Circuito
Descripcin
Pos.
1
LUMINARIAS GENERAL
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
MODELO:
NQ442B225
MARCA:
SQUARE D
MONTAJE:
SUPERFICIAL
Pgina 1
T17.1
VOLTAJE
DISYUNTOR
Carga (VA)
Polos
AMP
Modelo
120
112
20
QOB
120
81
20
QOB
VOLTAJE:
120/208
MATERIAL
POLOS:
42
BARRAS:
225 A
ALUMINIO
B/T:
SI
3F
B/N:
100%
0
0
0
0
0
0
0
0
HILOS:
Pgina 2
T17.1
CABLE (AWG)
CANALIZACION
Fases
Neutro
Tierra
(MM)
12
12
12
13
12
12
12
13
DISYUNTOR PRINCIPAL:
ALIMENT PROCEDE:
POLOS
MOD.
AMP
LA34225MC
225
Pgina 3
MEDIDOR
UBICACIN:
T17.1
TL01
CANALIZACION
Tipo
FACTORES DE DISEO
F.de D.
CARGA (VA)
L1
L2
2400
EMT
0.5
1.00%
EMT
0.3
1.00%
1012
0
0
0
0
0
0
0
0
0
0
0
0
ALIMENT PROCEDE:
POT. INSTALADA:
2400
1012
MEDIDOR
POT. DEMANDA:
720
506
FACTOR DE DEMANDA:
0.30
0.50
LOCAL 1
Pgina 4
T17.1
TL01
RGA (VA)
FACTORES DE DISEO
L3
CANALIZACION
F.de D.
Tipo
(MM)
1.00%
0.3
EMT
13
1.00%
0.5
EMT
13
81
0
81
PREV:
24
F.U.:
0.30
TOTAL:
3500
CORRIENTE FASE A:
0.8
CORRIENTE FASE B:
5594.4
CORRIENTE FASE C:
Pgina 5
T17.1
CABLE (AWG)
DISYUNTOR
Tierra
Neutro
Fases
Modelo
AMP
12
12
12
QOB
20
12
12
12
QOB
20
4.22
Fases
Neutro
Tierra
0.20
250 MCM
4/0
1/0
6.00
Pgina 6
T17.1
SYUNTOR
VOLTAJE
Carga (VA)
120
2400
120
900
Polos
ALIMENTADOR
(MM)
MATERIAL
RUTA
63
AL. 8000
SUB
Pgina 7
T17.1
Descripcin
Pos.
Circuito
TOMAC. EXTERNO
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
DOR
CANALIZACION TIPO:
LONG.
CORRUGADA
40
Pgina 8
CAIDA TENSION
3%
T17.1
POTENCIA INST
POTENCIA DEMAND
FASE A
FASE B
CORRIENTE In
FASE C
2400
720
1012
506
81
CORRIENTE Id
20
8.43333
24.3
0.675
2400
1012
0.675
81
720
506
24.3
Pgina 9
T17.1
CORRIENTE Id
POTENCIA DEMAND
FASE B FASE B
720
4.21667
506
0.2025
720
506
24.3
4.21667 0.2025
Pgina 10
24.3
T18.1
Sotano
Circuito
Pos.
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
MODELO:
MARCA:
MONTAJE:
Pgina 1
T18.1
Descripcin
VOLTAJE
Carga (VA)
120
120
84
120
0
71.00
TABLERO T19.1
208
180.00
1200.00
NQ442B225
VOLTAJE:
120/208
SQUARE D
BARRAS:
225 A
SUPERFICIAL
HILOS:
Pgina 2
T18.1
DISYUNTOR
CABLE (AWG)
Polos
AMP
Modelo
Fases
Neutro
20
QOB
12
12
20
QOB
12
12
20
QOB
12
12
100
QOB
1/0
1/0
MATERIAL
POLOS:
42
ALUMINIO
B/T:
SI
POLOS
MOD.
3F
B/N:
100%
QOB34125MC
DISYUNTOR PRINCIPAL:
Pgina 3
T18.1
E (AWG)
CANALIZACION
FACTORES DE DISEO
Tierra
(MM)
Tipo
F.de D.
12
13
EMT
0.5
12
13
EMT
0.5
12
13
EMT
1.0
0.3
38
EMT
0.6
0.3
R PRINCIPAL:
ALIMENT PROCEDE:
POT. INSTALADA:
IT01
POT. DEMANDA:
AMP
225
UBICACIN:
LOCAL 1
Pgina 4
FACTOR DE DEMANDA:
T18.1
T18.1
ACTORES DE DISEO
CARGA (VA)
L1
1.00%
1200
1.00%
L2
FACTORES DE DISEO
L3
1.00%
84
1.00%
0
2471
1.00%
1192
1.00%
1281
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
POT. INSTALADA:
3671
1276
1281
PREV:
POT. DEMANDA:
1116
728
384
F.U.:
FACTOR DE DEMANDA:
0.30
0.57
0.30
TOTAL:
Pgina 5
T18.1
ACTORES DE DISEO
CANALIZACION
CABLE (AWG)
F.de D.
Tipo
(MM)
Tierra
0.3
EMT
13
12
EMT
38
0.3
0.6
0.3
3500
CORRIENTE FASE A:
0.9
CORRIENTE FASE B:
8755.2
CORRIENTE FASE C:
Pgina 6
T18.1
CABLE (AWG)
DISYUNTOR
Neutro
Fases
Modelo
AMP
Polos
12
12
QOB
40
1/0
1/0
QOB
100
9.30
ALIMEN
6.07
Fases
Neutro
Tierra
(MM)
3.20
1/0
1/0
38
Pgina 7
T18.1
VOLTAJE
Carga (VA)
Descripcin
120
1200
TOMAC. EXTERNOS
2400.00
0
1012.00
TABLERO T17.1
81.00
ALIMENTADOR
MATERIAL
RUTA
CANALIZACION TIPO:
AL. 8000
SUB
CORRUGADA
Pgina 8
T18.1
Pos.
Circuito
POTENCIA INST
POTENCIA DEMAND
1200
360
84
42
2471
750.8582
0 20.5917
1192
12
1281
14
16
18
20
10
FASE A
CORRIENTE In
384.3
22
24
26
28
30
32
34
36
38
40
42
3671
1276
33
CAIDA TENSION
3%
Pgina 9
0 680.075
LONG.
10
T18.1
CORRIENTE In
CORRIENTE Id
POTENCIA DEMAND
360
0.7
0.35
42
6.25715
750.858213
9.93333
5.66729
0 680.0752351
10.675
3.2025
1110.858213 722.0752351
Pgina 10
T18.1
ENCIA DEMAND
384.3
384.3
Pgina 11
T19.1
Sotano
Circuito
Pos.
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
MODELO:
MARCA:
MONTAJE:
Pgina 1
T19.1
Descripcin
LUMINARIAS GENERAL
VOLTAJE
Carga (VA)
120
71
0
0
0
0
0
0
0
0
0
NQ442B225
VOLTAJE:
120/208
SQUARE D
BARRAS:
225 A
SUPERFICIAL
HILOS:
Pgina 2
T19.1
DISYUNTOR
CABLE (AWG)
Polos
AMP
Modelo
Fases
Neutro
20
QOB
12
12
MATERIAL
POLOS:
42
ALUMINIO
B/T:
SI
POLOS
MOD.
3F
B/N:
100%
QOB34125MC
DISYUNTOR PRINCIPAL:
Pgina 3
T19.1
E (AWG)
CANALIZACION
FACTORES DE DISEO
Tierra
(MM)
Tipo
F.de D.
12
13
EMT
0.5
R PRINCIPAL:
ALIMENT PROCEDE:
POT. INSTALADA:
UPS
POT. DEMANDA:
AMP
125
UBICACIN:
LOCAL 1
Pgina 4
FACTOR DE DEMANDA:
T19.1
T19.1
ACTORES DE DISEO
CARGA (VA)
L1
1.00%
71
L2
FACTORES DE DISEO
L3
180
1.00%
1200
1.00%
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
POT. INSTALADA:
71
180
1200
PREV:
POT. DEMANDA:
36
180
360
F.U.:
FACTOR DE DEMANDA:
0.50
1.00
0.30
TOTAL:
Pgina 5
T19.1
ACTORES DE DISEO
CANALIZACION
CABLE (AWG)
F.de D.
Tipo
(MM)
Tierra
1.0
EMT
13
12
0.3
EMT
13
12
3500
CORRIENTE FASE A:
0.9
CORRIENTE FASE B:
3667.95
CORRIENTE FASE C:
Pgina 6
T19.1
CABLE (AWG)
DISYUNTOR
Neutro
Fases
Modelo
AMP
Polos
12
12
QOB
20
12
12
QOB
20
0.30
ALIMEN
1.50
Fases
Neutro
Tierra
(MM)
3.00
1/0
1/0
50
Pgina 7
T19.1
Descripcin
VOLTAJE
Carga (VA)
120
180
120
1200
TOMAC. EXTERNOS
ALIMENTADOR
MATERIAL
RUTA
CANALIZACION TIPO:
AL. 8000
SUB
CORRUGADA
Pgina 8
T19.1
Pos.
Circuito
POTENCIA INST
POTENCIA DEMAND
FASE A
CORRIENTE In
71
35.5
180
180
1200
360
LONG.
33
CAIDA TENSION
1%
71
180
Pgina 9
1200
35.5
0.59167
180
360
T19.1
CORRIENTE In
CORRIENTE Id
POTENCIA DEMAND
0.29583
35.5
1.5
1.5
180
10
10
0.29583
1.5
35.5
180
Pgina 10
T19.1
ENCIA DEMAND
360
360
Pgina 11
T17.1
Tablero
LADO IZQUIERDO
CIRC.
FASE
Pos.
descripcin
V-LL
V-LN
fases
factor de uso
120
120
0.30
120
120
0.50
LUMINARIAS GENERAL
120
120
0.30
120
120
1.00
120
120
1.00
11
120
120
1.00
13
120
120
1.00
15
120
120
1.00
17
120
120
1.00
19
208
120
1.00
21
120
1.00
23
120
1.00
25
120
1.00
27
120
1.00
29
120
1.00
31
120
1.00
33
120
1.00
35
120
1.00
37
120
1.00
39
120
1.00
41
120
1.00
V-LL
V-LN
fases
factor de uso
120
Tablero
T17.1
LADO DERECHO
CIRC.
FASE
Pos.
descripcin
TOMAC. EXTERNO
120
120
0.30
120
120
0.50
120
120
0.30
120
120
0.30
10
120
120
0.30
12
120
120
0.30
14
120
120
0.30
16
120
120
0.30
18
120
120
0.30
20
208
120
1.00
22
120
1.00
24
26
28
30
32
34
36
38
40
42
208
208
208
208
208
120
1.00
120
1.00
120
1.00
120
1.00
120
1.00
120
1.00
120
1.00
120
1.00
120
1.00
120
1.00
CARGA 1
L-MOD 1
POTENCIA
Carga Instalada
Carga demandada
Longitud
Corriente
fase a
fase b
fase c
fase a
fase b
fase c
mts
amp
35
0.00
112
56
28
0.47
81
24.3
28
0.20
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
17
CARGA 1
T-MOD 1
POTENCIA
Carga Instalada
Carga demandada
Longitud
Corriente
fase a
fase b
fase c
fase a
fase b
fase c
mts
amp
2400
720
30
6.00
900
450
20
3.75
10
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
180
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1012
81
720
506
24.3
CORRIENTE:
F.U.
6.00
0.3
4.22
0.5
0.20
0.3
CARGA 2
CARGA 3
L-MOD 5
L-MOD 2
15
28
CARGA 4
CARGA 5
CARGA 6
CARGA 7
CARGA 8
CARGA 9
CARGA 10
CARGA 11
CARGA 6
CARGA 7
CARGA 8
CARGA 9
CARGA 10
CARGA 11
4
2
CARGA 2
CARGA 3
CARGA 4
CARGA 5
T-MOD 2
600
CARGA 12
CARGA 13
CARGA 14
CARGA 15
CARGA 16
CARGA 17
CARGA 18
CARGA 19
CARGA 20
CARGA 21
CARGA 12
CARGA 13
CARGA 14
CARGA 15
CARGA 16
CARGA 17
CARGA 18
CARGA 19
CARGA 20
CARGA 21
SUB
CORRUGADA
33
CARGA 22
CARGA 23
CARGA 24
CARGA 25
CARGA 26
CARGA 27
CARGA 28
CARGA 22
CARGA 23
CARGA 24
CARGA 25
CARGA 26
CARGA 27
CARGA 28
T18.1
Tablero
LADO IZQUIERDO
CIRC.
1
FASE
Pos.
descripcin
LUMINARIAS GENERAL EXTERIOR
fases
factor de uso
120
0.50
120
0.50
120
1.00
208
120
0.50
208
120
1.00
11
208
120
0.30
13
120
1.00
15
120
1.00
17
120
1.00
19
120
1.00
21
120
1.00
23
120
1.00
25
120
1.00
27
120
1.00
29
120
1.00
31
120
1.00
33
120
1.00
35
120
1.00
37
120
1.00
39
120
1.00
41
120
1.00
Tablero
TABLERO T19.1
voltaje
T18.1
LADO DERECHO
CIRC.
FASE
Pos.
descripcin
V-LL
V-LN
fases
factor de uso
120
120
0.30
120
120
0.30
120
120
0.30
208
120
0.30
10
208
120
0.50
12
208
120
0.30
14
120
120
0.50
16
120
120
0.50
18
120
120
0.50
20
208
120
0.50
22
TOMAC. EXTERNOS
TABLERO T17.1
120
0.50
24
26
28
30
32
34
36
38
40
42
208
120
120
208
120
0.50
2
120
208
120
120
120
120
0.50
0.50
120
208
0.50
0.50
120
208
0.50
0.50
0.50
0.50
0.50
CARGA 1
L-MOD 2
POTENCIA
Carga Instalada
Carga demandada
Longitud
Corriente
fase a
fase b
fase c
fase a
fase b
fase c
mts
amp
15
0.00
84
42
0.35
0.00
71.00
35.5
0.17
180.00
180
0.87
1200.00
360
1.73
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
28
CARGA 1
T-MOD 2
POTENCIA
Carga Instalada
Carga demandada
Longitud
Corriente
mts
amp
fase a
fase b
fase c
fase a
fase b
fase c
1200
360
0.00
2400.00
720
6.00
1012.00
506
4.22
81.00
24.3
0.20
0.00
0.00
0.00
15
0.00
15
0.00
3.00
18
0.00
600
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
1276
1281
1115.5
728
384.3
CORRIENTE:
F.U.
9.30
0.3038681558
6.07
0.5705329154
3.20
0.3
CARGA 2
CARGA 3
CARGA 4
CARGA 5
CARGA 6
CARGA 7
CARGA 8
CARGA 9
CARGA 10
CARGA 11
CARGA 2
CARGA 3
CARGA 4
CARGA 5
CARGA 6
CARGA 7
CARGA 8
CARGA 9
CARGA 10
CARGA 11
CARGA 12
CARGA 13
CARGA 14
CARGA 15
CARGA 16
CARGA 17
CARGA 18
CARGA 19
CARGA 20
CARGA 21
CARGA 12
CARGA 13
CARGA 14
CARGA 15
CARGA 16
CARGA 17
CARGA 18
CARGA 19
CARGA 20
CARGA 21
SUB
CORRUGADA
33
CARGA 22
CARGA 23
CARGA 24
CARGA 25
CARGA 26
CARGA 27
CARGA 28
CARGA 22
CARGA 23
CARGA 24
CARGA 25
CARGA 26
CARGA 27
CARGA 28
T19.1
Tablero
LADO IZQUIERDO
CIRC.
FASE
Pos.
V-LL
V-LN
fases
factor de uso
120
120
0.50
120
120
1.00
120
120
0.30
120
120
0.50
120
120
0.50
11
120
120
0.50
13
120
120
0.50
15
120
120
0.50
17
120
120
0.50
19
120
120
0.50
21
120
120
1.00
23
120
120
1.00
25
120
120
1.00
27
120
120
1.00
29
120
120
1.00
31
120
120
1.00
33
120
120
1.00
35
120
120
1.00
37
120
120
1.00
39
120
120
1.00
41
120
120
1.00
V-LL
V-LN
fases
factor de uso
120
120
0.50
Tablero
descripcin
LUMINARIAS GENERAL
T19.1
LADO DERECHO
CIRC.
FASE
Pos.
descripcin
120
120
1.00
TOMAC. EXTERNOS
120
120
0.30
120
120
0.50
10
120
120
0.50
12
120
120
0.50
14
120
120
0.50
16
120
120
0.50
18
120
120
0.50
20
208
120
0.50
22
120
1.00
24
26
28
30
32
34
36
38
40
42
208
120
120
208
120
1.00
2
120
208
120
120
120
120
1.00
1.00
120
208
1.00
1.00
120
208
1.00
1.00
1.00
1.00
1.00
CARGA 1
L-MOD 5
POTENCIA
Carga Instalada
Carga demandada
Longitud
Corriente
fase a
fase b
fase c
fase a
fase b
fase c
mts
amp
71
35.5
0.30
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
15
CARGA 1
T-MOD 1
POTENCIA
Carga Instalada
Carga demandada
Longitud
Corriente
mts
amp
fase a
fase b
fase c
fase a
fase b
fase c
0.00
180
180
1.50
1200
360
0.00
0.00
0.00
0.00
0.00
0.00
15
0.00
15
0.00
3.00
180
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
15
0.00
71
1200
35.5
180
360
Corriente:
0.30
1.50
3.00
F.U.
0.5
0.3
180
CARGA 2
CARGA 3
CARGA 4
CARGA 5
CARGA 6
CARGA 7
CARGA 8
CARGA 9
CARGA 10
CARGA 11
CARGA 3
CARGA 4
CARGA 5
CARGA 6
CARGA 7
CARGA 8
CARGA 9
CARGA 10
CARGA 11
L-MOD 2
28
CARGA 2
T-MOD 2
600
CARGA 12
CARGA 13
CARGA 14
CARGA 15
CARGA 16
CARGA 17
CARGA 18
CARGA 19
CARGA 20
CARGA 21
CARGA 12
CARGA 13
CARGA 14
CARGA 15
CARGA 16
CARGA 17
CARGA 18
CARGA 19
CARGA 20
CARGA 21
SUB
CORRUGADA
33
CARGA 22
CARGA 23
CARGA 24
CARGA 25
CARGA 26
CARGA 27
CARGA 28
CARGA 22
CARGA 23
CARGA 24
CARGA 25
CARGA 26
CARGA 27
CARGA 28
LUM.
L-MOD 1
TIPO
FLUORESCENTE
TIPO
DIM
# LAMP
TIPO LAMP.
POT X LAMP (W)
VOLTAJE
60X5
1
T-8
17
120
DIM
# LAMP
TIPO LAMP.
POT X LAMP (W)
VOLTAJE
POT. LUMINARIA
(W)
MODELO
MARCA
17
POT. LUMINARIA
(W)
MODELO
MARCA
T-MOD 1
TIPO
AMP
VOLTAJE
FASES
TOM.
T-MOD 2
DOBLE
15
120
1
TIPO
AMP
VOLTAJE
FASES
TAPA
METALICA
TAPA
HILOS
HILOS
180
ESPECIFICAC.
GENERAL
MARFIL
NEMA
NEMA
MODELO
MARCA
MODELO
MARCA
L-MOD 2
L-MOD 3
FLUORESCENTE
TIPO
FLUOR-EMERG
TIPO
25X42
1
T-8
28
120
DIM
# LAMP
TIPO LAMP.
POT X LAMP (W)
VOLTAJE
60X60
3
T-8
17
120
DIM
# LAMP
TIPO LAMP.
POT X LAMP (W)
VOLTAJE
28
POT. LUMINARIA
(W)
MODELO
MARCA
51
POT. LUMINARIA
(W)
MODELO
MARCA
Luxmark Wal-Pak
Cooper Lighting
T-MOD 2
T-MOD 3
GFCI
15
120
1
TIPO
AMP
VOLTAJE
FASES
T-MOD 4
EXTRACTOR
15
120
1
TIPO
AMP
VOLTAJE
FASES
METALICA
TAPA
N/A
TAPA
HILOS
HILOS
600
ESPECIFICAC.
GENERAL
MARFIL
250
ESPECIFICAC.
GENERAL
N/A
NEMA
NEMA
MODELO
MARCA
MODELO
MARCA
L-MOD 4
L-MOD 5
L-MOD 6
FLUOR-EMERG
TIPO
FLUOR. COMPACTO
TIPO
FLUORESCENTE
60X120
3
T-8
32
120
DIM
# LAMP
TIPO LAMP.
POT X LAMP (W)
VOLTAJE
25CM
1
T-8
15
120
DIM
# LAMP
TIPO LAMP.
POT X LAMP (W)
VOLTAJE
60X60
3
T-8
17
120
96
POT. LUMINARIA
(W)
MODELO
MARCA
15
POT. LUMINARIA
(W)
MODELO
MARCA
51
T-MOD 4
T-MOD 5
ROTULO
20
120
1
TIPO
AMP
VOLTAJE
FASES
T-MOD 6
AIRE ACOND
33
208
1
TIPO
AMP
VOLTAJE
FASES
C0CINA
20
120
1
METALICA
TAPA
METALICA
TAPA
METALICA
HILOS
HILOS
1000
ESPECIFICAC.
GENERAL
MARFIL
4000
ESPECIFICAC.
GENERAL
MARFIL
NEMA
NEMA
MODELO
MARCA
MODELO
MARCA
1500
ESPECIFICAC.
GENERAL
MARFIL
L-MOD 7
TIPO
FLUORESCENTE
DIM
# LAMP
TIPO LAMP.
POT X LAMP (
VOLTAJE
60X60
3
T-8
17
120
POT.
LUMINARIA
(W)
MODELO
MARCA
51
T-MOD 7
T-MOD 8
TIPO
AMP
VOLTAJE
FASES
COMPUTO
15
120
1
TIPO
AMP
VOLTAJE
FASES
COMPUTO
15
120
3
TAPA
METALICA
TAPA
METALICA
HILOS
POT
ASIGNADA
(VA)
GRADO
USO
COLOR
3
300
ESPECIFICAC.
GENERAL
ROJO
HILOS
POT
ASIGNADA/F
ASE (VA)
GRADO
USO
COLOR
NEMA
NEMA
MODELO
MARCA
MODELO
MARCA
3
5000
N/A
COMPUTO
N/A
SUB
CORRUGADA
33
Resumen
TABLA DE R
TRANSFORMADOR
KVA TOTALES
KVA DEMANDADOS
FACTOR DE DEMANDA
FACTOR DE POTENCIA
FASES
LINEAS VIVAS
NEUTRO
TIERRA
LONGITUD (MTS)
VOLTAJE NOMINAL
% CAIDA DE VOLTAJE
TABLERO T2.1
#REF!
#REF!
#REF!
0.9
TABLERO T3.1
#REF!
#REF!
#REF!
0.8
3
3
1
1
3
3
1
1
3
3
1
1
120/208
120/208
120/208
Pgina 49
Resumen
120/208
Pgina 50
#REF!
TABLERO T19.1
1.451
0.5755
0.40
0.9
3
3
1
1
120/208
Resumen
A UTILIZAR
400
SUB
Pgina 51
Resumen
CORRUGADA
33
Pgina 52