Anda di halaman 1dari 2

DIESEL GENSET 2500kVA (Standby Power)

TNK2250M
2250kVA
50Hz

Specification, picture, dimension may change without notice due to product improvement.

Engine Specs
Type
Power Output Gens. [kW]
Electrical Output Gens. [kVA]
Speed [Rpm] / Frequency [Hz]
No of cylinders
Displacement [l]
Bore/Stroke [mm]
Injection
Compression Ratio
Governor
Cooling System
Fuel Consumption [l/h]
Oil Capacity [l]

:
:
:
:
:
:
:
:

MTU 16V 4000 G63


2000
2500
1500 / 50
16V
76.3
170 / 210
Common Rail System with electronically controlled
high pressure injection.
: 16.5 : 1
: Electronic Engine Management System ADEC
: Water cooling with Radiator
: 502.4 (Standby, 100% Load)
: 300 (initial filling)

Alternator Specs
Type [3 Phases, Single Bearing]
Rated Output [kVA]
Speed [Rpm] / Frequency [Hz]
Voltage [V]
Insulation
Protection

: LEROY SOMER LSA51.2 VL90 (or equivalent)


: 2500
: 1500 / 50
: 400, 6300, 6600
: Class H
: IP 23

Accessories
Radiator Cooling
Coolant Capacity [l]
Digital Control Panel, consist of

System Volt.
Exhaust System
Baseframe
Engine and Alternator Mounting
Air Filters
Set of Operation books, consist of

:as MTU standard


: 210 (engine only)
: DEEP SEA ELECTRONICS (DSE 7320 or depend
on request) Module, parameter : Volt meter,
Auto Start Control (AMF), Hour meter,
Speed Control,
Engine lube oil pressure gauge, Engine coolant
Temperature gauge) ,
: Ampere meter
: Start key switch
: Charging control lamp
: Control fuse
: Emergency Stop Button
: 24Volts, 4 x 200 (Filled)
: Set of Connection cables and Cable terminals
: Industrial exhaust silencer
: Flexible Hose (compensator for the exhaust pipe)
: Steel Channel construction
: Rubber metal elements
: Dry Type
: Engine operating instruction
: Certificate of Origin
: Alternator operating instruction
: Genset Test Report

Genset Dimension and Weight


Dimension Approx. [mm]
Dry Weight Approx. [kg]

: 6500 x 2200 x 2750


: 13950

PT. Tan Energy Indonesia (TANEKO)


Jl. Prof, DR. Latumenten kav.50
Sentra Latumenten blok. D2, Jakarta 11460
Telp
: 62-21 569 58610-14
Email
: marketing@taneko.co.id
Website
: www.taneko.co.id

According to ISO 8528-5. Continuous Power: No time limitation, plus 10% addictional, power for governing purpose only. Prime Power: Average output 80%, no time limitation, plus 5%
addictional power for governing purpose only. Limited Time Running Power: for up to 500 h/year, thereof a maximum of 300 h/year continuous running. In consideration of a generator
efficiency level of 89% - 90% and a power factor of 0.8

Anda mungkin juga menyukai