Anda di halaman 1dari 1

ISO5167 flow calculations, Arian flow cad demo

Fluid

Primary device

Conditions

_____________________
Type

Pure

Name

Methane

State

Gas

_____________________
Type

Iso 5167-2:2003 Orifice plate

Case

Corner Taps

Bore [d]

240.73(mm) @ 20(C) / Carbon Steel (SAE1020)

Pipe inner diameter [D]

488.96(mm) @ 20(C) / Carbon Steel (SAE1020)

_____________________
Diferential presure [dp]

0.687891827(Bar) = 68789.18269999999(Pa)

Presure upstream [p]

7.88(Bar Absolute) = 788000(Pa Absolute)

Temperature [t]

10.7984(C) = 283.9484(Kelvin)

Properties at (t, p) _____________________

Flow

Density (Kg/m3)

5.4428544

Viscosity (Pa*sec)

1.0709832E-05

Isentropic exponent

1.3120089

_____________________
Qm (Kg/Sec)

23.856022

Qv (Cubic Meter/Sec)

4.382998

U (Meter/Sec)

23.345692

Presure loss (Bar)

0.50783914

Presure loss (Pa)

50783.914

Reynolds

5800804

C discharge coeff.

0.60270423

e expasion factor

0.9751668

Uncertainty on C+e (%)

0.55157173

Notes:
Fluid physical properties density, viscosity and isentropic exponent are obtained from tables based on "NIST Standard
Reference Database 23" as function of actual temperature and absolute presure. Steam properties are obtained from
IAPWS-IF97 formulas.
Bore and pipe diameters at working temperature are obtained from thermal expansion coefficient for the materials they
are made.
Flow is calculated recursively from Iso 5167 formulas using a demo version of Arian flow CAD V2.0 software, integral
part of the Fl40 mass flow computer device.