Anda di halaman 1dari 11

PART IV (a) :WEIGHT OF 66kV M/C TOWERS & BODY EXTENSIONS IN KG

(Of M/s. C.P.R.I. Design)


66kV M/C
TYPE MA
Super
Bolt &
Structure
Nuts

Sl.
No
1

Normal
Tower
+3M
Extn
.only
+6M
Extn
only
Stub

66kV M/C
TYPE MB
Super
Bolt &
Structur
Nuts

66kV M/C
TYPE MC
Super
Bolt &
Structur
Nuts

66kV M/C
TYPE MD
Super
Bolt &
Structur
Nuts

4178

256

6794

250

8688

346

556

29

1054

31

1317

39

1200

57

2223

68

2664

91

298

559

712

10

WEIGHT OF 110 kV M/C TOWERS & BODY EXTENSIONS IN KG


(Of
110kV M/C
TYPE MA
Super
Bolt &
Structure. Nuts

Sl
N

Normal
Tower
+3M
Extn.
only
+6M
Extn
only
Stub

M/s. C.P.R.I. Design)


110kV
TYPE
Super
Structur

M/C
MB
Bolt &
Nuts

110kV M/C
TYPE MC
Super
Bolt &
Structure. Nuts

110kV M/C
TYPE MD
Super
Bolt &
Structure. Nuts

12403

422

17280

512

1543

45

2013

49

6901

312

864

33

1737

68

2901

96

3750

105

362

817

1040

11

WEIGHT OF 220 kV M/C TOWERS & BODY EXTENSIONS


(of M/s. K.Ramchandra Raos Design)
220kV M/C
TYPE MA
Super
Bolt &
Structure. Nuts

Sl.
No.
1

Normal
Tower

8289

312

220kV M/C
TYPE MB
Super
Bolt &
Structure
Nut
14514

765

220KV
TYPE
Super
Structur

M/C
MC
Bolt &
Nuts

220kV M/C
TYPE MD
Super
Bolt &
Structure Nuts

25732

754

+3M
Extn.
only
+6M
Extn
only

S4 Stub

681

44

1664

100

560

2830

98

4536

155

733

11

1364

17

PART IV (a)

WEIGHT OF 220Kv/110kV M/C TOWERS (of M/s.L&T Design)

Sl.
No.
Nor
mal
1
Towe
r
+3M
2 Extn
only
+6M
3 Extn
only
S 4 Stub

220/110KV
M/C TYPE
MA
Super
Bolt &
Structure Nuts

220/110KV
M/C TYPE
MB
Super
Bolt
Structur & Nut

5624

310

9228

4 72

756

31

1094

45

1036

39

1904

200

354

220/110KV
M/C TYPE
MB
Super
Bolt &
Structur Nuts
10700

220/110kV
M/C TYPE
MD
Super
Bolt &
Structure Nuts

484

12310

500

1257

55

1584

62

74

2302

88

2626

84

406

503

WEIGHT OF 220Kv/66kV M/C TOWERS (of M/s.C.P.R.I.Dgn)

Sl.
No.
Nor
mal
1
Towe
r
+3M
2 Extn.
only
+6M
3 Extn
only
S 4 Stub

220/66KV
M/C TYPE
MA
Super
Bolt &
Structure Nuts

220/66KV
M/C TYPE
MB
Super
Bolt
Structur & Nut

220/66KV
M/C TYPE
MB
Super
Bolt &
Structur Nuts

9372

332

17303

1031

34

2120

81

637

220/66Kv
M/C TYPE
MD
Super
Bolt &
Structure Nuts

622

31110

1191

1996

90

3529

144

3587

132

6257

223

1025

12

2340

54

PART IV (a)

WEIGHT OF 220Kv D/C NARROW BASE TOWER.


(of M/s. L&T Design adopted for NRS-Laggere line)

Sl.
No.
Normal
Tower
+3M
2 Extn.
only
+6M
3 Extn
only
1

S4 Stub

220KV
TYPE
Super
Structure

D/C
DA
Bolt
Nuts

&

220kV D/C
TYPE DB & DE
Super
Bolt
&
Structur
Nut

5814

272

10677

404

678

30

1375

55

2346

74

761

1370

PART IV (b) FOUNDATION VOLUMES FOR 66KV M/C TOWERS

(Common for Normal, +3M, & +6M Body Extension Towers)


Type of Soil/

Tower

Foundation

Type

Fully
Sub-Merged
Wet
Black Cotton
Dry

in Kg/Twr.

1.2
2.05
2.9

90
150
205

760
1612
2332

20.3
40.0

2.04
4.04

150
280

1120
2700

MD

54 .0

5.4

365

4584

MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD
MA

25.0
45.08
54.0
30.08
44.28
54.0
30.7
52.76
71.21
20.0

2.75
4.60
5.4
3.2
4.6
5.4
3.2
5.4
7.2
2.05

183
315
364
222
315
364
222
365
476
165

1284
3136
4324
1444
3136
4452
1496
3728
5816
1132

MC

Sub-Merged

in CMT/Twr

11.5
21.0
29.9

MA

DRY

Partially

Steel Re inf

1:3:6

MB

WET

in CMT/Twr

Earth Exvn.

1:2:4

Normal

Normal

Concrete Mix.

MD
MA
MB
MC

Fissured Rock

Submerged
Fissured Rock

MB
MC
MD

39.0
50.08

4.04
5.4

215
292

2828
4452

MA
MB
MC
MD

30.7
45.08
58.01

3.2
4.6
5.8

170
250
316

1440
3136
4548

PART IV (b) :FOUNDATION VOLUMES FOR 110KV M/C TOWERS

(Common for Normal, +3M, & +6M Body Extension Towers)


Type of Soil/

Tower

Foundation

Type

Normal
DRY

Normal
WET
Partially
Sub-Merged
Fully
Sub-Merged
Wet
Black Cotton
Dry
Fissured Rock
Submerged
Fissured Rock

Concrete Mix.
in CMT/Twr

Earth Exvn.

Steel Re inf

in CMT/Twr

in Kg/Twr.

95
225

836
2856

MA
MB
MC

1:2:4
12.0
32.8

1:3:6
1.3
3.2

MD

43.0

4.0

270

4148

MA
MB
MC

24.6
58.9

2.5
6.0

175
390

1300
5100

MD

84.6

7.7

510

8384

MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD

28.4
66.7
86.0
33.2
75.0
105.0
33.8
76.0
96.5
24.2
58.0
76.0
33.8
76.0
96.5

2.9
6.8
8.7
3.6
7.7
10.0
3.6
7.7
10.0
2.5
6.0
7.7
3.6
7.7
10.0

205
450
575
245
510
640
245
510
640
130
320
425
185
425
545

1388
5832
8676
1544
6224
9080
1604
6468
9788
1252
4872
8032
1608
6192
9972

PART IV (b): FOUNDATION VOLUMES FOR 220KV/110kV M/C

TOWERS
(Common for Normal, +3M, & +6M Body Extension Towers)

Type of Soil/

Tower

Foundation

Type

Normal
DRY

Normal
WET
Partially
Sub-Merged
Fully
Sub-Merged
Wet
Black Cotton
Dry
Fissured Rock
Submerged
Fissured Rock

Concrete Mix.
in CMT/Twr

Earth Exvn.

Steel Re inf

in CMT/Twr

in Kg/Twr.

39.0
101
125

82
707
935

MA
MB
MC

1:2:4
3.53
9.2
12.14

1:3:6
0.4
1.35
1.74

MD

16.93

2.45

173

1390

MA
MB
MC

MD

MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD

12.14
20.64
28.0
36.47
17.2
28.89
36.9
44.96
6.12
12.93
16.77
23.08
22.7
31.29
36.74
48.12

1.51
3.36
4.05
5.2
1.68
4.23
5.0
6.5
0.76
2.05
2.52
3.36
2.05
4.61
5.41
6.96

112
232
276
350
123
288
337
432
33
101
127
173
101
243
288
376

82
1688
1888
2849
82
1559
1968
3258
82
965
1291
1778
82
1654
2246
3513

PART IV (b):

FOUNDATION VOLUMES FOR 220KV/66kV M/C TOWERS


(Common for Normal, +3M, & +6M Body Extension Towers)
Type of Soil/

Tower

Foundation

Type

Normal

MA
MB

Concrete Mix.
in CMT/Twr
1:2:4
100.5
-

1:3:6
12.1
-

Earth Exvn.

Steel Re inf

in CMT/Twr

in Kg/Twr.

383
-

6930
-

MC

395.0

32.4

1005

31804

DRY

MD

491.0

40.0

1236

57521

Normal

MA
MB
MC

160.15
486.0

19.6
40.0

613.5
1236

14073
38828

MD

646.0

53.0

1629

67899

MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD

160.15
486.0
646.0
160.15
486.0
646.0
160.15
587.0
646.0
118.5
395.0
491.0
160.15
486.0
646.0

19.6
-

613.5
1236
1629
613.5
1236
1629
613.5
1492
1629
417.1
953
1180
570
1180
1564

14073
38828
67899
14073
38828
67899
14073
51348
67899
10370
33927
57520
14646
38828
67899

WET
Partially
Sub-Merged
Fully
Sub-Merged
Wet
Black Cotton
Dry
Fissured Rock
Submerged
Fissured Rock

40.0
53.0
19.6
40.0
53.0
19.6
48.4
53.0
14.4
32.4
40.0
19.6
40.0
53.0

PART IV (b):

FOUNDATION VOLUMES FOR 220KV M/C TOWER


(Common for Normal, +3M, & +6M Body Extension Towers)
Type of Soil/

Tower

Foundation

Type

Normal
DRY
Normal
WET

Concrete Mix.
in CMT/Twr

Earth Exvn.

Steel Re inf

in CMT/Twr

in Kg/Twr.

MA
MB
MC

1:2:4
-

1:3:6
-

MD

MA
MB
MC

2.244
5.1
-

17.16
47.96

191.8
401
-

1887
4916
-

Partially
Sub-Merged
Fully
Sub-Merged
Wet
Black Cotton
Dry
Fissured Rock
Submerged
Fissured Rock

MD

MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC
MD
MA
MB
MC

2.82
6.73
145.96
2.8
3.2
-

20.24
61.06

236.2
521.0
-

2057
6167
-

933
98.1
190.9
-

11225
1508
3602
-

MD

40.1

5.0

273

6190

MA
MB
MC
MD

95.6

637

9030

12.0
14.95
35.5

10.36

PART IV (b):

FOUNDATION VOLUMES FOR 220KV

D/C N.B. TOWERS

[M/s L&T design adopted in NRS- Leggere line]


(Common for Normal, +3M, & +6M Body Extension Towers)

Type of Soil/

Tower

Foundation

Type

Concrete Mix.
in CMT/Twr

Earth Exvn.

Steel Re inf

in CMT/Twr

in Kg/Twr.

1:2:4

1:3:6

DA

27

1.8

142

988

DB & DE

67.43

4.14

343

2482

DA

34.7

2.45

199

1275

DB & DE

Soft Rock

Wet Soft Rock

DA

DB & DE

65.93

93.26

3141

Hard Rock

Anda mungkin juga menyukai