 3

GND

SEN

IN

IN

LOCK3

AUX 1

NC

COM

NO

OCK2

GND

Without Backup Battery

RUN

POWER

24V AC

AC
N

BT+ BT-

A d v a nced A c c esGround
s Con tr ol

Switching Power Supply

Figure 14

With Backup Battery


GND

+12V

V-

V+

READER 4

RUN

LOCK POWER
NC

+12V

GND

WD0

WD1

GLED

BEEP

GND

BUTTON 4

CARD

COM

READER 3

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

BUTTON 3

PC
RS485

NO

READER 2

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

BUTTON 2

EXT
RS485

GND

READER 1

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

BUTTON 1

SEN

STATE

GRD

ACT

RUN

PWR

EXT

NC

485+

485-

GND

+12V

GND

AUX4

LOCK4

COM

AUX 2 AUX 3

IN

GND

IN

GND

NO

AUX 1

IN

GND

IN

POWER

Best Security Solution for the World

A d v a nced A c c es s Con tr ol

GND

+12V

V-

V+

LOCK POWER
NC

COM

NO

GND

SEN

LOCK4
NC

COM

NO

GND

SEN

LOCK3
NC

COM

NO

GND

SEN

LOCK2
NC

COM

NO

GND

LOCK1
SEN

NC

COM

NO

NC

COM

AUXOUT3 AUXOUT4
NO

NC

COM

AUXOUT2
NO

NC

COM

AUXOUT1
NO

PC
SGND

SWITCH

485-

LAN

485+

GND

SEN

LOCK3
NC

COM

K2

--

24V AC

AC
N

BT+ BT-

Ground

Switching Power Supply

Figure 15
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

12

FR1200 Connection

AUX 1
AUX 2 AUX 3

IN

AUX4

Best Security Solution for the World

ETHERNET

IN

IN

GND

GND
IN
GND

GND
+12V

IN

AUX4

IN

GND

GND

EXT

AUX 2 AUX 3

SWITCH

AUX 1

Best Security Solution for the World

LAN

IN

IN

EXT

GND
485485+

PC

485-

485485+

GND
+12V

485+

GND

GND

SGND

NC

NO
COM

READER 2

NC

COM
NC

+12V
GND

READER 4

V-

LOCK POWER

V+

IN
GND

GLED
WD1
GND

IN
GND

GLED
WD1
WD0
GND

IN
GND
BEEP

RUN
ACT
GRD

WD0

+12V
RUN

NO

LOCK4

GND

BUTTON 4

SEN

GND

BUTTON 1

COM

WD0

BEEP
READER 3

NO

LOCK3

GND

BUTTON 3

SEN

IN
GND

GLED

BEEP

WD1
WD0
GND
+12V

GLED

POWER

A d v a nced A c c es s Con tr ol

NC

CARD

COM

WD1

+12V

LOCK2

EXT
RS485

SEN
NO

GND

BEEP

NC

GND

BUTTON 2

COM

PWR

IN

+12V

LOCK1

NO

GRD

GLED

SEN
GND

ACT

BEEP

PC
RS485

NC

RUN

STATE

NC

READER 1

COM

AUXOUT3 AUXOUT4

NO

PWR

BUTTON 1

NC

EXT
RS485

COM

AUXOUT2

NO

STATE

COM

AUXOUT1

NO

READER 1

WD1
WD0
GND
+12V

BUTTON 2

PC
RS485

IN
GND
BEEP

2 FR1200

READER 2

1 FR1200

GLED
WD1

12V DC

12V DC

WD0

GND
3 FR1200

8 FR1200

+12V
BUTTON 3

CARD

GND

inBIO panels can not supply power to


more than 2 FR1200 readers.
BEEP
Addidional FR1200 will require external power supplies.
READER 3

A d v a nced A c

Figure 16IN

GLED
WD1
WD0
GND

RUN

BUTTON

+12V
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION
GUIDE
IN

13

DIP Switch Setting for FR1200 Device ID


1 2 3 4 5 6

RS485 Terminal Resistance

ON

8
4
2
1

DIP Switch
Figure 17

Address

Switch Settings

Address

ON

1 2 3 4 5 6
ON

ON

1 2 3 4 5 6
ON

1 2 3 4 5 6
ON

1 2 3 4 5 6
ON

1 2 3 4 5 6

Switch Settings
ON

1 2 3 4 5 6
ON

1 2 3 4 5 6

1 2 3 4 5 6

3. If FR1200 is powered from inBIO-

Important Notes

1. There are six DIP switches on the

back of FR1200, Switches 1-4 is for


RS485 address, switch 5 is reserved,
switch 6 is for reducing noise on long
RS485 cable.

2. Set the odd number for IN reader,

and the even number for OUT reader


(for eg. For two readers for one doorthe RS485 address 1 is for IN reader,
RS485 address 2 is for OUT reader)

Panel, the length of wire should be


less than 100 meters or 330 ft.

4. The External RS485 interface can

supply maximum 500mA current,


The FR1200s startup current is
240mA. So inBIO-Panel only can only
power two FR1200s.

5. If the cable length is more than

200 meters or 600 ft , the number 6


switch should be ON as below

ON

ON

Distance: More than 200 meters


1 2 3 4 5 6

1 2 3 4 5 6

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

14

Wiegand Connection
DC+(6-14V)
GND
Wiegand D0
Wiegand D1
Green LED
Beeper

AUX 2 AUX 3

AUX4

EXT

STATE

BUTTON 2

READER 2

BUTTON 4

+12V

GND

WD0

WD1

GLED

BEEP

READER 2

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

READER 3

EXT
RS485

READER 4

PC
RS485

EXT
RS485

PC
RS485

CARD

RUN

POWER

Best Security Solution for the World

A d v a nced A c c es s Con tr ol

GND

+12V

V-

V+

NC

LOCK POWER

COM

NO

GND

SEN

LOCK4
NC

COM

NO

GND

SEN

LOCK3
NC

COM

NO

GND

SEN

LOCK2
NC

COM

NO

GND

LOCK1
SEN

NC

COM

NO

NC

COM

AUXOUT3 AUXOUT4
NO

NC

COM

AUXOUT2
NO

NC

COM

AUXOUT1
NO

485+

PC
SGND

SWITCH

LAN

485-

r the World

GND

IN

+12V

GND

WD0

BUTTON 3

BUTTON 2

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

READER 1

GND

IN

+12V

GND

WD0

READER 1

WD1

GLED

BEEP

GND

IN

GRD

BUTTON 1

WD1

BEEP

BUTTON 1

GND

IN

GRD

ACT

RUN

485+

PWR

485-

GND

+12V

GND

IN

GND

IN

GND

STATE

GLED

ACT

RUN

PWR

485+

485-

GND
AUX 1

IN

EXT

GND

AUX4

+12V

IN

IN

GND

GND

Wiegand Card Reader

Figure 18

ND

EN

OM

OM

OM

OM

GND

85-

LO
EN

LOCK1
C

AUXOUT3 AUXOUT4

OM

AUXOUT2

AUXOUT1

ND

PC

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

85+

SWITCH

15

REX Connections
Separate Power Supply
12V DC(+)
12V DC( - )
BUTTON

No Touch

Unused

GND

COM

EXIT

PUSH

NO

ZK ABK Exit Button

AUX4

EXT

STATE

BUTTON 1

READER 1

BUTTON 2

READER 2

GLED

GND
IN
BEEP
GND

IN
+12V

GLED
BEEP
WD1
GLED
WD0
WD1
GND
WD0
+12V
GND

BEEP
GND

READER 3

BUTTON 4

CARD

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

BUTTON 3

PC
RS485

PCEXT
RS485
RS485

Best Security Solution for the World

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

GRD

ACT

RUN

PWR

485+

485-

GND

+12V

GND

IN

GND

IN

AUX 2 AUX 3

EXT
RS485

EXT
RS485

GND
IN

GLED
WD0
WD1
GND
WD0
+12V
GND
IN
+12V

BEEP
GND
GLED
BEEP
WD1

GND
IN

WD0
PWR
GND
RUN
+12V
ACT
IN
GRD

WD1

BEEP
485+
GLED

AUX 1

GND

READER 1STATE
BUTTON
BUTTON
2
1 READER
READER
2
BUTTON
1
BUTTON
3
2READER
READER
3
2BUTTON
BUTTON
4
3RE

IN

BUTTON
EXT 1

GND

+12V
IN
GND
GND
485-

STATE
AUX4

IN

RUN
IN
ACT
GND
GRD

K1-1 Exit Switch

READER 4

RUN

POWER

CARD PC
RUN CARD
A dRS485
v a nced A c c es s Con tr ol

e World
LOCK3

LOCK4

LOCK POWER
GND

+12V

V-

V+

NC

COM

NO

GND

SEN

NC

COM

NO

GND

SEN

NC

A d v a nced A c c
Aes
d

COM

NO

GND

SEN

LOCK2
NC

COM

NO

GND

LOCK1
SEN

NC

COM

NO

NC

COM

AUXOUT3 AUXOUT4
NO

NC

COM

AUXOUT2
NO

NC

COM

NO

AUXOUT1
SGND

PC
485-

SWITCH
485+

LAN

Figure 19

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

16

A d v a nced A c c es s C

Lock Connection

Connecting a Lock with External to Power Supply


(Dry Contac

IN

AUX 2 AUX 3

IN

AUX4

LOCK1
SWITCH

EXT

SEN

COM
NC

COM
NC

+12V
GND

LOCK PO

GND

IN
GND

GLED
WD1
WD0
GND

IN
GND

GLED
WD1
WD0
GND
+12V
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V

POWER

GND

Door Contact
Sensor
Sensor
GND

12V DC

Figure 20

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

FR107
Diode

V-

V+

NC

COM

NO

GND

SEN

NC

COM

NO

GND

SEN

NC

COM

NO

GND

NC

WD0

BEEP

READER 4

V-

LOCK POWER

V+

WD1

+12V

RUN

NO

LOCK4

GND

BUTTON 4

SEN

READER 3

NO

LOCK3

ETHERNET

GND

GLED

BUTTON 3

SEN

CARD

NC

A d v a nced A c c es s Con tr ol

COM

LOCK2

NO

LOCK4

BEEP

NC

GND

GND
BEEP

READER 2

COM

LOCK1

NO

BUTTON 2

SEN
GND

LOCK3

485-

IN

+12V
PC
RS485

NC

COM

NO

GND

SEN

NC

COM

COM

NO

NO

COM

GND

ACT

NC

NC

NO

GND

COM

NC

READER 1

COM

AUXOUT3 AUXOUT4

NO

LOCK2

IN

RUN
GRD

BUTTON 1

NC

EXT
RS485

COM

AUXOUT2

NO

GND

PWR
STATE

NC

AUXOUT1

NO

PC

COM

IN

485+

SGND
NO

GND

+12V

485+
485-

GND

SEN

AUXOUT3 AUXOUT4

AUX 1

LAN

Best Security Solution for the World

AUXOUT2

(Dry Contact)

READER 1

BUTTON

READER 2

The factory default jumper setting is set as dry mode. If you want to power the
lock from the panel, you must take the following steps:

BEEP

IN
GND

+12V

BUTTON
GND

WD0

WD1

GLED

READER

BEEP

IN
GND

+12V

GND

+12V
GND

TX
RX

BUTTON

WD0

IN
GND

Important Notes:

WD1

IN
GND

EXT
BUTTON
BUTTON
Switching
Dry Contact
toREADER
Wet Contact
GLED

EXT

BEEP

AUX 4

IN
GND

AUX 3

485485+

AUX 2

IN
GND

17

BUTTON

1
2
3
4
5

1
2
3
4
5

1. Take apart the cover of inBIO Panel. Push the tab inward (see figure 21)
2. Select the appropriate lock relay and find its jumpers
3. Take off the jumpers and change
to
4. Connect the lock as show in the diagram, (see figure 23 and 24)

Model Number inBIO 460

ACT

MA

Select one Relay

TX
RX

Back of inBIO-Panel

ON

AUXOUT2

LOCK1

MA

5 4 3 2 1
Default setting
1, 2 - 3, 4

5 4 3 2 1

5 4 3 2 1

Take off jumpers

Jumpers

Plug Jumpers
2, 3 - 4, 5

Figure 22
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

LOCK2

NC

COM

NO

GND

SEN

NC

COM

NO

AUXOUT4

GND

AUXOUT3

SEN

NO
COM

NC

NO
COM

NC

AUXOUT1

NO
COM
NC

PC

NC

Model Number inBIO 460

NO
COM

1 2 3 4 5 6 7 8

485+
485 -GND

Figure 21

READER 3

BUTTON 4

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

WD1

GLED

BEEP

GND

IN

+12V

GND

WD0

18

ADER
2 the World
BUTTON 3
tion for

READER 4

A d v a nced A c c es

Lock Connection

Normally Open Lock Powered From Lock Terminal


(Wet Contact)

GND

AUX4

SWITCH

BUTTON 2

IN

GND
IN

READER 2

BUTTON 3

READER 3

COM
BEEP
NC
GLED

GND
NO

+12V
SEN
IN
GND

LOCK4

WD0
COM
GND
NC

BEEP
SEN
GLED
GND
WD1
NO

LOCK3
GND
NC

IN

GND

LOCK2
GND
+12V
NO
IN
COM

IN

GND
BEEP
NO
GLED
COM

1
A d vEXT
a nced A cSTATE
c esBUTTON
s Con
trREADER
ol 1

AUX4

LOCK1

COM
+12V
NC
IN
SEN
GND

WD1
NC
WD0
NO
GND

BEEP
NO
GLED
COM

GRD
NO
IN
COM

ACT
NC

PWR
NO
RUN
COM

SGND

485-

485+

485-

GND

+12V

GND

AUXOUT3 AUXOUT4

AUX 2 AUX 3

IN

AUXOUT2

AUX 1

GND

AUXOUT1

LAN

AUX 3

PC

Best Security Solution for the World

IN

SWITCH

POWER

WD1
NC
WD0
SEN
GND

RUN

GND
NC

CARD

BUTTON 4

RE

GND
+12V

EXT

485+

GND
485485+

PC

485SGND

NC

NC
NO
COM

READER 2

SEN

COM
NC

+12V
GND

ADER
2 the World
BUTTON 3
tion for

READER 3

BUTTON 4

GLED
WD1
WD0
GND

IN
GND

GLED
WD1
WD0
GND
+12V
IN

12V DC
GND

GND
BEEP
GLED
WD1
WD0
GND
+12V

PC

FR107
Diode RUN

CARD

+12V

16 or 18 RS485
AWG shielded cable recommended
GND

WD0

GND

GND

+12V

V-

V+

WD1

NC

EXT
RS485

GLED

COM

LOCK POWER

BEEP

NO
GND

GND
IN

+12V

GND

NC

SEN

LOCK4

COM
WD0

WD1

NO

GND

GLED

SEN
BEEP

NC
GND

IN

COM

NO

+12V

GND

SEN
GND

READER 4

GND
12V DC

A d v a nced A c c es

Figure 23

Normally Closed Lock Powered From Lock Terminal


(Wet Contact)

GND
IN
GND

AUX4

IN
GND
+12V

EXT

GND
485485+

SGND

NC

NC
NO
COM

PC
RS485

NC
SEN

NC

COM
NC

+12V
GND

GND

GLED
WD1
WD0
GND

IN
GND

12V DC
GND

GLED
WD1
WD0
GND
+12V
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V

GND

+12V

V-

V+

LOCK POWER

NC

COM

NO

GND

SEN

LOCK4

NC

COM

NO

SEN

NC

COM

NO

GND

SEN

LOCK3

IN

POWER

LOCK2

GND

BEEP

READER 4

V-

LOCK POWER

V+

RUN

NO

LOCK4

GND

BUTTON 4

SEN

READER 3

COM

LOCK3

NO

CARD

SEN
GND

WD0

+12V

NC

A d v a nced A c c es s Con tr ol

COM

BUTTON 3

NO

LOCK2

GND

WD1

BEEP
READER 2

COM

LOCK1

NO

GND

+12V

SEN
GND

IN

GLED

BUTTON 2

NC

ACT

BEEP
READER 1

COM

AUXOUT3 AUXOUT4

ETHERNET

NO

RUN
GRD

BUTTON 1

NC

EXT
RS485

COM

AUXOUT2

NO

PWR
STATE

COM

AUXOUT1

NO

FR107
Diode

GND
12V DC

Figure 24
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

L
NC

COM

NO

GND

SEN

LOCK4
NC

COM

NO

GND

SEN

LOCK3
NC

COM

NO

GND

SEN

NC

COM

NO

LOCK2

PC

485-

LOCK1
SEN

AUX 2 AUX 3

IN

485+

GND

NC

IN

COM

AUX 1

SWITCH

Best Security Solution for the World

LAN

A d v a nced A c c es s Con tr ol

NO

NC

COM

NO

AUXOUT3 AUXOUT4

NC

AUXOUT2
COM

NC

COM

NO

AUXOUT1
SGND

485-

PC
485+

SWITCH

POWER

GND

RUN

NO

CARD

GND

WD0

LOCK3

IN

POWER

LOCK2

GND

BEEP

READER 4

V-

LOCK POWER

V+

RUN

NO

LOCK4

GND

BUTTON 4

SEN

READER 3

NC

BUTTON 3

COM

LOCK3

NO

CARD

SEN
GND

WD0

+12V

NC

A d v a nced A c c es s Con tr ol

COM

LOCK2

NO

WD1

BEEP

NC

GND

GND

+12V
BUTTON 2

COM

IN

GLED

LOCK1

NO

ACT

BEEP

SEN
GND

RUN
GRD

PC
RS485

NC

READER 1

COM

AUXOUT3 AUXOUT4

NO

BUTTON 1

NC

EXT
RS485

COM

AUXOUT2

NO

STATE

COM

ETHERNET

PWR

AUXOUT1

NO

19

Aux. I/O connection

NC
SEN

COM
NC

+12V
GND

READER 4

V-

LOCK POWER

V+

GND

GLED
WD1
WD0
GND

IN

GND

IN
GND
BEEP
GLED
WD1
WD0

EXT

EXT
RS485

485+

NC
SEN

IN

+12V

GND

WD0

GND

WD1

WD0
GND

NC

+12V

GND

IN
GND

GLED
WD1
WD0
GND

IN
GND

GLED
WD1
WD0

GLED
WD1
WD0
GND

GND

+12V

IN
GND
BEEP
GLED
WD1
WD0
GND
+12V

IN
GND

ALARM

BEEP
READER 3

GLED
WD1
WD0
GND

GND

+12V

READER 4

Figure 26

BUTTON 4

RUN

12V DC

IN
GND
BEEP
GLED
WD1
WD0
GND
+12V

POWER

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

COM

NO

GND

SEN

LOCK2
NC

COM

NO

GND

LOCK1
SEN

NC

COM

NO

NC

NO

NC

COM

COM

NO

NC

COM

NO

SGND

485-

WD0

POWER

CARD

GND

WD1

BUTTON 3

V-

READER 4

V+

RUN

COM

AUXOUT3 AUXOUT4

GND

GND

+12V
BUTTON 4

GND

NO

IN

BEEP
READER 3

+12V

LOCK POWER

V-

GND

CARD

NC
V+

SEN

ACT

+12V
BUTTON 3

LOCK4

COM

COM

LOCK POWER

SEN
NO

NO

LOCK4

NC

GND

GND

LOCK3

LOCK3

COM

SEN

A d v a nced A c c es s Con tr ol

SEN
NO

NC

NC

NC

GND

COM

LOCK2

COM

NO

A d v a nced A c c es s Con tr ol

ETHERNET

LOCK2

GND

NO

IN

BEEP

RUN

BEEP
READER 2

COM

485-

+12V

LOCK1

NO

GND

GLED

SEN
GND

GND

BEEP

PC
RS485

NC

GND

ACT

AUXOUT2
IN

GRD

BUTTON 2

NC

SEN

CAR

RUN

AUXOUT1

READER 2

COM

GND

BUTTON 2

NO

PC

IN

PWR

READER 1

NC

BUTTON 1

COM

AUXOUT3 AUXOUT4

NO

EXT
RS485

NC

GND

+12V

STATE

COM

AUXOUT2

NO

IN

EXT

NC

AUXOUT1

COM

AUX4

SGND
NO

IN

GND

485+

PC

485-

IN

AUX 2 AUX 3

485+

AUX 1

Best Security Solution for the World

PC
RS485

SWITCH

SWITCH

COM

WD1

PC
GND RS485
12V DC

+12V

LAN

LOCK1

NO

GLED

485-

GLED

SEN
GND

BEEP

GND

BEEP

LAN

NC

GND

GND

Aux. Output Connection

485+

COM

FIRE
ALARM

GRD

Figure 25

READER 1

NO

Best Security Solution for the World

BUTTON 1

NC

O TEST WE
HT

PWR
STATE

COM

AUXOUT3 AUXOUT4

NO

IN

IN

+12V

EXT
RS485

NC

+12V

GND

GND

POWER

COM

GND

IN
PUS

WD0

BUTTO

+12V

AUXOUT2

NO

AUXOUT1

NC

READER 2

LY
EK

WD1

PC

COM

BUTTON 2

GLED

SGND
NO

WD0

WD1

GLED

READER 1

GND

GND

485+
485-

BEEP

GND

IN

GRD

ACT

RUN

IN

+12V
RUN

NO

LOCK4

GND

GND

BEEP

BUTTON 4

SEN

WD0

PUS

NC

WD1

AUX4

COM

GND

+12V

READER 3

NO

LOCK3

GND

GND

LY
EK

SEN

CARD

SWITCH

NC

A d v a nced A c c es s Con tr ol

COM

BUTTON 3

NO

LOCK2

GND

IN

BEEP
READER 2

COM

IN

IN1
BUTTON

+12V

LOCK1

NO

ACT

GLED

SEN
GND

STATE

RUN

BEEP

BUTTON 2

NC

PC
RS485

ETHERNET

COM

PWR

485+

485-

GND

+12V

GND

IN

GND

IN

GND

IN

NO

485-

O TEST WE
HT

NC

GND

GRD

READER 1

COM

AUXOUT3 AUXOUT4

NO

GND

PWR

BUTTON 1

NC

EXT
RS485

COM

EXT

AUXOUT2

NO

GND

AUX 2 AUX 3

NC

STATE

COM

IN

+12V

EXT

GND

AUX4

IN

GND

485+

SGND
NO

GND

AUX 2 AUX 3

485-

AUXOUT1

AUX4

PC

AUX 2 AUX 3

IN

IN

485+

AUX 1

AUX 1

AUX 1

SWITCH

Best Security Solution for the World

LAN

Best Security Solution for the World

LAN

IN

Aux. Input Connection

20

Ethernet Connection
LAN Connection
Important Notes:

1. Both 10Base-T and 100Base-T are supported


2. This cable distance must be less than 330 ft. (100m)
3. For cable length of more than 330 ft. (100m). use HUB to amplify the signal.

GND
IN
GND

IN

IN

AUX4

SWITCH

GND

AUX 2 AUX 3

GND

AUX 1

AUX4

IN

Best Security Solution for the World

IN

LAN

AUX 2 AUX 3

SWITCH

AUX 1

Best Security Solution for the World

LAN

IN

+12V

485+

485+

GND
485-

COM

PC
RS485

GND
NO

GLED

COM

WD1

NC

WD0
GND

SEN

+12V

GND
COM

GND

NC
SEN
GND

WD1

NO

WD0

COM

GND

NC

NO

BEEP

COM

GLED

NC

WD1

V+

WD0

V-

GND

+12V

+12V

GND

GND

IN
GND

GLED
WD1
WD0
GND

IN
GND
BEEP
GLED
WD1
WD0
GND
+12V

READER 4

GND

WD0

+12V

RUN

GND

BUTTON 4

SEN

IN

READER 3

GLED

CARD

IN

BUTTON 3

NO

WD1

BEEP
READER 2

BEEP

GND

+12V

SEN

GND

IN

GLED

BUTTON 2

NC

IN

ACT

BEEP
READER 1

NO

+12V

LOCK POWER

GND

GND

LOCK4

+12V

READER 4

V-

LOCK POWER

V+

RUN

NC

NC

WD0

+12V
BUTTON 4

COM

LOCK4

NO

GND

RUN
GRD

BUTTON 1

NC

GND

IN

485+

LOCK3

COM

WD1

BEEP
READER 3

NO

LOCK3

GND

COM

EXT
RS485

SEN

NO

GLED

IN
GND
BEEP
GLED
WD1
WD0
GND
+12V

POWER

POWER

A d v a nced A c c es s Con tr ol

NC

CARD

COM

BUTTON 3

NO

NC

BEEP

LOCK2

GND

COM

GND

LOCK1

SEN

SEN

CR10 Card Issuer

READER 2

NC

A d v a nced A c c es s Con tr ol

USB

COM

LOCK2

USB

NO

LOCK1

GND

NO

IN

STATE

SEN

BUTTON 2

PC
RS485

NC

GND

PWR

AUXOUT3 AUXOUT4

COM

NC

AUXOUT2

NO

ETHERNET

COM

ACT

AUXOUT1

NC

READER 1

COM

AUXOUT3 AUXOUT4

NO

NO

RUN
GRD

BUTTON 1

NC

EXT
RS485

COM

AUXOUT2

NO

PWR
STATE

NC

IN

SGND
AUXOUT1

COM

GND

PC

485-

SGND
NO

GND

+12V

485-

PC

485-

EXT

EXT

485+

GND

CAT5e or CAT6 ethernet


cable recommended

ZK4500 Enrollment reader


Figure 27

Direct connection
To connect inBIO-Panel with a PC directly, connect both devices with a straight
network cable. As the inBIO-Panel supports auto MDI/MDIX, it is not necessary to
use a crossover type cable.
AUX 1

IN

AUX 2 AUX 3

LAN

IN

SWITCH

AUX4

Best Security Solution for the World

ETHERNET

GND

GND
IN
GND
IN
GND
+12V

EXT

485+

GND
485485+

PC

485SGND

NC

NC
NO
COM

PC
RS485

NC
SEN

SEN

NC

NO
COM
NC

+12V
GND

ZK4500 Enrollment reader

Figure 28
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

IN
GND

GLED
WD1
WD0
GND

IN
GND

GLED
WD1
WD0
GND
+12V
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V

POWER

CR10 Card Issuer

GND

BEEP

READER 4

V-

LOCK POWER

V+

WD0

+12V

RUN

GND

BUTTON 4

SEN

READER 3

COM

LOCK4

USB

NO

LOCK3

USB

GND

CARD

NC

A d v a nced A c c es s Con tr ol

COM

BUTTON 3

NO

LOCK2

GND

WD1

BEEP
READER 2

COM

LOCK1

NO

GND

+12V

SEN
GND

IN

GLED

BUTTON 2

NC

ACT

BEEP
READER 1

COM

AUXOUT3 AUXOUT4

NO

RUN
GRD

BUTTON 1

NC

EXT
RS485

COM

AUXOUT2

NO

PWR
STATE

COM

AUXOUT1

NO

RS

PC

TX
RX

ACT

NO
SEN
COM
GND
NC
NO
485+
COM
NO
485-COM
NC
GND
NC
SEN
NO
GND
COM
NO
NO
NC
COM
COM
NC
SEN
NC
GND
NO
SEN
NO
COM

NO
NO
COM
COM
NC

1 2 3 4 5 6 7 8

NC

AUXOUT2
PC

NC

AUXOUT1

1 2 3 4 5 6 7 8

GND
NO
COM

ON

NO
COM
485+
NC
485--

6 7 8

NO
COM
NC

ON

RS485
-1 2 3 4 5
RS485 +
GND

485+
485-GND

ON

TX
RX

TX
RX

ACT

LINK

ACT

LINK

RS485 Connection

LINK

21

AUXOUT3 AUXOUT1
AUXOUT4 AUXOUT2
LOCK1 AUXOUT3
PC

AUXOUT4
LOCK2
AUXOUT1

LOCK1
AUXOU

485

#1 inBIO-Panel

#2 inBIO-Panel

#63 inBIO-Panel

Figure 29

Important Notes:

1. RS485 communication wires should be a shielded twisted pair cable. RS485


IN
GND

IN
GND

IN
+12V
GND

485IN
485+
GND

IN
GND

IN
GND

AUX
READER
2
AUX 3

AUX
BUTTON
BUTTON
4
EXT

READER
EXT
READER

BUTTON
BUTTON BUTTON
READ
RE
GND
GLED
WD1

IN
GND

EXT
BUTTON
AUXEXT
1

BEEP
BEEP
GLED
IN

AUX 4

+12V
IN
GND
IN
GND

AUX 3

WD0
GND
GND
+12V

AUX
EXT 2

GLED
WD1
485485+
WD1
WD0

AUX
EXT 1

IN
IN
GND
GND
IN
GND
+12V
BEEP
GND
BEEP
GLED

AUX 4

WD0
IN
GND
GND
+12V

AUX 3

GLED
IN
GND
WD1

AUX 2

+12V
IN
GND
GND
IN
485GND
BEEP
485+

AUX 1

IN
GND

communication wires should be connected in a bus cascade topology instead


of a star topology, to achieve a better shielding effect by reducing signal
reflection during communications.

2. A single RS485 bus can connect up to 63 access control panels, but preferably
BUTTON
BUTTON

READER
READER
2 1

BUTTON
BUTTON BUTTON
READE
READ

TX
RX

READER 1

TX
RX

TX
RX

BUTTON

32 is recommended maximum.

3. To eliminate signal attenuation in communication cables and suppress inter-

TX
RX

BUTTON

READER 1

ON

BUTTON
BUTTON

READER
READER
2 1

GND
GLED
WD1

BEEP
BEEP
GLED
IN

+12V
IN
GND
IN
GND

BUTTON
BUTTON BUTTON
READ
RE

WD0
GND
GND
+12V

READER
EXT
READER
GLED
WD1
485485+
WD1
WD0

AUX
BUTTON
BUTTON
4
EXT

BUTTON
BUTTON BUTTON
READE
READ

TX
RX

AUX
READER
2
AUX 3

IN
IN
GND
GND
IN
GND
+12V
BEEP
GND
BEEP
GLED

IN
GND

ON

EXT
BUTTON
AUXEXT
1

WD0
IN
GND
GND
+12V

AUX 4

GLED
IN
GND
WD1

AUX 3

+12V
IN
GND
GND
IN
485GND
BEEP
485+

AUX
EXT 2

IN
GND

IN
GND

AUX
EXT 1

485IN
485+
GND

IN
GND

AUX 4

TX
RX

AUX 3

IN
+12V
GND

AUX 2

IN
GND

AUX 1

IN
GND

ference, if the bus is longer than 200 meters, set the number 8 DIP switch to
the ON position. This is equivalent to a parallel connection of one 120 ohm
resistance between the 485+ and 485- lines.
Distance: More than 200 meters

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

SINGLE inBIO-Panel

MULTI inBIO-Panel

PC

TX
RX

NO
SEN
COM
GND
NC
NO
485+
COM
NO
485 -COM
NC
GND
NC
SEN
NO
GND
COM
NO
NO
NC
COM
COM
NC
SEN
NC
GND
NO
SEN
NO
COM
AUXOUT4
LOCK2
AUXOUT1

LOCK1
AUXOU

NC

TX
RX

ACT
TX
RX

TX
RX

PC

NO
SEN
COM
GND
NC
NO
485+
COM
NO
485 -COM
NC
GND
NC
SEN
NO
GND
COM
NO
NO
NC
COM
COM
NC
SEN
NC
GND
NO
SEN
NO
COM

1 2 3 4 5 6 7 8

NC

AUXOUT2
PC

NO
NO
COM
COM
NC

AUXOUT1

1 2 3 4 5 6 7 8

NC

NO
COM
485+
NC
485 --

ON

NO
COM
NC

6 7 8

485+
485 -GND

ON

RS485
-1 2 3 4 5
RS485 +
GND

#63 inBIO-Panel

LINK

#2 inBIO-Panel

ACT

LINK

ACT

LINK

ON

RS

1 2 3 4 5 6 7 8

AUXOUT3 AUXOUT1
AUXOUT4 AUXOUT2
LOCK1 AUXOUT3
PC

485

#1 inBIO-Panel

NO
NO
COM
COM
NC

AUXOUT2
PC

NC

AUXOUT1

GND
NO
COM

NO
COM
485+
NC
485 --

ON

1 2 3 4 5 6 7 8

GND
NO
COM

RS

6 7 8

NO
COM
NC

ON

RS485
-1 2 3 4 5
RS485 +
GND

485+
485 -GND

ON

TX
RX

ACT

LINK

ACT
TX
RX

ACT

LINK

Incorrect RS 485 connections

LINK

Figure 30

AUXOUT3 AUXOUT1
AUXOUT4 AUXOUT2
LOCK1 AUXOUT3
PC

AUXOUT4
LOCK2
AUXOUT1

485

#1 inBIO-Panel

#2 inBIO-Panel

#63 inBIO-Panel

Figure 31
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

LOCK1
AUXOU

RS485 Connection

16
32
Restore Factory Setting
RS485 Terminal Resistance

2 3 4 5 6 7 8

12345678

O
N 1

ON

1 2 3 4 5 6 7 8

22

Figure 32

Restore factory setting


1. If you forget the IP address of the inBIO panel or the device does not work normally, you can use the number 7 DIP switch to restore inBIO-Panel to factory
default settings. The parameters which gets reset are device IP address,
communication password, gateway, and subnet mask.

2. The switch is OFF by default. When it is moved up and down for three times

within 10 seconds and finally returned to OFF position, the factory settings will
be restored after the access control panel is restarted.

ON

To reset factory settings


Turn #7 switch ON and OFF

ON ON
OFF

OFF

1 2 3 4 51 62 73 84 5 1 6 2 7 3 8 4 5 6 7 8

Figure 33

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

Repeat process 3 times

23

DIP Switch Setting


RS485 Address
1. Number 1-6 are reserved to set the device number for RS485 communica-

tion. The code is binary, and the numbering starts from left to right. When the
switch is set to ON position, it indicates 1 (on); when the switch is set downwards, it indicates 0 (off ). For example, to set a device number 39=1+2+4+32,
which corresponds to the binary code 111001, put number 1, 2, 3, and 6 to ON
position, as illustrated below.

ON

ON
AUX 2

AUX 3

AUX 4

EXT

EXT

IN
GND

IN
GND

+12V
GND

485485+

BUTTON

TX
RX

Figure 34

BUTTON
IN
GND

AUX 1

IN
GND

1 2 3 4 5 6 7 8
IN
GND

1 2 3 4 5 6 7 8

For more details, please check the table at the end of this document.

Terminal Resistance
1. Number 8 is for setting the RS485 termination resistance. Putting the switch

TX
RX

ACT

LINK

to ON position is equivalent to parallel connection of a 120 ohm termination


resistance between 485+ and 485- lines.

PC

ON

1 2 3 4 5 6 7 8

120 ohm

#63 inBIO-Panel
Figure 35

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

AUXOUT1

NC

NO
COM

NC

NO
COM

GND

1 2 3 4 5 6 7 8

485+
485--

ON

AUXOUT2

24

Installation Diagram
Ethernet Communication wire

RS485 Network Communication wire

220/110 V Input

inBIO Access Control Bundle

CEILING

Sensor

Electric Lock

OUTDOOR

INDOOR

Exit Button

Outdoor Wiegand card reader

Indoor Wiegand card reader

Figure 36
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

25

Troubleshooting
1. How to switch four door one way to two door two way?
Connect four readers from reader 1 to reader 4.
Connect two door locks, one connected to LOCK1, another connected to LOCK3.
In the software configure reader 1-Indoor, and reader 2-Outdoor.
Access Control Panel Type:

One-Door Access Control Panel


Two-Door Access Control Panel
Four- Door Access Cotrol Panel
Access Control Devices

Add

Switch to Two-Door Two way:


Figure 34

2. Can we integrate IP Camera and NVR?


Currently ZKACCESS software supports ZKAccess IP Cameras and NVR
You can associate a camera to the door and setup a linkage for the same.

3. What does it mean when I get a Wiegand Format Error?


Your WD0 and WD1 wiring is reversed.

4. How do I connect a third party reader or a stand-alone reader to a


inBIO panel?
Connect the wiegand output to the WD0 and WD1 of the stand-alone readers on the
panels reader port.
Note: The board can only supply 12 V DC, 300mA power so an external power supply may be required.

5. What is the SD card slot used for?


SD card, stores transactions from the panel and creates a back up in additional to
internal memory.

6. What kind of wire is recommended for the panel?


16 or 18 AWG twisted shielded wire is recommended.

7. What is the default IP of the panel?


192.168.1.201

8. How long is the device under warranty?


1 Year from original purchase date, replacement/repair of hardware under ZK standard
warranty requires an evaluation of the failed system by a ZK Technical Support specialist,
and the issuance of a Technical Support RMA number.

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

26

PC 485 Setting Table


Switch Setting
Address No.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

16

32

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

ON

OFF

ON

OFF

ON

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

ON

ON

OFF

ON

ON

OFF

ON

ON

OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

ON

ON

ON

OFF

OFF

ON

ON

ON

ON

OFF

ON

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

27

Switch Setting
Address No.
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63

16

32

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

ON

ON

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

ON

ON

OFF

ON

OFF

ON

OFF

OFF

ON

ON

OFF

ON

ON

OFF

ON

ON

OFF

ON

OFF

ON

ON

ON

OFF

ON

ON

ON

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

ON

ON

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

ON

ON

ON

OFF

ON

OFF

ON

ON

OFF

ON

ON

OFF

ON

ON

ON

ON

ON

OFF

ON

ON

OFF

OFF

OFF

ON

ON

ON

ON

OFF

OFF

ON

ON

ON

OFF

ON

OFF

ON

ON

ON

ON

ON

OFF

ON

ON

ON

OFF

OFF

ON

ON

ON

ON

ON

OFF

ON

ON

ON

ON

OFF

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

28

Electrical Specifications
Maximum

Typical

Minimum

Notes

WORKING POWER SUPPLY


Voltage (V) DC

9.6

12

Current (A)

14.4

Use regulated DC power adaptor only

ELECTRONIC LOCK RELAY OUTPUT


Switching voltage (V)

12V

Switching Current (A)

Use regulated DC power adaptor only

Auxiliary relay output

SWITCH AUX. INPUT


VIH (V)
VIL (V)
Pull-up resistance ()

The input ports are pulled up with 4.7k


resistors

4.7k

WIEGAND INPUT
Voltage (V)

10.8

12

Current (mA)

13.5
500

ZK ELECTRIC LOCK
Voltage (V) DC
Current (mA)

10.8

12

13.2
500

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

29

Specifications
Communication

RS485, TCP/IP

Baud Rate for RS485

9600-15200

Power Supply

12V DC, 2A

Card Holders Capacity

30,000

Log Events Capacity

100,000

LED Indicator

Indicator for communication, power, status and prox card

Environment

32-113 F (0-45C)

Operating Humidity

20% to 80%

Number of doors controlled

Four Door (four door one way and two door two way)

Number of readers supported

Types of readers supported

26-bits WIEGAND, others upon request

Number of Inputs

12 (4 Exit Device, 4 Door Status, 4 AUX)

Number of Outputs

8 (4- Form C relay for lock and 4- Form C relay for Aux output)

Weight

7.8lbs (3.55kg)

Enclosure

Metal Cabinet

Mounting

Wall Mount

Dimensions (Bundle Only)

15.7in. x 3.56in. x 13.0in 400mm(L) x 90.5mm(W) x 330mm(H)

Dimensions (Board Only)

8.0in. x 4.17in. 203.2mm(L) x 106mm(W)

CPU

32 bit 400MHz

RAM

32MB

Flash

128MB

Certified

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

30

ZKAccess 5.2 software

Installation & Setup


Content

Downloading..................................................................................................................31
Installation.........................................................................................................................32
Adding a Device...........................................................................................................33
Creating a Time Zone. . ..............................................................................................34
Create an Access Level.............................................................................................35
Enrolling Personnel. . ................................................................................................. 36
Add & Delete Personnel to Access Level....................................................38
Real Time Monitoring. . ..............................................................................................39
Exporting Reports. . ......................................................................................................40
Passage Mode / First Card Normal Open ..................................................41

31

Downloading

1. Go to zkaccess.com.
2. Click Downloads and then Software Downloads in the dropdown menu.

3. Scroll to the bottom of the page and click ZKACCESS 5.2.22 to download.
If you do not have software to extract compressed files, Scroll up on the
same page to find Winrar 32 or Winrar 64 to download.

4. Extract the downloaded files to a new folder named ZKAccessSetup


5. Click setup.exe to
begin installation.

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

32

Installation

1
2

1. Add an open port (Default 80) or ask a network administrator for an open port
2. Click the box to Add firewall exception for this port

4
3

3. Click Browse and choose or create a folder to store your backup files in.
4. Click OK

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

33

Adding a Device
1
3

1. Click Device
2. Click Search Panels , to show the Search interface;
3. Click Search , and it will prompt [searching];

7
5

4. After searching, the list of all access control panels on the network
will be displayed.

5. Click Add Device on the right side of the listed device, and a dialog box will open.
6. Enter self-defined device name, and
click OK to complete the process.

The default IP address of the access


control panel may conflict with the IP of
another device on the network.

7. You can modify the IP address: Click


Modify IP Address to the right of
the device and a dialog box will
open. Enter the new IP address and
other parameters

Note: Must configure the gateway and IP address in the


same network segment

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

34

Creating a Time Zone

1. Click Access Control > Time zones > Add to access the time zone
setting interface

2. After setting the time zone, click OK to save, and the time zone will appear
in the list.

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

35

Create an Access Level

1. Click Access Control > Access levels > Add to add an access level.

2. Set parameters: access level name (no repetition), access control time zone,
door combination

3. Click OK to complete setting and quit, and added access levels will appear in
the list.

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

36

Enrolling Personnel

1. Click Personnel > Personnel > Add to show personnel profile edit interface.

3
4
5
6

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

37

2. Personnel No.: By default, the length can not exceed 9 digits A number with a
length of less than 9 digits will be preceded with 0 automatically to complete
9 digits. Numbers can not be duplicated.

3. Card number: You can add a card number through manual entry or a card issuer.
In Actual Card Number mode (by default), you must enter both the actual card
number and the site code, then the software converts the numbers to the
internal card number for access control system verification. In Internal Card
Number mode, enter the numbers directly.

4. Password: Set personnel password to use on a keypad reader. Password must


be 4 to 6 numbers long.

5. Department: Select from the pull-down menu and click OK . If the department

was not set previously, you can only select the default Company Name department.

6. Register Fingerprint: Enroll the Personnel Fingerprint or Duress Fingerprint.

If the person presses the Duress Fingerprint, it will trigger the alarm and send
the signal to the system.

7. Access Level: Click the box next to the access level you would like to add the
personnel to. (Optional)

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

38

Add & Delete Personnel to Access Level


1

1
3
3

1. Click Access Control > Personnel Access Levels to show current access levels
and personnel. Click Add personnel to open the add personnel interface.

2
2

2. Select personnel to create the list on the right, and click OK to complete
adding, and added personnel will appear in the list on the right.

3. To delete personnel, select personnel and click Delete from access level .

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

39

Real Time Monitoring


1
2
3

1. Click Access Control > Real-Time Monitoring to watch a live log of


device transactions.

2. Click the Filters to limit which device transactions show up or view all
devices at once.

3. Hover over a door icon to open pop up menu and click Remote Close ,
Remote Open , or Cancel Alarms .

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

40

Exporting Reports
1

1. Click Access Control > Reports to see a report of transactions from devices.
2. Filter by time, date, personnel, or device.
3. Click Export Report to open export menu.

4. Choose a file type and click Export .

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

41

Passage Mode / First Card Normal Open

The Passage Mode feature will keep a door unlocked during a specified time
zone. It will automatically unlock at the beginning of the time zone and will lock
automatically at the end of the specified time zone.

1. Create a new time zone with the hours you want the door to be unlocked.
2. In Door Configuration, Click Edit to the right of the door you want to change
settings on.

3. Click the dropdown menu titled Door Passage Mode Time Zone and select
your new time zone. Click OK .

The First Card Normal Open feature will keep a door unlocked during a specified
time zone when triggered by specified personnel. After a specified personnel
swipe unlock at the beginning of the time zone and will lock automatically at the
end of the specified time zone.

1. Create a new time zone with the hours you want the door to be unlocked.
2. In Door Configuration, under First-Card Normal Open, click Set .
3. Under First-Card Normal Open Settings, click Add .
4. Click the drop down menu titled Time Zones and choose your new time zone.
Click OK .

5. To add the personnel that will trigger the door to stay normal open, click
Add an opening person .

6. Click the check box next to the personnel and they will be added to the Selected Personnel list. Click OK .

Design and Specifications subject to change without notice. 2014 ZKTeco and its subsidiaries.
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

42

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

43

inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE

Version: March 2015

ZKAccess - a division of ZKTeco