Anda di halaman 1dari 3

VII.

DATA PENGAMATAN
7.1 Aliran Fluida Lewat Venturimeter
H 2 H1

Q pengukuran

(m)

m s

m3

Q teoriitis

m s
3

Cv

Q pengukuran
Q teoritis

(koefisien venturi)

10 2

1,55.10 4

1.260

0.986

1,572.10 4

2.10 2

2,16.10 4

2.520

1.549.10 4

3.10 2

2,86.10 4

3.780

1,39
1,708

4.10 2

2,96.10 4

1.501.10 4

5.10 2

3,43.10 4

1,972
2,205

6.10 2

3,74.10 4

2,415
2,609

1.549.10 4

7.10 2

4,27.10 4

10.080

8.10 2

4,36.10 4

11.340

9.10 2

4,8.10 4

5.040
6.300
7.560
8.820

1,674.10 4
1.557.10 4
1.636.10 4

2,788
2,96

1.564.10 4
1.622.10 4

7.2 Aliran Fluida Lewat Pompa


H 2 H1
(m)

P .g

V 2 2.g

HHP

m s

(m)

(m)

(m)

(m)

(watt)

4.10 2
5.10

6.10

8,63.10 5
9,198.10

2.342.10

0,504
0,63
0,756
0,882

7.10 2

2.398.10 4

8.10 2

3,021.10 4

9.10 2

3.618.10 4 1,97
5.040.10 4

9.5.10 2

0,008
1,134

1.13.10 3
1.56.10

1.328.10

8,96.10 3
0.014
0,025
0,039

0,65

1,203

1,038

0,65

1,329

1,222

0,65

1,450

3,396

0,65

1,573

3,772

0,65

1,708

0,65

1,834

5,161
6,635

0,65

1,897

6,498

X. KESIMPULAN
a. Head total pompa semakin lama semakin bertambah, dapat dilihat dari
peningkatannya di dalam grafik H terhadap Q.
b. Daya hidrolik pompa (HHP) semakin lama semakin meningkat.

c. Dari grafik H terhadap Q dapat dilihat bahwa H (Head total pompa)


semakin lama semakin bertambah/meningkat.