WET ROTOR CIRCULATORS

Energ iy

a
e

HOT WATER SYSTEMS


Operating range: from 0.5 to 3,6 m3/h with head up
to 6 metres.
Liquid temperature range:
from -10C to +85C (for sanitary use)
+110C (for others use).
Pumped liquid characteristics: clean, free from solids
and mineral oils, non viscous, chemically neutral, close to
the characteristics of water (max 30% glycol).
Maximum working pressure: 10 bar (1000 kPa ).
Protection level: IP 44.
Insulation class: F.
Cable grommet: PG 11.
Installation: with motor axis horizontal.

Pump for hot water circulation in hot water domestic


systems of the closed and pressurised or open tank type.
Also suitable for solar power systems.
Single body formed of the bronze hydraulic unit. Diecast aluminium motor casing. Technopolymer impeller.
Ceramic driving shaft mounted on graphite brushings
lubricated by the pumped liquid itself.
Stainless steel protective rotor sleeve, stator sleeve and
closing flange.
Ceramic thrust bearing, E.P.D.M. O rings.
The two-pole or four-pole asynchronous motor with wet
rotor is self-protected for resistance.
No overload protection required.
* see performance curves

TECHNICAL DATA
MODEL

CODE

ELECTRICAL DATA

UNIONS ON REQUEST

CENTRE
DISTANCE
mm

VOLTAGE
50 Hz

n
r.p.m.
1/min

P1 MAX
W

In
A

Vc

CAPACITOR

STANDARDIZED

MINIMUM
HEAD
PRESSURE

SPECIAL

VS 8/150

60112968

150

1 x 230 V ~

1340

22

0,14

1,5

450

BRASS 1/2 F - 3/4 F - 1 F


COPPER d22 e d28

t +90C
m.c.a. 1,5

VS 16/150

60115297

150

1 x 230 V ~

2784

41

0,19

1,5

450

BRASS 1/2 F - 3/4 F - 1 F


COPPER d22 e d28

t +90C
m.c.a. 1,5

VS 35/150

60115298

150

1 x 230 V ~

2470

55

0,24

1,7

450

BRASS 1/2 F - 3/4 F - 1 F


COPPER d22 e d28

t +90C
m.c.a. 1,5

VS 65/150

60115299

150

1 x 230 V ~

2317

77

0,34

450

BRASS 1/2 F - 3/4 F - 1 F


COPPER d22 e d28

t +90C
m.c.a. 1,5

10
8

12
10

14
12

16

14

18

a
e

20

10

16

VS 8/150
B

B1

VS 16/150

12

VS 35/150
8

L2

30

B
B2

20

a
e

H
ft

VS 65/150

Energ iy

Energ iy

40

Q US gpm

16 Q IMP gpm

H1

50

H2

L1

60

0
0

P H
kPa m

0
0

0,2

10

MODEL

VSA 35/130
VSA 35/130 1/2
VSA 35/180
VSA 35/180 X

1
20

0,4

2
30

0,6

40

3
0,8

50

60

1,2

70

Q m3/h
Q l/s
Q l/min

L1

L2

B1

B2

H1

H2

F
GAS

WEIGHT
KG

Q.TY
x
PALLET

150
150
150
150

98
98
98
98

60
60
60
60

104
104
104
104

78
78
78
78

26
26
26
26

124
124
124
124

75
75
75
75

49
49
49
49

11/2
11/2
11/2
11/2

134
134
134
134

188
188
188
188

150
150
150
150

2,6
2,6
2,6
2,6

180
180
180
180

DAB PUMPS reserves the right to make modifications without notice

PACKAGING DIMENSIONS