SOP for EH Oil system Start-up

1)
2)
3)
4)

Ensure Level of EH oil tank is normal.(>500 mm)


Ensure CCCW is running and cooling water line is charged.
Ensure filter is in line and Oil temp. >20C.
Check AOP, JOP, Turning gear, vapour extraction fan and HP start up
pump are in service.
5) Start EH oil pump and put another in standby.
6) Check discharge Pr. (140 Ksc).Maintain it through recirculation line.
7) Check if any leakage in line.
8) Start regenerative pump for filtration.
9) Check current.
10) Keep watch on oil temp.
11) Check weather circulation pump starts or not on high oil temp.
12) Check weather circulation pump starts or not on high oil temp.
(45C)
13) Check Circulation pump Stopped or not on oil temp.(35C)
14) Ensure oil heater is cut off on normal oil temp.
15) Start oil centrifuge and vapour extraction fan.