Anda di halaman 1dari 243

Tu=

4.57 KN-MET Tc=


1.2 KN-MET Ts=
6.1 KN-MET LOAD
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

17

1.99 SQ.CM.

___5519J____________________
430X 200X 300_____________________5692J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 10994 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
13.09 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
23.32 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
257.MM2, RHO=0.0050, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

11687.7 cm^4

B E A M

N O. 10994 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


39.60 KNS Vc=
41.59 KNS Vs=
11.21 KNS
Tu=
4.75 KN-MET Tc=
1.2 KN-MET Ts=
6.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.07 SQ.CM.
AT END
SUPPORT - Vu=
38.90 KNS Vc=
51.15 KNS Vs=
0.72 KNS
Tu=
4.75 KN-MET Tc=
1.2 KN-MET Ts=
6.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.07 SQ.CM.

___5523J____________________
430X 200X 300_____________________5760J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11002 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
10.11 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
144.MM2, RHO=0.0028, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|

2
256.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
20.34 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
223.MM2, RHO=0.0043, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11002 D E S I G N

8946.9 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


34.98 KNS Vc=
41.53 KNS Vs=
5.11 KNS
Tu=
4.58 KN-MET Tc=
1.2 KN-MET Ts=
6.1 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.99 SQ.CM.
AT END
SUPPORT - Vu=
34.28 KNS Vc=
50.23 KNS Vs=
0.00 KNS
Tu=
4.58 KN-MET Tc=
1.2 KN-MET Ts=
6.1 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.99 SQ.CM.

___5527J____________________
430X 200X 300_____________________5824J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM

NO. 11010 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

LEN -

430. MM

LEVEL

HEIGHT

FY -

412.

BAR INFO

FC -

25.
FROM

MPA, SIZE TO

200. X

300. MMS
ANCHOR

(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.09 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
86.MM2, RHO=0.0017, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
15.44 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11010 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


15.95 KNS Vc=
41.19 KNS Vs=
0.00 KNS
Tu=
4.40 KN-MET Tc=
1.1 KN-MET Ts=
5.9 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.92 SQ.CM.
AT END
SUPPORT - Vu=
15.02 KNS Vc=
61.96 KNS Vs=
0.00 KNS
Tu=
4.40 KN-MET Tc=
1.1 KN-MET Ts=
5.9 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.92 SQ.CM.

___5531J____________________
430X 200X 300_____________________5885J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11018 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.98 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
99.MM2, RHO=0.0019, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
15.24 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11018 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


6.13 KNS Vc=
40.68 KNS Vs=
0.00 KNS
Tu=
3.68 KN-MET Tc=
1.1 KN-MET Ts=
4.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.60 SQ.CM.
AT END
SUPPORT - Vu=
5.43 KNS Vc=
40.68 KNS Vs=
0.00 KNS
Tu=
3.68 KN-MET Tc=
1.1 KN-MET Ts=
4.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.60 SQ.CM.

___5535J____________________
430X 200X 300_____________________5948J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11034 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

1470. MM

FY -

412.

FC -

25.

MPA, SIZE -

250. X

400. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
1470.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
33.39 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
299.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24860.4 cm^4

2
357.
4 - 10MM
0.
1248.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
39.62 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
311.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24710.7 cm^4

3
357.
2 - 10MM
773.
1470.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
10.71 KN-MET AT 1470.MM, LOAD
16|
|
REQD STEEL=
108.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 165. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|

Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11034 D E S I G N

13627.4 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


29.04 KNS Vc=
65.89 KNS Vs=
0.00 KNS
Tu=
0.56 KN-MET Tc=
2.1 KN-MET Ts=
0.0 KN-MET LOAD
16
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 179. MM C/C FOR 385. MM
AT END
SUPPORT - Vu=
30.95 KNS Vc=
65.89 KNS Vs=
0.00 KNS
Tu=
0.56 KN-MET Tc=
2.1 KN-MET Ts=
0.0 KN-MET LOAD
16
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 179. MM C/C FOR 385. MM

___5543J____________________ 1470X 250X 400_____________________5607J____


|
|
||=========================================================================||
| 4No10 H 357.
0.TO 1248
|
2No10 H 357. 773.TO 1470|
| |
| 4*12c/c179
|
|
|
|
4*12c/c179 | |
| 4No10 H 43.
0.TO 1470
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
|
oo
|
| 4#10
| | 4#10
| | 4#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11035 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

3470. MM

FY -

412.

FC -

25.

MPA, SIZE -

250. X

400. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
3470.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
32.62 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
299.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|

|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24860.4 cm^4

2
357.
4 - 10MM
0.
1837.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
28.90 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
297.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24860.4 cm^4

3
357.
4 - 10MM
1489.
3470.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
37.84 KN-MET AT 3470.MM, LOAD
14|
|
REQD STEEL=
299.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11035 D E S I G N

24860.4 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.22 KNS Vc=
72.49 KNS Vs=
Tu=
0.60 KN-MET Tc=
2.3 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
7.92 KNS Vc=
72.49 KNS Vs=
Tu=
0.60 KN-MET Tc=
2.3 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5543J____________________ 3469X 250X 400_____________________5545J____


|
|
||=========================================================================||
| 4No10 H 357.
0.TO 1837
4No10 H 357.1489.TO 3470
|
|
|
| 4No10 H 43.
0.TO 3470
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11036 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

3470. MM

FY -

412.

FC -

25.

MPA, SIZE -

250. X

400. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
3470.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
20.43 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
209.MM2, RHO=0.0023, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 163. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

18652.9 cm^4

2
357.
4 - 10MM
0.
1547.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
27.35 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
281.MM2, RHO=0.0031, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24860.4 cm^4

3
357.
4 - 10MM
1778.
3470.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
35.43 KN-MET AT 3470.MM, LOAD
14|
|
REQD STEEL=
299.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11036 D E S I G N

24860.4 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


12.33 KNS Vc=
70.66 KNS Vs=
0.00 KNS
Tu=
0.20 KN-MET Tc=
2.3 KN-MET Ts=
0.0 KN-MET LOAD
13
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
27.80 KNS Vc=
71.25 KNS Vs=
0.00 KNS
Tu=
0.37 KN-MET Tc=
2.4 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 178. MM C/C FOR 1385. MM

___5544J____________________

3469X 250X

400_____________________5546J____

||================================
=====================================||
| 4No10 H 357.
0.TO 1547
4No10 H|357.1778.TO|3470
|
|
| |
|
|
|
|
|
|
9*12c/c179 | |
| 2No12 H 44.
0.TO 3470
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11037 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2740. MM

FY -

412.

FC -

25.

MPA, SIZE -

250. X

400. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
2740.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
36.18 KN-MET AT 2740.MM, LOAD
17|
|
REQD STEEL=
299.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24860.4 cm^4

2
357.
4 - 10MM
0.
1532.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
38.19 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
299.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24860.4 cm^4

3
357.
4 - 10MM
1093.
2740.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
34.37 KN-MET AT 2740.MM, LOAD
16|
|
REQD STEEL=
299.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24860.4 cm^4

B E A M

N O. 11037 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


30.87 KNS Vc=
72.05 KNS Vs=
0.00 KNS
Tu=
0.62 KN-MET Tc=
2.4 KN-MET Ts=
0.0 KN-MET LOAD
17
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 179. MM C/C FOR 1020. MM
AT END
SUPPORT - Vu=
2.40 KNS Vc=
73.33 KNS Vs=
Tu=
0.30 KN-MET Tc=
2.4 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13

___5545J____________________ 2740X 250X 400_____________________5546J____


|
|
||=========================================================================||
| 4No10|H 357.
0.TO 1532 |
4No10 H 357.1093.TO 2740
|
| 7*12c/c179
|
|
|
|
|
| 4No10|H 43.
0.TO 2740 |
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11042 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

680. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
680.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.05 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
85.MM2, RHO=0.0017, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
680.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
9.42 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
134.MM2, RHO=0.0026, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11042 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


5.76 KNS Vc=
41.31 KNS Vs=
0.00 KNS
Tu=
1.64 KN-MET Tc=
1.1 KN-MET Ts=
2.2 KN-MET LOAD
15
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 359. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.72 SQ.CM.
AT END
SUPPORT - Vu=
4.69 KNS Vc=
41.69 KNS Vs=
0.00 KNS
Tu=
1.64 KN-MET Tc=
1.1 KN-MET Ts=
2.2 KN-MET LOAD
15
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 359. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.72 SQ.CM.

___5547J____________________
680X 200X 300_____________________5613J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 680
|
|
|
|
|
| 5*12c/c 94|
|
|
|
|
5*12c/c 94
|
| 2No10 H 43.
0.TO 680
|
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM

NO. 11043 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

LEN -

580. MM

LEVEL

HEIGHT

FY -

412.

BAR INFO

FC -

25.
FROM

MPA, SIZE TO

200. X

300. MMS
ANCHOR

(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
3.42 KN-MET AT
580.MM, LOAD
14|
|
REQD STEEL=
48.MM2, RHO=0.0009, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
10.10 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
144.MM2, RHO=0.0028, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11043 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


6.76 KNS Vc=
40.72 KNS Vs=
0.00 KNS
Tu=
2.37 KN-MET Tc=
1.1 KN-MET Ts=
3.2 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 309. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.03 SQ.CM.
AT END
SUPPORT - Vu=
5.84 KNS Vc=
74.98 KNS Vs=
0.00 KNS
Tu=
2.37 KN-MET Tc=
1.1 KN-MET Ts=
3.2 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 309. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.03 SQ.CM.

___5547J____________________
579X 200X 300_____________________5608J____
|
|
||=========================================================================||
| 2No10 H 257. | 0.TO 580 |
|
|
|
|
| 5*12c/c 94 |
|
|
|
5*12c/c 94
|
| 2No10 H 43. | 0.TO 580 |
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11045 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

680. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
680.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.25 KN-MET AT
510.MM, LOAD
16|
|
REQD STEEL=
60.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
680.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
7.12 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
101.MM2, RHO=0.0020, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11045 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


5.35 KNS Vc=
41.11 KNS Vs=
0.00 KNS
Tu=
1.65 KN-MET Tc=
1.1 KN-MET Ts=
2.2 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 359. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.72 SQ.CM.
AT END
SUPPORT - Vu=
4.28 KNS Vc=
41.19 KNS Vs=
0.00 KNS
Tu=
1.65 KN-MET Tc=
1.1 KN-MET Ts=
2.2 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 359. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.72 SQ.CM.

___5549J____________________
680X 200X 300_____________________5614J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 680
|
|
|
|
|
| 5*12c/c 94|
|
|
|
|
5*12c/c 94
|
| 2No10 H 43.
0.TO 680
|
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11051 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

3470. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
3470.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
5.05 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
71.MM2, RHO=0.0014, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
1457.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
9.90 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
141.MM2, RHO=0.0027, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

3
257.
2 - 10MM
1868.
3470.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
10.50 KN-MET AT 3470.MM, LOAD
14|
|
REQD STEEL=
150.MM2, RHO=0.0029, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|

Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11051 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


4.33 KNS Vc=
41.50 KNS Vs=
0.00 KNS
Tu=
1.45 KN-MET Tc=
1.1 KN-MET Ts=
1.9 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1754. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.63 SQ.CM.
AT END
SUPPORT - Vu=
5.46 KNS Vc=
41.50 KNS Vs=
0.00 KNS
Tu=
1.45 KN-MET Tc=
1.1 KN-MET Ts=
1.9 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1754. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.63 SQ.CM.

___5551J____________________ 3469X 200X 300_____________________5553J____


|
|
||==============================
===================================||
| 2No10 H 257.| 0.TO 1457| |
2No10 H 257.1868.TO 3470| | | | |
| 20*12c/c 94 | | | | | |
| | | | | | | 20*12c/c 94 | |
| 2No10 H 43.| 0.TO 3470| |
| | | | | | | | | | | | |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11052 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

3470. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
3470.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.38 KN-MET AT
0.MM, LOAD
14|

|
REQD STEEL=
104.MM2, RHO=0.0020, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
1457.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
10.39 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
148.MM2, RHO=0.0029, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

3
256.
2 - 12MM
1519.
3470.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
13.30 KN-MET AT 3470.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11052 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


3.98 KNS Vc=
40.82 KNS Vs=
0.00 KNS
Tu=
1.48 KN-MET Tc=
1.1 KN-MET Ts=
2.0 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1754. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.64 SQ.CM.
AT END
SUPPORT - Vu=
5.82 KNS Vc=
40.82 KNS Vs=
0.00 KNS
Tu=
1.48 KN-MET Tc=
1.1 KN-MET Ts=
2.0 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1754. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.64 SQ.CM.

___5552J____________________ 3469X 200X 300_____________________5554J____


|
|
||============================== ==========================================||
| 2No10 H 257.| 0.TO 1457| |
2No12 H|256.1519.TO|3470 | | | | | | |
| 20*12c/c 94 | | | | | |
| | | | | | | | | 20*12c/c 94 | |
| 2No10 H 43.| 0.TO 3470| |
| | | | | | | | | | | | | | |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|

|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
oo
|
| 2#12
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
oo
|
| 2#12
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
oo
|
| 2#12
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11053 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2740. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2740.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
12.65 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
1502.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
15.23 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

3
256.
2 - 12MM
1124.
2740.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
16.29 KN-MET AT 2740.MM, LOAD
16|
|
REQD STEEL=
177.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11053 D E S I G N

AT START SUPPORT - Vu=


Tu=
0.15 KN-MET Tc=

8871.6 cm^4

R E S U L T S - SHEAR

4.45 KNS Vc=


41.17 KNS Vs=
1.1 KN-MET Ts=
0.0 KN-MET

0.00 KNS
LOAD
13

STIRRUPS ARE NOT REQUIRED.


AT END
SUPPORT - Vu=
5.89 KNS Vc=
41.17 KNS Vs=
Tu=
0.15 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13

___5553J____________________ 2740X 200X 300_____________________5554J____


|
|
||=========================================================================||
| 2No12 H 256.
0.TO 1502
2No12 H 256.1124.TO 2740
|
|
|
| 2No12 H 44.
0.TO 2740
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11060 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
25.17 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
279.MM2, RHO=0.0054, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

11687.7 cm^4

2
254.
2 - 16MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
34.31 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
390.MM2, RHO=0.0076, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|
|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

14071.6 cm^4

B E A M

N O. 11060 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


13.56 KNS Vc=
41.85 KNS Vs=
0.00 KNS
Tu=
7.08 KN-MET Tc=
1.1 KN-MET Ts=
9.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
3.08 SQ.CM.
AT END
SUPPORT - Vu=
11.76 KNS Vc=
41.85 KNS Vs=
0.00 KNS
Tu=
7.08 KN-MET Tc=
1.1 KN-MET Ts=
9.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
3.08 SQ.CM.

___5555J____________________
430X 200X 300_____________________5691J____
|
|
||=========================================================================||
| 2No16 H 254.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 4No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#16
| | 2#16
| | 2#16
| | 2#16
| | 2#16
|
| 2#16
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11063 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

200. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.00 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
99.MM2, RHO=0.0019, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|

Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
0.81 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
11.MM2, RHO=0.0002, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11063 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


22.67 KNS Vc=
89.33 KNS Vs=
0.00 KNS
Tu=
1.76 KN-MET Tc=
1.5 KN-MET Ts=
2.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.77 SQ.CM.
AT END
SUPPORT - Vu=
21.75 KNS Vc=
89.33 KNS Vs=
0.00 KNS
Tu=
1.76 KN-MET Tc=
1.5 KN-MET Ts=
2.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.77 SQ.CM.

___5561J____________________
200X 200X 300_____________________5562J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 200
|
| |
| 3*12c/c 94
|
3*12c/c 94 | |
| 2No10 H 43.
0.TO 200
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11064 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
12.65 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
6.85 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
97.MM2, RHO=0.0019, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11064 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


22.01 KNS Vc=
86.48 KNS Vs=
0.00 KNS
Tu=
1.53 KN-MET Tc=
1.5 KN-MET Ts=
2.0 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.67 SQ.CM.
AT END
SUPPORT - Vu=
20.24 KNS Vc=
43.90 KNS Vs=
0.00 KNS
Tu=
1.53 KN-MET Tc=
1.5 KN-MET Ts=
2.0 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.67 SQ.CM.

___5562J____________________
419X 200X 300_____________________5655J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11065 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

200. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.36 KN-MET AT
133.MM, LOAD
14|
|
REQD STEEL=
104.MM2, RHO=0.0020, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
0.02 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
0.MM2, RHO=0.0000, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11065 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


18.90 KNS Vc=
23.76 KNS Vs=
1.44 KNS
Tu=
1.87 KN-MET Tc=
0.3 KN-MET Ts=
2.5 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.81 SQ.CM.
AT END
SUPPORT - Vu=
19.82 KNS Vc=
23.76 KNS Vs=
2.66 KNS
Tu=
1.87 KN-MET Tc=
0.3 KN-MET Ts=
2.5 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.81 SQ.CM.

___5563J____________________
200X 200X 300_____________________5564J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 200
|
| |
| 3*12c/c 94
|
3*12c/c 94 | |
| 2No10 H 43.
0.TO 200
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11066 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
13.31 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
7.38 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
104.MM2, RHO=0.0020, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11066 D E S I G N

AT START SUPPORT - Vu=

17.85 KNS

Vc=

6585.1 cm^4

R E S U L T S - SHEAR

87.39 KNS

Vs=

0.00 KNS

Tu=
2.41 KN-MET Tc=
1.5 KN-MET Ts=
3.2 KN-MET LOAD
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

17

1.05 SQ.CM.

AT END
SUPPORT - Vu=
16.09 KNS Vc=
43.23 KNS Vs=
0.00 KNS
Tu=
2.41 KN-MET Tc=
1.5 KN-MET Ts=
3.2 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.05 SQ.CM.

___5564J____________________
419X 200X 300_____________________5783J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11067 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

200. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.52 KN-MET AT
200.MM, LOAD
17|
|
REQD STEEL=
92.MM2, RHO=0.0018, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

B E A M

N O. 11067 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


13.02 KNS Vc=
34.10 KNS Vs=
0.00 KNS
Tu=
1.47 KN-MET Tc=
0.9 KN-MET Ts=
2.0 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.64 SQ.CM.
AT END
SUPPORT - Vu=
13.94 KNS Vc=
34.10 KNS Vs=
0.00 KNS
Tu=
1.47 KN-MET Tc=
0.9 KN-MET Ts=
2.0 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.64 SQ.CM.

___5565J____________________
200X 200X 300_____________________5566J____
|
|
|
|
|
|
| 3*12c/c 94
3*12c/c 94
|
| 2No10 H 43.
0.TO 200
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11069 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

200. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
17.57 KN-MET AT
200.MM, LOAD
15|
|
REQD STEEL=
192.MM2, RHO=0.0037, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
4.15 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
58.MM2, RHO=0.0011, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11069 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


33.46 KNS Vc=
26.25 KNS Vs=
18.37 KNS
Tu=
2.33 KN-MET Tc=
0.5 KN-MET Ts=
3.1 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.02 SQ.CM.
AT END
SUPPORT - Vu=
33.82 KNS Vc=
26.25 KNS Vs=
18.84 KNS
Tu=
2.33 KN-MET Tc=
0.5 KN-MET Ts=
3.1 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.02 SQ.CM.

___5567J____________________
200X 200X 300_____________________5568J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 200
|
| |
| 3*12c/c 94
|
3*12c/c 94 | |
| 2No12 H 44.
0.TO 200
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM

NO. 11071 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

LEN -

200. MM

LEVEL

HEIGHT
(MM)

FY -

412.

BAR INFO

FC -

25.
FROM
(MM)

MPA, SIZE TO
(MM)

200. X

300. MMS
ANCHOR
STA END

_____________________________________________________________________

1
44.
2 - 12MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
16.67 KN-MET AT
183.MM, LOAD
15|
|
REQD STEEL=
182.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
1.49 KN-MET AT
200.MM, LOAD
14|
|
REQD STEEL=
21.MM2, RHO=0.0004, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11071 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


29.18 KNS Vc=
28.15 KNS Vs=
10.76 KNS
Tu=
2.25 KN-MET Tc=
0.6 KN-MET Ts=
3.0 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.98 SQ.CM.
AT END
SUPPORT - Vu=
29.54 KNS Vc=
28.15 KNS Vs=
11.24 KNS
Tu=
2.25 KN-MET Tc=
0.6 KN-MET Ts=
3.0 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.98 SQ.CM.

___5569J____________________
200X 200X 300_____________________5570J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 200
|
| |
| 3*12c/c 94
|
3*12c/c 94 | |
| 2No12 H 44.
0.TO 200
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|

|_________|

|_________|

|_________|

|_________|

|_________|

|_________|

=====================================================================
BEAM
LEN -

NO. 11072 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
15.57 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
0.92 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
13.MM2, RHO=0.0002, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11072 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.70 KNS Vc=
39.43 KNS Vs=
0.00 KNS
Tu=
1.80 KN-MET Tc=
1.0 KN-MET Ts=
2.4 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.78 SQ.CM.
AT END
SUPPORT - Vu=
2.38 KNS Vc=
39.43 KNS Vs=
0.00 KNS
Tu=
1.80 KN-MET Tc=
1.0 KN-MET Ts=
2.4 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.78 SQ.CM.

___5570J____________________
|

419X 200X

300_____________________5784J____
|

| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11073 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

200. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
15.20 KN-MET AT
200.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
0.19 KN-MET AT
200.MM, LOAD
14|
|
REQD STEEL=
3.MM2, RHO=0.0001, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11073 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


24.32 KNS Vc=
84.70 KNS Vs=
Tu=
2.31 KN-MET Tc=
1.4 KN-MET Ts=
3.1 KN-MET
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

0.00 KNS
LOAD
17

PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM


ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

1.01 SQ.CM.

AT END
SUPPORT - Vu=
23.97 KNS Vc=
44.74 KNS Vs=
0.00 KNS
Tu=
2.31 KN-MET Tc=
1.4 KN-MET Ts=
3.1 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.01 SQ.CM.

___5571J____________________
200X 200X 300_____________________5572J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 200
|
| |
| 3*12c/c 94
|
3*12c/c 94 | |
| 2No12 H 44.
0.TO 200
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11074 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
14.25 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11074 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


2.11 KNS Vc=
39.93 KNS Vs=
0.00 KNS
Tu=
1.62 KN-MET Tc=
1.0 KN-MET Ts=
2.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.70 SQ.CM.
AT END
SUPPORT - Vu=
2.79 KNS Vc=
39.93 KNS Vs=
0.00 KNS
Tu=
1.62 KN-MET Tc=
1.0 KN-MET Ts=
2.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.70 SQ.CM.

___5572J____________________
419X 200X 300_____________________5846J____
|
|
|
|
|
|
| 4*12c/c 94
4*12c/c 94
|
| 2No12 H 44.
0.TO 420
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11075 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

200. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
13.32 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

B E A M

N O. 11075 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


17.66 KNS Vc=
48.20 KNS Vs=
0.00 KNS
Tu=
1.71 KN-MET Tc=
1.4 KN-MET Ts=
2.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.75 SQ.CM.
AT END
SUPPORT - Vu=
17.31 KNS Vc=
42.41 KNS Vs=
0.00 KNS
Tu=
1.71 KN-MET Tc=
1.4 KN-MET Ts=
2.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.75 SQ.CM.

___5573J____________________
200X 200X 300_____________________5574J____
|
|
|
|
|
|
| 3*12c/c 94
3*12c/c 94
|
| 2No12 H 44.
0.TO 200
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11076 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
12.50 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|

Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11076 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


16.03 KNS Vc=
38.39 KNS Vs=
0.00 KNS
Tu=
0.14 KN-MET Tc=
1.0 KN-MET Ts=
0.0 KN-MET LOAD
15
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 229. MM
AT END
SUPPORT - Vu=
16.71 KNS Vc=
38.39 KNS Vs=
0.00 KNS
Tu=
0.14 KN-MET Tc=
1.0 KN-MET Ts=
0.0 KN-MET LOAD
15
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 229. MM

___5574J____________________
419X 200X 300_____________________5909J____
|
|
|
|
|
|
| 3*12c/c129
3*12c/c129
|
| 2No12 H 44.
0.TO 420
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11084 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

200. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.95 KN-MET AT
200.MM, LOAD
14|
|
REQD STEEL=
113.MM2, RHO=0.0022, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|

|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
0.46 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
6.MM2, RHO=0.0001, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11084 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


23.02 KNS Vc=
91.39 KNS Vs=
0.00 KNS
Tu=
1.95 KN-MET Tc=
1.6 KN-MET Ts=
2.6 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.85 SQ.CM.
AT END
SUPPORT - Vu=
22.10 KNS Vc=
91.39 KNS Vs=
0.00 KNS
Tu=
1.95 KN-MET Tc=
1.6 KN-MET Ts=
2.6 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.85 SQ.CM.

___5581J____________________
200X 200X 300_____________________5582J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 200
|
| |
| 3*12c/c 94
|
3*12c/c 94 | |
| 2No10 H 43.
0.TO 200
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM

NO. 11089 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

LEN -

200. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
200.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.59 KN-MET AT
117.MM, LOAD
14|
|
REQD STEEL=
93.MM2, RHO=0.0018, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11089 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


15.55 KNS Vc=
28.00 KNS Vs=
0.00 KNS
Tu=
1.64 KN-MET Tc=
0.6 KN-MET Ts=
2.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.71 SQ.CM.
AT END
SUPPORT - Vu=
16.47 KNS Vc=
28.00 KNS Vs=
0.00 KNS
Tu=
1.64 KN-MET Tc=
0.6 KN-MET Ts=
2.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 119. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.71 SQ.CM.

___5585J____________________
200X 200X 300_____________________5586J____
|
|
|
|
|
|
| 3*12c/c 94
3*12c/c 94
|
| 2No10 H 43.
0.TO 200
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11146 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

250. X

400. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
25.24 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
259.MM2, RHO=0.0029, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

24860.4 cm^4

2
357.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
11.38 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
115.MM2, RHO=0.0013, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 165. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11146 D E S I G N

13627.4 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.42 KNS Vc=
71.35 KNS Vs=
0.00 KNS
Tu=
2.59 KN-MET Tc=
2.3 KN-MET Ts=
3.4 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 132. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.82 SQ.CM.
AT END
SUPPORT - Vu=
0.28 KNS Vc=
71.35 KNS Vs=
0.00 KNS
Tu=
2.59 KN-MET Tc=
2.3 KN-MET Ts=
3.4 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 132. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.82 SQ.CM.

___5607J____________________
419X 250X 400_____________________5658J____
|
|
||=========================================================================||
| 2No10 H 357.
0.TO 420|
|
| |
| 3*12c/c132
|
|
3*12c/c132 | |
| 4No10 H 43.
0.TO 420|
|
| |

||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11148 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.28 KN-MET AT
580.MM, LOAD
14|
|
REQD STEEL=
60.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
3.73 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
52.MM2, RHO=0.0010, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11148 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


4.22 KNS Vc=
74.75 KNS Vs=
0.00 KNS
Tu=
1.58 KN-MET Tc=
1.1 KN-MET Ts=
2.1 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 309. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.69 SQ.CM.

AT END
SUPPORT - Vu=
3.30 KNS Vc=
40.71 KNS Vs=
0.00 KNS
Tu=
1.58 KN-MET Tc=
1.1 KN-MET Ts=
2.1 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 309. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.69 SQ.CM.

___5608J____________________
579X 200X 300_____________________5609J____
|
|
||=========================================================================||
| 2No10 H 257. | 0.TO 580 |
|
|
|
|
| 5*12c/c 94 |
|
|
|
5*12c/c 94
|
| 2No10 H 43. | 0.TO 580 |
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11149 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.45 KN-MET AT
580.MM, LOAD
13|
|
REQD STEEL=
63.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11149 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


2.46 KNS Vc=
40.56 KNS Vs=
Tu=
0.20 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13

AT END
SUPPORT - Vu=
1.24 KNS Vc=
40.40 KNS Vs=
Tu=
0.20 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13

___5609J____________________
580X 200X 300_____________________5610J____
|
|
|
|
|
|
|
|
| 2No10 H 43.
0.TO 580
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11150 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.43 KN-MET AT
0.MM, LOAD
13|
|
REQD STEEL=
62.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11150 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.52 KNS Vc=
40.42 KNS Vs=
Tu=
0.32 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
2.75 KNS Vc=
40.60 KNS Vs=
Tu=
0.32 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5610J____________________
580X 200X 300_____________________5611J____
|
|
|
|
|
|
|
|
| 2No10 H 43.
0.TO 580
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11151 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.15 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
58.MM2, RHO=0.0011, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
3.99 KN-MET AT
580.MM, LOAD
14|
|
REQD STEEL=
56.MM2, RHO=0.0011, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11151 D E S I G N

AT START SUPPORT - Vu=

5.32 KNS

Vc=

6585.1 cm^4

R E S U L T S - SHEAR

40.85 KNS

Vs=

0.00 KNS

Tu=

0.80 KN-MET

Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
6.54 KNS Vc=
65.46 KNS Vs=
Tu=
0.80 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

LOAD

13

0.00 KNS
LOAD
13

___5611J____________________
579X 200X 300_____________________5612J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 580
|
|
|
| 2No10 H 43.
0.TO 580
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11152 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

570. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
570.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
3.18 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
45.MM2, RHO=0.0009, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
570.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
10.30 KN-MET AT
570.MM, LOAD
14|
|
REQD STEEL=
147.MM2, RHO=0.0029, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

B E A M

N O. 11152 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


8.63 KNS Vc=
75.32 KNS Vs=
0.00 KNS
Tu=
1.23 KN-MET Tc=
1.1 KN-MET Ts=
1.6 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 304. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.53 SQ.CM.
AT END
SUPPORT - Vu=
9.84 KNS Vc=
40.66 KNS Vs=
0.00 KNS
Tu=
1.23 KN-MET Tc=
1.1 KN-MET Ts=
1.6 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 304. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.53 SQ.CM.

___5612J____________________
569X 200X 300_____________________5549J____
|
|
||=========================================================================||
| 2No10 H 257. | 0.TO 570 |
|
|
|
|
| 5*12c/c 94 |
|
|
|
5*12c/c 94
|
| 2No10 H 43. | 0.TO 570 |
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11153 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

680. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
680.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
5.53 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
78.MM2, RHO=0.0015, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|

Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
471.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
1.66 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
23.MM2, RHO=0.0004, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11153 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


3.30 KNS Vc=
42.40 KNS Vs=
Tu=
0.50 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
1.87 KNS Vc=
42.40 KNS Vs=
Tu=
0.50 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5613J____________________
679X 200X 300_____________________5620J____
|
|
||===================================================
|
| 2No10 H 257.
0.TO 471
|
|
|
| 2No10 H 43.
0.TO 680
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11154 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

680. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

43.

2 - 10MM

0.

680.

YES

YES

|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.55 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
64.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
414.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
0.78 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
11.MM2, RHO=0.0002, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11154 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


2.87 KNS Vc=
40.69 KNS Vs=
Tu=
0.44 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
1.45 KNS Vc=
40.43 KNS Vs=
Tu=
0.44 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5614J____________________
679X 200X 300_____________________5621J____
|
|
||=============================================
|
| 2No10 H 257.
0.TO 414
|
|
|
| 2No10 H 43.
0.TO 680
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11161 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

680. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
680.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
5.82 KN-MET AT
680.MM, LOAD
17|
|
REQD STEEL=
82.MM2, RHO=0.0016, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
181.
680.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
1.31 KN-MET AT
680.MM, LOAD
16|
|
REQD STEEL=
18.MM2, RHO=0.0004, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11161 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.28 KNS Vc=
42.38 KNS Vs=
Tu=
0.35 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
2.71 KNS Vc=
42.38 KNS Vs=
Tu=
0.35 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5620J____________________
680X 200X 300_____________________5627J____
|
|
|
=======================================================||
|
2No10 H 257. 181.TO 680
|
|
|
| 2No10 H 43.
0.TO 680
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11162 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

680. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
680.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.40 KN-MET AT
680.MM, LOAD
17|
|
REQD STEEL=
62.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
238.
680.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
0.94 KN-MET AT
680.MM, LOAD
16|
|
REQD STEEL=
13.MM2, RHO=0.0003, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11162 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.75 KNS Vc=
40.44 KNS Vs=
Tu=
0.53 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
3.17 KNS Vc=
40.76 KNS Vs=
Tu=
0.53 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5621J____________________
680X 200X 300_____________________5628J____
|
|
|
=================================================||
|
2No10 H 257. 238.TO 680
|
|
|
| 2No10 H 43.
0.TO 680
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11169 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

700. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
700.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.70 KN-MET AT
700.MM, LOAD
17|
|
REQD STEEL=
95.MM2, RHO=0.0018, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
700.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
8.96 KN-MET AT
700.MM, LOAD
16|
|
REQD STEEL=
127.MM2, RHO=0.0025, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11169 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


3.43 KNS Vc=
42.24 KNS Vs=
0.00 KNS
Tu=
1.39 KN-MET Tc=
1.1 KN-MET Ts=
1.9 KN-MET LOAD
15
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 369. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.61 SQ.CM.
AT END
SUPPORT - Vu=
4.52 KNS Vc=
42.24 KNS Vs=
0.00 KNS
Tu=
1.39 KN-MET Tc=
1.1 KN-MET Ts=
1.9 KN-MET LOAD
15
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 369. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.61 SQ.CM.

|
|
||=========================================================================||
| 2No10 H 257.
0.TO 700
|
|
|
|
|
| 5*12c/c 94|
|
|
|
|
5*12c/c 94
|
| 2No10 H 43.
0.TO 700
|
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11170 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

700. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
700.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.03 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
57.MM2, RHO=0.0011, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
700.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
7.68 KN-MET AT
700.MM, LOAD
16|
|
REQD STEEL=
109.MM2, RHO=0.0021, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11170 D E S I G N

AT START SUPPORT - Vu=


Tu=
1.68 KN-MET Tc=

6585.1 cm^4

R E S U L T S - SHEAR

3.98 KNS Vc=


40.95 KNS Vs=
1.1 KN-MET Ts=
2.2 KN-MET

0.00 KNS
LOAD
14

STIRRUPS ARE REQUIRED FOR TORSION.


REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 369. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

0.73 SQ.CM.

AT END
SUPPORT - Vu=
5.08 KNS Vc=
41.10 KNS Vs=
0.00 KNS
Tu=
1.68 KN-MET Tc=
1.1 KN-MET Ts=
2.2 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 369. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.73 SQ.CM.

___5628J____________________
700X 200X 300_____________________5550J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 700
|
|
|
|
|
| 5*12c/c 94|
|
|
|
|
5*12c/c 94
|
| 2No10 H 43.
0.TO 700
|
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11177 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.18 KN-MET AT
580.MM, LOAD
14|
|
REQD STEEL=
59.MM2, RHO=0.0011, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
9.97 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
142.MM2, RHO=0.0028, RHOMX=0.0191 RHOMN=0.0033 |

|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11177 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


6.60 KNS Vc=
40.79 KNS Vs=
0.00 KNS
Tu=
2.30 KN-MET Tc=
1.1 KN-MET Ts=
3.1 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 309. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.00 SQ.CM.
AT END
SUPPORT - Vu=
5.68 KNS Vc=
74.56 KNS Vs=
0.00 KNS
Tu=
2.30 KN-MET Tc=
1.1 KN-MET Ts=
3.1 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 309. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.00 SQ.CM.

___5548J____________________
579X 200X 300_____________________5634J____
|
|
||=========================================================================||
| 2No10 H 257. | 0.TO 580 |
|
|
|
|
| 5*12c/c 94 |
|
|
|
5*12c/c 94
|
| 2No10 H 43. | 0.TO 580 |
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN LEVEL

NO. 11178 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.63 KN-MET AT
532.MM, LOAD
14|
|
REQD STEEL=
65.MM2, RHO=0.0013, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
3.67 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
51.MM2, RHO=0.0010, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11178 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


4.11 KNS Vc=
45.35 KNS Vs=
0.00 KNS
Tu=
1.55 KN-MET Tc=
1.1 KN-MET Ts=
2.1 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 309. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.68 SQ.CM.
AT END
SUPPORT - Vu=
3.19 KNS Vc=
40.69 KNS Vs=
0.00 KNS
Tu=
1.55 KN-MET Tc=
1.1 KN-MET Ts=
2.1 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 309. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.68 SQ.CM.

___5634J____________________
579X 200X 300_____________________5635J____
|
|
||=========================================================================||
| 2No10 H 257. | 0.TO 580 |
|
|
|
|
| 5*12c/c 94 |
|
|
|
5*12c/c 94
|
| 2No10 H 43. | 0.TO 580 |
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11179 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.73 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
67.MM2, RHO=0.0013, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11179 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


2.01 KNS Vc=
40.50 KNS Vs=
Tu=
0.19 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
0.78 KNS Vc=
40.37 KNS Vs=
Tu=
0.19 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5635J____________________
580X 200X 300_____________________5636J____
|
|
|
|
|
|
|
|
| 2No10 H 43.
0.TO 580
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================

BEAM
LEN -

NO. 11180 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.43 KN-MET AT
0.MM, LOAD
13|
|
REQD STEEL=
62.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11180 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.97 KNS Vc=
40.45 KNS Vs=
Tu=
0.32 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
3.19 KNS Vc=
40.67 KNS Vs=
Tu=
0.32 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5636J____________________
580X 200X 300_____________________5637J____
|
|
|
|
|
|
|
|
| 2No10 H 43.
0.TO 580
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11181 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

580. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.08 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
57.MM2, RHO=0.0011, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
580.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
4.79 KN-MET AT
580.MM, LOAD
14|
|
REQD STEEL=
67.MM2, RHO=0.0013, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11181 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


5.81 KNS Vc=
40.95 KNS Vs=
Tu=
0.84 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
7.04 KNS Vc=
42.93 KNS Vs=
Tu=
0.84 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5637J____________________
579X 200X 300_____________________5638J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 580
|
|
|
| 2No10 H 43.
0.TO 580
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11182 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

570. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
570.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
3.06 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
43.MM2, RHO=0.0008, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
570.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
11.62 KN-MET AT
570.MM, LOAD
14|
|
REQD STEEL=
167.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11182 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


9.27 KNS Vc=
43.48 KNS Vs=
0.00 KNS
Tu=
1.35 KN-MET Tc=
1.1 KN-MET Ts=
1.8 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 304. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.59 SQ.CM.
AT END
SUPPORT - Vu=
10.47 KNS Vc=
40.62 KNS Vs=
0.00 KNS
Tu=
1.35 KN-MET Tc=
1.1 KN-MET Ts=
1.8 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 304. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.59 SQ.CM.

___5638J____________________
569X 200X 300_____________________5550J____
|
|
||=========================================================================||
| 2No12 H 256. | 0.TO 570 |
|
|
|
|
| 5*12c/c 94 |
|
|
|
5*12c/c 94
|
| 2No10 H 43. | 0.TO 570 |
|
|
|
|

||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11207 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
16.59 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
181.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
7.81 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
111.MM2, RHO=0.0022, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11207 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


44.62 KNS Vc=
41.85 KNS Vs=
17.64 KNS
Tu=
1.50 KN-MET Tc=
1.1 KN-MET Ts=
2.0 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.65 SQ.CM.
AT END

SUPPORT - Vu=

45.27 KNS

Vc=

41.85 KNS

Vs=

18.51 KNS

Tu=
1.50 KN-MET Tc=
1.1 KN-MET Ts=
2.0 KN-MET LOAD
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

14

0.65 SQ.CM.

___5587J____________________
400X 200X 300_____________________5639J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11210 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
14.90 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
8.21 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
116.MM2, RHO=0.0023, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

B E A M

N O. 11210 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


38.85 KNS Vc=
42.11 KNS Vs=
9.69 KNS
Tu=
0.66 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM
AT END
SUPPORT - Vu=
42.13 KNS Vc=
60.82 KNS Vs=
0.00 KNS
Tu=
0.66 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM

___5588J____________________
400X 200X 300_____________________5645J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400 |
|
|
| 3*12c/c129
|
|
3*12c/c129
|
| 2No12 H 44.
0.TO 400 |
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11213 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
13.94 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|

2
257.
4 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
22.52 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
248.MM2, RHO=0.0048, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11213 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


48.81 KNS Vc=
75.68 KNS Vs=
0.00 KNS
Tu=
2.47 KN-MET Tc=
1.2 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.08 SQ.CM.
AT END
SUPPORT - Vu=
49.46 KNS Vc=
41.84 KNS Vs=
24.10 KNS
Tu=
2.47 KN-MET Tc=
1.2 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.08 SQ.CM.

___5639J____________________
400X 200X 300_____________________5642J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM

NO. 11216 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

LEN -

420. MM

LEVEL

HEIGHT

FY -

412.

BAR INFO

FC -

25.
FROM

MPA, SIZE TO

200. X

300. MMS
ANCHOR

(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
26.55 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
295.MM2, RHO=0.0057, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

11687.7 cm^4

2
254.
3 - 16MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
46.13 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
547.MM2, RHO=0.0108, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./
54. MMS
|
|
REQD. DEVELOPMENT LENGTH =
709. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11216 D E S I G N

18747.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


53.05 KNS Vc=
43.65 KNS Vs=
27.09 KNS
Tu=
3.59 KN-MET Tc=
1.2 KN-MET Ts=
4.8 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.57 SQ.CM.
AT END
SUPPORT - Vu=
53.73 KNS Vc=
41.87 KNS Vs=
29.78 KNS
Tu=
3.59 KN-MET Tc=
1.2 KN-MET Ts=
4.8 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.57 SQ.CM.

___5642J____________________
419X 200X 300_____________________5555J____
|
|
||=========================================================================||
| 3No16 H 254.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 4No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
| 3#16
| | 3#16
| | 3#16
| | 3#16
| | 3#16
|
| 3#16
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11219 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
9.86 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
140.MM2, RHO=0.0027, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
3 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
21.09 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
231.MM2, RHO=0.0045, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
57. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11219 D E S I G N

9255.0 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


44.88 KNS Vc=
42.20 KNS Vs=
17.64 KNS
Tu=
1.53 KN-MET Tc=
1.1 KN-MET Ts=
2.0 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.67 SQ.CM.
AT END
SUPPORT - Vu=
48.15 KNS Vc=
42.20 KNS Vs=
22.00 KNS
Tu=
1.53 KN-MET Tc=
1.1 KN-MET Ts=
2.0 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.67 SQ.CM.

___5645J____________________
400X 200X 300_____________________5646J____
|
|
||=========================================================================||
| 3No10 H 257.
0.TO 400
|
|
| |

| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
| 3#10
| | 3#10
| | 3#10
| | 3#10
| | 3#10
|
| 3#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11220 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
18.58 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
203.MM2, RHO=0.0040, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
254.
3 - 16MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
44.40 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
524.MM2, RHO=0.0103, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./
54. MMS
|
|
REQD. DEVELOPMENT LENGTH =
709. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11220 D E S I G N

18747.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


51.34 KNS Vc=
42.12 KNS Vs=
26.34 KNS
Tu=
2.59 KN-MET Tc=
1.1 KN-MET Ts=
3.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.13 SQ.CM.

AT END
SUPPORT - Vu=
54.76 KNS Vc=
42.12 KNS Vs=
30.90 KNS
Tu=
2.59 KN-MET Tc=
1.1 KN-MET Ts=
3.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.13 SQ.CM.

___5646J____________________
419X 200X 300_____________________5556J____
|
|
||=========================================================================||
| 3No16 H 254.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
| 3#16
| | 3#16
| | 3#16
| | 3#16
| | 3#16
|
| 3#16
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11229 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
3 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
21.26 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
233.MM2, RHO=0.0045, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
57. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

9255.0 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
18.37 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
201.MM2, RHO=0.0039, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

B E A M

N O. 11229 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


6.85 KNS Vc=
41.79 KNS Vs=
0.00 KNS
Tu=
3.54 KN-MET Tc=
1.1 KN-MET Ts=
4.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.54 SQ.CM.
AT END
SUPPORT - Vu=
8.62 KNS Vc=
41.79 KNS Vs=
0.00 KNS
Tu=
3.54 KN-MET Tc=
1.1 KN-MET Ts=
4.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.54 SQ.CM.

___5655J____________________
420X 200X 300_____________________5665J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 3No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 3#10
| | 3#10
| | 3#10
| | 3#10
| | 3#10
|
| 3#10
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11232 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

250. X

400. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
18.28 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
187.MM2, RHO=0.0021, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 163. MMS
|

|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

18652.9 cm^4

2
357.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
13.45 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
137.MM2, RHO=0.0015, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 165. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11232 D E S I G N

13627.4 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


8.22 KNS Vc=
71.18 KNS Vs=
0.00 KNS
Tu=
5.00 KN-MET Tc=
2.5 KN-MET Ts=
6.7 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 132. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.58 SQ.CM.
AT END
SUPPORT - Vu=
9.35 KNS Vc=
70.75 KNS Vs=
0.00 KNS
Tu=
5.00 KN-MET Tc=
2.5 KN-MET Ts=
6.7 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 132. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.58 SQ.CM.

___5658J____________________
420X 250X 400_____________________5668J____
|
|
||=========================================================================||
| 2No10 H 357.
0.TO 420|
|
| |
| 3*12c/c132
|
|
3*12c/c132 | |
| 2No12 H 44.
0.TO 420|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================

BEAM
LEN -

NO. 11242 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
46.
2 - 16MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
30.31 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
344.MM2, RHO=0.0068, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|
|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

13828.1 cm^4

2
254.
2 - 16MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
32.70 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
374.MM2, RHO=0.0074, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|
|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11242 D E S I G N

13828.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


11.19 KNS Vc=
61.76 KNS Vs=
0.00 KNS
Tu=
6.21 KN-MET Tc=
1.1 KN-MET Ts=
8.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.70 SQ.CM.
AT END
SUPPORT - Vu=
12.99 KNS Vc=
44.08 KNS Vs=
0.00 KNS
Tu=
6.21 KN-MET Tc=
1.1 KN-MET Ts=
8.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.70 SQ.CM.

___5665J____________________
430X 200X 300_____________________5556J____
|
|
||=========================================================================||
| 2No16 H 254.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No16 H 46.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|

_________
|
|
|
oo
|
| 2#16
|
|
|
| 2#16
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#16
|
|
|
| 2#16
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#16
|
|
|
| 2#16
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#16
|
|
|
| 2#16
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#16
|
|
|
| 2#16
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#16
|
|
|
| 2#16
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11245 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

250. X

400. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
18.85 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
193.MM2, RHO=0.0022, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 163. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

18652.9 cm^4

2
357.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
26.38 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
271.MM2, RHO=0.0030, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
55. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11245 D E S I G N

24860.4 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


4.71 KNS Vc= 130.14 KNS Vs=
0.00 KNS
Tu=
4.23 KN-MET Tc=
2.4 KN-MET Ts=
5.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 132. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.33 SQ.CM.
AT END
SUPPORT - Vu=
5.87 KNS Vc= 130.14 KNS Vs=
Tu=
4.23 KN-MET Tc=
2.4 KN-MET Ts=
5.6 KN-MET
STIRRUPS ARE REQUIRED FOR TORSION.

0.00 KNS
LOAD
14

REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.


PROVIDE 12 MM 2-LEGGED STIRRUPS AT 132. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

1.33 SQ.CM.

___5668J____________________
430X 250X 400_____________________5544J____
|
|
||=========================================================================||
| 4No10 H 357.
0.TO 430|
|
| |
| 3*12c/c132
|
|
3*12c/c132 | |
| 2No12 H 44.
0.TO 430|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11264 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
14.10 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
10.48 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
149.MM2, RHO=0.0029, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

B E A M

N O. 11264 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


15.66 KNS Vc=
24.72 KNS Vs=
0.00 KNS
Tu=
2.37 KN-MET Tc=
0.4 KN-MET Ts=
3.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.03 SQ.CM.
AT END
SUPPORT - Vu=
17.43 KNS Vc=
24.72 KNS Vs=
0.00 KNS
Tu=
2.37 KN-MET Tc=
0.4 KN-MET Ts=
3.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.03 SQ.CM.

___5682J____________________
420X 200X 300_____________________5561J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11265 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
16.25 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
177.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|

Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
3.32 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
47.MM2, RHO=0.0009, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11265 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


2.14 KNS Vc=
40.67 KNS Vs=
0.00 KNS
Tu=
2.20 KN-MET Tc=
1.1 KN-MET Ts=
2.9 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.96 SQ.CM.
AT END
SUPPORT - Vu=
2.83 KNS Vc=
41.18 KNS Vs=
0.00 KNS
Tu=
2.20 KN-MET Tc=
1.1 KN-MET Ts=
2.9 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.96 SQ.CM.

___5683J____________________
420X 200X 300_____________________5567J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11275 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
19.56 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
215.MM2, RHO=0.0042, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
3 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
20.91 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
229.MM2, RHO=0.0045, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
57. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11275 D E S I G N

9255.0 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


8.90 KNS Vc=
41.42 KNS Vs=
0.00 KNS
Tu=
4.22 KN-MET Tc=
1.1 KN-MET Ts=
5.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.84 SQ.CM.
AT END
SUPPORT - Vu=
7.13 KNS Vc=
41.42 KNS Vs=
0.00 KNS
Tu=
4.22 KN-MET Tc=
1.1 KN-MET Ts=
5.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.84 SQ.CM.

___5691J____________________
419X 200X 300_____________________5682J____
|
|
||=========================================================================||
| 3No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|

| 3#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 3#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 3#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 3#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 3#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 3#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11276 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.12 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
101.MM2, RHO=0.0020, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
6.12 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
86.MM2, RHO=0.0017, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11276 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


0.47 KNS Vc=
37.26 KNS Vs=
0.00 KNS
Tu=
2.85 KN-MET Tc=
1.0 KN-MET Ts=
3.8 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.24 SQ.CM.
AT END
SUPPORT - Vu=
1.15 KNS Vc=
37.26 KNS Vs=
0.00 KNS
Tu=
2.85 KN-MET Tc=
1.0 KN-MET Ts=
3.8 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.24 SQ.CM.

___5692J____________________
419X 200X 300_____________________5683J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11289 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
19.15 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
210.MM2, RHO=0.0041, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
11.09 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
159.MM2, RHO=0.0031, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11289 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


13.90 KNS Vc=
41.98 KNS Vs=
0.00 KNS
Tu=
1.77 KN-MET Tc=
1.3 KN-MET Ts=
2.4 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.77 SQ.CM.
AT END
SUPPORT - Vu=
10.51 KNS Vc=
40.95 KNS Vs=
0.00 KNS
Tu=
1.77 KN-MET Tc=
1.3 KN-MET Ts=
2.4 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.77 SQ.CM.

___5700J____________________ 2249X 200X 300_____________________5587J____


|
|
||=========================================================================||
| 2No12 H 256.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11290 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
16.61 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
181.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =
2

256.

2 - 12MM

0.

2250.

8871.6 cm^4
YES

YES

|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
14.29 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11290 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


20.71 KNS Vc=
28.55 KNS Vs=
0.00 KNS
Tu=
3.14 KN-MET Tc=
0.6 KN-MET Ts=
4.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.37 SQ.CM.
AT END
SUPPORT - Vu=
3.64 KNS Vc=
28.55 KNS Vs=
0.00 KNS
Tu=
3.14 KN-MET Tc=
0.6 KN-MET Ts=
4.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.37 SQ.CM.

___5701J____________________ 2249X 200X 300_____________________5588J____


|
|
||=========================================================================||
| 2No12 H 256.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM

NO. 11345 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

LEN -

420. MM

LEVEL

HEIGHT
(MM)

FY -

412.

BAR INFO

FC -

25.
FROM
(MM)

MPA, SIZE TO
(MM)

200. X

300. MMS
ANCHOR
STA END

_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
16.36 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
178.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
3.28 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
46.MM2, RHO=0.0009, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11345 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


3.17 KNS Vc=
38.82 KNS Vs=
0.00 KNS
Tu=
1.75 KN-MET Tc=
1.0 KN-MET Ts=
2.3 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.76 SQ.CM.
AT END
SUPPORT - Vu=
3.85 KNS Vc=
38.82 KNS Vs=
0.00 KNS
Tu=
1.75 KN-MET Tc=
1.0 KN-MET Ts=
2.3 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.76 SQ.CM.

___5568J____________________
419X 200X 300_____________________5719J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11347 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
14.55 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
8.24 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
117.MM2, RHO=0.0023, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11347 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


20.43 KNS Vc=
88.63 KNS Vs=
0.00 KNS
Tu=
2.46 KN-MET Tc=
1.5 KN-MET Ts=
3.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.07 SQ.CM.
AT END
SUPPORT - Vu=
18.66 KNS Vc=
43.45 KNS Vs=
0.00 KNS
Tu=
2.46 KN-MET Tc=
1.5 KN-MET Ts=
3.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.07 SQ.CM.

___5582J____________________

419X 200X

300_____________________5720J____

|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11350 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
17.38 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
190.MM2, RHO=0.0037, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
7.62 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
108.MM2, RHO=0.0021, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11350 D E S I G N

AT START SUPPORT - Vu=


Tu=
1.40 KN-MET Tc=

6585.1 cm^4

R E S U L T S - SHEAR

44.10 KNS Vc=


39.38 KNS Vs=
1.0 KN-MET Ts=
1.9 KN-MET

19.43 KNS
LOAD
14

STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.


PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

0.61 SQ.CM.

AT END
SUPPORT - Vu=
44.76 KNS Vc=
39.38 KNS Vs=
20.30 KNS
Tu=
1.40 KN-MET Tc=
1.0 KN-MET Ts=
1.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.61 SQ.CM.

___5591J____________________
400X 200X 300_____________________5703J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11352 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
12.97 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
3 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
21.44 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
235.MM2, RHO=0.0046, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
57. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|

|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11352 D E S I G N

9255.0 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


48.60 KNS Vc=
41.64 KNS Vs=
23.16 KNS
Tu=
2.50 KN-MET Tc=
1.1 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.09 SQ.CM.
AT END
SUPPORT - Vu=
49.25 KNS Vc=
41.64 KNS Vs=
24.03 KNS
Tu=
2.50 KN-MET Tc=
1.1 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.09 SQ.CM.

___5703J____________________
400X 200X 300_____________________5704J____
|
|
||=========================================================================||
| 3No10 H 257.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
| 3#10
| | 3#10
| | 3#10
| | 3#10
| | 3#10
|
| 3#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11353 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
24.83 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
275.MM2, RHO=0.0053, RHOMX=0.0191 RHOMN=0.0033 |

|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

11687.7 cm^4

2
254.
3 - 16MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
44.93 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
531.MM2, RHO=0.0104, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./
54. MMS
|
|
REQD. DEVELOPMENT LENGTH =
709. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11353 D E S I G N

18747.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


52.79 KNS Vc=
42.25 KNS Vs=
28.14 KNS
Tu=
3.65 KN-MET Tc=
1.1 KN-MET Ts=
4.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.59 SQ.CM.
AT END
SUPPORT - Vu=
53.47 KNS Vc=
42.25 KNS Vs=
29.05 KNS
Tu=
3.65 KN-MET Tc=
1.1 KN-MET Ts=
4.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.59 SQ.CM.

___5704J____________________
419X 200X 300_____________________5579J____
|
|
||=========================================================================||
| 3No16 H 254.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 4No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
| 3#16
| | 3#16
| | 3#16
| | 3#16
| | 3#16
|
| 3#16
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================

LEN -

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
18.25 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
200.MM2, RHO=0.0039, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
7.76 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
110.MM2, RHO=0.0021, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11357 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


46.02 KNS Vc=
42.49 KNS Vs=
18.87 KNS
Tu=
0.93 KN-MET Tc=
1.2 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM
AT END
SUPPORT - Vu=
19.31 KNS Vc=
41.67 KNS Vs=
0.00 KNS
Tu=
0.03 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET LOAD
13
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM

___5592J____________________
400X 200X 300_____________________5709J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400 |
|
|
| 3*12c/c129
|
|
3*12c/c129
|
| 2No12 H 44.
0.TO 400 |
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

| 2#10
|
|
|
| 2#12
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11360 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
11.72 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
168.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
4 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
23.96 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
265.MM2, RHO=0.0051, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11360 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


52.64 KNS Vc=
74.59 KNS Vs=
0.00 KNS
Tu=
1.95 KN-MET Tc=
1.1 KN-MET Ts=
2.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.85 SQ.CM.
AT END
SUPPORT - Vu=
55.91 KNS Vc=
41.85 KNS Vs=
32.70 KNS
Tu=
1.95 KN-MET Tc=
1.1 KN-MET Ts=
2.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.85 SQ.CM.

___5709J____________________
400X 200X 300_____________________5710J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11361 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
3 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
21.38 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
235.MM2, RHO=0.0046, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
57. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

9255.0 cm^4

2
252.
2 - 20MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
50.89 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
619.MM2, RHO=0.0123, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
45./ 105. MMS
|
|
REQD. DEVELOPMENT LENGTH =
630. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11361 D E S I G N

18962.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


59.54 KNS Vc=
42.92 KNS Vs=
36.47 KNS
Tu=
3.14 KN-MET Tc=
1.1 KN-MET Ts=
4.2 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.37 SQ.CM.
AT END
SUPPORT - Vu=
62.96 KNS Vc=
41.58 KNS Vs=
42.37 KNS
Tu=
3.14 KN-MET Tc=
1.1 KN-MET Ts=
4.2 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.37 SQ.CM.

___5710J____________________
419X 200X 300_____________________5580J____
|
|
||=========================================================================||
| 2No20 H 252.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 3No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#20
| | 2#20
| | 2#20
| | 2#20
| | 2#20
|
| 2#20
|
|
| |
| |
| |
| |
|
|
|
| 3#10
| | 3#10
| | 3#10
| | 3#10
| | 3#10
|
| 3#10
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11371 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
13.62 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
8.53 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
121.MM2, RHO=0.0024, RHOMX=0.0191 RHOMN=0.0033 |

|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11371 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


19.43 KNS Vc=
24.55 KNS Vs=
1.36 KNS
Tu=
2.42 KN-MET Tc=
0.4 KN-MET Ts=
3.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.05 SQ.CM.
AT END
SUPPORT - Vu=
17.66 KNS Vc=
24.55 KNS Vs=
0.00 KNS
Tu=
2.42 KN-MET Tc=
0.4 KN-MET Ts=
3.2 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.05 SQ.CM.

___5581J____________________
420X 200X 300_____________________5737J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11372 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

43.

2 - 10MM

0.

420.

YES

YES

|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.74 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
95.MM2, RHO=0.0019, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
6.56 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
93.MM2, RHO=0.0018, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11372 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


0.99 KNS Vc=
78.16 KNS Vs=
0.00 KNS
Tu=
2.80 KN-MET Tc=
1.2 KN-MET Ts=
3.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.22 SQ.CM.
AT END
SUPPORT - Vu=
0.31 KNS Vc=
78.16 KNS Vs=
0.00 KNS
Tu=
2.80 KN-MET Tc=
1.2 KN-MET Ts=
3.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.22 SQ.CM.

___5719J____________________
420X 200X 300_____________________5728J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11373 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
21.63 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
238.MM2, RHO=0.0046, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

11687.7 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
19.20 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
211.MM2, RHO=0.0041, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11373 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


7.26 KNS Vc=
42.23 KNS Vs=
0.00 KNS
Tu=
4.34 KN-MET Tc=
1.1 KN-MET Ts=
5.8 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.89 SQ.CM.
AT END
SUPPORT - Vu=
9.03 KNS Vc=
42.23 KNS Vs=
0.00 KNS
Tu=
4.34 KN-MET Tc=
1.1 KN-MET Ts=
5.8 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.89 SQ.CM.

___5720J____________________
420X 200X 300_____________________5729J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |

| 4No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11383 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
15.19 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
25.10 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
278.MM2, RHO=0.0054, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11383 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


41.50 KNS Vc=
35.98 KNS Vs=
19.35 KNS
Tu=
4.70 KN-MET Tc=
0.9 KN-MET Ts=
6.3 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.05 SQ.CM.

AT END
SUPPORT - Vu=
42.19 KNS Vc=
35.98 KNS Vs=
20.28 KNS
Tu=
4.70 KN-MET Tc=
0.9 KN-MET Ts=
6.3 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.05 SQ.CM.

___5728J____________________
430X 200X 300_____________________5520J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11384 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
3 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
28.93 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
325.MM2, RHO=0.0063, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./
56. MMS
|
|
REQD. DEVELOPMENT LENGTH =
384. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

12316.4 cm^4

2
254.
2 - 16MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
33.06 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
378.MM2, RHO=0.0074, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|
|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

13828.1 cm^4

B E A M

N O. 11384 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


11.96 KNS Vc=
42.10 KNS Vs=
0.00 KNS
Tu=
7.40 KN-MET Tc=
1.1 KN-MET Ts=
9.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
3.22 SQ.CM.
AT END
SUPPORT - Vu=
13.77 KNS Vc=
42.10 KNS Vs=
0.00 KNS
Tu=
7.40 KN-MET Tc=
1.1 KN-MET Ts=
9.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
3.22 SQ.CM.

___5729J____________________
430X 200X 300_____________________5580J____
|
|
||=========================================================================||
| 2No16 H 254.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 3No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#16
| | 2#16
| | 2#16
| | 2#16
| | 2#16
|
| 2#16
|
|
| |
| |
| |
| |
|
|
|
| 3#12
| | 3#12
| | 3#12
| | 3#12
| | 3#12
|
| 3#12
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11394 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
20.31 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
222.MM2, RHO=0.0043, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|

|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8946.9 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
20.12 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
220.MM2, RHO=0.0043, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11394 D E S I G N

8946.9 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


8.22 KNS Vc=
41.70 KNS Vs=
0.00 KNS
Tu=
4.20 KN-MET Tc=
1.1 KN-MET Ts=
5.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.83 SQ.CM.
AT END
SUPPORT - Vu=
9.99 KNS Vc=
49.35 KNS Vs=
0.00 KNS
Tu=
4.20 KN-MET Tc=
1.1 KN-MET Ts=
5.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.83 SQ.CM.

___5737J____________________
419X 200X 300_____________________5741J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================

LEN -

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
27.23 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
304.MM2, RHO=0.0059, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

11588.0 cm^4

2
254.
2 - 16MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
34.61 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
394.MM2, RHO=0.0077, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|
|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11399 D E S I G N

14071.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


12.81 KNS Vc=
68.13 KNS Vs=
0.00 KNS
Tu=
7.03 KN-MET Tc=
1.1 KN-MET Ts=
9.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
3.06 SQ.CM.
AT END
SUPPORT - Vu=
14.61 KNS Vc=
43.81 KNS Vs=
0.00 KNS
Tu=
7.03 KN-MET Tc=
1.1 KN-MET Ts=
9.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
3.06 SQ.CM.

___5741J____________________
430X 200X 300_____________________5579J____
|
|
||=========================================================================||
| 2No16 H 254.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 4No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________

|
|
|
oo
|
| 2#16
|
|
|
| 4#10
|
| oooo
|
|
|
|_________|

|
|
|
oo
|
| 2#16
|
|
|
| 4#10
|
| oooo
|
|
|
|_________|

|
|
|
oo
|
| 2#16
|
|
|
| 4#10
|
| oooo
|
|
|
|_________|

|
|
|
oo
|
| 2#16
|
|
|
| 4#10
|
| oooo
|
|
|
|_________|

|
|
|
oo
|
| 2#16
|
|
|
| 4#10
|
| oooo
|
|
|
|_________|

|
|
|
oo
|
| 2#16
|
|
|
| 4#10
|
| oooo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11442 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
19.80 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
217.MM2, RHO=0.0042, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
14.97 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11442 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


15.69 KNS Vc=
42.30 KNS Vs=
0.00 KNS
Tu=
2.91 KN-MET Tc=
1.5 KN-MET Ts=
3.9 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.27 SQ.CM.
AT END
SUPPORT - Vu=
12.30 KNS Vc=
41.54 KNS Vs=
Tu=
2.91 KN-MET Tc=
1.5 KN-MET Ts=
3.9 KN-MET
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

0.00 KNS
LOAD
17

PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM


ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

1.27 SQ.CM.

___5745J____________________ 2249X 200X 300_____________________5591J____


|
|
||=========================================================================||
| 2No12 H 256.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11443 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
20.48 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
224.MM2, RHO=0.0044, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8946.9 cm^4

2
256.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
15.26 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

B E A M

N O. 11443 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


22.28 KNS Vc=
26.86 KNS Vs=
2.85 KNS
Tu=
2.88 KN-MET Tc=
0.5 KN-MET Ts=
3.8 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.25 SQ.CM.
AT END
SUPPORT - Vu=
5.22 KNS Vc=
26.86 KNS Vs=
0.00 KNS
Tu=
2.88 KN-MET Tc=
0.5 KN-MET Ts=
3.8 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.25 SQ.CM.

___5746J____________________ 2249X 200X 300_____________________5592J____


|
|
||=========================================================================||
| 2No12 H 256.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11455 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
15.51 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
0.81 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
11.MM2, RHO=0.0002, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11455 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


4.29 KNS Vc=
41.27 KNS Vs=
0.00 KNS
Tu=
2.19 KN-MET Tc=
1.2 KN-MET Ts=
2.9 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.95 SQ.CM.
AT END
SUPPORT - Vu=
3.61 KNS Vc=
40.74 KNS Vs=
0.00 KNS
Tu=
2.19 KN-MET Tc=
1.2 KN-MET Ts=
2.9 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.95 SQ.CM.

___5755J____________________
420X 200X 300_____________________5569J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM

NO. 11460 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

LEN -

420. MM

LEVEL

HEIGHT

FY -

412.

BAR INFO

FC -

25.
FROM

MPA, SIZE TO

200. X

300. MMS
ANCHOR

(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.58 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
93.MM2, RHO=0.0018, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
5.79 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
82.MM2, RHO=0.0016, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11460 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.94 KNS Vc=
37.87 KNS Vs=
0.00 KNS
Tu=
2.96 KN-MET Tc=
1.0 KN-MET Ts=
3.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.29 SQ.CM.
AT END
SUPPORT - Vu=
1.26 KNS Vc=
37.87 KNS Vs=
0.00 KNS
Tu=
2.96 KN-MET Tc=
1.0 KN-MET Ts=
3.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.29 SQ.CM.

___5760J____________________
419X 200X 300_____________________5755J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11482 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
19.39 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
213.MM2, RHO=0.0042, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
13.63 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11482 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


20.89 KNS Vc=
29.54 KNS Vs=
0.00 KNS
Tu=
2.51 KN-MET Tc=
0.7 KN-MET Ts=
3.3 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.09 SQ.CM.
AT END
SUPPORT - Vu=
3.82 KNS Vc=
29.54 KNS Vs=
0.00 KNS
Tu=
2.51 KN-MET Tc=
0.7 KN-MET Ts=
3.3 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.09 SQ.CM.

___5765J____________________ 2249X 200X 300_____________________5596J____


|
|
||=========================================================================||
| 2No12 H 256.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11483 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
17.80 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
195.MM2, RHO=0.0038, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
13.43 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11483 D E S I G N

AT START SUPPORT - Vu=

14.64 KNS

Vc=

8871.6 cm^4

R E S U L T S - SHEAR

42.08 KNS

Vs=

0.00 KNS

Tu=
2.80 KN-MET Tc=
1.4 KN-MET Ts=
3.7 KN-MET LOAD
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

17

1.22 SQ.CM.

AT END
SUPPORT - Vu=
11.25 KNS Vc=
41.26 KNS Vs=
0.00 KNS
Tu=
2.80 KN-MET Tc=
1.4 KN-MET Ts=
3.7 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.22 SQ.CM.

___5766J____________________ 2249X 200X 300_____________________5595J____


|
|
||=========================================================================||
| 2No12 H 256.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11486 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
15.50 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
6.04 KN-MET AT
0.MM, LOAD
15|

|
REQD STEEL=
85.MM2, RHO=0.0017, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11486 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


39.84 KNS Vc=
40.50 KNS Vs=
12.63 KNS
Tu=
1.29 KN-MET Tc=
1.1 KN-MET Ts=
1.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.56 SQ.CM.
AT END
SUPPORT - Vu=
40.50 KNS Vc=
40.50 KNS Vs=
13.50 KNS
Tu=
1.29 KN-MET Tc=
1.1 KN-MET Ts=
1.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.56 SQ.CM.

___5595J____________________
400X 200X 300_____________________5775J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11489 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

44.

2 - 12MM

0.

400.

YES

YES

|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
17.21 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
188.MM2, RHO=0.0037, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
6.79 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
96.MM2, RHO=0.0019, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11489 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


42.91 KNS Vc=
42.34 KNS Vs=
14.88 KNS
Tu=
0.89 KN-MET Tc=
1.2 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM
AT END
SUPPORT - Vu=
19.59 KNS Vc=
41.97 KNS Vs=
0.00 KNS
Tu=
0.09 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET LOAD
13
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM

___5596J____________________
400X 200X 300_____________________5781J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400 |
|
|
| 3*12c/c129
|
|
3*12c/c129
|
| 2No12 H 44.
0.TO 400 |
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11499 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
12.42 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
7.20 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
102.MM2, RHO=0.0020, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11499 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


17.68 KNS Vc=
26.89 KNS Vs=
0.00 KNS
Tu=
2.23 KN-MET Tc=
0.5 KN-MET Ts=
3.0 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.97 SQ.CM.
AT END
SUPPORT - Vu=
15.92 KNS Vc=
26.89 KNS Vs=
0.00 KNS
Tu=
2.23 KN-MET Tc=
0.5 KN-MET Ts=
3.0 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.97 SQ.CM.

___5563J____________________
420X 200X 300_____________________5801J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||

|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11500 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
10.86 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
155.MM2, RHO=0.0030, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6530.3 cm^4

2
256.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
19.61 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
215.MM2, RHO=0.0042, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11500 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


43.95 KNS Vc=
71.40 KNS Vs=
0.00 KNS
Tu=
2.30 KN-MET Tc=
1.1 KN-MET Ts=
3.1 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.00 SQ.CM.
AT END

SUPPORT - Vu=

44.60 KNS

Vc=

41.83 KNS

Vs=

17.64 KNS

Tu=
2.30 KN-MET Tc=
1.1 KN-MET Ts=
3.1 KN-MET LOAD
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

14

1.00 SQ.CM.

___5775J____________________
400X 200X 300_____________________5776J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11501 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
20.54 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
225.MM2, RHO=0.0044, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8946.9 cm^4

2
254.
3 - 16MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
40.94 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
479.MM2, RHO=0.0094, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./
54. MMS
|
|
REQD. DEVELOPMENT LENGTH =
709. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

18747.7 cm^4

B E A M

N O. 11501 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


47.89 KNS Vc=
42.61 KNS Vs=
21.25 KNS
Tu=
3.35 KN-MET Tc=
1.1 KN-MET Ts=
4.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.46 SQ.CM.
AT END
SUPPORT - Vu=
48.57 KNS Vc=
41.32 KNS Vs=
23.44 KNS
Tu=
3.35 KN-MET Tc=
1.1 KN-MET Ts=
4.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.46 SQ.CM.

___5776J____________________
419X 200X 300_____________________5557J____
|
|
||=========================================================================||
| 3No16 H 254.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
| 3#16
| | 3#16
| | 3#16
| | 3#16
| | 3#16
|
| 3#16
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11506 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
9.62 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
137.MM2, RHO=0.0027, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
4 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
22.24 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
245.MM2, RHO=0.0048, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11506 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


49.08 KNS Vc=
74.95 KNS Vs=
0.00 KNS
Tu=
1.82 KN-MET Tc=
1.1 KN-MET Ts=
2.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.79 SQ.CM.
AT END
SUPPORT - Vu=
52.35 KNS Vc=
41.71 KNS Vs=
28.09 KNS
Tu=
1.82 KN-MET Tc=
1.1 KN-MET Ts=
2.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.79 SQ.CM.

___5781J____________________
400X 200X 300_____________________5782J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM

NO. 11507 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

LEN -

420. MM

LEVEL

HEIGHT

FY -

412.

BAR INFO

FC -

25.
FROM

MPA, SIZE TO

200. X

300. MMS
ANCHOR

(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
17.43 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
190.MM2, RHO=0.0037, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
254.
3 - 16MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
47.47 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
566.MM2, RHO=0.0111, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./
54. MMS
|
|
REQD. DEVELOPMENT LENGTH =
709. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11507 D E S I G N

18747.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


55.68 KNS Vc=
42.29 KNS Vs=
31.95 KNS
Tu=
2.94 KN-MET Tc=
1.1 KN-MET Ts=
3.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.28 SQ.CM.
AT END
SUPPORT - Vu=
59.10 KNS Vc=
41.19 KNS Vs=
37.61 KNS
Tu=
2.94 KN-MET Tc=
1.1 KN-MET Ts=
3.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.28 SQ.CM.

___5782J____________________
419X 200X 300_____________________5558J____
|
|
||=========================================================================||
| 3No16 H 254.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
| 3#16
| | 3#16
| | 3#16
| | 3#16
| | 3#16
|
| 3#16
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11508 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
19.21 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
211.MM2, RHO=0.0041, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
17.35 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
190.MM2, RHO=0.0037, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11508 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


7.28 KNS Vc=
42.25 KNS Vs=
0.00 KNS
Tu=
3.91 KN-MET Tc=
1.1 KN-MET Ts=
5.2 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.70 SQ.CM.
AT END
SUPPORT - Vu=
9.05 KNS Vc=
42.25 KNS Vs=
0.00 KNS
Tu=
3.91 KN-MET Tc=
1.1 KN-MET Ts=
5.2 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.70 SQ.CM.

___5783J____________________
|

420X 200X

300_____________________5792J____
|

||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11509 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.27 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
89.MM2, RHO=0.0017, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
6.04 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
85.MM2, RHO=0.0017, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11509 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


1.07 KNS Vc=
77.62 KNS Vs=
Tu=
2.65 KN-MET Tc=
1.2 KN-MET Ts=
3.5 KN-MET
STIRRUPS ARE REQUIRED FOR TORSION.

0.00 KNS
LOAD
14

REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.


PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

1.16 SQ.CM.

AT END
SUPPORT - Vu=
1.75 KNS Vc=
77.62 KNS Vs=
0.00 KNS
Tu=
2.65 KN-MET Tc=
1.2 KN-MET Ts=
3.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.16 SQ.CM.

___5784J____________________
420X 200X 300_____________________5793J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11519 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
25.13 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
278.MM2, RHO=0.0054, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

11687.7 cm^4

2
254.
2 - 16MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
30.07 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
342.MM2, RHO=0.0067, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|

|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11519 D E S I G N

13828.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


11.92 KNS Vc=
42.39 KNS Vs=
0.00 KNS
Tu=
6.78 KN-MET Tc=
1.1 KN-MET Ts=
9.0 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.96 SQ.CM.
AT END
SUPPORT - Vu=
13.73 KNS Vc=
42.39 KNS Vs=
0.00 KNS
Tu=
6.78 KN-MET Tc=
1.1 KN-MET Ts=
9.0 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.96 SQ.CM.

___5792J____________________
430X 200X 300_____________________5558J____
|
|
||=========================================================================||
| 2No16 H 254.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 4No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#16
| | 2#16
| | 2#16
| | 2#16
| | 2#16
|
| 2#16
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11520 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

44.

2 - 12MM

0.

430.

YES

YES

|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
11.54 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
166.MM2, RHO=0.0032, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
23.12 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
255.MM2, RHO=0.0050, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11520 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


38.39 KNS Vc=
37.35 KNS Vs=
13.84 KNS
Tu=
4.74 KN-MET Tc=
1.0 KN-MET Ts=
6.3 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.07 SQ.CM.
AT END
SUPPORT - Vu=
39.09 KNS Vc=
37.35 KNS Vs=
14.76 KNS
Tu=
4.74 KN-MET Tc=
1.0 KN-MET Ts=
6.3 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.07 SQ.CM.

___5793J____________________
430X 200X 300_____________________5524J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11530 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
18.47 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
202.MM2, RHO=0.0039, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
17.90 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
196.MM2, RHO=0.0038, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11530 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


7.30 KNS Vc=
41.48 KNS Vs=
0.00 KNS
Tu=
3.94 KN-MET Tc=
1.1 KN-MET Ts=
5.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.72 SQ.CM.
AT END
SUPPORT - Vu=
9.06 KNS Vc=
46.93 KNS Vs=
0.00 KNS
Tu=
3.94 KN-MET Tc=
1.1 KN-MET Ts=
5.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.72 SQ.CM.

___5801J____________________
419X 200X 300_____________________5805J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||

|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11580 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
17.29 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
189.MM2, RHO=0.0037, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
12.22 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11580 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


19.76 KNS Vc=
32.71 KNS Vs=
0.00 KNS
Tu=
2.12 KN-MET Tc=
0.8 KN-MET Ts=
2.8 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.92 SQ.CM.
AT END

SUPPORT - Vu=

2.70 KNS

Vc=

32.71 KNS

Vs=

0.00 KNS

Tu=
2.12 KN-MET Tc=
0.8 KN-MET Ts=
2.8 KN-MET LOAD
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

16

0.92 SQ.CM.

___5809J____________________ 2249X 200X 300_____________________5604J____


|
|
||=========================================================================||
| 2No12 H 256.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11581 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
15.05 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
11.56 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
166.MM2, RHO=0.0032, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

B E A M

N O. 11581 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


13.28 KNS Vc=
41.76 KNS Vs=
0.00 KNS
Tu=
2.58 KN-MET Tc=
1.3 KN-MET Ts=
3.4 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.12 SQ.CM.
AT END
SUPPORT - Vu=
9.89 KNS Vc=
40.98 KNS Vs=
0.00 KNS
Tu=
2.58 KN-MET Tc=
1.3 KN-MET Ts=
3.4 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.12 SQ.CM.

___5810J____________________ 2249X 200X 300_____________________5603J____


|
|
||=========================================================================||
| 2No12 H 256.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11590 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
14.15 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|

|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11590 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


5.24 KNS Vc=
41.61 KNS Vs=
0.00 KNS
Tu=
1.98 KN-MET Tc=
1.2 KN-MET Ts=
2.6 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.86 SQ.CM.
AT END
SUPPORT - Vu=
4.55 KNS Vc=
40.85 KNS Vs=
0.00 KNS
Tu=
1.98 KN-MET Tc=
1.2 KN-MET Ts=
2.6 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.86 SQ.CM.

___5819J____________________
420X 200X 300_____________________5571J____
|
|
|
|
|
|
| 4*12c/c 94
4*12c/c 94
|
| 2No12 H 44.
0.TO 420
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11595 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|

|
CRITICAL POS MOMENT=
6.08 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
86.MM2, RHO=0.0017, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
4.82 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
68.MM2, RHO=0.0013, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11595 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


3.05 KNS Vc=
38.64 KNS Vs=
0.00 KNS
Tu=
2.80 KN-MET Tc=
1.0 KN-MET Ts=
3.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.22 SQ.CM.
AT END
SUPPORT - Vu=
2.37 KNS Vc=
38.64 KNS Vs=
0.00 KNS
Tu=
2.80 KN-MET Tc=
1.0 KN-MET Ts=
3.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.22 SQ.CM.

___5824J____________________
419X 200X 300_____________________5819J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11616 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
12.96 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
3.55 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
50.MM2, RHO=0.0010, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11616 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


33.14 KNS Vc=
41.13 KNS Vs=
3.06 KNS
Tu=
1.13 KN-MET Tc=
1.1 KN-MET Ts=
1.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.49 SQ.CM.
AT END
SUPPORT - Vu=
33.79 KNS Vc=
41.13 KNS Vs=
3.93 KNS
Tu=
1.13 KN-MET Tc=
1.1 KN-MET Ts=
1.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.49 SQ.CM.

___5603J____________________
400X 200X 300_____________________5838J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 400
|
|
| |
||=========================================================================||
|
|

|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11619 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
15.25 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
4.58 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
64.MM2, RHO=0.0013, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11619 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


37.20 KNS Vc=
42.12 KNS Vs=
7.48 KNS
Tu=
0.74 KN-MET Tc=
1.2 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM
AT END
SUPPORT - Vu=
19.78 KNS Vc=
41.82 KNS Vs=
Tu=
0.12 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
NO STIRRUPS ARE REQUIRED FOR TORSION.

0.00 KNS
LOAD
13

REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.


PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR

219. MM

___5604J____________________
400X 200X 300_____________________5844J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400 |
|
|
| 3*12c/c129
|
|
3*12c/c129
|
| 2No12 H 44.
0.TO 400 |
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11631 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
10.65 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
152.MM2, RHO=0.0030, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6530.3 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
5.37 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
76.MM2, RHO=0.0015, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

B E A M

N O. 11631 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


14.68 KNS Vc=
30.68 KNS Vs=
0.00 KNS
Tu=
1.92 KN-MET Tc=
0.7 KN-MET Ts=
2.6 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.84 SQ.CM.
AT END
SUPPORT - Vu=
12.91 KNS Vc=
30.68 KNS Vs=
0.00 KNS
Tu=
1.92 KN-MET Tc=
0.7 KN-MET Ts=
2.6 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.84 SQ.CM.

___5585J____________________
420X 200X 300_____________________5864J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11633 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
11.63 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
167.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
5.82 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
82.MM2, RHO=0.0016, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11633 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


14.43 KNS Vc=
85.10 KNS Vs=
0.00 KNS
Tu=
2.22 KN-MET Tc=
1.4 KN-MET Ts=
3.0 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.97 SQ.CM.
AT END
SUPPORT - Vu=
12.67 KNS Vc=
42.50 KNS Vs=
0.00 KNS
Tu=
2.22 KN-MET Tc=
1.4 KN-MET Ts=
3.0 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.97 SQ.CM.

___5586J____________________
419X 200X 300_____________________5847J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11634 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.67 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
109.MM2, RHO=0.0021, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
16.32 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
178.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11634 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


36.60 KNS Vc=
67.74 KNS Vs=
0.00 KNS
Tu=
1.99 KN-MET Tc=
1.1 KN-MET Ts=
2.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.87 SQ.CM.
AT END
SUPPORT - Vu=
37.25 KNS Vc=
41.38 KNS Vs=
8.29 KNS
Tu=
1.99 KN-MET Tc=
1.1 KN-MET Ts=
2.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.87 SQ.CM.

___5838J____________________
400X 200X 300_____________________5839J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

| 2#10
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11635 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
13.99 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
254.
2 - 16MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
34.20 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
389.MM2, RHO=0.0076, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|
|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11635 D E S I G N

14071.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


40.11 KNS Vc=
42.05 KNS Vs=
11.43 KNS
Tu=
2.89 KN-MET Tc=
1.1 KN-MET Ts=
3.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.26 SQ.CM.
AT END
SUPPORT - Vu=
40.79 KNS Vc=
41.05 KNS Vs=
13.34 KNS
Tu=
2.89 KN-MET Tc=
1.1 KN-MET Ts=
3.9 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.26 SQ.CM.

___5839J____________________
|

419X 200X

300_____________________5583J____
|

||=========================================================================||
| 2No16 H 254.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#16
| | 2#16
| | 2#16
| | 2#16
| | 2#16
|
| 2#16
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11640 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.58 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
93.MM2, RHO=0.0018, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
19.17 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
210.MM2, RHO=0.0041, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11640 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


42.70 KNS Vc=
75.11 KNS Vs=
Tu=
1.51 KN-MET Tc=
1.1 KN-MET Ts=
2.0 KN-MET
STIRRUPS ARE REQUIRED FOR TORSION.

0.00 KNS
LOAD
14

REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.


PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

0.66 SQ.CM.

AT END
SUPPORT - Vu=
45.97 KNS Vc=
41.29 KNS Vs=
20.01 KNS
Tu=
1.51 KN-MET Tc=
1.1 KN-MET Ts=
2.0 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.66 SQ.CM.

___5844J____________________
400X 200X 300_____________________5845J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11641 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
11.27 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
161.MM2, RHO=0.0031, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
254.
3 - 16MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
41.39 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
485.MM2, RHO=0.0095, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./
54. MMS
|
|
REQD. DEVELOPMENT LENGTH =
709. MMS
|

|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11641 D E S I G N

18747.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


48.87 KNS Vc=
42.01 KNS Vs=
23.14 KNS
Tu=
2.50 KN-MET Tc=
1.1 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.09 SQ.CM.
AT END
SUPPORT - Vu=
52.29 KNS Vc=
41.05 KNS Vs=
28.67 KNS
Tu=
2.50 KN-MET Tc=
1.1 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.09 SQ.CM.

___5845J____________________
419X 200X 300_____________________5584J____
|
|
||=========================================================================||
| 3No16 H 254.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
ooo
| |
ooo
| |
ooo
| |
ooo
| |
ooo
|
|
ooo
|
| 3#16
| | 3#16
| | 3#16
| | 3#16
| | 3#16
|
| 3#16
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11642 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
5.85 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
83.MM2, RHO=0.0016, RHOMX=0.0191 RHOMN=0.0033 |

|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
4.79 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
67.MM2, RHO=0.0013, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11642 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


2.19 KNS Vc=
77.03 KNS Vs=
0.00 KNS
Tu=
2.47 KN-MET Tc=
1.2 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.08 SQ.CM.
AT END
SUPPORT - Vu=
2.87 KNS Vc=
77.03 KNS Vs=
0.00 KNS
Tu=
2.47 KN-MET Tc=
1.2 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.08 SQ.CM.

___5846J____________________
420X 200X 300_____________________5855J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================

BEAM
LEN -

NO. 11643 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
16.03 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
174.MM2, RHO=0.0034, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
14.37 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11643 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


6.74 KNS Vc=
41.29 KNS Vs=
0.00 KNS
Tu=
3.29 KN-MET Tc=
1.1 KN-MET Ts=
4.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.44 SQ.CM.
AT END
SUPPORT - Vu=
8.51 KNS Vc=
46.01 KNS Vs=
0.00 KNS
Tu=
3.29 KN-MET Tc=
1.1 KN-MET Ts=
4.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.44 SQ.CM.

___5847J____________________
420X 200X 300_____________________5856J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|

|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11653 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.86 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
111.MM2, RHO=0.0022, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
19.51 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
214.MM2, RHO=0.0042, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11653 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


32.89 KNS Vc=
38.57 KNS Vs=
5.28 KNS
Tu=
4.44 KN-MET Tc=
1.0 KN-MET Ts=
5.9 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.94 SQ.CM.
AT END
SUPPORT - Vu=
33.59 KNS Vc=
38.57 KNS Vs=
Tu=
4.44 KN-MET Tc=
1.0 KN-MET Ts=
5.9 KN-MET
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.

6.21 KNS
LOAD
16

PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM


ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

1.94 SQ.CM.

___5855J____________________
430X 200X 300_____________________5528J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11664 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
15.49 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
14.80 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

B E A M

N O. 11664 D E S I G N

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


6.49 KNS Vc=
41.28 KNS Vs=
0.00 KNS
Tu=
3.39 KN-MET Tc=
1.1 KN-MET Ts=
4.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.48 SQ.CM.
AT END
SUPPORT - Vu=
8.26 KNS Vc=
46.26 KNS Vs=
0.00 KNS
Tu=
3.39 KN-MET Tc=
1.1 KN-MET Ts=
4.5 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.48 SQ.CM.

___5864J____________________
419X 200X 300_____________________5868J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11669 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
20.30 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
222.MM2, RHO=0.0043, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|

2
257.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
26.84 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
298.MM2, RHO=0.0058, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11669 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


10.36 KNS Vc=
53.29 KNS Vs=
0.00 KNS
Tu=
5.52 KN-MET Tc=
1.1 KN-MET Ts=
7.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.41 SQ.CM.
AT END
SUPPORT - Vu=
12.16 KNS Vc=
42.93 KNS Vs=
0.00 KNS
Tu=
5.52 KN-MET Tc=
1.1 KN-MET Ts=
7.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.41 SQ.CM.

___5868J____________________
430X 200X 300_____________________5583J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11720 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
12.47 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11720 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


7.23 KNS Vc=
41.86 KNS Vs=
0.00 KNS
Tu=
1.64 KN-MET Tc=
1.2 KN-MET Ts=
2.2 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.72 SQ.CM.
AT END
SUPPORT - Vu=
6.55 KNS Vc=
40.94 KNS Vs=
0.00 KNS
Tu=
1.64 KN-MET Tc=
1.2 KN-MET Ts=
2.2 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.72 SQ.CM.

___5880J____________________
420X 200X 300_____________________5573J____
|
|
|
|
|
|
| 4*12c/c 94
4*12c/c 94
|
| 2No12 H 44.
0.TO 420
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================

BEAM
LEN -

NO. 11725 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
5.57 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
79.MM2, RHO=0.0015, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
2.95 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
41.MM2, RHO=0.0008, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11725 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


4.63 KNS Vc=
39.68 KNS Vs=
0.00 KNS
Tu=
2.58 KN-MET Tc=
1.0 KN-MET Ts=
3.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.13 SQ.CM.
AT END
SUPPORT - Vu=
3.95 KNS Vc=
39.68 KNS Vs=
0.00 KNS
Tu=
2.58 KN-MET Tc=
1.0 KN-MET Ts=
3.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.13 SQ.CM.

___5885J____________________
419X 200X 300_____________________5880J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|

_________
|
|
|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
|
oo
|
| 2#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11747 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
11.39 KN-MET AT 2250.MM, LOAD
17|
|
REQD STEEL=
163.MM2, RHO=0.0032, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
2250.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
8.21 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
116.MM2, RHO=0.0023, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11747 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


10.41 KNS Vc=
41.55 KNS Vs=
0.00 KNS
Tu=
2.09 KN-MET Tc=
1.2 KN-MET Ts=
2.8 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.91 SQ.CM.
AT END
SUPPORT - Vu=
7.01 KNS Vc=
40.75 KNS Vs=
Tu=
2.09 KN-MET Tc=
1.2 KN-MET Ts=
2.8 KN-MET
STIRRUPS ARE REQUIRED FOR TORSION.

0.00 KNS
LOAD
17

REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.


PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

0.91 SQ.CM.

___5891J____________________ 2249X 200X 300_____________________5599J____


|
|
||=========================================================================||
| 2No10 H 257.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
| 14*12c/c 94 |
|
|
|
|
|
|
|
|
|
|
| 14*12c/c 94 | |
| 2No12 H |44.| 0.TO 2250|
|
|
|
|
|
|
|
|
|
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11748 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

2250. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
195.
2250.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
14.33 KN-MET AT 2250.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
1051.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
9.03 KN-MET AT
0.MM, LOAD
13|
|
REQD STEEL=
128.MM2, RHO=0.0025, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

3
257.
2 - 10MM
1668.
2250.
NO
YES
|----------------------------------------------------------------|

|
CRITICAL NEG MOMENT=
1.03 KN-MET AT 2250.MM, LOAD
15|
|
REQD STEEL=
14.MM2, RHO=0.0003, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11748 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


17.72 KNS Vc=
48.17 KNS Vs=
0.00 KNS
Tu=
1.49 KN-MET Tc=
1.3 KN-MET Ts=
2.0 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.65 SQ.CM.
AT END
SUPPORT - Vu=
0.66 KNS Vc=
40.21 KNS Vs=
0.00 KNS
Tu=
1.49 KN-MET Tc=
1.3 KN-MET Ts=
2.0 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1144. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.65 SQ.CM.

___5890J____________________ 2249X 200X 300_____________________5600J____


|
|
||==================================
===================||
| 2No10 H 257.| 0.TO 1051|
|
|
2No10 H|257.1668.TO|2250 |
| 14*12c/c 94 |
|
|
|
|
|
| 14*12c/c 94 | |
|
|2No12 H| 44. 195.TO|2250
|
|
|
|
|
| |
|
=====================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| |
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
|
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN LEVEL

NO. 11752 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
9.00 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
128.MM2, RHO=0.0025, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
2.85 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
40.MM2, RHO=0.0008, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11752 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


13.20 KNS Vc=
36.14 KNS Vs=
0.00 KNS
Tu=
1.43 KN-MET Tc=
0.9 KN-MET Ts=
1.9 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.62 SQ.CM.
AT END
SUPPORT - Vu=
11.44 KNS Vc=
36.14 KNS Vs=
0.00 KNS
Tu=
1.43 KN-MET Tc=
0.9 KN-MET Ts=
1.9 KN-MET LOAD
16
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.62 SQ.CM.

___5565J____________________
420X 200X 300_____________________5927J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11754 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
10.79 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
154.MM2, RHO=0.0030, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6530.3 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
5.27 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
74.MM2, RHO=0.0014, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11754 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


10.80 KNS Vc=
49.15 KNS Vs=
0.00 KNS
Tu=
1.82 KN-MET Tc=
1.4 KN-MET Ts=
2.4 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.79 SQ.CM.
AT END
SUPPORT - Vu=
9.03 KNS Vc=
41.47 KNS Vs=
0.00 KNS
Tu=
1.82 KN-MET Tc=
1.4 KN-MET Ts=
2.4 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.79 SQ.CM.

___5566J____________________
|

419X 200X

300_____________________5908J____
|

||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11755 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
9.63 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
137.MM2, RHO=0.0027, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
1.98 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
28.MM2, RHO=0.0005, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11755 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


23.86 KNS Vc=
42.34 KNS Vs=
Tu=
0.85 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
NO STIRRUPS ARE REQUIRED FOR TORSION.

0.00 KNS
LOAD
14

REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.


PROVIDE 12 MM 2-LEGGED STIRRUPS AT 129. MM C/C FOR

219. MM

AT END
SUPPORT - Vu=
24.51 KNS Vc=
42.34 KNS Vs=
0.00 KNS
Tu=
0.85 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 129. MM C/C FOR 219. MM

___5599J____________________
400X 200X 300_____________________5900J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400 |
|
|
| 3*12c/c129
|
|
3*12c/c129
|
| 2No10 H 43.
0.TO 400 |
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11758 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
12.51 KN-MET AT
0.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
1.62 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
23.MM2, RHO=0.0004, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|

Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11758 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


30.89 KNS Vc=
42.11 KNS Vs=
0.00 KNS
Tu=
0.44 KN-MET Tc=
1.2 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM
AT END
SUPPORT - Vu=
34.16 KNS Vc=
75.63 KNS Vs=
0.00 KNS
Tu=
0.44 KN-MET Tc=
1.2 KN-MET Ts=
0.0 KN-MET LOAD
14
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 128. MM C/C FOR 219. MM

___5600J____________________
400X 200X 300_____________________5906J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 400 |
|
|
| 3*12c/c129
|
|
3*12c/c129
|
| 2No12 H 44.
0.TO 400 |
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11767 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
3.76 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
53.MM2, RHO=0.0010, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|

|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
11.60 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
166.MM2, RHO=0.0032, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11767 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


20.78 KNS Vc=
77.30 KNS Vs=
0.00 KNS
Tu=
1.83 KN-MET Tc=
1.2 KN-MET Ts=
2.4 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.80 SQ.CM.
AT END
SUPPORT - Vu=
21.43 KNS Vc=
41.24 KNS Vs=
0.00 KNS
Tu=
1.83 KN-MET Tc=
1.2 KN-MET Ts=
2.4 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 219. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.80 SQ.CM.

___5900J____________________
400X 200X 300_____________________5901J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 400
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 400
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================

BEAM
LEN -

NO. 11768 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.61 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
93.MM2, RHO=0.0018, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
4 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
24.71 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
273.MM2, RHO=0.0053, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11768 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


23.10 KNS Vc=
41.68 KNS Vs=
0.00 KNS
Tu=
3.22 KN-MET Tc=
1.1 KN-MET Ts=
4.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.40 SQ.CM.
AT END
SUPPORT - Vu=
23.78 KNS Vc=
40.87 KNS Vs=
0.00 KNS
Tu=
3.22 KN-MET Tc=
1.1 KN-MET Ts=
4.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.40 SQ.CM.

___5901J____________________
419X 200X 300_____________________5559J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|

_________
|
|
| oooo
|
| 4#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
| oooo
|
| 4#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
| oooo
|
| 4#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
| oooo
|
| 4#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
| oooo
|
| 4#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

_________
|
|
| oooo
|
| 4#10
|
|
|
| 2#10
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11773 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

400. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
5.21 KN-MET AT
400.MM, LOAD
15|
|
REQD STEEL=
73.MM2, RHO=0.0014, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
400.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
16.31 KN-MET AT
400.MM, LOAD
14|
|
REQD STEEL=
178.MM2, RHO=0.0035, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11773 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


18.22 KNS Vc=
47.94 KNS Vs=
0.00 KNS
Tu=
0.27 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET LOAD
13
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 129. MM C/C FOR 219. MM
AT END
SUPPORT - Vu=
22.58 KNS Vc=
41.25 KNS Vs=
Tu=
0.27 KN-MET Tc=
1.1 KN-MET Ts=
0.0 KN-MET
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

0.00 KNS
LOAD
13

PROVIDE 12 MM 2-LEGGED STIRRUPS AT 129. MM

C/C FOR

219. MM

___5906J____________________
400X 200X 300_____________________5907J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 400 |
|
|
| 3*12c/c129
|
|
3*12c/c129
|
| 2No10 H 43.
0.TO 400 |
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11774 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.43 KN-MET AT
420.MM, LOAD
15|
|
REQD STEEL=
105.MM2, RHO=0.0020, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
254.
2 - 16MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
35.22 KN-MET AT
420.MM, LOAD
14|
|
REQD STEEL=
402.MM2, RHO=0.0078, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|
|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11774 D E S I G N

14071.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


41.47 KNS Vc=
41.52 KNS Vs=
13.77 KNS
Tu=
1.83 KN-MET Tc=
1.1 KN-MET Ts=
2.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.80 SQ.CM.
AT END
SUPPORT - Vu=
44.89 KNS Vc=
40.90 KNS Vs=
18.95 KNS
Tu=
1.83 KN-MET Tc=
1.1 KN-MET Ts=
2.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.80 SQ.CM.

___5907J____________________
419X 200X 300_____________________5560J____
|
|
||=========================================================================||
| 2No16 H 254.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#16
| | 2#16
| | 2#16
| | 2#16
| | 2#16
|
| 2#16
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11775 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
13.59 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|

|
CRITICAL NEG MOMENT=
12.61 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11775 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


5.59 KNS Vc=
41.16 KNS Vs=
0.00 KNS
Tu=
2.70 KN-MET Tc=
1.1 KN-MET Ts=
3.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.18 SQ.CM.
AT END
SUPPORT - Vu=
7.36 KNS Vc=
44.61 KNS Vs=
0.00 KNS
Tu=
2.70 KN-MET Tc=
1.1 KN-MET Ts=
3.6 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.18 SQ.CM.

___5908J____________________
420X 200X 300_____________________5917J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN LEVEL

NO. 11776 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
5.41 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
76.MM2, RHO=0.0015, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
3.02 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
42.MM2, RHO=0.0008, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11776 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


11.67 KNS Vc=
41.46 KNS Vs=
0.00 KNS
Tu=
2.23 KN-MET Tc=
1.1 KN-MET Ts=
3.0 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.97 SQ.CM.
AT END
SUPPORT - Vu=
12.57 KNS Vc=
41.46 KNS Vs=
0.00 KNS
Tu=
2.23 KN-MET Tc=
1.1 KN-MET Ts=
3.0 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.97 SQ.CM.

___5909J____________________
420X 200X 300_____________________5918J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11786 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
16.08 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
175.MM2, RHO=0.0034, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
22.44 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
247.MM2, RHO=0.0048, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11786 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


9.50 KNS Vc=
48.21 KNS Vs=
0.00 KNS
Tu=
4.77 KN-MET Tc=
1.1 KN-MET Ts=
6.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.08 SQ.CM.
AT END
SUPPORT - Vu=
11.31 KNS Vc=
42.61 KNS Vs=
0.00 KNS
Tu=
4.77 KN-MET Tc=
1.1 KN-MET Ts=
6.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.08 SQ.CM.

___5917J____________________
|

430X 200X

300_____________________5560J____
|

||=========================================================================||
| 4No10 H 257.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11787 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
3.09 KN-MET AT
108.MM, LOAD
17|
|
REQD STEEL=
43.MM2, RHO=0.0008, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
14.39 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11787 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


17.46 KNS Vc=
74.27 KNS Vs=
Tu=
4.39 KN-MET Tc=
1.1 KN-MET Ts=
5.9 KN-MET
STIRRUPS ARE REQUIRED FOR TORSION.

0.00 KNS
LOAD
13

REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.


PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =

1.91 SQ.CM.

AT END
SUPPORT - Vu=
18.39 KNS Vc=
40.73 KNS Vs=
0.00 KNS
Tu=
4.39 KN-MET Tc=
1.1 KN-MET Ts=
5.9 KN-MET LOAD
13
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.91 SQ.CM.

___5918J____________________
430X 200X 300_____________________5532J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11798 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
13.60 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
256.
2 - 12MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
11.41 KN-MET AT
420.MM, LOAD
17|
|
REQD STEEL=
164.MM2, RHO=0.0032, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|

|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11798 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


5.79 KNS Vc=
41.27 KNS Vs=
0.00 KNS
Tu=
2.46 KN-MET Tc=
1.1 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.07 SQ.CM.
AT END
SUPPORT - Vu=
7.56 KNS Vc=
46.59 KNS Vs=
0.00 KNS
Tu=
2.46 KN-MET Tc=
1.1 KN-MET Ts=
3.3 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.07 SQ.CM.

___5927J____________________
419X 200X 300_____________________5931J____
|
|
||=========================================================================||
| 2No12 H 256.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No12 H 44.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11803 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

44.

2 - 12MM

0.

430.

YES

YES

|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
18.19 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
199.MM2, RHO=0.0039, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8871.6 cm^4

2
257.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
22.35 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
246.MM2, RHO=0.0048, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11803 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


9.16 KNS Vc=
49.17 KNS Vs=
0.00 KNS
Tu=
4.02 KN-MET Tc=
1.1 KN-MET Ts=
5.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.75 SQ.CM.
AT END
SUPPORT - Vu=
10.96 KNS Vc=
42.74 KNS Vs=
0.00 KNS
Tu=
4.02 KN-MET Tc=
1.1 KN-MET Ts=
5.4 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
1.75 SQ.CM.

___5931J____________________
430X 200X 300_____________________5559J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11854 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.39 KN-MET AT
420.MM, LOAD
16|
|
REQD STEEL=
105.MM2, RHO=0.0020, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
406.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
1.01 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
14.MM2, RHO=0.0003, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11854 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


7.97 KNS Vc=
41.92 KNS Vs=
Tu=
0.16 KN-MET Tc=
1.2 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.
AT END
SUPPORT - Vu=
7.06 KNS Vc=
40.89 KNS Vs=
Tu=
0.16 KN-MET Tc=
1.2 KN-MET Ts=
0.0 KN-MET
STIRRUPS ARE NOT REQUIRED.

0.00 KNS
LOAD
13
0.00 KNS
LOAD
13

___5943J____________________
420X 200X 300_____________________5575J____
|
|
||======================================================================== |
| 2No10 H 257.
0.TO 406
|
|
|
| 2No10 H 43.
0.TO 420
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
|
|

|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
|
| 2#10
|
|
oo
|
|
|
|_________|

|
|
| 2#10
|
|
oo
|
|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11859 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

420. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
6.53 KN-MET AT
350.MM, LOAD
16|
|
REQD STEEL=
92.MM2, RHO=0.0018, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
420.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
6.14 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
87.MM2, RHO=0.0017, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11859 D E S I G N

6585.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


6.53 KNS Vc=
41.21 KNS Vs=
0.00 KNS
Tu=
2.09 KN-MET Tc=
1.1 KN-MET Ts=
2.8 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.91 SQ.CM.
AT END
SUPPORT - Vu=
5.85 KNS Vc=
41.21 KNS Vs=
0.00 KNS
Tu=
2.09 KN-MET Tc=
1.1 KN-MET Ts=
2.8 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 229. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.91 SQ.CM.

___5948J____________________
419X 200X 300_____________________5943J____
|
|
||=========================================================================||
| 2No10 H 257.
0.TO 420
|
|
| |
| 4*12c/c 94
|
|
|
4*12c/c 94 | |
| 2No10 H 43.
0.TO 420
|
|
| |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11879 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

1470. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
1470.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
7.68 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
109.MM2, RHO=0.0021, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
256.
2 - 12MM
191.
1470.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
16.92 KN-MET AT 1470.MM, LOAD
16|
|
REQD STEEL=
185.MM2, RHO=0.0036, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11879 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


3.08 KNS Vc=
40.58 KNS Vs=
0.00 KNS
Tu=
1.68 KN-MET Tc=
1.1 KN-MET Ts=
2.2 KN-MET LOAD
15
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 754. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.73 SQ.CM.
AT END
SUPPORT - Vu=
12.29 KNS Vc=
41.42 KNS Vs=
0.00 KNS
Tu=
1.68 KN-MET Tc=
1.1 KN-MET Ts=
2.2 KN-MET LOAD
15
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 754. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.73 SQ.CM.

___5575J____________________ 1470X 200X 300_____________________5536J____


|
|
|
==================================================================||
|
2No12 H|256.|191.TO 1470
|
|
|
|
|
|
|
|
|
| 10*12c/c 94
|
|
|
|
|
|
|
|
|
10*12c/c 94|
|
| 2No10 H 43.
0.TO 1470 |
|
|
|
|
|
|
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN -

NO. 11893 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
24.65 KN-MET AT
0.MM, LOAD
16|
|
REQD STEEL=
273.MM2, RHO=0.0053, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

11687.7 cm^4

2
254.
2 - 16MM
0.
430.
YES YES
|----------------------------------------------------------------|

|
CRITICAL NEG MOMENT=
31.40 KN-MET AT
0.MM, LOAD
17|
|
REQD STEEL=
358.MM2, RHO=0.0070, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
41./ 109. MMS
|
|
REQD. DEVELOPMENT LENGTH =
481. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11893 D E S I G N

13828.1 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


13.35 KNS Vc=
43.67 KNS Vs=
0.00 KNS
Tu=
6.49 KN-MET Tc=
1.1 KN-MET Ts=
8.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.83 SQ.CM.
AT END
SUPPORT - Vu=
11.55 KNS Vc=
57.33 KNS Vs=
0.00 KNS
Tu=
6.49 KN-MET Tc=
1.1 KN-MET Ts=
8.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.83 SQ.CM.

___5557J____________________
430X 200X 300_____________________5805J____
|
|
||=========================================================================||
| 2No16 H 254.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 4No10 H 43.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
| 2#16
| | 2#16
| | 2#16
| | 2#16
| | 2#16
|
| 2#16
|
|
| |
| |
| |
| |
|
|
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

=====================================================================
BEAM
LEN LEVEL

NO. 11895 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

430. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
44.
2 - 12MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
20.23 KN-MET AT
430.MM, LOAD
17|
|
REQD STEEL=
221.MM2, RHO=0.0043, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

8946.9 cm^4

2
257.
4 - 10MM
0.
430.
YES YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
25.47 KN-MET AT
430.MM, LOAD
16|
|
REQD STEEL=
282.MM2, RHO=0.0055, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./
38. MMS
|
|
REQD. DEVELOPMENT LENGTH =
393. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11895 D E S I G N

11687.7 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


11.12 KNS Vc=
42.22 KNS Vs=
0.00 KNS
Tu=
5.80 KN-MET Tc=
1.1 KN-MET Ts=
7.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.53 SQ.CM.
AT END
SUPPORT - Vu=
12.92 KNS Vc=
42.22 KNS Vs=
0.00 KNS
Tu=
5.80 KN-MET Tc=
1.1 KN-MET Ts=
7.7 KN-MET LOAD
14
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 234. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
2.53 SQ.CM.

___5856J____________________
430X 200X 300_____________________5584J____
|
|
||=========================================================================||
| 4No10 H 257.
0.TO 430
|
|
|
|
| 4*12c/c 94
|
|
|
4*12c/c 94
|
| 2No12 H 44.
0.TO 430
|
|
|
|
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
| oooo
| | oooo
| | oooo
| | oooo
| | oooo
|
| oooo
|
| 4#10
| | 4#10
| | 4#10
| | 4#10
| | 4#10
|
| 4#10
|
|
| |
| |
| |
| |
|
|
|
| 2#12
| | 2#12
| | 2#12
| | 2#12
| | 2#12
|
| 2#12
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

|
|
|_________|

=====================================================================
BEAM
LEN -

NO. 11897 DESIGN RESULTS - FLEXURE PER CODE ACI 318-08

3470. MM

FY -

412.

FC -

25.

MPA, SIZE -

200. X

300. MMS

LEVEL

HEIGHT
BAR INFO
FROM
TO
ANCHOR
(MM)
(MM)
(MM)
STA END
_____________________________________________________________________

1
43.
2 - 10MM
0.
3470.
YES YES
|----------------------------------------------------------------|
|
CRITICAL POS MOMENT=
4.55 KN-MET AT
867.MM, LOAD
14|
|
REQD STEEL=
64.MM2, RHO=0.0012, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

2
257.
2 - 10MM
0.
1168.
YES NO
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
8.47 KN-MET AT
0.MM, LOAD
15|
|
REQD STEEL=
120.MM2, RHO=0.0023, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
35./ 115. MMS
|
|
REQD. DEVELOPMENT LENGTH =
305. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

6585.1 cm^4

3
256.
2 - 12MM
1808.
3470.
NO
YES
|----------------------------------------------------------------|
|
CRITICAL NEG MOMENT=
12.20 KN-MET AT 3470.MM, LOAD
14|
|
REQD STEEL=
172.MM2, RHO=0.0033, RHOMX=0.0191 RHOMN=0.0033 |
|
MAX/MIN/ACTUAL BAR SPACING=
288./
37./ 113. MMS
|
|
REQD. DEVELOPMENT LENGTH =
361. MMS
|
|----------------------------------------------------------------|
Cracked Moment of Inertia Iz at above location =

B E A M

N O. 11897 D E S I G N

8871.6 cm^4

R E S U L T S - SHEAR

AT START SUPPORT - Vu=


5.47 KNS Vc=
76.64 KNS Vs=
0.00 KNS
Tu=
1.72 KN-MET Tc=
1.2 KN-MET Ts=
2.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1754. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.75 SQ.CM.

AT END
SUPPORT - Vu=
10.21 KNS Vc=
40.73 KNS Vs=
0.00 KNS
Tu=
1.72 KN-MET Tc=
1.2 KN-MET Ts=
2.3 KN-MET LOAD
17
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 94. MM C/C FOR 1754. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE =
0.75 SQ.CM.

___5535J____________________ 3469X 200X 300_____________________5953J____


|
|
||========================
====================================||
| 2No10 H 257.| 0.TO 1168
2No12 H|256.1808.TO|3470 | | | | |
| 20*12c/c 94 | | | |
| | | | | | | 20*12c/c 94 | |
| 2No10 H 43.| 0.TO 3470
| | | | | | | | | | | | |
||=========================================================================||
|
|
|___________________________________________________________________________|
_________
_________
_________
_________
_________
_________
|
| |
| |
| |
| |
|
|
|
|
oo
| |
oo
| |
| |
oo
| |
oo
|
|
oo
|
| 2#10
| | 2#10
| |
| | 2#12
| | 2#12
|
| 2#12
|
|
| |
| |
| |
| |
|
|
|
| 2#10
| | 2#10
| | 2#10
| | 2#10
| | 2#10
|
| 2#10
|
|
oo
| |
oo
| |
oo
| |
oo
| |
oo
|
|
oo
|
|
| |
| |
| |
| |
|
|
|
|_________| |_________| |_________| |_________| |_________|
|_________|

********************END OF BEAM DESIGN**************************

569.
570.
571.
572.

DESIGN COLUMN 10982 TO 10985 10990 10991 10998 10999 11006 11007 11014 11015 11022 TO 11025 11030 TO 11033 11038 11039 11046 TO 11049 11287 11288 11440 11441 11480 11481 11578 11579 11745 11746 11880 11881 11883 11885 TO 11889 11891 11892 11896 11898 TO 11906

====================================================================
COLUMN

NO. 10982

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED =
856.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------8 - 12 MM
1.131
16
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 192.00 MM

STA

0.900

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2021.61
1617.28
775.07
129.03
166.5
M0
P-tens.
Des.Pn
Des.Mn
e/h

-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2021.61
1617.28
698.56
59.58
85.3
M0
P-tens.
Des.Pn
Des.Mn
e/h
29.68
-372.77
-181.87
10.27
-0.03689
--------------------------------------------------------

====================================================================
COLUMN

NO. 10983

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
442.40
2.81
0.00415
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
442.40
0.67
0.00099
--------------------------------------------------------

====================================================================
COLUMN

NO. 10984

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
----------------------------------------------------------

4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
383.64
14.12
0.02406
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
383.64
7.96
0.01356
--------------------------------------------------------

====================================================================
COLUMN

NO. 10985

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
447.95
17.28
0.02521
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
447.95
1.25
0.00183
--------------------------------------------------------

====================================================================

COLUMN

NO. 10990

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED =
968.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 20 MM
1.571
16
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

STA

0.900

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
753.72
166.11
220.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
87.25
-517.74
-113.98
34.77
-0.19936
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
663.36
72.22
108.9
M0
P-tens.
Des.Pn
Des.Mn
e/h
38.68
-517.74
-113.98
10.29
-0.05902
--------------------------------------------------------

====================================================================
COLUMN

NO. 10991

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
360.98
4.61
0.00836
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)

-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
360.98
0.16
0.00028
--------------------------------------------------------

====================================================================
COLUMN

NO. 10998

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
235.65
0.47
0.00131
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
235.65
2.17
0.00603
--------------------------------------------------------

====================================================================
COLUMN

NO. 10999

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
275.77
5.78
0.01369
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
275.77
0.20
0.00048
--------------------------------------------------------

====================================================================
COLUMN

NO. 11006

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
176.22
0.62
0.00229
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
176.22
2.21
0.00821
--------------------------------------------------------

====================================================================
COLUMN

NO. 11007

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
191.31
5.60
0.01914
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
191.31
0.15
0.00052
--------------------------------------------------------

====================================================================
COLUMN

NO. 11014

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
116.97
0.07
0.00039
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
--------------------------------------------------------

P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
116.97
1.55
0.00866
--------------------------------------------------------

====================================================================
COLUMN

NO. 11015

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
105.73
7.34
0.04540
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
105.73
0.73
0.00448
--------------------------------------------------------

====================================================================
COLUMN

NO. 11022

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED =
912.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 20 MM
1.571
16
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)

0.900

-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
753.72
166.11
220.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
87.25
-517.74
-181.43
13.59
-0.37453
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
663.36
72.22
108.9
M0
P-tens.
Des.Pn
Des.Mn
e/h
38.68
-517.74
-181.43
11.44
-0.31533
--------------------------------------------------------

====================================================================
COLUMN

NO. 11023

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
421.31
4.91
0.05828
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
421.31
3.73
0.04426
--------------------------------------------------------

====================================================================
COLUMN

NO. 11024

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.

AREA OF STEEL REQUIRED =

800.0

SQ. MM

BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
390.66
12.81
0.16396
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
390.66
6.58
0.08417
--------------------------------------------------------

====================================================================
COLUMN

NO. 11025

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED = 1080.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 20 MM
1.571
17
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
753.72
166.11
220.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
87.25
-517.74
33.47
0.19
0.02826
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
663.36
72.22
108.9
M0
P-tens.
Des.Pn
Des.Mn
e/h
38.68
-517.74
33.47
36.24
5.41368

--------------------------------------------------------

====================================================================
COLUMN

NO. 11030

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED = 1696.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 25 MM
2.454
16
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.900

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2435.72
1948.58
741.10
210.89
284.6
M0
P-tens.
Des.Pn
Des.Mn
e/h
133.52
-808.95
-215.08
17.41
-0.06227
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2435.72
1948.58
617.50
86.80
140.6
M0
P-tens.
Des.Pn
Des.Mn
e/h
56.41
-808.95
-215.08
32.34
-0.11567
--------------------------------------------------------

====================================================================
COLUMN

NO. 11031

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED = 1248.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------8 - 16 MM
2.011
17
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.900

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2296.88
1837.50
769.54
163.82
212.9
M0
P-tens.
Des.Pn
Des.Mn
e/h

-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2296.88
1837.50
679.39
72.61
106.9
M0
P-tens.
Des.Pn
Des.Mn
e/h
48.67
-662.71
-134.75
27.81
-0.15876
--------------------------------------------------------

====================================================================
COLUMN

NO. 11032

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
424.12
7.48
0.01357
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
424.12
3.20
0.00580
--------------------------------------------------------

====================================================================
COLUMN

NO. 11033

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED = 1024.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 20 MM

1.571

17

END

0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)


TIE BAR NUMBER
12 SPACING 200.00 MM
COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
753.72
166.11
220.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
87.25
-517.74
28.73
15.66
0.41933
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
663.36
72.22
108.9
M0
P-tens.
Des.Pn
Des.Mn
e/h
38.68
-517.74
28.73
29.76
0.79674
--------------------------------------------------------

====================================================================
COLUMN

NO. 11038

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
42.79
1.49
0.02268
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
42.79
1.77
0.02691
--------------------------------------------------------

====================================================================

COLUMN

NO. 11039

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
39.54
1.16
0.01910
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
39.54
1.41
0.02322
--------------------------------------------------------

====================================================================
COLUMN

NO. 11046

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
29.64
11.99
0.44927
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)

-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
29.64
6.28
0.23551
--------------------------------------------------------

====================================================================
COLUMN

NO. 11047

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
27.61
10.00
0.40254
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
27.61
4.77
0.19192
--------------------------------------------------------

====================================================================
COLUMN

NO. 11048

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
29.10
12.54
0.47880
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
29.10
6.02
0.22975
--------------------------------------------------------

====================================================================
COLUMN

NO. 11049

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
31.03
14.45
0.51751
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
31.03
7.38
0.26433
--------------------------------------------------------

====================================================================
COLUMN

NO. 11287

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED = 1136.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 20 MM
1.571
16
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.900

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
753.72
166.11
220.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
87.25
-517.74
-186.23
37.09
-0.13019
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
663.36
72.22
108.9
M0
P-tens.
Des.Pn
Des.Mn
e/h
38.68
-517.74
-186.23
7.98
-0.02800
--------------------------------------------------------

====================================================================
COLUMN

NO. 11288

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED =
856.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------8 - 12 MM
1.131
17
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 192.00 MM

END

0.900

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2021.61
1617.28
775.07
129.03
166.5
M0
P-tens.
Des.Pn
Des.Mn
e/h
64.41
-372.77
-111.13
27.33
-0.16075
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2021.61
1617.28
698.56
59.58
85.3

M0
P-tens.
Des.Pn
Des.Mn
e/h
29.68
-372.77
-111.13
9.38
-0.05519
--------------------------------------------------------

====================================================================
COLUMN

NO. 11440

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED =
912.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 20 MM
1.571
16
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.900

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
753.72
166.11
220.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
87.25
-517.74
-116.94
32.43
-0.18123
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2159.24
1727.39
663.36
72.22
108.9
M0
P-tens.
Des.Pn
Des.Mn
e/h
38.68
-517.74
-116.94
7.50
-0.04194
--------------------------------------------------------

====================================================================
COLUMN

NO. 11441

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)

1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
325.61
6.09
0.01223
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
325.61
8.31
0.01668
--------------------------------------------------------

====================================================================
COLUMN

NO. 11480

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
240.30
5.59
0.01520
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
240.30
8.41
0.02289
--------------------------------------------------------

====================================================================
COLUMN

NO. 11481

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM

BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
216.72
8.49
0.02560
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
216.72
5.20
0.01567
--------------------------------------------------------

====================================================================
COLUMN

NO. 11578

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
155.40
6.34
0.02667
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
155.40
8.68
0.03650
--------------------------------------------------------

====================================================================
COLUMN

NO. 11579

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
157.47
7.60
0.03154
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
157.47
5.43
0.02254
--------------------------------------------------------

====================================================================
COLUMN

NO. 11745

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h

57.43
-331.35
69.78
4.49
0.04201
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
69.78
7.07
0.06621
--------------------------------------------------------

====================================================================
COLUMN

NO. 11746

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
99.58
4.03
0.02645
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
99.58
3.21
0.02105
--------------------------------------------------------

====================================================================
COLUMN

NO. 11880

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
----------------------------------------------------------

4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
61.46
1.65
0.01751
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
61.46
0.97
0.01032
--------------------------------------------------------

====================================================================
COLUMN

NO. 11881

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
74.21
10.13
0.08920
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
74.21
0.84
0.00740
--------------------------------------------------------

====================================================================
COLUMN

NO. 11883

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
132.43
0.20
0.00098
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
132.43
0.27
0.00135
--------------------------------------------------------

====================================================================
COLUMN

NO. 11885

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
196.30
0.07
0.00024
--------------------------------------------------------

COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
196.30
0.05
0.00016
--------------------------------------------------------

====================================================================
COLUMN

NO. 11886

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
304.50
0.31
0.00067
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
304.50
0.15
0.00033
--------------------------------------------------------

====================================================================
COLUMN

NO. 11887

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM

1.005

13

END

0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)


TIE BAR NUMBER
12 SPACING 200.00 MM
COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
260.61
0.35
0.00088
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
260.61
0.09
0.00023
--------------------------------------------------------

====================================================================
COLUMN

NO. 11888

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


AREA OF STEEL REQUIRED =
856.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------8 - 12 MM
1.131
17
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 192.00 MM

STA

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2021.61
1617.28
775.07
129.03
166.5
M0
P-tens.
Des.Pn
Des.Mn
e/h
64.41
-372.77
57.35
13.78
0.15702
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
2021.61
1617.28
698.56
59.58
85.3
M0
P-tens.
Des.Pn
Des.Mn
e/h
29.68
-372.77
57.35
28.20
0.32132
--------------------------------------------------------

====================================================================
COLUMN

NO. 11889

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
325.61
0.55
0.00110
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
325.61
0.43
0.00086
--------------------------------------------------------

====================================================================
COLUMN

NO. 11891

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
142.19
1.15
0.00529
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)

-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
142.19
0.08
0.00035
--------------------------------------------------------

====================================================================
COLUMN

NO. 11892

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
223.61
0.05
0.00013
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
223.61
0.07
0.00019
--------------------------------------------------------

====================================================================
COLUMN

NO. 11896

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
49.87
5.22
0.06801
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
49.87
0.06
0.00072
--------------------------------------------------------

====================================================================
COLUMN

NO. 11898

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
319.40
12.39
0.02536
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
319.40
6.11
0.01251
--------------------------------------------------------

====================================================================
COLUMN

NO. 11899

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
378.16
17.05
0.02948
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
378.16
2.62
0.00452
--------------------------------------------------------

====================================================================
COLUMN

NO. 11900

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
254.40
13.52
0.03472
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)

1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
254.40
5.45
0.01401
--------------------------------------------------------

====================================================================
COLUMN

NO. 11901

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
298.28
19.34
0.04239
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
298.28
3.85
0.00843
--------------------------------------------------------

====================================================================
COLUMN

NO. 11902

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)

0.650

-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
190.08
13.59
0.04673
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
190.08
5.25
0.01804
--------------------------------------------------------

====================================================================
COLUMN

NO. 11903

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
217.40
18.43
0.05541
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
217.40
3.86
0.01159
--------------------------------------------------------

====================================================================
COLUMN

NO. 11904

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.

AREA OF STEEL REQUIRED =

800.0

SQ. MM

BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
126.22
12.74
0.06596
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
126.22
5.62
0.02909
--------------------------------------------------------

====================================================================
COLUMN

NO. 11905

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
135.98
21.67
0.10415
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h

26.42
-331.35
135.98
4.22
0.02026
--------------------------------------------------------

====================================================================
COLUMN

NO. 11906

DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 412.0 FC - 24.5 MPA, RECT SIZE - 200.0 X 400.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED =
800.0 SQ. MM
BAR CONFIGURATION
REINF PCT.
LOAD
LOCATION
PHI
---------------------------------------------------------4 - 16 MM
1.005
13
(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER
12 SPACING 200.00 MM

END

0.650

COLUMN INTERACTION: MOMENT ABOUT Z -AXIS (KN-MET)


-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
762.64
136.85
179.4
M0
P-tens.
Des.Pn
Des.Mn
e/h
57.43
-331.35
55.21
9.69
0.11395
-------------------------------------------------------COLUMN INTERACTION: MOMENT ABOUT Y -AXIS (KN-MET)
-------------------------------------------------------P0
Pn max
P-bal.
M-bal.
e-bal. (MM)
1982.29
1585.83
688.45
61.96
90.0
M0
P-tens.
Des.Pn
Des.Mn
e/h
26.42
-331.35
55.21
3.17
0.03733
--------------------------------------------------------

********************END OF COLUMN DESIGN RESULTS********************

573. DESIGN ELEMENT ALL

ELEMENT DESIGN SUMMARY


---------------------ELEMENT

11183
11183
11183
11183
11183

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :

LONG. REINF
(SQ.MM/MM)

MOM-X /LOAD
(KN-MM/MM)

TRANS. REINF
(SQ.MM/MM)

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.98 /
17
0.200

MOM-Y /LOAD
(KN-MM/MM)
25.000 MM
required.
required.
required.
required.
1.21 /

15

11184
11184
11184
11184
11184

11185
11185
11185
11185
11185

11186
11186
11186
11186
11186

11187
11187
11187
11187
11187

11188
11188
11188
11188
11188

11189
11189
11189
11189
11189

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.53 /
17
0.200
0.200
0.65 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.31 /
17
0.200
0.200
0.55 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.28 /
17
0.200
0.200
0.52 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.42 /
17
0.200
0.200
0.56 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.75 /
17
0.200
0.200
0.63 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.92 /
16
0.200

FY:
COVER
11190 TOP :
11190 BOTT:

25.000 MM
required.
required.
required.
required.
0.16 /
0.86 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
0.92 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
0.90 /

15
13

25.000 MM
required.
required.
required.
required.
0.21 /
0.81 /

14
15

25.000 MM
required.
required.
required.
required.
1.26 /
0.30 /

14
15

25.000 MM
required.
required.
required.
required.
0.89 /
0.29 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.

15
14

11190 TOP : Transverse direction


11190 BOTT: Transverse direction
11190 TOP :
0.200
0.00
BOTT:
0.200
1.32

11191
11191
11191
11191
11191

11192
11192
11192
11192
11192

11193
11193
11193
11193
11193

11194
11194
11194
11194
11194

11195
11195
11195
11195
11195

11196
11196
11196
11196
11196

- Only minimum steel required.


- Only minimum steel required.
/
17
0.200
0.00 /
/
13
0.200
1.12 /

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
1.59 /
13
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
1.58 /
13
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
1.29 /
13
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.80 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.96 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
1.36 /
13
0.200

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
1.40 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.37 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.05 /

15
15

25.000 MM
required.
required.
required.
required.
0.98 /
0.18 /

14
15

25.000 MM
required.
required.
required.
required.
0.85 /
0.32 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
1.16 /

15
14

11197
11197
11197
11197
11197

11198
11198
11198
11198
11198

11199
11199
11199
11199
11199

11200
11200
11200
11200
11200

11201
11201
11201
11201
11201

11202
11202
11202
11202
11202

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
1.62 /
13
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
1.59 /
13
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
1.29 /
13
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.78 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.91 /
16
0.200
0.200
0.96 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.48 /
16
0.200
0.200
0.74 /
17
0.200

FY:
COVER
11203 TOP :
11203 BOTT:
11203 TOP :

25.000 MM
required.
required.
required.
required.
0.00 /
1.42 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.37 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.05 /

15
15

25.000 MM
required.
required.
required.
required.
1.01 /
0.16 /

14
15

25.000 MM
required.
required.
required.
required.
1.14 /
0.49 /

15
14

25.000 MM
required.
required.
required.
required.
0.13 /
0.95 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.

15
14

11203 BOTT: Transverse direction


- Only minimum steel required.
11203 TOP :
0.200
0.29 /
16
0.200
0.00 /
BOTT:
0.200
0.59 /
17
0.200
0.95 /

11204
11204
11204
11204
11204

11205
11205
11205
11205
11205

11206
11206
11206
11206
11206

11286
11286
11286
11286

11291
11291
11291
11291

11292
11292
11292
11292
11292

15
13

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.28 /
16
0.200
0.200
0.53 /
17
0.200

25.000 MM

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.46 /
16
0.200
0.200
0.52 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.82 /
16
0.200
0.200
0.56 /
17
0.200

required.
required.
required.
required.
1.39 /
0.25 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.88 /
16
0.319
6.24 /
0.200
0.00 /
17
0.200
0.46 /

16
17

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.92 /
16
0.253
5.02 /
0.200
0.00 /
17
0.200
0.00 /

14
17

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.47 /
16
0.200
0.200
1.52 /
17
0.200

14
17

required.
required.
required.
required.
0.00 /
0.88 /

15
13

25.000 MM
required.
required.
required.
required.
0.30 /
0.80 /

14
15

25.000 MM

25.000 MM
required.
required.
required.
required.
2.73 /
0.00 /

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
25.000 MM
COVER (BOTTOM):
25.000 MM TH:
100.000 MM
11293 TOP : Longitudinal direction - Only minimum steel required.

11293
11293
11293
11293

11294
11294
11294
11294
11294

11295
11295
11295
11295

11296
11296
11296
11296
11296

11297
11297
11297
11297
11297

11298
11298
11298
11298
11298

11299
11299
11299
11299
11299

BOTT: Longitudinal direction


TOP : Transverse direction
BOTT: Transverse direction
TOP :
0.200
0.29
BOTT:
0.200
0.00

- Only minimum steel required.


- Only minimum steel required.
- Only minimum steel required.
/
13
0.200
3.66 /
/
17
0.200
0.00 /

17
17

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.29 /
16
0.200
0.200
1.11 /
17
0.200

25.000 MM
required.
required.
required.
required.
2.76 /
0.00 /

13
17

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
2.64 /
16
0.203
4.06 /
0.200
1.15 /
17
0.200
0.00 /

16
17

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.10 /
16
0.200
0.200
0.03 /
17
0.200

16
13

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.61 /
16
0.200
0.200
0.77 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.04 /
16
0.200
0.200
0.07 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.15 /
16
0.200
0.200
0.11 /
17
0.200

25.000 MM
required.
required.
required.
required.
0.00 /
1.32 /
25.000 MM
required.
required.
required.
required.
0.00 /
1.29 /

16
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.28 /

16
13

25.000 MM
required.
required.
required.
required.
0.00 /
3.48 /

16
14

11300
11300
11300
11300
11300

11301
11301
11301
11301
11301

11302
11302
11302
11302

11303
11303
11303
11303

11304
11304
11304
11304
11304

11305
11305
11305
11305
11305

11306
11306
11306
11306
11306

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.04 /
16
0.200
0.200
0.27 /
17
0.200

25.000 MM

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.17 /
16
0.200
0.200
0.08 /
17
0.200

required.
required.
required.
required.
0.00 /
3.46 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.26 /
17
0.200
0.00 /
0.200
0.22 /
16
0.212
4.24 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.13 /
15
0.200
0.00 /
0.200
0.47 /
14
0.206
4.13 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.14 /
17
0.200
0.200
0.12 /
16
0.200

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
3.10 /
16
0.200
0.200
3.02 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.71 /
15
0.200

required.
required.
required.
required.
0.00 /
3.39 /

16
14

25.000 MM

25.000 MM
required.
required.
required.
required.
0.00 /
3.96 /
25.000 MM
required.
required.
required.
required.
3.36 /
3.76 /

15
14

25.000 MM
required.
required.
required.
required.
2.93 /

15

BOTT:

11307
11307
11307
11307
11307

11308
11308
11308
11308
11308

11309
11309
11309
11309
11309

0.200

0.75 /

14

0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.89 /
16
0.200
0.200
0.23 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.65 /
16
0.200
0.200
0.00 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.46 /
17
0.200
0.200
1.63 /
16
0.200

3.11 /

14

25.000 MM
required.
required.
required.
required.
2.83 /
2.07 /

15
14

25.000 MM
required.
required.
required.
required.
1.89 /
1.32 /

16
17

25.000 MM
required.
required.
required.
required.
2.89 /
1.03 /

15
14

FY:
COVER
11310 TOP :
11310 BOTT:
11310 TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.250
6.14 /
17
0.200
3.30 /
0.326
7.91 /
16
0.200
1.12 /

15
14

FY:
COVER
TOP :
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
3.09 /
15
0.200
3.07 /
0.273
6.67 /
14
0.200
1.79 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
3.71 /
16
0.200
0.200
4.32 /
17
0.200

17
16

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel

11311
11311
11311
11311

11312
11312
11312
11312
11312

11313
11313
11313
11313

25.000 MM
required.
required.
required.
required.
3.37 /
2.39 /
25.000 MM
required.
required.
required.
required.

11313 TOP :
BOTT:

11314
11314
11314
11314
11314

11315
11315
11315
11315
11315

11316
11316
11316
11316
11316

11317
11317
11317
11317
11317

11318
11318
11318
11318
11318

11319
11319
11319
11319
11319

0.200
0.200

1.23 /
1.19 /

16
17

0.200
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.20 /
16
0.200
0.200
1.75 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.21 /
17
0.200
0.200
1.44 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.36 /
17
0.200
0.200
2.64 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
3.33 /
17
0.200
0.200
4.80 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.73 /
15
0.200
0.200
2.48 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.27 /
16
0.200
0.200
2.46 /
17
0.200

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
COVER (BOTTOM):
25.000 MM TH:
100.000 MM

2.50 /
1.22 /

15
14

25.000 MM
required.
required.
required.
required.
1.41 /
1.00 /

15
14

25.000 MM
required.
required.
required.
required.
2.41 /
1.50 /

14
15

25.000 MM
required.
required.
required.
required.
1.78 /
0.86 /

14
15

25.000 MM
required.
required.
required.
required.
1.42 /
0.50 /

14
15

25.000 MM
required.
required.
required.
required.
1.46 /
0.49 /

14
15

25.000 MM
required.
required.
required.
required.
1.36 /
0.47 /
25.000 MM

14
15

11320
11320
11320
11320
11320

11321
11321
11321
11321
11321

11322
11322
11322
11322

11323
11323
11323
11323

11324
11324
11324
11324

11325
11325
11325
11325

11326
11326
11326
11326

TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
1.97
0.200
2.39

/
/

Only
Only
Only
Only
16
17

minimum steel
minimum steel
minimum steel
minimum steel
0.200
0.200

required.
required.
required.
required.
1.52 /
0.76 /

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
3.34 /
16
0.200
0.200
2.87 /
17
0.200

required.
required.
required.
required.
2.20 /
1.12 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
4.65 /
17
0.311
6.10 /
0.200
3.33 /
16
0.200
3.45 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
2.99 /
17
0.242
4.81 /
0.200
2.97 /
16
0.200
2.78 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
1.43 /
17
0.211
4.21 /
0.200
2.29 /
16
0.200
2.53 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.00 /
17
0.202
4.05 /
0.200
1.11 /
14
0.200
2.49 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.67 /
16
0.200
4.01 /
0.200
1.68 /
17
0.200
2.48 /

14
15

14
15

25.000 MM

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
25.000 MM
COVER (BOTTOM):
25.000 MM TH:
100.000 MM
11327 TOP : Longitudinal direction - Only minimum steel required.

11327 BOTT: Longitudinal direction


11327 BOTT: Transverse direction
11327 TOP :
0.200
2.63
BOTT:
0.200
3.13

- Only minimum steel required.


- Only minimum steel required.
/
16
0.224
4.47 /
/
17
0.200
2.54 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
4.88 /
16
0.292
5.75 /
0.200
4.20 /
17
0.200
2.75 /

14
15

FY:
COVER
11329 TOP :
11329 BOTT:
11329 TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
0.200
4.03 /
17
0.215
4.29 /
0.200
4.85 /
16
0.203
4.07 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.70 /
15
0.200
0.200
1.07 /
14
0.200

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.24 /
16
0.200
0.200
0.29 /
17
0.200

required.
required.
required.
required.
3.55 /
1.17 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.29 /
16
0.200
0.59 /
0.200
0.22 /
17
0.226
4.50 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.09 /
15
0.200
0.52 /
0.200
0.67 /
14
0.215
4.30 /

15
14

11328
11328
11328
11328

11330
11330
11330
11330
11330

11331
11331
11331
11331
11331

11332
11332
11332
11332

11333
11333
11333
11333

FY:
COVER
11334 TOP :
11334 BOTT:
11334 TOP :

25.000 MM
required.
required.
required.
required.
3.64 /
2.98 /
25.000 MM

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.

11334 TOP :
BOTT:

11335
11335
11335
11335

11336
11336
11336
11336

11337
11337
11337
11337

11338
11338
11338
11338
11338

11339
11339
11339
11339
11339

11341
11341
11341
11341
11341

0.48 /
4.03 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.09 /
17
0.200
0.00 /
0.200
0.13 /
16
0.206
4.12 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.00 /
17
0.200
0.00 /
0.200
0.29 /
16
0.201
4.03 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.07 /
17
0.200
0.00 /
0.200
0.03 /
16
0.205
4.10 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.11 /
17
0.200
0.200
0.10 /
16
0.200

15
13

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.07 /
17
0.200
0.200
0.53 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.03 /
17
0.200
0.200
0.02 /
16
0.200

FY:
COVER
11342 TOP :
11342 BOTT:
11342 TOP :

0.200
0.200

0.06 /
0.12 /

15
14

0.200
0.202

25.000 MM
required.
required.
required.
required.
0.00 /
2.24 /
25.000 MM
required.
required.
required.
required.
0.00 /
2.17 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
2.12 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.

15
14

11342 BOTT: Transverse direction


- Only minimum steel required.
11342 TOP :
0.200
0.92 /
16
0.200
2.42 /
BOTT:
0.200
1.48 /
17
0.200
0.64 /

11343
11343
11343
11343
11343

11344
11344
11344
11344
11344

11404
11404
11404
11404
11404

11405
11405
11405
11405
11405

11406
11406
11406
11406
11406

11407
11407
11407
11407
11407

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.61 /
17
0.200
0.200
0.84 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.42 /
17
0.200
0.200
1.25 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.28 /
17
0.200
0.200
1.44 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.71 /
16
0.200
0.200
0.61 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.62 /
16
0.200
0.200
1.26 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.12 /
16
0.200
0.200
0.10 /
17
0.200

16
17

25.000 MM
required.
required.
required.
required.
1.66 /
0.00 /

13
17

25.000 MM
required.
required.
required.
required.
3.36 /
0.00 /

17
17

25.000 MM
required.
required.
required.
required.
3.15 /
0.00 /

17
17

25.000 MM
required.
required.
required.
required.
2.50 /
0.00 /

13
17

25.000 MM
required.
required.
required.
required.
3.84 /
0.00 /

16
17

25.000 MM
required.
required.
required.
required.
0.00 /
1.75 /

16
13

11408
11408
11408
11408
11408

11409
11409
11409
11409
11409

11410
11410
11410
11410

11411
11411
11411
11411
11411

11412
11412
11412
11412

11413
11413
11413
11413

11414
11414
11414
11414

COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

(BOTTOM):
25.000 MM
Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
0.12
0.200
0.46

TH:
100.000 MM
- Only minimum steel
- Only minimum steel
- Only minimum steel
- Only minimum steel
/
16
0.200
/
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.03 /
16
0.200
0.200
0.01 /
17
0.200

required.
required.
required.
required.
0.00 /
1.60 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.10 /
16
0.200
0.00 /
0.200
0.10 /
17
0.203
4.06 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
16
0.200
0.200
0.26 /
17
0.200

required.
required.
required.
required.
0.00 /
3.98 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.10 /
16
0.200
0.00 /
0.200
0.04 /
17
0.202
4.04 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.32 /
17
0.200
0.11 /
0.200
0.25 /
16
0.247
4.90 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.11 /
15
0.200
0.03 /
0.200
0.58 /
14
0.237
4.72 /

15
14

FY:

411.997 MPA FC:

24.525 MPA COVER (TOP):

required.
required.
required.
required.
0.00 /
1.66 /

16
13

25.000 MM

25.000 MM

25.000 MM

11415
11415
11415
11415

11416
11416
11416
11416

11417
11417
11417
11417
11417

11418
11418
11418
11418
11418

11419
11419
11419
11419
11419

11420
11420
11420
11420
11420

11421
11421
11421
11421

COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

(BOTTOM):
25.000 MM
Longitudinal direction
Longitudinal direction
Transverse direction
0.200
0.08
0.200
0.11

TH:
100.000 MM
- Only minimum steel required.
- Only minimum steel required.
- Only minimum steel required.
/
17
0.200
0.00 /
/
16
0.225
4.48 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
3.74 /
16
0.200
3.60 /
0.200
4.35 /
17
0.244
4.84 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.71 /
15
0.200
0.200
1.00 /
14
0.200

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.62 /
13
0.200
0.200
0.00 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.40 /
17
0.200
0.200
0.31 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.84 /
17
0.200
0.200
1.97 /
16
0.200

required.
required.
required.
required.
2.24 /
1.39 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
4.79 /
17
0.303
5.95 /
0.200
3.64 /
16
0.200
3.30 /

14
15

25.000 MM
required.
required.
required.
required.
3.01 /
3.74 /
25.000 MM
required.
required.
required.
required.
2.71 /
2.18 /

15
14

25.000 MM
required.
required.
required.
required.
1.56 /
1.13 /

16
17

25.000 MM

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.37 /
17
0.200
0.200
1.58 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.20 /
17
0.200
0.200
2.63 /
16
0.200

required.
required.
required.
required.
1.58 /
0.80 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
2.82 /
17
0.242
4.80 /
0.200
3.05 /
16
0.200
2.71 /

14
15

FY:
COVER
11425 TOP :
11425 BOTT:
11425 TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.201
4.96 /
17
0.200
3.10 /
0.279
6.82 /
16
0.200
1.81 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.18 /
17
0.200
0.200
4.00 /
16
0.200

required.
required.
required.
required.
1.35 /
0.43 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.97 /
17
0.222
4.42 /
0.200
2.07 /
16
0.200
2.46 /

14
15

FY:
COVER
TOP :
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
2.57 /
15
0.200
3.10 /
0.333
8.07 /
14
0.200
2.44 /

15
14

FY:

411.997 MPA FC:

11422
11422
11422
11422
11422

11423
11423
11423
11423
11423

11424
11424
11424
11424

11426
11426
11426
11426
11426

11427
11427
11427
11427

11428
11428
11428
11428

24.525 MPA COVER (TOP):

25.000 MM
required.
required.
required.
required.
2.86 /
1.43 /

15
14

25.000 MM

25.000 MM

25.000 MM

COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

(BOTTOM):
25.000 MM
Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
0.59
0.200
2.97

required.
required.
required.
required.
1.47 /
0.42 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.00 /
15
0.223
4.45 /
0.200
1.31 /
14
0.200
2.41 /

14
15

FY:
COVER
11431 TOP :
11431 BOTT:
11431 TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.207
5.12 /
16
0.200
2.82 /
0.284
6.93 /
17
0.200
1.92 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.32 /
16
0.200
0.200
4.20 /
17
0.200

required.
required.
required.
required.
1.38 /
0.45 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.99 /
16
0.228
4.53 /
0.200
2.21 /
17
0.200
2.44 /

14
15

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.36 /
16
0.200
0.200
1.66 /
17
0.200

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.14 /
16
0.200
0.200
2.75 /
17
0.200

FY:

411.997 MPA FC:

11429
11429
11429
11429
11429

11430
11430
11430
11430

11432
11432
11432
11432
11432

11433
11433
11433
11433

11434
11434
11434
11434
11434

11435
11435
11435
11435
11435

TH:
100.000 MM
- Only minimum steel
- Only minimum steel
- Only minimum steel
- Only minimum steel
/
15
0.200
/
14
0.200

24.525 MPA COVER (TOP):

25.000 MM

25.000 MM
required.
required.
required.
required.
2.54 /
1.62 /
25.000 MM
required.
required.
required.
required.
1.69 /
0.82 /
25.000 MM

14
15

COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

(BOTTOM):
25.000 MM
Longitudinal direction
Longitudinal direction
Transverse direction
0.200
2.75
0.200
3.21

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.16 /
16
0.200
0.200
0.42 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.75 /
16
0.200
0.200
2.04 /
17
0.200

required.
required.
required.
required.
2.45 /
1.33 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
4.72 /
16
0.336
6.56 /
0.200
3.76 /
17
0.200
3.03 /

14
15

FY:
COVER
11465 TOP :
11465 BOTT:
11465 TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
0.200
3.70 /
17
0.204
4.09 /
0.200
4.40 /
16
0.231
4.59 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.67 /
15
0.200
0.200
1.01 /
14
0.200

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.83 /
13
0.200
0.200
0.00 /
14
0.200

FY:

411.997 MPA FC:

11436
11436
11436
11436

11437
11437
11437
11437
11437

11438
11438
11438
11438
11438

11439
11439
11439
11439

11466
11466
11466
11466
11466

11467
11467
11467
11467
11467

TH:
100.000 MM
- Only minimum steel required.
- Only minimum steel required.
- Only minimum steel required.
/
16
0.258
5.11 /
/
17
0.200
2.61 /

24.525 MPA COVER (TOP):

14
15

25.000 MM
required.
required.
required.
required.
1.36 /
1.31 /

17
16

25.000 MM

25.000 MM
required.
required.
required.
required.
3.60 /
3.40 /
25.000 MM
required.
required.
required.
required.
3.71 /
1.61 /
25.000 MM

15
14

11468
11468
11468
11468

11469
11469
11469
11469

11470
11470
11470
11470

11471
11471
11471
11471

11472
11472
11472
11472

11473
11473
11473
11473

11474
11474
11474
11474
11474

COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

(BOTTOM):
25.000 MM
Longitudinal direction
Longitudinal direction
Transverse direction
0.200
0.28
0.200
0.24

TH:
100.000 MM
- Only minimum steel required.
- Only minimum steel required.
- Only minimum steel required.
/
16
0.200
0.50 /
/
17
0.238
4.72 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.07 /
15
0.200
0.46 /
0.200
0.62 /
14
0.227
4.52 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.06 /
16
0.200
0.46 /
0.200
0.13 /
17
0.213
4.24 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.08 /
17
0.200
0.00 /
0.200
0.11 /
16
0.205
4.10 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.00 /
17
0.200
0.00 /
0.200
0.27 /
16
0.200
4.01 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.09 /
17
0.200
0.00 /
0.200
0.03 /
16
0.204
4.08 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.12 /
17
0.200
0.200
0.09 /
16
0.200

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
2.14 /

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
25.000 MM
COVER (BOTTOM):
25.000 MM TH:
100.000 MM
11475 TOP : Longitudinal direction - Only minimum steel required.

11475
11475
11475
11475

11476
11476
11476
11476
11476

11477
11477
11477
11477
11477

11478
11478
11478
11478
11478

11479
11479
11479
11479
11479

11540
11540
11540
11540
11540

11541
11541
11541
11541
11541

BOTT: Longitudinal direction


TOP : Transverse direction
BOTT: Transverse direction
TOP :
0.200
0.05
BOTT:
0.200
0.48

- Only minimum steel required.


- Only minimum steel required.
- Only minimum steel required.
/
17
0.200
0.00 /
/
16
0.200
2.03 /

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
15
0.200
0.200
0.01 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.84 /
16
0.200
0.200
1.34 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.55 /
17
0.200
0.200
0.70 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.29 /
17
0.200
0.200
1.02 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.87 /
17
0.200
0.200
1.18 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.71 /
16
0.200
0.200
0.65 /
17
0.200

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.88 /

15
13

25.000 MM
required.
required.
required.
required.
2.24 /
0.00 /

16
13

25.000 MM
required.
required.
required.
required.
1.88 /
0.00 /

13
13

25.000 MM
required.
required.
required.
required.
3.19 /
0.00 /

17
13

25.000 MM
required.
required.
required.
required.
2.69 /
0.00 /

17
13

25.000 MM
required.
required.
required.
required.
2.36 /
0.00 /

13
13

11542
11542
11542
11542
11542

11543
11543
11543
11543
11543

11544
11544
11544
11544
11544

11545
11545
11545
11545
11545

11546
11546
11546
11546
11546

11547
11547
11547
11547
11547

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.37 /
16
0.200
0.200
0.94 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.11 /
16
0.200
0.200
0.08 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.11 /
16
0.200
0.200
0.47 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.04 /
16
0.200
0.200
0.03 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.09 /
16
0.200
0.200
0.10 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
16
0.200
0.200
0.26 /
17
0.200

FY:
COVER
11548 TOP :
11548 BOTT:

25.000 MM
required.
required.
required.
required.
3.71 /
0.00 /

16
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.85 /

16
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.76 /

16
14

25.000 MM
required.
required.
required.
required.
0.00 /
1.70 /

16
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.99 /

16
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.91 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.

16
14

11548 TOP : Transverse direction


11548 BOTT: Transverse direction
11548 TOP :
0.200
0.09
BOTT:
0.200
0.03

11549
11549
11549
11549

11550
11550
11550
11550

11551
11551
11551
11551

11552
11552
11552
11552

11553
11553
11553
11553
11553

11554
11554
11554
11554
11554

- Only minimum steel required.


- Only minimum steel required.
/
16
0.200
0.00 /
/
17
0.200
3.97 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.29 /
17
0.200
0.00 /
0.200
0.22 /
16
0.233
4.63 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.09 /
15
0.200
0.00 /
0.200
0.56 /
14
0.224
4.47 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.06 /
15
0.200
0.00 /
0.200
0.10 /
14
0.213
4.25 /

16
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
3.41 /
16
0.200
3.25 /
0.200
3.98 /
17
0.215
4.29 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.65 /
15
0.200
0.200
0.93 /
14
0.200

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.69 /
17
0.200
0.200
0.00 /
14
0.200

FY:
COVER
11555 TOP :
11555 BOTT:

25.000 MM
required.
required.
required.
required.
2.73 /
3.32 /
25.000 MM
required.
required.
required.
required.
2.53 /
1.85 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.

15
14

11555 TOP : Transverse direction


11555 BOTT: Transverse direction
11555 TOP :
0.200
1.38
BOTT:
0.200
0.33

11556
11556
11556
11556
11556

11557
11557
11557
11557

11558
11558
11558
11558

11559
11559
11559
11559

11560
11560
11560
11560
11560

11561
11561
11561
11561
11561

- Only minimum steel required.


- Only minimum steel required.
/
17
0.200
1.48 /
/
16
0.200
1.01 /

16
17

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.15 /
17
0.200
0.200
1.38 /
16
0.200

25.000 MM
required.
required.
required.
required.
2.60 /
1.15 /

15
14

FY:
COVER
TOP :
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
4.11 /
17
0.200
2.85 /
0.243
5.97 /
16
0.200
1.55 /

15
14

FY:
COVER
TOP :
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
2.02 /
15
0.200
2.82 /
0.305
7.43 /
14
0.200
2.06 /

15
14

FY:
COVER
TOP :
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
4.70 /
16
0.200
2.58 /
0.262
6.43 /
17
0.200
1.51 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.26 /
16
0.200
0.200
1.49 /
17
0.200

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.91 /
16
0.200
0.200
0.12 /
17
0.200

25.000 MM
required.
required.
required.
required.
2.38 /
1.33 /
25.000 MM
required.
required.
required.
required.
1.26 /
1.13 /

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
25.000 MM
COVER (BOTTOM):
25.000 MM TH:
100.000 MM
11562 TOP : Longitudinal direction - Only minimum steel required.

15
14

11562
11562
11562
11562

11563
11563
11563
11563
11563

11564
11564
11564
11564
11564

11565
11565
11565
11565
11565

11566
11566
11566
11566
11566

11567
11567
11567
11567
11567

11568
11568
11568
11568
11568

BOTT: Longitudinal direction


TOP : Transverse direction
BOTT: Transverse direction
TOP :
0.200
2.66
BOTT:
0.200
1.83

- Only minimum steel required.


- Only minimum steel required.
- Only minimum steel required.
/
17
0.200
2.07 /
/
16
0.200
1.17 /

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.90 /
17
0.200
0.200
2.36 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.69 /
17
0.200
0.200
3.50 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.40 /
15
0.200
0.200
2.75 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.14 /
16
0.200
0.200
3.95 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.94 /
16
0.200
0.200
2.47 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.45 /
16
0.200
0.200
1.67 /
17
0.200

14
15

25.000 MM
required.
required.
required.
required.
1.47 /
0.65 /

14
15

25.000 MM
required.
required.
required.
required.
1.29 /
0.32 /

14
15

25.000 MM
required.
required.
required.
required.
1.40 /
0.30 /

14
15

25.000 MM
required.
required.
required.
required.
1.33 /
0.32 /

14
15

25.000 MM
required.
required.
required.
required.
1.61 /
0.66 /

14
15

25.000 MM
required.
required.
required.
required.
2.27 /
1.08 /

14
15

11570
11570
11570
11570

11571
11571
11571
11571

11572
11572
11572
11572

11573
11573
11573
11573

11574
11574
11574
11574

11575
11575
11575
11575

11601
11601
11601
11601

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
2.51 /
17
0.218
4.36 /
0.200
2.77 /
16
0.200
2.24 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.77 /
17
0.202
4.04 /
0.200
1.88 /
16
0.200
2.04 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.00 /
17
0.205
4.10 /
0.200
1.22 /
14
0.200
2.02 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.89 /
16
0.210
4.20 /
0.200
2.04 /
17
0.200
2.05 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
2.48 /
16
0.241
4.78 /
0.200
2.85 /
17
0.200
2.19 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
4.30 /
16
0.313
6.13 /
0.200
3.22 /
17
0.200
2.50 /

14
15

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
3.16 /
17
0.200
3.53 /
0.200
3.86 /
16
0.203
4.06 /

15
14

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
COVER (BOTTOM):
25.000 MM TH:
100.000 MM

25.000 MM

11602
11602
11602
11602
11602

11603
11603
11603
11603
11603

11604
11604
11604
11604

11605
11605
11605
11605

11606
11606
11606
11606
11606

11607
11607
11607
11607
11607

11608
11608
11608
11608
11608

TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
0.55
0.200
0.90

/
/

Only
Only
Only
Only
15
14

minimum steel
minimum steel
minimum steel
minimum steel
0.200
0.200

required.
required.
required.
required.
3.15 /
2.96 /

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.81 /
13
0.200
0.200
0.00 /
14
0.200

required.
required.
required.
required.
3.35 /
1.26 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.25 /
16
0.200
0.15 /
0.200
0.21 /
17
0.219
4.38 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.02 /
15
0.200
0.12 /
0.200
0.57 /
14
0.210
4.19 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.06 /
16
0.200
0.200
0.12 /
17
0.200

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.07 /
17
0.200
0.200
0.10 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.25 /
16
0.200

15
14

25.000 MM

25.000 MM
required.
required.
required.
required.
0.13 /
3.92 /
25.000 MM
required.
required.
required.
required.
0.00 /
3.88 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.79 /

15
14

11609
11609
11609
11609
11609

11610
11610
11610
11610
11610

11611
11611
11611
11611
11611

11612
11612
11612
11612
11612

11613
11613
11613
11613
11613

11614
11614
11614
11614
11614

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.08 /
17
0.200
0.200
0.02 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.11 /
17
0.200
0.200
0.08 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.01 /
17
0.200
0.200
0.43 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
15
0.200
0.200
0.01 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.67 /
16
0.200
0.200
1.14 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.46 /
17
0.200
0.200
0.59 /
16
0.200

FY:
COVER
11615 TOP :
11615 BOTT:
11615 TOP :

25.000 MM
required.
required.
required.
required.
0.00 /
3.85 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
2.13 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
2.02 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.87 /

15
13

25.000 MM
required.
required.
required.
required.
2.04 /
0.00 /

14
13

25.000 MM
required.
required.
required.
required.
1.89 /
0.00 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.

13
13

11615 BOTT: Transverse direction


- Only minimum steel required.
11615 TOP :
0.200
2.02 /
17
0.200
3.06 /
BOTT:
0.200
0.75 /
16
0.200
0.00 /

11674
11674
11674
11674
11674

11675
11675
11675
11675
11675

11676
11676
11676
11676
11676

11677
11677
11677
11677
11677

11678
11678
11678
11678
11678

11679
11679
11679
11679
11679

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.70 /
17
0.200
0.200
1.02 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.55 /
16
0.200
0.200
0.50 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.03 /
16
0.200
0.200
0.61 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.09 /
16
0.200
0.200
0.06 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.05 /
16
0.200
0.200
0.40 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.04 /
16
0.200
0.200
0.02 /
17
0.200

17
13

25.000 MM
required.
required.
required.
required.
2.50 /
0.00 /

17
13

25.000 MM
required.
required.
required.
required.
2.33 /
0.00 /

13
13

25.000 MM
required.
required.
required.
required.
3.51 /
0.00 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.87 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.76 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.66 /

13
14

11680
11680
11680
11680
11680

11681
11681
11681
11681
11681

11682
11682
11682
11682
11682

11683
11683
11683
11683

11684
11684
11684
11684

11685
11685
11685
11685
11685

11686
11686
11686
11686
11686

COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

(BOTTOM):
25.000 MM
Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
0.07
0.200
0.08

TH:
100.000 MM
- Only minimum steel
- Only minimum steel
- Only minimum steel
- Only minimum steel
/
16
0.200
/
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
16
0.200
0.200
0.24 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.08 /
16
0.200
0.200
0.01 /
17
0.200

required.
required.
required.
required.
0.00 /
3.77 /

13
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.24 /
17
0.200
0.00 /
0.200
0.17 /
16
0.211
4.22 /

13
14

FY:
COVER
TOP :
BOTT:
TOP :
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.03 /
15
0.200
0.00 /
0.200
0.51 /
14
0.204
4.08 /

13
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.04 /
15
0.200
0.200
0.08 /
14
0.200

13
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.75 /
16
0.200
0.200
3.33 /
17
0.200

required.
required.
required.
required.
0.00 /
3.78 /

13
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.71 /

13
14

25.000 MM

25.000 MM
required.
required.
required.
required.
0.00 /
3.88 /
25.000 MM
required.
required.
required.
required.
2.57 /
3.57 /

15
14

11687
11687
11687
11687
11687

11688
11688
11688
11688
11688

11689
11689
11689
11689
11689

11690
11690
11690
11690
11690

11691
11691
11691
11691

11692
11692
11692
11692
11692

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.51 /
15
0.200
0.200
0.79 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.77 /
17
0.200
0.200
0.00 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.31 /
17
0.200
0.200
0.26 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.35 /
17
0.200
0.200
1.54 /
16
0.200

required.
required.
required.
required.
1.72 /
0.85 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
3.81 /
17
0.227
4.51 /
0.200
2.76 /
16
0.200
1.87 /

14
15

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.85 /
17
0.200
0.200
1.08 /
16
0.200

15
14

FY:
COVER
11693 TOP :
11693 BOTT:
11693 TOP :

25.000 MM
required.
required.
required.
required.
2.19 /
2.74 /

15
14

25.000 MM
required.
required.
required.
required.
2.16 /
1.41 /

15
14

25.000 MM
required.
required.
required.
required.
1.27 /
0.81 /

16
17

25.000 MM

25.000 MM
required.
required.
required.
required.
2.19 /
0.78 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.

11693 BOTT: Transverse direction


- Only minimum steel required.
11693 TOP :
0.200
1.48 /
17
0.200
1.23 /
BOTT:
0.200
1.95 /
16
0.200
0.43 /

11694
11694
11694
11694
11694

11695
11695
11695
11695
11695

11696
11696
11696
11696
11696

11697
11697
11697
11697
11697

11698
11698
11698
11698

11699
11699
11699
11699
11699

14
15

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.06 /
17
0.200
0.200
2.35 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.91 /
17
0.200
0.200
4.77 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.04 /
17
0.200
0.200
2.86 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.50 /
17
0.200
0.200
1.61 /
16
0.200

required.
required.
required.
required.
3.40 /
1.42 /

14
15

FY:
COVER
TOP :
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
1.10 /
15
0.200
2.34 /
0.265
6.49 /
14
0.200
1.59 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.09 /
15
0.200
0.200
2.43 /
14
0.200

14
15

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
COVER (BOTTOM):
25.000 MM TH:
100.000 MM

25.000 MM
required.
required.
required.
required.
3.64 /
1.55 /

14
15

25.000 MM
required.
required.
required.
required.
2.42 /
1.16 /

15
14

25.000 MM
required.
required.
required.
required.
1.11 /
0.16 /

14
15

25.000 MM

25.000 MM
required.
required.
required.
required.
1.23 /
0.13 /
25.000 MM

11700
11700
11700
11700
11700

11701
11701
11701
11701

11702
11702
11702
11702
11702

11703
11703
11703
11703
11703

11704
11704
11704
11704
11704

11705
11705
11705
11705
11705

11706
11706
11706
11706

TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
0.00
0.200
1.11

/
/

Only
Only
Only
Only
15
14

minimum steel
minimum steel
minimum steel
minimum steel
0.200
0.200

required.
required.
required.
required.
3.48 /
1.41 /

14
15

FY:
COVER
TOP :
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
3.79 /
16
0.200
2.17 /
0.224
5.52 /
17
0.200
1.08 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.71 /
16
0.200
0.200
3.50 /
17
0.200

14
15

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.68 /
16
0.200
0.200
1.82 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.01 /
16
0.200
0.200
1.24 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.57 /
16
0.200
0.200
2.08 /
17
0.200

required.
required.
required.
required.
1.39 /
0.44 /

14
15

FY:
COVER
TOP :
BOTT:
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
2.06 /
16
0.206
4.13 /
0.200
2.39 /
17
0.200
1.53 /

14
15

25.000 MM
required.
required.
required.
required.
1.16 /
0.15 /
25.000 MM
required.
required.
required.
required.
3.60 /
1.45 /

14
15

25.000 MM
required.
required.
required.
required.
2.04 /
0.98 /

15
14

25.000 MM

11707
11707
11707
11707
11707

11708
11708
11708
11708
11708

11730
11730
11730
11730
11730

11731
11731
11731
11731
11731

11732
11732
11732
11732
11732

11733
11733
11733
11733
11733

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.62 /
16
0.200
0.200
0.00 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.02 /
16
0.200
0.200
1.22 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.36 /
17
0.200
0.200
3.06 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.38 /
15
0.200
0.200
0.73 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.80 /
13
0.200
0.200
0.00 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.20 /
16
0.200
0.200
0.16 /
17
0.200

FY:
COVER
11734 TOP :
11734 BOTT:
11734 TOP :

25.000 MM
required.
required.
required.
required.
1.05 /
0.93 /

15
14

25.000 MM
required.
required.
required.
required.
1.94 /
0.75 /

14
15

25.000 MM
required.
required.
required.
required.
2.72 /
3.29 /

15
14

25.000 MM
required.
required.
required.
required.
2.49 /
2.34 /

15
14

25.000 MM
required.
required.
required.
required.
2.84 /
0.82 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.89 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.

15
14

11734 BOTT: Transverse direction


- Only minimum steel required.
11734 TOP :
0.200
0.00 /
16
0.200
0.00 /
BOTT:
0.200
0.50 /
14
0.200
3.73 /

11735
11735
11735
11735
11735

11736
11736
11736
11736
11736

11737
11737
11737
11737
11737

11738
11738
11738
11738
11738

11739
11739
11739
11739
11739

11740
11740
11740
11740
11740

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.05 /
16
0.200
0.200
0.12 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.04 /
17
0.200
0.200
0.07 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.22 /
13
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.07 /
17
0.200
0.200
0.01 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.08 /
17
0.200
0.200
0.05 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.34 /
16
0.200

FY:

411.997 MPA FC:

24.525 MPA COVER (TOP):

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.49 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.66 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
3.57 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
3.64 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
2.10 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
2.00 /
25.000 MM

15
13

11741
11741
11741
11741
11741

11742
11742
11742
11742
11742

11743
11743
11743
11743
11743

11744
11744
11744
11744
11744

11808
11808
11808
11808
11808

11809
11809
11809
11809
11809

11810
11810
11810
11810

COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

(BOTTOM):
25.000 MM
Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
0.01
0.200
0.02

TH:
100.000 MM
- Only minimum steel
- Only minimum steel
- Only minimum steel
- Only minimum steel
/
16
0.200
/
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.55 /
16
0.200
0.200
1.00 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.21 /
17
0.200
0.200
0.36 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.63 /
17
0.200
0.200
0.39 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.44 /
17
0.200
0.200
0.83 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.34 /
16
0.200
0.200
0.34 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel

required.
required.
required.
required.
0.00 /
1.85 /

15
13

25.000 MM
required.
required.
required.
required.
1.97 /
0.00 /

14
13

25.000 MM
required.
required.
required.
required.
1.93 /
0.00 /

13
13

25.000 MM
required.
required.
required.
required.
3.05 /
0.00 /

13
13

25.000 MM
required.
required.
required.
required.
2.29 /
0.00 /

17
13

25.000 MM
required.
required.
required.
required.
2.28 /
0.00 /
25.000 MM
required.
required.
required.
required.

13
13

11810 TOP :
BOTT:

11811
11811
11811
11811
11811

11812
11812
11812
11812
11812

11813
11813
11813
11813
11813

11814
11814
11814
11814
11814

11815
11815
11815
11815
11815

11816
11816
11816
11816
11816

0.200
0.200

1.61 /
0.20 /

16
17

0.200
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.05 /
16
0.200
0.200
0.03 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
16
0.200
0.200
0.33 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.04 /
16
0.200
0.200
0.02 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.05 /
16
0.200
0.200
0.06 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
16
0.200
0.200
0.21 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.05 /
16
0.200
0.200
0.00 /
17
0.200

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
COVER (BOTTOM):
25.000 MM TH:
100.000 MM

3.52 /
0.00 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.88 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.77 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.60 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
3.69 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
3.61 /

13
13

25.000 MM
required.
required.
required.
required.
0.00 /
3.68 /
25.000 MM

13
13

11817
11817
11817
11817
11817

11818
11818
11818
11818
11818

11819
11819
11819
11819
11819

11820
11820
11820
11820
11820

11821
11821
11821
11821
11821

11822
11822
11822
11822
11822

11823
11823
11823
11823
11823

TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
0.19
0.200
0.10

/
/

Only
Only
Only
Only
17
16

minimum steel
minimum steel
minimum steel
minimum steel
0.200
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.44 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.02 /
15
0.200
0.200
0.06 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.01 /
16
0.200
0.200
2.64 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.37 /
15
0.200
0.200
0.63 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.99 /
17
0.200
0.200
0.16 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.58 /
17
0.200

required.
required.
required.
required.
0.00 /
3.66 /

13
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.55 /

13
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.39 /

13
14

25.000 MM
required.
required.
required.
required.
1.93 /
2.69 /

16
17

25.000 MM
required.
required.
required.
required.
1.56 /
1.97 /

15
14

25.000 MM
required.
required.
required.
required.
1.67 /
0.87 /

15
14

25.000 MM
required.
required.
required.
required.
0.96 /

16

BOTT:

11824
11824
11824
11824
11824

11825
11825
11825
11825
11825

11826
11826
11826
11826
11826

11827
11827
11827
11827
11827

11828
11828
11828
11828
11828

11829
11829
11829
11829
11829

0.200

0.67 /

16

0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.26 /
17
0.200
0.200
1.64 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
3.28 /
17
0.200
0.200
2.57 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.44 /
17
0.200
0.200
0.66 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.94 /
17
0.200
0.200
1.52 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.53 /
17
0.200
0.200
2.07 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.96 /
17
0.200
0.200
2.63 /
16
0.200

0.42 /

17

25.000 MM
required.
required.
required.
required.
1.22 /
0.44 /

14
15

25.000 MM
required.
required.
required.
required.
3.26 /
0.98 /

14
15

25.000 MM
required.
required.
required.
required.
1.67 /
0.32 /

15
14

25.000 MM
required.
required.
required.
required.
0.88 /
0.25 /

14
15

25.000 MM
required.
required.
required.
required.
2.65 /
0.93 /

14
15

25.000 MM
required.
required.
required.
required.
2.25 /
1.30 /

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
25.000 MM
COVER (BOTTOM):
25.000 MM TH:
100.000 MM
11830 TOP : Longitudinal direction - Only minimum steel required.

16
17

11830
11830
11830
11830

11831
11831
11831
11831
11831

11832
11832
11832
11832

11833
11833
11833
11833
11833

11834
11834
11834
11834
11834

11835
11835
11835
11835
11835

11836
11836
11836
11836
11836

BOTT: Longitudinal direction


TOP : Transverse direction
BOTT: Transverse direction
TOP :
0.200
0.00
BOTT:
0.200
1.69

- Only minimum steel required.


- Only minimum steel required.
- Only minimum steel required.
/
17
0.200
0.88 /
/
16
0.200
0.10 /

14
15

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.03 /
17
0.200
0.200
1.26 /
16
0.200

25.000 MM
required.
required.
required.
required.
2.56 /
0.90 /

14
15

FY:
COVER
TOP :
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.
Transverse direction
- Only minimum steel required.
0.200
0.76 /
16
0.200
1.67 /
0.241
5.92 /
17
0.200
0.97 /

15
14

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
16
0.200
0.200
2.17 /
17
0.200

14
15

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
16
0.200
0.200
1.05 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
2.98 /
16
0.200
0.200
4.75 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.51 /
16
0.200
0.200
3.28 /
17
0.200

25.000 MM
required.
required.
required.
required.
1.01 /
0.09 /
25.000 MM
required.
required.
required.
required.
2.69 /
0.90 /

14
15

25.000 MM
required.
required.
required.
required.
1.75 /
0.47 /

15
14

25.000 MM
required.
required.
required.
required.
0.98 /
0.14 /

14
15

11837
11837
11837
11837
11837

11838
11838
11838
11838
11838

11839
11839
11839
11839
11839

11840
11840
11840
11840
11840

11841
11841
11841
11841
11841

11842
11842
11842
11842
11842

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.62 /
16
0.200
0.200
1.77 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.76 /
16
0.200
0.200
0.96 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.29 /
16
0.200
0.200
1.75 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.79 /
16
0.200
0.200
2.08 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.63 /
17
0.200
0.200
0.00 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.53 /
16
0.200
0.200
0.79 /
17
0.200

FY:
COVER
11843 TOP :
11843 BOTT:
11843 BOTT:

25.000 MM
required.
required.
required.
required.
2.84 /
0.94 /

14
15

25.000 MM
required.
required.
required.
required.
1.58 /
0.47 /

15
14

25.000 MM
required.
required.
required.
required.
1.20 /
0.39 /

14
15

25.000 MM
required.
required.
required.
required.
3.37 /
1.00 /

14
15

25.000 MM
required.
required.
required.
required.
0.86 /
0.84 /

17
16

25.000 MM
required.
required.
required.
required.
1.65 /
0.67 /

411.997 MPA FC:


24.525 MPA COVER (TOP):
25.000 MM
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel required.
Longitudinal direction - Only minimum steel required.
Transverse direction
- Only minimum steel required.

14
15

11843 TOP :
BOTT:

11864
11864
11864
11864
11864

11865
11865
11865
11865
11865

11866
11866
11866
11866
11866

11867
11867
11867
11867
11867

11868
11868
11868
11868
11868

11869
11869
11869
11869
11869

0.200
0.200

3.20 /
2.03 /

16
17

0.224
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
1.17 /
17
0.200
0.200
1.72 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.23 /
15
0.200
0.200
0.50 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.86 /
17
0.200
0.200
0.00 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.12 /
16
0.200
0.200
0.10 /
17
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
16
0.200
0.200
0.40 /
14
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.06 /
16
0.200
0.200
0.09 /
17
0.200

FY:
411.997 MPA FC:
24.525 MPA COVER (TOP):
COVER (BOTTOM):
25.000 MM TH:
100.000 MM

4.47 /
1.11 /

14
15

25.000 MM
required.
required.
required.
required.
1.66 /
2.33 /

15
14

25.000 MM
required.
required.
required.
required.
1.70 /
1.55 /

15
14

25.000 MM
required.
required.
required.
required.
2.26 /
0.27 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.25 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
3.12 /

15
14

25.000 MM
required.
required.
required.
required.
0.00 /
2.92 /
25.000 MM

15
14

11870
11870
11870
11870
11870

11871
11871
11871
11871
11871

11872
11872
11872
11872
11872

11873
11873
11873
11873
11873

11874
11874
11874
11874
11874

11875
11875
11875
11875
11875

11876
11876
11876
11876

TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

Longitudinal direction
Longitudinal direction
Transverse direction
Transverse direction
0.200
0.06
0.200
0.07

/
/

Only
Only
Only
Only
17
16

minimum steel
minimum steel
minimum steel
minimum steel
0.200
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.00 /
17
0.200
0.200
0.24 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.10 /
17
0.200
0.200
0.03 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.10 /
17
0.200
0.200
0.05 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.20 /
17
0.200
0.200
0.52 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel
0.200
0.02 /
17
0.200
0.200
0.02 /
16
0.200

FY:
COVER
TOP :
BOTT:
TOP :
BOTT:

411.997 MPA FC:


24.525 MPA COVER (TOP):
(BOTTOM):
25.000 MM TH:
100.000 MM
Longitudinal direction - Only minimum steel
Longitudinal direction - Only minimum steel
Transverse direction
- Only minimum steel
Transverse direction
- Only minimum steel

required.
required.
required.
required.
0.00 /
3.43 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
3.34 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
3.41 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.66 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.64 /

15
13

25.000 MM
required.
required.
required.
required.
0.00 /
1.55 /
25.000 MM
required.
required.
required.
required.

15
13

Anda mungkin juga menyukai