Anda di halaman 1dari 7

Handover Parameters:

There are three ways of optimizing handovers in LTE:


a) Via the modification of the parameters a3offset and hysteresisa3
b) By changing the parameter timetotriggereventa3
c) Via the modification of the parameter filtercoefficient for event a3.
These set of blogs will dealt with parameter setting for Periodic Reporting of Event A3
only. The intention is to deal with each of the cases mentioned above, one at a time.
Hence, this blog will concentrate in case a).
Definitions:
Event A3 is defined as a triggering event when a neighbor cell becomes an offset better
than the serving cell. The UE creates a measurement report, populates the triggering
details and sends the message to the serving cell. The parameters that define the
trigger include:

a3offset: This parameter can be found in 3GPP 36.331. It configures the RRC IE
a3-Offset included in the IE reportConfigEUTRA in the
MeasurementConfiguration IE. The value sent over the RRC interface is twice
the value configured, that is, the UE has to divide the received value by 2.The
role of the offset in Event A3 is to make the serving cell look better than its
current measurement in comparison to the neighbor.

Hysteresisa3: The role of the hysteresis in Event A3 is to make the measured


neighbor look worse than measured to ensure it is really stronger before the UE
decides to send a measurement report to initiate a handover.

timetoTriggera3: The role of ttt in Event A3 is to avoid a Ping-Pong effect.

CellIndividualoffsetEutran: This parameter is applied individually to each


neighbor cell with load management purposes. The higher the value allocated to
a neighbor cell, the more attractive it will be. This parameter can only be used if
the neighbor list is broadcast in SIB4 or in an RRC connection reconfiguration.

Based on the picture above, event A3 will trigger when:


RSRP (target) > RSRP (Serving) +a3offset + hysteresisa3 cellindividualoffsetEutran
And this condition is valid for timetotriggera3.
At the expiration of timetotriggera3, if the UE does not receive an RRC connection
reconfiguration message (handover command) from the eNodeB, then it will start a
timer called reportingintervala3. At the expiration of this timer, if the conditions for
event A3 are still met and the eNodeB has not responded, then another measurement
report will be sent to the eNodeB. This process will continue until the eNodeB responds
or until a number of measurement reports given by the
parameter reportingamount have been sent.
Examples:
The table below assumes that cellindividualoffsetEutran is not used and shows when
the eventa3offset is triggered and when the UE ceases sending measurement reports.

As it can be seen from the table, eventa3 triggers at a3offset+hysteresisa3


However!!! After the first measurement result, subsequent measurement results can be
sent if the RSRP of the neighbor cell is only a3offset-hysterisisa3 dB stronger! Hence,
weaker neighbors could be reported in the measurements sent by the UE (this case is
very rare but it exists in real systems).
Therefore, it is recommended to follow the optimization rules:
a) A3offset should always be larger than hysteresisa3 if we want UE to handover to
cells with an RSRP at least equal to the RSRP value of its serving cell.
b) Ensuring a3offset > hysteresisa3 avoids ping-pongs
c) The higher the value of a3offset+hysteresisa3 the more we drag the calls to
neighboring cells. This is very useful where we have coverage holes (not a one to one
deployment scenario on top of 3G cells)
d) The smaller the value of a3offset+hysteresisa3 the faster we release the calls to
neighboring cells. This is useful in those scenarios where a large number of LTE cells
exists in a given geographical area.
e) The higher the value of a3offset+hysteresisa3 the more difficult we make it for calls
do handover to other cells.
Remember, eventa3 triggers at a3offset+hysteresisa3. Subsequent message reports
are sent when the RSRP of the neighbor cell is a3offset-hysteresisa3 (See figure
below).

In our next blog, we will discuss the parameter timetotriggera3, which is another tool for
optimizing handovers in LTE.
Time to Trigger Event a3
As explained in part 1 of these blogs, if the RSRP of a neighbor cell is a3offset+
hysteresisa3 dB stronger than the serving cell for a time period equal
to timetotriggera3 then the UE sends the first measurement report to the eNodeB
indicating that eventa3 has occurred. Timetotriggera3 typical values are [0, 40, 64, 80,
100, 128, 160, 256, 320, 480, 512, 640, 1024, 1280, 2560, 5120] milliseconds.
Clearly, the utilization of timetotriggera3 is highly dependent on the
parameters a3offset and hysteresisa3.However, some general troubleshooting
guidelines are provided here to minimize ping pong effects.
Rules:
a) If a3offset+ hysteresisa3 is relatively large (i.e.: 6dB or stronger), then a value
of timetotriggera3 under 100 ms is acceptable.
Explanation: Since the RSRP of the neighbor cell is already stronger than the value of
the source cell, the time to trigger should not be large.

b) If a3offset+ hysteresisa3 is relatively small (i.e.: 2dB), then a value


of timetotriggera3 should be around 320 to 640 ms.
Explanation: Since the RSRP of the neighbor cell is not much stronger than the value of
the source cell, the time to trigger should not large to ensure the value remains the
same for a long period of time.
c)

If a3offset = hysteresisa3, see b)

d)

If a3offset > hysteresisa3, see a)

e)

If a3offset < hysteresisa3, see a)

However, these recommendations depend much on the speed of the mobile and the
coverage scenarios.
The value allocated to timetotriggera3, hence, depends on:

Parameter setting of a3offset and hysteresisa3,

Morphology (dense urban, urban, suburban, rural)

Speed of UE in the cells (freeways and or suburban roads).

So far, we have discussed two methods for optimizing event A3. In out next blog we will
talk about the benefits of optimizing another parameter called, filtercoefficient for event
A3 that will allow us to eliminate some of the effects of fast fading in the UE
measurements.
Filter Coefficient for Event a3
Once the UE is configured to do measurements, the UE starts measuring reference
signals from the serving cell and any neighbors it detects. The next question is whether
the UE should look at just the current measurement value, or if the recent history of
measurements should be considered. LTE, like other wireless technologies, takes the
approach of filtering the currently measured value with recent history. Since the UE is
doing the measurement, the network conveys the filtering requirements to the UE in an
RRC Connection reconfiguration message.
The UE filters the measured result, before using for evaluation of reporting criteria or for
measurement reporting, by the following formula:

Where

Mn is the latest received measurement result from the physical layer;

Fn is the updated filtered measurement result, that is used for evaluation of


reporting criteria or for measurement reporting;

Fn-1 is the old filtered measurement result, where F0 is set to M1 when the first
measurement result from the physical layer is received; and

a = 1 / 2(k/4), where k is the filterCoefficent for the corresponding measurement


quantity received by the quantityConfig.

Then, the UE adapts the filter such that the time characteristics of the filter are
preserved at different input rates, observing that the filterCoefficent k assumes a
sample rate equal to 200 ms.
The parameter a defines the weight given to current value and (1-a) (i.e., the
remaining weight is given to the last filtered value). For example, if filter coefficient k = 4,
then a = ^ (4/4) =1/2. This means that new measurement has half the weight and the
last filtered measurement gets the other half of the weight.
Example of Filter coefficient values are:

Case 1: value k = 8 , a = , Fn = Old + New

Case 2: value k = 4, a = , Fn = Old + New

Optimization Rules:
a) A high value of the parameter filtercoefficient will provide higher weight to old
measurements (more stringent filter) (the opposite is true)
b) The higher the values of filtercoefficient the higher the chances of eliminating fast
fading effects on the measurement reports
1. This eliminates reporting a cell which RSRP was suddenly changed due to
multipath or fast fading

2. Which in turns eliminates the chances to handover to a cell which RSRP was
strong for some milliseconds
3. Therefore reducing the chances for Ping-Pong effects
c) A value of 8 is typically used in the network although a value of 16 might also be
used in dense urban areas.