KEY PLAN

SALEM TO ERUMAPALAYAM PANCHAYAT ROAAD

SITE PLAN:NOT TO SCALE

7.62M(25'0") WIDE B.T ROAD

PROPOSED
AREA

NOT TO SCALE

MILK
SOCIETY

56/2A2B

ANGLES
PURLINS

1.83
G.I. SHEET ROOF

0.11

AREA DEATILES:VENTILATOR

1.

SITE AREA

27007.20 S.FT

62.00 CENT
2509.05 S.M

2.

BUILDING AREA

2610.00 S.FT

1213.93 S.M

3.

TOILET AREA

82.93 S.FT

7.71 S.M

4.

SECURITY AREA

56.41 S.FT

5.24 S.M

5.

EB AREA

156.25 S.FT

14.52 S.M

6.

DINNING AREA

247.50 S.FT

23.00 S.M

7.

TOTAL AREA

3153.09 S.FT

292.93 S.M

8.

EXISTING BUILDING

230.88 S.FT

21.45 S.M

9.

VACANT AREA

23623.23 S.FT

2194.66 S.M

7.57
WINDOW

4.88

FLOORING P.C.C IN 1:4:8 MIX


SAND FILLING
EARTH FILLING

G.L

COLUMN FOOTING FOR BASEMENT


G.L

76.00

G.L

G.L

FRONT ELEVATION

G.L

FRONT ELEVATION

G.L

SECTION ON AA

2.21

AC SHEET ROOF
COLUMN FOOTING FOR FOUNDATION

40' [12.19]
9" [0.23]

9" [0.23]
8'-6" [2.59]

9" [0.23]

20' [6.10]

9" [0.23]
8'-6" [2.59]

9" [0.23]

1.37

2.90

1.37

FLOORING P.C.C IN 1:4:8 MIX


SAND FILLING

2.44

EARTH FILLING

0.46
G.L

8'6"X11'0"

STAGE
20'0"x16'0"
D1

INLET
CHAMBER

TOILET

TOILET
4'6"X4'7.5"

0.76
0.15
0.15

(NOT TO SCALE)

B.W. IN C.M
P.C.C 1:5:10
SAND FILLING

0.23
SAND FILLING

SECTION

SIZE IN M

ROLLING SHUTTER- R.S

3.05 X 3.05

WINDOW - W

1.22 X 1.36

DOOR - D

1.52 X 2.14

DOOR- D1

0.69 X 2.14

VENTILATOR

0.60 X 0.60

W2.29

ENGINEER:

6'0' X 6'0'
D1

1.52

10' [3.05]
9" [0.23]

SECURITY

2.291.83

0.11 0.11

2.29

PLAN
GL

GL

ELEVATION

0.15

R.S
W

10' [3.05]
9" [0.23]

38'6" X 47'0"

DESCRIPTION

OFFICE USE ONLY

SECTION

SCALE :-

10' [3.05]
9" [0.23]

R.S

63'-9" [19.43]

HALL

0.23
S.NO

ALL DIMENSIONS ARE IN

BOUNDRY SHOWN IN G.L

BUILDING SHOWN IN -

FEET & METER

ROAD SHOWN IN

SCALE 1 : 100 OR 1" = 8'0"

G.L

FRONT ELEVATION

AC SHEET ROOF

0.61

9" [0.23]

10' [3.05]
9" [0.23]

AC SHEET ROOF

2.90

BRICK WORK IN C.M

0.61

BRICK WORK IN C.M

2.44

FLOORING P.C.C IN 1:4:8 MIX


SAND FILLING
EARTH FILLING

PLAN
AC SHEET ROOF

0.61

FLOORING P.C.C IN 1:4:8 MIX


SAND FILLING

2.44

G.L

EARTH FILLING
G.L

0.46
G.L

G.L

G.L

0.76

FRONT ELEVATION
3.89
0.23
0.11 0.11
1.07 1.07 1.07

0.23
1.981.75
0.23

0.15
0.15

0.23

0.23

B
TOILET TOILET BATH
3'6"X5'0" 3'6"X5'0" 3'6"X5'0"

1.98

R.R.MASONRY FOR FOUNDATION


P.C.C FOR FOUNDATION 1:5:10 MIX
SAND FILLING FOR FOUNDATION

SECTION ON - BB

D1

R.R.MASONRY FOR BASEMENT


R.R.MASONRY FOR FOUNDATION
P.C.C FOR FOUNDATION 1:5:10 MIX
SAND FILLING FOR FOUNDATION

0.76
0.15
0.15
1.14
0.23
0.46

0.15

SECTION ON - DD

1.14

R.R.MASONRY FOR BASEMENT

0.23

3.81

0.23

3.35

SECTION ON - EE
0.23

22'-6" [6.86]

E
DINNING
22'6" X 11'0"

3.81
3.35

0.23
D1

G.L

0.76

FLOORING P.C.C IN 1:4:8 MIX


EARTH FILLING
R.R.MASONRY FOR BASEMENT

1.14

0.46

G.L

0.46

R.R.MASONRY FOR FOUNDATION


P.C.C FOR FOUNDATION 1:5:10 MIX
SAND FILLING FOR FOUNDATION

0.76

0.46
G.L

11' [3.35]

2.90

BRICK WORK IN C.M

2.59
0.15 0.15
0.15
0.76 0.76
2.44

R.S
40' [12.19]

D1

G.L

G.L

FRONT ELEVATION

3.89

PLAN

AREA OF SITE

314.38 S.M
2509.05 S.M

Mrs.SHENBAGAM,W/O Mr.CHITHANANTHAM

(NOT TO SCALE)

JOINERY DETAILS :-

BUILD UP AREA+ EXISTING AREA

APPLICANT:

0.23

0.23

COMPOUND WALL DETAILS :

2.29
1.83

PLAN

PLOT
COVERAGE [ PC]

0.46
SECTION
ON - CC

150 mm - 300 mm Dia


Bore well.

OUT LET CHAMBER

10.

0.23

Recharge Pit with Bore Holes

LONGITUDINAL SECTION

1.14

Perforated Concrete Slab


Sand & Brick Bats

6'0"[1.83]

INLET
CHAMBER

R.R.MASONRY FOR FOUNDATION


P.C.C FOR FOUNDATION 1:5:10 MIX
SAND FILLING FOR FOUNDATION

CONSERVATION OF RAIN WATER

VENT PIPE
R.C.C SLAB
MAN HOLE
OUT LET LOOSE JOINT
CHAMBER
SW PIPE

(NOT TO SCALE)

D1

4'6"X4'7.5"

G.L

0.60 0.30

8'6"X11'0"

10' [3.05]
9" [0.23]
9" [0.23]

ROOM

R.R.MASONRY FOR BASEMENT

0.76

SEPTIC TANK:

10' [3.05]
9" [0.23]

ROOM

65'-3" [19.89]

BRICK WORK IN C.M

P.C.C FOR FOUNDATION 1:5:10 MIX


SAND FILLING FOR FOUNDATION

46.00
23.00
15.00
15.00

E.B ROOM
11'0" X 11'0"

RS

3.81

PLAN

3.81

= 0.12529 X 100 = 12.52%